Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Configuration Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Reduced Temperature Cesium Removal from AP-101 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational under Washington River Protection Solutions LLC (WRPS), sends initial low-activity Hanford waste tank supernate feed to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. Laboratory-scale ion exchange processing using TSCR prototypic unit operations continues to contribute toward WRPS establishing accurate process flowsheets for the individual feed campaigns planned for TSCR. This report describes the small-scale ion exchange testing with 14.0 L of diluted and filtered supernate from tank 241-AP-101 (AP-101DF) at 16 °C (62 °F) to demonstrate processing at temperature conditions that are more prototypic of what the TSCR system could experience during colder seasons of the year. Since CST Cs capacity increases with decreasing contact temperature, testing at the lower operating temperature will help to predict the maximum 137 Cs loading onto the CST in the TSCR system. One of the waste acceptance criteria (WAC) for the WTP Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AP-101DF tank waste to meet this criterion, only 0.144% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 694. Testing with AP-101DF matched TSCR prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 62% Cs breakthrough after processing ~1400 BVs of feed; the 50% Cs breakthrough occurred at 1250 BVs. Testing compared to previous AP-107 testing at 16 °C showed ~80 BV increases in volume processed to reach the WAC limit for both lead and lag columns. A similar slope in breakthrough curves for both tests indicates similar kinetic behavior, with variations in feed matrices (Na and Cs concentrations) likely responsible for the deviations in reaching the WAC limit. The Cs effluent from the lag column reached the WAC limit after processing 875 BVs. Anticipating this breakthrough point, the polish column was preemptively installed at 770 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 5.32×10 0 µCi/mL, or 5.6 % Cs breakthrough, after processing all 1400 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extended Sleeve Products Allow Control and Monitoring of Process Fluid Flows Inside Shielding, Behind Walls and Beneath Floors - 13041

Throughout power generation, delivery and waste remediation, the ability to control process streams in difficult or impossible locations becomes increasingly necessary as the complexity of processes increases. Example applications include radioactive environments, inside concrete installations, buried in dirt, or inside a shielded or insulated pipe. In these situations, it is necessary to implement innovative solutions to tackle such issues as valve maintenance, valve control from remote locations, equipment cleaning in hazardous environments, and flow stream analysis. The Extended Sleeve family of products provides a scalable solution to tackle some of the most challenging applications in hazardous environments which require flow stream control and monitoring. The Extended Sleeve family of products is defined in three groups: Extended Sleeve (ESV), Extended Bonnet (EBV) and Instrument Enclosure (IE). Each of the products provides a variation on the same requirements: to provide access to the internals of a valve, or to monitor the fluid passing through the pipeline through shielding around the process pipe. The shielding can be as simple as a grout filled pipe covering a process pipe or as complex as a concrete deck protecting a room in which the valves and pipes pass through at varying elevations. Extended Sleeves are available between roughly 30 inches and 18 feet of distance between the pipeline centerline and the top of the surface to which it mounts. The Extended Sleeve provides features such as ± 1.5 inches of adjustment between the pipeline and deck location, internal flush capabilities, automatic alignment of the internal components during assembly and integrated actuator mounting pads. The Extended Bonnet is a shorter fixed height version of the Extended Sleeve which has a removable deck flange to facilitate installation through walls, and is delivered fully assembled. The Instrument Enclosure utilizes many of the same components as an Extended Sleeve, yet allows the installation of process monitoring instruments, such as a turbidity meter to be placed in the flow stream. The basis of the design is a valve body, which, rather than having a directly mounted bonnet has lengths of concentric pipe added, which move the bonnet away from the valve body. The pipe is conceptually similar to an oil field well, with the various strings of casing, and tubing installed. Each concentric pipe provides a required function, such as the outermost pipes, the valve sleeve and penetration sleeve, which provide structural support to the deck flange. For plug valve based designs, the next inner pipe provides compression on the environmental seals at the top of the body to bonnet joint, followed by the innermost pipe which provides rotation of the plug, in the same manner as an extended stem. Ball valve ESVs have an additional pipe to provide compressive loading on the stem packing. Due to the availability of standard pipe grades and weights, the product can be configured to fit a wide array of valve sizes, and application lengths, with current designs as short as seven inches and as tall as 18 feet. Central to the design is the requirement for no special tools or downhole tools to remove parts or configure the product. Off the shelf wrenches, sockets or other hand tools are all that is required. Compared to other products historically available, this design offers a lightweight option, which, while not as rigidly stiff, can deflect compliantly under extreme seismic loading, rather than break. Application conditions vary widely, as the base product is 316 and 304 stainless steel, but utilizes 17-4PH, and other allows as needed based on the temperature range and mechanical requirements. Existing designs are installed in applications as hot as 1400 deg. F, at low pressure, and separately in highly radioactive environments. The selection of plug versus ball valve, metal versus soft seats, and the material of the seals and seats is all dependent on the application requirements. The design of the Extended Sleeve family of products provides a platform which solves a variety of accessibility problems associated with controlling process flow streams in remote, hard to reach locations in harsh environments. Installation of the equipment described has shown to allow access to flow streams that otherwise would require exceptional means to access and control. The Extended Sleeve family of products provides a scalable solution to both control and monitor process fluid flow through shielding, walls or floors when direct connection is advantageous. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimizing and Exploring Untapped Micro-Hydro Hybrid Systems: a Multi-Objective Approach for Crystal Lake as a Large-Scale Energy Storage Solution

Increasing electricity demand and concerns about climate change and fossil fuel consumption have highlighted the importance of renewable energy resources and storage systems. This paper proposes a method for exploring untapped pumped hydro storage potentials to accommodate intermittent renewable energy generation profiles. Hourly measured data from 2022 in Benzie County, Michigan, United States, were gathered for system sizing and a thorough, realistic analysis. By employing the multi-objective grey wolf optimization algorithm, we formulated optimal sizing and energy-management strategies for three different scenarios. Unlike similar studies, the 3rd with triple objective functions (OFs) scenario aims to maximize both reliability and ecological OFs while minimizing the cost OF. It has shown promising results with multiple solutions, considering economic, environmental, and reliability factors. A case study conducted in Crystal Lake, Michigan, revealed that although Crystal Lake would function only as a micro-hydro power facility, it is a promising and huge storage unit with a substantial storage capacity of around 14.9734GWh. The system investigated is significant in the USA due to its rapid deployment capabilities, minimal construction requirements, and ease of integration with the distribution grid. The fuzzy logic method was employed to identify the best non-dominant solution among the other solutions. Furthermore, these outcomes include a notably low levelized cost of energy at 0.046147$/kWh, a robust index of reliability of 99.705%, and a significant reduction in CO₂ emissions amounting to 7.9142×10 3 tons/year, when considering the triple OFs. The paper’s methodology provides valuable insights for regions aiming to utilize renewable energy from untapped storage sources.

13 HYDRO ENERGY↗

Effect of Feeding Rate on the Cold Cap Configuration in a Laboratory-Scale Melter - 13362

High-level-waste melter feed is converted into glass in a joule-heated melter, where it forms a floating layer of reacting feed, called the cold cap. After the glass-forming phase becomes connected, evolving gases produce bubbles that form a foam layer under the feed. The bubbles coalesce into cavities, from which most of the gases are released around the edges of the cold cap while gases also escape through small shafts in the reacting feed. The foam layer insulates the cold cap from the heat transferred from the molten glass below. The cold cap behavior was investigated in a laboratory-scale assembly with a fused silica crucible. A high-alumina waste simulant was fed into the crucible and the feed charging rate was varied from 3 to 7 mL min{sup -1}. After a fixed amount of time (35 min), feed charging was stopped and the crucible was removed from the furnace and quenched on a copper block to preserve the structure of the cold cap during cooling. During the rapid quenching, thermal cracking of the glass and cold cap allowed it to be broken up into sections for analysis. The effect of the charging rate on the height, area and volume of the cold cap was determined. The size of the bubbles collected in the foam layer under the feed increased as the cold cap expanded and the relationship between these bubbles and temperature will be determined for input into a mathematical model. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EVSE Characterization: V2G EVSE Comparison

As part of the U.S. Department of Energy EVs@Scale consortium Next-Generation Profiles project, results and analysis from the characterization of high-power conductive and wireless charging infrastructure are presented. This characterization is conducted over a wide range of direct current (DC) current and DC voltage operation for nominal test conditions and off-nominal test conditions. Test plans and procedures were developed to define the test configurations and requirements, measurement parameters, and test procedures used throughout testing. Results from a 2024 study conducted on electric vehicle supply equipment (EVSE) characterization by the Idaho National Laboratory (INL) include two bi-directional vehicle-to-grid (V2G) capable EVSEs. These EVSE are referred to as V2G-EVSE9 and V2G-EVSE10. Laboratory testing is conducted at nominal test conditions to characterize the power transfer capabilities, efficiency, power factor, and other power quality metrics of the two DC EVSEs capable of V2G bi-directional power transfer. Results from testing show the performance is consistent for V2G-EVSE9 and V2G-EVSE10 when comparing charging to discharging performance, except for V2G-EVSE10 for power transfer when operating above 70% of the rated DC current. V2G-EVSE10 efficiency is >98% while charging and <91% while discharging at the same operating conditions, near maximum-rated current, at 300VDC. In contrast, V2G-EVSE9 results are consistent for charging and discharging. This EVSE is nearly 96% efficient while charging or discharging when operating over 50% of rated AC power. V2G EVSE performance is also characterized during off-nominal AC grid conditions involving AC voltage deviation (426 VAC to 518 VAC), AC frequency deviation of +2% (58.8 Hz to 61.2 Hz), and AC voltage harmonics injection. Many test conditions have little-to-no impact on performance characteristics of the two EVSEs; however, there are a few notable findings with significant power transfer capability impacts. AC voltage harmonics injection resulted in negative impacts on power quality attributes for both EVSEs, but with no impact on power transfer capability. Off-nominal AC voltage and frequency conditions resulted in unstable or lack of power transfer capability for both EVSEs. V2G-EVSE9 is unable to transfer power when AC voltage is >300V L-N. V2G-EVSE10 is unable to transfer power when AC frequency deviation exceeds +0.8%. V2G energy management system transient response and latency are quantified during laboratory testing. V2G-EVSE9 and V2G-EVSE10 utilize cloud-based V2G energy management systems that command the power transfer level between the EVSE and EV. The latency and response characteristics of the entire systems (web-based user interface, V2G energy management system, cellular communications, and EVSE response) are quantified through laboratory testing for V2G-EVSE9 and V2G-EVSE10. V2G-EVSE9 latency ranges from 0.8 to 1.8 seconds, whereas V2G-EVSE10 latency ranges from 3.4 to 8.8 seconds. The ramp rate to a change in power transfer request also differs between the two EVSEs. V2G-EVSE10 ramp rate ranges from 50% to -250% of rated AC power per second, whereas V2G-EVSE9 rate ranges from 95% to -95% of rated AC power per second. At the highest rate of change in power transfer, V2G-EVSE10 can change from full charge power to full discharge power in less than one second. The V2G EVSE characterization presented in this report provides valuable insights and results for use by numerous entities. This includes modeling and simulation organizations, decision makers, fleet planning, industry stakeholders, and many others involved with the development and deployment of electrified transportation technologies. Additional high-power DC chargers, bidirectional chargers, and inductive power transfer EVSE characterization results are anticipated from additional EVSE brands and models, which will be detailed in future publications in support of the U.S. Department of Energy EVs@Scale consortium Next-Gen Profiles project.

25 ENERGY STORAGE↗

Induction Heating for Tritium Storage Beds (FY19 PDRD Project Summary Report)

Metal hydride beds used for storing hydrogen isotopes at the Savannah River Site are conductively heated and cooled to desorb and absorb gases during storage cycling. While several storage bed configurations have been utilized over the years, many achieve heating by utilizing electric cartridge heaters positioned laterally along the longest axis of the storage bed (FACE Gen 2 Beds). Others achieve heating and cooling through hot and cold nitrogen flow (Gen 1 Beds). While these beds/heating configurations are well-designed for storage cycling operations, it is unclear if they can be regenerated to operating conditions once too much helium has accumulated in them. Full regeneration of hydride beds occurs around 625 - 650 °C. It is unclear if the currently employed electric cartridge heaters in Gen 2 beds can reach these temperatures. Furthermore, since swelling can occur during routine heating operations, it is unclear if existing cartridge heaters in Gen 2 beds can be swapped for higher-power cartridges that can reach 625 - 650 °C . Similarly, nitrogen air flow (to the best of our knowledge) cannot cause Gen 1 beds to reach these temperatures. Thus, existing Gen 1 and Gen 2 beds need to be heated through an alternative method to removal helium, so the beds can either return to normal operation or be disposed of. The goal of this PDRD was to investigate if induction heating can be used for various heating processes involving hydride storage beds (e.g. regeneration, gas cycling, helium heel removal). In the original call for proposals, this PDRD fell under "Gas Processing" area of interest # 3: "Develop methods to deploy alternate ways to heat existing process equipment to minimize impact to glove box environment."

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recovery and calibration of legacy analog data from the Leo Brady Seismic Network for the Source Physics Experiment

The Leo Brady Seismic Network (LBSN) was established in 1960 by Sandia National Laboratories for monitoring underground nuclear tests (UGTs) at the Nevada Test Site— renamed in 2010 to the Nevada National Security Site (NNSS). The LBSN has been in various configurations throughout its existence, but it has been generally comprised of four to six stations at regional distances from the NNSS with evenly spaced azimuthal coverage. Between 1962 and the early 1980s, the LBSN—and a sister network operated by Lawrence Livermore National Laboratory—were the most comprehensive U.S. source of regional seismic data of UGTs. During the pre-digital era, LBSN data were transmitted as frequency-modulated (FM) audio over telephone lines to the NTS and recorded in analog on hi-fi 8-track AMPEX tapes. These tapes have been stored in temperature-stable buildings or bunkers on the NNSS and Kirtland Air Force Base in Albuquerque, NM for decades and contain the sole record of this irreplaceable data from the analog era; full waveforms of UGTs during this time were never routinely converted to digital form. We have been developing a process over the past few years to recover and calibrate data from these tapes, converting them from FM audio to digital waveforms in ground motion units. The calibration of legacy data from the LBSN is still ongoing. To date, we have digitized tapes from 592 separate UGTs. As a proof-of-concept, we calibrated data from the BOXCAR event.

58 GEOSCIENCES↗

Estimate of Gamma Dose Rates from Arrays of Fermi-1 Blanket Elements During the MEDE Process

The Enrico Fermi Atomic Power Plant Unit 1 (Fermi-1) was a sodium-cooled fast breeder reactor located in Monroe County, Michigan. The reactor was powered by a core of enriched uranium metal alloy driver fuel, which was enveloped by an axial and radial blanket material consisting of depleted uranium metal alloyed with 3 wt.% molybdenum. There are 406 axial and 559 radial irradiated sodium-bonded Fermi-1 blanket assemblies in storage at INL, totaling 34 metric tons of heavy metal. Disposal of the Fermi-1 blanket material directly into a geological repository is prohibited due to the reactive characteristic of its bond sodium. A melt drain evaporate (MEDE) process can effectively remove bond sodium from Fermi-1 blanket material. Consequently, planning is underway to apply a MEDE process to treat the 34 metric tons of heavy metal of irradiated Fermi-1 blanket material. Given the irradiated Fermi-1 blanket material’s relatively low power history and 50+ years of decay, it can be treated in a shielded glovebox. To assess the requisite shielding, the dose rates of the Fermi-1 blanket elements in various process configurations are needed. The method to perform the dose rate calculations is to first generate an average source term and associated photon source spectra for the Fermi-1 blanket material in SCALE and then use the associated photon spectra to calculate dose rates using MCNP6.2 in seven representative geometries. Dose rates in rem/h were calculated on contact (1 cm from outer geometry surface), 30 cm away from outer geometry surface, and 1 m from outer geometry surface at axial heights spanning the length of the blanket material within the geometry. The maximum average dose rate for the single Fermi-1 radial blanket element is ~0.60 rem/h, for the Fermi-1 radial blanket assembly ~1.10 rem/h, for the single Fermi-1 axial blanket element ~0.5 rem/h, for the Fermi-1 axial blanket assembly ~1.01 rem/h, for the MEDE can ~ 0.98 rem/h, for the Fermi Storage Canister ~ 0.83 rem/h, and for the MEDE cans in the DOE Standard Canister ~0.51 rem/h. Based on these maximum average values, the bounding dose rates are assumed to be 3× the average dose rates calculated for the axial blanket material and 7.6× the average dose rates calculated for the radial blanket material, based on the distribution of Fermi-1 blanket material assembly burnup.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

UltraSciencenet: High- Performance Network Research Test-Bed

The high-performance networking requirements for next generation large-scale applications belong to two broad classes: (a) high bandwidths, typically multiples of 10Gbps, to support bulk data transfers, and (b) stable bandwidths, typically at much lower bandwidths, to support computational steering, remote visualization, and remote control of instrumentation. Current Internet technologies, however, are severely limited in meeting these demands because such bulk bandwidths are available only in the backbone, and stable control channels are hard to realize over shared connections. The UltraScience Net (USN) facilitates the development of such technologies by providing dynamic, cross-country dedicated 10Gbps channels for large data transfers, and 150 Mbps channels for interactive and control operations. Contributions of the USN project are two-fold: (a) Infrastructure Technologies for Network Experimental Facility: USN developed and/or demonstrated a number of infrastructure technologies needed for a national-scale network experimental facility. Compared to Internet, USN's data-plane is different in that it can be partitioned into isolated layer-1 or layer-2 connections, and its control-plane is different in the ability of users and applications to setup and tear down channels as needed. Its design required several new components including a Virtual Private Network infrastructure, a bandwidth and channel scheduler, and a dynamic signaling daemon. The control-plane employs a centralized scheduler to compute the channel allocations and a signaling daemon to generate configuration signals to switches. In a nutshell, USN demonstrated the ability to build and operate a stable national-scale switched network. (b) Structured Network Research Experiments: A number of network research experiments have been conducted on USN that cannot be easily supported over existing network facilities, including test-beds and production networks. It settled an open matter by demonstrating that the performance of switched connections and Multiple Protocol Label Switching tunnels over routed networks are comparable. Furthermore, such connections can be easily peered, and the performance of the resultant hybrid connections is still comparable to the constituent pure connections. USN experiments demonstrated that Infiniband transport can be effectively extended to wide-area connections of thousands of miles, which opens up new opportunities for efficient bulk data transport. USN provided dedicated connections to Cray X1 supercomputer and helped diagnose TCP performance problems which might have been otherwise incorrectly attributed to traffic on shared connections. USN contributed to the development of transport methods for dedicated connections to other traffic. Recently, experiments were conducted to assess the performance of application acceleration devices that employ flow optimization and data compression methods to improve TCP performance.

99 GENERAL AND MISCELLANEOUS↗

Thermal Analysis for Ion-Exchange Column System

Models have been developed to simulate the thermal characteristics of crystalline silicotitanate ion exchange media fully loaded with radioactive cesium either in a column configuration or distributed within a waste storage tank. This work was conducted to support the design and operation of a waste treatment process focused on treating dissolved, high-sodium salt waste solutions for the removal of specific radionuclides. The ion exchange column will be installed inside a high level waste storage tank at the Savannah River Site. After cesium loading, the ion exchange media may be transferred to the waste tank floor for interim storage. Models were used to predict temperature profiles in these areas of the system where the cesium-loaded media is expected to lead to localized regions of elevated temperature due to radiolytic decay. Normal operating conditions and accident scenarios (including loss of solution flow, inadvertent drainage, and loss of active cooling) were evaluated for the ion exchange column using bounding conditions to establish the design safety basis. The modeling results demonstrate that the baseline design using one central and four outer cooling tubes provides a highly efficient cooling mechanism for reducing the maximum column temperature. In-tank modeling results revealed that an idealized hemispherical mound shape leads to the highest tank floor temperatures. In contrast, even large volumes of CST distributed in a flat layer with a cylindrical shape do not result in significant floor heating.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flow dynamics and heat transfer in simplified battery energy storage systems with heated battery modules

Large-scale energy storage systems (ESSs) composed of batteries show promise in addressing current energy challenges, but dissipation of generated heat is important. Here, this paper focuses on buoyant convective flows in simplified ESS battery racks. Natural convection is not generally the primary cooling strategy but can be important in abnormal scenarios where there is module overheat or potentially thermal runaway. We use computational fluid dynamics to investigate the flow dynamics and heat transfer mechanisms in a simplified parameterized rack design. Despite its simplicity, this configuration produces many of the relevant features expected in real ESSs without details of module geometry or hardware, allowing broad conclusions independent of manufacture-specific designs. We start by providing visualizations of the flowfield and measurements of entrainment, heat flux, and pressure. To characterize the dependence on the system parameters, we develop an integral-scale analysis of the average temperature equation to highlight the dominant source terms. We use results from this analysis to derive a steady network model composed of simple algebraic expressions to provide first-order predictions of entrainment through the rack. The network model leads to a linear scaling of the Reynolds number based on convective mass flux with respect to the Grashof number based on the heat source. We deduce empirical relationships that relate the heat exchanged between modules using a surface-averaged Nusselt number as a function of the local Reynolds and Rayleigh numbers. Lastly, we investigate how space between the modules and rack in the spanwise direction creates flow bypass, resulting in different flow pathways.

Battery thermal management↗

Sodium Ion Expansion Power Block for Distributed CSP

The Sodium Ion Expansion Power Block for Distributed CSP was a three-plus-one-year effort under the Concentrating Solar Power: Advanced Projects Offering Low LCOE Opportunities (CSP: APOLLO) funding program within the U.S. Department of Energy Solar Energy Technologies Office. The primary objective of this project is to develop a dual-stage modular sodium thermal electrochemical converter (Na-TEC) heat engine power block, which can be potentially integrated with either a small-scale dish solar or large-scale heliostats and parabolic trough CSP. Na-TEC is a heat engine that generates electricity through the isothermal expansion of sodium ions. The Na-TEC is a closed system that can theoretically achieve conversion efficiencies above 45% when operating between thermal reservoirs at 1150 K and 550 K. However, thermal designs have confined previous single-stage devices to thermal efficiencies below 20%. To mitigate some of these limitations, we consider dividing the isothermal expansion into two stages; one at the evaporator temperature (1150 K) and another at an intermediate temperature (650 K –1050 K). This dual-stage Na-TEC takes advantage of regeneration and reheating, and could be amenable to better thermal management. In light of this, we first designed and developed a thermo-electrochemical model, and thermodynamically demonstrated how the dual-stage device can improve the efficiency by up to 8% points over the best performing single-stage device. We also established an application regime map for the single- and dual-stage Na-TEC in terms of the power density and the total thermal parasitic loss. Moreover, a thermal design of an axisymmetric dual-stage Na-TEC is developed to guide the scale-up and fabrication of sub-components of prototype module. A reduced-order finite-element model is used in conjunction with a Na-TEC thermodynamic model that was developed to determine the total parasitic heat loss of this dual-stage design. A number of simplifications are applied in the reduced-order model to decrease the computational time while maintaining acceptable accuracy. According to this analysis, a maximum efficiency of 29% and a maximum power output of 125 W can be achieved. Ultimately, we were able to demonstrate thermal efficiency improvements of the Na-TEC heat engine from 19% up to 40.3%, in a dual-stage (non-optimized) prototype module that we designed, fabricated, and tested with high temperature stage at 923 K. Furthermore, a cost-performance analysis for this improved dual-stage design was carried out for distributed-CSP systems. A high-level techno-economic analysis (TEA) explores four scenarios where a Na-TEC is used as the heat engine for a distributed-CSP system. Overnight capital cost and levelized cost of electricity (LCOE) are estimated for a system lifetime of 30 years, revealing that overnight capital costs in a range from $3.57 to $17.71 per We are feasible, which equate to LCOEs from 6.9 to 17.2 cents/kWh e -1 . This analysis makes a significant contribution by concurrently quantifying the efficiency and unit costs for a range of multistage configurations, and demonstrating that a Na-TEC may be a promising alternative to Stirling engines for distributed-CSP systems at residential scale of 1–5 kW e .

14 SOLAR ENERGY↗

Status Update on the High Precision Isotopic Measurements on High Burnup LWR Fuel in 2020

The US Department of Energy (DOE) Office of Nuclear Energy (NE) is currently investigating the feasibility of directly disposing dual-purpose (storage and transportation) canisters (DPCs) in a spent nuclear fuel (SNF) repository. Criticality during the repository performance period (10,000 years or more) is one of the major concerns related to direct disposal of DPCs, specifically as the system undergoes degradation in the repository environment and timeframe. Oak Ridge National Laboratory (ORNL) is developing an as-loaded criticality analysis methodology using full (actinides + fission products) burnup credit that exploits the inherent criticality margin associated with actual canister-specific loading configuration. Burnup credit criticality analysis requires validation of the depletion/decay codes used to generate the burned isotopic inventory of an assembly by comparing the code-predicted inventory with experimentally determined isotopic data. Currently, isotopic measurement data for boiling water reactors (BWR) SNF are limited, and additional measurements will be highly beneficial for BWR burnup credit analysis, which is essential to demonstrate disposability of BWR DPCs. Moreover, new pressurized water reactor (PWR) samples of isotopic measurements will expand the PWR sample population and consequently will greatly improve sample statistics. In turn, this will reduce uncertainty in the computational determination of the isotopic composition of commercial SNF and eliminate additional penalties currently used for lack of data. As part of the isotopic analysis task, eight diverse, high burnup (HBU) samples from several PWR rods are being dissolved and isotopically analyzed to provide high-quality measurement data for PWR SNF to reducing the uncertainties associated with PWR isotopic depletion validation. The isotopics of interest focus on nuclides important to burnup credit, shielding, and decay heat in PWR SNF. Additionally, eight high burnup BWR fuel samples from the Limerick nuclear power plant have been identified for measurement to support reducing uncertainties associated with BWR isotopic depletion validation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Exe-Guard Project

The exe-Guard Project is an alliance between Dominion Virginia Power (DVP), Sandia National Laboratories (SNL), Dartmouth University, and Schweitzer Engineering Laboratories (SEL). SEL is primary recipient on this project. The exe-Guard project was selected for award under DE-FOA-0000359 with CFDA number 81.122 to address Topic Area of Interest 4: Hardened platforms and Systems. The exe-Guard project developed an antivirus solution for control system embedded devices to prevent the execution of unauthorized code and maintain settings and configuration integrity. This project created a white list antivirus solution for control systems capable of running on embedded Linux® operating systems. White list antivirus methods allow only credible programs to run through the use of digital signatures and hash functions. Once a system’s secure state is baselined, white list antivirus software denies deviations from that state because of the installation of malicious code as this changes hash results. Black list antivirus software has been effective in traditional IT environments but has negative implications for control systems. Black list antivirus uses pattern matching and behavioral analysis to identify system threats while relying on regular updates to the signature file and recurrent system scanning. Black list antivirus is vulnerable to zero day exploits which have not yet been incorporated into a signature file update. System scans hamper the performance of high availability applications, as revealed in NIST special publication 1058 which summarizes the impact of blacklist antivirus on control systems: Manual or “on-demand” scanning has a major effect on control processes in that they take CPU time needed by the control process (Sometimes close to 100% of CPU time). Minimizing the antivirus software throttle setting will reduce but not eliminate this effect. Signature updates can also take up to 100% of CPU time, but for a much shorter period than a typical manual scanning process. Control systems are vulnerable to performance losses if off-the-shelf blacklist antivirus solutions aren’t implemented with care. This investment in configuration in addition to constant decommissioning to perform manual signature file updates is unprecedented and impractical. Additionally, control systems are often disconnected or islanded from the network making the delivery of signature updates difficult. Exe-Guard project developed a white list antivirus solution that mitigated the above drawbacks and allows control systems to cost-effectively apply malware protection while maintaining high reliability. The application of security patches can also be minimized since white listing maintains constant defense against unauthorized code execution. Security patches can instead be applied in less frequent intervals where system decommissioning can be scheduled and planned for. Since control systems are less dynamic than IT environments, the feasibility of maintaining a secure baselined state is more practical. Because upgrades are performed in infrequent, calculated intervals, it allows a new security baseline to be established before the system is returned to service. Exe-Guard built on the efforts of SNL under the Code Seal project. SNL demonstrated prototype Trust Anchors on the project which are independent monitoring and control devices that can be integrated into untrustworthy components. The exe-Guard team started with the lessons learned under this project then designed commercial solution for white list malware protection. Malware is a real threat, even on islanded or un-networked installations, since operators can unintentionally install infected files, plug in infected mass storage devices, or infect a piece of equipment on the islanded local area network that can then spread to other connected equipment. Protection at the device level is one of the last layers of defense in a security-in-depth defense model before an asset becomes compromised. This project provided non-destructive intrusion, isolation and automated response solution, achieving a goal of the Department of Energy (DOE) Roadmap to Secure Control Systems. It also addressed CIP-007-R4 which requires asset owners to employ malicious software prevention tools on assets within the electronic security perimeter. In addition, the CIP-007-R3 requirement for security patch management is minimized because white listing narrows the impact of vulnerabilities and patch releases. The exe-Guard Project completed all tasks identified in the statement of project objective and identified additional tasks within scope that were performed and completed within the original budget. The cost share was met and all deliverables were successfully completed and submitted on time. Most importantly the technology developed and commercialized under this project has been adopted by the Energy sector and thousands of devices with exe-Guard technology integrated in them have now been deployed and are protecting our power systems today

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dual-Remote Raman Technology for In-Situ Identification of Tank Waste - 13549

A new Raman spectroscopic system for in-situ identification of the composition of solid nuclear tank waste is being developed by collaborative effort between Pacific Northwest National Laboratory (PNNL) and EIC Laboratories, Inc. The recent advancements in Raman technology allow probing the chemical composition of the tank waste without sample collection. In the newly tested configuration, the Raman probe is installed on the top of the tank riser and sends the incident laser beam to the bottom of the tank, 10 - 70 feet away. The returning light containing chemical information is collected by the Raman probe and is transmitted via fiber optic cable to the spectrometer located outside the tank farm area. This dual remote technology significantly expands currently limited options for the safe rapid in-situ identification of the solid tank waste needed for the retrieval decisions. The developed Raman system was extensively tested for acceptability prior to tank farm deployment. This testing included calibration of the system with respect of the distance between the Raman probe and the sample, incident laser beam angle, and presence of the optical interferences. The Raman system was successfully deployed on Tank C-111 at the US DOE Hanford site. As the result of this deployment, the composition of the hardpan at the bottom of C-111 tank was identified. Further development of the dual-remote Raman technology will provide a significant safety enhancement eliminating the potential of personnel radiation exposure associated with the grab sample collection and expands options of the rapid and cost-effective in-situ chemical analysis of the tank waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Update on the Thermal Hydraulic Investigations of a Horizontal Dry Cask Simulator

The thermal performance of commercial spent nuclear fuel dry storage casks is evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission (NRC). Canistered dry storage cask systems rely on ventilation between the inner canister and the overpack to convect heat away from the canister to the surrounding environment for both horizontal and vertical configurations. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a canister in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. Carefully measured data sets generated from testing of full-sized casks or smaller cask analogs are widely recognized as vital for validating these models. While several testing programs have been previously conducted, these earlier validation studies did not integrate all the physics or components important in a modern, horizontal dry cask system. The purpose of the present investigation is to produce data sets that can be used to benchmark the codes and best practices presently used to determine cladding temperatures and induced cooling air flows in modern horizontal dry storage systems. The horizontal dry cask simulator (HDCS) has been designed to generate this benchmark data and add to the existing knowledge base. The objective of the HDCS investigation is to capture the dominant physics of a commercial dry storage system in a well-characterized test apparatus for any given set of operational parameters. The close coupling between the thermal response of the canister system and the resulting induced cooling air flow rate is of particular importance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hanford WTP LAW Melter Startup and Tuning Feed Material Development - 17065

The U.S. Department of Energy's (DOE) Hanford Site in southeast Washington state is home to 56 million gallons of chemical and radioactive waste stored in underground tanks, the result of more than four decades of plutonium production. To address this challenge, the U.S. Department of Energy contracted Bechtel National, Inc., to design and build the world's largest radioactive waste treatment plant. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) will use vitrification to immobilize most of Hanford's waste. Vitrification involves blending the waste with glass-forming materials, and heating it to high temperature to form molten glass, then pouring it into stainless steel containers. In this glass form, its radioactivity will decay over hundreds to thousands of years. In advance of full operation of WTP, a sequential process of commissioning will be undertaken to ensure the plant operates safely and within design requirements. The first phase of WTP operations will focus on the Low-Activity Waste (LAW) Vitrification Facility and its supporting facilities and systems. Commissioning of the LAW Facility will employ a progressive approach to address the complexity of system operation and introduction of hazards. This approach starts with introduction of low hazard and simple testing configurations, and incrementally increasing the complexity and hazardous makeup of testing feed materials, culminating in fully integrated treatment of radioactive tank waste during hot commissioning. Testing with simulants that are chemically similar to radioactive tank waste introduces significant chemical hazards into treatment systems in the form of nitrogen oxides (NOx) and anhydrous ammonia. A method of testing to allow tuning and demonstration of equipment and to develop operator proficiency prior to introducing these chemical hazards was deemed necessary. To that end, the development and testing of a new 'tuning feed' material is in progress. The tuning feed is important because its use will enable the first-time integration of all LAW Facility process systems. The tuning feed must include key physical and chemical characteristics that correspond to the commissioning simulant and low activity tank waste, without the inherently hazardous materials or toxic off-gas constituents that result from tank waste treatment. Tuning feed is being developed to provide representative melter feed rheology, glass chemistry, cold cap formation, and off-gas generation rate in order to predict system response to actual tank waste to the extent practical. The tuning feed must also be compatible with process equipment and other process streams that will be encountered during the cold commissioning testing program. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scaling Up: Kilolumen Solid-State Lighting Exceeding 100 LPW via Remote Phosphor

This thirty-month project was successful in attaining its ambitious objectives of demonstrating a radically novel 'remote-phosphor' LED light source that can out-perform conventional conformal coated phosphor LED sources. Numerous technical challenges were met with innovative techniques and optical configurations. This product development program for a new generation of solid-state light sources has attained unprecedented luminosity (over 1 kilo-lumen) and efficacy (based on the criterion lumens per 100mw radiant blue). LPI has successfully demonstrated its proprietary technology for optical synthesis of large uniform sources out of the light output of an array of separated LEDs. Numerous multiple blue LEDs illuminate single a phosphor patch. By separating the LEDs from the phosphor, the phosphor and LEDs operate cooler and with higher efficiency over a wide range of operating conditions (from startup to steady state). Other benefits of the system include: better source uniformity, more types of phosphor can be used (chemical interaction and high temperatures are no longer an issue), and the phosphor can be made up from a pre-manufactured sheet (thereby lowering cost and complexity of phosphor deposition). Several laboratory prototypes were built and operated at the expected high performance level. The project fully explored two types of remote phosphor system: transmissive and reflective. The first was found to be well suited for a replacement for A19 type incandescent bulbs, as it was able to replicate the beam pattern of a traditional filament bulb. The second type has the advantages that it is pre-collimate source that has an adjustable color temperature. The project was divided in two phases: Phase I explored a transmissive design and Phase II of the project developed reflective architectures. Additionally, in Phase II the design of a spherical emitting transmissive remote phosphor bulb was developed that is suitable for replacement of A19 and similar light bulbs. In Phase II several new reflective remote phosphor systems were developed and patents applied for. This research included the development of reflective systems in which the short-pass filter operated at a nominal incidence angle of 15{sup o}, a major advancement of this technology. Another goal of the project was to show that it is possible to align multiple optics to multiple LEDs (spaced apart for better thermal management) to within an accuracy in the z-direction of 10 microns or less. This goal was achieved. A further goal was to show it is possible to combine and homogenize the output from multiple LEDs without any flux loss or significant increase in etendue. This goal also was achieved. The following color-coded computer drawing of the Phase 2 reflective remote phosphor prototype gives an idea of the accuracy challenges encountered in such an assembly. The actual setup has less functional clarity due to the numerous items of auxiliary equipment involved. Not only did 10 degrees of freedoms alignment have to be supplied to the LEDs and component prisms as well, but there were also micro-titrating glue dispensers and vacuum hoses. The project also utilized a recently introduced high-index glass, available in small customized prisms. This prototype also embodies a significant advance in thin-film design, by which an unprecedented 98% single-pass efficiency was attained over a 30 degree range of incidence angle (Patents Pending). Such high efficiency is especially important since it applies to the blue light going to the phosphor and then again to the phosphor's light, so that the 'system' efficiency associated with short-pass filter was 95.5%. Other losses have to be kept equally small, towards which a new type of ultra-clear injection-moldable acrylic was discovered and used to make ultra-transparent CPC optics. Several transmissive remote phosphor prototypes were manufactured that could replace screw-in type incandescent bulbs. The CRI of the white light from these prototypes varied from 55 to 93. The system efficiency achieved was between 27 to 29.5 lumens per 100 mw radiant blue. For blue LEDs providing 200mw blue for 1 watt electrical input, these prototypes produced 54 to 59 lumens per watt. The latest blue LEDs (from several manufacturers) are more than twice as efficient as this. So in this case the efficiency of the systems (exclusive of driver losses) would be minimally 108 to 118 lumens per watt. So the systems efficiency of the transmissive remote phosphor was proven to be equal to or greater than if the same LEDs use conformal coated phosphor; with the stated advantages of the remote phosphor system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗