Ab initio study of charge-transfer dynamics in collisions of C{sup 2+} ions with hydrogen chloride

Ab initio quantum chemistry molecular calculations followed by a semiclassical dynamical treatment in the keV collision energy range have been developed for the study of the charge-transfer process in collisions of C{sup 2+} ions with hydrogen chloride. The mechanism has been investigated in detail in connection with avoided crossings between states involved in the reaction. A simple mechanism driven by a strong nonadiabatic coupling matrix element has been pointed out for this process. A comparative analysis with the halogen fluoride target corresponding to a similar electronic configuration shows a quite different charge-transfer mechanism leading to a very different behavior of the cross sections. Such behavior may be correlated to specific nonadiabatic interactions observed in these collision systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal-noise-limited crystalline whispering-gallery-mode resonator for laser stabilization

We have stabilized an external cavity diode laser to a whispering gallery mode resonator formed by a protrusion of a single-crystal magnesium fluoride cylinder. The cylinder's compact dimensions ((less-or-similar sign)1 cm{sup 3}) reduce the sensitivity to vibrations and simplify the stabilization of its temperature in a compact setup. In a comparison to an ultrastable laser used for precision metrology we determine a minimum Allan deviation of 20 Hz at an optical wavelength of 972 nm, corresponding to a relative Allan deviation of 6x10{sup -14}, at an integration time of 100 ms. This level of instability is compatible with the limits imposed by fundamental fluctuations of the material's refractive index at room temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Production of excitons in grazing collisions of protons with LiF surfaces: An onion model

In this work we evaluate the production of excitons of a lithium fluoride crystal induced by proton impact in the intermediate and high energy regime (from 100 keV to 1 MeV). A simple model is proposed to account for the influence of the Coulomb grid of the target by dressing crystal ions to transform them in what we call onions. The excited states of these onions can be interpreted as excitons. Within this model, total cross section and stopping power are calculated by using the first Born and the continuum distorted-wave (CDW) eikonal initial-state (EIS) approximations. We found that between 7 and 30 excitons per incident proton are produced in grazing collisions with LiF surfaces, becoming a relevant mechanism of inelastic transitions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Spectral properties of orbital polarons in Mott insulators

We address the spectral properties of Mott insulators with orbital degrees of freedom, and investigate cases where the orbital symmetry leads to Ising-type superexchange in the orbital sector. The paradigm of a hole propagating by its coupling to quantum fluctuations, known from the spin t-J model, then no longer applies. We find instead that when one of the two orbital flavors is immobile, as in the Falicov-Kimball model, trapped orbital polarons coexist with free hole propagation emerging from the effective three-site hopping in the regime of large on-site Coulomb interaction U. The spectral functions are found analytically in this case within the retraceable path approximation in one and two dimensions. On the contrary, when both of the orbitals are active, as in the model for t2g electrons in two dimensions, we find propagating polarons with incoherent scattering dressing the moving hole and renormalizing the quasiparticle dispersion. Here, the spectral func- tions, calculated using the self-consistent Born approximation, are anisotropic and depend on the orbital flavor. Unbiased conclusions concerning the spectral properties are established by comparing the above results for the orbital t-J models with those obtained using the variational cluster approximation or exact diagonalization for the corresponding Hubbard models. The present work makes predictions concerning the essential features of photoemission spectra of certain fluorides and vanadates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Elastic and magnetic effects on the infrared phonon spectra on MnF

We measured the temperature-dependent infrared reflectivity spectra of MnF{sub 2} between 4 and 600 K. We show that the phonon spectrum undergoes a clear renormalization at T{sub N}. The ab initio calculation we performed on this compound accurately predicts the magnitude and the direction of the changes in the phonon parameters across the antiferromagnetic transition, showing that they are mainly induced by the magnetic order. In this material, we found that the dielectric constant is mostly from phonon origin. The large change in the lattice parameters with temperature seen by x-ray diffraction as well as the A{sub 2u} phonon softening below T{sub N} indicate that magnetic order induced distortions in MnF{sub 2} are compatible with the ferroelectric instabilities observed in TiO{sub 2}, FeF{sub 2} and other rutile-type fluorides. This study also shows the anomalous temperature evolution of the lower energy E{sub u} mode in the paramagnetic phase, which can be compared to that of the B{sub 1g} phonon seen by Raman spectroscopy in many isostructural materials. This was interpreted as being a precursor of a phase transition from rutile to CaCl{sub 2} structure which was observed under pressure in ZnF{sub 2}.

60 APPLIED LIFE SCIENCES↗

Direct probe of Mott-Hubbard to charge-transfer insulator transition and electronic structure evolution in transition-metal systems

We report the most direct experimental verification of Mott-Hubbard and charge-transfer insulators through x-ray emission spectroscopy in transition-metal (TM) fluorides. The p-d hybridization features in the spectra allow a straightforward energy alignment of the anion-2p and metal-3d valence states, which visually shows the difference between the two types of insulators. Furthermore, in parallel with the theoretical Zaanen-Sawatzky-Allen diagram, a complete experimental systematics of the 3d Coulomb interaction and the 2p-3d charge-transfer energy is reported and could serve as a universal experimental trend for other TM systems including oxides.

25 ENERGY STORAGE↗

Evaluate Scintillation Response Over a Continuous Energy Region

A recently developed fast analysis technique utilizing a time of flight (TOF) telescope is demonstrated to obtain relevant quantitative data on material scintillation response to energetic He particles. With superior energy resolution and fast response of the TOF telescope, energy of individual particle before impinging on a scintillating crystal can be determined with a high counting rate, which allows quantitative study of material performance over a continuous energy range in a relatively short time. Scintillation performances in terms of light output, nonlinearity and energy resolution in bismuth germinate (BGO) and europium-doped calcium fluoride (CaF2:Eu) Crystals are demonstrated, and the corresponding energy resolution is compared with gamma-ray tests on the same crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluorination mechanisms of Al{sub 2}O{sub 3} and Y{sub 2}O{sub 3} surfaces irradiated by high-density CF{sub 4}/O{sub 2} and SF{sub 6}/O{sub 2} plasmas

Fluorination of Al{sub 2}O{sub 3} and Y{sub 2}O{sub 3} surfaces was investigated by irradiating high-density, helicon-wave CF{sub 4}/O{sub 2} and SF{sub 6}/O{sub 2} plasmas. The Al{sub 2}O{sub 3} surface bombarded by high-flux positive ions of the CF{sub 4}/O{sub 2} plasma was fluorinated significantly. On contrast, Y{sub 2}O{sub 3} was less fluorinated than Al{sub 2}O{sub 3} when they were irradiated by the same CF{sub 4}/O{sub 2} plasma. The analysis of the Al{sub 2}O{sub 3} surface irradiated by the CF{sub 4}/O{sub 2} plasma suggests that the fluorination is triggered by reactions between fluorocarbon deposit and Al-O bonding with the assistance of ion bombardment. On the other hand, irradiation of the SF{sub 6}/O{sub 2} plasma induced less significant fluorination on the Al{sub 2}O{sub 3} surface. This suggests a lower reaction probability between sulfur fluoride deposit and Al-O bonding. The difference in the fluorination of the Al{sub 2}O{sub 3} and Y{sub 2}O{sub 3} surfaces induced by the irradiations of the CF{sub 4}/O{sub 2} and SF{sub 6}/O{sub 2} plasmas is understood by comparing the bonding energies of C-O, S-O, Al-O, and Y-O.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface modification of phyllosilicate minerals by fluorination methods

The effect of fluorination on various types of phyllosilicate minerals has been investigated. Two different fluorination techniques have been used: direct F{sub 2} gas and cold radio frequency plasma involving c-C{sub 4}F{sub 8} or O{sub 2}/CF{sub 4} mixtures. The modifications of the surface composition and properties have been followed mostly by x-ray photoelectron spectroscopy (XPS). Depending of the fluorination reagents, a reactive etching process involving M-F bonding occurs (direct F{sub 2} gas; O{sub 2}-CF{sub 4} rf plasma) or a carbon fluoride deposition takes place (c-C{sub 4}F{sub 8} rf plasma). In the case of F{sub 2}-gas treated minerals, Si 2p XPS signal accounts for the presence of fluorinated Si environments.

36 MATERIALS SCIENCE↗

Size control of nanopores formed on SiO{sub 2} glass by swift-heavy-ion irradiation and its application to highly sensitive biomolecular detection

Swift-heavy-ion irradiation creates latent tracks in SiO{sub 2} glass and nanopores with a high aspect ratio can be formed along these ion paths by selective etching of the latent tracks using hydrogen fluoride (HF) vapor. Here we report that the size of nanopores can easily be controlled by simply changing the temperature of the HF solution generating the vapor and/or that of the SiO{sub 2} glass exposed to the vapor. Furthermore, this method of size control was used to produce SiO{sub 2} glass sheets with nanopores of different sizes and number densities for use as the waveguide layer in the sensing plates for a waveguide-mode sensor. In comparison with nonperforated plates, the increased surface area due to the formation of nanopores was found to create up to a tenfold increase in sensitivity.

36 MATERIALS SCIENCE↗

Metal oxide morphology in argon-assisted glancing angle deposition

Glancing angle deposition (GLAD) is a thin film deposition technique capable of fabricating columnar architectures such as posts, helices, and chevrons with control over nanoscale film features. Argon bombardment during deposition modifies the GLAD process, producing films with new morphologies which have shown promise for sensing and photonic devices. The authors report modification of column tilt angle, film density, and specific surface area for 12 different metal oxide and fluoride film materials deposited using Ar-assisted GLAD. For the vapor flux/ion beam geometry and materials studied here, with increasing argon flux, the column tilt increases, film density increases, and specific surface area decreases. With a better understanding of the nature of property modification and the mechanisms responsible, the Ar-assisted deposition process can be more effectively targeted towards specific applications, including birefringent thin films or photonic crystal square spirals.

36 MATERIALS SCIENCE↗

Novel materials for laser refrigeration

The status of optical refrigeration of rare-earth-doped solids is reviewed, and the various factors that limit the performance of current laser-cooling materials are discussed. Efficient optical refrigeration is possible in materials for which {Dirac_h}{omega}{sub max} < E{sub p}/8, where {Dirac_h}{omega}{sub max} is the maximum phonon energy of the host material and E{sub p} is the pump energy of the rare-earth dopant. Transition-metal and OH{sup -}impurities at levels >100 ppb are believed to be the main factors for the limited laser-cooling performance in current materials. The many components of doped ZBLAN glass pose particular processing challenges. Binary fluoride glasses such as YF{sub 3}-LiF are considered as alternatives to ZBLAN. The crystalline system KPb{sub 2}CI{sub 5} :Dy{sup 3+} is identified as a prime candidate for high-efficiency laser cooling.

36 MATERIALS SCIENCE↗

High temperature thermographic measurements of laser heated silica

In situ spatial and temporal surface temperature profiles of CO{sub 2} laser-heated silica were obtained using a long wave infrared (LWIR) HgCdTe camera. Solutions to the linear diffusion equation with volumetric and surface heating are shown to describe the temperature evolution for a range of beam powers, over which the peak surface temperature scales linearly with power. These solutions were used with on-axis steady state and transient experimental temperatures to extract thermal diffusivity and conductivity for a variety of materials, including silica, spinel, sapphire, and lithium fluoride. Experimentally-derived thermal properties agreed well with reported values and, for silica, thermal conductivity and diffusivity are shown to be approximately independent of temperature between 300 and 2800K. While for silica our analysis based on a temperature independent thermal conductivity is shown to be accurate, for other materials studied this treatment yields effective thermal properties that represent reasonable approximations for laser heating. Implementation of a single-wavelength radiation measurement in the semi-transparent regime is generally discussed, and estimates of the apparent temperature deviation from the actual outer surface temperature are also presented. The experimental approach and the simple analysis presented yield surface temperature measurements that can be used to validate more complex physical models, help discriminate dominant heat transport mechanisms, and to predict temperature distribution and evolution during laser-based material processing.

42 ENGINEERING↗

Thermoluminescence dosimetry measurements of brachytherapy sources in liquid water

Radiation therapy dose measurements are customarily performed in liquid water. The characterization of brachytherapy sources is, however, generally based on measurements made with thermoluminescence dosimeters (TLDs), for which contact with water may lead to erroneous readings. Consequently, most dosimetry parameters reported in the literature have been based on measurements in water-equivalent plastics, such as Solid Water. These previous reports employed a correction factor to transfer the dose measurements from a plastic phantom to liquid water. The correction factor most often was based on Monte Carlo calculations. The process of measuring in a water-equivalent plastic phantom whose exact composition may be different from published specifications, then correcting the results to a water medium leads to increased uncertainty in the results. A system has been designed to enable measurements with TLDs in liquid water. This system, which includes jigs to support water-tight capsules of lithium fluoride in configurations suitable for measuring several dosimetric parameters, was used to determine the correction factor from water-equivalent plastic to water. Measurements of several {sup 125}I and {sup 131}Cs prostate brachytherapy sources in liquid water and in a Solid Water phantom demonstrated a correction factor of 1.039{+-}0.005 at 1 cm distance. These measurements are in good agreement with a published value of this correction factor for an {sup 125}I source.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of a lithium formate EPR dosimetry system for dose measurements around {sup 192}Ir brachytherapy sources

A dosimetry system using lithium formate monohydrate (HCO{sub 2}Li{center_dot}H{sub 2}O) as detector material and electron paramagnetic resonance (EPR) spectroscopy for readout has been used to measure absorbed dose distributions around clinical {sup 192}Ir sources. Cylindrical tablets with diameter of 4.5 mm, height of 4.8 mm, and density of 1.26 g/cm{sup 3} were manufactured. Homogeneity test and calibration of the dosimeters were performed in a 6 MV photon beam. {sup 192}Ir irradiations were performed in a PMMA phantom using two different source models, the GammaMed Plus HDR and the microSelectron PDR-v1 model. Measured absorbed doses to water in the PMMA phantom were converted to the corresponding absorbed doses to water in water phantoms of dimensions used by the treatment planning systems (TPSs) using correction factors explicitly derived for this experiment. Experimentally determined absorbed doses agreed with the absorbed doses to water calculated by the TPS to within {+-}2.9%. Relative standard uncertainties in the experimentally determined absorbed doses were estimated to be within the range of 1.7%-1.3% depending on the radial distance from the source, the type of source (HDR or PDR), and the particular absorbed doses used. This work shows that a lithium formate dosimetry system is well suited for measurements of absorbed dose to water around clinical HDR and PDR {sup 192}Ir sources. Being less energy dependent than the commonly used thermoluminescent lithium fluoride (LiF) dosimeters, lithium formate monohydrate dosimeters are well suited to measure absorbed doses in situations where the energy dependence cannot easily be accounted for such as in multiple-source irradiations to verify treatment plans. Their wide dynamic range and linear dose response over the dose interval of 0.2-1000 Gy make them suitable for measurements on sources of the strengths used in clinical applications. The dosimeter size needs, however, to be reduced for application to single-source dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

In-patient to isocenter KERMA ratios in CT

Purpose: To estimate in-patient KERMA for specific organs in computed tomography (CT) scanning using ratios to isocenter free-in-air KERMA obtained using a Rando phantom.Method: A CT scan of an anthropomorphic phantom results in an air KERMA K at a selected phantom location and air kerma K{sub CT} at the CT scanner isocenter when the scan is repeated in the absence of the phantom. The authors define the KERMA ratio (R{sub K}) as K/ K{sub CT}, which were experimentally determined in a Male Rando Phantom using lithium fluoride chips (TLD-100). R{sub K} values were obtained for a total of 400 individual point locations, as well as for 25 individual organs of interest in CT dosimetry. CT examinations of Rando were performed on a GE LightSpeed Ultra scanner operated at 80 kV, 120 kV, and 140 kV, as well as a Siemens Sensation 16 operated at 120 kV. Results: At 120 kV, median R{sub K} values for the GE and Siemens scanners were 0.60 and 0.64, respectively. The 10th percentile R{sub K} values ranged from 0.34 at 80 kV to 0.54 at 140 kV, and the 90th percentile R{sub K} values ranged from 0.64 at 80 kV to 0.78 at 140 kV. The average R{sub K} for the 25 Rando organs at 120 kV was 0.61 {+-} 0.08. Average R{sub K} values in the head, chest, and abdomen showed little variation. Relative to R{sub K} values in the head, chest, and abdomen obtained at 120 kV, R{sub K} values were about 12% lower in the pelvis and about 58% higher in the cervical spine region. Average R{sub K} values were about 6% higher on the Siemens Sensation 16 scanner than the GE LightSpeed Ultra. Reducing the x-ray tube voltage from 120 kV to 80 kV resulted in an average reduction in R{sub K} value of 34%, whereas increasing the x-ray tube voltage to 140 kV increased the average R{sub K} value by 9%. Conclusions: In-patient to isocenter relative KERMA values in Rando phantom can be used to estimate organ doses in similar sized adults undergoing CT examinations from easily measured air KERMA values at the isocenter (free in air). Conversion from in-patient air KERMA values to tissue dose would require the use of energy-appropriate conversion factors.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-308: Systematic Characterization of the Energy Response of Different LiF TLD Crystals for Dosimetry Applications

Purpose: The thermoluminiscense dosimeters (TLDs) are widely used in personal and clinical dosimetry due to its small size, good sensitivity and tissue equivalence, among other advantages. This study presents the characterization of Lithium Fluoride based TLDs, in terms of their absorbed dose response to successive irradiation cycles in a broad range of beam energies, measured under reference conditions. Methods: Four types of Harshaw TLD chips were used: TLD-100, TLD-600 TLD-700 and 100-H. They were irradiated with 10 photon beams of different energy spectrums, from 28 kVp to 18MV (in 30 consecutive cycles for 6 and 18 MV). Results: It was found that the response of the dosimetric system was stabilized (less than ±3%) after 10 cycles for TLD-600 and TLD-700. In the case of TLD-100 and TLD-100H this dependence was not observed. A decreased response to increasing beam energy in terms of absorbed dose to water was observed, as expected, except for TLD-100H which showed the opposite behavior. The less energy dependent detector was the TLD-100H exhibiting a maximum deviation of 12%. The highest variation observed was 33% for TLD-100. The study allowed the determination of calibration factors in absorbed dose for a wide range of energies and materials for different dosimetric applications, such as in-vivo dosimetry during imaging and radiotherapy. Conclusion: The study allowed the determination of calibration factors in absorbed dose for a wide range of energies and materials for different dosimetric applications, such as in-vivo dosimetry during imaging and radiotherapy.

60 APPLIED LIFE SCIENCES↗

TU-F-12A-06: BEST IN PHYSICS (IMAGING) - A Novel Catheter-Based Radionuclide Imaging System to Characterize Atherosclerotic Plaque

Purpose: Atherosclerosis underlies coronary artery diseases, the leading cause of death in the United States and worldwide. In this study, we developed a novel catheter-based radionuclide imaging (CRI) system to image 18F-fluorodeoxyglucose (18F-FDG), a radionuclide, a marker of vascular inflammation, in murine carotid arteries and characterized the system for spatial resolution from multiple scintillating materials. Methods: The catheter system includes 35 mm and 8 mm fixed focal length lenses, which are subsequently connected to a CMOS camera and fiber holder. The distal ferrule of an image bundle is terminated with a wide-angle lens. The novelty of this system is a scintillating balloon with a crystal tip in the front of the wide angle lens to image light from the decay of 18F-FDG emission signal. The scintillating balloon is fabricated from 1mL of silicone RTV catalyst mixed with 1 mL base and 50 mg/mL calcium fluoride doped with Europium (CaF2:Eu). To identify the optimal scintillating materials with respect to resolution, we calculated modulation transfer function (MTF) of Yttrium Aluminum Garnet doped with Cerium (YAG:Ce), anthracene, and CaF2:Eu phosphors using a thin line optical phantom (Fig. 1a-1b). Macrophage-rich FVB murine atherosclerotic carotid plaque model (n = 4) was used in ex vivo experiments. Confirmatory imaging was also performed by an external optical imaging system (IVIS-200). Results: Analysis of the different phosphors (Fig 1b) showed that CaF2:Eu enabled the best resolution of 1.2μm. The CRI system visualized 18F-FDG in atherosclerotic plaques (Fig. 1d). The ligated left carotid (LR) artery exhibited 4× higher 18F-FDG signal intensity compared to the non-ligated right carotid (negative control) artery (1.65×10{sup 2} ±4.07×10{sup 1} vs. 4.44×10{sup 1}±2.17×10{sup 0}, A.U., p = 0.005) and confirmed with IVIS-200 (Fig. 1d). Conclusion: This CRI system enables high-resolution and sensitive detection of 18F-FDG uptake by murine atherosclerotic plaques.