Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Transmission-electron diffraction by MeV electron pulses

We have developed a compact ultrafast electron diffractometer, consisting of a laser-driven rf photocathode that generates 3.0 MeV probe electron pulses, three-stage lens optics, and a custom-built detector for relativistic electrons. High-quality single-shot transmission electron diffraction has been detected from 180-nm-thick Si single crystals, with an excellent special resolution for diffracted beams; the spot width of 0.02 A{sup -1} is obtained. The pulse width is estimated to be 100 fs in duration. Characteristics of the electron beam and other diffractometer features are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New determination of the N-{Delta}(1232) axial form factors from weak pion production and coherent pion production off nuclei at T2K and MiniBooNE energies revisited

We re-evaluate our model predictions in Phys. Rev. D 79, 013002 (2009) for different observables in neutrino induced coherent pion production. This comes as a result of the new improved fit to old bubble chamber data of the dominant axial C{sub 5}{sup A} nucleon-to-Delta form factor. We find an increase of 20%{approx}30% in the values for the total cross sections. Uncertainties induced by the errors in the determination of C{sub 5}{sup A} are computed. Our new results turn out to be compatible within about 1{sigma} with the former ones. We also stress the existing tension between the recent experimental determination of the {sigma}(CCcoh{pi}{sup +})/{sigma}(NCcoh{pi}{sup 0}) ratio by the SciBooNE Collaboration and the theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Emission Analysis of RE{sup 3+} (= Nd{sup 3+} and Er{sup 3+}) Doped Bi{sub 2}O{sub 3}-B{sub 2}O{sub 3}-LiF Glass Systems

This paper reports on the absorption and emission spectra o of RE{sup 3+} (= Nd{sup 3+} or Er{sup 3+}) doped Bi{sub 2}O{sub 3}-B{sub 2}O{sub 3}-LiF (Bi-B-LiF) glass system. The absorption spectrum of Nd{sup 3+} doped Bi-B-LiF glass has exhibited eight absorption bands at 513 nm, 525 nm, 584 nm, 626 nm, 682 nm, 748 nm, 805 nm and 876 which correspond to the electronic transitions of ({sup 4}I{sub 9/2}{yields}{sup 4}G{sub 9/2}), ({sup 4}I{sub 9/2}{yields}{sup 4}G{sub 9/2}, {sup 4}G{sub 7/2}), ({sup 4}I{sub 9/2}{yields}{sup 4}G{sub 5/2}, {sup 2}G{sub 7/2}), ({sup 4}I{sub 9/2}{yields}{sup 2}H{sub 11/2}), ({sup 4}I{sub 9/2}{yields}{sup 4}F{sub 9/2}), ({sup 4}I{sub 9/2}{yields}{sup 4}F{sub 5/2}, {sup 4}S{sub 3/2}), ({sup 4}I{sub 9/2}{yields}{sup 4}F{sub 5/2}, {sup 2}H{sub 9/2}) and ({sup 4}I{sub 9/2}{yields}{sup 4}F{sub 5/2}) respectively. From Nd{sup 3+} : Bi-B-LiF glass, three NIR emission bands have been observed at 900 nm, 1075 nm and 1342 nm, which are assigned to the transitions of ({sup 4}F{sub 3/2}{yields}{sup 4}I{sub 9/2}), ({sup 4}F{sub 3/2}{yields}{sup 4}I{sub 11/2}) and ({sup 4}F{sub 3/2}{yields}{sup 4}I{sub 13/2}) respectively with an excitation at 514.5 nm (Ar{sup +} ion laser). The Er{sup 3+} : Bi-B-LiF glass has revealed six absorption bands at 489 nm, 522 nm, 653 nm, 800 nm, 973 nm and 1531 nm which are labeled to the transitions of ({sup 4}I{sub 15/2}{yields}{sup 4}F{sub 7/2}), ({sup 4}I{sub 15/2}{yields}{sup 2}H{sub 11/2}, 4G{sub 11/2}), ({sup 4}I{sub 15/2}{yields}{sup 4}F{sub 9/2}), ({sup 4}I{sub 15/2}{yields}{sup 4}I{sub 7/2}), ({sup 4}I{sub 15/2}{yields}{sup 4}I{sub 11/2}), and ({sup 4}I{sub 15/2}{yields}{sup 4}I{sub 13/2}) respectively. From the Er{sup 3+}: Bi-B-LiF glass, an NIR emission at 1540 nm ({sup 4}I{sub 13/2}{yields}{sup 4}I{sub 15/2}), has been observed with an excitation at 514.5 nm (Ar{sup +} ion laser).

36 MATERIALS SCIENCE↗

Generation of strong pulsed magnetic fields using a compact, short pulse generator

The generation of strong magnetic fields (∼50 T) using single- or multi-turn coils immersed in water was studied. A pulse generator with stored energy of ∼3.6 kJ, discharge current amplitude of ∼220 kA, and rise time of ∼1.5 μs was used in these experiments. Using the advantage of water that it has a large Verdet constant, the magnetic field was measured using the non-disturbing method of Faraday rotation of a polarized collimated laser beam. This approach does not require the use of magnetic probes, which are sensitive to electromagnetic noise and damaged in each shot. It also avoids the possible formation of plasma by either a flashover along the conductor or gas breakdown inside the coil caused by an induced electric field. In addition, it was shown that this approach can be used successfully to investigate the interesting phenomenon of magnetic field enhanced diffusion into a conductor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recovery of hexagonal Si-IV nanowires from extreme GPa pressure

We use Raman spectroscopy in tandem with transmission electron microscopy and density functional theory simulations to show that extreme (GPa) pressure converts the phase of silicon nanowires from cubic (Si-I) to hexagonal (Si-IV) while preserving the nanowire's cylindrical morphology. In situ Raman scattering of the longitudinal transverse optical (LTO) mode demonstrates the high-pressure Si-I to Si-II phase transition near 9 GPa. Raman signal of the LTO phonon shows a decrease in intensity in the range of 9–14 GPa. Then, at 17 GPa, it is no longer detectable, indicating a second phase change (Si-II to Si-V) in the 14–17 GPa range. Recovery of exotic phases in individual silicon nanowires from diamond anvil cell experiments reaching 17 GPa is also shown. Raman measurements indicate Si-IV as the dominant phase in pressurized nanowires after decompression. Transmission electron microscopy and electron diffraction confirm crystalline Si-IV domains in individual nanowires. Computational electromagnetic simulations suggest that heating from the Raman laser probe is negligible and that near-hydrostatic pressure is the primary driving force for the formation of hexagonal silicon nanowires.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Use of a Mylar filter to eliminate vacuum ultraviolet pulse pileup in low-energy x-ray measurements

We describe a method to reduce vacuum ultraviolet (VUV) pulse pileup (PPU) in x-ray pulse-height Silicon Drift Detector (SDD) signals. An Amptek FAST SDD, with C1 (Si 3 N 4 ) window, measures bremsstrahlung emitted from PFRC-2 plasma to extract the electron temperature (T e ) and density (n e ). The C1 window has low transmissivity for photons with energy below 200 eV though will transmit some VUV and soft x-ray photons, which PFRC-2 plasmas abundantly emit. Multi-VUV-photon PPU contaminates the interpretation of x rays with energy > 100 eV, particularly in a low-energy exponential tail. The predicted low transmissivity of ~1 μm thick Mylar [polyethylene terephthalate (PET)] to photons of energy <100 eV led to the selection of Mylar as the candidate filter to reduce VUV PPU. Experiments were conducted on an x-ray tube with a graphite target and on a quasi-Maxwellian tenuous plasma (n e ~ 10 9 cm –3 ) with effective temperatures reaching 1500 eV. A Mylar filter thickness of 850 nm is consistent with the results. The Mylar-filter-equipped SDD was then used on the PFRC-2 plasma, showing a substantial reduction in the low-energy x-ray signal, supporting our hypothesis of the importance of VUV PPU. Here, we describe the modeling and experiments performed to characterize the effect of the Mylar filter on SDD measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE COMPLETE SPECTRUM OF THE NEUTRON STAR X-RAY BINARY 4U 0614+091

We observed the neutron star (NS) ultra-compact X-ray binary 4U 0614+091 quasi-simultaneously in the radio band (Very Large Array), mid-infrared (IR)/IR (Spitzer/Multiband Imaging Photometer for Spitzer and Infrared Array Camera), near-IR/optical (Small and Moderate Aperture Research Telescope System), optical-UV (Swift/UV-Optical Telescope), soft and hard X-rays (Swift/X-ray Telescope and Rossi-X-ray Timing Explorer). The source was steadily in its 'hard state'. We detected the source in the whole range, for the first time in the radio band at 4.86 and 8.46 GHz and in the mid-IR at 24 {mu}m, up to 100 keV. The optically thick synchrotron spectrum of the jet is consistent with being flat from the radio to the mid-IR band. The flat jet spectrum breaks in the range {approx}(1-4) x 10{sup 13} Hz to an optically thin power-law synchrotron spectrum with spectral index {approx}-0.5. These observations allow us to estimate a lower limit on the jet radiative power of {approx}3 x 10{sup 32} erg s{sup -1} and a total jet power L{sub J} {approx} 10{sup 34}mu{sup -1}{sub 0.05} E {sup 0.53}{sub c} erg s{sup -1} (where E{sub c} is the high-energy cutoff of the synchrotron spectrum in eV and mu{sub 0.05} is the radiative efficiency in units of 0.05). The contemporaneous detection of the optically thin part of the compact jet and the X-ray tail above 30 keV allows us to assess the contribution of the jet to the hard X-ray tail by synchrotron self-Compton (SSC) processes. We conclude that, for realistic jet size, boosting, viewing angle, and energy partition, the SSC emission alone, from the post-shock, accelerated, non-thermal population in the jet, is not a viable mechanism to explain the observed hard X-ray tail of the NS 4U 0614+091.

79 ASTRONOMY AND ASTROPHYSICS↗

A MULTIPHASE SUZAKU STUDY OF X-RAYS FROM {tau} Sco

We obtained relatively high signal-to-noise X-ray spectral data of the early massive star {tau} Sco (B0.2V) with the Suzaku X-ray Imaging Spectrometer (XIS) instrument. This source displays several unusual features that motivated our study: (1) redshifted absorption in UV P Cygni lines to approximately +250 km s{sup -1} suggestive of infalling gas, (2) unusually hard X-ray emission requiring hot plasma at temperatures in excess of 10 MK whereas most massive stars show relatively soft X-rays at a few MK, and (3) a complex photospheric magnetic field of open and closed field lines. In an attempt to understand the hard component better, X-ray data were obtained at six roughly equally spaced phases within the same epoch of {tau} Sco's 41 day rotation period. The XIS instrument has three operable detectors: XIS1 is back-illuminated with sensitivity down to 0.2 keV; XIS0 and XIS2 are front-illuminated with sensitivity only down to 0.4 keV and have an overall less effective area than XIS1. The XIS0 and XIS3 detectors show relatively little variability. In contrast, there is a {approx}4{sigma} detection of a {approx}4% drop in the count rate of the XIS1 detector at one rotational phase. In addition, all three detectors show a {approx}3% increase in count rate at the same phase. The most optimistic prediction of X-ray variability allows for a 40% change in the count rate, particularly near phases where we have pointings. Observed modulations in the X-ray light curve on the rotation cycle is an order of magnitude smaller than this, which places new stringent constraints on future modeling of this interesting magnetic massive star.

79 ASTRONOMY AND ASTROPHYSICS↗

THE SOFT X-RAY AND NARROW-LINE EMISSION OF Mrk 573 ON KILOPARSEC SCALES

We present a study of the circumnuclear region of the nearby Seyfert galaxy Mrk 573 using Chandra, XMM-Newton, and Hubble Space Telescope (HST) data. We have studied the morphology of the soft (<2 keV) X-rays comparing it with the [O III] and H{alpha} HST images. The soft X-ray emission is resolved into a complex extended region. The X-ray morphology shows a biconical region extending up to 12 arcsec (4 kpc) in projection from the nucleus. A strong correlation between the X-rays and the highly ionized gas seen in the [O III]{lambda}5007 A image is reported. Moreover, we have studied the line intensities detected with the XMM-Newton Reflection Grating Spectrometer (RGS) and used them to fit the low-resolution EPIC/XMM-Newton and ACIS/Chandra spectra. The RGS/XMM-Newton spectrum is dominated by emission lines of C VI, O VII, O VIII, Fe XVII, and Ne IX, among other highly ionized species. A good fit is obtained using these emission lines found in the RGS/XMM-Newton spectrum as a template for Chandra spectra of the nucleus and extended emission, coincident with the cone-like structures seen in the [O III]/H{alpha} map. The photoionization model Cloudy provides a reasonable fit for both the nuclear region and the cone-like structures showing that the dominant excitation mechanism is photoionization. For the nucleus the emission is modeled using two phases: a high ionization [log (U) = 1.23] and a low ionization [log (U) = 0.13]. For the high-ionization phase the transmitted and reflected components are in a 1:2 ratio, whereas for the low ionization the reflected component dominates. For the extended emission, we successfully reproduced the emission with two phases. The first phase shows a higher ionization parameter for the northwest (log (U) = 0.9) than for the southeast cone (log (U) = 0.3). Moreover, this phase is transmission dominated for the southeast cone and reflection dominated for the northwest cone. The second phase shows a low-ionization parameter (log (U) = -3) and is rather uniform for northwest and southeast cones and equally distributed in reflection and transmission components. In addition, we have also derived the optical/infrared spectral energy distribution (SED) of the nucleus from high spatial resolution images of Mrk 573. The nuclear optical/infrared SED of the nucleus has been modeled by a clumpy torus model. The torus bolometric luminosity agrees very well with the active galactic nucleus (AGN) luminosity inferred from the observed hard X-ray spectrum. The optical depth along the line of sight expected from the torus modeling indicates a high neutral hydrogen column density in agreement with the classification of the nucleus of Mrk 573 as a Compton-thick AGN.

79 ASTRONOMY AND ASTROPHYSICS↗

EVIDENCE OF EXPLOSIVE EVAPORATION IN A MICROFLARE OBSERVED BY HINODE/EIS

We present a detailed study of explosive chromospheric evaporation during a microflare which occurred on 2007 December 7 as observed with the Extreme-ultraviolet Imaging Spectrometer on board Hinode. We find temperature-dependent upflows for lines formed from 1.0 to 2.5 MK and downflows for lines formed from 0.05 to 0.63 MK in the impulsive phase of the flare. Both the line intensity and the nonthermal line width appear enhanced in most of the lines and are temporally correlated with the evaporation velocity. Our results are consistent with the numerical simulations of flare models, which take into account a strong nonthermal electron beam in producing the explosive chromospheric evaporation. The explosive evaporation observed in this microflare implies that the same dynamic processes may exist in events with very different magnitudes.

79 ASTRONOMY AND ASTROPHYSICS↗

Observation of inclined EeV air showers with the radio detector of the Pierre Auger Observatory

With the Auger Engineering Radio Array (AERA) of the Pierre Auger Observatory, we have observed the radio emission from 561 extensive air showers with zenith angles between 60o and 84o. In contrast to air showers with more vertical incidence, these inclined air showers illuminate large ground areas of several km2 with radio signals detectable in the 30 to 80 MHz band. A comparison of the measured radio-signal amplitudes with Monte Carlo simulations of a subset of 50 events for which we reconstruct the energy using the Auger surface detector shows agreement within the uncertainties of the current analysis. As expected for forward-beamed radio emission undergoing no significant absorption or scattering in the atmosphere, the area illuminated by radio signals grows with the zenith angle of the air shower. Inclined air showers with EeV energies are thus measurable with sparse radio-antenna arrays with grid sizes of a km or more. This is particularly attractive as radio detection provides direct access to the energy in the electromagnetic cascade of an air shower, which in case of inclined air showers is not accessible by arrays of particle detectors on the ground.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Double side read-out technique for mitigation of radiation damage effects in PbWO 4 crystals

Test beam results of a calorimetric module based on 3×3×22 cm 3 PbWO 4 crystals, identical to those used in the CMS ECAL Endcaps, read out by a pair of photodetectors coupled to the two opposite sides (front and rear) of each crystal are presented. Nine crystals with different level of induced absorption, from 0 to 20 m -1 , have been tested using electrons in the 50–200 GeV energy range. Photomultiplier tubes have been chosen as photodetectors to allow for a precise measurement of highly damaged crystals. The information provided by this double side read-out configuration allows to correct for event-by-event fluctuations of the longitudinal development of electromagnetic showers. By strongly mitigating the effect of non-uniform light collection efficiency induced by radiation damage, the double side read-out technique significantly improves the energy resolution with respect to a single side read-out configuration. The non-linearity of the response arising in damaged crystals is also corrected by a double side read-out configuration and the response linearity of irradiated crystals is restored. In high radiation environments at future colliders, as it will be the case for detectors operating during the High Luminosity phase of the Large Hadron Collider, defects can be created inside the scintillator volume leading to a non-uniform response of the calorimetric cell. As a result, the double side read-out technique presented in this study provides a valuable way to improve the performance of calorimeters based on scintillators whose active volumes are characterized by high aspect ratio cells similar to those used in this study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cerium-doped scintillating fused-silica fibers

In this work, we report on a set of measurements made on (scintillating) cerium-doped fused-silica fibers using high-energy particle beams. These fibers were uniformly embedded in a copper absorber in order to utilize electromagnetic showers as a source of charged particles for generating signals. This new type of cerium-doped fiber potentially offers myriad new applications in calorimeters in high-energy physics, tracking systems, and beam monitoring detectors for future applications. The light yield, pulse shape, attenuation length, and light propagation speeds are given and discussed. Possible future applications are also explored.

47 OTHER INSTRUMENTATION↗

Optimization of quantum interferometric metrological sensors in the presence of photon loss

We optimize two-mode entangled number states of light in the presence of loss in order to maximize the extraction of the available phase information in an interferometer. Our approach optimizes over the entire available input Hilbert space with no constraints, other than fixed total initial photon number. We optimize to maximize the Fisher information, which is equivalent to minimizing the phase uncertainty. We find that in the limit of zero loss, the optimal state is the maximally path-entangled (so-called N00N) state, for small loss, the optimal state gradually deviates from the N00N state, and in the limit of large loss, the optimal state converges to a generalized two-mode coherent state, with a finite total number of photons. The results provide a general protocol for optimizing the performance of a quantum optical interferometer in the presence of photon loss, with applications to quantum imaging, metrology, sensing, and information processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamical Casimir effect in superconducting microwave circuits

We theoretically investigate the dynamical Casimir effect (DCE) in electrical circuits based on superconducting microfabricated waveguides with tunable boundary conditions. We propose implementing a rapid modulation of the boundary conditions by tuning the applied magnetic flux through superconducting quantum-interference devices that are embedded in the waveguide circuits. We consider two circuits: (i) An open waveguide circuit that corresponds to a single mirror in free space, and (ii) a resonator coupled to a microfabricated waveguide, which corresponds to a single-sided cavity in free space. We analyze the properties of the DCE in these two setups by calculating the generated photon-flux densities, output-field correlation functions, and the quadrature squeezing spectra. We show that these properties of the output field exhibit signatures unique to the radiation due to the DCE, and could, therefore, be used for distinguishing the DCE from other types of radiation in these circuits. We also discuss the similarities and differences between the DCE, in the resonator setup, and the down-conversion of pump photons in parametric oscillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Medium propagation effects in high-order harmonic generation of Ar and N{sub 2}

We report theoretical calculations of high-order harmonic generation (HHG) by intense infrared lasers in atomic and molecular targets taking into account the macroscopic propagation of both fundamental and harmonic fields. On the examples of Ar and N{sub 2}, we demonstrate that these ab initio calculations are capable of accurately reproducing available experimental results with isotropic and aligned target media. We further present detailed analysis of HHG intensity and phase under various experimental conditions, in particular, as the wavelength of the driving laser changes. Most importantly, our results strongly support the factorization of HHG at the macroscopic level into a product of a returning electron wave packet and the photorecombination transition dipole under typical experimental conditions. This implies that the single-atom or single-molecule structure information can be retrieved from experimentally measured HHG spectra.

74 ATOMIC AND MOLECULAR PHYSICS↗

Role of pump coherence in two-photon interferometry

We use a parametric down-conversion source pumped by a short-coherence-length continuous-wave (CW) diode laser to perform two-photon interferometry in an intermediate regime between the more familiar Franson-type experiments with a long-coherence-length pump laser, and the short pulsed pump ''time-bin'' experiments pioneered by Gisin's group. The use of a time-bin-like Mach-Zehnder interferometer in the CW pumping beam induces coherence between certain two-photon amplitudes, while the CW nature of the experiment prevents the elimination of remaining incoherent ones. The experimental results highlight the role of pump coherence in two-photon interferometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent transients mimicked by two-photon coherent control of a three-level system

We show theoretically and experimentally that two-photon coherent control in a V-shape three-level system projects a one-photon coherent transient in a simple two-level system. The second- and third-order spectral phase terms of a shaped laser pulse play the roles of time and quadratic spectral phase, respectively, in conventional coherent transients. In a three-pulse coherent control experiment of atomic rubidium, the phase and amplitude of controlled transition probability is retrieved from a two-dimensional Fourier-transform spectral peak. It is hoped that this control scheme may harness coherent control capability on multidimensional Fourier-transform spectroscopy.

74 ATOMIC AND MOLECULAR PHYSICS↗