Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Condition reports”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Crystallization of bFGF-DNA Aptamer Complexes Using a Sparse Matrix Designed for Protein-Nucleic Acid Complexes

The Sparse Matrix approach for obtaining lead crystallization conditions has proven to be very fruitful for the crystallization of proteins and nucleic acids. Here we report a Sparse Matrix developed specifically for the crystallization of protein-DNA complexes. This method is rapid and economical, typically requiring 2.5 mg of complex to test 48 conditions. The method was originally developed to crystallize basic fibroblast growth factor (bFGF) complexed with DNA sequences identified through in vitro selection, or SELEX, methods. Two DNA aptamers that bind with approximately nanomolar affinity and inhibit the angiogenic properties of bFGF were selected for co-crystallization. The Sparse Matrix produced lead crystallization conditions for both bFGF-DNA complexes.

Cannone, Jaime J.↗

Mapping the Concentration Distribution of Contaminant Plumes to the Computational Grid of the Plateau to River Model (Ver. 8.3)

This environmental calculation file (ECF) outlines the process conducted for defining the initial condition groundwater plumes for select contaminants of interest (COIs) to the Plateau River model version 8.3 (P2Rv8.3) domain (CP-57037, Model Package Report: Plateau to River Groundwater Model Version 8.3). Various data sources were combined into a single set of files defining plume conditions at time 1/1/2018. The resulting files are intended for use as inputs for transport modeling to support forecasts of the Central Plateau contaminant plume fate and transport.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A parametric experimental study of the slotted-wall boundary condition

An experimental study of slotted upper and lower walls in a two dimensional transonic wind tunnel with solid sidewalls is reported. Results are presented for several slot spacings and slot openness ratios. The experimental data were pressure measurements which were made on an airfoil model and on a sidewall near one of the slotted walls. The slotted-wall boundary condition coefficient, which related the pressure and streamline curvature near the wall, was determined from the wall pressure measurements. The measured wall-induced interference was correlated with the experimental values for the boundary condition coefficient. This correlation was compared with theory.

Everhart, J. L.↗

Enhancement of operational Flexibility of Power Plants Using IN740

Headers are crucial components within diverse industries, especially in the energy sector, as they enable the efficient transfer of fluids. The selection of materials for headers is determined by their specific applications; for example, Grade 91 and Grade 92 steels are commonly utilized. In our research, we recommend the adoption of INCONEL alloy 740 due to its exceptional robustness and heat-resistant characteristics. One critical parameter in header systems is the heat transfer coefficient, which directly influences the efficiency of heat exchange processes and can thereby impact the structural integrity of the headers. This coefficient is closely linked with factors such as the Nusselt number, which is influenced by fluid flow characteristics and thermal properties. The flow direction within headers, whether unidirectional or multidirectional—significantly affects the overall dynamics of heat transfer. This research focuses on exploring the behavior of headers, a specific pipeline system component, using ANSYS simulation software. The study aims to predict heat transfer and mechanical behavior within headers under various conditions through steady-state and transient simulations (parts 1 and 2 of the report). Key parameters such as heat transfer coefficient, velocity, and temperature are examined with the goal of optimizing header design. Part 3 of the report addresses the critical yet underexplored relationship between pressure drop and heat transfer coefficients in the transient flow regime within headers, specifically focusing on smooth horizontal circular tubes. Limited experimental work has been conducted in this area, prompting the need for comprehensive analysis. By leveraging machine learning techniques, this research aims to establish a correlation between pressure drop and heat transfer across various flow conditions, including laminar, transient, quasi-turbulent, and turbulent regimes. The data utilized for this analysis were meticulously gathered from existing literature, capturing simultaneous measurements of pressure drops and heat transfer. Part 4: In the context of power plants, header pipes are essential components that significantly influence system performance by facilitating the collection and distribution of steam. This report highlights the critical role of header pipes in enhancing reliability, efficiency, and overall power plant performance. A key aspect of this investigation is shape optimization, which aims to maximize performance while minimizing material usage. By focusing on shape optimization, this research contributes to improved efficiency and a reduced environmental footprint for power plant installations. The methodology developed in this study emphasizes optimizing header shapes to decrease reliance on expensive alloy materials and lower maintenance costs. Furthermore, a case study was conducted using a header from an operational power plant to validate the proposed optimization techniques. Finally, part 5 addresses the challenges associated with flexible operations in boiler systems, the study outlines several strategies for enhancing the durability and reliability of steam headers. Key approaches include material selection, which involves utilizing advanced materials with superior high-temperature properties and enhanced fatigue resistance to extend the lifespan of steam headers. Design modifications are also recommended, focusing on implementing changes that mitigate thermal stress and cyclic loading to reduce the likelihood of failures under varying operating conditions. Additionally, the study emphasizes the importance of regular inspection and monitoring by establishing rigorous protocols to detect early signs of damage, allowing for timely maintenance and minimizing the risks of catastrophic failures. Furthermore, operational guidelines are developed to minimize the frequency and severity of thermal transients, ensuring stable and efficient operations. Collectively, these strategies provide a robust framework for overcoming the unique challenges posed by flexible operation in boiler systems, ultimately contributing to improved reliability and performance in power plant operations. Through this comprehensive approach, the study not only enhances the understanding of pressure drop and heat transfer relationships but also promotes advancements in design and operation that will benefit the entire power generation industry.

01 COAL, LIGNITE, AND PEAT↗

Freja Studies of the Current-Voltage Relation in Substorm-Related Events

Field-aligned currents and electrostatic potentials play important roles in the coupling between the magnetosphere and the ionosphere. If one assumes that the ionosphere-magnetosphere potential difference is mainly due to the mirror force, one can use the single particle adiabatic kinetic theory to describe the system. From this theory, a linear relationship j(sub II) = KV between field-aligned current density j(sub II) and potential drop V along the same field line can be derived, provided that the potential drop is not too large and not too small. With rare exceptions, observational tests of this relation have mainly concentrated on quiet magnetospheric situations, with acceleration voltages V approx. less than 5 kV. Here we use observations from the Freja satellite of precipitating auroral electrons at 1.700 km altitude to study substorm related events, with acceleration voltages up to 20 keV. The observations are found to be consistent with a linear current-voltage relation even i n these conditions, although with values of the field aligned K lower than previously reported (1-5 x 10(exp 11 S/sq m). This can be explained by lower densities and higher characteristic electron energies in the magnetospheric source region of the precipitating electrons. We analyze the data by three different methods, which are all found to be in general agreement. The results are in agreement with a previous study, where the spectra of precipitating electrons --were indirectly inferred by inversion of data from the EISCAT incoherent scatter radar, thereby validating the use of radar data for studies of auroral electrons. Comparisons with previous studies are made, emphasizing the dependence of the results on the type of auroral structure and magnetospheric conditions.

Olsson, A.↗

Analysis of film cooling in rocket nozzles

Computational Fluid Dynamics (CFD) programs are customarily used to compute details of a flow field, such as velocity fields or species concentrations. Generally they are not used to determine the resulting conditions at a solid boundary such as wall shear stress or heat flux. However, determination of this information should be within the capability of a CFD code, as the code supposedly contains appropriate models for these wall conditions. Before such predictions from CFD analyses can be accepted, the credibility of the CFD codes upon which they are based must be established. This report details the progress made in constructing a CFD model to predict the heat transfer to the wall in a film cooled rocket nozzle. Specifically, the objective of this work is to use the NASA code FDNS to predict the heat transfer which will occur during the upcoming hot-firing of the Pratt & Whitney 40K subscale nozzle (1Q93). Toward this end, an M = 3 wall jet is considered, and the resulting heat transfer to the wall is computed. The values are compared against experimental data available in Reference 1. Also, FDNS's ability to compute heat flux in a reacting flow will be determined by comparing the code's predictions against calorimeter data from the hot firing of a 40K combustor. The process of modeling the flow of combusting gases through the Pratt & Whitney 40K subscale combustor and nozzle is outlined. What follows in this report is a brief description of the FDNS code, with special emphasis on how it handles solid wall boundary conditions. The test cases and some FDNS solution are presented next, along with comparison to experimental data. The process of modeling the flow through a chamber and a nozzle using the FDNS code will also be outlined.

Woodbury, Keith A.↗

Risk of longer-term endocrine and metabolic conditions in the Deepwater Horizon Oil Spill Coast Guard cohort study – five years of follow-up

Abstract Introduction Long-term endocrine and metabolic health risks associated with oil spill cleanup exposures are largely unknown, despite the endocrine-disrupting potential of crude oil and oil dispersant constituents. We aimed to investigate risks of longer-term endocrine and metabolic conditions among U.S. Coast Guard (USCG) responders to the Deepwater Horizon (DWH) oil spill. Methods Our study population included all active duty DWH Oil Spill Coast Guard Cohort members ( N = 45,224). Self-reported spill exposures were ascertained from post-deployment surveys. Incident endocrine and metabolic outcomes were defined using International Classification of Diseases (9th Revision) diagnostic codes from military health encounter records up to 5.5 years post-DWH. Using Cox proportional hazards regression, we estimated adjusted hazard ratios (aHR) and 95% confidence intervals (CIs) for various incident endocrine and metabolic diagnoses (2010–2015, and separately during 2010–2012 and 2013–2015). Results The mean baseline age was 30 years (~ 77% white, ~ 86% male). Compared to non-responders ( n = 39,260), spill responders ( n = 5,964) had elevated risks for simple and unspecified goiter (aHR = 2.09, 95% CI: 1.29–3.38) and disorders of lipid metabolism (aHR = 1.09, 95% CI: 1.00–1.18), including its subcategory other and unspecified hyperlipidemia (aHR = 1.10, 95% CI: 1.01–1.21). The dysmetabolic syndrome X risk was elevated only during 2010–2012 (aHR = 2.07, 95% CI: 1.22–3.51). Responders reporting ever ( n = 1,068) vs. never ( n = 2,424) crude oil inhalation exposure had elevated risks for disorders of lipid metabolism (aHR = 1.24, 95% CI: 1.00–1.53), including its subcategory pure hypercholesterolemia (aHR = 1.71, 95% CI: 1.08–2.72), the overweight, obesity and other hyperalimentation subcategory of unspecified obesity (aHR = 1.52, 95% CI: 1.09–2.13), and abnormal weight gain (aHR = 2.60, 95% CI: 1.04–6.55). Risk estimates for endocrine/metabolic conditions were generally stronger among responders reporting exposure to both crude oil and dispersants (vs. neither) than among responders reporting only oil exposure (vs. neither). Conclusion In this large cohort of active duty USCG responders to the DWH disaster, oil spill cleanup exposures were associated with elevated risks for longer-term endocrine and metabolic conditions.

Denic-Roberts, Hristina↗

Operational stability of rubidium and cesium frequency standards

In the course of testing various rubidium and cesium frequency standards under operational conditions for use in NASA tracking stations, about 55 unit-years of relative frequency measurements for averaging times from 10 to 10 to the 7th power have been accumulated at Goddard Space Flight Center (GSFC). Statistics on the behavior of rubidium and cesium standards under controlled laboratory conditions have been published, but it was not known to what extent the lesser controlled environments of NASA tracking stations affected the performance of the standards. The purpose of this report is to present estimates of the frequency stability of rubidium and cesium frequency standards under operational conditions based on the data accumulated at GSFC.

Lavery, J. E.↗

Pre-Test Assessment of the Upper Bound of the Drag Coefficient Repeatability of a Wind Tunnel Model

A new method is presented that computes a pre{test estimate of the upper bound of the drag coefficient repeatability of a wind tunnel model. This upper bound is a conservative estimate of the precision error of the drag coefficient. For clarity, precision error contributions associated with the measurement of the dynamic pressure are analyzed separately from those that are associated with the measurement of the aerodynamic loads. The upper bound is computed by using information about the model, the tunnel conditions, and the balance in combination with an estimate of the expected output variations as input. The model information consists of the reference area and an assumed angle of attack. The tunnel conditions are described by the Mach number and the total pressure or unit Reynolds number. The balance inputs are the partial derivatives of the axial and normal force with respect to all balance outputs. Finally, an empirical output variation of 1.0 microV/V is used to relate both random instrumentation and angle measurement errors to the precision error of the drag coefficient. Results of the analysis are reported by plotting the upper bound of the precision error versus the tunnel conditions. The analysis shows that the influence of the dynamic pressure measurement error on the precision error of the drag coefficient is often small when compared with the influence of errors that are associated with the load measurements. Consequently, the sensitivities of the axial and normal force gages of the balance have a significant influence on the overall magnitude of the drag coefficient's precision error. Therefore, results of the error analysis can be used for balance selection purposes as the drag prediction characteristics of balances of similar size and capacities can objectively be compared. Data from two wind tunnel models and three balances are used to illustrate the assessment of the precision error of the drag coefficient.

drag coefficient measurement↗

Meteorological Conditions in Urban Sites in Knoxville, USA. 2025

This 2025 dataset, which contains five csv files, reports hourly air temperature, wind speed, solar radiation, incident short wave, reflected short wave, incident long wave, emitted long wave, net radiation, and photosynthetically active radiation (PAR) data measured in urban parks in Knoxville, Tennessee, USA. The sites include Cumberland Estates Park (CEP), Socially Equal Energy Efficient Development (SEEED), West Hills Park (WHP), West View Park (WVP), and Victor Ashe Park (VAP). Air temperature, wind speed, and solar radiation data were obtained from a METER ATMOS 41 All-in-One Weather Station (Pullman, Washington, USA). Incident and emitted radiation (shortwave and longwave) measurements were made using an Apogee (Logan, Utah, USA) net radiometer (Model SN-500-SS). The SQ-521 Full-Spectrum Quantum sensor (Apogee Instruments, Inc) recorded the PAR. The measurement data for all the sites started on January 1, 2025. and all measurement ended on December 31, 2025. This work is a part of a larger study which investigates the impact of soil moisture and plant evapotranspiration on ambient temperature and relative humidity in several city parks in Knoxville, Tennessee.

Salvador, Christian [ORNL] (ORCID:0000000283287777↗

Meteorological Conditions in Urban Sites in Knoxville, USA. 2023

This 2023 dataset, which contains four csv files, reports hourly air temperature, wind speed, solar radiation, incident short wave, reflected short wave, incident long wave, emitted long wave, net radiation, and photosynthetically active radiation (PAR) data measured in urban parks in Knoxville, Tennessee, USA. The sites include Cumberland Estates Park (CEP), Socially Equal Energy Efficient Development (SEEED), West Hills (WHP), and Victor Ashe Park (VAP). Air temperature, wind speed and direction, and solar radiation data were obtained from a METER ATMOS 41 All-in-One Weather Station (Pullman, Washington, USA). Incident and emitted radiation (shortwave and longwave) measurements were made using an Apogee (Logan, Utah, USA) net radiometer (Model SN-500-SS). The SQ-521 Full-Spectrum Quantum sensor (Apogee Instruments, Inc) recorded the PAR. The measurement data for CEP, SEEED, and VAP started on July 1, 2023, while WHP started on August 26, 2023. All measurement ended on December 31, 2023. This work is a part of a larger study which investigates the impact of soil moisture and plant evapotranspiration on ambient temperature and relative humidity in several city parks in Knoxville, Tennessee.

Salvador, Christian [ORNL] (ORCID:0000000283287777↗

Corrosion Testing of Refractory inContact with Molten Glasses Designed for Waste Vitrification - VSL Touchpoint Matrix Glasses

It is known that the predictive life of the refractory ceramic liner of nuclear waste glass melters is conservative, as demonstrated by performance of these materials such as in the Defense Waste Processing Facility (DWPF). The motivation for this task is to maximize the useful life of the melters that will be operated at the Waste Treatment and Immobilization Plant (WTP), which will in turn minimize procurement and disposal costs and melter outage times, as well as to identify maximum loadings in the waste glass of those species that corrode melter components. This task was initiated jointly with Pacific Northwest National Laboratory (PNNL) with the objective to develop a methodology and model to enable more accurate prediction of refractory service life under prototypic conditions from laboratory-scale material corrosion tests. Refractory corrosion is generally reported as physical material loss, measured in units of distance (e.g., inch) or as physical material loss rate, measured in units of distance per time (e.g., inch/day). In post-operational melters, the refractory corrosion is measured directly, sometimes reported as corrosion depth. Crucible tests are used in the laboratory to accelerate the refractory corrosion to facilitate a meaningful measurement in a commensurate amount of time. Crucible tests are particularly useful in understanding refractory corrosion across a large glass composition space, where operational testing would be prohibitive. Some of the critical parameters that are known to influence refractory corrosion by molten glass in a crucible test are temperature, system redox, molten salt phases, glass chemistry, and test duration. The majority of data collected for Monofrax® K-3 (hereafter referred to as K-3) corrosion is from crucible tests, but a small amount comes directly from scaled and production melters. Crucible test data has been collected under varying conditions, whereas data collected from operational melters is relatively fewer and represents conditions specific to the melter campaign. The result is that the published data can be grouped and analyzed in multiple ways, not all of which are readily comparable. The Standard Test Method for Isothermal Corrosion Resistance of Refractories to Molten Glass (ASTM C621) outlines the general guidelines used across industry. That method describes a sealed, static test in which the surface area of the refractory coupon and the volume of glass are fixed. A significant portion of the crucible data pertaining to nuclear waste glasses has been collected in a modified configuration; the most notable differences being the surface area of the refractory coupon to volume of the glass and use of a method for bubbling the melt. To our knowledge, the influence of those parameters on the refractory corrosion has not been quantified. In this work, it was determined that static tests and bubbled tests would be performed. Savannah River National Laboratory (SRNL) was tasked with setting up and performing static testing while PNNL was tasked with setting up and performing bubbled testing. Initial activities were performed to establish laboratory methods that reproduce data comparable to existing data sets of K-3 refractory corrosion by low activity waste (LAW) and high-level waste (HLW) glass compositions. Later activities were focused on refining the test parameters to establish a standard test practice to be used between Laboratories and collecting additional data to be used in the enhanced waste glass model development. This document serves primarily to convey the refractory loss measurement results from corrosion testing of K-3 refractory with waste glass compositions developed for use in the WTP melters. The data will be used in the enhanced property/composition models being developed for waste glass vitrification and melter operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automated unit-level testing with heuristic rules

Software testing plays a significant role in the development of complex software systems. Current testing methods generally require significant effort to generate meaningful test cases. The QUEST/Ada system is a prototype system designed using CLIPS to experiment with expert system based test case generation. The prototype is designed to test for condition coverage, and attempts to generate test cases to cover all feasible branches contained in an Ada program. This paper reports on heuristics sued by the system. These heuristics vary according to the amount of knowledge obtained by preprocessing and execution of the boolean conditions in the program.

Carlisle, W. Homer↗

On the cyclic stress-strain behaviour of a Ni-base superalloy at room temperature

The cyclic stress-strain behavior of Nimonic alloy PE16 was studied at room temperature and at different aging conditions to determine whether the plateau in the cyclic stress-strain curve (CSSC) reported by Arbuthnot (1982) is typical of the room temperature behavior and/or some specific initial microstructural states. Specimen blanks were heat-treated in batches in Ar/H2 (98/2) atmosphere to produce gamma-prime precipitates of different average sizes, but with the volume fraction of gamma-prime precipitates kept constant at about 7 percent at all the heat-treatment conditions. Total axial strain controlled LCF tests were conducted under fully reversed loading (R = -1) at a constant strain rate of 0.004/s, using a servohydraulic machine. The load response in tension and compression was recorded continually, and stress-strain hysteresis loops were recorded at frequent intervals. In the present investigation, the CSSCs of the P16 alloy at room temperature did not display the plateaus reported by Arbuthnot.

Singh, Vakil↗

Pantex Plant Ogallala Aquifer and Perched Groundwater Contingency Plan

The Pantex Plant Ogallala Aquifer and Perched Groundwater Contingency Plan has been developed in accordance with the requirements identified in the: • Interagency Agreement for the Pantex Superfund Site, Article 8.5 Work to be Performed, • Compliance Plan Provision of Hazardous Waste Permit No. 50284, and • Record of Decision for Groundwater, Soil, and Associated Media, Pantex Plant. A Long‐Term Monitoring System Design has been designed to monitor conditions in the perched groundwater including changes in the perched aquifer as a result of implementing the response actions. Monitoring is required for verifying the effectiveness of perched groundwater response actions (i.e., conditions in the perched aquifer are being affected as intended) and for confirming that the perched aquifer and Ogallala Aquifer characterization as defined in the Resource Conservation and Recovery Act Facility Investigation Report and the Corrective Measure Studies/Feasibility Study remains accurate. If monitoring results obtained through the monitoring network identify an unexpected condition or deviation, contingent actions will be considered and implemented as necessary to ensure continued protection of the Ogallala Aquifer and human health and the environment. Potential deviations to expected technology performance may be encountered for each of the four primary response actions that compose the selected remedy for perched groundwater; Playa 1 Pump and Treat System, Southeast Area Pump and Treat System, Southeast Area In‐Situ Bioremediation System (comprised of the Southeast In‐Situ Bioremediation System Original System, Southeast Area In‐Situ Bioremediation System Extension System, Offsite In‐Situ Bioremediation System, Perchlorate/Chromium ISB, Northeast ISB and County Road 8 ISB), and Zone 11 In‐Situ Bioremediation System. Monitoring will also be conducted to determine if there are deviations to the expected characterization, e.g., contaminants not expected as a result of the RCRA Facility Investigation characterization. Deviations to expected conditions in the Ogallala Aquifer could also be encountered if the response actions in the perched groundwater are not performing as expected, i.e., preventing contaminants from migrating to the Ogallala Aquifer. Currently, Pantex has begun investigation of detections of high explosives above groundwater protection standards in wells on the Texas Tech University property and a plume that is moving to the northeast from that area. Due to those detections, this Plan recognizes the fact that future detections in the Ogallala will be focused on first‐ time detections of analytes. After a remedy is determined, this Plan will require modification to address-deviations and contingent actions. This Plan was developed to identify the contingent actions necessary to mitigate impacts resulting from deviations to site conditions or response action performance. The Plan defines the environmental problem being addressed by the response actions, clarifies the expected conditions and objectives of the response actions, and identifies the potential deviations to the response actions (due to site conditions or technology performance) that could be encountered. The deviations were evaluated to determine the likelihood of occurrence, potential impact, and time to respond to avoid impact. The Plan also identifies the monitoring outlined in the Long‐Term Monitoring System Design Report (Consolidated Nuclear Security, 2024) and Sampling Analysis Plan (PanTeXas Deterrence, 2024) that will be used to detect the deviations. Lastly, the Plan specifies the contingent actions that could be implemented in response to the deviations. Because each response focuses on a discrete portion of the perched aquifer and contaminant plume, each response action has a different set of expected conditions, and therefore differing impacts from deviations to the site and technology expectations. As a result, the contingent actions are identified for each response action and potential deviation including specific constituents, location, and conditions. If deviations are encountered that impact the ability of the response action to meet performance objectives, the contingent actions will be focused on ensuring the response action can meet the performance objective. Contingent actions may be implemented as interim actions (ISMs/removal actions) in accordance with the Record of Decision, Interagency Agreement, and Hazardous Waste Permit‐50284, if warranted by the specific circumstances. For deviations to site characterization expected conditions, the contingent action will focus on determination of the source of the deviation, determination of the appropriate response, and evaluation of additional work to be completed. However, if the deviation to characterization impacts the performance of the response action, the contingent action will again focus on ensuring performance objectives can be met. Early source term removals and cleanup actions have been implemented to protect the Ogallala Aquifer. Because of these actions and based on modeling results, the expected conditions in the Ogallala Aquifer are that constituents of concern will not be detected above the Groundwater Protection Standards (GWPSs) nor will they reach potential points of exposure above the GWPS. The primary deviation of concern for the Ogallala is if constituents are detected in the Ogallala Aquifer near or above GWPSs. If it occurs, this change in expected conditions would require further evaluation of site and contaminant characteristics to determine an appropriate course of action. The evaluation would include additional monitoring, source identification, implementation of interim protective measures (if necessary), and delineation of extent. These evaluations are necessary to determine an appropriate response action for the Ogallala. The primary goal of the Plan is to provide for the continued protection of the Ogallala Aquifer and the health of its consumers. In recognition, this Plan presents a flexible and rational approach for making future decisions associated with confirming the change in perched and Ogallala aquifer conditions and identifying a response (technical activities, changes to response actions, regulatory oversight, and public involvement).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Conceptual design of a thermal control system for an inflatable lunar habitat module

NASA is considering the establishment of a manned lunar base within the next few decades. To house and protect the crew from the harsh lunar environment, a habitat is required. A proposed habitat is an spherical, inflatable module. Heat generated in the module must be rejected to maintain a temperature suitable for human habitation. This report presents a conceptual design of a thermal control system for an inflatable lunar module. The design solution includes heat acquisition, heat transport, and heat rejection subsystems. The report discusses alternative designs and design solutions for each of the three subsystems mentioned above. Alternative subsystems for heat acquisition include a single water-loop, a single air-loop, and a double water-loop. The vapor compression cycle, vapor absorption cycle, and metal hydride absorption cycle are the three alternative transport subsystems. Alternative rejection subsystems include flat plate radiators, the liquid droplet radiator, and reflux boiler radiators. Feasibility studies on alternatives of each subsystem showed that the single water-loop, the vapor compression cycle, and the reflux boiler radiator were the most feasible alternatives. The design team combined the three subsystems to come up with an overall system design. Methods of controlling the system to adapt it for varying conditions within the module and in the environment are presented. Finally, the report gives conclusions and recommendations for further study of thermal control systems for lunar applications.

Gadkari, Ketan↗

A Review of Tank 48H Treatment of Tetraphenylborate with Permanganate

Tank 48H contains roughly 270,000 gallons of radioactive waste material. The waste stored in this tank was to be processed in multiple stages utilizing facilities at the Savannah River Site (SRS) almost 30 years ago. The In-Tank Precipitation Process (ITP) was initiated in Tank 48H, which precipitated highly radioactive cesium-137 using sodium tetraphenylborate (NaTPB). While the process succeeded in precipitating the Cs, Sr, and other actinides, it also generated an unexpectedly large amount of benzene. The evolved benzene created a safety concern and made the waste incompatible with further downstream processing. This halted the ITP, and a new method of treatment was required to continue processing the legacy waste contained in Tank 48H. A myriad of treatment options have been proposed with multiple teams of researchers assembled to work on this highly complex issue over the last few decades. This review investigated one potentially viable treatment option, in-tank oxidation with sodium permanganate. Permanganate has been well known in literature as a strong oxidizing agent for organic compounds, as well as being utilized at the Savannah River Site (SRS) in other processes. A small number of studies have been conducted utilizing waste simulants to evaluate the use of permanganate as an oxidant for tetraphenylborate (TPB). A search of the literature and data from these studies indicates that permanganate could be a viable treatment for destruction of TPB in Tank 48H. While the scoping studies had a small number of individual experiments and nonideal conditions, the permanganate decomposed up to 90% of the TPB. A free hydroxide concentration above 1.0 M is required for tank corrosion control. Simulant studies indicate no decrease in TPB decomposition by permanganate until pH 14. The simulant studies show an increase in TPB decomposition as the temperature of the solution is increased to 40 °C. The post-reaction analysis of previous simulant tests did not look at all of the organic degradation products. Investigations into what these organic products are and in what quantity will help guide determinations as to whether the downstream processing facilities are able to handle the material that will be generated. Study on the time frame for the reaction between permanganate and TPB should be investigated as the literature reports only extend out to two weeks reaction time. The permanganate treatment conditions indicate no corrosion control concerns and a longer timescale reaction may be needed for in-tank treatment. In addition, further study would be useful to identify a lower boundary condition for the ratio of TPB and oxidant. The simulant tests applied large excesses of permanganate, and this may be unnecessary. The size constraint of the tank means that there will be practical limitations on the amount of sodium permanganate that can be added to the tank. The amount of permanganate should be minimized as much as possible while still ensuring decomposition of the TPB to minimize the amount of manganese dioxide solids generated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Assessment of Magnetic Conditions for Strong Coronal Heating in Solar Active Regions by Comparing Observed Loops with Computed Potential Field Lines

We report further results on the magnetic origins of coronal heating found from registering coronal images with photospheric vector magnetograms. For two complementary active regions, we use computed potential field lines to examine the global non-potentiality of bright extended coronal loops and the three-dimensional structure of the magnetic field at their feet, and assess the role of these magnetic conditions in the strong coronal heating in these loops. The two active regions are complementary, in that one is globally potential and the other is globally nonpotential, while each is predominantly bipolar, and each has an island of included polarity in its trailing polarity domain. We find the following: (1) The brightest main-arch loops of the globally potential active region are brighter than the brightest main- arch loops of the globally strongly nonpotential active region. (2) In each active region, only a few of the mainarch magnetic loops are strongly heated, and these are all rooted near the island. (3) The end of each main-arch bright loop apparently bifurcates above the island, so that it embraces the island and the magnetic null above the island. (4) At any one time, there are other main-arch magnetic loops that embrace the island in the same manner as do the bright loops but that are not selected for strong coronal heating. (5) There is continual microflaring in sheared core fields around the island, but the main-arch bright loops show little response to these microflares. From these observational and modeling results we draw the following conclusions: (1) The heating of the main-arch bright loops arises mainly from conditions at the island end of these loops and not from their global non-potentiality. (2) There is, at most, only a loose coupling between the coronal heating in the bright loops of the main arch and the coronal heating in the sheared core fields at their feet, although in both the heating is driven by conditions/events in and around the island. (3) The main-arch bright loops are likely to be heated via reconnection driven at the magnetic null over the island. The details of how and where (along the null line) the reconnection is driven determine which of the split-end loops are selected for strong heating. (4) The null does not appear to be directly involved in the heating of the sheared core fields or in the heating of an extended loop rooted in the island. Rather, these all appear to be heated by microflares in the sheared core field.

Gary, G. A.↗