Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computer Codes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

A GATE evaluation of the sources of error in quantitative {sup 90}Y PET

Purpose: Accurate reconstruction of the dose delivered by {sup 90}Y microspheres using a postembolization PET scan would permit the establishment of more accurate dose–response relationships for treatment of hepatocellular carcinoma with {sup 90}Y. However, the quality of the PET data obtained is compromised by several factors, including poor count statistics and a very high random fraction. This work uses Monte Carlo simulations to investigate what impact factors other than low count statistics have on the quantification of {sup 90}Y PET. Methods: PET acquisitions of two phantoms—a NEMA PET phantom and the NEMA IEC PET body phantom-containing either {sup 90}Y or {sup 18}F were simulated using GATE. Simulated projections were created with subsets of the simulation data allowing the contributions of random, scatter, and LSO background to be independently evaluated. The simulated projections were reconstructed using the commercial software for the simulated scanner, and the quantitative accuracy of the reconstruction and the contrast recovery of the reconstructed images were evaluated. Results: The quantitative accuracy of the {sup 90}Y reconstructions were not strongly influenced by the high random fraction present in the projection data, and the activity concentration was recovered to within 5% of the known value. The contrast recovery measured for simulated {sup 90}Y data was slightly poorer than that for simulated {sup 18}F data with similar count statistics. However, the degradation was not strongly linked to any particular factor. Using a more restricted energy range to reduce the random fraction in the projections had no significant effect. Conclusions: Simulations of {sup 90}Y PET confirm that quantitative {sup 90}Y is achievable with the same approach as that used for {sup 18}F, and that there is likely very little margin for improvement by attempting to model aspects unique to {sup 90}Y, such as the much higher random fraction or the presence of bremsstrahlung in the singles data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Extreme Scale Computing to Secure the Nation

Since the dawn of modern electronic computing in the mid 1940's, U.S. national security programs have been dominant users of every new generation of high-performance computer. Indeed, the first general-purpose electronic computer, ENIAC (the Electronic Numerical Integrator and Computer), was used to calculate the expected explosive yield of early thermonuclear weapons designs. Even the U. S. numerical weather prediction program, another early application for high-performance computing, was initially funded jointly by sponsors that included the U.S. Air Force and Navy, agencies interested in accurate weather predictions to support U.S. military operations. For the decades of the cold war, national security requirements continued to drive the development of high performance computing (HPC), including advancement of the computing hardware and development of sophisticated simulation codes to support weapons and military aircraft design, numerical weather prediction as well as data-intensive applications such as cryptography and cybersecurity U.S. national security concerns continue to drive the development of high-performance computers and software in the U.S. and in fact, events following the end of the cold war have driven an increase in the growth rate of computer performance at the high-end of the market. This mainly derives from our nation's observance of a moratorium on underground nuclear testing beginning in 1992, followed by our voluntary adherence to the Comprehensive Test Ban Treaty (CTBT) beginning in 1995. The CTBT prohibits further underground nuclear tests, which in the past had been a key component of the nation's science-based program for assuring the reliability, performance and safety of U.S. nuclear weapons. In response to this change, the U.S. Department of Energy (DOE) initiated the Science-Based Stockpile Stewardship (SBSS) program in response to the Fiscal Year 1994 National Defense Authorization Act, which requires, 'in the absence of nuclear testing, a progam to: (1) Support a focused, multifaceted program to increase the understanding of the enduring stockpile; (2) Predict, detect, and evaluate potential problems of the aging of the stockpile; (3) Refurbish and re-manufacture weapons and components, as required; and (4) Maintain the science and engineering institutions needed to support the nation's nuclear deterrent, now and in the future'. This program continues to fulfill its national security mission by adding significant new capabilities for producing scientific results through large-scale computational simulation coupled with careful experimentation, including sub-critical nuclear experiments permitted under the CTBT. To develop the computational science and the computational horsepower needed to support its mission, SBSS initiated the Accelerated Strategic Computing Initiative, later renamed the Advanced Simulation & Computing (ASC) program (sidebar: 'History of ASC Computing Program Computing Capability'). The modern 3D computational simulation capability of the ASC program supports the assessment and certification of the current nuclear stockpile through calibration with past underground test (UGT) data. While an impressive accomplishment, continued evolution of national security mission requirements will demand computing resources at a significantly greater scale than we have today. In particular, continued observance and potential Senate confirmation of the Comprehensive Test Ban Treaty (CTBT) together with the U.S administration's promise for a significant reduction in the size of the stockpile and the inexorable aging and consequent refurbishment of the stockpile all demand increasing refinement of our computational simulation capabilities. Assessment of the present and future stockpile with increased confidence of the safety and reliability without reliance upon calibration with past or future test data is a long-term goal of the ASC program. This will be accomplished through significant increases in the scientific bases that underlie the computational tools. Computer codes must be developed that replace phenomenology with increased levels of scientific understanding together with an accompanying quantification of uncertainty. These advanced codes will place significantly higher demands on the computing infrastructure than do the current 3D ASC codes. This article discusses not only the need for a future computing capability at the exascale for the SBSS program, but also considers high performance computing requirements for broader national security questions. For example, the increasing concern over potential nuclear terrorist threats demands a capability to assess threats and potential disablement technologies as well as a rapid forensic capability for determining a nuclear weapons design from post-detonation evidence (nuclear counterterrorism).

99 GENERAL AND MISCELLANEOUS↗

Special issue: Advanced stencil-code engineering

Here, stencil codes are compute-intensive algorithms, in which data points arranged in a large grid are being recomputed repeatedly from the values of data points in a predefined neighborhood. This fixed neighborhood pattern is called a stencil. Stencils codes see wide-spread use in computing the discrete solutions of partial differential equations and systems composed of such equations.

97 MATHEMATICS AND COMPUTING↗

Verification of MOOSE/Bison's Heat Conduction Solver Using Combined Spatiotemporal Convergence Analysis

Bison is a computational physics code that uses the finite element method to model the thermo-mechanical response of nuclear fuel. Since Bison is used to inform high-consequence decisions, it is important that its computational results are reliable and predictive. One important step in assessing the reliability and predictive capabilities of a simulation tool is the verification process, which quantifies numerical errors in a discrete solution relative to the exact solution of the mathematical model. One step in the verification process—called code verification—ensures that the implemented numerical algorithm is a faithful representation of the underlying mathematical model, including partial differential or integral equations, initial and boundary conditions, and auxiliary relationships. In this paper, the code verification process is applied to spatiotemporal heat conduction problems in Bison. Simultaneous refinement of the discretization in space and time is employed to reveal any potential mistakes in the numerical algorithms for the interactions between the spatial and temporal components of the solution. For each verification problem, the correct spatial and temporal order of accuracy is demonstrated for both first- and second-order accurate finite elements and a variety of time-integration schemes. Furthermore, these results provide strong evidence that the Bison numerical algorithm for solving spatiotemporal problems reliably represents the underlying mathematical model in MOOSE. The selected test problems can also be used in other simulation tools that numerically solve for conduction or diffusion.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The BURNUP package of applied programs used for computing the isotopic composition of materials of an operating nuclear reactor

This paper described the procedure of implementation and the possibilities of the BURNUP program. The purpose of the program is to predict the change in the nuclear composition of the materials of which a reactor is made in the course of its run and compute the radiation characteristics of the materials after their irradiation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Metabolic Tumor Burden Predicts for Disease Progression and Death in Lung Cancer

Purpose: In lung cancer, stage is an important prognostic factor for disease progression and survival. However, stage may be simply a surrogate for underlying tumor burden. Our purpose was to assess the prognostic value of tumor burden measured by {sup 18}F-fluorodeoxyglucose-positron emission tomography (FDG-PET) imaging. Patients and Methods: We identified 19 patients with lung cancer who had staging PET-CT scans before any therapy, and adequate follow-up (complete to time of progression for 18, and death for 15 of 19). Metabolically active tumor regions were segmented on pretreatment PET scans semi-automatically using custom software. We determined the relationship between times to progression (TTP) and death (OS) and two PET parameters: total metabolic tumor volume (MTV), and standardized uptake value (SUV). Results: The estimated median TTP and OS for the cohort were 9.3 months and 14.8 months. On multivariate Cox proportional hazards regression analysis, an increase in MTV of 25 ml (difference between the 75th and 25th percentiles) was associated with increased hazard of progression and of death (5.4-fold and 7.6-fold), statistically significant (p = 0.0014 and p = 0.001) after controlling for stage, treatment intent (definitive or palliative), age, Karnofsky performance status, and weight loss. We did not find a significant relationship between SUV and TTP or OS. Conclusions: In this study, high tumor burden assessed by PET MTV is an independent poor prognostic feature in lung cancer, promising for stratifying patients in randomized trials and ultimately for selecting risk-adapted therapies. These results will need to be validated in larger cohorts with longer follow-up, and evaluated prospectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypoxia Imaging With FAZA-PET and Theoretical Considerations With Regard to Dose Painting for Individualization of Radiotherapy in Patients With Head and Neck Cancer

Purpose: To evaluate the role of hypoxia positron emission tomography (PET) using [{sup 18}F]fluoroazomycin-arabinoside (FAZA) in head and neck cancer for radiation treatment planning using intensity-modulated radiotherapy and dose painting. Methods and Materials: Eighteen patients with advanced squamous cell head and neck cancer were included. Both FAZA-PET and axial CT were performed using mask fixation. The data were coregistered using software based on mutual information. Contours of tumor (primary gross tumor volume, GTV/CT-P) and lymph node metastases (GTV/CT-N) were outlined manually, and FAZA standardized uptake values (SUVs) were calculated automatically. The hypoxic subvolume (GTV/PET-FAZA) having at least 50% more FAZA uptake than background (mean SUV) neck muscle tissue was contoured automatically within GTV/CT-P (GTV/PET-FAZA-P) and GTV/CT-N (GTV/PET-FAZA-N). Results: The median GTV/PET-FAZA-P was 4.6 mL, representing 10.8% (range, 0.7-52%) of the GTV/CT-P. The GTV/PET-FAZA-P failed to correlate significantly with the GTV/CT-P (p = 0.06). The median GTV/PET-FAZA-N was 4.1 mL, representing 8.3% (range, 2.2-51.3%) of the GTV/CT-N. It was significantly correlated with the GTV/PET-N (p = 0.006). The GTV/PET-FAZA-P was located in a single confluent area in 11 of 18 patients (61%) and was diffusely dispersed in the whole GTV/CT-P in 4 of 18 patients (22%), whereas no hypoxic areas were identified in 3 of 18 patients (17%). The GTV/PET-FAZA-N was outlined as a single confluent region in 7 of 18 patients (39%), in multiple diffuse hypoxic regions in 4 of 18 patients (22%), and was not delineated in 7 of 18 patients (39%). Conclusion: This study demonstrates that FAZA-PET imaging could be used for a hypoxia-directed intensity-modulated radiotherapy approach in head and neck cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and performance of a respiratory amplitude gating device for PET/CT imaging

Purpose: Recently, the authors proposed a free-breathing amplitude gating (FBAG) technique for PET/CT scanners. The implementation of this technique required specialized hardware and software components that were specifically designed to interface with commercial respiratory gating devices to generate the necessary triggers required for the FBAG technique. The objective of this technical note is to introduce an in-house device that integrates all the necessary hardware and software components as well as tracks the patient's respiratory motion to realize amplitude gating on PET/CT scanners. Methods: The in-house device is composed of a piezoelectric transducer coupled to a data-acquisition system in order to monitor the respiratory waveform. A LABVIEW program was designed to control the data-acquisition device and inject triggers into the PET list stream whenever the detected respiratory amplitude crossed a predetermined amplitude range. A timer was also programmed to stop the scan when the accumulated time within the selected amplitude range reached a user-set interval. This device was tested using a volunteer and a phantom study. Results: The results from the volunteer and phantom studies showed that the in-house device can detect similar respiratory signals as commercially available respiratory gating systems and is able to generate the necessary triggers to suppress respiratory motion artifacts. Conclusions: The proposed in-house device can be used to implement the FBAG technique in current PET/CT scanners.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-07: An Improved Technique for Scatter Correction in PET

Purpose: In positron emission tomography (PET), the single scatter simulation (SSS) algorithm is widely used for scatter estimation in clinical scans. However, bias usually occurs at the essential steps of scaling the computed SSS distribution to real scatter amounts by employing the scatter-only projection tail. The bias can be amplified when the scatter-only projection tail is too small, resulting in incorrect scatter correction. To this end, we propose a novel scatter calibration technique to accurately estimate the amount of scatter using pre-determined scatter fraction (SF) function instead of the employment of scatter-only tail information. Methods: As the SF depends on the radioactivity distribution and the attenuating material of the patient, an accurate theoretical relation cannot be devised. Instead, we constructed an empirical transformation function between SFs and average attenuation coefficients based on a serious of phantom studies with different sizes and materials. From the average attenuation coefficient, the predicted SFs were calculated using empirical transformation function. Hence, real scatter amount can be obtained by scaling the SSS distribution with the predicted SFs. The simulation was conducted using the SimSET. The Siemens Biograph™ 6 PET scanner was modeled in this study. The Software for Tomographic Image Reconstruction (STIR) was employed to estimate the scatter and reconstruct images. The EEC phantom was adopted to evaluate the performance of our proposed technique. Results: The scatter-corrected image of our method demonstrated improved image contrast over that of SSS. For our technique and SSS of the reconstructed images, the normalized standard deviation were 0.053 and 0.182, respectively; the root mean squared errors were 11.852 and 13.767, respectively. Conclusion: We have proposed an alternative method to calibrate SSS (C-SSS) to the absolute scatter amounts using SF. This method can avoid the bias caused by the insufficient tail information and therefore improve the accuracy of scatter estimation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reduced dose measurement of absolute myocardial blood flow using dynamic SPECT imaging in a porcine model

Purpose: Absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurements provide important additional information over traditional relative perfusion imaging. Recent advances in camera technology have made this possible with single-photon emission tomography (SPECT). Low dose protocols are desirable to reduce the patient radiation risk; however, increased noise may reduce the accuracy of MBF measurements. The authors studied the effect of reducing dose on the accuracy of dynamic SPECT MBF measurements. Methods: Nineteen 30–40 kg pigs were injected with 370 + 1110 MBq of Tc-99m sestamibi or tetrofosmin or 37 + 111 MBq of Tl-201 at rest + stress. Microspheres were injected simultaneously to measure MBF. The pigs were imaged in list-mode for 11 min starting at the time of injection using a Discovery NM 530c camera (GE Healthcare). Each list file was modified so that 3/4, 1/2, 1/4, 1/8, 1/16, and 1/32 of the original counts were included in the projections. Modified projections were reconstructed with CT-based attenuation correction and an energy window-based scatter correction and analyzed with FlowQuant kinetic modeling software using a 1-compartment model. A modified Renkin-Crone extraction function was used to convert the tracer uptake rate K1 to MBF values. The SPECT results were compared to those from microspheres. Results: Correlation between SPECT and microsphere MBF values for the full injected activity was r ≥ 0.75 for all 3 tracers and did not significantly degrade over all count levels. The mean MBF and MFR and the standard errors in the estimates were not significantly worse than the full-count data at 1/4-counts (Tc99m-tracers) and 1/2-counts (Tl-201). Conclusions: Dynamic SPECT measurement of MBF and MFR in pigs can be performed with 1/4 (Tc99m-tracers) or 1/2 (Tl-201) of the standard injected activity without significantly reducing accuracy and precision.

60 APPLIED LIFE SCIENCES↗

Graph-state basis for Pauli channels

Quantum capacities of Pauli channels are not additive, a degenerate quantum code may improve the hashing bound of the capacity. The difficulty in approaching the capacity is how to calculate the coherent information of a generic degenerate quantum code. Using graph state basis, we greatly reduce the problem for the input of quantum error-correcting code. We show that for a graph diagonal state passing through a Pauli channel the output state is diagonalizable and the joint output state of the system and ancilla is block diagonalizable. When the input state is an equal probable mixture of codewords of a stabilizer code, the coherent information can be analytically obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Programming (Tips) for Physicists & Engineers

Programming for today's physicists and engineers. Work environment: today's astroparticle, accelerator experiments and information industry rely on large collaborations. Need more than ever: code sharing/resuse, code building--framework integration, documentation and good visualization, working remotely, not reinventing the wheel.

97 MATHEMATICS AND COMPUTING↗

Verification of a neutronic code for transient analysis in reactors with Hex-z geometry

Due to the geometry of the fuel bundles, to simulate reactors such as VVER reactors it is necessary to develop methods that can deal with hexagonal prisms as basic elements of the spatial discretization. The main features of a code based on a high order finite element method for the spatial discretization of the neutron diffusion equation and an implicit difference method for the time discretization of this equation are presented and the performance of the code is tested solving the first exercise of the AER transient benchmark. The obtained results are compared with the reference results of the benchmark and with the results provided by PARCS code. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design Study Of Cyclotron Magnet With Permanent Magnet

Low energy cyclotrons for Positron emission tomography (PET) have been wanted for the production of radio-isotopes after 2002. In the low energy cyclotron magnet design, increase of magnetic field between the poles is needed to make a smaller size of magnet and decrease power consumption. The Permanent magnet can support this work without additional electric power consumption in the cyclotron. In this paper the study of cyclotron magnet design using permanent magnet is shown and also the comparison between normal magnet and the magnet which is designed with permanent magnet is shown. Maximum energy of proton is 8 MeV and RF frequency is 79.3 MHz. 3D CAD design was done by CATIA P3 V5 R18 and the All field calculations had been performed by OPERA-3D TOSCA. The self-made beam dynamics program OPTICY is used for making isochronous field and other calculations.

43 PARTICLE ACCELERATORS↗

Software realization of real-time neutrons and {gamma}-rays pulse shape discrimination using CUDA platform

The two pulse shape discrimination methods were implemented in real-time. The pulse gradient analysis method was implemented programmatically on PC. The method based on artificial neural network was programmatically implemented using CUDA platform. It is shown that both implementations can provide up to 10{sup 6} pulses per second processing performance. The results for pulse shape discrimination using polycrystalline stilbene and LiF detectors were shown. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-66: Radiomics and Image Registration Updates for the Computational Environment for Radiotherapy Research (CERR)

Purpose: To present new tools in CERR for Radiomics, image registration and other software updates and additions. Methods: Radiomics: CERR supports generating 3-D texture metrics based on gray scale co-occurance. Two new ways to calculate texture features were added: (1) Local Texture Averaging: Local texture is calculated around a voxel within the userdefined bounding box. The final texture metrics are the average of local textures for all the voxels. This is useful to detect any local texture patterns within an image. (2) Image Smoothing: A convolution ball of user-defined radius is rolled over an image to smooth out artifacts. The texture metrics are then computed on the smooth image. Image Registration: (1) Support was added to import deformation vector fields as well as non-deformable transformation matrices generated by vendor software and stored in standard DICOM format. (2) Support was added to use image within masks while computing image deformations. CT to MR registration is supported. This registration uses morphological edge information within the images to guide the deformation process. In addition to these features, other noteworthy additions to CERR include (1) Irregularly shaped ROI: This is done by taking intersection between infinitely extended irregular polygons drawn on any of the two views. Such an ROI is more conformal and useful in avoiding any unwanted parts of images that cannot be avoided with the conventional cubic box. The ROI is useful to generate Radiomics metrics. (2) Ability to insert RTDOSE in DICOM format to existing CERR plans. (3) Ability to import multi-frame PET-CT and SPECT-CT while maintaining spatial registration between the two modalities. (4) Ability to compile CERR on Unix-like systems. Results: The new features and updates are available via https://www.github.com/adityaapte/cerr . Conclusion: Features added to CERR increase its utility in Radiomics, Image-Registration and Outcomes modeling.

07 ISOTOPE AND RADIATION SOURCES↗

Critical and Subcritical 0-Power Experiment at Rensselaer (CaSPER)

This report discusses the 0-power experiment at Rensselaer Polytechnic Institute (CaSPER). K eff simulation results, list-mode multiplication results, and related work are included. The aim of the work is subcritical measurements for code and nuclear data validation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of accuracy of calculations of VVER-1000 core states with incomplete covering of fuel by the absorber

An additional verification of bundled software (BS) SAPFIR-95 and amp;RC [1] and code KORSAR/GP [2] was performed. Both software products were developed in A.P. Alexandrov NITI and certified by ROSTEKHNADZOR of RF for numeric simulation of stationary, transitional and emergency conditions of VVER reactors. A benchmark model for neutronics calculations was created within the limits of this work. The cold subcritical state of VVER - 1000 reactor stationary fuelling was simulated on the basis of FA with an increased height of the fuel column (TVS-2M) considering detailed presentation of radial and front neutron reflectors. A case of passing of pure condensate slug through the core in initially deep subcritical state during start of the first RCP set after refueling was considered as an examined condition of reactor operation. A relatively small size of the slug, its spatial position near the reflectors (lower and lateral), as well as failure of the inserted control rods of the control and protection system (CPS CR) to reach the lower limit of the fuel column stipulate for methodical complexity of a correct calculation of the neutron multiplication constant (K{sub eff}) using engineering codes. Code RC was used as a test program in the process of reactor calculated 3-D modeling. Code MCNP5 [3] was used as the precision program, which solves the equation of neutrons transfer by Monte-Carlo method and which was developed in the US (Los-Alamos). As a result of comparative calculations dependency of K{sub eff} on two parameters was evaluated - boron acid concentration (Cb) and CPS CR position. Reactivity effect was evaluated, which is implemented as a result of failure of all CPS control rods to reach the lower fuel limit calculated using the engineering codes mentioned above. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗