Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “uncertainty relation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Improved experimental and diagnostic techniques for dynamic tensile stress–strain measurement with a Kolsky tension bar

Kolsky tension bar experiments were improved for dynamic tensile stress–strain measurements with higher fidelity and minimal uncertainties. The difficulties associated with specimen gripping, relatively short gage section, and geometric discontinuity at the bar ends all compromise the accuracy of the traditional strain measurement method in a Kolsky tension bar experiment. Here in this study, an improved three-channel splitting-beam laser extensometer technique was developed to directly and independently track the displacement of the incident and transmission bar interfaces. By adopting a dual-channel configuration on the incident bar side, the resolution and measurement range of this laser extensometer were coordinated between the two channels to provide highly precise measurement at both small and large strains under high strain-rate loading condition. On the transmission bar side an amplified channel, similar to that used on the incident bar side, was adopted to measure the transmission bar displacement with high resolution. With this novel design, a maximum resolution of approximately 500 nm can be obtained for the bar displacement measurement, which corresponds to a strain of 0.0079% for a specimen with 6.35 mm gage length. To further improve the accuracy, a pair of lock nuts were used to tighten the tensile specimen to the bars in an effort not only to prevent the specimen from potential pre-torsional deformation and damage during installation, but also to provide better thread engagement between the specimen and the bar ends. As a demonstration of this technique, dynamic tensile stress–strain response of a 304L stainless steel was characterized with high resolution in both elastic and plastic deformations.

42 ENGINEERING↗

SU-F-T-572: Small Fields Output Factors Measurement and Correction Factor Determination for Several Active and Passive Detectors

Purpose: To measure the output factor (OF) and output correction factors (OCF) of small circular cones using various active and passive detectors. Methods: The OF of BrainLab circular cones of 4, 6, 7.5, 10, 12.5 and 15mm diameter were measured isocentrically at 15mm depth for 6 MV X-rays at 1000 MU/min from Novalis-Tx Linac using high resolution diodes (SFD, Edge, PTW60008), plastic scintillator (ExtradinW1), small ionization chamber (CC01), EBT3 film and Al2O3:C OSLDs (nanoDot). OCF was calculated as a ratio of the OF of each detector relative to EBT3. Long term overall measurement uncertainty were estimated from the 15 repeat measurement performed for each detector over a period of 1year Results: The mean OF measured using various detectors are shown in the figure. In comparison to EDR3 measurement, nanoDot, CC01 and ExtradinW1 showed consistently lower OF upto −25.7% (nanoDot) which gradually improves with cone size (Table). The variation in OF measure with CC01 and ExtradinW1 for cone size >10mm is within −1.4% and −1.9%. Whereas, Edge and PTW60008 measured consistently larger OF except for 4mm cone. All diodes showed better agreement with EDR3 with maximum variation within ±1.7% (SFD), 2.5% (Edge) and 4.4% (PTW60008). The OCF was largest for nanoDot (range 1.04–1.35) and least for the diodes (range 0.97–1.04). The estimated overall long term standard uncertainty (k=2, 95% confidence) were highest for nanoDot at 3% followed by 2.43% for EDR3, 1% for SFD, 0.49% for ExtradinW1, 0.42% for CC01 and PTW60008, 0.16% for edge. Conclusion: Largest OF for the smallest cone was observed from EDR3. Although correction factor needed for all diodes were very similar, Edge showed most consistent result. nanoDot in its present form is not suitable for OF measurement from small fields. ExtradinW1 with its stem oriented perpendicular to beam axis underestimate OF for field size ≤10mm and need further investigation.

60 APPLIED LIFE SCIENCES↗