Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building Energy Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

A modeling comparison of deep greenhouse gas emissions reduction scenarios by 2030 in California

California aims to reduce greenhouse gas (GHG) emissions to 40% below 1990 levels by 2030. We compare six energy models that have played various roles in informing the state policymakers in setting climate policy goals and targets. These models adopt a range of modeling structures, including stock-turnover back-casting models, a least-cost optimization model, macroeconomic/macro-econometric models, and an electricity dispatch model. Results from these models provide useful insights in terms of the transformations in the energy system required, including efficiency improvements in cars, trucks, and buildings, electrification of end-uses, low- or zero-carbon electricity and fuels, aggressive adoptions of zero-emission vehicles (ZEVs), demand reduction, and large reductions of non-energy GHG emissions. Some of these studies also suggest that the direct economic costs can be fairly modest or even generate net savings, while the indirect macroeconomic benefits are large, as shifts in employment and capital investments could have higher economic returns than conventional energy expenditures. These models, however, often assume perfect markets, perfect competition, and zero transaction costs. They also do not provide specific policy guidance on how these transformative changes can be achieved. Greater emphasis on modeling uncertainty, consumer behaviors, heterogeneity of impacts, and spatial modeling would further enhance policymakers' ability to design more effective and targeted policies. Here, this paper presents an example of how policymakers, energy system modelers and stakeholders interact and work together to develop and evaluate long-term state climate policy targets. Lastly, even though this paper focuses on California, the process of dialogue and interactions, modeling results, and lessons learned can be generally adopted across different regions and scales.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Estimation of High-Altitude Electromagnetic Pulse Signal Leakage into Power Generation Facilities: Simulations and Measurements

The coupling of early-time high-altitude electromagnetic pulse signals into a power generation facility was investigated. This study encompasses both electromagnetic simulation and on-site experimental efforts that are relevant to shielding effectiveness estimation with a passive technique. As an initial step in understanding the attenuation models involved, simulations were carried out as a function of frequency, building properties, and signal incidence angle. Testing was then performed at the US Department of Energy’s Oak Ridge National Laboratory campus to identify the equipment needed for signal collection and to fine-tune the experimental procedure. Finally, as an application of the models and methods presented, measurements were conducted at a power generation plant to derive the field transfer functions and coupled high-altitude electromagnetic pulse waveforms for various locations within the facility.

42 ENGINEERING↗

Long-Term Results from Evaluation of Advanced New Construction Packages in Test Homes: Lake Elsinore, California

This report presents the long-term evaluation results from a hot-dry climate project that examines the room-to-room temperature conditions that exist in a high performance envelope, the performance of a simplified air distribution system, and a comparison of modeled energy performance with measured energy use. The project, a prototype house built by K. Hovnanian Homes' Ontario Group, is located in Lake Elsinore, Riverside County, California, and achieves a 50% level of whole house source energy savings with respect to the Building America (BA) Benchmark Definition 2009 (Hendron and Engebrecht 2010). Temperature measurements in three rooms indicate that the temperature difference between the measured locations and the thermostat were within recommendations 90.3% of the time in heating mode and 99.3% of the time in cooling mode. The air distribution system is operating efficiently with average delivered temperatures adequate to facilitate proper heating and cooling and only minor average temperature differences observed between the system's plenum and farthest register. Monitored energy use results for the house indicate that it is using less energy than predicted from modeling. A breakdown of energy use according to end use determined little agreement between comparable values.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-Term Results from Evaluation of Advanced New Construction Packages in Test Homes: Lake Elsinore, California

This report presents the long-term evaluation results from a hot-dry climate project that examines the room-to-room temperature conditions that exist in a high performance envelope, the performance of a simplified air distribution system, and a comparison of modeled energy performance with measured energy use. The project, a prototype house built by K. Hovnanian Homes’ Ontario Group, is located in Lake Elsinore, Riverside County, California, and achieves a 50% level of whole house source energy savings with respect to the Building America (BA) Benchmark Definition 2009 (Hendron and Engebrecht 2010). Temperature measurements in three rooms indicate that the temperature difference between the measured locations and the thermostat were within recommendations 90.3% of the time in heating mode and 99.3% of the time in cooling mode. The air distribution system is operating efficiently with average delivered temperatures adequate to facilitate proper heating and cooling and only minor average temperature differences observed between the system’s plenum and farthest register. Monitored energy use results for the house indicate that it is using less energy than predicted from modeling. A breakdown of energy use according to end use determined little agreement between comparable values.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-Term Results from Evaluation of Advanced New Construction Packages in Test Homes: Lake Elsinore, Californi

This report presents the long-term evaluation results from a hot-dry climate project that examines the room-to-room temperature conditions that exist in a high performance envelope, the performance of a simplified air distribution system, and a comparison of modeled energy performance with measured energy use. The project, a prototype house built by K. Hovnanian Homes’ Ontario Group, is located in Lake Elsinore, Riverside County, California, and achieves a 50% level of whole house source energy savings with respect to the Building America (BA) Benchmark Definition 2009 (Hendron and Engebrecht 2010). Temperature measurements in three rooms indicate that the temperature difference between the measured locations and the thermostat were within recommendations 90.3% of the time in heating mode and 99.3% of the time in cooling mode. The air distribution system is operating efficiently with average delivered temperatures adequate to facilitate proper heating and cooling and only minor average temperature differences observed between the system’s plenum and farthest register. Monitored energy use results for the house indicate that it is using less energy than predicted from modeling. A breakdown of energy use according to end use determined little agreement between comparable values.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sienna Modeling Framework [Slides]

NREL's Sienna modeling framework effectively builds, solves, and analyzes the scheduling problems and dynamic simulations of quasi-static infrastructure systems. It uses a modular framework to answer different questions about future energy systems, fundamentally advancing the nation's ability to model individual and integrated infrastructure systems at a range of spatial and temporal scales. This presentation will include NREL power grid researcher Clayton Barrows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermo-hydraulic steam pipe models for district heating simulations: Simplifications to balance accuracy and simulation speed

Steam piping networks are essential for optimizing performance in industrial processes and district heating systems. However, dynamic models that balance thermo-hydraulic accuracy with computational efficiency remain limited. In response, this paper presents a new discretized steam pipe model based on the plug flow approach, capturing key thermo-hydraulic behaviors while simplifying steam phase change processes. Implemented in Modelica, the model accurately calculates temperature and pressure distributions along steam pipelines. To improve computational efficiency for district-scale simulations, five model simplifications are introduced: lumped thermo-hydraulic functions, empirical correlations, fluid state approximations, steady-state dynamics and inclusion of flow derivatives. These simplified models achieve 85%-98% accuracy in predicting pressure drop and condensation losses, including dynamic condensate behavior during pipe warm-up—a factor often overlooked in existing models. The models support diverse network configurations, scaling effectively to systems with multiple distribution pipes and connected building loads. Discrete models provide detailed insights but exhibit a cubic increase in simulation time as the network scales by N connected building O(N 2.42 ). In contrast, lumped models simulate 10–28 times faster than discrete, offering quadratic scaling of simulation time O(N 1.73 ). However, they still require 6 times more computation time than a lossless network, highlighting the inherent computational challenges of modeling compressible fluid flow. In conclusion, the steady-state lumped variant, with its near-linear scalability in computational time O(N 1.01 ), emerges as an efficient solution for preliminary design evaluations and extensive parametric studies.

15 GEOTHERMAL ENERGY↗

Achieving Energy Efficiency In Small Businesses In Low-Income Areas

Lime Energy, with funding from the Department of Energy’s Office of Energy Efficiency and Renewable Energy (EERE), recently concluded a project demonstrating a new business model for executing energy efficiency for small businesses, in which we aspired to focus on low-income urban areas. As initially conceived, the Project would advance beyond the current best practices used to foster energy efficiency action in small and midsized commercial buildings (under 25,000 square feet), which represent 95% of all commercial customers in the United States. As the project proceeded, Lime Energy discovered that the business model needed to be further refined in areas where Lime already had a presence in the community and the benefit of a relationship with the known utility. The need for this intermediate step – of deploying the business model in an established region – has since been validated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unlocking energy efficiency in small commercial buildings through mechanical contractors

Although buildings smaller than 4,645 m 2 account for nearly half of the energy used in U.S. commercial buildings, energy-efficiency programs to date have primarily focused on larger buildings. Stakeholder interviews conducted during a scoping study by Lawrence Berkeley National Laboratory (LBNL) indicated interest in energy efficiency from the small commercial building sector, provided solutions are simple and of low cost. To address this need, an energy management package (EMP) was developed to deliver energy management to small commercial buildings via HVAC contractors, because they already serve these clients and the transaction cost to market would be reduced. This energy-management approach is unique from, but often complementary to, conventional quality maintenance or retrofit-focused programs targeting the small commercial segment. Furthermore, this paper presents an overview of the EMP, the business model to deliver it, and preliminary demonstration findings from a pilot use of the EMP. Results from the pilot validated that contractors could deliver the EMP in 4–8 h per building per year and that energy savings of 3–5% are feasible through this approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational fluid dynamic modeling to determine the indoor environment of an electron-ion collider service building

The design for the Electron-Ion Collider (EIC) calls for several service buildings that house various power supplies and control electronics for the collider ring itself. In order to operate within specified conditions, the ambient air entering the power supplies needs to be within a certain temperature range while dissipating the heat from losses. Proper cooling is therefore a necessity in the service buildings to ensure that every aspect of the EIC works as intended. Since the EIC is in the design stage, we are evaluating the indoor environment of the service building using the current design specifications. We have researched multiple forms of literature and performed the necessary calculations to compile a list of boundary conditions that accurately represent the situation at hand. We are using computational fluid dynamics modeling to solve the conservation equations for mass, momentum, and energy (Navier-Stokes). This allows us to perform a finite element analysis which will give us the flow distribution in the room as well as temperature profiles throughout the building. We have obtained a simulation result giving us the temperature profiles for the building and it shows that the placement of the racks and supply vents are essential to obtaining an even temperature distribution. This model will provide a basis for design decisions which will affect the overall cooling of the service building without extending the schedule and avoiding a costly reworking of the cooling system.

43 PARTICLE ACCELERATORS↗

Generating synthetic occupants for use in building performance simulation

Occupant behaviour simulation frameworks can employ synthetic populations to characterize occupancy and behavioural patterns in buildings based on observed demographic data at a certain geographical location. For buildings, very few synthetic occupant populations have been generated. This paper uses a Bayesian Networks (BN) structural learning approach to synthesize populations of occupants in a multi-family housing case study. Two additional cases of office occupants and senior housing residents are considered as a cross-case comparison. Furthermore, we draw upon the extended version of drivers-needs-actions-systems (DNAS) framework to guide the selection of variables and data imputation. Our results show that the BN approach is powerful in learning the structure of data sets. The synthetic data sets successfully match the joint distributions of the underlying combined data sets. Experiments on the multi-family housing particularly show better performance than the office and senior housing cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Robust anomaly detection for particle physics using multi-background representation learning

Abstract Anomaly, or out-of-distribution, detection is a promising tool for aiding discoveries of new particles or processes in particle physics. In this work, we identify and address two overlooked opportunities to improve anomaly detection (AD) for high-energy physics. First, rather than train a generative model on the single most dominant background process, we build detection algorithms using representation learning from multiple background types, thus taking advantage of more information to improve estimation of what is relevant for detection. Second, we generalize decorrelation to the multi-background setting, thus directly enforcing a more complete definition of robustness for AD. We demonstrate the benefit of the proposed robust multi-background AD algorithms on a high-dimensional dataset of particle decays at the Large Hadron Collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A machine learning approach to galaxy properties: joint redshift–stellar mass probability distributions with Random Forest

We demonstrate that highly accurate joint redshift–stellar mass probability distribution functions (PDFs) can be obtained using the Random Forest (RF) machine learning (ML) algorithm, even with few photometric bands available. As an example, we use the Dark Energy Survey (DES), combined with the COSMOS2015 catalogue for redshifts and stellar masses. We build two ML models: one containing deep photometry in the griz bands, and the second reflecting the photometric scatter present in the main DES survey, with carefully constructed representative training data in each case. We validate our joint PDFs for 10 699 test galaxies by utilizing the copula probability integral transform and the Kendall distribution function, and their univariate counterparts to validate the marginals. Benchmarked against a basic set-up of the template-fitting code bagpipes, our ML-based method outperforms template fitting on all of our predefined performance metrics. In addition to accuracy, the RF is extremely fast, able to compute joint PDFs for a million galaxies in just under 6 min with consumer computer hardware. Such speed enables PDFs to be derived in real time within analysis codes, solving potential storage issues. As part of this work we have developed galpro 1, a highly intuitive and efficient python package to rapidly generate multivariate PDFs on-the-fly. galpro is documented and available for researchers to use in their cosmology and galaxy evolution studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and Field Testing of Manufacturable Advanced Low-Cost Receiver for Parabolic Trough Solar Power

This project addresses the 30-yr service life, ease of manufacturability for low cost, and low Operations and Maintenance (O&M) costs for our novel parabolic trough receiver, SunTrap. Current trough-based commercial power plants operate at 400°C or below, in part due to poor performance and lifetime of existing receivers at higher temperatures. Thermal losses from such receivers are dominated by radiation; by the Stefan- Boltzmann law, radiative losses have a component that scales as T 4, challenging high-temperature efficiency. Our novel SunTrap receiver offers increased reliability by eliminating the need to operate in a vacuum, while improving performance at higher temperatures by using high-performance insulation on exposed sections of the receiver that absorb negligible solar flux. As a result, SunTrap offers comparable optical efficiency to currently available technology while reducing thermal losses at higher temperatures. In this project, our novel receiver and all subcomponents have been designed to be compatible with molten salts to enable operation at next generation trough-based exit temperatures between 500 and 550°C. Norwich Technologies, with collaborators from Creare, Thermodyne, Solar Dynamics (previously Abengoa Solar), and the University of Louisiana – Lafayette successfully iterated the design of the SunTrap receiver through a series of modelling efforts, cost analyses, prototype builds, and performance and lifetime tests to minimize the levelized cost of energy (LCOE). The final design (1) realized predicted receiver performance in a series of field optical efficiency, laboratory thermal efficiency and freeze/thaw recovery tests, (2) optimized the receiver with respect to integration with standard collector systems, receiver-to-receiver connections, and receiver-to-mirror connections, (3) demonstrated 30-yr service life of receiver and all components of the receiver, (4) developed commercialization and manufacturing plans to enable rapid deployment, and (5) demonstrated durability of an air-stable solar-selective coating. NT’s disruptive technology marshals diverse advances in design, materials and coatings to revolutionize key aspects of the CSP trough solar field. By enabling significant operational and cost advances, this technology offers potential decreases in LCOE of over 20% compared to traditional parabolic trough systems.

14 SOLAR ENERGY↗

BTO Market Success Report 2015–2020

This report highlights 28 BTO-supported, technology-oriented research and development (R&D) projects that resulted in the launch of a commercial product, focusing on identifying new technologies or commercialization updates between 2015 and 2020, where the product remained on the market as of March 2021. The report also includes a listing of the full 45 commercial products supported by BTO as well as a listing of 101 lighting components that benefited from BTO support and were commercialized and integrated into finished lighting products during the same timeframe.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Collaboration for Advanced Modeling of Particle Accelerators

The pverarching purpose is to accelerate and expand the scope of discoveries from high energy physics (HEP) particle accelerators by enabling the design of accelerators that are significantly more compact and cheaper to build and run. This will be realized through (i) developing high-performance computing (HPC) accelerator and beam modeling capabilities to design the full range of systems required (ii) developing community simulation ecosystems that seamlessly integrate accelerator elements to facilitate the design and control of next-generation accelerators.

43 PARTICLE ACCELERATORS↗