Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Demonstration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Cavity resonator for dielectric measurements of high-ε, low loss materials, demonstrated with barium strontium zirconium titanate ceramics

A resonant cavity method is presented which can measure loss tangents and dielectric constants for materials with dielectric constant from 150 to 10 000 and above. This practical and accurate technique is demonstrated by measuring barium strontium zirconium titanate bulk ferroelectric ceramic blocks. Above the Curie temperature, in the paraelectric state, barium strontium zirconium titanate has a sufficiently low loss that a series of resonant modes are supported in the cavity. At each mode frequency, the dielectric constant and loss tangent are obtained. The results are consistent with low frequency measurements and computer simulations. A quick method of analyzing the raw data using the 2D static electromagnetic modeling code SuperFish and an estimate of uncertainties are presented.

Marksteiner, Quinn R.↗

Experimental demonstration of a single-spike hard-X-ray free-electron laser starting from noise

In this letter, we report the experimental demonstration of single-spike hard-X-ray free-electron laser pulses starting from noise with multi-eV bandwidth. Here, this is accomplished by shaping a low-charge electron beam with a slotted emittance spoiler and by adjusting the transport optics to optimize the beam-shaping accuracy. Based on elementary free-electron laser scaling laws, we estimate the pulse duration to be less than 1 fs full-width at half-maximum.

43 PARTICLE ACCELERATORS↗

Experimental demonstration of a 5th harmonic mm-wave frequency multiplying vacuum tube

Here, we report the experimental demonstration of a 5th harmonic mm-wave frequency multiplying vacuum electronic device, which uses an over-moded spherical sector output cavity. In this device, a pencil electron beam is helically deflected in a transverse deflecting cavity before entering the output cavity. No magnetic field is required to focus or guide the beam. We built and tested a proof-of-principle device with an output frequency of 57.12 GHz. The measured peak power was 52.67 W at the 5th harmonic of the drive frequency. Power at the 4th, 6th, and 7th harmonics was 33.28 dB lower than that at the 5th harmonic.

43 PARTICLE ACCELERATORS↗

Demonstration of fast-electron populations in a low-pressure, low-power, magnetized RF plasma source

Using x-ray spectroscopy, we demonstrate the existence of 0.3–6 keV electrons in a low-pressure, low-power, magnetized plasma source, heated by an external radio-frequency antenna located at one end of an axisymmetric tandem mirror. X-ray measurements on low-bulk-temperature, T e,b ~ 4 eV, hydrogen, neon, argon, and gas-mixture plasmas show spectra with high-energy tails having a near-Maxwellian form with T e,f up to 650 eV. Furthermore, the fast electrons producing these x-rays have densities in the range of 10 7 –10 9 cm –3 0.01%–1% of the bulk plasma density (up to 3 × 10 11 cm –3 ), and so carry a significant fraction of the plasma energy and represent an important mechanism relevant to power coupling and heat flow in similar plasma sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thin film organic photodetectors for indirect X-ray detection demonstrating low dose rate sensitivity at low voltage operation

Here, developments in the field of organic semiconductors have generated organic photodetectors with high quantum efficiency, wide spectral sensitivity, low power consumption, and unique form factors that are flexible and conformable to their substrate shape. In this work, organic photodetectors coupled with inorganic CsI(Tl) scintillators are used to showcase the low dose rate sensitivity that is enabled when high performance organic photodetectors and scintillator crystals are integrated. The detection capability of these organic-inorganic coupled systems to high energy radiation highlights their potential as an alternative to traditional photomultiplier tubes for nuclear spectroscopy applications. When exposed to Bremsstrahlung radiation produced from an X-ray generator, SubPc:C 60 , AlPcCl:C 70 , and P3HT:PC 61 BM thin film photodetectors with active layer thicknesses less than 100 nm show detection of incident radiation at low and no applied bias. Remarkably low dose rates, down to at least 0.28 µGy/s, were detectable with a characteristic linear relationship between exposure rate and photodetector current output. These devices also demonstrate sensitivities as high as 5.37 mC Gy -1 cm -2 when coupled to CsI(Tl). Additionally, as the tube voltage across the X-ray generator was varied, these organic-inorganic systems showed their ability to detect a range of continuous radiation spectra spanning several hundred keV.

36 MATERIALS SCIENCE↗

Demonstration of a chamber for strain mapping of steel specimens under mechanical load in a hydrogen environment by synchrotron radiation

Here, we demonstrate a hydrogen gas chamber suitable for lattice strain measurements and capturing radiographs of a steel specimen under a mechanical load using high energy synchrotron x-rays. The chamber is suitable for static and cyclic mechanical loading. Experiments were conducted at the 1-ID-E end station of the Advanced Photon Source, Argonne National Laboratory. Diffraction patterns show a high signal-to-noise ratio suitable for lattice strain measurements for the specimen and with minimal scattering and overlap from the gas chamber manufactured from aluminum. In situ radiographs of a specimen in the hydrogen chamber show the ability to track a growing crack and to map the lattice strain around the crack with high spatial and strain resolution.

47 OTHER INSTRUMENTATION↗

First demonstration of improved capsule implosions by reducing radiation preheat in uranium vs gold hohlraums

In indirectly-driven Inertial Confinement Fusion (ICF) implosions, supra-thermal M-band (>2 keV) radiation from principally 4–3 resonance line transitions generated during laser irradiation at the peak power of Au hohlraum walls can preheat the fusion capsule and reduce compressional pressure. Higher Z, un-lined depleted uranium (DU) hohlraums were used for the first time in ICF implosions on the National Ignition Facility (NIF) to reduce M-band radiation levels while keeping the total radiation flux similar to Au hohlraums. First implosions in DU demonstrate an increase in in-flight density (+15%) of high density carbon capsules, and hence in stagnated hot spot temperature (+15%), hot spot x-ray (+200%) and fusion neutron yields (+100%) compared to Au hohlraums. We show analytically that these changes are consistent with the observed 40% reduction in M-band x-ray flux in DU, and are in agreement with 2D hydrodynamic simulations. This result had a major impact on ICF research on the NIF where a significant fraction of high neutron yield implosions are currently using un-lined DU hohlraums.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of femtosecond X-ray pump X-ray probe diffraction on protein crystals

The development of X-ray free-electron lasers (XFELs) has opened the possibility to investigate the ultrafast dynamics of biomacromolecules using X-ray diffraction. Whereas an increasing number of structures solved by means of serial femtosecond crystallography at XFELs is available, the effect of radiation damage on protein crystals during ultrafast exposures has remained an open question. We used a split-and-delay line based on diffractive X-ray optics at the Linac Coherent Light Source XFEL to investigate the time dependence of X-ray radiation damage to lysozyme crystals. For these tests, crystals were delivered to the X-ray beam using a fixed-target approach. The presented experiments provide probe signals at eight different delay times between 19 and 213 femtoseconds after a single pump event, thereby covering the time-scales relevant for femtosecond serial crystallography. Even though significant impact on the crystals was observed at long time scales after exposure with a single X-ray pulse, the collected diffraction data did not show significant signal reduction that could be assigned to beam damage on the crystals in the sampled time window and resolution range. This observation is in agreement with estimations of the applied radiation dose, which in our experiment was clearly below the values expected to cause damage on the femtosecond time scale. The experiments presented here demonstrate the feasibility of time-resolved pump-multiprobe X-ray diffraction experiments on protein crystals.

43 PARTICLE ACCELERATORS↗

Experimental Demonstration of a Latent Heat Storage System for Dispatchable Electricity

Modern electric grids that use intermittent renewables require energy storage to maintain reliability. Many potential solutions exist, but latent heat thermal energy storage shows particularly high potential for low cost grid scale energy storage. In this paper, we present the design and initial experimental results for a lab-scale prototype of a novel latent heat thermal storage system. This version of our prototype used 50 kg of aluminum-silicon alloy as a phase change material, and a novel valved thermosyphon concept to control heat flow from a thermal storage tank to thermoelectric generators for dispatchable electricity production. Our results validate the system: the thermal storage system was able to receive heat input, evenly distribute heat to and from the phase change material with small temperature gradients, and controllably dispatch heat to a heat engine for electricity generation on demand. With the basic principle of this technology demonstrated, our next step will be to evaluate and improve system efficiency.

14 SOLAR ENERGY↗

A neutron diffraction demonstration of long-range magnetic order in the quasicrystal approximant DyCd 6

We have used neutron powder diffraction to demonstrate the existence of long-range antiferromagnetic order of Ising-like Dy moments in the DyCd 6 quasicrystal approximant phase. This cubic compound undergoes a slight distortion to a monoclinic cell at low temperatures. The Néel temperature is 18.0(2) K and the magnetic order of the Dy sublattice may be described in the parent cubic Im 3¯ structure using a combination of two propagation vectors, k 1 = [0 0 0] and k 2 = [1/2 0 1/2], yielding ‘anti-I’ order. Furthermore, when referred to the monoclinic C 2/ c cell, the magnetic structure may be described by a single propagation vector: k = [1 0 0].

36 MATERIALS SCIENCE↗

Demonstration of distributed capacitance compensation in a metal-insulator-metal infrared rectenna incorporating a traveling-wave diode

We experimentally demonstrate that the transmission line impedance of traveling-wave diodes can circumvent resistance-capacitance time-constant limitations of metal-insulator-metal diodes in rectennas operating at optical frequencies. We fabricated low resistance (380 Ω ) and moderate responsivity (0.46 A/W) metal-insulator-metal traveling-wave diodes. When a rectenna incorporating the traveling-wave diode was illuminated with 10.6 μ m radiation, it produced a peak system responsivity of 130 μ A/W and a detectivity of 1.0 × 10 4 Jones. These results agree with the simulated device performance and exceed the response of an equivalent lumped-element metal-insulator-metal rectenna.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental demonstration of energy harvesting from the sky using the negative illumination effect of a semiconductor photodiode

We experimentally demonstrate electric power generation from the coldness of the universe directly, using the negative illumination effect when an infrared semiconductor diode faces the sky. Our theoretical model, accounting for the experimental results, indicates that the performance of such a power generation scheme is strongly influenced by the degree of matching between the responsivity spectrum and the atmospheric transparency window, as well as the quantum efficiency of the diode. A Shockley-Queisser analysis of an ideal optimized diode, taking into consideration the realistic transmissivity spectrum of the atmosphere, indicates the theoretical maximum power density of 3.99 W/m2 with the diode temperature at 293 K. The results here point to a pathway towards night-time power generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent results of the Majorana Demonstrator experiment

The Majorana Demonstrator is searching for neutrinoless double-beta decay in 76Ge with two modular arrays of natural and 76Ge-enriched germanium detectors. It is located at the 4850' level of Sanford Underground Research Facility in Lead, South Dakota, USA, and its total mass of germanium detectors is 44.1 kg, of which 29.7 kg is enriched. The analysis of the first 26 kg-yr of data provides an unprecedented energy resolution of 0.13% in the region of interest at 2039 keV and a background level of 15.4 ±2.0 counts/(FWHM t yr). It establishes the lower limit of the half-life of neutrinoless double beta decay as 2.7 1025 yr in 76Ge at 90% CL. This analysis will be summarized here with an emphasis on the energy determination.

López-Castaño, JM↗

Demonstration of GaN-based metal–insulator–semiconductor junction by hydrogen plasma treatment

We demonstrate a nickel/insulating-GaN (i-GaN)/p-type GaN junction and investigate its electrical properties. The i-GaN is formed by exposure to a low-power hydrogen plasma to passivate the p-GaN layer. Cathodoluminescence spectroscopy of the i-GaN is used to understand the passivation effect of the hydrogen plasma on p-GaN. The junction shows very low leakage (<10−9 A at −50 V), excellent rectifying properties (∼107), high temperature stability, and blue light electroluminescence at forward bias. A bandgap model is proposed to illustrate the electrical properties of hydrogenated p-GaN and to understand the device characteristics.

Yang, Chen (ORCID:0000000230090882)↗

Demonstration of nitrogen-incorporated ultrananocrystalline diamond photocathodes in a RF gun environment

Quantum efficiency (QE), intrinsic emittance, and robustness are the three most important figures of merit for photocathodes, the first two determine the ultimate achievable brightness of an electron beam, and the third one directly correlates with the complications of a beamline design. Nitrogen-incorporated ultrananocrystalline diamond [(N)UNCD] materials are promising candidates for photocathode applications due to their remarkable electron emission performance as well as the moderate vacuum requirement. Two (N)UNCD photocathodes have been characterized in a realistic RF gun environment with the nicely balanced performance of all three figures of merit. In this work, the QE of the first (N)UNCD cathode (stored in air for two years before the test) was found to be 3.8 x 10 –4 using a 262 nm UV laser and a cathode surface field of 30MV/m. It was found that the QE of the second (N)UNCD sample (grown days before the test) was nearly the same and, therefore, demonstrates the exceptional environmental tolerance of the material. The intrinsic emittance of (N)UNCD was measured to be 1.00 μm/mm.

36 MATERIALS SCIENCE↗

Resistive contributions to the stability of DIII-D ITER baseline demonstration discharges

Here, measurements of the plasma response to applied n = 1 perturbations from DIII-D ITER baseline scenario (IBS) demonstration discharges exhibit increasing amplitude prior to disruption inducing mode locking events. Simulations reveal that changes in ideal and resistive stability impact the response in the DIII-D IBS regime, well below the pressure limit of the external kink mode. The dependencies of the response measurements on the plasma normalized internal inductance ℓ i and beta β N are qualitatively consistent with ideal MHD, although in most cases the amplitude of the measurements exceeds predictions, indicating that the experimental discharges are less stable than expected. Resistive MHD simulations of the response show improved compatibility with the measurements, and the closest agreement is obtained by including the experimental plasma rotation in the simulations. Although the input neutral beam torque is near zero, the simulations show that the corresponding level of rotation can lead to nearly complete screening of the pitch-resonant field component at the q = 2 surface. However, the simulation results exhibit a significant weakening of this screening effect at the lowest rotation levels in the data set, concurrent with predictions of elevated response amplitudes that are consistent with measurements. These comparisons with DIII-D data provide a qualitative validation of a linear, resistive MHD response model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance demonstration of vacuum microwave components critical for the operation of the ITER low-field side reflectometer

Final design studies in preparation for manufacturing have been performed for functional components of the vacuum portion of the ITER Low-Field Side Reflectometer (LFSR). These components consist of an antenna array, electron cyclotron heating (ECH) protection mirrors, phase calibration mirrors, and vacuum windows. Evaluation of these components was conducted at the LFSR test facility and DIII-D. The antenna array consists of six corrugated-waveguide antennas for simultaneous profile, fluctuation, and Doppler measurements. A diffraction grating, incorporated into the plasma-facing miter bend, provides protection of sensitive components from stray ECH at 170 GHz. For in situ phase calibration of the LFSR profile reflectometer, an embossed mirror is incorporated into the adjacent miter bend. Measurements of the radiated beam profile indicate that these components have a small, acceptable effect on mode conversion and beam quality. Baseline transmission characteristics of the dual-disk vacuum window are obtained and are used to guide ongoing developments. Preliminary simulations indicate that a surface-relief structure on the window surfaces can greatly improve transmission. The workability of real-time phase measurements was demonstrated on the DIII-D profile reflectometer. The new automated real-time analysis agrees well with the standard post-processing routine.

47 OTHER INSTRUMENTATION↗

Demonstration of plasma mirror capability for the OMEGA Extended Performance laser system

A plasma mirror platform was developed for the OMEGA-EP facility to redirect beams, thus enabling more flexible experimental configurations as well as a platform that can be used in the future to improve laser contrast. The plasma mirror reflected a short pulse focusing beam at 22.5° angle of incidence onto a 12.5 μm thick Cu foil, generating Bremsstrahlung and k α x rays, and accelerating ions and relativistic electrons. By measuring these secondary sources, the plasma mirror key performance metrics of integrated reflectivity and optical quality are inferred. It is shown that for a 5 ± 2 ps, 310 J laser pulse, the plasma mirror integrated reflectivity was 62 ± 13% at an operating fluence of 1670 J cm –2 , and that the resultant short pulse driven particle acceleration and x-ray generation indicate that the on target intensity was 3.1 × 10 18 W cm –2 , which is indicative of a good post-plasma mirror interaction beam optical quality. By deriving the plasma mirror performance metrics from the secondary source scalings, it was simultaneously demonstrated that the plasma mirror is ready for adoption in short pulse particle acceleration and high energy photon generation experiments using the OMEGA-EP system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗