Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

X-ray and gamma ray astronomy detectors

X-ray and gamma ray astronomy was made possible by the advent of space flight. Discovery and early observations of celestial x-rays and gamma rays, dating back almost 40 years, were first done with high altitude rockets, followed by Earth-orbiting satellites> once it became possible to carry detectors above the Earth's atmosphere, a new view of the universe in the high-energy part of the electromagnetic spectrum evolved. Many of the detector concepts used for x-ray and gamma ray astronomy were derived from radiation measuring instruments used in atomic physics, nuclear physics, and other fields. However, these instruments, when used in x-ray and gamma ray astronomy, have to meet unique and demanding requirements related to their operation in space and the need to detect and measure extremely weak radiation fluxes from celestial x-ray and gamma ray sources. Their design for x-ray and gamma ray astronomy has, therefore, become a rather specialized and rapidly advancing field in which improved sensitivity, higher energy and spatial resolution, wider spectral coverage, and enhanced imaging capabilities are all sought. This text is intended as an introduction to x-ray and gamma ray astronomy instruments. It provides an overview of detector design and technology and is aimed at scientists, engineers, and technical personnel and managers associated with this field. The discussion is limited to basic principles and design concepts and provides examples of applications in past, present, and future space flight missions.

Decher, Rudolf↗

The Neutron Star Interior Composition Explorer

The Neutron star Interior Composition Explorer (NICE) will be a Mission of Opportunity dedicated to the study of neutron stars, the only places in the universe where all four fundamental forces of nature are simultaneously in play. NICE will explore the exotic states of matter within neutron stars, revealing their interior and surface compositions through rotation resolved X-ray spectroscopy. Absolute time-referenced data will allow NICE to probe the extreme physical environments associated with neutron stars, leveraging observations across the electromagnetic spectrum to answer decades-old questions about one of the most powerful cosmic accelerators known. Finally, NICE will definitively measure stabilities of pulsars as clocks, with implications for navigation, a pulsar-based timescale, and gravitational-wave detection. NICE will fly on the International Space Station, while GLAST is on orbit and post-RXTE, and will allow for the discovery of new high-energy pulsars and provide continuity in X-ray timing astrophysics.

Gendreau, Keith C.↗

CubeSat Measures World's First Ice Cloud Map to Support Climate Research

Virginia Diodes, Inc. received NASA SBIR Awards to fund research and development for a lesser developed region of the electromagnetic spectrum—terahertz waves. Their work led to funding from NASA ESTO, and the resulting CubeSat (named IceCube) captured the world’s first ice cloud map, which will contribute to our understanding of Earth’s climate

Light, Bailey↗

Optical Follow-Up of the Neutron Star-Black Hole Mergers S200105ae and S200115j

LIGO and Virgo’s third observing run revealed the first neutron star–black hole (NSBH) merger candidates in gravitational waves. These events are predicted to synthesize r-process elements creating optical/near-infrared ‘kilonova’ emission. The joint gravitational wave and electromagnetic detection of an NSBH merger could be used to constrain the equation of state of dense nuclear matter, and independently measure the local expansion rate of the Universe. Here, we present the optical follow-up and analysis of two of the only three high-significance NSBH merger candidates detected to date, S200105ae and S200115j, with the Zwicky Transient Facility. The Zwicky Transient Facility observed ~48% of S200105ae and ~22% of S200115j’s localization probabilities, with observations sensitive to kilonovae brighter than −17.5 mag fading at 0.5 mag d−1 in the g- and r-bands; extensive searches and systematic follow-up of candidates did not yield a viable counterpart. We present state-of-the-art kilonova models tailored to NSBH systems that place constraints on the ejecta properties of these NSBH mergers. We show that with observed depths of apparent magnitude ~22 mag, attainable in metre-class, wide-field-of-view survey instruments, strong constraints on ejecta mass are possible, with the potential to rule out low mass ratios, high black hole spins and large neutron star radii.

Shreya Anand↗

Using Pulsars For Clock Steering and Time Transfer

As we prepare for extended missions on the Moon and in cislunar space, precise time synchronization between lunar and terrestrial clocks becomes increasingly critical for navigation, communication, and science measurements. One promising technique is the use of millisecond pulsars, which are highly magnetized, rapidly rotating neutron stars emitting beams of electromagnetic radiation. These celestial clocks offer extraordinary stability and precision, with rotational periods ranging from about 1 to 10 milliseconds and timing stability comparable to laboratory atomic clocks on Earth. Pulsars can provide a common time reference for clock comparisons, allowing time transfer independent of a communications link.

Spacecraft Communications, Command and Tracking↗

Effective Field Theory Analysis and Active Neutron Veto Design for the Cryogenic Dark Matter Search

Astrophysical measurements and cosmological predictions suggest the exists of a large amount of matter in the universe that does not interact via electromagnetic forces. This non-luminescent matter, known dark matter, exists in halos that encompass and are within galaxies, including the Milky Way. Therefore, dark matter particles should should be directly detectable by experiments on Earth, such as the Super Cryogenic Dark Matter Search (SuperCDMS). Dark matter is assumed to be low mass (< 100 GeV/c2) and interact via the weak force using either a spin-independent or spin-dependent coupling. However, making incorrect assumptions about dark matter interactions can lead to misleading results. Because interactions with dark matter particles are rare, direct detection experiments must be able to shield for or reject backgrounds to very low levels. Low energy neutron backgrounds that make it to the detectors are especially dangerous, because they cannot be easily distinguished from the expected dark matter signal. Scintillator doped with a high neutron-capture cross-section material can be used to detect neutrons via their resulting gamma rays. Examples of such detectors using liquid scintillator have been successfully used in past high-energy physics (HEP) experiments. However, a liquid scintillator can leak and is not as amenable to modular or complex shapes as a solid scintillator. The light outputs and efficiencies of gadolinium-loaded polystyrene-based scintillators have been explored using a wide variety of gadolinium compounds with varying concentrations. Collection strategies using a wavelength shift- ing (WLS) fiber and silicon photomultipliers (SiPMs) were also evaluated as a possible neutron veto for an upgrade to SuperCDMS SNOLAB. The scattering of dark matter particles off nuclei in direct detection experiments can be described in terms of a multidimensional effective field theory (EFT). A new systematic analysis technique is developed using the EFT approach and Bayesian inference methods to exploit, when possible, the energy-dependent information of the detected events, experimental efficiencies, and backgrounds. Highly dimensional likelihoods are calculated over the mass of the weakly interacting massive particle (WIMP) and multiple EFT coupling coefficients, which can then be used to set limits on these parameters and choose models (EFT operators) that best fit the direct detection data. Expanding the parameter space beyond the standard spin-independent isoscalar cross section and WIMP mass reduces tensions between previously published experiments. Combining these experiments to form a single joint likelihood leads to stronger limits than when each experiment is considered on its own. Simulations using two nonstandard operators (O3 and O8) are used to test the proposed analysis technique in up to five dimensions and demonstrate the importance of using multiple likelihood projections when determining constraints on WIMP mass and EFT coupling coefficients. In particular, this shows that an explicit momentum dependence in dark matter scattering can be identified. CDMSlite Run 2 was a search for Weakly Interacting Massive Particles (WIMPs) with a cryogenic 600 g Germanium detector operated deep underground. It was operated in a mode optimizing sensitivity to WIMPs of relatively low mass, 2 - 20 GeV, while sacrificing background rejection. An EFT analysis of CDMSlite Run 2 data from SuperCDMS Soudan is presented here. A binned likelihood Bayesian analysis was performed on the data, optimizing over the parameters of EFT interactions and the recoil energy spectra due to the dominant Compton scattering and tritium backgrounds. Recoil energy regions within 5σ of known activation peaks were removed from the analysis. The Bayesian evidences of the resulting likelihoods show that CDMSlite Run 2 data is entirely consistent with the background models with no EFT interaction necessary. Upper limits on the WIMP mass and coupling coefficients amplitudes and phases are presented for each EFT operator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulsed electromagnetic gas acceleration

Experimental data were combined with one-dimensional conservation relations to yield information on the energy deposition ratio in a parallel-plate accelerator, where the downstream flow was confined to a constant area channel. Approximately 70% of the total input power was detected in the exhaust flow, of which only about 20% appeared as directed kinetic energy, thus implying that a downstream expansion to convert chamber enthalpy into kinetic energy must be an important aspect of conventional high power MPD arcs. Spectroscopic experiments on a quasi-steady MPD argon accelerator verified the presence of A(III) and the absence of A(I), and indicated an azimuthal structure in the jet related to the mass injection locations. Measurements of pressure in the arc chamber and impact pressure in the exhaust jet using a piezocrystal backed by a Plexiglas rod were in good agreement with the electromagnetic thrust model.

Jahn, R. G.↗

Thermophysical Properties Measurements of Zr62Cu20Al10Ni8

Thermophysical property studies performed at high temperature can prove challenging because of reactivity problems brought on by the elevated temperatures. Contaminants from measuring devices and container walls can cause changes in properties. To prevent this, containerless processing techniques can be employed to isolate a sample during study. A common method used for this is levitation. Typical levitation methods used for containerless processing are, aerodynamically, electromagnetically and electrostatically based. All levitation methods reduce heterogeneous nucleation sites, 'which in turn provide access to metastable undercooled phases. In particular, electrostatic levitation is appealing because sample motion and stirring are minimized; and by combining it with optically based non-contact measuring techniques, many thermophysical properties can be measured. Applying some of these techniques, surface tension, viscosity and density have been measured for the glass forming alloy Zr62Cu20Al10Ni8 and will be presented with a brief overview of the non-contact measuring method used.

Bradshaw, Richard C.↗

Coherent phonon spectroscopy of non-fully symmetric modes using resonant terahertz excitation

We use intense terahertz (THz) frequency electromagnetic pulses generated via optical rectification in an organic crystal to drive vibrational lattice modes in single crystal Tellurium. The coherent modes are detected by measuring the polarization changes of femtosecond laser pulses reflecting from the sample surface, resulting in a phase-resolved detection of the coherent lattice motion. We compare the data to a model of Lorentz oscillators driven by the near-single-cycle broadband THz pulse. The demonstrated technique of optically probed coherent phonon spectroscopy with THz frequency excitation could prove to be a viable alternative to other time-resolved spectroscopic methods like standard THz time domain spectroscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamics of ionisation and entanglement in the 'atom + quantum electromagnetic field' system

The dynamics of a model Rydberg atom in a strong nonclassical electromagnetic field is investigated. The field-induced transitions to the continuum involving different numbers of photons (with intermediate states in the discrete spectrum) are taken into account and the specific features of ionisation in 'squeezed' field states are considered in comparison with the case of classical light. A significant decrease in the ionisation rate is found, which is caused by the interference stabilisation of the atomic system. The entanglement of the atomic and field subsystems, the temporal dynamics of the correlations found, and the possibility of measuring them are analysed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Lagrangian statistics in weakly forced two-dimensional turbulence

Measurements of Lagrangian single-point and multiple-point statistics in a quasi-two-dimensional stratified layer system are reported. The system consists of a layer of salt water over an immiscible layer of Fluorinert and is forced electromagnetically so that mean-squared vorticity is injected at a well-defined spatial scale r i . Simultaneous cascades develop in which enstrophy flows predominately to small scales whereas energy cascades, on average, to larger scales. Lagrangian correlations and one- and two-point displacements are measured for random initial conditions and for initial positions within topological centers and saddles. Some of the behavior of these quantities can be understood in terms of the trapping characteristics of long-lived centers, the slow motion near strong saddles, and the rapid fluctuations outside of either centers or saddles. We also present statistics of Lagrangian velocity fluctuations using energy spectra in frequency space and structure functions in real space. We compare with complementary Eulerian velocity statistics. We find that simultaneous inverse energy and enstrophy ranges present in spectra are not directly echoed in real-space moments of velocity difference. Nevertheless, the spectral ranges line up well with features of moment ratios, indicating that although the moments are not exhibiting unambiguous scaling, the behavior of the probability distribution functions is changing over short ranges of length scales. Furthermore, implications for understanding weakly forced 2D turbulence with simultaneous inverse and direct cascades are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Estimation of Snow Mass Information via Assimilation of C-Band Synthetic Aperture Radar Backscatter Observations Into an Advanced and Surface Model

This study assimilated Sentinel-1 C-band backscatter observations over snow-covered terrain into the Noah-Multiparameterization land surface model using support vector machine (SVM) regression and an ensemble Kalman filter to improve the modeled terrestrial snow mass estimates. The data assimilation (DA) experiment was conducted across Western Colorado from September 2016 to August 2017. As part of the DA experiments, the impact of a rule-based update was evaluated by comparing snow water equivalent (SWE) estimates via DA (with [ DAv1 ] and without [ DAv2 ] the rule-based update) against SNOTEL SWE measurements. Results confirmed that rule-based update helped minimize SVM controllability issues, and in turn, improved the accuracy of SWE estimates relative to both open loop (OL) and DAv2 . Comparison of SWE estimates from Sentinel-1 DAv1 against SNOTEL SWE revealed that 75% of stations showed improvements in bias and correlation coefficient relative to the OL. Assimilated SWE estimates also showed statistical improvements during both the snow accumulation and snow ablation periods. However, unbiased root mean square error showed a slight increase during the snow ablation period due to the large variability in the electromagnetic response of C-band backscatter over deep and/or wet snow. Improvement of the SWE estimates also resulted in improving river discharge estimates compared to in situ measurements. River discharge using Sentinel-1 DAv1 improved the Nash–Sutcliffe efficiency at all available stations. These results suggest that physically constrained SVM can serve as an efficient observation operator for snow mass DA through explicit consideration of the first-order C-band scattering mechanisms over different terrestrial snow conditions.

Jongmin Park↗

TH-AB-202-10: Quantifying the Accuracy and Precision of Six Degree-Of-Freedom Motion Estimation for Use in Real-Time Tumor Motion Monitoring During Radiotherapy

Purpose: Kilovoltage intrafraction monitoring (KIM) scheme has been successfully used to simultaneously monitor 3D tumor motion during radiotherapy. Recently, an iterative closest point (ICP) algorithm was implemented in KIM to also measure rotations about three axes, enabling real-time tracking of tumor motion in six degrees-of-freedom (DoF). This study aims to evaluate the accuracy of the six DoF motion estimates of KIM by comparing it with the corresponding motion (i) measured by the Calypso; and (ii) derived from kV/MV triangulation. Methods: (i) Various motions (static and dynamic) were applied to a CIRS phantom with three embedded electromagnetic transponders (Calypso Medical) using a 5D motion platform (HexaMotion) and a rotating treatment couch while both KIM and Calypso were used to concurrently track the phantom motion in six DoF. (ii) KIM was also used to retrospectively estimate six DoF motion from continuous sets of kV projections of a prostate, implanted with three gold fiducial markers (2 patients with 80 fractions in total), acquired during the treatment. Corresponding motion was obtained from kV/MV triangulation using a closed form least squares method based on three markers’ positions. Only the frames where all three markers were present were used in the analysis. The mean differences between the corresponding motion estimates were calculated for each DoF. Results: Experimental results showed that the mean of absolute differences in six DoF phantom motion measured by Calypso and KIM were within 1.1° and 0.7 mm. kV/MV triangulation derived six DoF prostate tumor better agreed with KIM estimated motion with the mean (s.d.) difference of up to 0.2° (1.36°) and 0.2 (0.25) mm for rotation and translation, respectively. Conclusion: These results suggest that KIM can provide an accurate six DoF intrafraction tumor during radiotherapy.

60 APPLIED LIFE SCIENCES↗

Comparison of the Experimental Performance of Ferroelectric CPW Circuits with Method of Moment Simulations and Conformal Mapping

Experimental measurements of coplanar waveguide (CPW) circuits atop thin films of ferroelectric Ba(x)Sr(1-x)TiO3 (BST) were made as a function bias from 0 to 200 V and frequency from 0.045 to 20 GHz. The resulting phase shifts are compared with method of moments electromagnetic simulations and a conformal mapping analysis to determine the dielectric constant of the BST films. Based on the correlation between the experimental and the modeled data, an analysis of the extent to which the electromagnetic simulators provide reliable values for the dielectric constant of the ferroelectric in these structures has been performed. In addition, to determine how well the modeled data compare with experimental data, the dielectric constant values were also compared to low frequency measurements of interdigitated capacitor circuits on the same films. Results of these comparisons will be presented.

VanKeuls, Fred W.↗

Measurements of energy distribution in microwave plasmas of N2 and He and comparisons with results for H2

An electrothermal propulsion concept utilizing a microwave plasma system as the mechanism to convert electromagnetic energy into translational energy of the flowing gas is being investigated. Specifically, this study compares the energy transfer characteristics of three different gases, H2, N2, and He, to gain some insight as to the dominant energy transfer processes present in a microwave plasma. A calorimetric experimental system has been designed and built enclosing the microwave plasma system to accurately determine the net energy transferred to the flowing gas. Results are obtained for N2 and He discharges and compared with previously reported experimental results for H2.

Chapman, R.↗

Radio-frequency (RF) electromagnetic emissions from materials under high-frequency mechanical excitation

Direct contact piezoelectric transducers were used to excite compacted polycrystalline dielectric material samples with high amplitude but short duration ultrasound through a frequency range of 50 kHz to 10 MHz, while near field RF emissions were measured in 12 frequency bands from 18 to 750 GHz using a suite of detectors. Emissions were observed only in three detectors, covering the 40-75 GHz, 110-170 GHz, and 170-260 GHz frequency ranges. Emission amplitudes appear to rise nonlinearly with applied ultrasound amplitude, and the emission amplitudes versus ultrasound frequency are different than the thermal responses of these samples. Data comparing thermal responses and electromagnetic emissions versus ultrasound frequency and amplitude for several sample types (oxidizers and energetic materials) are reported.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurements of DC SQUID Damping Effects on Superconducting Resonant Circuits

Here, we present experimental measurements of SQUID-induced damping effects on strongly coupled, lumped-element resonators in the 500kHz–1 MHz frequency range. While dc SQUIDs are commonly used for sensitive readout of electromagnetic signals such as in lumped-element axion dark matter searches, coupling a dc SQUID to a resonant circuit modifies the circuit's resonance frequency, quality factor, noise, and impedance. These parameters have a direct impact on the science reach of axion dark matter detectors, making it important to understand SQUID damping contributions. We describe a helium dip probe and two-stage SQUID readout scheme used to probe SQUID damping effects. Measurements from this setup inform the design and operation of both future test platforms as well as next-generation dark-matter experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗