Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRONIC MODULE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Superconducting dome in ferroelectric-type materials from soft mode instability

Here we present a minimal theory of superconductivity enhancement in ferroelectric-type materials. Simple expressions for the optical mode responsible for the soft mode transition are assumed. A key role is played by the anharmonic phonon damping which is modulated by an external control parameter (electron doping or mechanical strain) causing the appearance of the soft mode. It is shown that the enhancement in the superconducting critical temperature T c upon approaching the ferroelectric transition from either side is due to the Stokes electron-phonon scattering processes promoted by strong phonon damping effects.

36 MATERIALS SCIENCE↗

Characterization of Quantum Frequency Processors

Frequency-bin qubits possess unique synergies with wavelength-multiplexed lightwave communications, suggesting valuable opportunities for quantum networking with the existing fiber-optic infrastructure. Although the coherent manipulation of frequency-bin states requires highly controllable multi-spectral-mode interference, the quantum frequency processor (QFP) provides a scalable path for gate synthesis leveraging standard telecom components. Here, we summarize the state of the art in experimental QFP characterization. Distinguishing between physically motivated “open box” approaches that treat the QFP as a multiport interferometer, and “black box” approaches that view the QFP as a general quantum operation, we highlight the assumptions and results of multiple techniques, including quantum process tomography of a tunable beamsplitter—to our knowledge the first full process tomography of any frequency-bin operation. Our findings should inform future characterization efforts as the QFP increasingly moves beyond proof-of-principle tabletop demonstrations toward integrated devices and deployed quantum networking experiments.

42 ENGINEERING↗

Systems biology defines the biological significance of redox‐active proteins during cellulose degradation in an aerobic bacterium

Summary Microbial depolymerization of plant cell walls contributes to global carbon balance and is a critical component of renewable energy. The genomes of lignocellulose degrading microorganisms encode diverse classes of carbohydrate modifying enzymes, although currently there is a paucity of knowledge on the role of these proteins in vivo . We report the comprehensive analysis of the cellulose degradation system in the saprophytic bacterium C ellvibrio japonicus . Gene expression profiling of C . japonicus demonstrated that three of the 12 predicted β‐1,4 endoglucanases ( cel5A , cel5B , and cel45A ) and the sole predicted cellobiohydrolase ( cel6A ) showed elevated expression during growth on cellulose. Targeted gene disruptions of all 13 predicted cellulase genes showed that only cel5B and cel6A were required for optimal growth on cellulose. Our analysis also identified three additional genes required for cellulose degradation: lpmo10B encodes a lytic polysaccharide monooxygenase ( LPMO ), while cbp2D and cbp2E encode proteins containing carbohydrate binding modules and predicted cytochrome domains for electron transfer. Cj LPMO10B oxidized cellulose and C bp2 D demonstrated spectral properties consistent with redox function. Collectively, this report provides insight into the biological role of LPMOs and redox proteins in cellulose utilization and suggests that C . japonicus utilizes a combination of hydrolytic and oxidative cleavage mechanisms to degrade cellulose.

Gardner, Jeffrey G.↗

Enhanced photocathode performance through optimization of film thickness and substrate

Here, it is shown that the efficiency of photoelectron emission may be enhanced, several-fold, through optimization of photocathode film thickness and appropriate substrate configuration. Such an enhancement is based on a careful consideration of wave interference effects in the film and the consequent modulation of the absorption profiles and electron emission probabilities. Finally, the inadequacy of the well-known Lambert-Beer law for modeling photon absorption in thin films is also discussed.

42 ENGINEERING↗

Statistical variability and confidence intervals for planar dose QA pass rates

Purpose: The most common metric for comparing measured to calculated dose, such as for pretreatment quality assurance of intensity-modulated photon fields, is a pass rate (%) generated using percent difference (%Diff), distance-to-agreement (DTA), or some combination of the two (e.g., gamma evaluation). For many dosimeters, the grid of analyzed points corresponds to an array with a low areal density of point detectors. In these cases, the pass rates for any given comparison criteria are not absolute but exhibit statistical variability that is a function, in part, on the detector sampling geometry. In this work, the authors analyze the statistics of various methods commonly used to calculate pass rates and propose methods for establishing confidence intervals for pass rates obtained with low-density arrays. Methods: Dose planes were acquired for 25 prostate and 79 head and neck intensity-modulated fields via diode array and electronic portal imaging device (EPID), and matching calculated dose planes were created via a commercial treatment planning system. Pass rates for each dose plane pair (both centered to the beam central axis) were calculated with several common comparison methods: %Diff/DTA composite analysis and gamma evaluation, using absolute dose comparison with both local and global normalization. Specialized software was designed to selectively sample the measured EPID response (very high data density) down to discrete points to simulate low-density measurements. The software was used to realign the simulated detector grid at many simulated positions with respect to the beam central axis, thereby altering the low-density sampled grid. Simulations were repeated with 100 positional iterations using a 1 detector/cm{sup 2} uniform grid, a 2 detector/cm{sup 2} uniform grid, and similar random detector grids. For each simulation, %/DTA composite pass rates were calculated with various %Diff/DTA criteria and for both local and global %Diff normalization techniques. Results: For the prostate and head/neck cases studied, the pass rates obtained with gamma analysis of high density dose planes were 2%-5% higher than respective %/DTA composite analysis on average (ranging as high as 11%), depending on tolerances and normalization. Meanwhile, the pass rates obtained via local normalization were 2%-12% lower than with global maximum normalization on average (ranging as high as 27%), depending on tolerances and calculation method. Repositioning of simulated low-density sampled grids leads to a distribution of possible pass rates for each measured/calculated dose plane pair. These distributions can be predicted using a binomial distribution in order to establish confidence intervals that depend largely on the sampling density and the observed pass rate (i.e., the degree of difference between measured and calculated dose). These results can be extended to apply to 3D arrays of detectors, as well. Conclusions: Dose plane QA analysis can be greatly affected by choice of calculation metric and user-defined parameters, and so all pass rates should be reported with a complete description of calculation method. Pass rates for low-density arrays are subject to statistical uncertainty (vs. the high-density pass rate), but these sampling errors can be modeled using statistical confidence intervals derived from the sampled pass rate and detector density. Thus, pass rates for low-density array measurements should be accompanied by a confidence interval indicating the uncertainty of each pass rate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of superficial dosimetry between treatment planning system and measurement for several breast cancer treatment techniques

Purpose: Dosimetric accuracy in radiation treatment of breast cancer is critical for the evaluation of cosmetic outcomes and survival. It is often considered that treatment planning systems (TPS) may not be able to provide accurate dosimetry in the buildup region. This was investigated in various treatment techniques such as tangential wedges, field-in-field (FF), electronic compensator (eComp), and intensity-modulated radiotherapy (IMRT). Methods: Under Institutional Review Board (IRB) exemption, radiotherapy treatment plans of 111 cases were retrospectively analyzed. The distance between skin surface and 95% isodose line was measured. For measurements, Gafchromic EBT2 films were used on a humanoid unsliced phantom. Multiple layers of variable thickness of superflab bolus were placed on the breast phantom and CT scanned for planning. Treatment plans were generated using four techniques with two different grid sizes (1 Multiplication-Sign 1 and 2.5 Multiplication-Sign 2.5 mm{sup 2}) to provide optimum dose distribution. Films were placed at different depths and exposed with the selected techniques. A calibration curve for dose versus pixel values was also generated on the same day as the phantom measurement was conducted. The DICOM RT image, dose, and plan data were imported to the in-house software. On axial plane of CT slices, curves were drawn at the position where EBT2 films were placed, and the dose profiles on the lines were acquired. The calculated and measured dose profiles were separated by check points which were marked on the films before irradiation. The segments of calculated profiles were stretched to match their resolutions to that of film dosimetry. Results: On review of treatment plans, the distance between skin and 95% prescribed dose was up to 8 mm for plans of 27 patients. The film measurement revealed that the medial region of phantom surface received a mere 45%-50% of prescribed dose. For wedges, FF, and eComp techniques, region around the nipple received approximately 80% of prescribed dose, although only IMRT showed inhomogeneous dose profile. At deeper depths mainly (6-11 mm depths), film dosimetry showed good agreement with the TPS calculation. In contrast, the measured dose at a 3-mm depth was higher than TPS calculation by 15%-30% for all techniques. For the tangential and IMRT techniques, 1 Multiplication-Sign 1 mm{sup 2} grid size showed a smaller difference than that with a 2.5 Multiplication-Sign 2.5 mm{sup 2} grid size compared to the measurements. Conclusions: In general, TPS even with advanced algorithms do not provide accurate dosimetry in the buildup region, as verified by EBT2 film for all treatment techniques. For all cases, TPS and measured doses were in agreement from 6 mm in depth but differed at shallower depths. Grid size plays an important role in dose calculation. For accurate dosimetry small grid size should be used where differences are lower between TPS and measurements.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 58: Dosimetric validation of electronic compensation for radiotherapy treatment planning

In this study we investigate the deliverability of dosimetric plans generated by the irregular surface compensator (ISCOMP) algorithm for 6 MV photon beams in Eclipse (Varian Medical System, CA). In contrast to physical tissue compensation, the electronic ISCOMP uses MLCs to dynamically modulate the fluence of a photon beam in order to deliver a uniform dose at a user defined plane in tissue. This method can be used to shield critical organs that are located within the treatment portal or improve dose uniformity by tissue compensation in inhomogeneous regions. Three site specific plans and a set of test fields were evaluated using the γ-metric of 3%/ 3 mm on Varian EPID, MapCHECK, and Gafchromic EBT3 film with a clinical tolerance of >95% passing rates. Point dose measurements with an NRCC calibrated ionization chamber were also performed to verify the absolute dose delivered. In all cases the MapCHECK measured plans met the gamma criteria. The mean passing rate for the six EBT3 film field measurements was 96.2%, with only two fields at 93.4 and 94.0% passing rates. The EPID plans passed for fields encompassing the central ∼10 × 10 cm{sup 2} region of the detector; however for larger fields and greater off-axis distances discrepancies were observed and attributed to the profile corrections and modeling of backscatter in the portal dose calculation. The magnitude of the average percentage difference for 21 ion chamber point dose measurements and 17 different fields was 1.4 ± 0.9%, and the maximum percentage difference was −3.3%. These measurements qualify the algorithm for routine clinical use subject to the same pre-treatment patient specific QA as IMRT.

60 APPLIED LIFE SCIENCES↗

Viscous control of cellular respiration by membrane lipid composition

Lipid composition determines the physical properties of biological membranes and can vary substantially between and within organisms. We describe a specific role for the viscosity of energy-transducing membranes in cellular respiration. Engineering of fatty acid biosynthesis in Escherichia coli allowed us to titrate inner membrane viscosity across a 10-fold range by controlling the abundance of unsaturated or branched lipids. These fluidizing lipids tightly controlled respiratory metabolism, an effect that can be explained with a quantitative model of the electron transport chain (ETC) that features diffusion-coupled reactions between enzymes and electron carriers (quinones). Lipid unsaturation also modulated mitochondrial respiration in engineered budding yeast strains. Thus, diffusion in the ETC may serve as an evolutionary constraint for lipid composition in respiratory membranes.

59 BASIC BIOLOGICAL SCIENCES↗

Investigations of nonlinear polarization transfer between obliquely intersecting beams

Electromagnetic waves propagating through plasma can interact nonlinearly through a variety of different mechanisms. The excitation of a plasma beat wave (ions or electrons) can create a refractive index modulation that changes the dispersion of the interacting beams. Alternatively, high-intensity beams can enter the regime where relativistic nonlinearities influence the propagation dynamics. In recent studies [ Opt. Express 29 , 1162 ( 2021 ) OPEXFF 1094-4087 10.1364/OE.413064 ], it was proposed that two beams propagating along the same axis can exchange their polarization state due to nonlinear interaction. Here we present a numerical analysis of two laser beams intersecting in a nonlinear medium at varying angles. Polarization transfer is observed as predicted by analytical theory for a range of angles. For small angles, it is found that filamentation of the interacting beams becomes important. Analytical estimates of the filamentation threshold are presented, and good agreement is found with the simulation data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiscale thermal properties prediction in the Multiphysics Object Oriented Simulation Environment (MOOSE) via a general Boltzmann solver [Poster]

The project objectives were: (1) Engineering-scale fuel performance modeling relies on accurate thermal properties; (2) Thermal properties are inherently multi-scale, arising from atomistic processes and interactions with a material’s microstructure; (3) Heat transport in solids via conduction occurs through transport and scattering of electrons and phonons; (4) Use the Boltzmann transport equation (BTE) to predict the macroscopic behavior of a materials system in terms of the microscopic dynamics of its heat carriers; and (5) This project establishes a new MOOSE (Multiphysics Object Oriented Simulation Environment) module, Boltzmann, dedicated to phonon and thermal electron transport.

36 MATERIALS SCIENCE↗

Breadboard development of a fluid infusion system

A functional breadboard of a zero gravity Intravenous Infusion System (IVI) is presented. Major components described are: (1) infusate pack pressurizers; (2) pump module; (3) infusion set; and (4) electronic control package. The IVI breadboard was designed to demonstrate the feasibility of using the parallel solenoid pump and spring powered infusate source pressurizers for the emergency infusion of various liquids in a zero gravity environment. The IVI was tested for flow rate and sensitivity to back pressure at the needle. Results are presented.

Thompson, R. W.↗

Investigation of system integration methods for bubble domain flight recorders

System integration methods for bubble domain flight records are investigated. Bubble memory module packaging and assembly, the control electronics design and construction, field coils, and permanent magnet bias structure design are studied. A small 60-k bit engineering model was built and tested to demonstrate the feasibility of the bubble recorder. Based on the various studies performed, a projection is made on a 50,000,000-bit prototype recorder. It is estimated that the recorder will occupy 190 cubic in., weigh 12 lb, and consume 12 w power when all of its four tracks are operated in parallel at 150 kHz data rate.

Chen, T. T.↗

Electronic recording of holograms with applications to holographic displays

The paper describes an electronic heterodyne recording which uses electrooptic modulation to introduce a sinusoidal phase shift between the object and reference wave. The resulting temporally modulated holographic interference pattern is scanned by a commercial image dissector camera, and the rejection of the self-interference terms is accomplished by heterodyne detection at the camera output. The electrical signal representing this processed hologram can then be used to modify the properties of a liquid crystal light valve or a similar device. Such display devices transform the displayed interference pattern into a phase modulated wave front rendering a three-dimensional image.

Claspy, P. C.↗

Calibrating for Ionospheric Phase Delays

Technique determines ionospheric phase delay on real-time universally applicable basis in terms of electrons per meter squared by coherently modulating two L-band carrier frequencies received from two Global Positioning System satelites. Two pseudorandom number sequences cross-correlated to derive delay time.

Macdoran, P. F.↗

Experimental observation of ion-acoustic double layers in laboratory plasma

Experimental results on the observation of ion-acoustic double layers in laboratory plasma are presented. In a double-plasma device, modified suitably to inject an electron beam into the target plasma, modulation of the beam through a step potential leads to excitation of ion-acoustic fluctuations. The fluctuations, growing away from the separating grids, develop into weak asymmetric ion-acoustic double layers. The observations are compared with the scenario emerging out of the computer simulations and analytical results on ion-acoustic double layers.

Saxena, Y. C.↗

Strain Sensitivity in Single Walled Carbon Nanotubes for Multifunctional Materials

Single walled carbon nanotubes represent the future of structural aerospace vehicle systems due to their unparalleled strength characteristics and demonstrated multifunctionality. This multifunctionality rises from the CNT's unique capabilities for both metallic and semiconducting electron transport, electron spin polarizability, and band gap modulation under strain. By incorporating the use of electric field alignment and various lithography techniques, a single wall carbon nanotube (SWNT) test bed for measurement of conductivity/strain relationships has been developed. Nanotubes are deposited at specified locations through dielectrophoresis. The circuit is designed such that the central, current carrying section of the nanotube is exposed to enable atomic force microscopy and manipulation in situ while the transport properties of the junction are monitored. By applying this methodology to sensor development a flexible single wall carbon nanotube (SWNT) based strain sensitive device has been developed. Studies of tensile testing of the flexible SWNT device vs conductivity are also presented, demonstrating the feasibility of using single walled HiPCO (high-pressure carbon monoxide) carbon nanotubes as strain sensing agents in a multi-functional materials system.

Heath, D. M.↗