Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Systematic Uncertainties in the NOvA \nu_\mu-Disappearance Analysis

As the NOvA long-baseline neutrino oscillation experiment takes more data, systematic uncertainty begins to more heavily impact the oscillation analyses. The largest effects are calibration on calorimetric energy, detector modeling on muon energy scale, and near-detector pileup on normalization of the far-detector expectation. Cross-section systematics will be discussed in another poster. Detailed studies have justified previous systematics as too conservative and suggested smaller values. Focused study of detector modeling using dE/dx and external measurements constrain the calibration and energy scale uncertainties. A novel technique is used to assess the impact of activity from neutrino activity piling up over signal, where a simulated neutrino is overlaid into both data and simulation. The difference in efficiency of selecting that single neutrino among data and simulated spills then dominates the normalization systematic.

Alion, Tyler [Sussex U.]↗

Relative Cost-Effectiveness of Electricity and Transportation Policies as a Means to Reduce CO2 Emissions in the United States: A Multi-Model Assessment

Two common energy policy instruments in the United States are tax incentives and technology standards. Although these instruments have been shown to be less cost-effective as a means to reduce CO2 emissions than direct emissions pricing mechanisms, it can be challenging to compare the CO2 emissions reduction costs of such policies across sectors, given the wide range in estimates for any given policy and inconsistencies in how such estimates are constructed across studies. This study addresses this analytical gap by simultaneously comparing the cost-effectiveness of policies across the electricity and transportation sectors using three publicly available US energy system models (EM-NEMS, ReEDS, and GCAM-USA). Four policies are explicitly compared: wind and solar tax credits, a renewable portfolio standard (RPS), a renewable fuel standard (RFS), and an electric vehicle (EV) tax credit. An economy-wide carbon tax is used as a benchmark for cost-effectiveness. Results from this study confirm prior insights about the cost-effectiveness of economy-wide carbon pricing relative to sectoral instruments but also reveal several novel insights about particular sectoral policies. Specifically, this study finds that (1) current electricity tax incentives provide uneven support for wind and solar technologies, (2) despite known inefficiencies, renewable energy policies in the electricity sector are less expensive than earlier estimates due to technology advancement and changes in market conditions, (3) within transportation, an expanded RFS with increasing advanced biofuel targets is more cost-effective than an EV tax credit extension under plausible assumptions, (4) EV incentives lead to a rebound in conventional vehicle fuel economy that further erodes cost-effectiveness, and (5) the change in policy costs over time is not known a priori, but the relative cost ordering among these policies does not depend on the timeframe of analysis. These results are largely robust to the underlying modeling framework, increasing the confidence with which they can be applied to climate policy evaluation.

economics↗

Modeling Savings for ENERGY STAR Smart Home Energy Management Systems

The objective of this study was to develop a repeatable and defensible methodology to analyze the energy savings for Home Energy Management Systems (HEMS) that meets the minimum requirements for certification under ENERGY STAR ® Smart Home Energy Management System (SHEMS) Version 1. Mandatory connected loads include a smart thermostat, two smart lights, and one smart power strip or smart outlet. Control strategies must include feedback to occupants through an in-home display, user programming, occupancy sensor-based controls, and responsiveness to utility signals such as demand response programs. Several occupant behavior patterns were selected to quantify the range of energy savings potential for a HEMS with this basic functionality. A literature review was conducted to establish realistic room-by-room occupancy levels and usage patterns for connected devices. A series of event-driven hourly profiles were created, followed by adjustments based on application of HEMS control strategies to thermostats, interior lighting, and plug load schedules. EnergyPlus modeling was performed using these hourly schedules in three locations (Boston, Houston, and Phoenix) to examine climate dependence of energy savings. Total site energy savings ranged from 4.3 to 27.1 MBtu/year (7%-35%), and utility bill savings ranged from $\$$123 to $\$$670/year (6%-29%). The highest predicted savings was realized by occupants that were not energy conscious prior to HEMS installation, but highly engaged with the HEMS controls once the system was installed. The smart thermostat accounted for most of the savings, followed by the smart power strip. Smart lighting did not save a significant amount of energy in our analysis, based on an assumption that efficient LEDs with no standby power would normally be installed anyway.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Templated Approach for Multi-Physics Modeling of Hybrid Energy Systems in Modelica

A prototypical hybrid energy system (HES) couples a primary thermal power generator (i.e., nuclear power plant) with one or more additional subsystems beyond the traditional balance of plant electricity generation system. The definition and architecture of an HES can be adapted based on the needs and opportunities of a given local market. For example, locations in need of potable water may be best served by coupling a desalination plant to the HES. A location near an oil refinery may have a need for emission-free hydrogen production. The flexible, multidomain capabilities of Modelica are being used to investigate the dynamics (e.g., thermal hydraulics and electrical generation/consumption) of such a hybrid system. This paper examines the simulation infrastructure created to enable the coupling of multiphysics subsystem models for HES studies. A demonstration of a tightly coupled nuclear hybrid energy system implemented using the Modelica based infrastructure is presented for two representative cases. An appendix is also included providing a step-by-step procedure for using the template-based infrastructure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Turbine Electrified Energy Management with Model Predictive Control

Affordability, sustainability, and efficiency are primary motivators driving the future of NASA aeronautics research. These factors are realized, in part, through the development and implementation of new technologies and strategies enabling efficient, affordable, and safe hybrid-electric aircraft. Research supporting electrified aircraft propulsion control systems exemplifies such new methodologies, offering varied opportunities to integrate electric machines with gas-based turbine engines. For hybrid-electric propulsion systems, current conceptual architectures seek to introduce energy storage and exploit electrical power system components to assist gas-based system components. Capitalizing on the electric machines in hybridized engines, Turbine Electrified Energy Management (TEEM) is a control approach that enhances transient operability to improve overall propulsion and vehicle efficiency by injecting or extracting power from engine shafts. Traditionally implemented with proportional-integral (PI) control, this study expands the application of TEEM by presenting model predictive control (MPC) schemes to execute the TEEM concept. Via cost function design and constraint selection, the transient operability goals for TEEM are considered in the controller designs. The proposed MPCs are simulated on a nonlinear turbofan engine model at two environmental conditions, with comparisons drawn to a baseline PI. Performance is evaluated using compressor maps and two TEEM-specific metrics: transient stack usage and transient excursion integral. Simulation results reveal the developed schemes perform comparably to the benchmark controller and can be implemented in two distinct configurations. Potential modifications for future investigations include cost function measures that optimize energy use, additional performance effectiveness measures, and battery storage capabilities.

Elyse D. Hill↗

Reactive Transport Modeling of Aquifer Thermal Energy Storage System at Stockton, NJ

This is the modeling data (input/output files of TOUGHREACT 4.10) used to simulate the reactive transport processes of the Aquifer Thermal Energy Storage (ATES) operations at Stockton University, NJ. Readme.txt lists all the files. TOUGHREACT 4.10 requires to reproduce the modeling output. The modeling data in this submission is related to the Aquifer Injection for Energy Storage purposes outlined in "Reactive Transport Modeling of Aquifer Thermal Energy Storage System at Stockton, NJ During Seasonal Operations".

15 GEOTHERMAL ENERGY↗

Stochastic Modeling of Overtime Occupancy and Its Application in Building Energy Simulation and Calibration

Overtime is a common phenomenon around the world. Overtime drives both internal heat gains from occupants, lighting and plug-loads, and HVAC operation during overtime periods. Overtime leads to longer occupancy hours and extended operation of building services systems beyond normal working hours, thus overtime impacts total building energy use. Current literature lacks methods to model overtime occupancy because overtime is stochastic in nature and varies by individual occupants and by time. To address this gap in the literature, this study aims to develop a new stochastic model based on the statistical analysis of measured overtime occupancy data from an office building. A binomial distribution is used to represent the total number of occupants working overtime, while an exponential distribution is used to represent the duration of overtime periods. The overtime model is used to generate overtime occupancy schedules as an input to the energy model of a second office building. The measured and simulated cooling energy use during the overtime period is compared in order to validate the overtime model. A hybrid approach to energy model calibration is proposed and tested, which combines ASHRAE Guideline 14 for the calibration of the energy model during normal working hours, and a proposed KS test for the calibration of the energy model during overtime. The developed stochastic overtime model and the hybrid calibration approach can be used in building energy simulations to improve the accuracy of results, and better understand the characteristics of overtime in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Life Prediction Model for Grid-Connected Li-ion Battery Energy Storage System

Lithium-ion (Li-ion) batteries are being deployed on the electrical grid for a variety of purposes, such as to smooth fluctuations in solar renewable power generation. The lifetime of these batteries will vary depending on their thermal environment and how they are charged and discharged. To optimal utilization of a battery over its lifetime requires characterization of its performance degradation under different storage and cycling conditions. Aging tests were conducted on commercial graphite/nickel-manganese-cobalt (NMC) Li-ion cells. A general lifetime prognostic model framework is applied to model changes in capacity and resistance as the battery degrades. Across 9 aging test conditions from 0oC to 55oC, the model predicts capacity fade with 1.4% RMS error and resistance growth with 15% RMS error. The model, recast in state variable form with 8 states representing separate fade mechanisms, is used to extrapolate lifetime for example applications of the energy storage system integrated with renewable photovoltaic (PV) power generation.

25 ENERGY STORAGE↗

Technology Solutions Case Study: High-Performance Walls in Hot-Dry Climates

In this project,the Alliance for Residential Building Innovation (ARBI) team worked with builders in California to implement wall assemblies meeting a U-value lower than 0.050 Btu/h-ft2-°F. ARBI and its project team members helped builders identify preferred wall designs that met the requirements of their architects, structural engineers, and purchasing agents and that were acceptable to their subcontractors. Construction methods were observed and documented and construction costs obtained from builders were used to inform cost estimates for a range of advanced wall system types and insulation types. Wall framing types of 2 × 6 (16- and 24-in. on center [o.c.]) and double stud were modeled in Building Energy Optimization (BEopt™) software with cavity insulation levels ranging from R-19 to R-33 (double stud) and exterior rigid insulation of R-4, R-6, and R-8.

ARBI↗

JPL Energy Consumption Program (ECP) documentation: A computer model simulating heating, cooling and energy loads in buildings

The engineering manual provides a complete companion documentation about the structure of the main program and subroutines, the preparation of input data, the interpretation of output results, access and use of the program, and the detailed description of all the analytic, logical expressions and flow charts used in computations and program structure. A numerical example is provided and solved completely to show the sequence of computations followed. The program is carefully structured to reduce both user's time and costs without sacrificing accuracy. The user would expect a cost of CPU time of approximately $5.00 per building zone excluding printing costs. The accuracy, on the other hand, measured by deviation of simulated consumption from watt-hour meter readings, was found by many simulation tests not to exceed + or - 10 percent margin.

Lansing, F. L.↗

Mid-IR Imaging of Orion BN/KL: Modeling of Physical Conditions and Energy Balance

We have modeled two mid-infrared imaging photometry data sets to determine the spatial distribution of physical conditions in the BN/KL (Becklin-Neugebauer / Kleinmann-Low) infrared complex. We observed the BN/KL region using the 10-meter Keck I telescope and the LWS (Living With a Star) in the direct imaging mode, over a 13 inch by 19 inch field . We also modeled images obtained with COMICS (Cooled Mid-Infrared Camera and Spectrometer, Kataza et al. 2000) at the 8.2-meter SUBARU telescope, over a total field of view [which] is 31 inches by 41 inches in a total of nine bands: 7.8, 8.8, 9.7, 10.5, 11.7, 12.4, 18.5, 20.8 and 24.8 microns with 1-micron bandwidth interference filters.

Gezari, Daniel↗

Modeled Results of Four Residential Energy Efficiency Measure Packages for Deriving Advanced Building Construction Research Targets

The Advanced Building Construction (ABC) Initiative from the U.S. Department of Energy Building Technologies Office is working to accelerate industrialized construction innovations for decarbonizing buildings. To inform performance and cost targets for research under the ABC Initiative, this analysis used the ResStock™ tool to evaluate the energy savings, utility bill impacts, and carbon emissions impacts of four simulated upgrade packages with specific target performance levels on a large sample of residential dwelling units (approximately 550,000) representative of the U.S. housing stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Inspection of 56 Fe γ -Ray angular distributions as a function of incident neutron energy using optical model approaches

Neutron inelastic scattering cross sections measured directly through (n,n) or deduced from g-ray production cross sections following inelastic neutron scattering (n,n0) are a focus of basic and applied research at the University of Kentucky Accelerator Laboratory (www.pa.uky.edu/accelerator). For nuclear data applications, angle-integrated cross sections are desired over a wide range of fast neutron energies. Several days of experimental beam time are required for a data set at each incident neutron energy, which limits the number of angular distributions that can be measured in a reasonable amount of time. Approximations can be employed to generate cross sections with a higher energy resolution, since at 125°, the a 2 P 2 term of the Legendre expansion is identically zero and the a 4 P 4 is assumed to be very small. Provided this assumption is true, a single measurement at 125o would produce the g-ray production cross section. Finally, this project tests these assumptions and energy dependences using the codes CINDY/SCAT and TALYS/ECIS06/SCAT. It is found that care must be taken when interpreting g-ray excitation functions as cross sections when the incident neutron energy is <1000 keV above threshold or before the onset of feeding.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diagnostic of Horndeski theories

We study the effects of Horndeski models of dark energy on the observables of the large-scale structure in the late time universe. A novel classification into Late dark energy , Early dark energy and Early modified gravity scenarios is proposed, according to whether such models predict deviations from the standard paradigm persistent at early time in the matter domination epoch. We discuss the physical imprints left by each specific class of models on the effective Newton constant μ, the gravitational slip parameter η, the light deflection parameter Σ and the growth function f σ{sub 8} and demonstrate that a convenient way to dress a complete portrait of the viability of the Horndeski accelerating mechanism is via two, redshift-dependent, diagnostics: the μ( z ) − Σ( z ) and the f σ{sub 8}( z ) − Σ( z ) planes. If future, model-independent, measurements point to either Σ − 1 < 0 at redshift zero or μ − 1 < 0 with Σ − 1 > 0 at high redshifts or μ − 1 > 0 with Σ − 1 < 0 at high redshifts, Horndeski theories are effectively ruled out. If f σ{sub 8} is measured to be larger than expected in a ΛCDM model at z > 1.5 then Early dark energy models are definitely ruled out. On the opposite case, Late dark energy models are rejected by data if Σ < 1, while, if Σ > 1, only Early modifications of gravity provide a viable framework to interpret data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evidence for Dark Energy from the Cosmic Microwave Background Alone Using the Atacama Cosmology Telescope Lensing Measurements

For the first time, measurements of the cosmic microwave background radiation (CMB) alone favor cosmologies with w = -1 dark energy over models without dark energy at a 3.2-sigma level. We demonstrate this by combining the CMB lensing deflection power spectrum from the Atacama Cosmology Telescope with temperature and polarization power spectra from the "Wilkinson Microwave Anisotropy Probe. The lensing data break the geometric degeneracy of different cosmological models with similar CMB temperature power spectra. Our CMB-only measurement of the dark energy density Omega(delta) confirms other measurements from supernovae, galaxy clusters and baryon acoustic oscillations, and demonstrates the power of CMB lensing as a new cosmological tool.

Sherwin, Blake D.↗

Validation of a Crystal Plasticity Model Using High Energy Diffraction Microscopy

High energy diffraction microscopy is used to measure the crystallographic orientation and evolution of lattice strain in an Al Li alloy. The relative spatial arrangement of the several pancake-shaped grains in a tensile sample is determined through in situ and ex situ techniques. A model for crystal plasticity with continuity of lattice spin is posed, where grains are represented by layers in a finite element mesh following the arrangement indicated by experiment. Comparison is drawn between experiment and simulation.

Beaudoin, A. J.↗

Stochastic Modelling of Wireless Energy Transfer

This study investigates the efficiency of a new method of powering remote sensors by the means of wireless energy transfer. The increased use of sensors for data collection comes with the inherent cost of supplying power from sources such as power cables or batteries. Wireless energy transfer technology eliminates the need for power cables or periodic battery replacement. The time and cost of setting up or expanding a sensor network will be reduced while allowing sensors to be placed in areas where running power cables or battery replacement is not feasible. This paper models wireless channels for power and data separately. Smart scheduling for the data channel is proposed to avoid transmitting data on a noisy channel where the probability of data loss is high to improve power efficiency. Analytical models have been developed and verified using simulations.

Veilleux, Shaun↗

Methodology for interpretable reinforcement learning model for HVAC energy control

Deep reinforcement learning (DRL) approaches have been used in various application areas to improve efficiency, optimization, or automation. However, very little is known about how the DRL algorithms make decisions and what features affect their performance. Using a case study of a DRL based Heating, Ventilation and Air Conditioning (HVAC) optimization methodology, we demonstrate how we can address these challenges by applying interpretability tools and systematically exploring the model inputs for better understanding the DRL behaviour and decision making process. We developed a methodology for interpretable reinforcement learning and evaluated our approach in real-world house located in Knoxville, TN. Our findings explain the reasoning behind DRL-based optimization decisions under different circumstances which has been discussed and confirmed by the experts in the field.

Kotevska, Olivera↗