Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Finite Element Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Second-Order Invariant Domain Preserving ALE Approximation of Euler Equations

Abstract An invariant domain preserving arbitrary Lagrangian-Eulerian method for solving non-linear hyperbolic systems is developed. The numerical scheme is explicit in time and the approximation in space is done with continuous finite elements. The method is made invariant domain preserving for the Euler equations using convex limiting and is tested on various benchmarks.

Guermond, Jean-Luc↗

Experimental and Numerical Analysis on the Distortion of Parts Made of 20MnCr5 by Hot Metal Forming

For high performance applications, shafts and gears made of 20MnCr5 (AISI 5120) are manufactured in large numbers every year. Inhomogeneities in the material properties, process perturbations and asymmetries in shape and operation setups provide a potential for the distortion of parts, often released by heat treatment. In this contribution experimental results on the distortion of shafts and the dishing of disk-like gear wheel blanks are presented. The numerical analysis of the hot-rolling process allowed to trace a peculiar segregation distribution at the cross-section of the bars back to the casting process, and to identify an asymmetric strain distribution which may be the main cause for shaft distortion. For the dishing of the disks a correlation to the resulting distribution of the material flow was found and, a process perturbation parameter identified which is assumed to be responsible for the observed material flow variation.

36 MATERIALS SCIENCE↗

Self-Pierce Riveting Through 3 Sheet Metal Combinations

One way to reduce the CO{sub 2} emissions in automotives is to reduce the weight of the Body-In-White. One easy to achieve the weight reduction is to replace steel sheet materials with Al alloys, which is 3 times lighter. One issue is the joining process, especially with combinations between steel grades and AL alloys. Example of combination of mixed material combinations (Al-steel) might be found in the door structure. The reason is because of the AL alloys worthier crash performance so the automotive manufacturer might want to use crash impact beams made by high strength steels in a AL intensive door structure. The joining process between aluminum and steel are problematic due it's not possible to use traditional spot-welding technologies due to the materials total difference in microstructure characteristics as well thermal properties. To overcome this issue then mechanical as well adhesion joining are frequently used. This paper describes a development process and subsequently analysis of a self-pierce rivet (SPR) process between 3 sheet metal combinations. The multi-material combinations in this study were a combination of ultra high strength steels sheets (DP1000) and a Al-alloy (AA 6014). The analysis of the SPR process, in sense of mechanical strengths, has been done by peel- and shear tests. To reduce the amount of future physical tests a virtual FE-model has been developed for the process. This FE model of the process has been subsequently used to analyze the mechanical strength during plastic deformation. By using inverse analysis a correct contact algorithm has been evaluated that would predict the binding force between the rivet and sheet under a deformation process. With this new virtual model it will not only possible to analyze and develop the SPR process but also to achieve the final strength of the joint.

36 MATERIALS SCIENCE↗

Monitoring of mechanical changes in a pipe assembly with complex geometry using multi-mode acoustic signals

Guided wave ultrasonic testing has been widely used for nondestructive and long-range evaluation of diverse mechanical structures, such as pipes and plates. In general, a large number of guided wave modes exist even in the simplest geometries, and they exhibit highly dispersive characteristics. Thus, sophisticated excitation methods and elaborate modal analyses need to be implemented to excite, acquire, and process well-defined pure modes as part of such a measurement method. If the interrogated structure has complex geometry, for example, with cross-sectional variations or multiple joints, the utilization of pure modes becomes significantly more difficult. To overcome this difficulty, this paper proposes the use of multi-mode, multi-frequency guided waves for long-range inspection of structures with arbitrarily complex geometries. Furthermore, using broadband chirp signals and multi-mode time–frequency analysis in a prototypical complex pipe assembly that includes multiple pipe diameters, elbows, and flange connections, we experimentally show sensitive detection of mechanical changes (both material addition and loss). In addition, we demonstrate that the complexity of the structure can be modeled in the digital domain with sufficient detail to allow accurate numerical simulation of the acoustic response using this method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Finite element simulation of microphotonic lasing system

We present a method for performing time domain simulations of a microphotonic system containing a four level gain medium based on the finite element method. This method includes an approximation that involves expanding the pump and probe electromagnetic fields around their respective carrier frequencies, providing a dramatic speedup of the time evolution. Finally, we present a two dimensional example of this model, simulating a cylindrical spaser array consisting of a four level gain medium inside of a metal shell.

36 MATERIALS SCIENCE↗

Comparison of multimesh hp-FEM to interpolation and projection methods for spatial coupling of reactor thermal and neutron diffusion calculations

Multiphysics solution challenges are legion within the ?eld of nuclear reactor design and analysis. One major issue concerns the coupling between heat and neutron ?ow (neutronics) within the reactor assembly. These phenomena are usually very tightly interdependent, as large amounts of heat are quickly produced with an increase in ?ssion events within the fuel, which raises the temperature that a?ects the neutron cross section of the fuel. Furthermore, there typically is a large diversity of time and spatial scales between mathematical models of heat and neutronics. Indeed, the di?erent spatial resolution requirements often lead to the use of very di?erent meshes for the two phenomena. As the equations are coupled, one must take care in exchanging solution data between them, or signi?cant error can be introduced into the coupled problem. We propose a novel approach to the discretization of the coupled problem on di?erent meshes based on an adaptive multimesh higher-order ?nite element method (hp-FEM), and compare it to popular interpolation and projection methods. We show that the multimesh hp-FEM method is signi?cantly more accurate than the interpolation and projection approaches considered in this study.

97 MATHEMATICS AND COMPUTING↗

An n -material thresholding method for improving integerness of solutions in topology optimization

It is common in solving topology optimization problems to replace an integer-valued characteristic function design field with the material volume fraction field, a real-valued approximation of the design field that permits "fictitious" mixtures of materials during intermediate iterations in the optimization process. This is reasonable so long as one can interpolate properties for such materials and so long as the final design is integer valued. For this purpose, we present a method for smoothly thresholding the volume fractions of an arbitrary number of material phases which specify the design. This method is trivial for two-material design problems, for example, the canonical topology design problem of specifying the presence or absence of a single material within a domain, but it becomes more complex when three or more materials are used, as often occurs in material design problems. We take advantage of the similarity in properties between the volume fractions and the barycentric coordinates on a simplex to derive a thresholding, method which is applicable to an arbitrary number of materials. As we show in a sensitivity analysis, this method has smooth derivatives, allowing it to be used in gradient-based optimization algorithms. Finally, we present results, which show synergistic effects when used with Solid Isotropic Material with Penalty and Rational Approximation of Material Properties material interpolation functions, popular methods of ensuring integerness of solutions.

42 ENGINEERING↗

Deformational Features and Microstructure Evolution of Copper Fabricated by a Single Pass of the Elliptical Cross-Section Spiral Equal-Channel Extrusion (ECSEE) Process

The objectives of this work are to study the deformational feature, textures, microstructures, and dislocation configurations of ultrafine-grained copper processed by the process of elliptical cross-section spiral equal-channel extrusion (ECSEE). The deformation patterns of simple shear and pure shear in the ECSEE process were evaluated with the analytical method of geometric strain. The influence of the main technical parameters of ECSEE die on the effective strain distribution on the surface of ECSEE-fabricated samples was examined by the finite element simulation. The high friction factor could improve the effective strain accumulation of material deformation. Moreover, the pure copper sample fabricated by ECSEE ion shows a strong rotated cube shear texture. The refining mechanism of the dislocation deformation is dominant in copper processed by a single pass of ECSEE. The inhomogeneity of the micro-hardness distribution on the longitudinal section of the ECSEE-fabricated sample is consistent with the strain and microstructure distribution features.

36 MATERIALS SCIENCE↗

First in-core simultaneous measurements of nuclear heating and thermal neutron flux obtained with the innovative mobile calorimeter CALMOS inside the OSIRIS reactor

Nuclear heating inside a MTR reactor has to be known in order to design and to run irradiation experiments which have to fulfill target temperature constraints. This measurement is usually carried out by calorimetry. The innovative calorimetric system, CALMOS, has been studied and built in 2011 for the 70 MWth OSIRIS reactor operated by CEA. Thanks to a new type of calorimetric probe, associated to a specific displacement system, it provides measurements along the fissile height and above the core. This development required preliminary modelling and irradiation of mock-ups of the calorimetric probe in the ex-core area, where nuclear heating rate does not exceed 2 W.g{sup -1}. The calorimeter working modes, the different measurement procedures allowed with such a new probe, the main modeling and experimental results and expected advantages of this new technique have been already presented. However, these first in-core measurements were not performed beyond 6 W.g{sup -1}, due to an inside temperature limitation imposed by a safety authority requirement. In this paper, we present the first in-core simultaneous measurements of nuclear heating and conventional thermal neutron flux obtained by the CALMOS device at the 70 MW nominal reactor power. For the first time, this experimental system was operated in nominal in-core conditions, with nominal neutron flux up to 2.7 10{sup 14} n.cm{sup -2}.s{sup -1} and nuclear heating up to 12 W.g{sup -1}. A comprehensive measurement campaign carried out from 2013 to 2015 inside all accessible irradiation locations of the core, allowed to qualify definitively this new device, not only in terms of measurement ability but also in terms of reliability. After a brief reminder of the calorimetric cell configuration and displacement system specificities, first nuclear heating distributions at nominal power are presented and discussed. In order to reinforce the heating evaluation, a systematic comparison is made between results obtained by different methods, the probe calibration coefficient and the zero method. Thermal neutron flux evaluation from the SPND signal processing required a specific TRIPOLI-4 Monte Carlo calculation which has been performed with the precise CALMOS cell geometry. In addition, the Finite Element model for temperatures map prediction inside the calorimetric cell has been upgraded with the recent experimental data obtained up to 12 W.g{sup -1}. The Kc coefficient, taking into account nonlinearities with regard to the calibration, has been reevaluated so as to make relevant measurements up to the nominal reactor power. Finally, the experience feedback acquired until now with this first CALMOS version led us to improvement perspectives. A second device is currently under manufacturing and main technical options chosen for this second version are presented. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of different methods for measuring thermal conductivities

Two different methods for the measurement of the thermal conductivity have been applied to a glass (borosilicate) bulk sample. The first method was in the steady-state using an arrangement of gold wires on the sample to create a thermal gradient and to measure the temperatures locally. This allows one to calculate the in-plane thermal conductivity of the sample. The same wire arrangement was also used for a 3{omega}-measurement of the direction-independent bulk thermal conductivity. The 3{omega}-approach is based on periodical heating and a frequency dependent analysis of the temperature response. The results of both methods are in good agreement with each other for this isotropic material, if thermal and radiative losses are accounted for. Our results demonstrate that especially in the case of thin-film measurements, finite element analysis has to be applied to correct for heat losses due to geometry and radiation. In this fashion, the wire positions can be optimized in order to minimize measurement errors.

36 MATERIALS SCIENCE↗

SU-E-T-58: Calculation of Dose Distribution of Accuboost Brachytherapy in Deformable Polyvinil Alcohol Breast Phantom Using Biomechanical Modeling and Monte Carlo Simulation

Purpose: the accuboost is the most modern method of breast brachytherapy that is a boost method in compressed tissue by a mammography unit. the dose distribution in uncompressed tissue, as compressed tissue is important that should be characterized. Methods: In this study, the mechanical behavior of breast in mammography loading, the displacement of breast tissue and the dose distribution in compressed and uncompressed tissue, are investigated. Dosimetry was performed by two dosimeter methods of Monte Carlo simulations using MCNP5 code and thermoluminescence dosimeters. For Monte Carlo simulations, the dose values in cubical lattice were calculated using tally F6. The displacement of the breast elements was simulated by Finite element model and calculated using ABAQUS software, from which the 3D dose distribution in uncompressed tissue was determined. The geometry of the model is constructed from MR images of 6 volunteers. Experimental dosimetery was performed by placing the thermoluminescence dosimeters into the polyvinyl alcohol breast equivalent phantom and on the proximal edge of compression plates to the chest. Results: The results indicate that using the cone applicators would deliver more than 95% of dose to the depth of 5 to 17mm, while round applicator will increase the skin dose. Nodal displacement, in presence of gravity and 60N forces, i.e. in mammography compression, was determined with 43% contraction in the loading direction and 37% expansion in orthogonal orientation. Finally, in comparison of the acquired from thermoluminescence dosimeters with MCNP5, they are consistent with each other in breast phantom and in chest's skin with average different percentage of 13.7±5.7 and 7.7±2.3, respectively. Conclusion: The major advantage of this kind of dosimetry is the ability of 3D dose calculation by FE Modeling. Finally, polyvinyl alcohol is a reliable material as a breast tissue equivalent dosimetric phantom that provides the ability of TLD dosimetry for validation.

60 APPLIED LIFE SCIENCES↗

Liquid hydrogen storage system for heavy duty trucks: Configuration, performance, cost, and safety

In this work, we investigate the potential of liquid hydrogen storage (LH 2 ) on-board Class-8 heavy duty trucks to resolve many of the range, weight, volume, refueling time and cost issues associated with 350 or 700-bar compressed H 2 storage in Type-3 or Type-4 composite tanks. We present and discuss conceptual storage system configurations capable of supplying H 2 to fuel cells at 5-bar with or without on-board LH 2 pumps. Structural aspects of storing LH 2 in double walled, vacuum insulated, and low-pressure Type-1 tanks are investigated. Structural materials and insulation methods are discussed for service at cryogenic temperatures and mitigation of heat leak to prevent LH 2 boiloff. Failure modes of the liner and shell are identified and analyzed using the regulatory codes and detailed finite element (FE) methods. The conceptual systems are subjected to a Failure modes and effects analysis (FMEA) and a safety, codes, and standards (SCS) review to rank failures and identify safety gaps. The results indicate that the conceptual systems can reach 19.6% usable gravimetric capacity, 40.9 g-H 2 /L usable volumetric capacity and $174-183/kg-H 2 cost (2016 USD) when manufactured 100,000 systems annually.

08 HYDROGEN↗

Coupling a Cellular Automaton Model with a Finite Element Model for Simulating Deformation and Recrystallization of a Low-Carbon Micro-alloyed Steel During Hot Compression

This study simulated the dynamic recrystallization (DRX) of a 2.25Cr-1Mo-0.25V steel by coupling a cellular automaton (CA) method with a finite element (FE) model. A secondary development program (SDP) on DEFORM-2D was carried out and the stress strain response, dislocation density evolution and DRX were considered. In this way, an interaction between the microstructural evolution and the deformation behavior can be taken into account. The values of temperature, strain and strain rate from the FE analysis were passed to the CA model. In turn, the recrystallized grain size and volume fraction of DRX predicted by the CA model were passed back to the FE model, which influenced the flow stress. To validate the SDP, the predicted loads and flow stress were compared with the experimental values, which show a good agreement. Then, the SDP program was used to simulate the microstructural evolution. Morphological characteristic, recrystallized grain size and volume fraction of DRX were predicted and compared with experimental data. The results show that the comparison is in a good agreement, which indicates the SDP is reliable.

36 MATERIALS SCIENCE↗

Fragmentation Prediction for a Brittle Ceramic: a Two-Scale Model Approach

Glass and oxide-ceramic radioactive material forms (e.g., PuO{sub 2}) are susceptible to brittle fracture during handling and transportation. Fracture of these materials may result in the generation of fragments small enough to become airborne, and thus easily dispersed and inhaled. Entrainment and dispersal of particles with dimensions less than 10 μm is generally anticipated under normal aerodynamic conditions. The assessment of the risk to the public and the environment from these materials due to events resulting in their fracture is based on the determination of the source term for environmental release. This source term is typically quantified by an airborne release fraction (ARF) and a respirable fraction (RF) of material generated by a given event. While the recommended empirical bounding values prove satisfactory to comply with the regulatory process for handling and transportation of these materials, they are based on test data for only a few materials subjected to a limited range of loading conditions. Because the final state of fragmentation (in terms of the size and distribution of fragments) is strongly dependent not only on the properties of the material and the energetic loading conditions that lead to breakup, but also on the many intrinsic length scales associated with fragmentation, it is difficult to precisely predict fragmentation characteristics for other brittle solid wastes forms subjected to a wider range of loading conditions based on the test data alone. The purpose of this manuscript is to present a two-scale modeling approach that may be used to simulate the dynamic fragmentation of brittle solid radioactive material forms subjected to general loading and boundary conditions. The method provides the resulting fragment characteristics (average size and size distribution) across the entire fragment range of interest. At the macro-scale, the approach uses a gradient damage elastic continuum mechanics material model within a finite element framework to simulate dynamic fracture under general loading and boundary conditions. Results from the macroscopic calculations are passed to a one-dimensional (1-D) lower length scale model that incorporates the relevant fine scale effects to determine the micro-scale fragmentation. This 1-D micro-scale fragmentation model simulates the internal crack nucleation and opening processes to predict the average fragment size and the fragment size distribution as a function of the material properties, loading conditions, and microscopic characteristic length scale of the material. Results from the lower length scale model are then combined with the macro-scale model fragmentation information to determine the resulting fragment size distribution spanning both length scales. This two-scale model has been exercised on a representative problem drawn from experimental studies, consisting of an impact of a falling weight onto a brittle ceramic. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

A general framework for substructuring-based domain decomposition methods for models having nonlocal interactions [including apppendix B]

A rigorous mathematical framework is provided for a substructuring-based domain-decomposition approach for nonlocal problems that feature interactions between points separated by a finite distance. Here, by substructuring it is meant that a traditional geometric configuration for local partial differential equation problems is used in which a computational domain is subdivided into non-overlapping subdomains. In the nonlocal setting, this approach is substructuring-based in the sense that those subdomains interact with neighboring domains over interface regions having finite volume, in contrast to the local PDE setting in which interfaces are lower dimensional manifolds separating abutting subdomains Key results include the equivalence between the global, single-domain nonlocal problem and its multi-domain reformulation, both at the continuous and discrete levels. These results provide the rigorous foundation necessary for the development of efficient solution strategies for nonlocal domain-decomposition methods.

97 MATHEMATICS AND COMPUTING↗

Benchmarking numerical methods for impact and cratering applications

Large scale computational models are important for studying impact cratering events that are prevalent both on Earth and, more broadly, in this solar system. To address these problems, models must reliably account for both large length scales (e.g., kilometers) and relatively long time scales (hundreds of seconds). This work benchmarks two such approaches, a more traditional hydrodynamics approach and a finite-discrete element method (FDEM), for impact cratering applications. Both 2D and 3D results are discussed for two different impact velocities, 5 km/s and 20 km/s, striking normal to the target and, for 3D simulations, 45° from vertical. In addition, comparisons to previously published data are presented. Finally, differences in how these methods model damage are discussed. Ultimately, both approaches show successful modeling of several different impact scenarios.

58 GEOSCIENCES↗

Large breast compressions: Observations and evaluation of simulations

Purpose: Several methods have been proposed to simulate large breast compressions such as those occurring during x-ray mammography. However, the evaluation of these methods against real data is rare. The aim of this study is to learn more about the deformation behavior of breasts and to assess a simulation method. Methods: Magnetic resonance (MR) images of 11 breasts before and after applying a relatively large in vivo compression in the medial direction were acquired. Nonrigid registration was employed to study the deformation behavior. Optimal material properties for finite element modeling were determined and their prediction performance was assessed. The realism of simulated compressions was evaluated by comparing the breast shapes on simulated and real mammograms. Results: Following image registration, 19 breast compressions from 8 women were studied. An anisotropic deformation behavior, with a reduced elongation in the anterior-posterior direction and an increased stretch in the inferior-superior direction was observed. Using finite element simulations, the performance of isotropic and transverse isotropic material models to predict the displacement of internal landmarks was compared. Isotropic materials reduced the mean displacement error of the landmarks from 23.3 to 4.7 mm, on average, after optimizing material properties with respect to breast surface alignment and image similarity. Statistically significantly smaller errors were achieved with transverse isotropic materials (4.1 mm, P=0.0045). Homogeneous material models performed substantially worse (transverse isotropic: 5.5 mm; isotropic: 6.7 mm). Of the parameters varied, the amount of anisotropy had the greatest influence on the results. Optimal material properties varied less when grouped by patient rather than by compression magnitude (mean: 0.72 vs 1.44). Employing these optimal materials for simulating mammograms from ten MR breast images of a different cohort resulted in more realistic breast shapes than when using established material models. Conclusions: Breasts in the prone position exhibited an anisotropic compression behavior. Transverse isotropic materials with an increased stiffness in the anterior-posterior direction improved the prediction of these deformations and produced more realistic mammogram simulations from MR images.

60 APPLIED LIFE SCIENCES↗