Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INJECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Experimental and simulated heating in nanocrystalline diamond charge exchange injection films using an electron beam to mimic SNS conditions

Nanocrystalline diamond (NCD) foils have been in use at the Spallation Neutron Source as primary stripper foils for charge exchange injection since the machine’s inception. NCD’s low atomic number leads to reduced beam scattering while still being easy to handle, as opposed to even lighter elements. NCD foils also have the benefit of being free-standing, and rigid when grown under the right conditions to minimize residual stresses. This study overviews a method to mimic the Spallation Neutron Source (SNS) beam and characterize thermally driven failure of NCD foils. To do this, a foil test stand was developed with in situ diagnostics that tracks signs of foil sublimation and thinning. The foil test stand’s electron beam is equated to the SNS beamline by comparing peak deposited energy densities for both beams. Post-mortem testing is also conducted to help elucidate changes the NCD foils undergo during exposure to the beam. Further, a COMSOL simulation was also developed as a method to assess potential future changes to the NCD film and predict how changes to beam conditions will effect foil temperatures. This method allows for examination of the NCD foil’s thermal limits and can be used to assess future changes to SNS stripper foils.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bronchopulmonary C-fibers' IL1RI contributes to the prolonged apneic response to intra-atrial injection of capsaicin by prenatal nicotinic exposure in rat pups

Prenatal nicotinic exposure (PNE) as a SIDS model reportedly sensitizes bronchopulmonary C-fibers (PCFs), contributing to the prolonged PCF-mediated apnea in rat pups, but the relevant mechanisms are not fully understood. Pulmonary IL-1β upregulated by cigarette smoke is known to stimulate or sensitize PCFs acting via IL-1 type I receptor (IL1RI) and inhibit inspiration frequency. Because of its upregulation observed in SIDS victims, we hypothesized that PNE increased pulmonary IL-1β release and IL1RI expression in pulmonary C-neurons via action on α7 nicotinic acetylcholine receptors (α7nAChR) to induce the prolonged PCF-mediated apnea. IL-1β in BALF and IL1RI in the nodose/jugular (N/J) ganglion and vagal pulmonary C-neurons retrogradely-traced were compared between Ctrl (saline) and PNE pups and among the vehicle-treated Ctrl and PNE and methyllycaconitine (a selective α7nAChR antagonist)-treated PNE pups. The effect of IL-1RI blockade (IL-1Ra) on the PCF-mediated apnea was also compared between Ctrl and PNE pups. PNE significantly elevated IL-1β in BALF and upregulated IL1RI gene and protein expression in N/J ganglia and gene in vagal pulmonary C-neurons. All of these responses were eliminated by pretreatment with blockade of α7nAChR. In addition, the prolonged PCF-mediated apnea in PNE pups was significantly shortened by right atrial bolus injection of IL-1Ra. We conclude that PNE enhances pulmonary IL-1β release and PCF IL1RI expression acting via α7nAChR in contributing to sensitization of PCFs and prolongation of the PCF-mediated apneic response. - Highlights: • PNE increased pulmonary IL-1β release and IL1R1 expression in the N/J ganglia. • PNE elevated IL1R1 mRNA in vagal pulmonary C-neurons. • Blockage of peripheral IL1R1 reduced the PNE-induced PCF sensitization. • PNE induced the changes in IL-1β and IL1R1 dependent on action of α7nAChR.

60 APPLIED LIFE SCIENCES↗

Modeling indicates efficient vaccine-based interventions for the elimination of hepatitis C virus among persons who inject drugs in metropolitan Chicago

Background and aims People who inject drugs (PWID) are at highest risk for acquiring and transmitting hepatitis C (HCV) infection. The recent availability of oral direct-acting antiviral (DAA) therapy with reported cure rates >90% can prevent HCV transmission, making HCV elimination an attainable goal among PWID. The World Health Organization (WHO) recently proposed a 90% reduction in HCV incidence as a key objective. Yet, given barriers to the use of DAAs in PWID, including cost, restricted access to DAAs, and risk of reinfection, combination strategies including the availability of effective vaccines are needed to eradicate HCV as a public health threat. This study hopes to model the cost and efficacy of a dual modality approach using HCV vaccines combined with DAAs to reduce HCV incidence by 90% and prevalence by 50% in PWID populations. Methods We developed a mathematical model that represents the HCV epidemic among PWID and calibrated it to empirical data from metropolitan Chicago, Illinois. Four medical interventions were considered: vaccination of HCV naive PWID, DAA treatment, DAA treatment followed by vaccination, and, a combination of vaccination and DAA treatment. Results The combination of vaccination and DAAs is the lowest cost-expensive intervention for achieving the WHO target of 90% incidence reduction. The use of DAAs without a vaccine is much less cost-effective with the additional risk of reinfection after treatment. Vaccination of naïve PWID alone, even when scaled-up to all reachable PWID, cannot achieve 90% reduction of incidence in high-prevalence populations due to infections occurring before vaccination. Similarly, the lowest cost-expensive way to halve prevalence in 15 years is through the combination of vaccination and DAAs. Conclusions The modeling results underscore the importance of developing an effective HCV vaccine and augmenting DAAs with vaccines in HCV intervention strategies in order to achieve efficient reductions in incidence and prevalence.

60 APPLIED LIFE SCIENCES↗

New Perspective on Phase Space Density Analysis for Outer Radiation Belt Enhancements: The Influence of MeV Electron Injections

Observation of growing phase space density (PSD) peak in the outer electron radiation belt has been considered evidence for local wave-driven acceleration as a primary cause of radiation belt enhancement. However, recent studies showed that strong substorm-associated MeV electron injections can also cause significant radiation belt enhancements on fast timescales (~10s min). Such rapid enhancements pose challenges for determining true spatial PSD profiles. To address this, we conduct a detailed spatiotemporal analysis of electron flux and PSD during an enhancement event, using Van Allen Probes data. Our analysis reveals rapid and intermittent flux enhancements. During these rapid enhancements, inbound spacecraft observed false PSD peaks, due to spacecraft's relatively slow movement. However, we identify time intervals of stable fluxes between enhancements, enabling us to determine quasi-stationary PSD profiles with no noticeable peaks. This study provides new insights into accurate PSD analysis, critical for understanding the mechanisms underlying radiation belt enhancements.

79 ASTRONOMY AND ASTROPHYSICS↗

Design, fabrication and test of a pneumatically controlled, renewable, microfluidic bead trapping device for sequential injection analysis applications

This paper describes the design, fabrication, and testing of a pneumatically controlled,renewable, microfluidic device for conducting bead-based assays in an automated sequential injection analysis system. The device used a “brick wall”-like pillar array (pillar size: 20 μm length X 50 μm width X 45 μm height) with 5 μm gaps between the pillars serving as the micro filter. The flow channel where bead trapping occurred is 500 μm wide X 75 μm deep. An elastomeric membrane and an air chamber were located underneath the flow channel. By applying pressure to the air chamber, the membrane is deformed and pushed upward against the filter structure. This effectively traps beads larger than 5 μm and creates a “bed” or micro column of beads that can be perfused and washed with liquid samples and reagents. Upon completion of the assay process, the pressure is released and the beads are flushed out from underneath the filter structure to renew the device. Mouse IgG was used as a model analyte to test the feasibility of using the proposed device for immunoassay applications. Resulting microbeads from an on-chip fluorescent immunoassay were individually examined using flow cytometry. The results show that the fluorescence signal intensity distribution is fairly narrow indicating high chemical reaction uniformity among the beads population. Electrochemical onchip assay was also conducted. A detection limit of 0.1 ng/mL1 ppb was achieved and good device reliability and repeatability were demonstrated. The novel microfluidic-based beadstrapping device thus opens up a new pathway to design micro-bead based biosensor immunoassays for clinical and othervarious applications.

beads trapping↗

Influence of injection beam emittance on beam transmission efficiency in a cyclotron

The JAEA AVF cyclotron accelerates various kinds of high-energy ion beams for research in biotechnology and materials science. Beam intensities of an ion species of the order of 10{sup −9}–10{sup −6} ampere are often required for various experiments performed sequentially over a day. To provide ion beams with sufficient intensity and stability, an operator has to retune an ion source in a short time. However, the beam intensity downstream of the cyclotron rarely increases in proportion to the intensity at the ion source. To understand the cause of this beam behavior, transmission efficiencies of a {sup 12}C{sup 5+} beam from an electron cyclotron resonance ion source to the cyclotron were measured for various conditions of the ion source. Moreover, a feasible region for acceleration in the emittance of the injection beam was clarified using a transverse-acceptance measuring system. We confirmed that the beam emittance and profile were changed depending on the condition of the ion source and that matching between the beam emittance and the acceptance of the cyclotron was degraded. However, after fine-tuning to improve the matching, beam intensity downstream of the cyclotron increased.

43 PARTICLE ACCELERATORS↗

Operating characteristics of a new ion source for KSTAR neutral beam injection system

A new positive ion source for the Korea Superconducting Tokamak Advanced Research neutral beam injection (KSTAR NBI-1) system was designed, fabricated, and assembled in 2011. The characteristics of the arc discharge and beam extraction were investigated using hydrogen and helium gas to find the optimum operating parameters of the arc power, filament voltage, gas pressure, extracting voltage, accelerating voltage, and decelerating voltage at the neutral beam test stand at the Korea Atomic Energy Research Institute in 2012. Based on the optimum operating condition, the new ion source was then conditioned, and performance tests were primarily finished. The accelerator system with enlarged apertures can extract a maximum 65 A ion beam with a beam energy of 100 keV. The arc efficiency and optimum beam perveance, at which the beam divergence is at a minimum, are estimated to be 1.0 A/kW and 2.5 uP, respectively. The beam extraction tests show that the design goal of delivering a 2 MW deuterium neutral beam into the KSTAR Tokamak plasma is achievable.

43 PARTICLE ACCELERATORS↗

Development of a radio frequency ion source with multi-helicon plasma injectors for neutral beam injection system of Versatile Experiment Spherical Torus

Despite of high plasma density, helicon plasma has not yet been applied to a large area ion source such as a driver for neutral beam injection (NBI) system due to intrinsically poor plasma uniformity in the discharge region. In this study, a radio-frequency (RF) ion source with multi-helicon plasma injectors for high plasma density with good uniformity has been designed and constructed for the NBI system of Versatile Experiment Spherical Torus at Seoul National University. The ion source consists of a rectangular plasma expansion chamber (120 × 120 × 120 mm{sup 3}), four helicon plasma injectors with annular permanent magnets and RF power system. Main feature of the source is downstream plasma confinement in the cusp magnetic field configuration which is generated by arranging polarities of permanent magnets in the helicon plasma injectors. In this paper, detailed design of the multi-helicon plasma injector and plasma characteristics of the ion source are presented.

43 PARTICLE ACCELERATORS↗

Angular-divergence calculation for Experimental Advanced Superconducting Tokamak neutral beam injection ion source based on spectroscopic measurements

Calorimetric method has been primarily applied for several experimental campaigns to determine the angular divergence of high-current ion source for the neutral beam injection system on the Experimental Advanced Superconducting Tokamak (EAST). A Doppler shift spectroscopy has been developed to provide the secondary measurement of the angular divergence to improve the divergence measurement accuracy and for real-time and non-perturbing measurement. The modified calculation model based on the W7AS neutral beam injectors is adopted to accommodate the slot-type accelerating grids used in the EAST's ion source. Preliminary spectroscopic experimental results are presented comparable to the calorimetrically determined value of theoretical calculation.

43 PARTICLE ACCELERATORS↗

Evaluating the integrity of the reinforced concrete structure repaired by epoxy injection using simulated transfer function of impact-echo response

Cracks and honeycombs are often found inside reinforced concrete (RC) structure caused by excessive external force, or improper casting of concrete. The repairing method usually involves epoxy injection. The impact-echo method, which is a sensitive for detecting of the interior voids, may not be applicable to assess the integrity of the repaired member as both air and epoxy are less in acoustic impedances. In this study, the repaired RC structure was evaluated by the simulated transfer function of the IE displacement waveform where the R-wave displacement waveform is used as a base of a simulated force-time function. The effect of different thickness of the epoxy layer to the amplitude corresponding to the interface is studied by testing on specimen containing repaired naturally delaminated cracks with crack widths about 1 mm, 3 mm and 5 mm. The impact-echo responses were compared with the drilling cores at the test positions. The results showed the cracks were not fully filled with epoxy when the peak amplitude corresponding to the interface dropped less than 20%. The peak corresponding to the thicker epoxy layer tends to be larger in amplitude. A field study was also performed on a column damaged by earthquake before and after repairing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrasound based monitoring of the injection moulding process - Methods, applications and limitations

We developed novel non-invasive ultrasound based systems for the measurement of temperature distributions in the screw-ante chamber, the detection of unmelted granules and for the monitoring of the plasticizing process along the screw channel. The temperature of the polymer melt stored in the screw ante-chamber after the plasticization should be homogeneous. However, in reality the polymer melt in the screw ante-chamber is not homogeneous. Due to the fact the sound velocity in a polymer melt is temperature depending, we developed a tomography system using the measured transit times of ultrasonic pulses along different sound paths for calculating the temperature distribution in radial direction of a polymer melt in the screw ante-chamber of an injection moulding machine. For the detection of unmelted granules in the polymer melt we implemented an ultrasound transmission measurement. By analyzing the attenuation of the received pulses it is possible to detect unwanted inclusions. For the monitoring of the plasticizing process in the channels of the screw an ultrasonic pulse is transmitted into the barrel. By analyzing the reflected pulses it is possible to estimate solid bed and melt regions in the screw channel. The proposed systems were tested for accuracy and validity by simulations and test measurements.

42 ENGINEERING↗

Pressure-assisted fabrication of organic light emitting diodes with MoO{sub 3} hole-injection layer materials

In this study, pressures of ∼5 to ∼8 MPa were applied to organic light emitting diodes containing either evaporated molybdenum trioxide (MoO{sub 3}) or spin-coated poly(3,4-ethylene dioxythiophene) doped with poly(styrene sulphonate) (PEDOT:PSS) hole-injection layers (HILs). The threshold voltages for both devices were reduced by about half, after the application of pressure. Furthermore, in an effort to understand the effects of pressure treatment, finite element simulations were used to study the evolution of surface contact between the HIL and emissive layer (EML) under pressure. The blister area due to interfacial impurities was also calculated. This was shown to reduce by about half, when the applied pressures were between ∼5 and 8 MPa. The finite element simulations used Young's modulus measurements of MoO{sub 3} that were measured using the nanoindentation technique. They also incorporated measurements of the adhesion energy between the HIL and EML (measured by force microscopy during atomic force microscopy). Within a fracture mechanics framework, the implications of the results are then discussed for the pressure-assisted fabrication of robust organic electronic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effects of spin doping and spin injection in the luminescence and vibrational spectrum of C{sub 60}

We have studied the Raman spectrum and photoemission of hybrid magneto-fullerene devices. For C{sub 60} layers on cobalt, the spin polarized electron transfer shifts the photoemission energy, reducing the zero phonon contribution. The total luminescence of hybrid devices can be controlled via spin injection from magnetic electrodes, with changes of the order of 10%–20% at room temperature. Spin polarised currents alter as well the Raman spectrum of the molecules, enhancing some modes by a factor 5 while shifting others by several wavenumbers due to a spin-dependent hopping time and/or enhanced intermolecular interactions. These results can be used to measure spin polarisation in molecules or to fabricate magneto-optic and magneto-vibrational devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of axial injection displacement with trim coil current unbalance

The Dee probe used for measuring internal radial beam intensity shows large losses inside the radius of 20 cm of the 88 in. cyclotron. The current of the top and bottom innermost trim coil 1 is unbalanced to study effects of the axial injection displacement. A beam profile monitor images the ion beam bunches, turn by turn. The experimental bunch center of mass position is compared with calculations of the magnetic mirror effect displacement and shows good agreement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The dependence of potential well formation on the magnetic field strength and electron injection current in a polywell device

A capacitive probe has been used to measure the plasma potential in a polywell device in order to observe the dependence of potential well formation on magnetic field strength, electron injection current, and polywell voltage bias. The effectiveness of the capacitive probe in a high energy electron plasma was determined by measuring the plasma potential of a planar diode with an axial magnetic field. The capacitive probe was translated along the axis of one of the field coils of the polywell, and the spatial profile of the potential well was measured. The confinement time of electrons in the polywell was estimated with a simple analytical model which used the experimentally observed potential well depths, as well as a simulation of the electron trajectories using particle orbit theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Narrow-band injection seeding of a terahertz frequency quantum cascade laser: Selection and suppression of longitudinal modes

A periodically poled lithium niobate (PPLN) crystal with multiple poling periods is used to generate tunable narrow-bandwidth THz pulses for injection seeding a quantum cascade laser (QCL). We demonstrate that longitudinal modes of the quantum cascade laser close to the gain maximum can be selected or suppressed according to the seed spectrum. The QCL emission spectra obtained by electro-optic sampling from the quantum cascade laser, in the most favorable case, shows high selectivity and amplification of the longitudinal modes that overlap the frequency of the narrow-band seed. Proper selection of the narrow-band THz seed from the PPLN crystal discretely tunes the longitudinal mode emission of the quantum cascade laser. Moreover, the THz wave build-up within the laser cavity is studied as a function of the round-trip time. When the seed frequency is outside the maximum of the gain spectrum the laser emission shifts to the preferential longitudinal mode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simultaneous generation of quasi-monoenergetic electron and betatron X-rays from nitrogen gas via ionization injection

Upon the interaction of 60 TW Ti: sapphire laser pulses with 4 mm long supersonic nitrogen gas jet, a directional x-ray emission was generated along with the generation of stable quasi-monoenergetic electron beams having a peak energy of 130 MeV and a relative energy spread of ∼ 20%. The betatron x-ray emission had a small divergence of 7.5 mrad and a critical energy of 4 keV. The laser wakefield acceleration process was stimulated in a background plasma density of merely 5.4 × 10{sup 17 }cm{sup −3} utilizing ionization injection. The non-self-focusing and stable propagation of the laser pulse in the pure nitrogen gaseous plasma should be responsible for the simultaneous generation of the high-quality X-ray and electron beams. Those ultra-short and naturally-synchronized beams could be applicable to ultrafast pump-probe experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗