Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Build System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Management of Knowledge Representation Standards Activities

Ever since the mid-seventies, researchers have recognized that capturing knowledge is the key to building large and powerful AI systems. In the years since, we have also found that representing knowledge is difficult and time consuming. In spite of the tools developed to help with knowledge acquisition, knowledge base construction remains one of the major costs in building an Al system: For almost every system we build, a new knowledge base must be constructed from scratch. As a result, most systems remain small to medium in size. Even if we build several systems within a general area, such as medicine or electronics diagnosis, significant portions of the domain must be represented for every system we create. The cost of this duplication of effort has been high and will become prohibitive as we attempt to build larger and larger systems. To overcome this barrier we must find ways of preserving existing knowledge bases and of sharing, re-using, and building on them. This report describes the efforts undertaken over the last two years to identify the issues underlying the current difficulties in sharing and reuse, and a community wide initiative to overcome them. First, we discuss four bottlenecks to sharing and reuse, present a vision of a future in which these bottlenecks have been ameliorated, and describe the efforts of the initiative's four working groups to address these bottlenecks. We then address the supporting technology and infrastructure that is critical to enabling the vision of the future. Finally, we consider topics of longer-range interest by reviewing some of the research issues raised by our vision.

Patil, Ramesh S.↗

PoE Lighting System Energy Reporting Study, Part 1

The replacement of today’s lighting infrastructure with LED products offers the potential for future connected lighting systems (CLS) that could become a data-collection platform that enables greater energy savings in buildings and cities. Such connected lighting systems can not only drastically improve the energy performance of lighting and other building systems, but also enable a wide array of services, benefits, and revenue streams that would enhance the value of lighting systems. As LED technology matures, maximizing the energy savings from connected LED lighting systems will become increasingly dependent on successful integration into the built environment. That’s why the DOE SSL Program is working closely with industry to identify and collaboratively address the technology development needs of CLS. For several years now, a growing number of wired and wireless network communication technologies have been integrated into commercially available lighting devices. While most commercially available lighting devices continue to require line-voltage AC power, a few new low-voltage DC technologies have also been introduced into the market as options for powering LED devices. More recently, a technology that has long supported non-lighting applications has become increasingly viable for LED lighting. This approach, whereby a single Ethernet cable is used to both provide low-voltage DC power and enable network communication, is generally referred to as Power over Ethernet (PoE). Whereas wireless solutions offer reduced control system installation cost relative to traditional low-voltage alternatives, PoE technology can offer additional cost savings by transmitting power and communications over the same low-voltage cable, while also reducing demand for wireless bandwidth. Although PoE technology was introduced at the start of this century, it was initially of limited applicability to lighting systems to power transmission limits for available Ethernet cabling. However, PoE has become increasingly viable for lighting applications in recent years as Ethernet cabling technology has evolved and relevant standards and specifications have adapted. These gains have been compounded by ongoing improvements to the luminous efficacy of LED technologies, increasing the number of LED luminaires suitable for use with Ethernet switches capable of sourcing PoE. As a result, a growing number of manufacturers have introduced PoE lighting systems in recent years. Connected lighting systems that can report their own energy consumption can deliver increased energy savings over conventional lighting solutions by facilitating data-driven energy management. PoE technology has the potential to be key in bringing this capability to mainstream lighting applications. This study is the first of a multi-part effort to explore the energy reporting capability of commercially-marketed PoE connected lighting systems. It first provides a brief background on the development of the various PoE technologies, ranging from standards-based to proprietary, and illustrates the convergence of PoE power sourcing capabilities and LED luminaire power requirements. It then classifies PoE system devices in relationship to how they are used in systems—introducing new terminology as needed—and briefly describes different PoE system architectures implemented by various lighting manufacturers. A discussion of existing standards and specifications that address energy reporting is provided, and existing test setups and methods germane to characterizing PoE system energy reporting performance are reviewed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Roof-integrated radiative air-cooling system to achieve cooler attic for building energy saving

The building attic usually subjects to substantial solar heat gain and has much higher temperature compared to the conditioned living space during the day, especially in summer and in hot areas. Reducing attic temperature can reduce cooling energy consumption in buildings. However, conventional techniques such as cool roof or attic ventilation, suffer from either heating penalty in winter or limited attic temperature reduction. In this work, a new roof-integrated radiative air-cooling system is introduced, which couples radiative sky cooling with attic ventilation to reduce attic temperature. A radiative air cooler with 1.08 m 2 surface area is constructed using a recently developed daytime radiative sky cooling metamaterial [Zhai et al., Science 355, pp. 1062–1066, 2017]. Experimental tests show that sub-ambient air cooling is achieved throughout 24-h day-and-night cycle in a summer day with clear sky conditions. Depending on air flow rates, measured sub-ambient temperature reductions of air are 5–8°C at night and 3–5°C at noon under direct sunlight, respectively. An in-house model is first developed for the radiative air-cooling system, the model is then coupled with EnergyPlus to study annual energy saving of buildings. The performance of the radiative air-cooling system is compared with three reference systems: shingle roof, attic ventilation, and cool roof. Results show that for a single-family house, attic temperature can be substantially reduced by 15.5–21.0°C, varying with attic insulation level, compared to shingle roof on typical summer days. Compared to a shingle roof (solar reflectance 0.25, thermal emittance 0.9) residential building with attic insulations of R-30 (RSI-5.28), R-10 (RSI-1.76), and R-0.8 (RSI-0.14), the roof-integrated radiative air-cooling system can achieve annual cooling energy savings of 0.4–1.5 kWh/m 2 (4.6–18.8%), 1.2–3.6 kWh/m 2 (10.2–41.4%), and 3.7–11.8 kWh/m 2 (26.5–76.1%) respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Contributing to Net Zero Building: High Energy Efficient EIFS Wall Systems

The team led by Dow Corning collaborated to increase the thermal performance of exterior insulation and finishing systems (EIFS) to reach R-40 performance meeting the needs for high efficiency insulated walls. Additionally, the project helped remove barriers to using EIFS on retrofit commercial buildings desiring high insulated walls. The three wall systems developed within the scope of this project provide the thermal performance of R-24 to R-40 by incorporating vacuum insulation panels (VIPs) into an expanded polystyrene (EPS) encapsulated vacuum insulated sandwich element (VISE). The VISE was incorporated into an EIFS as pre-engineered insulation boards. The VISE is installed using typical EIFS details and network of trained installers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The economics of solar powered absorption cooling

Analytic procedure evaluates cost of combining absorption-cycle chiller with solar-energy system in residential or commercial application. Procedure assumes that solar-energy system already exists to heat building and that cooling system must be added. Decision is whether to cool building with conventional vapor-compression-cycle chiller or to use solar-energy system to provide heat input to absorption chiller.

Bartlett, J. C.↗

SeeQ: A Programming Model for Portable Data-Driven Building Applications

This paper introduces SeeQ, a programming model and an abstraction framework that facilitates the development of portable data- driven building applications. Data-driven approaches can provide insights into building operations and guide decision-making to achieve operational objectives. Yet the configuration of such applications per building requires extensive effort and tacit knowledge. In SeeQ, we propose a portable programming model and build a software system that enables self-configuration and execution across diverse buildings. The configuration of each building is captured in a unified data model - in this paper, we work with the Brick ontology without loss of generality. SeeQ focuses on the distinction between the application logic and the configuration of an application against building-specific data inputs and systems. We test the proposed approach by configuring and deploying a diverse range of applications across five heterogeneous real-world buildings. The analysis shows the potential of SeeQ to significantly reduce the efforts associated with the delivery of building analytics.

analytics↗

Goode Gym Energy Renovation Project

The Ida H. Goode Gymnasium was constructed in 1964 to serve as a focal point for academics, student recreation, and health and wellness activities. This 38,000 SF building contains a gymnasium with a stage, swimming pool, eight classrooms, a weight room, six offices and auxiliary spaces for the athletic programs. The gym is located on a 4-acre greenfield, which is slated for improvement and enhancement to future athletics program at Bennett College. The available funding for this project was used to weatherize the envelope of the gymnasium, installation of a new energy-efficient mechanical system, and a retrofit of the existing lighting systems in the building’s interior. The envelope weatherization was completed without disturbing the building’s historic preservation eligibility. The existing heating system was replaced with a new high efficiency condensing system. The new heating system also includes a new Building Automation System which provides additional monitoring. Proper usage of this system will provide additional energy savings. Most of the existing interior lighting fixtures and bulbs were replaced with new LED and high efficiency T-8 bulbs and fixtures. Occupancy sensors were installed in applicable areas. The Ida Goode Gymnasium should experience high electricity and natural gas savings as well as operational/maintenance efficiency increases. The aesthetics of the building was maintained and the overall safety was improved.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupling indoor airflow, HVAC, control and building envelope heat transfer in the Modelica Buildings library

Here, this paper describes a coupled dynamic simulation of an indoor environment with heating, ventilation, and air conditioning (HVAC) systems, controls and building envelope heat transfer. The coupled simulation can be used for the design and control of ventilation systems with stratified air distributions. Those systems are commonly used to reduce building energy consumption while improving the indoor environment quality. The indoor environment was simulated using the fast fluid dynamics (FFD) simulation programme. The building fabric heat transfer, HVAC and control system were modelled using the Modelica Buildings library. After presenting the concept, the mathematical algorithm and the implementation of the coupled simulation were introduced. The coupled FFD–Modelica simulation was then evaluated using three examples of room ventilation with complex flow distributions with and without feedback control. Lastly, further research and development needs were also discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unique Building Identifier Generator

We developed a grid reference system-based Unique Building Identifier (UBID). The method converts a building footprint on a map to a unique code. Unlike geographic coordinates (latitude and longitude), which require high precision and can only locate points on the earth, the UBID code records two-dimensional information about a building footprint in a concise and practical manner. The UBID itself is neither a database nor a data schema. Rather, it acts as an external common key between databases to facilitate data mapping. The developed ruleset ensures that individual implementers can reach the same conclusion utilizing publicly available digital maps. It can also automatically resolve discrepancies, caused by physical space or structure changes over time, during data exchange. The method is also flexible and scalable to identify a portion of a building or a group of buildings.

Vlachokostas, EfthimiosAlex↗

Control and Management of Multiple Converters in a Residential Smart Grid

Power electronic systems are becoming a staple building block for electric grid networks. However, these systems have been largely designed to grid integrate in ad hoc configurations with little or no coordination of control. This work proposes a central controller and power electronic system hardware and software design for a residential system (photovoltaic, energy storage and residential building). This system supports auto-integration, plug and play capabilities, and optimal energy management to meet different use cases. Modelling and multi-day testing of the system have been conducted in a controller hardware-in-the-loop (C-HIL) testbed. Multiple use cases and pricing options have been considered as part of the simulation and testing. Results are presented of these systems as a proof of principle.

Starke, Michael↗

Building America Case Study: High-Velocity Small-Diameter Duct System, Pittsburgh, Pennsylvania

This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measure of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.

Building America↗

Energy Savings Potential and Research, Development, & Demonstration Opportunities for Residential Building Heating, Ventilation, and Air Conditioning Systems

This report is an assessment of 135 different heating, ventilation, and air-conditioning (HVAC) technologies for U.S. residential buildings to identify and provide analysis on 19 priority technology options in various stages of development. The analyses include an estimation of technical energy-savings potential, descriptions of technical maturity, descriptions of non-energy benefits, descriptions of current barriers for market adoption, and descriptions of the technology's applicability to different building or HVAC equipment types. From these technology descriptions, are suggestions for potential research, development and demonstration (RD&D) initiatives that would support further development of the priority technology options.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fungal colonization of fiberglass insulation in the air distribution system of a multi-story office building: VOC production and possible relationship to a sick building syndrome

Complaints characteristic of those for sick building syndrome prompted mycological investigations of a modern multi-story office building on the Gulf coast in the Southeastern United States (Houston-Galveston area). The air handling units and fiberglass duct liner of the heating, ventilating and air conditioning system of the building, without a history of catastrophic or chronic water damage, demonstrated extensive colonization with Penicillium spp and Cladosporium herbarum. Although dense fungal growth was observed on surfaces within the heating-cooling system, most air samples yielded fewer than 200 CFU m-3. Several volatile compounds found in the building air were released also from colonized fiberglass. Removal of colonized insulation from the floor receiving the majority of complaints of mouldy air and continuous operation of the units supplying this floor resulted in a reduction in the number of complaints.

NASA Program Environmental Health↗

Large Language Models for the Creation and Use of Semantic Ontologies in Buildings: Requirements and Challenges

Semantic ontologies offer a formalized, machine-readable framework for representing knowledge, enabling the structured description of complex systems. In the building domain, the adoption of ontologies like the Brick schema has transformed how buildings and their systems are modeled by providing a standardized, interoperable language. However, the complexity and the steep learning curve involved in developing and querying semantic models present substantial challenges, often requiring a workforce with specialized expertise. This paper builds on our experience in investigating how Large Language Models (LLMs) can help address these challenges, focusing on their role in constructing and querying of semantic models, particularly using the Brick Schema. Our study outlines the requirements and metrics for evaluating the scalability and effectiveness of LLM-based tools, while also discussing the current challenges and limitations in developing such tools. Ultimately, this paper aims to orient research efforts as various groups experiment with diverse techniques, while enabling more effective comparison of emerging solutions and fostering collaboration across the field.

Mulayim, Ozan Baris↗

Solar heating system installed at Blakedale Professional Center, Greenwood, South Carolina

Information on the solar heating system installed at the Blakedale Professional Center, in Greenwood, South Carolina is presented. The information consists of site and building description, solar system description, performance evaluation, system problems and installation drawings. The solar system was designed to provide approximately 85 percent of the building's heating requirements. The system was installed concurrently with building construction and heats 4,440 square feet of the building. There are 954 square feet of liquid flat plate collectors that are proof-mounted and have a drain-down system to protect the collectors from freezing. A 5,000 gallon steel, polyurethane insulated tank buried underground provides storage. The system was fully instrumented for performance evaluation and integrated into the National Solar Data Network.

Source record↗

A review of the technology of noncontacting systems

Advanced components are the fundamental building blocks of advanced systems and spacecraft. Non-contacting elements, including magnetic bearings, brushless and ironless armature motors, rotary transformers and encoders, are discussed. Most of the information presented in this paper has been generated from a continuing program of component development. The aim of this paper is to identify some of the important design features and provide a perspective on the state of development reached to date.

Studer, P. A.↗

Using Rollback Avoidance to Mitigate Failures in Next-Generation Extreme-Scale Systems

High-performance computing (HPC) systems enable scientists to numerically model complex phenomena in many important physical systems. The next major milestone in the development of HPC systems is the construction of the rst supercomputer capable executing more than an exa op, 10 18 oating point operations per second. On systems of this scale, failures will occur much more frequently than on current systems. As a result, resilience is a key obstacle to building next-generation extremescale systems. Coordinated checkpointing is currently the most widely-used mechanism for handling failures on HPC systems. Although coordinated checkpointing remains e ective on current systems, increasing the scale of today's systems to build next-generation systems will increase the cost of fault tolerance as more and more time is taken away from the application to protect against or recover from failure. Rollback avoidance techniques seek to mitigate the cost of checkpoint/restart by allowing an application to continue its execution rather than rolling back to an earlier checkpoint when failures occur. These techniqes include failure prediction and preventive migration, replicated computation, fault-tolerant algorithms, and softwarebased memory fault correction. In this thesis, we examine how rollback avoidance techniques can be used to address failures on extreme-scale systems. Using a combination of analytic modeling and simulation, we evaluate the potential impact of rollback avoidance on these systems. We then present a novel rollback avoidance technique that exploits similarities in application memory. Finally, we examine the feasibility of using this technique to protect against memory faults in kernel memory.

97 MATHEMATICS AND COMPUTING↗

Observed Faraday Effects in Damped Lyα Absorbers and Lyman Limit Systems: The Magnetized Environment of Galactic Building Blocks at Redshift = 2

Protogalactic environments are typically identified using quasar absorption lines and can manifest as Damped Lyman-alpha Absorbers (DLAs) and Lyman Limit Systems (LLSs). We use radio observations of Faraday effects to test whether these galactic building blocks host a magnetized medium, by combining DLA and LLS detections with 1.4 GHz polarization data from the NRAO VLA Sky Survey (NVSS). We obtain a control, a DLA, and an LLS sample consisting of 114, 19, and 27 lines of sight, respectively. Using a Bayesian framework and weakly informative priors, we are unable to detect either coherent or random magnetic fields in DLAs: the regular coherent fields must be ⩽2.8 μG, and the lack of depolarization suggests the weakly magnetized gas in DLAs is non-turbulent and quiescent. However, we find a mild suggestive indication that LLSs have coherent magnetic fields, with a 71.5% probability that LLSs have higher |RM| than a control, although this is sensitive to the redshift distribution. We also find a strong indication that LLSs host random magnetic fields, with a 95.5% probability that LLS lines of sight have lower polarized fractions than a control. The regular coherent fields within the LLSs must be ⩽2.4 μG, and the magnetized gas must be highly turbulent with a typical turbulent length scale on the order of ≈5–20 pc. Our results are consistent with the standard dynamo paradigm, whereby magnetism in protogalaxies increases in coherence over cosmic time, and with a hierarchical galaxy formation scenario, with the DLAs and LLSs exploring different stages of magnetic field evolution in galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗