Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAMMA FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

GammaPod-A new device dedicated for stereotactic radiotherapy of breast cancer

Purpose: This paper introduces a new external beam radiotherapy device named GammaPod that is dedicated for stereotactic radiotherapy of breast cancer. Methods: The design goal of the GammaPod as a dedicated system for treating breast cancer is the ability to deliver ablative doses with sharp gradients under stereotactic image guidance. Stereotactic localization of the breast is achieved by a vacuum-assisted breast immobilization cup with built-in stereotactic frame. Highly focused radiation is achieved at the isocenter due to the cross-firing from 36 radiation arcs generated by rotating 36 individual Cobalt-60 beams. The dedicated treatment planning system optimizes an optimal path of the focal spot using an optimization algorithm borrowed from computational geometry such that the target can be covered by 90%-95% of the prescription dose and the doses to surrounding tissues are minimized. The treatment plan is intended to be delivered with continuous motion of the treatment couch. In this paper the authors described in detail the gamma radiation unit, stereotactic localization of the breast, and the treatment planning system of the GammaPod system. Results: A prototype GammaPod system was installed at University of Maryland Medical Center and has gone through a thorough functional, geometric, and dosimetric testing. The mechanical and functional performances of the system all meet the functional specifications. Conclusions: An image-guided breast stereotactic radiotherapy device, named GammaPod, has been developed to deliver highly focused and localized doses to a target in the breast under stereotactic image guidance. It is envisioned that the GammaPod technology has the potential to significantly shorten radiation treatments and even eliminate surgery by ablating the tumor and sterilizing the tumor bed simultaneously.

60 APPLIED LIFE SCIENCES↗

Total ionizing dose effect of γ-ray radiation on the switching characteristics and filament stability of HfOx resistive random access memory

The total ionizing dose (TID) effect of gamma-ray (γ-ray) irradiation on HfOx based resistive random access memory was investigated by electrical and material characterizations. The memory states can sustain TID level ∼5.2 Mrad (HfO{sub 2}) without significant change in the functionality or the switching characteristics under pulse cycling. However, the stability of the filament is weakened after irradiation as memory states are more vulnerable to flipping under the electrical stress. X-ray photoelectron spectroscopy was performed to ascertain the physical mechanism of the stability degradation, which is attributed to the Hf-O bond breaking by the high-energy γ-ray exposure.

36 MATERIALS SCIENCE↗

Lung autophagic response following exposure of mice to whole body irradiation, with and without amifostine

Research highlights: {yields} We investigated the effect 6 Gy of WBI on the autophagic machinery of normal mouse lung. {yields} Irradiation induces dysfunction of the autophagic machinery in normal lung, characterized by decreased transcription of the LC3A/Beclin-1 mRNA and accumulation of the LC3A, and p62 proteins. {yields} The membrane bound LC3A-II protein levels increased in the cytosolic fraction (not in the pellet), contrasting the patterns noted after starvation-induced autophagy. {yields} Administration of amifostine, reversed all the LC3A and p62 findings, suggesting protection of the normal autophagic function. -- Abstract: Purpose: The effect of ionizing irradiation on the autophagic response of normal tissues is largely unexplored. Abnormal autophagic function may interfere the protein quality control leading to cell degeneration and dysfunction. This study investigates its effect on the autophagic machinery of normal mouse lung. Methods and materials: Mice were exposed to 6 Gy of whole body {gamma}-radiation and sacrificed at various time points. The expression of MAP1LC3A/LC3A/Atg8, beclin-1, p62/sequestosome-1 and of the Bnip3 proteins was analyzed. Results: Following irradiation, the LC3A-I and LC3A-II protein levels increased significantly at 72 h and 7 days. Strikingly, LC3A-II protein was increased (5.6-fold at 7 days; p < 0.001) only in the cytosolic fraction, but remained unchanged in the membrane fraction. The p62 protein, was significantly increased in both supernatant and pellet fraction (p < 0.001), suggesting an autophagosome turnover deregulation. These findings contrast the patterns of starvation-induced autophagy up-regulation. Beclin-1 levels remained unchanged. The Bnip3 protein was significantly increased at 8 h, but it sharply decreased at 72 h (p < 0.05). Administration of amifostine (200 mg/kg), 30 min before irradiation, reversed all the LC3A and p62 findings on blots, suggesting restoration of the normal autophagic function. The LC3A and Beclin1 mRNA levels significantly declined following irradiation (p < 0.01), whereas Bnip3 levels increased. Conclusions: It is suggested that irradiation induces dysfunction of the autophagic machinery in normal lung, characterized by decreased transcription of the LC3A/Beclin-1 mRNA and accumulation of the LC3A, and p62 proteins. Whether this is due to defective maturation or to aberrant degradation of the autophagosomes requires further investigation.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

GAMMA-RAY BURSTS IN THE FERMI ERA: THE SPECTRAL ENERGY DISTRIBUTION OF THE PROMPT EMISSION

Gamma-ray bursts (GRBs) show evidence of different light curves, duration, afterglows, and host galaxies and explode within a wide redshift range. However, their spectral energy distributions (SEDs) appear to be very similar, showing a curved shape. Band et al. proposed a phenomenological description of the integrated spectral shape for the GRB prompt emission, the so-called Band function. In this Letter, we suggest an alternative scenario to explain the curved shape of GRB SEDs: the log-parabolic model. In comparison with the Band spectral shape our model is statistically favored because it fits the GRB spectra with one parameter less than the Band function and is motivated by a theoretical acceleration scenario. The new Fermi observations of GRBs will be crucial for disentangling these two models.

79 ASTRONOMY AND ASTROPHYSICS↗

SAXS Study of Reversibly Crosslinked Isotactic Polypropylene/clay Nanocomposites

A new route based on reversibly crosslinking reactive extrusion is applied for the development of iPP/clay nanocomposites. Analysis of small-angle X-ray scattering (SAXS) reflections of isotactic polypropylene (iPP)/clay nanocomposites, prepared by two different mixing and chemical crosslinking methods (i.e., conventional and in situ), is presented and results are compared with preceding wide-angle X-ray diffraction (WAXD) results. It is shown that the presence of clay significantly affects the value of long spacing in iPP, as well as the coherence length of lamellar stacks. Results show that the size of the coherently diffracting nanodomains decreases in two stages, first rapidly and then slowly as a function of increasing clay content. This can be attributed to the influence of confined iPP lamellae under the effect of rising number of clay particles. The appearance of the {gamma}-crystalline form in the crosslinked iPP/clay nanocomposites is related with the difficulty in chain folding of iPP chains introduced by the chemical crosslinking process, as well as by the presence of clay particles.

36 MATERIALS SCIENCE↗

Thiazolidinediones inhibit REG I{alpha} gene transcription in gastrointestinal cancer cells

REG (Regenerating gene) I{alpha} protein functions as a growth factor for gastrointestinal cancer cells, and its mRNA expression is strongly associated with a poor prognosis in gastrointestinal cancer patients. We here demonstrated that PPAR{gamma}-agonist thiazolidinediones (TZDs) inhibited cell proliferation and REG I{alpha} protein/mRNA expression in gastrointestinal cancer cells. TZDs inhibited the REG I{alpha} gene promoter activity, via its cis-acting element which lacked PPAR response element and could not bind to PPAR{gamma}, in PPAR{gamma}-expressing gastrointestinal cancer cells. The inhibition was reversed by co-treatment with a specific PPAR{gamma}-antagonist GW9662. Although TZDs did not inhibit the REG I{alpha} gene promoter activity in PPAR{gamma}-non-expressing cells, PPAR{gamma} overexpression in the cells recovered their inhibitory effect. Taken together, TZDs inhibit REG I{alpha} gene transcription through a PPAR{gamma}-dependent pathway. The TZD-induced REG I{alpha} mRNA reduction was abolished by cycloheximide, indicating the necessity of novel protein(s) synthesis. TZDs may therefore be a candidate for novel anti-cancer drugs for patients with gastrointestinal cancer expressing both REG I{alpha} and PPAR{gamma}.

60 APPLIED LIFE SCIENCES↗

A NEW CEPHEID DISTANCE TO THE GIANT SPIRAL M101 BASED ON IMAGE SUBTRACTION OF HUBBLE SPACE TELESCOPE/ADVANCED CAMERA FOR SURVEYS OBSERVATIONS

We accurately determine a new Cepheid distance to M101 (NGC 5457) using archival Hubble Space Telescope (HST)/Advanced Camera for Surveys V and I time series photometry of two fields within the galaxy. We make a slight modification to the ISIS image subtraction package to obtain optimal differential light curves from HST data. We discovered 827 Cepheids with periods between 3 and 80 days, the largest extragalactic sample of Cepheids observed with HST by a factor of two. With this large Cepheid sample, we find that the relative distance of M101 from the Large Magellanic Cloud is {Delta}{mu}{sub LMC} = 10.63 {+-} 0.04 (random) {+-} 0.06 (systematic) mag. If we use the geometrically determined maser distance to NGC 4258 as our distance anchor, the distance modulus of M101 is {mu}{sub 0} = 29.04 {+-} 0.05 (random) {+-} 0.18 (systematic) mag or D = 6.4 {+-} 0.2 (random) {+-} 0.5 (systematic) Mpc. The uncertainty is dominated by the maser distance estimate ({+-}0.15 mag), which should improve over the next few years. We determine a steep metallicity dependence, {gamma}, for our Cepheid sample through two methods, yielding {gamma} = -0.80 {+-} 0.21 (random) {+-} 0.06 (systematic) mag dex{sup -1} and {gamma} = -0.72{sup +0.22}{sub -0.25} (random) {+-} 0.06 (systematic) mag dex{sup -1}. We see marginal evidence for variations in the Wesenheit period-luminosity relation slope as a function of deprojected galactocentric radius. We also use the tip of the red giant branch method to independently determine the distance modulus to M101 of {mu}{sub 0} = 29.05 {+-} 0.06 (random) {+-} 0.12 (systematic) mag.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE EXTREMELY HIGH VELOCITY OUTFLOW FROM THE LUMINOUS YOUNG STELLAR OBJECT G5.89-0.39

We have imaged the extremely high velocity outflowing gas in CO (2-1) and (3-2) associated with the shell-like ultracompact H II region G5.89-0.39 at a resolution of {approx}3'' (corresponding to {approx}4000 AU) with the Submillimeter Array. The integrated high-velocity ({approx}>45 km s{sup -1}) CO emission reveals at least three blueshifted lobes and two redshifted lobes. These lobes belong to two outflows, one oriented N-S, the other NW-SE. The NW-SE outflow is likely identical to the previously detected Br{gamma} outflow. Furthermore, these outflow lobes all clearly show a Hubble-like kinematic structure. For the first time, we estimate the temperature of the outflowing gas as a function of velocity with large velocity gradient calculations. Our results reveal a clear increasing trend of temperature with gas velocity. The observational features of the extremely high velocity gas associated with G5.89-0.39 qualitatively favor the jet-driven bow shock model.

79 ASTRONOMY AND ASTROPHYSICS↗

The Effects of Radiation and Emitted Light Transport on the Positional Response of 11 cm × 42.5 cm × 5.5 cm NaI(Tl) Detectors

Experiments were performed with 30 11 cm x 42.5 x cm 5.5 cm NaI(Tl) detectors to better understand their positional response. Spectra were collected using 0.02 to 0.15 MBq point sources of 241 Am, 137 Cs, 60 Co, and 133 Ba positioned on lines parallel and perpendicular to the long axis of the crystal along both the narrow and wide detector faces as well as at different distances from them. A greater density of positions was sampled at the ends of the detector, and repeated measurements were made to examine potential gain drifts during the experiment. Spectroscopic peak counts, spectroscopic pulse heights, and net counts were analyzed. Empirical equations were fit to the aforementioned data for each specific source energy as a function of source position. In addition, a Monte Carlo radiation transport code was used to simulate the expected positionally variable response based solely upon radiation absorption. The simulated radiation transport efficiency functions were compared to the experimental data. The effects of the geometric radiation efficiency, the attenuation and scattering of emitted light within the scintillation crystal, and combined effects such as non-uniformity of the photomultiplier tube photocathode response and crystal irregularities were then distinguished. Functions describing each effect were derived. The results suggest potential new corrections to data obtained with large scintillation detectors as well as a novel approach to partial positional gamma-ray detection with minimal collimation, given that the energy resolution is within reason for particular photopeaks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bayesian estimation of life parameters in the Weibull distribution.

Development of a Bayesian analysis of the scale and shape parameters in the Weibull distribution and the corresponding reliability function with respect to the usual life-testing procedures. For the scale parameter theta, Bayesian estimates of theta and reliability are obtained for the uniform, exponential, and inverted gamma prior probability densities. Bhattacharya's results (1967) for the one-parameter exponential life-testing distribution are reduced to a special case of these results. A fully Bayesian analysis of both the scale and shape parameters is developed by assuming independent prior distributions; since in the latter case, analytical tractability is not possible, Bayesian estimates are obtained through a conjunction of Monte Carlo simulation and numerical-integration techniques. In both cases, a computer simulation is carried out, and a comparison is made between the Bayesian and the corresponding minimum-variance unbiased, or maximum likelihood, estimates. As expected, the Bayesian estimates are superior.

Canavos, G. C.↗

Resistance heating of Fe and W in diamond-anvil cells

A new method for internally heating a diamond-anvil cell is described. Fine wires of iron or tungsten are resistively heated in a gasketed cell, thus providing a uniformly distributed pressure that can be measured in situ by employing the ruby scale. Temperatures of several thousand degrees have been measured by fitting a black body radiation function to the spectrum of the hot wire taken with an optical multichannel analyzer. Temperatures as high as the melting temperature of tungsten have been achieved. The alpha-gamma and alpha-epsilon phase transitions of iron have been studied, and the results show excellent agreement with previous data obtained with piston-cylinder or externally-heated diamond cells.

Boehler, R.↗

Transient X-rays, gamma-rays and neutrons in space

The various astrophysical sources of transient X-ray, gamma-ray, and neutron emission which can produce significant increases in the high-energy (greater than 1 keV) radiation and particle background flux in space. These sources include solar flares, gamma-ray bursts, supernovae, and other astrophysical transients. The observations of these sources are reviewed, and the expected rate of occurrence of their transient emission is examined as a function of intensity and energy.

Lingenfelter, R. E.↗

Autonomous Radiation Monitoring of Small Vessels

Small private vessels are one avenue by which nuclear materials may be smuggled across international borders. While one can contemplate using the terrestrial approach of radiation portal monitors on the navigable waterways that lead to many ports, these systems are ill-suited to the problem. They require vehicles to pass at slow speeds between two closely-spaced radiation sensors, relying on the uniformity of vehicle sizes to space the detectors, and on proximity to link an individual vehicle to its radiation signature. In contrast to roadways where lanes segregate vehicles, and motion is well controlled by inspection booths; channels, inlets, and rivers present chaotic traffic patterns populated by vessels of all sizes. We have developed a unique solution to this problem based on our portal-less portal monitor instrument that is designed to handle free-flowing traffic on roadways with up to five-traffic lanes. The instrument uses a combination of visible-light and gamma-ray imaging to acquire and link radiation images to individual vehicles. It was recently tested in a maritime setting. In this paper we present the instrument, how it functions, and the results of the recent tests.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

SU-F-P-34: Commission of Enhanced Dynamic Wedge of Varian Truebeam Linac System with Feature Study

Purpose: To evaluate an Enhanced Dynamic Wedge (EDW) as part of machine commission process with feature study. Methods: The EDW system in this study was from a Truebeam, which is the Linear accelerator manufactured by Varian Medical Systems. The EDW feature vectors includes selected elements. These elements were dosimetric output spots check, field size, wedge angles, dose rate, collimator orientation, and different energy settings. Point dose measurement was done by a PTW farmer chamber, and profiles were measured by Gafchromic EBT2 films positing at different depths of the Solidwater based on the study elements. The output spot measurements were done with PTW farmer chamber with Solidwater setting for all orientation and wedge angles in the EDW system. The profiles comparisons were done by IMRT measurement function in RIT software at version 6.3. And the films were scanned by Vidar scanner. Dosimetry calculation were done by using the same Solidwater scanned by GE LightSpeed CT in Eclipse Treatment Planning System (TPS). Then measurements were compared to simulation results in TPS. Results: The energy average percentage difference between chamber measurement and TPS was 0.16% with standard deviation (SD) at 0.93%. For selected features, the average percentage difference between film measurement and computation was 0.93% with SD at 1.55% in horizontal profiles, and 1.18% with SD at 0.98% at vertical profiles. The average gamma difference for film measurement and TPS computing results was at 0.924 with SD at 0.314. Conclusion: A feature vector was developed to describe the commission of EDW, and developing a complete set of features for sufficiency of commission of a LINAC function could provide optimal commission instance with acceptable confident level of clinical application of the machine. Given the institution specific vector pattern and big data process, it could provide wide range clinical outcome comparison information in application of EDW.

60 APPLIED LIFE SCIENCES↗

First Evaluation of the Biologic Effectiveness Factors of Boron Neutron Capture Therapy (BNCT) in a Human Colon Carcinoma Cell Line

Purpose: DNA lesions produced by boron neutron capture therapy (BNCT) and those produced by gamma radiation in a colon carcinoma cell line were analyzed. We have also derived the relative biologic effectiveness factor (RBE) of the neutron beam of the RA-3- Argentine nuclear reactor, and the compound biologic effectiveness (CBE) values for p-boronophenylalanine ({sup 10}BPA) and for 2,4-bis ({alpha},{beta}-dihydroxyethyl)-deutero-porphyrin IX ({sup 10}BOPP). Methods and Materials: Exponentially growing human colon carcinoma cells (ARO81-1) were distributed into the following groups: (1) BPA (10 ppm {sup 10}B) + neutrons, (2) BOPP (10 ppm {sup 10}B) + neutrons, (3) neutrons alone, and (4) gamma rays ({sup 60}Co source at 1 Gy/min dose-rate). Different irradiation times were used to obtain total absorbed doses between 0.3 and 5 Gy ({+-}10%) (thermal neutrons flux = 7.5 10{sup 9} n/cm{sup 2} sec). Results: The frequency of micronucleated binucleated cells and the number of micronuclei per micronucleated binucleated cells showed a dose-dependent increase until approximately 2 Gy. The response to gamma rays was significantly lower than the response to the other treatments (p < 0.05). The irradiations with neutrons alone and neutrons + BOPP showed curves that did not differ significantly from, and showed less DNA damage than, irradiation with neutrons + BPA. A decrease in the surviving fraction measured by 3-(4,5-dimetiltiazol-2-il)-2,5-difeniltetrazolium bromide (MTT) assay as a function of the absorbed dose was observed for all the treatments. The RBE and CBE factors calculated from cytokinesis block micronucleus (CBMN) and MTT assays were, respectively, the following: beam RBE: 4.4 {+-} 1.1 and 2.4 {+-} 0.6; CBE for BOPP: 8.0 {+-} 2.2 and 2.0 {+-} 1; CBE for BPA: 19.6 {+-} 3.7 and 3.5 {+-} 1.3. Conclusions: BNCT and gamma irradiations showed different genotoxic patterns. To our knowledge, these values represent the first experimental ones obtained for the RA-3 in a biologic model and could be useful for future experimental studies for the application of BNCT to colon carcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD)-induced cytotoxicity accompanied by oxidative stress in rat Sertoli cells: Possible role of mitochondrial fractions of Sertoli cells

TCDD, as an endocrine disruptor, is known to impair testicular functions and fertility. To elucidate the mechanism(s) underlying the testicular effects of TCDD, the potential toxicity of TCDD on Sertoli cells was investigated. Furthermore, the study aims to delineate whether mitochondrial fractions of Sertoli cells are involved in mediating the testicular effects of TCDD. Adult rat Sertoli cells were incubated with (5, 10 or 15 nM) of TCDD for 6, 12 or 24 h. Cell viability, lactate and LDH leakage into media along with lipid peroxidation, ROS generation, SOD, CAT, GPx, GR, {gamma}-GT and {beta}-glucuronidase activities, GSH content and {Delta}{psi}{sub m} were measured. Superoxide anion production, COX and cardiolipin content were measured in mitochondrial fractions. Cell viability was significantly decreased while lactate and LDH leakage into media were increased. ROS generation along with lipid peroxidation was also increased. SOD, CAT, GPx, GR activities and GSH content were significantly decreased. {gamma}-GT and {beta}-glucuronidase activities were also decreased. Superoxide anion production was increased while COX activity and cardiolipin content were decreased in mitochondrial fractions. Moreover, the {Delta}{psi}{sub m} was significantly decreased as measured in Sertoli cells. In conclusion, TCDD impairs Sertoli cell functions and this effect is, at least in part, attributed to oxidative stress. We have also found that TCDD increases mitochondrial superoxide anion production and decreases {Delta}{psi}{sub m}, COX activity and mitochondrial cardiolipin content. Our findings suggest that mitochondria may play an important role in ROS production, leading to the TCDD-induced oxidative stress response and resulting toxicological consequences in rat Sertoli cells.

60 APPLIED LIFE SCIENCES↗

Gamma-ray continuum and line observations of SN 1987A

The Caltech gamma-ray imaging telescope observed the hard X-ray and gamma-ray emission from SN 1987A as it evolved between 1987 May and 1989 April, in a series of four balloon flights from Alice Springs, NT, Australia. Observations of the Crab Nebula and Pulsar provided in-flight data on pointing accuracy and instrument function for each flight. Results presented here include our measurements on November 18, 1987 (D268) and April 12, 1988 (D414) of both line emission at 847 and 1238 keV from the decay of Co-56, and Compton-scattered continuum above 50 keV. Upper limits for both line and continuum emission were obtained on May 20, 1987 (D86) and April 4, 1989 (D771). For the D268 and D414 continuum measurements, our results are best-fit by a differential power law of the form dN/dE = kE exp -gamma (sq cm s keV) for the energy range 50-800 keV. Our corresponding line measurements were fit with Gaussian profiles, containing additional terms for the underlying continuum. We compare our flux measurements and upper limits to those from other experiments and to predictions of theoretical models.

Palmer, D. M.↗