At least 1,621 records · Page 90

Results of a M = 5.3 heat transfer test of the integrated vehicle using phase-change paint techniques on the 0.0175-scale model 56-OTS in the NASA/Ames Research Center 3.5-foot hypersonic wind tunnel

An experimental investigation was performed in the NASA/Ames Research Center 3.5-foot Hypersonic Wind Tunnel to obtain supersonic heat-distribution data in areas between the orbiter and external tank using phase-change paint techniques. The tests used Novamide SSV Model 56-OTS in the first and second-stage ascent configurations. Data were obtained at a nominal Mach number of 5.3 and a Reynolds number per foot of 5 x 10 to the 6th power with angles of attack of 0 deg, +/- 5 deg, and sideslip angles of 0 deg and +/- 5 deg.

Marroquin, J.↗

Flammability testing conducted in support of Apollo 13

In support of the Apollo 13 investigation of the oxygen tank failure, flame propagation rates were determined for Teflon insulation in cryogenic and ambient temperature oxygen for upward, downward, and zero g burns. The propagation rates depended heavily on configuration and varied from 4.8 to 10.9 cm/sec for upward one g burns to 0.48 cm/sec for zero g burns. In addition to the flame propagation rates, tests were conducted to determine if Teflon burning in cryogenic oxygen could ignite metals (promoted ignition) with which it came in contact. Tests conducted on various metal alloys used in the oxygen tank indicated that most of the alloys could be ignited by burning Teflon in certain configurations. After the propagation rates and promoted metal ignitions had been evaluated, a test was conducted on a quantity gauge and wire harness used in the oxygen tank to determine if flame propagation to the tank wall was possible. Propagation of the wire bundle after ignition resulted in a catastrophic failure of the test vessel in the area of the quantity gauge.

Leger, L. J.↗

Derivation of mass and stiffness matrices from dynamic test data.

A technique is described by which orthonormal modal vectors, computed from dynamic test response data, are used to derive mass, stiffness, and damping matrices for a discrete model of the distributed elastic system. Matrices thus computed from subsystems tests may be readily incorporated into larger system models. The method has been applied to a test of the Saturn V S-II stage LOX tank-engine support system. The dynamic responses of the discrete model are shown to correlate well with test data throughout the frequency range tested.

Thoren, A. R.↗

Cryopumping in Cryogenic Insulations for a Reusable Launch Vehicle

Testing at cryogenic temperatures was performed to verify the material characteristics and manufacturing processes of reusable propellant tank cryogenic insulations for a Reusable Launch Vehicle (RLV). The unique test apparatus and test methods developed for the investigation of cryopumping in cryogenic insulations are described. Panel level test specimens with various types of cryogenic insulations were subjected to a specific thermal profile where the temperature varied from -262 C to 21 C. Cryopumping occurred if the interior temperature of the specimen exhibited abnormal temperature fluctuations, such as a sudden decrease in temperature during the heating phase.

Johnson, Theodore F.↗

Detection and Characterization of Imperfections in Composite Pressure Vessels

The thermographic evaluation of composite structures for delaminations, disbonds, inclusions, porosity and microcracking has proven to be a valuable asset in the field of nondestructive testing. Coupling large area coverage, variable sensitivity and minimal surface contact with a photographic type image representation of structural anomalies; thermography has become a primary inspection method for composite structures. Thermography works well for locating both surface and subsurface defects in most composite systems ranging in thickness of up to 0.25 inch (0.64 cm) or more. The thermographic method for inspection of composite structures typically involves applying an external source of heat to the structure and then recording the changes in the surface heat profile manifested by embedded defects or by material property variations. If these temperature variations are large enough and an infrared camera with sufficient sensitivity is used, then the material or structural abnormality can be detected and referred back to its source. Interpreting the information given in a thermogram, can be a difficult task under ideal circumstances and extremely challenging in a real world setting. Variables including depth, thermal conductivity, orientation and size of the abnormality can all have a great influence on how its heat pattern will be seen by the imager. The work discussed in this paper illustrates how the microstructure of several commonly found defects in composite structures relate to their thermographic image counterpart. Two test cases are studied herein, including a large graphite/epoxy RP-1 fuel tank and a graphite composite cryogenic fuel feedline. The structures used in this study were designed to serve as manufacturing proof of concept specimens and to undergo hydroburst testing to verify manufacturing practices and structural design. Prior to hydrostatic testing the structures underwent 100% thermographic evaluation to ensure that no manufacturing or handling damage was present. Due to a large inclusion found in the feedline, it was pulled from service and dissected without performing the hydroproof The thermographic indications found in the RP-1 tank were below critical limits so it underwent a complete hydroproof loading series and finally a hydroburst. Following the hydroburst samples were cut from the tank in regions where thermography had located damage before the test. These regions were thermographically and then were cross-sectioned and photomicrographed.

Walker, James L.↗

Performance of cross-flow turbines with varying blade materials and unsupported blade span

Cross-flow turbines could play a larger role in the diversification of the global energy supply if the impact of more cost-competitive design choices on performance and rotor dynamics was better understood. This study focuses on rotor performance and blade strain measurements while varying the following parameters: blade materials and blade free end length by changing strut support position. Towing tank experiments were performed with a modular 1-meter diameter cross-flow turbine consisting of three NACA 0018 blades with two support struts. One strut was fixed at the lower end of the turbine, while the second strut was adjustable, thereby changing the length of the free end. The blade materials tested were carbon, E-glass, and hollow E-glass fiber composites, in decreasing order of stiffness and cost. High-resolution distributed fiber optic sensors were embedded in two of the three rotor blades for each material and provided hundreds of strain measurements per blade. Turbine performance and blade strain were measured while varying tow speed and tip speed ratio. Performance tests were conducted at towing speeds sufficiently high for the performance to be independent of Reynolds number. E-glass blades and carbon blades performed similarly for the most rigid strut configurations. Higher strain was measured on the E-glass blades, and their performance was reduced for less rigid configurations compared to the carbon fiber blades. The performance of the highly deflective hollow E-glass blades was lower overall and became even more degraded for longer unsupported blade span. Furthermore, the results provide insight into the use of various blade materials in cross-flow turbines and guidance on allowable free end length for each material type.

16 TIDAL AND WAVE POWER↗

Runtime and Pressurization Analyses of Propellant Tanks

Multi-element unstructured CFD has been utilized at NASA SSC to carry out analyses of propellant tank systems in different modes of operation. The three regimes of interest at SSC include (a) tank chill down (b) tank pressurization and (c) runtime propellant draw-down and purge. While tank chill down is an important event that is best addressed with long time-scale heat transfer calculations, CFD can play a critical role in the tank pressurization and runtime modes of operation. In these situations, problems with contamination of the propellant by inclusion of the pressurant gas from the ullage causes a deterioration of the quality of the propellant delivered to the test article. CFD can be used to help quantify the mixing and propellant degradation. During tank pressurization under some circumstances, rapid mixing of relatively warm pressurant gas with cryogenic propellant can lead to rapid densification of the gas and loss of pressure in the tank. This phenomenon can cause serious problems during testing because of the resulting decrease in propellant flow rate. With proper physical models implemented, CFD can model the coupling between the propellant and pressurant including heat transfer and phase change effects and accurately capture the complex physics in the evolving flowfields. This holds the promise of allowing the specification of operational conditions and procedures that could minimize the undesirable mixing and heat transfer inherent in propellant tank operation. It should be noted that traditional CFD modeling is inadequate for such simulations because the fluids in the tank are in a range of different sub-critical and supercritical states and elaborate phase change and mixing rules have to be developed to accurately model the interaction between the ullage gas and the propellant. We show a typical run-time simulation of a spherical propellant tank, containing RP-1 in this case, being pressurized with room-temperature nitrogen at 540 R. Nitrogen, shown in blue on the right-hand side of the figures, enters the tank from the diffuser at the top of the figures and impinges on the RP-1, shown in red, while the propellant is being continuously drained at the rate of 1050 lbs/sec through a pipe at the bottom of the tank. The sequence of frames in Figure 1 shows the resultant velocity fields and mixing between nitrogen and RP-1 in a cross-section of the tank at different times. A vortex is seen to form in the incoming nitrogen stream that tends to entrain propellant, mixing it with the pressurant gas. The RP-1 mass fraction contours in Figure 1 are also indicative of the level of mixing and contamination of the propellant. The simulation is used to track the propagation of the pure propellant front as it is drawn toward the exit with the evolution of the mixing processes in the tank. The CFD simulation modeled a total of 10 seconds of run time. As is seen from Figure 1d, after 5.65 seconds the propellant front is nearing the drain pipe, especially near the center of the tank. Behind this pure propellant front is a mixed fluid of compromised quality that would require the test to end when it reaches the exit pipe. Such unsteady simulations provide an estimate of the time that a high-quality propellant supply to the test article can be guaranteed at the modeled mass flow rate. In the final paper, we will discuss simulations of the LOX and propellant tanks at NASA SSC being pressurized by an inert ullage. Detailed comparisons will be made between the CFD simulations and lower order models as well as with test data. Conditions leading to cryo collapse in the tank will also be identified.

Field, Robert E.↗

Fischer-Tropsch Synthesis: Cd, In and Sn Effects on a 15%Co/Al 2 O 3 Catalyst

The effects of 1% of Cd, In and Sn additives on the physicochemical properties and Fischer-Tropsch synthesis (FTS) performance of a 15% Co/Al 2 O 3 catalyst were investigated. The fresh and spent catalysts were characterized by BET, temperature programmed reduction (TPR), H 2 -chemisorption, NH 3 temperature programmed desorption (TPD), X-ray absorption near edge spectroscopy (XANES), and X ray diffraction (XRD). The catalysts were tested in a 1 L continuously stirred tank reactor (CSTR) at 220 °C, 2.2 MPa, H 2 /CO = 2.1 and 20–55% CO conversion. Addition of 1% of Cd or In enhanced the reduction degree of 15%Co/Al 2 O 3 by ~20%, while addition of 1% Sn slightly hindered it. All three additives adversely impacted Co dispersion by 22–32% by increasing apparent Co cluster size based on the H 2 -chemisorption measurements. However, the decreased Co active site density resulting from the additives did not result in a corresponding activity loss; instead, the additives decreased the activity of the Co catalysts to a much greater extent than expected, i.e., 82–93%. The additional detrimental effect on catalyst activity likely indicates that the Cd, In and Sn additives migrated to and covered active sites during reaction and/or provided an electronic effect. XANES results showed that oxides of the additives were present during the reaction, but that a fraction of metal was also likely present based on the TPR and reaction testing results. This is in contrast to typical promoters that become metallic at or below ~350 °C, such as noble metal promoters (e.g., Pt, Ru) and Group 11 promoters (e.g., Ag, Au) on Co catalysts in earlier studies. In the current work, all three additives remarkably increased CH 4 and CO 2 selectivities and decreased C 5+ selectivity, with the Sn and In additives having a greater effect. Interestingly, the Cd, In, or Sn additives were found to influence hydrogenation and isomerization activities. At a similar conversion level (i.e., in the range of 40–50%), the additives significantly increased 2-C 4 olefin content from 3.8 to 10.6% and n-C 4 paraffin from 50 to 61% accompanied by decreases in 1-C 4 olefin content from 48 to 30%. The Sn contributed the greatest impact on the secondary reactions of 1-olefins, followed by the In and Cd. NH 3 -TPD results suggest enhanced acid sites on cobalt catalysts resulting from the additives, which likely explains the change in selectivities for the different catalysts.

36 MATERIALS SCIENCE↗

ALTERNATIVE AND ENHANCED CHEMICAL CLEANING: CORROSION STUDIES RESULTS: FY2010

Due to the need to close High Level Waste storage tanks, chemical cleaning methods are needed for the removal of sludge heel materials remaining at the completion of mechanical tank cleaning efforts. Oxalic acid is considered the preferred cleaning reagent for heel dissolution of iron-based sludge. However, the large quantity of chemical reagents added to the tank farm from oxalic acid based cleaning has significant downstream impacts. Optimization of the oxalic acid cleaning process can potentially reduce the downstream impacts from chemical cleaning. To optimize oxalic acid usage, a detailed understanding of the chemistry of oxalic acid based sludge dissolution is required. Additionally, other acidic systems may be required for specific waste components that have low solubility in oxalic acid, and as a means to reduce oxalic acid usage in general. Electrochemical corrosion studies were conducted with 1 wt. % oxalic acid at mineral acid concentrations above and below the optimal conditions for this oxalic acid concentration. Testing environments included pure reagents, pure iron and aluminum phases, and sludge simulants. Mineral acid concentrations greater than 0.2 M and temperatures greater than 50 C result in unacceptably high corrosion rates. Results showed that manageable corrosion rates of carbon steel can be achieved at dilute mineral acid concentrations (i.e. less than 0.2 M) and low temperatures based on the contact times involved. Therefore, it is recommended that future dissolution and corrosion testing be performed with a dilute mineral acid and a less concentrated oxalic acid (e.g., 0.5 wt.%) that still promotes optimal dissolution. This recommendation requires the processing of greater water volumes than those for the baseline process during heel dissolution, but allows for minimization of oxalic acid additions. The following conclusions can be drawn from the test results: (1) In both nitric and sulfuric acid based reagents, the low temperature and dilute concentration environment resulted in carbon steel corrosion rates that were less than 150 mpy. These rates are manageable in that chemical cleaning processes could proceed for limited time without significant wall loss. Further optimization of the Alternative Enhance Chemical Cleaning (AECC) process should focus on testing in solutions of this dilute concentration and low temperature regime. (2) In general, for the nitric acid based reagent, the aluminum oxide phase environments resulted in higher corrosion rates than the iron oxide phase environments. (3) In general, for the sulfuric acid based reagent, the iron oxide phase environments resulted in higher corrosion rates than the aluminum oxide phase environments. (4) In general, for the nitric acid based reagent, the HM sludge simulant environments resulted in higher corrosion rates than the PUREX sludge simulant environments. This result agrees with the previous observation that the aluminum oxide phases are more aggressive than the iron oxide phase environments in the nitric acid reagent. (5) Pitting was more likely to occur in the sulfuric acid based reagents than in the nitric acid based reagents. (6) Pitting occurred only in the iron based pure oxide phases and the sludge simulants. No pitting was observed in the aluminum based pure oxide phases. (7) Pitting tended to occur more frequently in tests that involved the dilute mineral acid reagent. (8) Pitting was more severe at the higher temperature for a given mineral acid concentration. (9) Pitting was more severe at a higher mineral acid concentration for a given temperature. (10) Based on the combined results of the open circuit potential and cathodic polarization testing, there was a low propensity for hydrogen evolution in solutions where sludge has been dissolved.

08 HYDROGEN↗

La Hague STE2 Sludge Retrieval and Conditioning Strategy - 19229

About 9000 m{sup 2} of Long-Lived Intermediate Level Waste LL-ILW STE2 sludges have been generated by the reprocessing operations of UNGG and later UOx fuel in La Hague (UP2-400) and subsequent liquid effluent treatment. They were placed into a set of adjoining tanks, called the STE2 silos. Today, the STE2 Sludges have to be retrieved and conditioned for final disposal in the deep geological repository under development in France (Cigeo). To this end, since the early 2000's, different retrieval and conditioning scenarios have been evaluated. This paper tracks the history of the technical and non-technical key factors having led to the choice of the baseline scenario developed until the end of 2016, describes the technical achievements and makes a state-of the art of the current scenario consisting in retrieving and temporarily storing STE2 sludges and, meanwhile, studying, researching and testing final conditioning processes and technologies in the aim of achieving a technical and economic optimum. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cryogenic Boil-Off Reduction System Testing

Cryogenic propellants such as liquid hydrogen (LH2) and liquid oxygen (LO2) are a part of NASA's future space exploration due to the high specific impulse that can be achieved using engines suitable for moving 10's to 100's of metric tons of payload mass to destinations outside of low earth orbit. However, the low storage temperatures of LH2 and LO2 cause substantial boil-off losses for missions with durations greater than several days. The losses can be greatly reduced by incorporating high performance cryocooler technology to intercept heat load to the propellant tanks and by the integration of self-supporting multi-layer insulation. The active thermal control technology under development is the integration of the reverse turbo- Brayton cycle cryocooler to the propellant tank through a distributed cooling network of tubes coupled to a shield in the tank insulation and to the tank wall itself. Also, the self-supporting insulation technology was utilized under the shield to obtain needed tank applied LH2 performance. These elements were recently tested at NASA Glenn Research Center in a series of three tests, two that reduced LH2 boil-off and one to eliminate LO2 boil-off. This test series was conducted in a vacuum chamber that replicated the vacuum of space and the temperatures of low Earth orbit. The test results show that LH2 boil-off was reduced 60% by the cryocooler system operating at 90K and that robust LO2 zero boil-off storage, including full tank pressure control was achieved.

Propellant Storage↗

Cone Penetrometer Load Cell Temperature and Radiation Testing Results

This report summarizes testing activities performed at the Pacific Northwest National Laboratory to verify the cone penetrometer load cell can withstand the tank conditions present in 241-AN-101 and 241-AN-106. The tests demonstrated the load cell device will operate under the elevated temperature and radiation levels expected to be encountered during tank farm deployment of the device.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of the Impact of Glycolate on ARP and MCU Operations

Savannah River Remediation (SRR) is evaluating an alternate flowsheet for the Defense Waste Processing Facility (DWPF) using glycolic acid as a reductant. An important aspect of the development of the glycolic acid flowsheet is determining if glycolate has any detrimental downstream impacts. Testing was performed to determine if there is any impact to the strontium and actinide sorption by monosodium titanate (MST) and modified monosodium titanate (mMST) or if there is an impact to the cesium removal, phase separation, or coalescer performance at the Modular Caustic-Side Solvent Extraction Processing Unit (MCU). Sorption testing was performed using both MST and modified MST (mMST) in the presence of 5000 and 10,000 ppm (mass basis) glycolate. 10,000 ppm is the estimated bounding concentration expected in the DWPF recycle stream based on DWPF melter flammable gas model results. The presence of glycolate was found to slow the removal of Sr and Pu by MST, while increasing the removal rate of Np. Results indicate that the impact is a kinetic effect, and the overall capacity of the material is not affected. There was no measurable effect on U removal at either glycolate concentration. The slower removal rates for Sr and Pu at 5000 and 10,000 ppm glycolate could result in lower DF values for these sorbates in ARP based on the current (12 hours) and proposed (8 hours) contact times. For the highest glycolate concentration used in this study, the percentage of Sr removed at 6 hours of contact decreased by 1% and the percentage of Pu removed decreased by nearly 7%. The impact may prove insignificant if the concentration of glycolate that is returned to the tank farm is well below the concentrations tested in this study. The presence of glycolate also decreased the removal rates for all three sorbates (Sr, Pu, and Np) by mMST. Similar to MST, the results for mMST indicate that the impact is a kinetic effect, and the overall capacity of the material is not affected. The presence of glycolate did not change the lack of affinity of mMST for U. Pre-contacting the MST or mMST with glycolate did not have a significant effect on the performance of the materials when compared to tests having the same concentration of glycolate present in the simulant. These findings suggest that the glycolate is likely influencing removal by sorbate complexation and not by depositing onto or forming a film on the surface of the MST solids. Since the DF values are salt batch dependent, it is not possible to a priori quantify the impacts of glycolate on future processing campaigns. However, we recommend that the impacts of glycolate be evaluated during each salt batch qualification when a final processing concentration is defined, and recommendations can then be made on how to mitigate negative impacts, if needed. Impacts to the performance of the MST or mMST could be mitigated by increasing contact time or increasing sorbent concentrations. Testing was performed to determine if there is an impact to the cesium removal at Modular Caustic-Side Solvent Extraction Processing Unit (MCU). An Extraction-Scrub-Strip (ESS) test routine was used to simulate cesium removal at the MCU. For this, SRNL performed three ESS tests, using the same basic aqueous waste simulant and solvent. For one test, SRNL added 5000 ppm (mass basis) of glycolate and added 10,000 ppm of glycolate to a second test. A control test contained no glycolate. The results of all three tests were virtually identical for all the extraction, scrub and strip tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of the impact of glycolate on arp and mcu operations

Savannah River Remediation (SRR) is evaluating an alternate flowsheet for the Defense Waste Processing Facility (DWPF) using glycolic acid as a reductant. An important aspect of the development of the glycolic acid flowsheet is determining if glycolate has any detrimental downstream impacts. Testing was performed to determine if there is any impact to the strontium and actinide sorption by monosodium titanate (MST) and modified monosodium titanate (mMST) or if there is an impact to the cesium removal at the Modular Caustic-Side Solvent Extraction Processing Unit (MCU). Sorption testing was performed using both MST and modified MST (mMST) in the presence of 5,000 and 10,000 ppm (mass basis) glycolate. 10,000 ppm is the estimated bounding concentration expected in the DWPF recycle stream based on DWPF melter flammable gas model results. The presence of glycolate was found to slow the removal of Sr and Pu by MST, while increasing the removal rate of Np. Results indicate that the impact is a kinetic effect, and the overall capacity of the material is not affected. There was no measurable effect on U removal at either glycolate concentration. The slower removal rates for Sr and Pu at 5,000 and 10,000 ppm glycolate could result in lower DF values for these sorbates in ARP based on the current (12 hours) and proposed (8 hours) contact times. For the highest glycolate concentration used in this study, the percentage of Sr removed at 6 hours of contact decreased by 1% and the percentage of Pu removed decreased by nearly 7%. The impact may prove insignificant if the concentration of glycolate that is returned to the tank farm is well below the concentrations tested in this study. The presence of glycolate also decreased the removal rates for all three sorbates (Sr, Pu, and Np) by mMST. Similarly to MST, the results for mMST indicate that the impact is a kinetic effect, and the overall capacity of the material is not affected. The presence of glycolate did not change the lack of affinity of mMST for U. Pre-contacting the MST or mMST with glycolate did not have a significant effect on the performance of the materials when compared to tests having the same concentration of glycolate present in the simulant. These findings suggest that the glycolate is likely influencing removal by sorbate complexation and not by depositing onto or forming a film on the surface of the MST solids. Since the DF values are salt batch dependent, it is not possible to a priori quantify the impacts of glycolate on future processing campaigns. However, we recommend that the impacts of glycolate be evaluated during each salt batch qualification when a final processing concentration is defined, and recommendations can then be made on how to mitigate negative impacts, if needed. Impacts to the performance of the MST or mMST could be mitigated by increasing contact time or increasing sorbent concentrations. In addition to the MST and mMST testing, testing was performed to determine if there is an impact to the cesium removal at Modular Caustic-Side Solvent Extraction Processing Unit (MCU). An Extraction-Scrub-Strip (ESS) test routine was used to simulate cesium removal at the MCU. For this, SRNL performed three ESS tests, using the same basic aqueous waste simulant and solvent. For one test, SRNL added 5,000 ppm (mass basis) of glycolate and added 10,000 ppm of glycolate to a second test. A control test contained no glycolate. The results of all three tests were virtually identical for all the extraction, scrub and strip tests. (A single data point in the 5,000 ppm test is physically impossible and SRNL is currently resolving this obvious error.) At this time, SRNL concludes that the presence of up to 10,000 ppm of glycolate does not affect cesium removal by the current solvent system used in the MCU. Although not tested, the impact of glycolate for the Next Generation Solvent - that replaces BOBCalixC6 with MaxCalix - is expected to be very similar to that for the baseline solvent. Testing is needed to confirm. Additional testing is recommended to both further examine the nature of the interaction of glycolate with MST and mMST and also to help address some postulated risks on ARP/MCU operations with implementation of the glycolate flowsheet. The additional testing includes FTIR and Raman spectroscopy to examine the surface of the MST and mMST particles, iodometric titrations to determine the peroxide content in the mMST before and after exposure to glycolate, particle size measurements of the MST and mMST from the experiments performed with glycolate, and measurements of soluble Ti in the supernate from these glycolate experiments. With regards to MCU impacts, the following tests are also recommended based on the premortem risk assessment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cryogenic Fluid In-Situ Liquefaction for Landers: Prototype Demonstration

As the advancement of In-Situ Resource Utilization concepts and systems continue to develop, applicable technology development and maturation continues in parallel. While there are many different ways to use the resources found on other bodies, one of the most prevalent suggested applications is the manufacturing of propellants. One of the key technologies for the eventual use of these propellant production based ISRU systems is the liquefaction and storage of the produced propellants. The most mentioned propellant combinations include oxygen-hydrogen and oxygen-methane. The liquefaction of oxygen in these systems will be different than oxygen liquefaction systems on Earth, which mainly revolves around the distillation of air. These systems have been developed conceptually and many of the components have been previously tested or are in development. However, the need to demonstrate the system level operations still exists. The demonstration of a prototypical oxygen liquefaction system using tube-on-tank broad area cooling was completed to better understanding system level operations during liquefaction activities. Demonstration testing included system performance determination, constant liquefaction demonstrations, and transient liquefaction demonstrations. The demonstrations showed the operational capabilities of the tube-on-tank system with an integrated cryocooler. Additional testing explored subsurface vs ullage introduction of the gaseous oxygen flow stream as well as demonstrating a novel fiber optic sensor that measured the temperature gradients along the fluid center line within the tank.

ISRU↗

Cryogenic Fluid In-Situ Liquefaction for Landers: Prototype Demonstration

As the advancement of In-Situ Resource Utilization concepts and systems continue to develop, applicable technology development and maturation continues in parallel. While there are many different ways to use the resources found on other bodies, one of the most prevalent suggested applications is the manufacturing of propellants. One of the key technologies for the eventual use of these propellant production based ISRU systems is the liquefaction and storage of the produced propellants. The most mentioned propellant combinations include oxygen-hydrogen and oxygen-methane. The liquefaction of oxygen in these systems will be different than that on Earth, which mainly revolves around the distillation of air. These systems have been developed conceptually and many of the components have been previously tested or are in development. However, the need to demonstrate the system level operations still exists. The demonstration of a prototypical oxygen liquefaction system using tube-on-tank broad area cooling was completed to better understanding system level operations during liquefaction activities. Demonstration testing included system performance determination, constant liquefaction demonstrations, and transient liquefaction demonstrations. The demonstrations showed the operational capabilities of the tube-on-tank system with an integrated cryocooler. Additional testing explored subsurface vs ullage introduction of the gaseous oxygen flow stream as well as demonstrating a novel fiber optic sensor that measured the temperature gradients along the fluid center line within the tank.

ISRU↗

Cryogenic Fluid In-Situ Liquefaction for Landers: Prototype Demonstration

As the advancement of In-Situ Resource Utilization concepts and systems continue to develop, applicable technology development and maturation continues in parallel. While there are many different ways to use the resources found on other bodies, one of the most prevalent suggested applications is the manufacturing of propellants. One of the key technologies for the eventual use of these propellant production based ISRU systems is the liquefaction and storage of the produced propellants. The most mentioned propellant combinations include oxygen-hydrogen and oxygen-methane. The liquefaction of oxygen in these systems will be different than oxygen liquefaction systems on Earth, which mainly revolves around the distillation of air. These systems have been developed conceptually and many of the components have been previously tested or are in development. However, the need to demonstrate the system level operations still exists. The demonstration of a prototypical oxygen liquefaction system using tube-on-tank broad area cooling was completed to better understanding system level operations during liquefaction activities. Demonstration testing included system performance determination, constant liquefaction demonstrations, and transient liquefaction demonstrations. The demonstrations showed the operational capabilities of the tube-on-tank system with an integrated cryocooler. Additional testing explored subsurface vs ullage introduction of the gaseous oxygen flow stream as well as demonstrating a novel fiber optic sensor that measured the temperature gradients along the fluid center line within the tank.

ISRU↗

Hydrophobicity of Cryogenic Fluids for Fuel Transfer in Space Applicaitons

Introduction Hydrophobicity is the tendency of a fluid to repel another material or fluid. Hydrophobiciy can be measured through the wetting angle of the fluid on the surface of the other material. The greater the wetting angle, the more hydrophobic the surface is against the fluid. Hydrophobicity properties can be caused by one of two means, either through physical properties or chemical properties [\citenum{NARBUTT2020121}]. Physical hydrophobicity due to the surface of a solid creating surface roughness/patterning, minimizing the contact area between the fluid and the surface. This can be observed throughout nature, such as the surface of lotus leaves or butterfly wings. This physical property can be induced on a variety of surfaces, namely through laser etching, allowing a surface to be finely lineated to imitate these natural surfaces while controlling quantity, depth, and patterns of the etching on the surface [\citenum{10.1063/1.4905616}]. Physical hydrophobicity is therefore dependent on several variables, including the surface that the fluid is on and properties of the fluid itself, such as density and surface tension, both of which are dependent on temperature and/or pressure. Chemical hydrophobicity [\citenum{MadeiraHydrophobocicicici}] is due to the inherent chemical properties of the materials being used. This is most commonly due to the molecular structures changing the polarity of the materials. Depending on a nonpolar material will repel a polar material, proving to be hydrophobic, conversely if the polarity of the materials is the same (polar – polar, nonpolar – nonpolar), they will attract each other. Cryogenics refers to the behavior of materials at very low temperatures (<\ang{-100} C) [\citenum{ZOHURI20181}]. In space applications many things are inherently cryogenic, therefore this is an important field. There has been little research in how hydrophobicity changes at cryogenic temperatures. Cryogenic fluids are commonly used as fuels for spacecraft, therefore, integrating a hydrophobic surface can increase the transfer rate of the fuel. To test this, several experiments were set up to determine the hydrophobic properties of cryogenic fluids, including nitrogen (LN2), argon (LAr), oxygen (LOx), hydrogen (LH2), and methane (CH4), at cryogenic temperatures. Etched Wafer Testing A silicon wafer cut from a crystal of silicon [100] was used to model the potential hydrophobicity of various cryogenic fluids. Silicon [100] references to the crystallographic orientation of the silicon crystals in the wafer. These wafers were then laser etched to create a surface that is more likely to be hydrophobic. To test the hydrophobicity of the wafers at cryogenic temperatures, the temperatures of the wafers must be reduced to the same temperature as the cryogenic fluid being used to prevent rapid boil-off. To achieve this a double-walled vacuum insulated glass chamber was utilized. The chamber is open, with a double-walled glass that can be placed in a vacuum to remove condensation from the outside to allow easier viewing of the experiment. Furthermore, the silicon wafer's temperature must be lowered to the temperature of LN2, as well as maintain the temperature throughout the experiment. To achieve this a piece of 6061 aluminum was used, creating a stand-off for the wafer and it would allow for the insulation of the temperature of the wafers. The container was then filled with LN2 and once the LN2 stabilized the vaporization and the levels of LN2 dropped under the height of the wafer, the wafer was then allowed to air dry. Once the wafer was dry from the LN2, drops of LN2 were placed on the surface of the wafer for observation. During the first trial, the LN2 that was dropped on the surface displayed nonhydrophobic behaviors, spreading out along the surface, with a minimal wetting angle (too small to be measured). This process was repeated for liquid argon. Further testing with other cryogenic liquids will require different testing apparatuses due to being more volatile. Furthermore, several papers [\citenum{voltvolt7}] have suggested that running a voltage can induce a hydrophobic effect throughout a surface, further testing will include a voltage (constant and oscillating) to determine if voltage influences inducing hydrophobicity at cryogenic temperatures. Chemical Testing Coating the interior walls of the fuel tanks and fuel lines can successfully create a hydrophobic surface. The inherent problem is finding a material that can be used to coat the surface, furthermore, at these temperatures, the coating will remain solid, which could pose issues in maintaining the hydrophobic properties. To test this water (polar) is hydrophobic against oils and fats (nonpolar), therefore the same experiment as the etched wafer testing was conducted to determine if the hydrophobic properties will persist as the nonpolar material remains solid and the polar material remains a fluid. The water remained hydrophobic, allowing testing can expand to the cryogenic fluids. However, another hurdle is faced in finding a chemically opposite material to the cryogenic fluids being tested. As many of the cryogenic fluids being tested are diatomic, they are inherently nonpolar, therefore, the material used for the hydrophobic coating must be polar. Polar greases and lubricants are difficult to come by, however, lithium stearate, appears to be a potential candidate for creating a coated hydrophobic surface for cryogenic fluids at cryogenic temperatures.

Cryogenics↗