Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

BICMOS power detector for pulsed Rf power amplifiers

A BiCMOS power detector for pulsed radio-frequency power amplifiers is proposed. Given the pulse waveform and a fraction of the power amplifier's input or output signal, the detector utilizes a low-frequency feedback loop to perform a successive approximation of the amplitude of the input signal. Upon completion of the successive approximation, the detector returns 9-bits representing the amplitude of the RF input signal. Using the pulse waveform from the power amplifier, the detector can dynamically adjust the rate of the binary search operation in order to return the updated amplitude information of the RF input signal at least every 1ms. The detector can handle pulse waveform frequencies from 50kHz to 10MHz with duty cycles in the range of 5- 50% and peak power levels of -10 to 10dBm. The signal amplitude measurement can be converted to a peak power measurement accurate to within ±0.6dB of the input RF power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Long-distance transmission of light in a scintillator-based radiation detector

Scintillator-based radiation detectors capable of transmitting light indicating the presence of radiation for long distances are disclosed herein. A radiation detector can include a scintillator layer and a light-guide layer. The scintillator layer is configured to produce light upon receiving incident radiation. The light-guide layer is configured to receive light produced by the scintillator layer and either propagate the received light through the radiation detector or absorb the received light and emit light, through fluorescence, that is propagated through the radiation detector. A radiation detector can also include an outer layer partially surrounding the scintillator layer and light-guide layer. The index of refraction of the light-guide layer can be greater than the index of refraction of adjacent layers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of a Deep Learning Based Measurement of the Inclusive Muon Neutrino Charged-current Cross Section in the NOvA Near Detector

NOvA is a long-baseline neutrino oscillation experiment. It uses the NuMI beam from Fermilab and two sampling calorimeter detectors placed off-axis from the beam. The 293 ton Near Detector measures the unoscillated neutrino energy spectrum, which can be used to predict the neutrino energy spectrum observed at the 14 kton Far Detector. The Near Detector also provides an excellent opportunity to measure neutrino interaction cross sections with high statistics, which will benefit current and future long-baseline neutrino oscillation experiments. This analysis implements new algorithms to identify $\nu_{\mu}$ charge-current events by using visual deep learning tools such as convolutional neural networks. We present the status of a measurement of the inclusive $\nu_{\mu}$ CC cross section in the NOvA Near Detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Comparative Study of Automated Infrasound Detectors - PMCC and AFD with Analyst Review.

Automated detections calculated by the progressive multi-channel correlation (PMCC) method (Cansi, 1995) and the adaptive F detector (AFD) (Arrowsmith et al., 2009) are compared to the signals identified by five independent analysts. Each detector was applied to a four-hour time sequence recorded by the Korean infrasound array CHNAR. This array was used because it is composed of both small (<100 m) and large (~1000 m) aperture element spacing. The four hour time sequence contained a number of easily identified signals under noise conditions that have average RMS amplitudes varied from 1.2 to 4.5 mPa (1 to 5 Hz), estimated with running five-minute window. The effectiveness of the detectors was estimated for the small aperture, large aperture, small aperture combined with the large aperture, and full array. The full and combined arrays performed the best for AFD under all noise conditions while the large aperture array had the poorest performance for both detectors. PMCC produced similar results as AFD under the lower noise conditions, but did not produce as dramatic an increase in detections using the full and combined arrays. Both automated detectors and the analysts produced a decrease in detections under the higher noise conditions. Comparing the detection probabilities with Estimated Receiver Operating Characteristic (EROC) curves we found that the smaller value of consistency for PMCC and the larger p-value for AFD had the highest detection probability. These parameters produced greater changes in detection probability than estimates of the false alarm rate. The detection probability was impacted the most by noise level, with low noise (average RMS amplitude of 1.7 mPa) having an average detection probability of ~40% and high noise (average RMS amplitude of 2.9 mPa) average detection probability of ~23%.

58 GEOSCIENCES↗

Detector R&D for ANNIE and Future Neutrino Experiments

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is designed to serve as a test bed for new detector technologies in future water and liquid scintillator based neutrino experiments. Located on the Booster Neutrino Beam at Fermilab, ANNIE will be the first gadolinium-loaded water Cherenkov detector on a neutrino beam and will provide high statistics measurements of neutron yields from neutrino interactions in water. It is also the first particle physics application of the new photosensor technology: Large Area Picosecond Photodetectors (LAPPDs). With single photon time resolutions of roughly 50 psec and mm-level imaging capabilities, LAPPDs bring considerable new capabilities for neutrino reconstruction in Cherenkov and scintillator detectors. Leveraging this technology to make detailed neutrino measurements, ANNIE will serve as a first demonstration of their impact on physics. In addition to LAPPDs, the ANNIE R&D program will likely explore other new technologies such as the addition of water-based liquid scintillator. The ANNIE Phase II detector is currently under construction and will start to take data in the summer of 2019. In this talk, I will present on the ANNIE detector R&D program and its relevance to current and future neutrino experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thallium Bromide Semiconductor Radiation Materials and Detectors Characterization Studies

Two overarching requirements of crucial importance for the commercial and scientific establishment of semiconductor radiation detectors are: (1) exceptionally high-purity crystals with impurity concentrations less than 1 part-per-billion and (2) single crystals that are relatively free from subgrain boundaries, secondary phases, dislocations, and other electrically-active defects. We investigated the properties of thallium bromide (TlBr) material that affect its performance with the goal of increasing the material's commercial viability for radiation detection applications. For this purpose, we used beamlines at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory (BNL), performing Micron-scale X-ray Detector Mapping, White Beam X-ray Diffraction Topography, and Micron-scale X-ray Fluorescence. These characterization methods improve the industry's understanding of TlBr and lead to the production of improved instrumentation. In this particular study we report electro-migration measurements of positive-ion Cu, Ag, and Au impurities in TlBr detectors under electric field strengths typically used for device operation. BNL improved TlBr detectors with an electrode design that corrects the response non-uniformities caused by crystal defects. This design can achieve improved energy resolution while using typical-grade, commercial crystals with relaxed quality requirements, thus reducing the overall cost of detectors. Additional characterization will be necessary to fully understand the structure and performance of TlBr with the ultimate goal to achieve the highest energy resolution. Our findings from past work will be presented along with our recommendations for additional investigation.

36 MATERIALS SCIENCE↗

Radiation detectors employing contemporaneous detection and decontamination

Radiation detectors and methods of using the radiation detectors that provide a route for surface decontamination during use are described. The detectors utilize light illumination of an internal surface during use. Light is in the longer UV to near-infrared spectra and desorbs contamination from internal surfaces of radiation detectors. The methods can be carried out while the detectors are in operation, preventing the appearance of the negative effects of radioactive and non-radioactive contamination during a detection regime and following a detection regime.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method and apparatus for evaluating superconducting tunnel junction detector noise versus bias voltage

A technique for characterizing the noise behavior of a superconducting tunnel junction (STJ) detector as a function of its applied bias voltage Vb by stepping the STJ's bias voltage across a predetermined range and, at each applied bias, making multiple measurements of the detector's current, calculating their mean and their standard deviation from their mean, and using this standard deviation as a measure of the STJ detector's noise at that applied bias. Because the method is readily executed under computer control, it is particularly useful when large numbers of STJ detectors require biasing, as in STJ detector arrays In a preferred implementation, the STJ is measured under computer control by attaching it to a digital spectrometer comprising a digital x-ray processor (DXP) coupled to a preamplifier that can set the STJ's bias voltage Vb using a digital-to-analog converter (DAC) controlled by the DXP.

Warburton, William K.↗

A dark matter search using the final CDMS-II data and 100 mm SuperCDMS germanium detector ionization test

Astrophysical observations indicate that approximately 85% of the matter in the universe is nonluminous, nonbaryonic, and nonrelativistic (cold) dark matter. Weakly Interacting Massive Particles (WIMPs) are a particularly well motivated dark matter particle candidate. They would be thermally produced in the early universe and their relics account for the current dark matter abundance. WIMP candidate particles are naturally provided by extensions to the Standard Model of particle physics, such as supersymmetry. The Cryogenic Dark Matter Search (CDMS) experiment operates cryogenic germanium and silicon particle detectors in the low-background environment of the Soudan Underground Laboratory in northern Minnesota to search for WIMP-nucleus scatters while rejecting electron-recoil background. The detectors simultaneously measure the ionization and phonon energies of each scattering event. The difference in ionization yield (ratio of ionization energy to recoil energy) discriminates nuclear recoils from the electron-recoil background efficiently.More sensitive detectors are required to probe the WIMP parameter space with lower WIMP-nucleon scattering cross sections. To support the R&D effort especially the detector R&D and characterization of the SuperCDMS experiment, a new CDMS test facility has been developed on the University of Minnesota campus. This thesis documents the test facility and the work involved in its development. In the test facility, we performed the first ionization collection efficiency measurements of the ionization test devices. The test devices are fabricated with detector-grade germanium crystals that are 100 mm in diameter, which is the largest available, and 33 mm in thickness. The measured efficiencies are consistent with the earlier measurements conducted with smaller Ge crystals, demonstrating that these 100 mm crystals can be used for development of the next generation dark matter detectors.Improvements of data analysis methods can also potentially improve the sensitivity of an experiment. The data taken during the last four runs of CDMS II with total raw exposure 612 kg-day were reprocessed with improved ionization pulse reconstruction algorithm. We present the classic timing analysis with the reprocessed data in this thesis. For the four runs combined, this analysis resulted in a new WIMP-nucleon cross section 4.4×10 -44 cm 2 for a WIMP mass of 70 GeV, which is a factor of 1.6 improvement compared to the original c58 classic timing analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

A Strategy for Low-Mass Dark Matter Searches with Cryogenic Detectors in the SuperCDMS SNOLAB Facility

The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-based scenarios are forecasted to probe many square decades of unexplored dark matter parameter space below 5 GeV, covering over 6 decades in mass: 1-100 eV for dark photons and axion-like particles, 1-100 MeV for dark-photon-coupled light dark matter, and 0.05-5 GeV for nucleon-coupled dark matter. They will reach the neutrino fog in the 0.5-5 GeV mass range and test a variety of benchmark models and sharp targets. The novel directions involve greater departures from current SuperCDMS technology but promise even greater reach in the long run, and their development must begin now for them to be available in a timely fashion. The experienced-based upgrade scenarios rely mainly on dramatic improvements in detector performance based on demonstrated scaling laws and reasonable extrapolations of current performance. Importantly, these improvements in detector performance obviate significant reductions in background levels beyond current expectations for the SuperCDMS SNOLAB experiment. Given that the dominant limiting backgrounds for SuperCDMS SNOLAB are cosmogenically created radioisotopes in the detectors, likely amenable only to isotopic purification and an underground detector life-cycle from before crystal growth to detector testing, the potential cost and time savings are enormous and the necessary improvements much easier to prototype.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kinetic Inductance Detectors for Dark Matter Searches

Decades of astrophysical observations suggest that 23% of the mass energy of the universe is dark. Meanwhile, particle physics theories favor the existence of a stable and weakly interacting particle, which has yet to be detected. These realities combine to formulate a very well motivated particle dark matter candidate, which was produced in the early universe and still lingers in abundance today. The expectation of a small weak interaction cross-section enables the instrumentation of experiments designed to discover the nature of the dark matter which continues to be an overarching question of cosmology. A detector for this dark matter candidate senses energy from occasional collisions between the dark matter and atomic nuclei; the more nuclei in the detector, the greater its sensitivity to dark matter. The detectors of the Cryogenic Dark Matter Search (CDMS) measure phonons and charge emanating from recoiling germanium nuclei. Its phonon sensors, though exquisitely sensitive, are relatively complicated to fabricate and deploy. Responding to the scientific imperative to increase dark matter sensitivity, we look for a simpler phonon sensor technology. Kinetic inductance based phonon sensors (KIPS) are superconducting thin film microwave frequency resonant circuits. Phonon energy impinging on the film alters its surface impedance, which alters the characteristics of the resonance. KIPS can be made with relatively large, millimeter sized features which makes them easier to fabricate and reduces variations between detectors. This instrumentation focused thesis shows that KIPS can be used as a simple and sensitive phonon sensor for the CDMS detector. KIPS design aspects, competitiveness to the current transition edge phonon sensors, readout considerations and suggestions on how to instrument them in future dark matter experiments will be presented. The broader applicability of KIPS in nuclear non-proliferation and other physics investigations is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sterile Neutrino Search with the NOvA Detectors

NOvA is a two-detector experiment designed to observe neutrino oscillations from νµ toνe flavor states. Additionally, the location of the NOvA Near Detector is well situated to additionally observe short base line oscillations to sterile neutrino states. We expand upon previous NOvA sterile neutrino searches by using a covariance matrix fitting technique. This analysis is the first with NOvA to directly include neutrino interactions in the Near Detector while fitting the data. The NOvA Near Detector’s greater statistics to better constrain our Far Detector uncertainties in addition to increasing the range of Δ m$^2_{41}$ to which we are sensitive.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On Feature, Classifier and Detector Fusers for U-235 Signatures Using Gamma Spectral Counts

Three types of information fusion strategies are studied to assess the performance of classifiers for detecting low-level U-235 radiation sources, using features obtained from gamma spectra of NaI detectors. These three strategies are based on using two spectral region features, fusing eight classifiers of diverse designs, and fusing multiple detectors located at different positions around the source. The inner, middle and outer groups of detectors, within a formation of two concentric circles and a spiral of 21 detectors, are identified based on their distance to the source, which is located at the center. This study provides two main qualitative insights into this classification task. First,the fusion of detectors leads to an overall improved classification performance, least in the inner group, most in the outer group, and in between for the middle group. Second, several classifiers and fusers achieve lower training error which does not translate to lower generalization error, indicating their over-fitting to training data.

Rao, Nageswara↗

Radiation detectors employing contemporaneous detection and decontamination

Radiation detectors and methods of using the radiation detectors that provide a route for surface decontamination during use are described. The detectors utilize light illumination of an internal surface during use. Light is in the longer UV-to-near-infrared spectra and desorbs contamination from internal surfaces of radiation detectors. The methods can be carried out while the detectors are in operation, preventing the appearance of the negative effects of radioactive and non-radioactive contamination during a detection regime and following a detection regime.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of B10Plus+* proportional detectors for neutron coincidence counting

GE-Reuter-Stokes (GERS) has developed a new line of neutron proportional counters, the B10Plus+* proportional counter. The detector design is intended to serve as a cost-effective alternative to traditional {sup 3}He proportional counters in a variety of applications. The detector is a hybrid design 10B-lined tube optimized with the addition of a small quantity of 3He gas to improve the detector performance and efficiency. As a demonstration of the B10Plus+* detector, GERS has constructed a Uranium Neutron Collar (UNCL) system consisting of B-10Plus+* proportional counters. GERS has designed and built a demonstration UNCL system intended to match the performance of a Type-I UNCL design in Pressurized Water Reactor (PWR) geometry operating in thermal mode. GERS offered their system on loan to the International Atomic Energy Agency (IAEA) Safeguards Division of Technical and Scientific Services for an assessment of the detector technology and the demonstration system. We have characterized the demonstration UNCL system and compared its performance with a traditional Type-I UNCL design in regular use by the IAEA. This paper summarizes our findings and observations during the characterization and testing activity. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction and Commissioning of Gas Electron Multiplier (GEM) Detectors in Advanced Assembly Design for Low-Energy Applications at High Rates and Analysis of GEM Data From the Muse Experiment at PSI

The search beyond the Standard Model explores dark matter and a potential fifth force. DarkLight@ARIEL investigates the dark photon as a mediator between ordinary and dark matter. The experiment aims to measure the process e?Ta ? e?TaX ? e?Ta(e?e+), by detecting a charged lepton pair in the final state. The spectrometers will be instrumented with Gas Electron Multiplier (GEM) detectors with minimal material budget for tracking. A novel GEM construction technique is employed for fabricating 25 cm x 40 cm GEM detectors, where all layers are mechanically stretched and assembled within a double frame. The dissertation outlines physics motivation, methods, experimental setup, and the role of GEM detectors in DarkLight. A comprehensive discussion on GEM detectors, focusing on the "NS2" technique, including design, parts, assembly, testing, and performance evaluation will be discussed. The proton has garnered attention due to discrepancies in measuring its charge radius using muonic hydrogen and electron-based methods. The 2010 muonic hydrogen measurement of the proton charge radius Rp = 0.84184(67) fm, showed a significant 7? discrepancy compared to the previously known value of Rp = 0.8775(51) fm, giving rise to the proton radius puzzle. Through simultaneous measurements of e ? p and ? ? p elastic scattering, MUSE facilitates a precise and direct comparison of the proton radius. The physics background of the proton radius puzzle, measurement techniques, the approach adopted by the MUSE experiment, its significance and the experimental setup will be discussed. Furthermore, the role of GEM detectors, along with an in-depth analysis of their data and efficiency will be discussed and evaluated.

Mohammed Prem Nazeer, Sahara↗

CdZnTeSe: Recent advances for radiation detector applications

The quest for cost-effective, high performing room temperature semiconductor detector (RTSD) materials for high energy gamma rays has been continuing for more than three decades. The requirements for RTSD materials, however, are more stringent as compared to other applications unrelated to detection of X- and gamma-rays, mainly due to the requirement of thick detectors for sufficient absorption of high-energy electromagnetic radiation and excellent charge-transport properties. The II-VI compound CdZnTe (CZT) with the composition of 10 atomic % Zn (Cd0.9Zn0.1Te) has been the material of choice over the past several years, and it has dominated the commercial market for RTSD materials and detectors. Despite its commercial success as a room temperature radiation detection material, CZT suffers from a lack of compositional homogeneity on both a micro- and macro-scale and the presence of high concentrations of sub-grain boundary (dislocation walls) networks and secondary phases (Te-rich inclusions). This chapter focuses on the presence of performance-limiting defects in CZT that hinder the yield and elevate the cost of high-quality detectors. The presence of such performance-limiting defects has restricted widespread deployment of CZT for a variety of potential applications, particularly for uses of relatively large detectors where the demands on material perfection are significantly greater. In the recent past, replacing some of the tellurium with selenium in the CZT matrix was found to be very effective in drastically reducing the Te-rich secondary phases and dislocation networks, plus

Roy, Utpal N.↗

Detailed Characterization of CZT Detector Response for Improved Coded-Aperture Imaging Performance

Gamma-ray imaging is a powerful method for locating and quantifying sources of radiation. The coded-aperture technique demonstrates superior angular resolution in comparison to other methods (e.g., Compton reconstruction). In this method, a mask constructed of highly attenuating material encodes the scene as a shadow pattern on a position-sensitive detector; this pattern can then be used to recreate the origin(s) of incident radiation. This is typically done through convolution of the mask and shadow patterns. Iterative methods which attempt to reconstruct the observed shadow pattern using a weighted combination of simulated patterns may also be employed. In either case, errors in event position reconstruction due to detector imperfections alter the shadow pattern and will therefore degrade system performance and may introduce imaging artifacts. These effects can be mitigated with a detailed understanding of such errors – allowing for the generation of representative simulations that include the errors and/or correction of raw imager data to remove the errors. We present a calibration process for a commercially available cadmium zinc telluride (CZT) gamma imager which provides a comprehensive characterization of the spatial and energy dependence of event reconstruction. By illuminating a mask featuring a regular grid of pinholes with a calibration source, the localized response of the detector can be measured with fine granularity. These local responses are combined to generate a full detector response map which can be used to distort simulations in a manner that is representative of the observed detector data. Details of the calibration procedure and an assessment of the impact of its end products on the performance of iterative imaging methods will be presented.

Ziock, Klaus-Peter↗