Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “target setting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Fragment-based determination of a proteinase K structure from MicroED data using ARCIMBOLDO_SHREDDER

Structure determination of novel biological macromolecules by X-ray crystallography can be facilitated by the use of small structural fragments, some of only a few residues in length, as effective search models for molecular replacement to overcome the phase problem. Independence from the need for a complete pre-existing model with sequence similarity to the crystallized molecule is the primary appeal of ARCIMBOLDO , a suite of programs which employs this ab initio algorithm for phase determination. Here, the use of ARCIMBOLDO is investigated to overcome the phase problem with the electron cryomicroscopy (cryoEM) method known as microcrystal electron diffraction (MicroED). The results support the use of the ARCIMBOLDO_SHREDDER pipeline to provide phasing solutions for a structure of proteinase K from 1.6 Å resolution data using model fragments derived from the structures of proteins sharing a sequence identity of as low as 20%. ARCIMBOLDO_SHREDDER identified the most accurate polyalanine fragments from a set of distantly related sequence homologues. Alternatively, such templates were extracted in spherical volumes and given internal degrees of freedom to refine towards the target structure. Both modes relied on the rotation function in Phaser to identify or refine fragment models and its translation function to place them. Model completion from the placed fragments proceeded through phase combination of partial solutions and/or density modification and main-chain autotracing using SHELXE . The combined set of fragments was sufficient to arrive at a solution that resembled that determined by conventional molecular replacement using the known target structure as a search model. This approach obviates the need for a single, complete and highly accurate search model when phasing MicroED data, and permits the evaluation of large fragment libraries for this purpose.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of the fast electrons distribution produced in a high intensity laser target interaction

Experiments on the Titan laser (∼150 J, 0.7 ps, 2 × 10{sup 20} W cm{sup −2}) at the Lawrence Livermore National Laboratory were carried out in order to study the properties of fast electrons produced by high-intensity, short pulse laser interacting with matter under conditions relevant to Fast Ignition. Bremsstrahlung x-rays produced by these fast electrons were measured by a set of compact filter-stack based x-ray detectors placed at three angles with respect to the target. The measured bremsstrahlung signal allows a characterization of the fast electron beam spectrum, conversion efficiency of laser energy into fast electron kinetic energy and angular distribution. A Monte Carlo code Integrated Tiger Series was used to model the bremsstrahlung signal and infer a laser to fast electron conversion efficiency of 30%, an electron slope temperature of about 2.2 MeV, and a mean divergence angle of 39°. Simulations were also performed with the hybrid transport code ZUMA which includes fields in the target. In this case, a conversion efficiency of laser energy to fast electron energy of 34% and a slope temperature between 1.5 MeV and 4 MeV depending on the angle between the target normal direction and the measuring spectrometer are found. The observed temperature of the bremsstrahlung spectrum, and therefore the inferred electron spectrum are found to be angle dependent.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Background analysis and status of the ANAIS dark matter project

ANAIS (Annual modulation with NaI Scintillators) is a project aiming to set up at the new facilities of the Canfranc Underground Laboratory (LSC), a large scale NaI(Tl) experiment in order to explore the DAMA/LIBRA annual modulation positive result using the same target and technique. Two 12.5 kg each NaI(Tl) crystals provided by Alpha Spectra took data at the LSC in the ANAIS-25 set-up. The comparison of the background model for the ANAIS-25 prototypes with the experimental results is presented. ANAIS crystal radiopurity goals have been achieved for {sup 232}Th and {sup 238}U chains, but a {sup 210}Pb contamination out-of-equilibrium was identified, whose origin has been studied. The high light collection efficiency obtained with these prototypes allows to anticipate an energy threshold of the order of 1 keVee. A new detector, with improved performances, was received in March 2015 and very preliminary results are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

One-shot gas detection with transformer paired neural networks in Mako collected longwave infrared hyperspectral imagery

To date, careful data treatment workflows and statistical detectors are used to perform hyperspectral image (HSI) detection of any gas contained in a spectral library, which is often expanded with physics models to incorporate different spectral characteristics. In general, surrounding evidence or known gas-release parameters are used to provide confidence in or confirm detection capability, respectively. This makes quantifying detection performance difficult as it is nearly impossible to develop an absolute ground truth for gas target pixel presence in collected HSI. Consequently, developing and comparing new detection methods, especially machine learning (ML)-based methods, is susceptible to subjectivity in derived detection map quality. Here, in this work, we demonstrate the first use of transformer-based paired neural networks (PNNs) for one-shot gas target detection for multiple gases while providing quantitative classification and detection metrics for their use on labeled data. Terabytes of training data are generated from a database of long-wave infrared HSI obtained from historical Mako sensor campaigns over Los Angeles. By incorporating labels, singular signature representations, and a model development pipeline, we can tune and select PNNs to detect multiple gas targets that are not seen in training on a quantitative basis. We additionally assess our test set detections using interpretability techniques widely employed with ML-based predictors, but less common with detection methods relying on learned latent spaces.

Hyperspectral imaging↗

Comparative efficacy of 177 Lu and 90 Y for Anti-CD20 Pretargeted Radioimmunotherapy in Murine Lymphoma Xenograft Models

Purpose Pretargeted radioimmunotherapy (PRIT) is a multi-step method of selectively delivering high doses of radiotherapy to tumor cells while minimizing exposure to surrounding tissues. Yttrium-90 ( 90 Y) and lutetium-177 ( 177 Lu) are two of the most promising beta-particle emitting radionuclides used for radioimmunotherapy, which despite having similar chemistries differ distinctly in terms of radiophysical features. These differences may have important consequences for the absorbed dose to tumors and normal organs. Whereas 90 Y has been successfully applied in a number of preclinical and clinical radioimmunotherapy settings, there have been few published pretargeting studies with 177 Lu. We therefore compared the therapeutic potential of targeting either 90 Y or 177 Lu to human B-cell lymphoma xenografts in mice. Methods Parallel experiments evaluating the biodistribution, imaging, dosimetry, therapeutic efficacy, and toxicity were performed in female athymic nude mice bearing either Ramos (Burkitt lymphoma) or Granta (mantle cell lymphoma) xenografts, utilizing an anti-CD20 antibodystreptavidin conjugate (1F5-SA) and an 90 Y- or 177 Lu-labeled 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA)-biotin second step reagent. Results The two radionuclides displayed comparable biodistributions in tumors and normal organs; however, the absorbed radiation dose delivered to tumor was more than twice as high for 90 Y (1.3 Gy/MBq) as for 177 Lu (0.6 Gy/MBq). More importantly, therapy with 90 Y-DOTAbiotin was dramatically more effective than with 177 Lu-DOTA-biotin, with 100% of Ramos xenograft-bearing mice cured with 37 MBq 90 Y, whereas 0% were cured using identical amounts of 177 Lu-DOTA-biotin. Similar results were observed in mice bearing Granta xenografts, with 80% of the mice cured with 90 Y-PRIT and 0% cured with 177 Lu-PRIT. Toxicities were comparable with both isotopes. Conclusion 90 Y was therapeutically superior to 177 Lu for streptavidin-biotin PRIT approaches in these human lymphoma xenograft models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Machining Elimination through Application of Thread Forming Fasteners in Net-Shaped Cast Holes

The ultimate objective of this work was to eliminate approximately 30% of the machining performed in typical automotive engine and transmission plants by using thread forming fasteners in as-cast holes of aluminum and magnesium cast components. The primary issues at the source of engineers reluctance to implementing thread forming fasteners in lightweight castings are: • Little proof of consistency of clamp load vs. input torque in either aluminum or magnesium castings. • No known data to understand the effect on consistency of clamp load as casting dies wear. The clamp load consistency concern is founded in the fact that a portion of the input torque used to create clamp load is also used to create threads. The torque used for thread forming may not be consistent due to variations in casting material, hole size and shape due to tooling wear and process variation (thermal and mechanical). There is little data available to understand the magnitude of this concern or to form the basis of potential solutions if the range of clamp load variation is very high (> +/- 30%). The range of variation that can be expected in as-cast hole size and shape over the full life cycle of a high pressure die casting die was established in previous work completed by Pacific Northwest National Laboratory, (PNNL). This established range of variation was captured in a set of 12 cast bosses by designing core pins at the size and draft angles identified in the sited previous work. The cast bosses were cut into nuts that could be used in the Ford Fastener Laboratory test-cell to measure clamp load when a thread forming fastener was driven into a cast nut. There were two sets of experiments run. First, a series of cast aluminum nuts were made reflecting the range of shape and size variations to be expected over the life cycle of a die casting die. Taptite thread forming fasteners, (a widely used thread forming fastener suitable for aluminum applications), were driven into the various cored, as-cast nuts at a constant input torque and resulting clamp loads were recorded continuously. The clamp load data was used to determine the range of clamp loads to be expected. The bolts were driven to failure. The clamp load corresponding to the target input of 18.5 Nm was recorded for each fastener. In a like fashion, a second set of experiments were run with cast magnesium nuts and ALtracs thread forming fasteners, (a widely used thread forming fastener suitable for magnesium applications). Again all clamp loads were recorded and analyzed similarly to the Taptites in aluminum cast nuts. Results from previous work performed on the same test cell for a Battelle project using standard M8 bolts into standard M8 nuts were included as a comparator for a standard bolt and nut application. The results for the thread forming fasteners in aluminum cast holes were well within industry expectations of +/- 30% for out of the box and robustness range testing. The results for the dry and lubed extreme conditions were only slightly higher than industry expectations at +/- 35.6%. However, when compared to the actual Battelle results (+/- 40%) for a standard bolt and nut the tread forming fasteners performed slightly better. The results for the thread forming fasteners in magnesium cast holes were all well within industry expectations of +/- 30% for all three conditions. The robustness range (.05mm larger and smaller holes than the expected wear pattern of a die casting die at full life cycle) results also fell within the industry expectations for standard threaded fasteners. These results were very encouraging. It was concluded that this work showed that clamp load variation with thread forming fasteners is consistent with industry expectations for standard steel bolts and nuts at +/- 30%. There does not appear to be any significant increase in clamp load variation due to the application of thread forming fasteners in as-cast holes of aluminum or magnesium over the effective life of a die casting mold. The fully implemented potential benefit of thread forming fasteners in as-cast holes of aluminum and magnesium is estimated to be 6 trillion Btu per year for North America. Economic benefit is estimated to be nearly $800 million per year. Environmental benefits and quality improvements will also result from full implementation of this technology.

36 MATERIALS SCIENCE↗

Sci—Thur AM: YIS - 11: Estimation of Bladder-Wall Cumulative Dose in Multi-Fraction Image-Based Gynaecological Brachytherapy Using Deformable Point Set Registration

Dosimetric parameters based on dose-volume histograms (DVH) of contoured structures are routinely used to evaluate dose delivered to target structures and organs at risk. However, the DVH provides no information on the spatial distribution of the dose in situations of repeated fractions with changes in organ shape or size. The aim of this research was to develop methods to more accurately determine geometrically localized, cumulative dose to the bladder wall in intracavitary brachytherapy for cervical cancer. The CT scans and treatment plans of 20 cervical cancer patients were used. Each patient was treated with five high-dose-rate (HDR) brachytherapy fractions of 600cGy prescribed dose. The bladder inner and outer surfaces were delineated using MIM Maestro software (MIM Software Inc.) and were imported into MATLAB (MathWorks) as 3-dimensional point clouds constituting the “bladder wall”. A point-set registration toolbox for MATLAB, Coherent Point Drift (CPD), was used to non-rigidly transform the bladder-wall points from four of the fractions to the coordinate system of the remaining (reference) fraction, which was chosen to be the emptiest bladder for each patient. The doses were accumulated on the reference fraction and new cumulative dosimetric parameters were calculated. The LENT-SOMA toxicity scores of these patients were studied against the cumulative dose parameters. Based on this study, there was no significant correlation between the toxicity scores and the determined cumulative dose parameters.

60 APPLIED LIFE SCIENCES↗

Methodology to Generate the Decay Gamma Source for a Second Target Station Target Wedge

This report details the specifics of applying the Position-Averaged Method methodology for the calculation of the rotating lasagna-style target wedge activation and the resulting decay gamma source terms. The methodology uses MCNP® Code Version 6.2.0 with the RNUCS patch coupled with CINDER2008 from the AARE V1.0 package. The process begins with model preparations that include ensuring impurities are included in the materials in the regions of interest along with segmentation of the geometry in order to capture the decay gamma source gradients. This report also details the physics models and other MCNP®, CINDER2008, and ADVANTG 3.2.0 related options used to calculate the decay gamma source terms. ADVANTG 3.2.0 is used to generate a weight window set to aid in convergence of the neutron fluxes in the initial MCNP® protons-on-target particle transport calculation to calculate the neutron fluxes and spallation products in the regions of interest. The neutron fluxes and spallation products are then used in the CINDER2008 transmutation calculation, and the decay gamma sources are generated by the AARE_GAMMA_SOURCE_SCRIPT as a part of the AARE V1.0 package. These decay gamma sources include the energy distributions as well as the necessary distributions to sample the location of the source using the cell rejection method. The gamma sources that are produced using the methodology may be used for a wide variety of analysis involving the target wedge. This report includes the material specifications, physics options, proton source term description, geometrical configuration, and post-processing details.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Secondary neutron yields from thick-target GCR accelerator experiments - 25434

This work overviews recent experiments conducted at the NASA Space Radiation Laboratory which sought to experimentally verify model predictions of an optimal spacecraft shielding thickness and provide data which can be used to quantify uncertainties in the physics models within the standard particle transport codes which presently, in some places, poorly predict data and whose results can vary significantly from code to code. Now that the multi-year experiment campaign is complete, some of the overarching trends in the data can be studied; though this work only provides a cursory look at these overarching trends. A small set of the neutron yields measured in these experiments are showcased here. The experiment employed two thick targets along a beamline to emulate the walls of a spacecraft being bombarded by galactic cosmic rays. Time-of-flight techniques were used to characterize neutrons produced in the upstream target while a novel pulse height deconvolution methodology was developed and implemented to characterize neutrons produced in the downstream target. (authors)

43 PARTICLE ACCELERATORS↗

Characterization of Hanford LAW Phase 3 Glasses

This report provides analyses of glass compositions, wash solution compositions, and Product Consistency Test (PCT) leachate compositions for a series of simulated low-activity waste (LAW) glasses fabricated at the Pacific Northwest National Laboratory (PNNL). These data will be used in the development of improved property/composition models for LAW glass at Hanford. Chemical analyses were performed on a representative sample of each of the quenched and sulfur saturated glasses to allow for comparisons with the targeted compositions. For some of the quenched glasses, measured concentrations of Cr 2 O 3 , K 2 O, Na 2 O, P 2 O 5 , and ZrO 2 were below the targeted values. For some of the sulfur saturated glasses, the measured concentrations of Al 2 O 3 , Cl - , Cr 2 O 3 , F - , K 2 O, Na 2 O, P 2 O 5 , V 2 O 5 , and ZrO 2 were generally low relative to the targeted values. A comparison of the measured compositions of the quenched and sulfur saturated versions of the study glasses showed that the measured concentrations of Al 2 O 3 , Cl - , and F - were lower for most of the sulfur saturated glasses. The measured Cr 2 O 3 and K 2 O concentrations were markedly lower for the sulfur saturated versions of the glasses as compared to the quenched versions, which may indicate that these elements partitioned to the soluble sulfur salts. A set of modified glasses was received from PNNL later in this study. Chemical analysis showed that these glasses generally met their targeted compositions. The measured SO 3 concentrations were higher for most of the sulfur saturated glasses relative to those of the quenched versions, as expected. Chemical analysis of the wash solutions that resulted from preparation of the sulfur saturated melts identified Cr, K, Na, P, S, and V as the major elements in solution. With the exception of sulfur, this may explain why the measured concentrations of these components in the study glasses were generally below the targeted values. PNNL performed PCTs on quenched and canister centerline cooled (CCC) versions of the study glasses, as well as the modified glasses. The leachates were sent to SRNL for chemical analysis. Minor scatter in the measured values among the triplicate samples for each glass was noted, with significant differences among the triplicate values noted for four of the CCC glasses. Normalized concentration values for some of the study glasses were greater than the 100 g/L maximum (total dissolution), which may indicate an error in the test. It is recommended that PNNL review the performance of the PCTs to determine the cause of these potential outliers and errors. Revision 1 of this report: Corrects an issue with high chromium measurements for the Mod glass compositions and the second set of PCT leachates, Adds data for the Mod glass wash solutions that were unintentionally omitted, Corrects an issue with rounding of the targeted Al 2 O 3 concentrations in the study glasses

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The scoping, design, and plasma physics optimization of the Eos neutron source stellarator

On the path to a fusion pilot plant, Thea Energy plans to build Eos, a sub-breakeven, deuterium-deuterium, beam-target fusion, stellarator neutron source facility for producing tritium and other valuable radioisotopes. In this paper, a set of 1D plasma physics models are coupled and used to design the operating point of the facility and predict performance. At this foundational stage of the design, analytic and approximate models are sufficient to capture the leading-order effects, and fast enough to run in the inner loop of an optimizer. Higher-fidelity analyses will follow. Models of 1D profile-dependent neutral beam stopping, ion beam slowing down, beam-target fusion, electron-ion classical heat transfer, energy confinement (ISS04), beam pressure, beam heating of ions and electrons, beam-beam fusion fraction, and neutral beam injection and gyrotron heating electrical efficiencies are included. A numerical optimizer is used to determine the minimum required facility electric power to generate tritium at a given rate. A potentially advantageous regime is described in which modern precisely-quasisymmetric stellarators, new high-temperature superconductors, ITER-derived neutral beam injection, and new high-frequency gyrotrons enable a suitible target plasma with hot electrons, cold ions, peaked density and temperature profiles, and high beam-injected ion density. It appears possible at this time for a facility with a medium-scale and medium-strength stellarator whose required facility electric power is less than 40 MW to produce $2.5\times 10^{17}$ neutrons s -1 for the production of radioisotopes. With the addition of a tritium breeding blanket, such a facility could produce 0.2 grams d -1 or 70 grams yr -1 of tritium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Axiom System for Sequence-Based Specification

This paper establishes an axiomatic foundation and a representation theorem for the rigorous, constructive process, called sequence-based specification, of deriving precise specifications from ordinary (informal) statements of functional requirements. The representation theorem targets a special class of Mealy state machines, and algorithms are presented for converting from the set of sequences that define the specification to the equivalent Mealy machine, and vice versa. Since its inception, sequence-based specification has been effectively used in a variety of real applications, with gains reported in quality and productivity. This paper establishes the mathematical foundation independently of the process itself.

99 GENERAL AND MISCELLANEOUS↗

SU-F-T-99: Data Visualization From a Treatment Planning Tracking System for Radiation Oncology

Purpose: A treatment planning process tracker database with input forms and a TV-viewable display webpage was developed and implemented in our clinic to collect time data points throughout the process. Tracking plan times is important because it directly affects the patient quality of care. Simply, the longer a patient waits after their initial simulation CT for treatment to begin, the more time the cancer has to progress. The tracker helps to drive workflow through the clinic, while the data collected can be used to understand and manage the process to find and eliminate inefficiencies. Methods: The overall process steps tracked are CT-simulation, mark patient, draw normal contours, draw target volumes, create plan, and review/approve plan. Time stamps for task completion were extracted and used to generate a set of clinic metrics, among which include average time for each step in the process split apart by type of treatment, average time to completion for plans started in a given week, and individual overall completion time per plan. Results: Trends have been tracked for fourteen weeks of clinical data (196 plans). On average, drawing normal contours and target volumes is taking 2–5 times as long as creating the plan itself. This is potentially an issue because it could mean the process is taking too long initially, and it could be forcing the planning step to be done in a short amount of time. We also saw from our graphs that there appears to be no clear trend on the average amount of time per plan week-to-week. Conclusion: A tracker of this type has the potential to provide insight into how time is utilized in our clinic. By equipping our dosimetrists, radiation oncologists, and physicists with individualized metric sets, the tracker can help provide visibility and drive workflow. Funded in part by CPRIT (RP140105).

60 APPLIED LIFE SCIENCES↗

Assess and Benchmark Magneto-Inertial Fusion (MIF) Scaling. Final Technical Report for the SNL/Rochester ALPHA Follow-on Project

This project was a follow-on to the Sandia National Laboratories (SNL) and the Laboratory for Laser Energetics (LLE) ARPA-E ALPHA project entitled “Demonstrating Fuel Magnetization and Laser Heating Tools for Low-Cost Fusion Energy”. The primary purpose of this follow-on project was to obtain additional data at the OMEGA facility to help better understand how MagLIF, a platform that has already demonstrated the scientific viability of magneto-inertial fusion, scales across a factor of 1000 in driver energy. A secondary aspect of this project was to extend simulations and analysis at SNL to cover a wider magneto-inertial fusion (MIF) parameter space and test scaling of those models across this wide range of input energies and conditions of the target. This work was successful in improving understanding of how key physics elements of MIF scales and improves confidence in setting requirements for fusion gain with larger drivers. The OMEGA experiments at the smaller scale verified the hypothesis that preheating the fuel plays a significant role in introducing wall contaminants that mix into the fuel and significantly degrade fusion performance. This contamination not only impacts target performance but the optimal input conditions for the target. However, analysis at the Z-scale showed that target performance at high preheat levels is limited by the Nernst effect, which advects magnetic flux from the hot spot, reducing magnetic insulation and consequently reduces the temperature of the fuel. The combination of MagLIF experiments at the disparate scales of OMEGA and Z along with a multiscale 3D simulation analysis has led to new insight into the physical mechanisms responsible for limiting target performance and provides important benchmarks to assess target scaling more generally for MIF schemes. Finally, in addition to the MagLIF related work, a semi-analytic model of liner driven Field Reversed Configuration (FRC) was developed that predicts the fusion gain for such systems. This model was also validated with 2D radiation magneto-hydrodynamic simulations and predicts that fusion gains of near unity could be driven by the Z machine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physiological Factors Contributing to Postflight Changes in Functional Performance

Astronauts experience alterations in multiple physiological systems due to exposure to the microgravity conditions of space flight. These physiological changes include sensorimotor disturbances, cardiovascular deconditioning and loss of muscle mass and strength. These changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on lunar and Martian surfaces. To date, changes in functional performance have not been systematically studied or correlated with physiological changes. To understand how changes in physiological function impact functional performance an interdisciplinary pre/postflight testing regimen (Functional Task Test, FTT) has been developed that systematically evaluates both astronaut postflight functional performance and related physiological changes. The overall objectives of the FTT are to: Develop a set of functional tasks that represent critical mission tasks for Constellation. Determine the ability to perform these tasks after flight. Identify the key physiological factors that contribute to functional decrements. Use this information to develop targeted countermeasures. The functional test battery was designed to address high priority tasks identified by the Constellation program as critical for mission success. The set of functional tests making up the FTT include the: 1) Seat Egress and Walk Test, 2) Ladder Climb Test, 3) Recovery from Fall/Stand Test, 4) Rock Translation Test, 5) Jump Down Test, 6) Torque Generation Test, and 7) Construction Activity Board Test. Corresponding physiological measures include assessments of postural and gait control, dynamic visual acuity, fine motor control, plasma volume, orthostatic intolerance, upper and lower body muscle strength, power, fatigue, control and neuromuscular drive. Crewmembers will perform both functional and physiological tests before and after short (Shuttle) and long-duration (ISS) space flight. Data will be collected on R+0 (Shuttle only), R+1, R+6 and R+30. Using a multivariate regression model we will identify which physiological systems contribute the most to impaired performance on each functional test. This will allow us to identify the physiological systems that play the largest role in decrement in functional performance. Using this information we can then design and implement countermeasures that specifically target the physiological systems most responsible for the altered functional performance associated with space flight.

Bloomberg, J. J.↗

Probabilistic Classification Using Elemental Abundance Distributions and Lossless Image Compression in Apollo 17 Lunar Dust Samples from Mare Serenitatis

We have previously outlined a strategy for the detection of fossils [Storrie-Lombardi and Hoover, 2004] and extant microbial life [Storrie-Lombaudi and Hoover, 20051 during robotic missions to Mars using co-registered structural and chemical signatures. Data inputs included image lossless compression indices to estimate relative textural complexity and elemental abundance distributions. Two exploratory classification algorithms (principal component analysis and hierarchical cluster analysis) provide an initial tentative classification of all targets. Nonlinear stochastic neural networks are then trained to produce a Bayesian estimate of algorithm classification accuracy. The strategy previously has been successful in distinguishing regions of biotic and abiotic alteration of basalt glass from unaltered samples. [Storrie-Lombardi and Fisk, 2004; Storrie-Lombardi and Fisk, 2004] Such investigations of abiotic versus biotic alteration of terrestrial mineralogy on Earth are compromised by .the difficulty finding mineralogy completely unaffected by the ubiquitous presence of microbial life on the planet. The renewed interest in lunar exploration offers an opportunity to investigate geological materials that may exhibit signs of aqueous alteration, but are highly unlikely to contain contaminating biological weathering signatures. We here present an extension of our earlier data set to include lunar dust samples obtained during the Apollo 17 mission. Apollo 17 landed in the Taurus-Littrow Valley in Mare Serenitatis. Most of the rock samples from this region of the lunar highlands are basalts comprised primarily of plagioclase and pyroxene and selected examples of orange and black volcanic glass. SEM images and elemental abundances (C6, N7, O8, Na11, Mg12, Al13, Si14, P15, S16, Cll7, K19, Ca20, Fe26) for a series of targets in the lunar dust samples are compared to the extant cyanobacteria, fossil trilobites, Orgueil meteorite, and terrestrial basalt targets previously discussed. The data set provides a first step in producing a quantitative probabilistic methodology for geobiological analysis of returned lunar samples or in situ exploration.

Storrie-Lombardi, Michael C.↗

The NANOGrav 11yr Data Set: Limits on Supermassive Black Hole Binaries in Galaxies within 500 Mpc

Supermassive black hole binaries (SMBHBs) should form frequently in galactic nuclei as a result of galaxy mergers. At subparsec separations, binaries become strong sources of low-frequency gravitational waves (GWs), targeted by Pulsar Timing Arrays. We used recent upper limits on continuous GWs from the North American Nanohertz Observatory for Gravitational Waves (NANOGrav) 11 yr data set to place constraints on putative SMBHBs in nearby massive galaxies. We compiled a comprehensive catalog of ∼44,000 galaxies in the local universe (up to redshift ∼0.05) and populated them with hypothetical binaries, assuming that the total mass of the binary is equal to the SMBH mass derived from global scaling relations. Assuming circular equal-mass binaries emitting at NANOGrav's most sensitive frequency of 8 nHz, we found that 216 galaxies are within NANOGrav's sensitivity volume. We ranked the potential SMBHBs based on GW detectability by calculating the total signal-to-noise ratio such binaries would induce within the NANOGrav array. We placed constraints on the chirp mass and mass ratio of the 216 hypothetical binaries. For 19 galaxies, only very unequal-mass binaries are allowed, with the mass of the secondary less than 10% that of the primary, roughly comparable to constraints on an SMBHB in the Milky Way. However, we demonstrated that the (typically large) uncertainties in the mass measurements can weaken the upper limits on the chirp mass. Additionally, we were able to exclude binaries delivered by major mergers (mass ratio of at least 1/4) for several of these galaxies. We also derived the first limit on the density of binaries delivered by major mergers purely based on GW data.

Zaven Arzoumanian↗

Record magnetic field generation by short-pulse laser-driven capacitor-coil targets

Magnetic fields generated by capacitor-coil targets driven by intense short-pulse lasers have been characterized using ultrafast proton radiography. A 1-kJ, 15-ps laser at a center wavelength of 1053 nm irradiated the back plate of the capacitor with an intensity of ∼8.3 × 10 18 W/cm 2 , creating ultra large currents in the connecting coils. High-quality proton data obtained in the axial probing geometry show definitive signatures of magnetic field generation, allowing precision measurement of the field distribution and strength. The data show a coil current of 120 ± 10 kA producing 200 ± 20 Tesla magnetic fields at the coil center at 1.127 ns after the laser drive. In conclusion, this sets a record for magnetic field generation by the short-pulse-powered capacitor-coil targets.

Gao, Lan [Princeton Plasma Physics Laboratory (PPP↗