Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Analytical Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Development of MCNP Training Modules for Safeguards Practitioners [Abstract]

The Monte-Carlo N-Particle (MCNP) software developed at LANL is the most widely used neutron transport code in the world. It is an essential tool for a variety of applications including detector development and design, nuclear fuel burnup simulation, criticality safety, and nondestructive assay system optimization. For this reason, it is indispensable within the safeguards and materials control & accountability (MC&A) communities. Multiple MCNP training courses have been created and taught over the last several decades by the MCNP development team at LANL, however there are no existing courses that cover specialized topics considered fundamental to NDA and safeguards models. To fill this gap, the MCNP team and Safeguards Science and Technology group at LANL have co-created a set of training modules customized to meet the specialized needs of the safeguards and MC&A communities. The basic modules cover concepts such as NDA system optimization, He-specific and other capture tallies, and tools for improved theoretical understanding. An advanced module was also created to cover topics including variance reduction for active interrogation simulations, use of the LANL MCNPTools post-processor, PTRAC (particle tracking) and list-mode data simulations, and fuel burnup simulations. The training modules teach to the latest and most state-of-the-art MCNP features and tools released by the development team at LANL and are intended to be taught jointly by the developers and safeguards experts. Ultimately, we hope that creation of these modules will serve to capture and convey the safeguards modeling and MCNP expertise at LANL, and that we will be able to share the modules more broadly with the MC&A and safeguards communities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verification and Validation of the New MCNP6.3 Criticality Features

The MCNP6® code, version 6.3, has been extensively verified and validated for many applications. The use of the same default capabilities existing in the MCNP6.2 code are also used in the verification and validation (V&V) of the MCNP6.3 code. In this paper, selected new features, code enhancements, and bug fixes in the MCNP6.3 code that impact criticality safety applications are described and investigated. More specifically, the changes within the MCNP6.3 code that are studied in this work include both the new fission matrix and the Doppler broadening resonance correction (DBRC) features. For nuclear criticality safety applications, the V&V benchmark problems within the criticality, extended criticality, and Rossi-α suites are used to study the upgrades within the MCNP6.3 code. Some additional investigations into benchmarks at elevated temperatures are used to showcase the impacts of the temperature-specific capabilities.

97 MATHEMATICS AND COMPUTING↗

Verification and Performance Impact of the New Parallel MCNP6.3 Particle Track Output Capability for Subcritical Multiplication Simulations

The MCNP6® code, version 6.3, has several new features that are intended to ultimately replace legacy features that are now marked for deprecation. One of these features is the new particle track output (PTRAC) format and capability, where the legacy PTRAC capability still exists alongside the modern PTRAC capability in MCNP6.3. While the MCNP6.3 code has been extensively verified and validated for many applications, the PTRAC feature is not exercised in any of the typical verification and validation (V&V) applications studied during the course of a typical MCNP code release. The primary goal of this paper is to verify that the legacy and modern PTRAC feature produces equivalent results for subcritical multiplication benchmarks previously studied. In the process of verifying that the simulated benchmark results are equivalent, the computational performance is compared between the legacy and modern PTRAC uses. In addition to verification of the update, which is important to the community as a whole, this effort also supports advances in the simulation of recent subcritical neutron noise measurements that require higher computational effort per second of real-time measurement than that of systems typically measured.

97 MATHEMATICS AND COMPUTING↗

Analysis of Alternatives for Dismantling of the Equipment in Building 117/1 at Ignalina NPP - 13278

Ignalina NPP was operating two RBMK-1500 reactors which are under decommissioning now. In this paper dismantling alternatives of the equipment in Building 117/1 are analyzed. After situation analysis and collection of the primary information related to components' physical and radiological characteristics, location and other data, two different alternatives for dismantling of the equipment are formulated - the first (A1), when major components (vessels and pipes of Emergency Core Cooling System - ECCS) are segmented/halved in situ using flame cutting (oxy-acetylene) and the second one (A2), when these components are segmented/halved at the workshop using CAMC (Contact Arc Metal Cutting) technique. To select the preferable alternative MCDA method - AHP (Analytic Hierarchy Process) is applied. Hierarchical list of decision criteria, necessary for assessment of alternatives performance, are formulated. Quantitative decision criteria values for these alternatives are calculated using software DECRAD, which was developed by Lithuanian Energy Institute Nuclear engineering laboratory. While qualitative decision criteria are evaluated using expert judgment. Analysis results show that alternative A1 is better than alternative A2. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Coupling Big Data Analytics and Reactive Transport Modeling for Cost-effective Groundwater Monitoring - 17163

This study presents an innovative approach for sustainable and cost-effective groundwater monitoring. This approach takes advantage of recent advances in various technologies: (1) in situ autonomous sensors, (2) big data analytics, and (3) parallel high-performance computing for flow and reactive transport modeling. In situ sensors are used to periodically measure the key variables (such as pH, redox potential, electrical conductivity, and groundwater level), which control contaminant mobility and the plume spatial and temporal distribution. Based on a limited number of groundwater sampling, the data analytics methods-data mining and machine learning-allow us to identify and quantify the correlations between the in situ-measured variables and contaminant concentrations, and also to detect significant changes associated with the plume mobility. In addition, a state-of-the-art parallel numerical flow and reactive transport simulator Amanzi, and uncertainty quantification software Agni are used to provide an improved physical and mechanistic understanding of the contaminated groundwater system behavior, and to predict the long-term plume distribution for optimizing and adapting the monitoring strategy. Amanzi and Agni were developed as part of the Advanced Simulation Capability for Environmental Management (ASCEM) program of the DOE Office of Environmental Management. Such modeling is critical, particularly, for assessing the impact of climate change and associated hydrological shifts. The developed approach is expected to significantly reduce the groundwater sampling frequency and associated cost. In addition, the real-time information on plume mobility serves as an early warning system, improving the resiliency of contaminated or potentially contaminated sites. We demonstrate this approach using as an example the Savannah River Site (SRS) F-Area, where groundwater is contaminated by various radionuclides, including uranium, tritium and technetium. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coupling SCALE with DAKOTA for Axial Burnup Profiles Assessment in Burnup Credit

This paper presents a computational study that demonstrates the application of the SCALE code system in conjunction with the Design Analysis Kit for Optimization and Terascale Applications (DAKOTA) for the analysis of key factors influencing the evaluation of burnup credit (BUC) in pressurized water reactors (PWRs). The primary objective of this analysis is to characterize the model by utilizing parameterization, uncertainty quantification, and optimization studies. Using this approach, we can comprehensively assess the system and conduct informed predictive studies. This study highlights the effectiveness of the SCALE code system integrated within the DAKOTA framework in terms of efficiency and capability. With the coupling of the burnup code ORIGAMI with the CSAS or TSUNAMI-3D sequence embedded in a DAKOTA analysis, we can characterize the factors that influence the k eff of PWR 17x17 spent nuclear fuel (SNF) in the GBC-32 computational benchmark cask for the assessment of BUC in criticality safety analysis. The coupling methodology used in this study is not exclusive to BUC analysis. However, the choice to apply this methodology to the BUC problem is particularly significant because of the diverse range of aspects it encompasses in nuclear criticality safety analyses. This problem presents a unique opportunity to explore and address multiple facets of such analyses related to BUC and illustrates the capability of the SCALE code system with DAKOTA. This analysis makes use of historical reference data for the axial burnup profile, where the entire space within the bounds is considered. Both SCALE and DAKOTA are currently integrated in the Nuclear Energy Advanced Modeling Simulation (NEAMS) Workbench code system, which has a user-friendly graphical interface that simplifies the setup of simulations and configuration of input parameters as well as the visualization of simulation results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Low Level Calibration of Liquid Scintillation Counting

Liquid Scintillation Counting (LSC) is an analytical laboratory method that quantifies the concentrations of alpha and beta emitting isotopes. The LSC method can be utilized for the detection of tritium, both environmentally and at nuclear facilities. Most LSC samples are aqueous-based and prepared as a radioactive sample dissolved or suspended in a high efficiency scintillation cocktail that converts radioactive energy into light pulses. When placed in counting vials, the liquid scintillation cocktail allows for optical coupling in which energy is released from the samples radioactive decay, and transferred to the scintillator. That energy is then absorbed to produce excited electrons that fall back to their ground-state and emit a pulse of light that is detected by the liquid scintillation analyzers photomultiplier tubes. Quench is a signal attenuation due to physical, chemical, or color interferences. To compensate for quench, quench standards of a known concentration are implemented at increasing increments of quench per vial to create a quench curve. Quench standards can be purchased pre-made or customized from the manufacturer, however, there are several issues that arise from purchasing the pre-made quench standards. The main issues with ordering pre-made quench standards is that they use higher count values, between 30,000 and 250,000 disintegrations per minute (dpm) of tritium per vial and only come in glass vials. Using higher counting standards in glass vials makes it hard to see lower concentrations in plastic vials. Additionally, when using higher energy standards the accuracy of the calibration readings tend to be lower. On the other hand, making a set of quench standards in-house allows for the customization of the dpm concentration to roughly 1,500-3,000 and preparation in plastic vials. This allows for lower activity readings that results in closer precision of the samples' true concentration. Technical Objectives: Create a quench curve and calibrate the LSA for tritium. Verify the calibration of the quench curve prior to cross sample runs. Check calibration against Quality Control (QC) reference value. Conclusion: a tritium quench curve calibration was performed using a scintillation cocktail with ultima gold (AB and AB/F), acetone (only with AB), and water (only with AB/F). By performing the tritium quench curve calibration, the counting efficiency was correlated to various levels of quench. Calibration checks with quality control standards were also performed to verify that the calibration was correct. The observed results provided acceptable values that matched the quality control standard reference values with an acceptable uncertainty. The next step will be fine tuning and cross comparison checks with legacy instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of methods for targeted search of dominant higher modes in subcritical systems

The reactor physics modeling of subcritical systems requires a substantially different approach from that of a critical reactor due to the presence of the so-called higher modes. Earlier investigations showed that the dominant higher modes lie in the inner part of the eigenvalue spectrum, making the conventional eigenvalue searches unfeasible and calling for a targeted search. This paper investigates the possibility of targeted and multitudinous eigenvalue calculation by testing the Krylov-Schur and the Dynamic Modes Decomposition (DMD) method for simple, analytically tractable problems. While the DMD method clearly showed its efficiency in a one-group homogeneous problem, modal analysis of a three-dimensional reflected reactor in two-groups approximation demonstrated that the increasing complexity poses challenges for both methods. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Lost and Found Opportunities Around the Chlorine Worth Study

Los Alamos National Laboratory performed a series of critical experiments in 2021 to examine the worth of chlorine in plutonium-fueled systems. This series of experiments has been dubbed the “Chlorine Worth Study,” and the evaluation of the experiments was presented to the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Technical Review Group in April, 2023. The primary purpose of these experiments was to enable validation of aqueous solutions crediting neutron absorption in 35 Cl. An external, independent view of the events leading up to the design and execution of these experiments indicates a missed opportunity to leverage sensitivity/uncertainty (S/U) analysis to assert validation without the experiments by taking an additional margin for the lack of direct validation of chlorine. On the other hand, the execution of these experiments also presents a rare opportunity to examine the efficacy of the S/U approach and extract useful information about the evaluated chlorine covariance data. TSUNAMI-1D models of representative application solutions were created and used to generate sensitivity data. Varying plutonium and chlorine concentrations were considered to examine the impact of these differences on the chlorine sensitivities and uncertainties. The data-induced uncertainty in k eff resulting from chlorine was calculated directly from uncertainty information calculated in the TSUNAMI-1D sequence. In all cases, this uncertainty was less than 0.1 %Δk. This result could potentially be used to justify a reactivity margin to account for the validation gap related to chlorine in the validation set. On the other hand, given that the experiments were performed, the community should endeavor to extract as much value from them and their results as possible. The results can be used to examine the actual bias associated with chlorine in these systems once the evaluations have been released. These data can be compared with the data-induced uncertainty margin discussed above to test the sufficiency of the validation gap penalty. This result will provide an indication of the performance of the chlorine covariance data specifically and the S/U validation approach generally. More advanced S/U techniques may also be employed to determine reactivity sensitivities associated with the chlorine in the experiments, potentially generating a more robust test of the chlorine covariance data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Case for and Against a Gadolinium Bias in SCALE: Round 2

The “Opening Arguments” for and against a gadolinium bias in SCALE were presented at the American Nuclear Society Annual Meeting in Philadelphia, Pennsylvania, in June, 2018. Some critical experiments included in the Oak Ridge National Laboratory Verified, Archived Library of Inputs and Data (VALID) indicate a significant bias as a function of gadolinium concentration. Other experiments indicate that no significant bias exists. The work presented here develops a larger suite of gadolinium-bearing benchmark models to further examine code, data, and benchmark performance. The new benchmark models have been reviewed for accuracy, but documentation and review for addition to the VALID library have not been completed. The problematic benchmarks included in VALID are HEU-SOL-THERM-014 and -016. These are two evaluations from a series of experiments from the Institute for Physics and Power Engineering (IPPE), Russia, documented in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The entire set of evaluations also includes HEU-SOL-THERM-015, -017, -018, -019, and -025. Each evaluation contains a different uranium concentration, and different configurations within each evaluation include different gadolinium concentrations. These 7 evaluations contain a total of 52 configurations and form the largest subset of experiments considered, and they allow for a more complete assessment of the performance of these benchmarks than has historically been possible using just the HEU-SOL-THERM-014 and -016 results. Additional solution experiments are considered, including MIX-SOL-THERM-006 and -007 and PU-SOL-THERM-034. MIX-SOL-THERM-007 is in the VALID library, whereas MIX-SOL-THERM-006 and PU-SOL-THERM-034 are not. The results for MIX-SOL THERM-007 have not shown a gadolinium trend. These mixed- and plutonium-fueled solutions include 28 configurations. Some experiments including solid fuel and solid gadolinium are also included. These experiments include highly enriched uranium (HEU) foils moderated with polyethylene in HEU-MET-THERM-010, -016, and -034, and low enriched uranium (LEU) pin arrays with gadolinia absorber rods in LEU-COMP THERM-036 and -043. A total 32 cases with solid fuel are included. The IPPE solution benchmarks show a fairly high degree of variability, but no clear trend as a function of gadolinium concentration can be observed. The mixed- and plutonium-fueled solutions show less variability than the HEU solutions and also no trend relative to gadolinium concentration. The solid-fueled experiments also show no trend as a function of gadolinium content. The entire set of benchmarks shows no clear trend on gadolinium content or the energy of the average neutron lethargy causing fission.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analytic Sensitivity Coefficients for General Multigroup Infinite Medium k-Eigenvalue Problems

The general multigroup infinite medium k-eigenvalue neutron transport equation is used to derive analytic expressions for the infinite medium k-eigenvalue, the scalar neutron flux and adjoint, and the sensitivity of $k$ ∞ to perturbations in the multigroup nuclear data of a single species isotropic elastic scattering material. In the appendix, we present the multigroup nuclear data for U-235 and U-238 along with the corresponding k-eigenvalue, flux, adjoint, and sensitivity profiles, which include the sensitivity of $k$ ∞ to the total, fission, capture, and scattering macroscopic cross sections as well as to the group-to-group scattering cross section matrix, group neutron production, and the unconstrained and constrained fission neutron energy distribution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Standardization of chemical analytical techniques for pyrolysis bio-oil: history, challenges, and current status of methods

Here, we discuss the standardization of analytical techniques for pyrolysis bio-oils, including the current status of methods, and our opinions on future directions. First, the history of past standardization efforts is summarized, and both successful and unsuccessful validation of analytical techniques highlighted. The majority of analytical standardization studies to-date has tested only physical characterization techniques. In this paper, we present results from an international round robin on the validation of chemical characterization techniques for bio-oils. Techniques tested included acid number, carbonyl titrations using two different methods (one at room temperature and one at 80 °C), 31 P NMR for determination of hydroxyl groups, and a quantitative gas chromatography–mass spectrometry (GC-MS) method. Both carbonyl titration and acid number methods have yielded acceptable inter-laboratory variabilities. 31 P NMR produced acceptable results for aliphatic and phenolic hydroxyl groups, but not for carboxylic hydroxyl groups. As shown in previous round robins, GC-MS results were more variable. Reliable chemical characterization of bio-oils will enable upgrading research and allow for detailed comparisons of bio-oils produced at different facilities. Reliable analytics are also needed to enable an emerging bioenergy industry, as processing facilities often have different analytical needs and capabilities than research facilities. We feel that correlations in reliable characterizations of bio-oils will help strike a balance between research and industry, and will ultimately help to -determine metrics for bio-oil quality. Lastly, the standardization of additional analytical methods is needed, particularly for upgraded bio-oils.

09 BIOMASS FUELS↗

Bridging Equipment Reliability Data and Robust Decisions in a Plant Operation Context

In order to reduce operation and maintenance (O&M) costs, nuclear power plants (NPPs) are moving from corrective and periodic maintenance to predictive maintenance strategies. Such transition requires changes on the data that needs to be retrieved and on the type of decision processes to be employed. Advanced monitoring and data analysis technologies are essential to support predictive strategies. They can in fact provide precise information about health of a component, track its degradation trends, and provide information of its expected failure time. With such information, maintenance operations for a component can be performed right before its expected failure time. This dynamic context of O&M operations requires new methods to analyze data, propagate component health information from the component to the system level, and optimize plant resources. In this respect, the risk informed asset management (RIAM) project has been tasked to develop and test this new class of methods into a risk analytics toolset. This toolset consists of data analytics tools coupled with reliability methods designed to manage plant assets and performances in a predictive maintenance context. This report shows the latest improvements on such development and the initial testing of our methods on the three main research areas that the RIAM project is focusing on. These areas are the following: equipment reliability data analytics, system reliability modeling, and plant resources optimization methods. We show how the methods developed in these areas can support predictive maintenance strategies by: 1) analyzing equipment reliability data (either in numeric and textual form), 2) assessing component and system health through an innovative margin-based reliability approach, and 3) identifying the most critical components and set optimal maintenance schedule based on plant economic and operational constraints.

97 MATHEMATICS AND COMPUTING↗

HPTLC Plate Blotting for Liquid Microjunction Surface Sampling Probe Mass Spectrometric Analysis of Analytes Separated on a Wettable Phase Plate

A blotting method that transfers analytes separated on wettable HPTLC plates to a hydrophobic reversed-phase C8 HPLTC plate suitable for analysis with a liquid microjunction surface sampling probe electrospray ionization mass spectrometry system was described and demonstrated. The simple blotting procedure transfers the analyte from the wettable plate to the topmost surface of a rigidly backed, easy-to-mount hydrophobic substrate that already has been proven viable for analysis by this sampling probe/mass spectrometry system. The utility of the approach was demonstrated by the analysis of a four-component peptide mixture originally separated on a ProteoChrom HPTLC cellulose sheet and then blotted to the reversed phase HPTLC plate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Dynamics of Ions on Phased Radio-frequency Carpets in High Pressure Gases and Application for Barium Tagging in Xenon Gas Time Projection Chambers

Radio-frequency (RF) carpets with ultra-fine pitches are examined for ion transport in gases at atmospheric pressures and above. We develop new analytic and computational methods for modeling RF ion transport at densities where dynamics are strongly influenced by buffer gas collisions. An analytic description of levitating and sweeping forces from phased arrays is obtained, then thermodynamic and kinetic principles are used to calculate ion loss rates in the presence of collisions. This methodology is validated against detailed microscopic SIMION simulations. We then explore a parameter space of special interest for neutrinoless double beta decay experiments: transport of barium ions in xenon at pressures from 1 to 10 bar. Our computations account for molecular ion formation and pressure dependent mobility as well as finite temperature effects. We discuss the challenges associated with achieving suitable operating conditions, which lie beyond the capabilities of existing devices, using presently available or near-future manufacturing techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method and apparatus for continuous fluid leak monitoring and detection in analytical instruments and instrument systems

A method and device are disclosed that provide for detection of fluid leaks in analytical instruments and instrument systems. The leak detection device includes a collection tube, a fluid absorbing material, and a circuit that electrically couples to an indicator device. When assembled, the leak detection device detects and monitors for fluid leaks, providing a preselected response in conjunction with the indicator device when contacted by a fluid.

47 OTHER INSTRUMENTATION↗

Portable apparatus for separating sample and detecting target analytes

Portable devices and methods for determining the presence of a target analyte using a portable device are provided. The portable device is preferably hand-held. A sample is injected to the portable device. A microfluidic separation is performed within the portable device and at least one separated component detected by a detection module within the portable device, in embodiments of the invention. A target analyte is identified, based on the separated component, and the presence of the target analyte is indicated on an output interface of the portable device, in accordance with embodiments of the invention.

Renzi, Ronald F↗