Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Deployable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Estimating traffic volumes for signalized intersections using connected vehicle data

Recently connected vehicle (CV) technology has received significant attention thanks to active pilot deployments supported by the US Department of Transportation (USDOT). At signalized intersections, CVs may serve as mobile sensors, providing opportunities of reducing dependencies on conventional vehicle detectors for signal operation. However, most of the existing studies mainly focus on scenarios that penetration rates of CVs reach certain level, e.g., 25%, which may not be feasible in the near future. How to utilize data from a small number of CVs to improve traffic signal operation remains an open question. In this work, we develop an approach to estimate traffic volume, a key input to many signal optimization algorithms, using GPS trajectory data from CV or navigation devices under low market penetration rates. To estimate traffic volumes, we model in this paper vehicle arrivals at signalized intersections as a time-dependent Poisson process, which can account for signal coordination. The estimation problem is formulated as a maximum likelihood problem given multiple observed trajectories from CVs approaching to the intersection. An expectation maximization (EM) procedure is derived to solve the estimation problem. Two case studies were conducted to validate our estimation algorithm. One uses the CV data from the Safety Pilot Model Deployment (SPMD) project, in which around 2800 CVs were deployed in the City of Ann Arbor, MI. The other uses vehicle trajectory data from users of a commercial navigation service in China. Mean absolute percentage error (MAPE) of the estimation is found to be 9–12%, based on benchmark data manually collected and data from loop detectors. Finally, considering the existing scale of CV deployments, the proposed approach could be of significant help to traffic management agencies for evaluating and operating traffic signals, paving the way of using CVs for detector-free signal operation in the future.

97 MATHEMATICS AND COMPUTING↗

Large-scale inflatable structures for tunnel protection: a review of the Resilient Tunnel Plug project

The protection of underground civil infrastructure continues to be a high priority for transportation and transit security agencies. In particular, rail transit tunnels running under bodies of water are susceptible to disruptions due to flooding caused by extraordinary climatic events such as hurricanes or other events resulting from human activities. Several events have taken place in the past decades that have demonstrated the need to mitigate vulnerabilities or, at least, minimize the consequences of catastrophic events. Although it is impossible to prevent all situations that can lead to flooding, damage can be substantially decreased by reducing the area affected by the event. To minimize the effects of an event, a possible approach is to compartmentalize the tunnel system by creating temporary barriers that can contain the propagation of flooding until a more permanent solution can be implemented. One way to create a temporary barrier is by the deployment of a large-scale inflatable structure, also known as an inflatable plug. In such an application, the inflatable structure is prepared for placement, either permanently or temporally, and maintained ready for deployment, inflation, and pressurization when needed. The internal plug pressure imparts a normal force against the tunnel wall surface with the friction between the plug and tunnel surfaces opposing axial movement of the plug. The sealing effectiveness depends on the ability of the inflatable structure to self-deploy and fit, without human intervention, to the intricacies of the perimeter of the conduit being sealed. Primary design constraints include having the plug stowed away from the dynamic envelope of the trains and being able to withhold the pressure of the flooding water. This work presents a compilation of the main aspects of the activities completed for the development of large-scale inflatable structures as part of the Resilient Tunnel Plug (RTP) Project. The main test results and lessons learned are presented to demonstrate the viability of implementing large-scale inflatable plugs for the containment of flooding in rail tunnels systems. Over 400 coupon and specimen tests, 200 reduced scale tests, and 100 full-scale tests were conducted to demonstrate the efficacy of the design of different prototypes over a 10-year research and development project. The culmination of the work was 12 large-scale flooding demonstrations where the inflatable tunnel plug was shown able to be deployed remotely and withstand a simulated flooding event.

42 ENGINEERING↗

Moving Beyond 4-Hour Li-Ion Batteries: Challenges and Opportunities for Long(er)-Duration Energy Storage

This report is a continuation of the Storage Futures Study and explores the factors driving the transition from recent storage deployments with four or fewer hours to deployments of storage with greater than four hours. The report specifically builds on the first publication in the Storage Futures Study series, The Four Phases of Storage Deployment: A Framework for the Expanding Role of Storage in the U.S. Power System, that established a conceptual framework of roles and opportunities for new, cost-competitive stationary energy storage over the course of four phases of current and potential future storage deployment. This latest publication delves into Phases 2 and 3 when solar photovoltaics and storage increase the value of each other, and lower costs and technology improvements enable storage to be cost-competitive while serving longer-duration applications.

14 SOLAR ENERGY↗

Strategic Siting of Direct Air Capture Facilities in the United States

Direct air capture (DAC) systems that capture carbon dioxide (CO 2 ) directly from the atmosphere are garnering considerable attention for their potential role as negative emission technologies in achieving net-zero CO 2 emission goals. Common DAC technologies are based either on liquid–solvent (L-DAC) or solid–sorbent (S-DAC) to capture CO 2 . A comprehensive multi-factor comparative economic analysis of the deployment of L-DAC and S-DAC facilities across various United States (U.S.) cities is presented in this paper. The analysis considers the influence of various factors on the favorability of DAC deployment, including local climatic conditions such as temperature, humidity, and CO 2 concentrations; the availability of energy sources to power the DAC system; and costs for the transport and storage of the captured CO 2 along with the consideration of the regional market and policy drivers. The deployment analysis in over 70 continental U.S. cities shows that L-DAC and S-DAC complement each other spatially, as their performance and operational costs vary in different climates. L-DAC is more suited to the hot, humid Southeast, while S-DAC is preferrable in the colder, drier Rocky Mountain region. Strategic deployment based on regional conditions and economics is essential for promoting the commercial adoptability of DAC, which is a critical technology to meet the CO 2 reduction targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of a 300°C 3C Fiber Optic Downhole Seismic Receiver Array for Surveying and Monitoring of Geothermal Reservoirs

To address the critical site characterization and monitoring needs for Enhance Geothermal Systems (EGS) programs, US Department of Energy (DOE) awarded Paulsson, Inc. in 2011 a contract to design, build and test a high temperature fiber optic based ultra-large bandwidth clamped borehole seismic vector array capable of deploying a large number of 3C sensor pods suitable for deployment into high temperature and high pressure boreholes. Paulsson, Inc. has completed a design or a unique borehole seismic system consisting of a novel drill pipe based deployment system that includes a hydraulic clamping mechanism for the sensor pods, a new sensor pod design and most important – a unique fiber optic seismic vector sensor with technical specifications and capabilities that far exceed the state of the art seismic sensor technologies. These novel technologies were all applied to the new borehole seismic system. In combination these technologies will allow for the deployment of up to 1,000 3C sensor pods in vertical, deviated or horizontal wells. Laboratory tests of the fiber optic seismic vector sensors developed during this project have shown that the new borehole seismic sensor technology is capable of generating outstanding high vector fidelity data with extremely large bandwidth: 0.01 – 6,000 Hz. Field tests have shown that the system can record events at magnitudes much smaller than M-4.0 at frequencies over 2,000 Hz. The sensors have also proved to be about 100 times more sensitive than the regular coil geophones that are used in borehole seismic systems today. The fiber optic seismic sensors have furthermore been qualified to operate at temperatures over 300°C (572°F). The data telemetry fibers used for the seismic vector sensors in the system are also used to simultaneously record Distributed Temperature Sensor (DTS) and Distributed Acoustic Sensor (DAS) data allowing additional value added data to be recorded simultaneously with the seismic vector sensor data.

02 PETROLEUM↗

Silicone wristbands compared with traditional polycyclic aromatic hydrocarbon exposure assessment methods

Currently there is a lack of inexpensive, easy-to-use technology to evaluate human exposure to environmental chemicals, including polycyclic aromatic hydrocarbons (PAHs). This is the first study in which silicone wristbands were deployed alongside other PAH exposure assessment methodologies. Wristbands were used within an established Columbia Center for Children’s Environmental Health birth cohort and compared to two traditional personal PAH exposure assessment methods: biological sampling with urine and active air monitoring with samplers (i.e. polyurethane foam (PUF) and filter) housed in backpacks. All samplers were deployed simultaneously on 22 pregnant women for 48-hours. Each woman provided one spot urine sample at the end of the 48-hour period. Sixty-two and 20 PAHs were quantified in the wristbands and PUF/filter, respectively; and eight hydroxy-PAH (OH-PAH) metabolites were quantified in the urine. PAHs in the PUF/filter and OH-PAHs correlate significantly for two of the eight comparisons (rs=0.53 and p=0.01; rs=0.44 and p=0.04). PAHs in the wristband and OH-PAHs correlate significantly for four of the eight comparisons; 1-OH-phenanthrene and 1-OH-pyrene strongly correlate with the parent PAHs in the wristband (rs=0.76 and p=<0.0001; rs=0.66 and p=0.0009). These results suggest wristbands are more closely associated with OH-PAHs in urine than active personal air monitoring methods.

Dixon, Holly M.↗

First Magnetic Resonance Imaging-Guided Aortic Stenting and Cava Filter Placement Using a Polyetheretherketone-Based Magnetic Resonance Imaging-Compatible Guidewire in Swine: Proof of Concept

The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CIRSE Vascular Closure Device Registry

Purpose: Vascular closure devices are routinely used after many vascular interventional radiology procedures. However, there have been no major multicenter studies to assess the safety and effectiveness of the routine use of closure devices in interventional radiology. Methods: The CIRSE registry of closure devices with an anchor and a plug started in January 2009 and ended in August 2009. A total of 1,107 patients were included in the registry. Results: Deployment success was 97.2%. Deployment failure specified to access type was 8.8% [95% confidence interval (95% CI) 5.0-14.5] for antegrade access and 1.8% (95% CI 1.1-2.9) for retrograde access (P = 0.001). There was no difference in deployment failure related to local PVD at the access site. Calcification was a reason for deployment failure in only <0.5% of patients. Postdeployment bleeding occurred in 6.4%, and most these (51.5%) could be managed with light manual compression. During follow-up, other device-related complications were reported in 1.3%: seven false aneurysms, three hematoma >5.9 cm, and two vessel occlusions. Conclusion: The conclusion of this registry of closure devices with an anchor and a plug is that the use of this device in interventional radiology procedures is safe, with a low incidence of serious access site complications. There seems to be no difference in complications between antegrade and retrograde access and other parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy of Length of Virtual Stents in Treatment of Intracranial Wide-Necked Aneurysms

Background and Purpose: Precise stent deployment is important for successful treatment of intracranial aneurysms by stent-assisted coiling (SAC). We evaluated the accuracy of virtual stents generated using commercial stent planning software by comparing the length of virtual and actually deployed intracranial laser cut stents on three-dimensional digital subtraction angiography (3D-DSA) images. Methods: We retrospectively analyzed the data of 75 consecutive cases of intracranial wide-necked aneurysms treated with the SAC technique using laser cut stents. Based on 3D-DSA images acquired by C-arm CT, stent sizing and placement were intraoperatively simulated by a commercial software application. The difference in length of the stents was estimated by measuring proximal discrepancies between the end points of the virtual and actually deployed stents on fused pre-procedural and post-procedural 3D-DSA images. Discrepancies between distal stent end points were manually minimized. The Kruskal–Wallis test was applied to test whether stent location, type, and length had an effect on difference in length between virtual and real stent. Results: The median difference in length between virtual and real stents was 1.58 mm with interquartile range 1.12–2.12 mm. There was no evidence for an effect of stent location (p = 0.23), stent type (p = 0.33), or stent length (p = 0.53) on difference in length between virtual and real stents. Conclusions: Stent planning software allows 3D simulation of laser cut stents overlain on 3D-DSA images of vessels and may thus be useful for stent selection and deployment of laser cut stents during stent-assisted coiling of intracranial aneurysms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Negative emissions and international climate goals—learning from and about mitigation scenarios

For aiming to keep global warming well-below 2 °C and pursue efforts to limit it to 1.5 °C, as set out in the Paris Agreement, a full-fledged assessment of negative emission technologies (NETs) that remove carbon dioxide from the atmosphere is crucial to inform science-based policy making. With the Paris Agreement in mind, we re-analyse available scenario evidence to understand the roles of NETs in 1.5 °C and 2 °C scenarios and, for the first time, link this to a systematic review of findings in the underlying literature. In line with previous research, we find that keeping warming below 1.5 °C requires a rapid large-scale deployment of NETs, while for 2 °C, we can still limit NET deployment substantially by ratcheting up near-term mitigation ambition. Most recent evidence stresses the importance of future socio-economic conditions in determining the flexibility of NET deployment and suggests opportunities for hedging technology risks by adopting portfolios of NETs. Importantly, our thematic review highlights that there is a much richer set of findings on NETs than commonly reflected upon both in scientific assessments and available reviews. In particular, beyond the common findings on NETs underpinned by dozens of studies around early scale-up, the changing shape of net emission pathways or greater flexibility in the timing of climate policies, there is a suite of “niche and emerging findings”, e.g. around innovation needs and rapid technological change, termination of NETs at the end of the twenty-first century or the impacts of climate change on the effectiveness of NETs that have not been widely appreciated. Future research needs to explore the role of climate damages on NET uptake, better understand the geophysical constraints of NET deployment (e.g. water, geological storage, climate feedbacks), and provide a more systematic assessment of NET portfolios in the context of sustainable development goals.

54 ENVIRONMENTAL SCIENCES↗

280 GHz Focal Plane Unit Design and Characterization for the Spider-2 Suborbital Polarimeter

We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne Spider instrument. These FPUs are vital to Spider’s primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mode contamination in the CMB from Galactic dust emission. Each 280 GHz focal plane contains a $16 \times 16$ grid of corrugated silicon feedhorns coupled to an array of aluminum–manganese transition-edge sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the three 280 GHz FPUs contain 1530 polarization-sensitive bolometers (765 spatial pixels) optimized for the low loading environment in flight and read out by time-division SQUID multiplexing. In this paper, we describe the mechanical, thermal, and magnetic shielding architecture of the focal planes and present cryogenic measurements which characterize yield and the uniformity of several bolometer parameters. The assembled FPUs have high yields, with one array as high as 95% including defects from wiring and readout. We demonstrate high uniformity in device parameters, finding the median saturation power for each TES array to be $\sim $ 3 pW at 300 mK with a less than 6% variation across each array at $1\sigma $ . These focal planes will be deployed alongside the 95 and 150 GHz telescopes in the Spider-2 instrument, slated to fly from McMurdo Station in Antarctica in December 2018.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Role of Spectroscopy Versus Detection for Border Security

Countries around the world are deploying radiation portal monitor (RPM) systems and other radiation detection instrumentation to interdict the illegal shipment of radioactive material crossing international borders. These efforts include deployments in the U.S. and in a number of other countries by governments and international organizations. Because of their high efficiency for gamma-ray detection, most deployed RPM systems are based on plastic scintillators. Such systems, however, are largely non-spectroscopic in capability. Fully capable spectroscopic portal monitor systems are undergoing engineering development for deployment in the future. The ability to identify the detected radionuclides may allow improved operational handling of radiation alarms, particularly those arising from the normal cargo stream of naturally occurring radioactive material, commercial radioactive sources, and individuals treated with medical radiopharmaceuticals. The goal for improved RPM systems is to increase the sensitivity to threats while reducing the impact that nuisance alarms have on operations. This paper considers the roles for spectroscopic and non-spectroscopic systems for safeguards and border security.

border security↗

Long-term implications of sustained wind power growth in the United States: Potential benefits and secondary impacts

Here, we model scenarios of the U.S. electric sector in which wind generation reaches 10% of end-use electricity demand in 2020, 20% in 2030, and 35% in 2050. As shown in a companion paper, achieving these penetration levels would have significant implications for the wind industry and the broader electric sector. Compared to a baseline that assumes no new wind deployment, under the primary scenario modeled, achieving these penetrations imposes an incremental cost to electricity consumers of less than 1% through 2030. These cost implications, however, should be balanced against the variety of environmental and social implications of such a scenario. Relative to a baseline that assumes no new wind deployment, our analysis shows that the high-penetration wind scenario yields potential greenhouse-gas benefits of 85–1,230 billion USD in present-value terms, with a central estimate of 400 billion USD. Air-pollution-related health benefits are estimated at 52–272 billion USD, while annual electric-sector water withdrawals and consumption are lower by 15% and 23% in 2050, respectively. We also find that a high-wind-energy future would have implications for the diversity and risk of energy supply, local economic development, and land use and related local impacts on communities and ecosystems; however, these additional impacts may not greatly affect aggregate social welfare owing to their nature, in part, as resource transfers.

17 WIND ENERGY↗

Design of machine learning models with domain experts for automated sensor selection for energy fault detection

Data-driven techniques that extract insights from sensor data reduce the cost of improving system energy performance through fault detection and system health monitoring. To lower cost barriers to widespread deployment, a methodology is proposed that takes advantage of existing sensor data, encodes expert knowledge about the application system to create ‘virtual sensors’ and applies statistical and mathematical methods to reduce the time required for manual configurations. The approach combines sensor data points with encoded expert knowledge that is generic to the application system but independent of a particular deployment, thereby reducing the need to tailor to individual deployments. Additionally, this paper not only presents a method that detects faults from measured energy data, but also (1) describes an engagement method with experts in the energy system domain to identify data, (2) integrates domain knowledge with the data, (3) automatically selects from among the large pool of potential input data, and (4) uses machine learning to automatically build a data-driven fault detection model. Demonstration on a commercial building chiller plant shows that only a small number of virtual sensors is necessary for fault detection with high accuracy rates. This corresponds to the use of only five out of 52 original sensor data points features. With as few as four features, classification F1 scores exceed 90% on the training set and 80% on the testing set. The results are implementable and realizable using off-the-shelf tools. The goal is to design with domain experts an energy monitoring system that can be configured once and then widely deployed with little additional cost or effort.

47 OTHER INSTRUMENTATION↗

Effects of land-based wind turbine upsizing on community sound levels and power and energy density

Multiple technological, social, and market factors of wind power are evolving rapidly. Most notably, significant wind turbine scaling is occurring and is forecasted to continue. While the larger turbines expected to be deployed in the future are more powerful and efficient, they are also expected to operate at higher sound levels and require larger setbacks than those installed in the last decade. These sometimes-competing deployment trends and impacts cannot be understood via simple extrapolations of past trends. This study analyzes the effect of these future larger turbines on wind turbine micro-siting, project-level power and energy density, and community noise impacts. Due to their taller heights, larger rotors, and higher sound power levels, future wind turbines will require larger setbacks from homes and greater inter-turbine spacing, resulting in fewer turbines deployed for a given land area. This research finds these changes more than offset the effect of the higher turbine sound emissions, significantly decreasing the average sound levels that wind plant hosting communities experience. Yet, simultaneously, plant layouts using future turbine designs also result in projects with higher installed capacities and annual energy output for a given land area. These increases will likely lead to increased tax benefits and local income in the community. The deployment of fewer turbines on a smaller number of parcels could have implications on siting flexibility and landowner payments.

17 WIND ENERGY↗

Soft costs and EVSE – Knowledge gaps as a barrier to successful projects

There has been a recent push to increase access to electric vehicle (EV) charging infrastructure. The National Electric Vehicle Infrastructure (NEVI) program, part of the Bipartisan Infrastructure Law (BIL) has made significant funding available for major charging infrastructure projects along state thruways, and many state and local incentives exist for EV owners to install chargers in their homes. However, deployment of these chargers has not kept up with demand, primarily due to issues in project planning, permitting processes, and unforeseen delays. This paper serves as a review of the current understanding of these and other non-hardware costs in EV charging infrastructure projects (collectively known as “soft costs”). We found that soft costs in EV charging infrastructure projects are not well understood. Specifically, there is little agreement on how soft costs should be categorized and tracked, and less agreement still on best practices for controlling these costs and lowering barriers to infrastructure deployment. A broader review of EV charging infrastructure cost analyses shows that these costs can have significant impacts on project outcomes. EV charging infrastructure projects may be able to examine the success of the solar industry in lowering soft costs, and a similar effort may lower project costs significantly. Further work on standardizing and collecting data on EV charging infrastructure costs is required to begin addressing and controlling these costs.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Development of an approach to correcting MicroPEM baseline drift

Highlights: • Unacceptable baseline drift of real-time PM{sub 2.5} data measured by microPEM can lead to exposure miscalculation. • A reliable method was developed to adjust the baseline based on ambient PM{sub 2.5} levels provided by fixed monitoring sites. • It is also critical to tie the real-time data with mass-weighted average optical properties of PM{sub 2.5} collected. • This method can efficiently correct ~ 81% of the measurements with the baseline drift issue. Fine particulate matter (PM{sub 2.5}) is associated with various adverse health outcomes. The MicroPEM (RTI, NC), a miniaturized real-time portable particulate sensor with an integrated filter for collecting particles, has been widely used for personal PM{sub 2.5} exposure assessment. Five-day deployments were targeted on a total of 142 deployments (personal or residential) to obtain real-time PM{sub 2.5} levels from children living in New York City and Baltimore. Among these 142 deployments, 79 applied high-efficiency particulate air (HEPA) filters in the field at the beginning and end of each deployment to adjust the zero level of the nephelometer. However, unacceptable baseline drift was observed in a large fraction (> 40%) of acquisitions in this study even after HEPA correction. This drift issue has been observed in several other studies as well. The purpose of the present study is to develop an algorithm to correct the baseline drift in MicroPEM based on central site ambient data during inactive time periods.

54 ENVIRONMENTAL SCIENCES↗