Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Germanium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Background investigation in EDELWEISS-III

Protection from and rejection of backgrounds is a key issue for the EDELWEISS-III direct dark matter detection experiment which aims at exploring the 10{sup −9} pb cross-section region for spin-independent WIMP-nucleon interaction. The detector is located in the low radioactivity environment of the Modane Underground Laboratory and consists of 36 advanced FID germanium detectors operating at 18 mK in a dilution refrigerator in order to identify eventual rare nuclear recoils induced by elastic scattering of WIMPs from our Galactic halo. I will discuss the background and the methods of rejecting it with the FID detectors. Detector performances and the first analysis of data acquired in a long-term campaign will be presented as well. The FID detector technology is not limited to EDELWEISS-III but can further be employed in the next generation of cryogenic detector experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent to incoherent cross section ratio for 59.54 keV gamma rays at scattering angle of 110°

The coherent (Rayleigh) to incoherent (Compton) scattering cross-section ratio of elements, in the range 13 ≤ Z ≤ 82, are determined experimentally for 59.54 keV incident gamma photons. An HPGe (High purity germanium) semiconductor detector is employed, at scattering angle of 110°, to record the spectra originating from interactions of incident gamma photons with the target under investigation. The intensity ratio of Rayleigh to Compton scattered peaks observed in the recorded spectra, and corrected for photo-peak efficiency of gamma detector and absorption of photons in the target and air, along with the other required parameters provides the differential cross-section ratio. The measured values of cross-section ratio are found to agree with theoretical predictions based upon non-relativistic form factor, relativistic form factor, modified form factor and S-matrix theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hydrogen concentration and electric field dependent on electronic properties of germanene

Electronic properties of the pristine/hydrogenated germanene are investigated by means of first principles calculations. Our calculation shows interesting results where the electronic properties of the hydrogenated germanene exhibit semiconductor with a direct band gap. It is interesting because pristine germanene (germanium analogue to graphene) has semi-metal properties with zero band gap. We also obtained that the band gap of hydrogenated germanene was influenced by the hydrogen (H) concentration, it is decreasing non-linearly as the H concentration decreased. As 100 percent concentration of H applied on top and bottom layer of germanene, the band gap is 1.41 eV. The pairing of the p{sub z}-orbital of Ge with the s-orbital of H gave contribution to the band gap of hydrogenated germanene. External electrical field is also can be applied to open the band gap. The band gap increasing linearly when the external electrical field increased on pristine germanene. The external electrical field no longer effect the band gap when it applied to the hydrogenated germanene.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimizing photon-pair generation electronically using a p-i-n diode incorporated in a silicon microring resonator

Silicon photonic microchips may be useful for compact, inexpensive, room-temperature optically pumped photon-pair sources, which unlike conventional photon-pair generators based on crystals or optical fibers, can be manufactured using CMOS-compatible processes on silicon wafers. It has been shown that photon pairs can be created in simple structures such as microring resonators at a rate of a few hundred kilohertz using less than a milliwatt of optical pump power, based on the process of spontaneous four-wave mixing. To create a practical photon-pair source, however, also requires some way of monitoring the device and aligning the pump wavelength when the temperature varies, since silicon resonators are highly sensitive to temperature. In fact, monitoring photodiodes are standard components in classical laser diodes, but the incorporation of germanium or InGaAs photodiodes would raise the cost and fabrication complexity. Here, we present a simple and effective all-electronic technique for finding the optimum operating point for the microring used to generate photon pairs, based on measuring the reverse-biased current in a silicon p-i-n junction diode fabricated across the waveguide that constitutes the silicon microring. We show that by monitoring the current, and using it to tune the pump laser wavelength, the photon-pair generation properties of the microring can be preserved over a temperature range of more than 30 °C.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray pinhole camera setups used in the Atomki ECR Laboratory for plasma diagnostics

Imaging of the electron cyclotron resonance (ECR) plasmas by using CCD camera in combination with a pinhole is a non-destructive diagnostics method to record the strongly inhomogeneous spatial density distribution of the X-ray emitted by the plasma and by the chamber walls. This method can provide information on the location of the collisions between warm electrons and multiple charged ions/atoms, opening the possibility to investigate the direct effect of the ion source tuning parameters to the plasma structure. The first successful experiment with a pinhole X-ray camera was carried out in the Atomki ECR Laboratory more than 10 years ago. The goal of that experiment was to make the first ECR X-ray photos and to carry out simple studies on the effect of some setting parameters (magnetic field, extraction, disc voltage, gas mixing, etc.). Recently, intensive efforts were taken to investigate now the effect of different RF resonant modes to the plasma structure. Comparing to the 2002 experiment, this campaign used wider instrumental stock: CCD camera with a lead pinhole was placed at the injection side allowing X-ray imaging and beam extraction simultaneously. Additionally, Silicon Drift Detector (SDD) and High Purity Germanium (HPGe) detectors were installed to characterize the volumetric X-ray emission rate caused by the warm and hot electron domains. In this paper, detailed comparison study on the two X-ray camera and detector setups and also on the technical and scientific goals of the experiments is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for double beta processes in {sup 106}Cd with enriched {sup 106}CdWO{sub 4} crystal scintillator in coincidence with four crystals HPGe detector

A radiopure cadmium tungstate crystal scintillator, enriched in {sup 106}Cd ({sup 106}CdWO{sub 4}), was used to search for double beta decay processes in {sup 106}Cd in coincidence with an ultra-low background set-up containing four high purity germanium (HPGe) detectors in a single cryostat. The experiment has been completed after 13085 h of data taking. New improved limits on most of the double beta processes in {sup 106}Cd have been set on the level of 10{sup 20}−10{sup 21} yr. Tn particular, the half-life limit on the two neutrino electron capture with positron emission, T{sub 1/2} ≥ 1.8 × 10{sup 21} yr, reached the region of theoretical predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High density plasmas and new diagnostics: An overview (invited)

One of the limiting factors for the full understanding of Electron Cyclotron Resonance Ion Sources (ECRISs) fundamental mechanisms consists of few types of diagnostic tools so far available for such compact machines. Microwave-to-plasma coupling optimisation, new methods of density overboost provided by plasma wave generation, and magnetostatic field tailoring for generating a proper electron energy distribution function, suitable for optimal ion beams formation, require diagnostic tools spanning across the entire electromagnetic spectrum from microwave interferometry to X-ray spectroscopy; these methods are going to be implemented including high resolution and spatially resolved X-ray spectroscopy made by quasi-optical methods (pin-hole cameras). The ion confinement optimisation also requires a complete control of cold electrons displacement, which can be performed by optical emission spectroscopy. Several diagnostic tools have been recently developed at INFN-LNS, including “volume-integrated” X-ray spectroscopy in low energy domain (2-30 keV, by using silicon drift detectors) or high energy regime (>30 keV, by using high purity germanium detectors). For the direct detection of the spatially resolved spectral distribution of X-rays produced by the electronic motion, a “pin-hole camera” has been developed also taking profit from previous experiences in the ECRIS field. The paper will give an overview of INFN-LNS strategy in terms of new microwave-to-plasma coupling schemes and advanced diagnostics supporting the design of new ion sources and for optimizing the performances of the existing ones, with the goal of a microwave-absorption oriented design of future machines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron cyclotron resonance ion source plasma characterization by X-ray spectroscopy and X-ray imaging

An experimental campaign aiming to investigate electron cyclotron resonance (ECR) plasma X-ray emission has been recently carried out at the ECRISs—Electron Cyclotron Resonance Ion Sources laboratory of Atomki based on a collaboration between the Debrecen and Catania ECR teams. In a first series, the X-ray spectroscopy was performed through silicon drift detectors and high purity germanium detectors, characterizing the volumetric plasma emission. The on-purpose developed collimation system was suitable for direct plasma density evaluation, performed “on-line” during beam extraction and charge state distribution characterization. A campaign for correlating the plasma density and temperature with the output charge states and the beam intensity for different pumping wave frequencies, different magnetic field profiles, and single-gas/gas-mixing configurations was carried out. The results reveal a surprisingly very good agreement between warm-electron density fluctuations, output beam currents, and the calculated electromagnetic modal density of the plasma chamber. A charge-coupled device camera coupled to a small pin-hole allowing X-ray imaging was installed and numerous X-ray photos were taken in order to study the peculiarities of the ECRIS plasma structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of uranium bearing material using x-ray fluorescence and direct gamma-rays measurement techniques

Uranium ore can be easily detected due to various gamma-ray energies emitted from uranium daughters particularly from {sup 238}U daughters such as {sup 214}Bi, {sup 214}Pb and {sup 226}Ra. After uranium is extracted from uranium ore, only low energy gamma-rays emitted from {sup 235}U may be detected if the detector is placed in close contact to the specimen. In this research, identification and characterization of uranium bearing materials is experimentally investigated using direct measurement of gamma-rays from {sup 235}U in combination with the x-ray fluorescence (XRF) technique. Measurement of gamma-rays can be conducted by using high purity germanium (HPGe) detector or cadmium telluride (CdTe) detector while a {sup 57}Coradioisotope-excited XRF spectrometer using CdTe detector is used for elemental analysis. The proposed technique was tested with various uranium bearing specimens containing natural, depleted and enriched uranium in both metallic and powder forms.

07 ISOTOPE AND RADIATION SOURCES↗

Characterisation of imperial college reactor centre legacy waste using gamma-ray spectrometry

Waste characterisation is a principal component in waste management strategy. The characterisation includes identification of chemical, physical and radiochemical parameters of radioactive waste. Failure to determine specific waste properties may result in sentencing waste packages which are not compliant with the regulation of long term storage or disposal. This project involved measurement of intensity and energy of gamma photons which may be emitted by radioactive waste generated during decommissioning of Imperial College Reactor Centre (ICRC). The measurement will use High Purity Germanium (HPGe) as Gamma-ray detector and ISOTOPIC-32 V4.1 as analyser. In order to ensure the measurements provide reliable results, two quality control (QC) measurements using difference matrices have been conducted. The results from QC measurements were used to determine the accuracy of the ISOTOPIC software.

07 ISOTOPE AND RADIATION SOURCES↗

Basal-plane thermal conductivity of nanocrystalline and amorphized thin germanane

Recently, we synthesized Germanane (GeH), a hydrogen-terminated layered germanium structure. We employed a four-probe thermal transport measurement method to obtain the basal-plane thermal conductivity of thin exfoliated GeH flakes and correlated the measurement results with the crystal structure. Furthermore, the obtained thermal conductivity increases with increasing temperature, suggesting that extrinsic grain boundary and defect scattering dominate intrinsic phonon-phonon scattering. Annealing a polycrystalline GeH sample at 195 C caused it to become amorphous, reducing the room-temperature thermal conductivity from 0.53± 0.03 W m -1 K -1 , which is close to the value calculated for 3.3 nm grain size, to 0.29± 0.02 W m -1 K -1 , which approaches the calculated amorphous limit in the basal plane thermal conductivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal diffusivity determination using heterodyne phase insensitive transient grating spectroscopy

The elastic and thermal transport properties of opaque materials may be measured using transient grating spectroscopy (TGS) by inducing and monitoring periodic excitations in both reflectivity and surface displacement. The “phase grating” response encodes both properties of interest, but complicates quantitative analysis by convolving temperature dynamics with surface displacement dynamics. Hence, thermal transport characteristics are normally determined using the “amplitude grating” response to isolate the surface temperature dynamics. Yet, this signal character requires absolute heterodyne phase calibration and contains no elastic property information. Here, a method is developed by which phase grating TGS measurements may be consistently analyzed to determine thermal diffusivity with no prior knowledge of the expected properties. To demonstrate this ability, the wavelength-dependent 1D effective thermal diffusivity of pure germanium is measured using this type of response and found to be consistent with theoretical predictions made by solving the Boltzmann transport equation. This ability to determine the elastic and thermal properties from a single set of TGS measurements will be particularly advantageous for new in situ implementations of the technique being used to study dynamic materials systems.

36 MATERIALS SCIENCE↗

Frequency-selective excitation of high-wavevector phonons

We demonstrate here the selective excitation of a narrow frequency band of TA phonons throughout the Brillouin zone of germanium using a sinusoidally modulated picosecond laser pulse. The pulse is produced through the combination of two chirped and delayed pulses using a stabilized interferometer. The phonon excitations are probed by time- and momentum- resolved x-ray diffuse scattering.

36 MATERIALS SCIENCE↗

Increasing the signal-to-noise ratio of magnetic tunnel junctions by cryogenic preamplification

Cryogenic preamplification using silicon–germanium heterojunction bipolar transistors has proven to be effective in increasing the signal-to-noise ratio of the tunnel magnetoresistance of high resistance magnetic tunnel junctions at 8 K. The magnetic tunnel junctions used have resistances greater than 1 MΩ, and the cryogenic measurement system still has sufficient bandwidth for the 1/f noise to roll off. A noise model for the system has been proposed and evaluated experimentally. The noise temperature and minimum noise temperature of the transistor used in the experiment are calculated and compared. The signal-to-noise ratio of the junction alone and the transistor-junction system is derived from the sample and circuit parameters and compared. Experimental data show a signal-to-noise ratio increase by a factor of 6.62 after adding in the cryogenic preamplifier. Additionally, an increase in 1/f noise in the antiparallel state of the tunneling junction as opposed to the parallel state is observed giving evidence of 1/f noise dependence on the magnetic state of the junction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rutile GeO 2 : An ultrawide-band-gap semiconductor with ambipolar doping

Ultra-wide-band-gap (UWBG) semiconductors have tremendous potential to advance electronic devices as device performance improves superlinearly with the increasing gap. Ambipolar doping, however, has been a major challenge for UWBG materials as dopant ionization energy and charge compensation generally increase with the increasing bandgap and significantly limit the semiconductor devices that can currently be realized. Using hybrid density functional theory, we demonstrate rutile germanium oxide (r-GeO 2 ) to be an alternative UWBG (4.68 eV) material that can be ambipolarly doped. We identify Sb Ge , As Ge , and F O as possible donors with low ionization energies and propose growth conditions to avoid charge compensation by deep acceptors such as V Ge and N O . On the other hand, acceptors such as Al Ge have relatively large ionization energies (0.45 eV) due to the formation of localized hole polarons and are likely to be passivated by V O , Ge i , and self-interstitials. Furthermore, we find that the co-incorporation of Al Ge with interstitial H can increase the solubility limit of Al and enable hole conduction in the impurity band. Our results show that r-GeO 2 is a promising UWBG semiconductor that can overcome current doping challenges and enable the next generation of power electronics devices.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pushered single shell implosions for mix and radiation trapping studies using high-Z layers on National Ignition Facility

Pushered Single Shells (PSSs) are another approach to Inertial Confinement Fusion implosions that employ high-Z materials in the innermost capsule layer (pusher) as a means to enhance radiation trapping and lower core ignition requirements. However, adding high-Z materials can also increase losses due to mix, provide extra tamping, and make the capsule emission opaque to x-ray diagnostics. The first PSS implosions performed on the National Ignition Facility use plastic ablators with a germanium (Ge) dopant as a high-Z surrogate in the pusher to isolate the effects of high-Z mix and radiation trapping without changing tamping. Using a 2-shock laser pulse, the PSS implosions are designed and symmetrized to reach 3.7 keV core temperatures. A low concentration (2.8%) Ge dopant is added to the innermost layer, and the resulting effects on mix and x-ray opacity are observed. The method of separated reactants is used to infer information about mixing between the deuterated plastic pusher and the capsule fill gas (25% tritium) from the resulting nuclear DT reactions. Radiation transport is studied via capsule emission x-ray spectroscopy and imaging. Both nuclear and x-ray data corroborate the hypothesis that the addition of Ge strongly affects the mix region through radiation losses but has a minimal effect on the core and the warm, unmixed regions. Simulations using diffusive and turbulent mix models agree qualitatively with data, but quantitative agreement may require hybrid mix models that can model the transitional regime between turbulence and diffusion. Simulations matching the observables show increased core radiation trapping when Ge is added.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimized x-ray sources for x-ray diffraction measurements at the Omega Laser Facility

The use of x-ray diffraction (XRD) measurements in laser-driven dynamic compression experiments at high-power laser facilities is becoming increasingly common. Diffraction allows one to probe in situ the transformations occurring at the atomic level at extreme conditions of pressure, temperature, and time scale. In these measurements, the x-ray source is generated by irradiation of a solid foil. Under certain laser drive conditions, quasimonochromatic He-α radiation is generated. Careful analysis of the x-ray source plasma spectra reveals that this radiation is not a single line emission and that monochromaticity is highly dependent on the laser irradiance. In this work, we analyze how the spectra emitted by laser-irradiated copper, germanium, and iron foils at the Omega Laser vary depending on different laser drive conditions and discuss the implications for XRD experiments.

47 OTHER INSTRUMENTATION↗

Cubic crystals in an x-ray polarization-splitting geometry

Hexagonal and cubic crystals contain paired sets of internal planes that reflect the linearly polarized components of certain x rays into two separate, perpendicular directions. For the cubic crystals, two distinct crystal orientations provide the same polarization-splitting geometry. One of the orientations may have advantages for plasma spectroscopy by suppressing unwanted reflections. This paper demonstrates the two orientations with a germanium crystal and K characteristic lines from copper and zirconium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗