Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gas Separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Study of outgassing and decomposition of space shuttle heat protection tiles, fillers and adhesive

The purpose of this project was to determine the chemicals desorbing from the space shuttle heat protection tiles. The original protocol for this project involved direct insertion probe mass spectrometry (DIPMS) analysis of the outgassing products from the tiles. However, this method proved unsatisfactory due to the large number of compounds desorbing from the tiles. A purge and trap technique was then employed to collect and separate the chemicals desorbing from the tiles. The maximum temperature in this analysis was 180 C which is the gas chromatograph fused silica capillary column's temperature limit. The desorption was also carried out at atmospheric pressure with helium as the purge gas. A description of the modified protocol is given. All compounds are tentatively identified.

Proctor, B. L.↗

A model of Comet P/Giacobini-Zinner

A computer model of Comet P/Giacobini-Zinner is presented which contains photoprocesses, gas-phase chemical kinetics, energy balance, multifluid hydrodynamics with a transition to free molecular flow, and solar wind interaction. Recently the physics for electrons in the model has been improved by including electron impact ionization and dissociation and separately accounting for electron energetics. Electron heating and cooling mechanisms include photoprocesses, recombination processes, inelastic and elastic collisions with heavy molecules, and expansion cooling. The model incorporates an internally consistent interaction of the solar wind with the coma gas using the axisymmetric ideal fluid dynamic equations. The nuclear size and composition have been chosen to make the calculations relevant to the September 11, 1985 International Cometary Explorer (ICE) encounter with Comet P/Giacobini-Zinner. Model profiles of the temperature, velocity, and number density of the electrons are in good agreement with measurements along ICE's trajectory. The results indicate the probe passed through a region of the coma at the onset of the plasma tail.

Boice, D. C.↗

Ram-pressure stripping of the multiphase interstellar medium of the Virgo cluster elliptical galaxy M86 (NGC 4406)

The available infrared, optical, and X-ray data on the elliptical galaxy M86, which is experiencing strong ram-pressure stripping in the intracluster medium of the Virgo Cluster, are analyzed. A significant component of infrared 60 micron emission displaced from the center of the galaxy is found. The displaced 60 micron emission lies on the optical major axis of the galaxy in the direction of perturbations to the optical isophotes and is coincident with a small feature in X-ray emission southwest of the X-ray plume. The displaced infrared emission is interpreted in terms of collisionally heated dust exposed to hot gas where ram pressure and turbulence are disrupting the stripped interstellar medium of the galaxy. The displacement of the outer optical isophotes in the direction of the stripped gas in suggested to be due to reflection of star-light on the dust grains. Ram pressure has separated and exposed the various components of the multiphase interstellar medium of M86, enabling these constituents to be identified and analyzed separately for the first time in an elliptical galaxy.

White, David A.↗

Control of on-orbit contamination for the Argos (P91-1) satellite

The ARGOS (P91-1) satellite presents a challenging combination of on-orbit contamination concerns while mandating a low-cost approach. Several experiment payloads contain contamination sensitive optics, another contains large quantities of CO2 and Xe for release in orbit, and one contains an NH3 fueled arc jet thruster. The latter includes a suite of sensors to measure contamination; so prelaunch calculations will be tested. Planned contamination control techniques include: physical separation of sensitive surfaces from contamination sources; flight covers to protect sensitive surfaces during early outgassing on-orbit; gas release and thruster operation early in the flight, before flight covers are opened; and careful control of plumes and venting through a detailed analysis of each.

Kelley, Joseph G.↗

Hot hydrogen testing of metallic turbo pump materials

The objectives of this investigation are to expose heat resistant alloys to hydrogen at elevated temperatures and to use various microstructural and analytical techniques to determine the chemical and rate process involved in degradation of these materials due to hydrogen environment. Inconel 718 and NASA-23 (wrought and cast) are candidate materials. The degradation of these materials in the presence of 1 to 5 atmospheric pressure of hydrogen from 450 C to 1100 C was examined. The hydrogen facility at Auburn University was used for this purpose. Control experiments were also conducted wherein the samples were exposed to vacuum so that a direct comparison of the results would separate the thermal contribution from the hydrogen effects. The samples were analyzed prior to and after exposure. A residual gas collection system was used to determine the gaseous species produced by any chemical reaction that may have occurred during the exposure. Analysis of this gas sample shows only the presence of H2 as expected. Analyses of the samples were conducted using optical microscopy, x-ray diffraction, scanning electron microscopy, and weight change. There appears to be no change in weight of the samples as a result of hydrogen exposure. In addition no visible change on the surface structure was detected. This indicates that the materials of interest do not have strong interaction with hot hydrogen. This is consistent with the microstructure results.

Zee, Ralph↗

Paschen Considerations for High Altitude Airships

Recently, there have been several proposals submitted to funding agencies for long-lived high altitude (about 70,000 feet) airships for communications, surveillance, etc. In order for these airships to remain at altitude, high power, high efficiency, lightweight solar arrays must be used, and high efficiency power management and distribution systems must be employed. The needs for high power and high efficiency imply high voltage systems. However, the air pressure at these extreme altitudes is such that electrical power systems will be near the Paschen discharge minimum over a wide range of electrode separations. In this paper, preliminary calculations are made for acceptable high voltage design practices under ambient, hydrogen and helium gas atmospheres.

Ferguson, D. C.↗

Herschel Extreme Lensing Line Observations: Dynamics of Two Strongly Lensed Star-Forming Galaxies near Redshift z=2*

We report on two regularly rotating galaxies at redshift z approx. = 2, using high-resolution spectra of the bright [C microns] 158 micrometers emission line from the HIFI instrument on the Herschel Space Observatory. Both SDSS090122.37+181432.3 ("S0901") and SDSSJ120602.09+514229.5 ("the Clone") are strongly lensed and show the double-horned line profile that is typical of rotating gas disks. Using a parametric disk model to fit the emission line profiles, we find that S0901 has a rotation speed of v sin(i) approx. = 120 +/- 7 kms(sup −1) and a gas velocity dispersion of (standard deviation)g < 23 km s(sup −1) (1(standard deviation)). The best-fitting model for the Clone is a rotationally supported disk having v sin(i) approx. = 79 +/- 11 km s(sup −1) and (standard deviation)g 4 kms(sup −1) (1(standard deviation)). However, the Clone is also consistent with a family of dispersion-dominated models having (standard deviation)g = 92 +/- 20 km s(sup −1). Our results showcase the potential of the [C microns] line as a kinematic probe of high-redshift galaxy dynamics: [C microns] is bright, accessible to heterodyne receivers with exquisite velocity resolution, and traces dense star-forming interstellar gas. Future [C microns] line observations with ALMA would offer the further advantage of spatial resolution, allowing a clearer separation between rotation and velocity dispersion.

LENSING↗

Tracking the Hunga Tonga-Hunga Ha’apai Eruption Stratospheric Aerosol and Trace Gas Plumes Using Machine Learning

The Hunga Tonga-Hunga Ha’apai (HTHH) submarine volcano had an explosive eruption phase on January 15, 2022, that thrusted ash, gases, and water vapor through the troposphere and into the stratosphere. The stratospheric volcanic plume included aerosol precursor gases such as SO2 and H2S as well as anomalously high water vapor concentrations due to the submarine oceanic origin. With these atmospheric constituents, the sulfuric gases and water vapor formed sulfate (SO4) particles via gas-to-particle reactions and these aerosols likely increased in size due to hygroscopic growth within anomalously humid regions. Strong easterlies and gravity waves propagated the volcanic impacts throughout the stratosphere. Orbital and suborbital passive sensor retrievals detected changes in the aerosol and trace gas characteristics within the atmospheric column for cloud-free regions over the southern hemisphere. While the CALIPSO lidar can detect aerosol layers in the stratosphere, passive sensors such as MODIS retrieved the total column aerosol abundance and characteristics. Previous studies used manual tracking methods to determine volcanic plume positions and compared them to ground observations. In this study, we examine the machine learning (ML) approaches including segmentation, object detection, and object tracking to identify and track aerosol and trace gas plumes using orbital and suborbital sensor data. This ML implementation strives to provide a more systematic approach to separate total column effects from those of the stratosphere. Similar ML tracking may be useful for stratospheric impact events observed historically by CALIPSO and in the future with EarthCare and the Atmosphere Observing System (AOS) lidar-capable missions.

Rhys Leahy↗

Resistance heater rod and method of making such

A resistive heater capable of delivering heat loads on the same order as those produced by in-pile nuclear fuel experiments. The heater rod provides the energy for high-temperature steady-state testing, as well as the power needed to simulate the transient pulse in the Transient Reactor Test Loop (TRTL) system. The resistive heater includes a removable housing, two or more thermal conductors in the housing; and one or more stabilizers coupled to the two or more thermal conductors to keep the two or more thermal conductors separated to avoid shorting, wherein the two or more thermal conductors are coupled to the housing via an inert gas (e.g., Helium). The two or more thermal conductors comprise a material with substantially zero infrared spectrum (e.g., sapphire, silica, or glass).

LaBrier, Daniel↗

Computer-aided process intensification of natural gas to methanol process

The recent revolution in shale gas has presented opportunities for distributed manufacturing of key commodity chemicals, such as methanol, from methane. However, the conventional methane-to-methanol process is energy intensive which negatively affects the profitability and sustainability. Here an intensified process configuration that is both economically attractive and environmentally sustainable. This flowsheet is systematically discovered using the building block-based representation and optimization methodology. The new process configuration utilizes membrane-assisted reactive separations and can have as much as 190% higher total annual profit compared to a conventional configuration. Additionally, it has 57% less CO 2 -equivalent greenhouse gas emission. Such drastic improvement highlights the advantages of building block-based computer-aided process intensification method.

42 ENGINEERING↗

Structure of nonevaporating sprays. I - Initial conditions and mean properties

Structure measurements were completed within the dilute portion of axisymmetric nonevaporating sprays. Measurements included: mean velocities, velocity fluctuations, and Reynolds stress of the gas phase; and mean velocities, fluctuating velocities, mass flux, and diameter distributions of the drop phase. The measurements were used to evaluate three typical methods of analyzing sprays: (1) a locally homogeneous flow (LHF) analysis, where slip between the phases is neglected; (2) a deterministic separated flow (DSF) analysis, where slip is considered but effects of drop interactions with turbulence are ignored; and (3) a stochastic separated flow (SSF) analysis, where effects of both slip and turbulence are considered using random-walk computations for drop motion. Measurements of initial conditions of both phases near the injector, mean gas-phase properties, and liquid flux distributions are described herein. Best agreement between predictions and measurements was obtained with the SSF model, which provided a reasonable representation of turbulent dispersion of drops. A companion paper presents additional measurements of drop continuous phase properties.

Solomon, A. S. P.↗

Computational Aeroheating Predictions for Mars Lander Configurations

The proposed Mars Science Laboratory (MSL) mission is intended to deliver a large rover to the Martian surface within 10 km of the target site. This paper presents computational fluid dynamics (CFD) predictions of forebody heating rates for two MSL entry configurations with fixed aerodynamic trim tabs. Results are compared to heating on a 70-deg sphere-cone reference geometry. All three heatshield geometries are designed to trim hypersonically at a 16 deg angle of attack in order to generate the lift-to-drag ratio (LID) required for precision landing. Comparisons between CFD and tunnel data are generally in good agreement for each configuration, but the computations predict more flow separation and higher heating on a trim tab inclined 10 deg relative to the surface. CFD solutions at flight conditions were obtained using an 8-species Mars gas in chemical and thermal non-equilibrium. Laminar and Baldwin-Lomax solutions were used to estimate the effects of the trim tabs and turbulence on heating. A tab extending smoothly from the heatshield flank is not predicted to increase laminar or turbulent heating rates above the reference levels. Laminar heating on a tab deflected 10 deg from the conical heatshield is influenced by flow separation and is up to 35% above the baseline heating rate. The turbulent solution on the inclined tab configuration predicts attached flow and a 43% heating increase above the reference level.

Edquist, Karl T.↗

Gas Chromatograph Method Optimization Trade Study for RESOLVE: 20-meter Column v. 8-meter Column

RESOLVE is the payload on a Class D mission, Resource Prospector, which will prospect for water and other volatile resources at a lunar pole. The RESOLVE payload's primary scientific purpose includes determining the presence of water on the moon in the lunar regolith. In order to detect the water, a gas chromatograph (GC) will be used in conjunction with a mass spectrometer (MS). The goal of the experiment was to compare two GC column lengths and recommend which would be best for RESOLVE's purposes. Throughout the experiment, an Inficon Fusion GC and an Inficon Micro GC 3000 were used. The Fusion had a 20m long column with 0.25mm internal diameter (Id). The Micro GC 3000 had an 8m long column with a 0.32mm Id. By varying the column temperature and column pressure while holding all other parameters constant, the ideal conditions for testing with each column length in their individual instrument configurations were determined. The criteria used for determining the optimal method parameters included (in no particular order) (1) quickest run time, (2) peak sharpness, and (3) peak separation. After testing numerous combinations of temperature and pressure, the parameters for each column length that resulted in the most optimal data given my three criteria were selected. The ideal temperature and pressure for the 20m column were 95 C and 50psig. At this temperature and pressure, the peaks were separated and the retention times were shorter compared to other combinations. The Inficon Micro GC 3000 operated better at lower temperature mainly due to the shorter 8m column. The optimal column temperature and pressure were 70 C and 30psig. The Inficon Micro GC 3000 8m column had worse separation than the Inficon Fusion 20m column, but was able to separate water within a shorter run time. Therefore, the most significant tradeoff between the two column lengths was peak separation of the sample versus run time. After performing several tests, it was concluded that better detection via good peak separation with a longer run time is a better asset than moderate peak separation with a shorter run time. Even given that RESOLVE is highly interested in water and that mission timeline is of significant importance given the short seven-to-ten-day mission timeline, worse detection with an 8m column may lead to overlooking other substances existing on the moon that could advance planetary science. Thus, I recommend the 20m column. However, if mission timeline and water separation are deemed the highest priority, the 8m column should be selected due to its ability to separate water within a shorter run time than the 20m column.

Column↗

The atmosphere of a dirty-clathrate cometary nucleus - A two-phase, multifluid model

The dynamical and thermal structure of a dirty-clathrate cometary nucleus' gas atmosphere is presently given a self-consistent, transonic multifluid solution in which, although the heavy neutron and ion species are treated as a single fluid in the collision-dominated region, the photoproduced H is treated separately. The thermal profile of the atmosphere thus obtained is entirely different from those predicted by the earlier, single-fluid models as well as the multifluid models which assumed equipartition of energy between electrons and ions. While the electron gas, like the neutrals and the ions, cools due to expansion, its main mode of energy loss in the inner coma is by way of inelastic collisions with the predominant H2O molecule. The high electron temperature in the outer coma also decreases the efficiency of electron removal by dissociative recombination, thereby increasing electron density throughout the coma.

Marconi, M. L.↗

Regolith Volatile Characterization (RVC) in RESOLVE

Resource investigation in the lunar poles is of importance to the potential impact of in-situ resource utilization (ISRU). The RESOLVE project developed a payload to investigate the permanently shadowed areas of the lunar poles and demonstrate ISRU technology. As a part of the RESOLVE project, the regolith volatile characterization (RVC) subsystem was designed to examine the release of volatiles from sample cores. The test sample was heated in the reactor to release the volatiles where they were analyzed with gas chromatography. Subsequently, the volatile sample was introduced into the lunar water resource demonstration (LWRD) subsystem where the released hydrogen and water were selectively captured. The objective of the Regolith Volatile Characterization (RVC) subsystem was to heat the crushed core sample and determine the desorption of volatile species of interest. The RVC subsystem encompasses the reactor and the system for volatile analysis. The system was designed to analyze H2, He, CO, CO2, N2, 02, CH4, H2S and H2O. The GC chosen for this work is a Siemens MicroSAM process GC with 3 columns and 8 TCD detectors. Neon was chosen as the carrier gas to enhance the analysis of hydrogen and helium.The limit of detection for the gases is approx.1000ppm for H2, CO. CO2 , N2, O2 and H2 S. The limit of detection for CH4 is approx.4000ppm and the water limit of detection is -10000 ppm with a sample analysis time of 2-3 minutes. These values (with the exception of water and H2S) were determined by dilution of a six gas mixture from Scott Gas (5% CO2, CO, O2, N2, 4% CH4 and H2) using mass flow controllers (MFC5). Water was calibrated at low levels using an in house relative humidity (RH) generator. H 2S and high concentrations of H2 were calibrated by diluting a pure stream of gas with MFCs. Higher concentrations of N2 and 02 were calibrated using Air again diluting with MFCs. There were three modification goals for the GC in EBU2 that would allow this process GC to be used in the field demo for RESOLVE. The first modification was to decrease the weight associated with the GC, this included eliminating the explosion proof case (Figure 1) and replacing it with a lightweight case as well as using an on board COPV tank for the neon carrier gas. The next goal was to add a second oven for the molecular sieve column to allow for dual temperature control during GC operation; the separation of hydrogen and helium is optimum at lower temperatures while the water analysis required higher temperatures creating a competing design requirement. The second oven also allows a lower limit of detection for water quantification and avoids the possibility of water condensing in the GC which could ruin the column characteristics. The final goal was to modify the column arrangement to optimize the system for our specific application. Figure 2 shows the internal details of the module optimized optimized for our field application. The modifications and performance of the gas analysis system will be discussed in detail.

Captain, Janine↗

Gas chromatography: Possible application of advanced instrumentation developed for solar system exploration to space station cabin atmospheres

Gas chromatography (GC) technology was developed for flight experiments in solar system exploration. The GC is a powerful analytical technique with simple devices separating individual components from complex mixtures to make very sensitive quantitative and qualitative measurements. It monitors samples containing mixtures of fixed gases and volatile organic molecules. The GC was used on the Viking mission in support of life detection experiments and on the Pioneer Venus Large Probe to determine the composition of the venusian atmosphere. A flight GC is under development to study the progress and extent of STS astronaut denitrogenation prior to extravehicular activity. Advanced flight GC concepts and systems for future solar system exploration are also studied. Studies include miniature ionization detectors and associated control systems capable of detecting from ppb up to 100% concentration levels. Further miniaturization is investigated using photolithography and controlled chemical etching in silicon wafers. Novel concepts such as ion mobility drift spectroscopy and multiplex gas chromatography are also developed for future flight experiments. These powerful analytical concepts and associated hardware are ideal for the monitoring of cabin atmospheres containing potentially dangerous volatile compounds.

Carle, G. C.↗

Optical Multi-Gas Monitor Technology Demonstration on the International Space Station

There are a variety of both portable and fixed gas monitors onboard the International Space Station (ISS). Devices range from rack-mounted mass spectrometers to hand-held electrochemical sensors. An optical Multi-Gas Monitor has been developed as an ISS Technology Demonstration to evaluate long-term continuous measurement of 4 gases. Based on tunable diode laser spectroscopy, this technology offers unprecedented selectivity, concentration range, precision, and calibration stability. The monitor utilizes the combination of high performance laser absorption spectroscopy with a rugged optical path length enhancement cell that is nearly impossible to misalign. The enhancement cell serves simultaneously as the measurement sampling cell for multiple laser channels operating within a common measurement volume. Four laser diode based detection channels allow quantitative determination of ISS cabin concentrations of water vapor (humidity), carbon dioxide, ammonia and oxygen. Each channel utilizes a separate vertical cavity surface emitting laser (VCSEL) at a different wavelength. In addition to measuring major air constituents in their relevant ranges, the multiple gas monitor provides real time quantitative gaseous ammonia measurements between 5 and 20,000 parts-per-million (ppm). A small ventilation fan draws air with no pumps or valves into the enclosure in which analysis occurs. Power draw is only about 3 W from USB sources when installed in Nanoracks or when connected to 28V source from any EXPRESS rack interface. Internal battery power can run the sensor for over 20 hours during portable operation. The sensor is controlled digitally with an FPGA/microcontroller architecture that stores data internally while displaying running average measurements on an LCD screen and interfacing with the rack or laptop via USB. Design, construction and certification of the Multi-Gas Monitor were a joint effort between Vista Photonics, Nanoracks and NASA-Johnson Space Center (JSC). Vista Photonics developed the core technology and built the sensor. Nanoracks designed, constructed the enclosure, interfaces, and battery power management circuitry, integrated all subsystems into the enclosure, and then managed the certification tests, documentation and manifesting. The unit was calibrated in the JSC Toxicology Laboratory. The Multi-Gas Monitor is manifested to fly as a technology demonstration to the ISS in November 2013 and will operate for at least 6 months with data sent to the ground for evaluation. The primary goal is to demonstrate long term interference free operation in the real spacecraft environment.

Pilgrim, Jeffrey S.↗