Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Magnetohydrodynamics and Heat Transfer in a Free-Surface, Flowing Liquid Metal Experiment

This thesis examines magnetohydrodynamic (MHD) effects and heat transfer in free-surface, liquid metal flow. The interaction of the flow with the applied magnetic field introduces an anisotropy to the fluid motion, resulting in starkly different behavior depending on the orientation and strength of the applied magnetic field. The transition from a hydrodynamic state to an MHD state was experimentally found to be characterized by the interaction parameter, N = &sigma L B 2 /&rho v0 , crossing above 0.5. The experiment consisted of a channel 1 m in length, up to 16 cm in width and 1 to 2.5 cm in depth situated within an electromagnet capable of producing a uniform magnetic field up to 2.7 kG. The fluid velocity was measured with an array of 25 potential probes that resolved the spanwise velocity profile, while waves on the surface of the metal were monitored via a diagnostic that tracked the motion of a laser beam reflected off of the free surface. Lastly, the temperature response of the fluid was recorded with an array of 32 thermocouples embedded in the bottom of the channel and a mid-wavelength infrared camera used to image the free surface. Three distinct sets of experiments were performed to investigate the effects of the applied magnetic field on the dynamics within the flow, studying: 1) changes to vortices in the wake of a cylinder, 2) behavior of surface fluctuations due to the turbulent flow, and 3) vertical heat transfer resulting from heat deposition on the free surface. The first set of experiments examined the wake of a cylinder inserted into the flow with its axis parallel to the magnetic field. Measurements with the potential probes indicated that vortices in the wake became laminarized as the field was increased due to the alignment of the injected vorticity with the applied field. The second set of experiments showed that surface fluctuations were suppressed at high magnetic fields, but the precise nature of the damping depended on the orientation of the applied field. Lastly, when heat was injected at the free surface via a resistive heater, the temperature response of the fluid was found to vary considerably depending on the strength and direction of the applied field. In all experiments, it was observed that the angle between the vorticity of structures in the flow and the applied magnetic field dictated the macroscopic behavior of the fluid. This work provides the first experimental results of several phenomena associated with free-surface, liquid metal flows in an applied magnetic field. Further, the results have direct implications for proposed flowing liquid metal divertors for fusion reactors, and offer insight into the nature of turbulent MHD flows.

fusion↗

A RHIC-style IPM in the Brookhaven AGS

Beam profiles in the two storage rings of the Relativistic Heavy-Ion Collider (RHIC) at Brookhaven National Lab (BNL) are measured with ionization profile monitors (IPMs). Each ring has a vertical and horizontal detector. An IPM measures the distribution of electrons produced in the beam line by beam ionization of background gas. These detectors have been developed at BNL in a program that began in 1996. The current detectors are a design that was based on a prototype built in 2007 and used in RHIC from 2007 to 2012. During the 2012 shutdown we refurbished this prototype and installed it into the Alternating-Gradient Synchrotron (AGS). This paper describes the new AGS IPM and shows data from the detector commissioning.

43 PARTICLE ACCELERATORS↗

Production of Samples of Individual Radioxenon Isotopes Through Neutron Irradiation of Stable Xenon Gas

The Spectral Deconvolution Analysis Tool (SDAT) software was developed to improve counting statistics and detection limits for nuclear explosion radionuclide measurements. SDAT utilizes spectral deconvolution spectroscopy techniques and can analyze both β-γ coincidence spectra for radioxenon isotopes and high-resolution HPGe spectra from aerosol monitors. The deconvolution algorithm of the SDAT requires a library of β-γ coincidence spectra of individual radioxenon isotopes to determine isotopic ratios in a sample. In order to get experimentally produced spectra of the individual isotopes we have irradiated enriched samples of 130Xe, 132Xe, and 134Xe gas with a neutron beam from the TRIGA reactor at The University of Texas. The samples produced were counted in an Automated Radioxenon Sampler/Analyzer (ARSA) style β-γ coincidence detector. The spectra produced show that this method of radioxenon production yields samples with very high purity of the individual isotopes for 131mXe and 135Xe and a sample with a substantial 133mXe to 133Xe ratio.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

SU-E-T-495: Influence of Reduced Target-To-Nozzle Distance On Secondary Neutron Dose Equivalent in Proton and Carbon Ion Radiotherapy

Purpose: Ion beams have an unavoidable lateral spread due to nuclear interactions interacting with the air and monitoring systems. To minimize this spread, the distance between the nozzle and the patient should be kept as small as possible.The purpose of this work was to determine the impact of the target-to-nozzle distance reduction on the secondary neutron dose equivalent in proton and carbon ion radiotherapy. Methods: In this study, abdominal and head phantoms were scanned with our CT scanner. Cubical targets with side lengths of 3 cm to 10 cm and 1 cm to 5 cm were drawn in the abdominal and head phantoms respectively. Two intensity-modulated plans were made for each phantom and ion. The first of these plans placed the target at the isocenter while the other shifted the phantom 30 cm towards the nozzle. The plans at both phantom locations were optimized to provide identical dose coverage to the PTVs.Secondary neutron dose equivalent at 50 cm lateral to the center of target. Results: The neutron dose equivalent was higher for the larger field size from 0.25µSv per Gy (RBE) to 72µSv per Gy (RBE). The neutron dose equivalent was smaller when the phantom was placed at the upstream target location versus at the isocenter location by 8.9% to 10.4% and 11.0% to 22.1% for proton plans of the abdominal and head phantoms respectively. Differences for carbon plans with different target-to-nozzle locations were less than 3% for both phantoms. Conclusion: A reduction of target-to-nozzle distance can lead to benefits for proton radiotherapy. In this study, a reduction of secondary neutron dose equivalent was found for proton plans with a smaller target-to-nozzle distance. A greater impact was found for a head phantom with a smaller field size; however, a reduction of the target-to-nozzle distance had little effect for carbon therapy.

60 APPLIED LIFE SCIENCES↗

Dynamic measurements and simulations of airborne picolitre-droplet coalescence in holographic optical tweezers

We report studies of the coalescence of pairs of picolitre aerosol droplets manipulated with holographic optical tweezers, probing the shape relaxation dynamics following coalescence by simultaneously monitoring the intensity of elastic backscattered light (EBL) from the trapping laser beam (time resolution on the order of 100 ns) while recording high frame rate camera images (time resolution <10 μs). The goals of this work are to: resolve the dynamics of droplet coalescence in holographic optical traps; assign the origin of key features in the time-dependent EBL intensity; and validate the use of the EBL alone to precisely determine droplet surface tension and viscosity. For low viscosity droplets, two sequential processes are evident: binary coalescence first results from the overlap of the optical traps on the time scale of microseconds followed by the recapture of the composite droplet in an optical trap on the time scale of milliseconds. As droplet viscosity increases, the relaxation in droplet shape eventually occurs on the same time scale as recapture, resulting in a convoluted evolution of the EBL intensity that inhibits quantitative determination of the relaxation time scale. Droplet coalescence was simulated using a computational framework to validate both experimental approaches. The results indicate that time-dependent monitoring of droplet shape from the EBL intensity allows for robust determination of properties such as surface tension and viscosity. Finally, the potential of high frame rate imaging to examine the coalescence of dissimilar viscosity droplets is discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The NSTX fast-ion D-alpha diagnostic

A new diagnostic, aimed at energy-resolved measurements of the spatial and temporal dynamics of fast ions in NSTX plasmas, is described. It is based on active charge-exchange recombination spectroscopy. The fast-ion signal is inferred from light emitted in the wavelength range of the D{sub {alpha}} line by fast ions recombining with an injected neutral beam. Two complementary systems are operational. The first system, based on a spectrometer coupled to a charge coupled device detector, has 16 channels with space, time, and energy resolution of 5 cm, 10 ms, and 10 keV, respectively. The second system monitors the energy-integrated fast-ion signal on time scales of {approx}20 {mu}s at three different radii. Signals are measured by a multianode photomultiplier tube. For both systems, each channel includes two paired views, intercepting and missing the neutral beam for a direct subtraction of the background signal not associated with fast ions. Examples of signals from the 2008 NSTX run are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

2012 Ground Testing Highlights

As part of the Fundamental Aeronautics Program and a collaborative effort with Boeing, and Lockheed Martin this past year a series of sonic boom test were completed in the NASA Ames Unitary Plan Wind Tunnel (UPWT). One of the goals was to develop new test techniques and hardware for measuring sonic boom signatures in the transonic and supersonic regimes. Data for various model designs and configurations were collected and will be used to validate CFD predictions of sonic boom signatures. Reactivation of the NASA Ames Mitsubishi compressor system was completed this past year. The compressor is intended to replace and augment the existing UPWT Clark Compressor as the primary Make Up Air (MUA) source. The MUA system provides air and vacuum pumping capability to the Ames UPWT. It will improve productivity and reliability of the UPWT as a vital testing and research facility for the U.S. aerospace industry and NASA. Funding for this task was provided from the American Recovery Investment Act (ARRA). Installation and validation of a Noncontact Stress Monitoring System (NSMS) for the 3-stage compressor was completed at the 11-foot Transonic Wind Tunnel. The system, originally developed at AEDC, consists of 36 pairs of LED light sources with optic beam send and receive probes along a 1-per rev signal. The new system allows for continuous monitoring and recording of compressor blade bending and torsion stress during normal test operations. A very unusual test was completed in the 11 FT TWT to acquire aerodynamic and flow field data for the Crew Exploration Vehicle (CEV) Parachute Assembly System (CPAS) to validate CFD methods and tools. Surface pressure distribution measurements and velocity measurements in the wake of the command module back to the drogues parachute location were acquired. Testing methods included Particle Image Velocimetry (PIV), Pressure Sensitive Paint (PSP), Schlieren Infrared Imaging (IR) and boundary layer survey and skin friction.

Buchholz, Steven J.↗

Observing the Growth of Metal-Organic Frameworks by In-Situ Liquid Cell Transmission Electron Microscopy

Liquid Cell Transmission Electron Microscopy (LCTEM) can provide direct observations of solution phase nanoscale materials, and holds great promise as a tool for monitoring dynamic self assembly processes. Control over particle behavior within the liquid cell, and under electron beam irradiation, is of paramount importance for this technique to contribute to our understanding of chemistry and materials science at the nanoscale. However, this type of control has not been demonstrated for complex, organic macromolecular materials, which form the basis for all biological systems, all of polymer science, and encompass important classes of advanced porous materials. Here we show that by controlling the liquid cell surface chemistry and electron beam effects, the dynamics and self-assembly of metal-organic frameworks (MOFs) can be observed. Our results demonstrate that hybrid organic/inorganic beam sensitive materials can be analyzed with LCTEM and at least in the case of Zif-8 dynamics, the results correlate with observations from bulk growth or other standard synthetic conditions. We anticipate that direct, nanoscale imaging by LCTEM of MOF nucleation and growth mechanisms, may provide insight into controlled MOF crystal morphology, domain composition, and processes influencing defect formation.

Environmental Molecular Sciences Laboratory↗

Wireless and chip-less passive radiation sensors for high dose monitoring

The safety of nuclear infrastructures may involve the monitoring of many parameters in harsh environments (high radiation level, high temperature, high pressure,..). If technological solutions exist for transducers part in such environments, the electronic part used in reader is not appropriate and still a challenging task. Well-known solutions to remove the electronic part from the harsh environment consist of connecting the transducer and the reader by long electrical wires or performing ex situ remote sensing. However wires may practically be difficult to implement while ex situ measurements are not compatible with on line monitoring. Wireless and passive sensors working in harsh environments could be an appropriate solution for the remote sensing of critical parameters. Passive sensors without electronics in the sensing unit are available (e.g., SAW sensors) but they suffer from short reading range (typically lower than 10 meters). In order to overcome this range limitation a new class of electromagnetic transducers was developed in the mid-2000's. The operating principle is based on the modification of the properties of high-frequency (>> 1 GHz) passive electromagnetic devices by the quantity to be measured. Based on this principle a wide range of sensing properties can be addressed and a large number of materials can be chosen. Moreover the use of high frequency allows reducing the size of the sensor elements (antenna, transducer) and enhancing the immunity to multi-path. Several principles of RF transducers have been already validated by LAAS-CNRS (e;g; pressure, temperature, stress) as well as radar-based solution for the wireless long-range sensors interrogation. The sensor dosimeter exploit here the known property of Hydrogen-Pressure Dosimeters (HPD) for which the polymer material dehydrogenates under nuclear irradiation. The transducer principle is described. The irradiation will generate the out-gazing (hydrogen) of the polymer inside a micro-chamber. The resulting overpressure leads to the deflection of a silicon membrane which modifies the resonant frequency of the RF resonator. Tests structures have been designed in order to quantify the HDPE out-gazing inside a micro-cavity by measuring the deflection of a boss silicon membrane with a mechanical profiler. A specific set up using interferometry method has been also developed to evaluate the pressure generated inside the micro-cavity. The procedure consists in applying a pressure that pushes the membrane to recover a flat membrane. This condition is monitored thanks to the extinction of the Newton rings. Irradiations have been performed up to 30 kGy using 6 MeV focused e-beam providing by electron accelerator. Membrane deflection and generated pressure around 0.2 μm/mg{sub HDPE}/kGy and 70 mbar/mg{sub HDPE}/kGy has been obtained for a 70 μm thick membrane. In order to characterize the hermetic sealing of the micro-chamber under hydrogen over-pressure, membrane deflection after irradiation has been recorded during 50 days. The variations of membrane deflection are randomly distributed and generally lower than ±5%, showing a good hermeticity during this period. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Bunch Integrators at Fermilab During Run II

The Fast Bunch Integrator is a bunch intensity monitor designed around the measurements made from Resistive Wall Current Monitors. During the Run II period these were used in both Tevatron and Main Injector for single and multiple bunch intensity measurements. This paper presents an overview of the design and use of these systems during this period. During the Run II era the Fast Bunch integrators have found a multitude of uses. From antiproton transfers to muti-bunch beam coalescing, Main Injector transfers to halo scraping and lifetime measurements, the Fast Bunch Integrators have proved invaluable in the creation and maintenance of Colliding Beams stores at Fermilab.

43 PARTICLE ACCELERATORS↗

Lamb Wave Assessment of Fatigue and Thermal Damage in Composites

Among the various techniques available, ultrasonic Lamb waves offer a convenient method of evaluating composite materials. Since the Lamb wave velocity depends on the elastic properties of a structure, an effective tool exists to monitor damage in composites by measuring the velocity of these waves. Lamb wave measurements can propagate over long distances and are sensitive to the desired in-plane elastic properties of the material. This paper describes two studies which monitor fatigue damage and two studies which monitor thermal damage in composites using Lamb waves. In the fatigue studies, the Lamb wave velocity is compared to modulus measurements obtained using strain gage measurements in the first experiment and the velocity is monitored along with the crack density in the second. In the thermal damage studies, one examines samples which were exposed to varying temperatures for a three minute duration and the second includes rapid thermal damage in composites by intense laser beams. In all studies, the Lamb wave velocity is demonstrated to be an excellent method to monitor damage in composites.

Seale, Michael D.↗

Monte Carlo simulator of realistic x-ray beam for diagnostic applications

Purpose: Monte Carlo simulation is a very useful tool for radiotherapy and diagnostic radiology. Yet even with the latest PCs, simulation of photon spectra emitted by an x-ray tube is a time-consuming task, potentially reducing the possibility to obtain relevant data such as dose evaluations, simulation of geometric settings, or monitor detector efficiency. This study developed and validated a method to generate random numbers for realistic beams in terms of photon spectrum and intensity to simulate x-ray tubes via Monte Carlo algorithms. Methods: Starting from literature data, the most common semiempirical models of bremsstrahlung are analyzed and implemented, adjusting their formulation to describe a large irradiation area (i.e., large field of view) and to take account of the heel effect as in common practice during patient examinations. Results: Simulation results show that Birch and Marshall's model is the fastest and most accurate for the aims of this work. Correction of the geometric size of the beam and validation of the intensity variation (heel effect) yielded excellent results with differences between experimental and simulated data of less than 6%. Conclusions: The results of validation and execution time showed that the tube simulator calculates the x-ray photons quickly and efficiently and is perfectly capable of considering all the phenomena occurring in a real beam (total filtration, focal spot size, and heel effect), so it can be used in a wide range of applications such as industry, medical physics, or quality assurance.

60 APPLIED LIFE SCIENCES↗

TU-D-209-06: Head and Neck Tissue Dose From X-Ray Scatter to Physicians Performing Cardiovascular Procedures

Purpose: The purpose of this work was to characterize the spatial distribution of scatter radiation to the head and neck of a physician performing an x-ray interventional procedure and assess brain, eye lens, and carotid artery dose. Methods: Radiographic x-ray beams were tuned to match the peak energy (56 to 106 keV) and HVL (3.5 to 6.5 mm Al) of x-ray scatter originating from a patient during a fluoroscopic procedure. The radiographic beam was directed upon a Rando phantom from an inferior-left location to mimic a typical patient-operator geometric relationship. A lead-equivalent protective garment was secured to the phantom. Direct exposure Gafchromic film (XRQA2) was placed between the transverse plane layers of the head and neck region of the phantom and exposed with 4 scatter-equivalent radiographic beams. A 3×3 cm{sup 2} film placed at the left collar of the phantom was used to monitor incident dose in the position of a radiation monitoring badge. The films were converted to 2D dose distribution maps using FilmQA Pro software and an Epson 11000-XL scanner. The 2D dose distributions maps were normalized by the left collar dose and the percent of left collar dose (%LCD) was calculated for select tissues. Results: The dose maps had high dynamic range (10{sub 4}) and spatial detail. Considering all transverse planes and 4 scatter beam qualities, the median %LCD values were: whole brain 8.5%, left brain 13%, right brain 5.4%, left eye lens 67%, right eye lens 25%, left carotid artery 72%, and right carotid artery 28%. Conclusion: Scatter radiation dose to an operator can be simulated using a tuned radiographic beam and used to expose a phantom and Gafchromic film, thereby creating detailed 2D dose distribution maps. This work facilitates individualized estimation of dose to select head and neck tissues based on an operator’s radiation monitoring badge value.

60 APPLIED LIFE SCIENCES↗

Hamamatsu PMT R7056 Study for the Extinction Monitoring System of the Mu2e Experiment at Fermilab

The Mu2e experiment at Fermilab proposes to search for the coherent neutrino-less conversion of muons to electrons in the presence of a nucleus. The experimental signature for an aluminum target is an isolated 105 MeV electron exiting the stopping target no earlier than ~700 ns after the pulse of proton beam hits the production target. Any protons that hit the production target in between the pulses can lead to fake conversion electrons during the measurement period. We define the beam extinction as the ratio of the number of protons striking the production target between pulses to the number striking the target during the pulses. It has been established that an extinction of about 10-10 is required to reduce the backgrounds to an acceptable level. It would be desirable to measure the extinction of the beam coming out of the accelerator in a minute or less. Studies for the fast extinction monitor based on Hamamatsu PMT R7056 is the subject of this publication.

43 PARTICLE ACCELERATORS↗

SU-E-T-618: Dosimetric Comparison of Manual and Beam Angle Optimization of Gantry Angles in IMRT for Cervical Cancer

Purpose: To evaluate the dosimetric characteristics of intensity-modulated radiotherapy (IMRT) treatment plan with beam angle optimization. Methods: Ten post-operation patients with cervical cancer were included in this analysis. Two IMRT plans using seven beams were designed in each patient. A standard coplanar equi-space beam angles were used in the first plan (plan 1), whereas the selection of beam angle was optimized by beam angle optimization algorithm in Varian Eclipse treatment planning system for the same number of beams in the second plan (plan 2). Two plans were designed for each patient with the same dose-volume constraints and prescription dose. All plans were normalized to the mean dose to PTV. The dose distribution in the target, the dose to the organs at risk and total MU were compared. Results: For conformity and homogeneity in PTV, no statistically differences were observed in the two plans. For the mean dose in bladder, plan 2 were significantly lower than plan 1(p<0.05). No statistically significant differences were observed between two plans for the mean doses in rectum, left and right femur heads. Compared with plan1, the average monitor units reduced 16% in plan 2. Conclusion: The IMRT plan based on beam angle optimization for cervical cancer could reduce the dose delivered to bladder and also reduce MU. Therefore there were some dosimetric advantages in the IMRT plan with beam angle optimization for cervical cancer.

60 APPLIED LIFE SCIENCES↗

Dosimetric Comparison of 6 MV and 15 MV Single Arc Rapidarc to Helical TomoTherapy for the Treatment of Pancreatic Cancer

We conducted a planning study to compare Varian's RapidArc (RA) and helical TomoTherapy (HT) for the treatment of pancreatic cancer. Three intensity-modulated radiotherapy (IMRT) plans were generated for 8 patients with pancreatic cancer: one using HT with 6-MV beam (Plan{sub HT6}), one using single-arc RA with 6-MV beam (Plan{sub RA6}), and one using single-arc RA with 15-MV beam (Plan{sub RA15}). Dosimetric indices including high/low conformality index (CI{sub 100%}/CI{sub 50%}), heterogeneity index (HI), monitor units (MUs), and doses to organs at risk (OARs) were compared. The mean CI{sub 100%} was statistically equivalent with respect to the 2 treatment techniques, as well as beam energy (0.99, 1.01, and 1.02 for Plan{sub HT6}, Plan{sub RA6}, and Plan{sub RA156,} respectively). The CI{sub 50%} and HI were improved in both RA plans over the HT plan. The RA plans significantly reduced MU (MU{sub RA6} = 697, MU{sub RA15} = 548) compared with HT (MU{sub HT6} = 6177, p = 0.008 in both cases). The mean maximum cord dose was decreased from 29.6 Gy in Plan{sub HT6} to 21.6 Gy (p = 0.05) in Plan{sub RA6} and 21.7 Gy (p = 0.04) in Plan{sub RA15}. The mean bowel dose decreased from 17.2 Gy in Plan{sub HT6} to 15.2 Gy (p = 0.03) in Plan{sub RA6} and 15.0 Gy (p = 0.03) Plan{sub RA15}. The mean liver dose decreased from 8.4 Gy in Plan{sub HT6} to 6.3 Gy (p = 0.04) in Plan{sub RA6} and 6.2 Gy in Plan{sub RA15}. Variations of the mean dose to the duodenum, kidneys, and stomach were statistically insignificant. RA and HT can both deliver conformal dose distributions to target volumes while limiting the dose to surrounding OARs in the treatment of pancreatic cancer. Dosimetric advantages might be gained by using RA over HT by reducing the dose to OARs and total MUs used for treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Simultaneous Temperature/Pressure Monitoring in Compressible Flows using Hybrid fs/ps Pure-Rotational CARS

We demonstrate simultaneous monitoring of temperature and pressure using a hybrid femtosecond/picosecond pure-rotational CARS technique in a one-dimensional line-imaging configuration. The method employs two detection channels and two 60-ps-duration probe laser beams with independently adjustable time delays from the broadband 35-fs pump/Stokes pulse. Simultaneous temperature and pressure monitoring is demonstrated along the centerline of a canonical under expanded compressible air jet flow emanating from a choked, sonic nozzle. Temperature is measured almost independently of pressure by analyzing CARS spectra obtained with a probe pulse near zero time delay for nearly collision-free acquisition. Pressure is obtained from spectra acquired with long probe time delays to sample the impact of gas-phase collisions. The CARS measurements were obtained in both time-averaged and single-laser-shot mode with 67 μm spatial resolution along the jet axis along a nominally 6-mm line. The measurements span a temperature and pressure range of T= 70-300 K and P= 0.05-1.2atm.

Sean P Kearney↗