Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Evaluation the Geotech GS-13BH Borehole Seismic Sensor

Sandia National Laboratories has tested and evaluated the Geotech GS-13BH borehole sensor. The sensor provides a response similar to that of the standard GS-13 short-period seismic sensor intended for pier-installations in a borehole package. The purpose of this seismometer evaluation was to determine a measured sensitivity, amplitude and phase response, self-noise and dynamic range, passband and acceleration response of its calibration coil.

47 OTHER INSTRUMENTATION↗

Integration of Next Generation Critical Infrastructure Sensor Technologies

This project is focused on advancing current protective relaying and control through verifying next generation timing systems and sensors with current commercial off the shelf protective relays. This will further research in the field of advanced grid modernization and demonstrate interoperability between nextgeneration protective relays and voltage and current sensors. These commercial off the shelf (COTS) technologies were tested and integrated with next generation sensor technologies, with the results documented below.

47 OTHER INSTRUMENTATION↗

Sensor Selection for MIMO Vibration [Slides]

Objectives: Introduce a sensor selection approach to assist test engineers with MIMO test design. Demonstrate the capability of the approach. Approach: Define a desired response from a field model. Supply the sensor selection technique to two lab models, with different boundary conditions than the “field” model. Compare the laboratory response to the field response using sensors selected from the approach.

42 ENGINEERING↗

Sensor Selection for MIMO Vibration: Summary Slides [Slides]

Summary: Sensor selection approach for MIMO testing was defined and demonstrated on a model of a practical system. Laboratory response obtained using the approach matched the field response well. Information about how many control sensors, and where to locate sensors can be gleaned from the approach.

42 ENGINEERING↗

2022 MB3a Infrasound Sensor Type Approval Evaluation

Sandia National Laboratories has tested and evaluated an updated version of the MB3a infrasound sensor, designed by CEA and manufactured by SeismoWave. The purpose of this infrasound sensor evaluation is to measure the performance characteristics in such areas as power consumption, sensitivity, full scale, self-noise, dynamic range, response, passband, sensitivity variation due to changes in barometric pressure and temperature, and sensitivity to acceleration. The MB3a infrasound sensors are being evaluated for use in the International Monitoring System (IMS) of the Preparatory Commission to the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗

2022 Chaparral 64S Infrasound Sensor Type Approval Evaluation

Sandia National Laboratories has tested and evaluated a new version of the Chaparral 64S infrasound sensor, designed and manufactured by Chaparral Physics. The purpose of this infrasound sensor evaluation is to measure the performance characteristics in such areas as power consumption, sensitivity, full scale, self-noise, dynamic range, response, passband, sensitivity variation due to changes in barometric pressure and temperature, and sensitivity to acceleration. The Chaparral 64S infrasound sensors are being evaluated for use in the International Monitoring System (IMS) of the Preparatory Commission to the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗

Development of Quality Control Methods for Robust and Reliable Sensor Design

The successful adoption of additive manufacturing for the rapid prototyping of printed sensors requires the establishment of quantifiable metrics that can interrogate device performance. One measure of performance is the adhesion strength between the substrate and sensor interface, which is critical since the strength of this interface can dictate the accuracy and reliability of the printed sensor. In this work, a non-contact laser-induced spallation technique was used to quantify the adhesion of silver prints on an aluminum alloy substrate. The laser-based method was compared to a standardized pull-off adhesion test, which provided baseline measurements of adhesion strength. The sintering conditions were shown to play an important role in the film-substrate adhesion strength, as well as the cohesion and ductility of the film itself. The methods and results described in this work supports the establishment of process control steps that are necessary for verifying the reliability of printed devices prior to its deployment in critical experiments.

36 MATERIALS SCIENCE↗

Eddy Current Lift-Off Sensor Model

Eddy current sensors measure the lift-off or distance between the sensor head and a conducting surface. The sensor consists of a conducting coil carrying an alternating electrical current. By Faraday’s Law, a magnetic field is generated within the coil. This field induces electrical current loops within the conducting surface which in turn generate a magnetic field. This induced magnetic field opposes the coil magnetic field and thus, the current in the coil. This reduces the inductance of the coil while increasing its resistance. The strength of the induced magnetic field and consequently the coil inductance are proportional to the lift-off of the coil from the surface. Thus, a measurement of the coil inductance may yield a measure of the lift-off.

42 ENGINEERING↗

Report of METL Mutual Inductance Level Sensor Development for Use in Liquid Metals – FY2023

A robust mutual inductance level sensor (MILS) for use in high temperature liquid metals has been developed at Argonne National Laboratory (ANL). The current design utilizes mineral insulated cables with a 300-series stainless steel sheath, magnesium oxide insulation, and a single copper conductor. Two coils are wrapped on a common core made of a 300-series stainless steel tube. One coil is energized with an alternating current (AC) source, and this electromagnetically couples with the second coil to generate an induced voltage. The voltage is measured to determine the mutual induction between the coils, and the mutual inductance measurement can be used to determine the level of a nearby liquid metal volume. The MILS can be located in an isolating thimble that is fully sealed to a vessel containing liquid metal for ease of maintenance and replacement. When the primary coil is energized with the AC source, the coil not only electromagnetic (EM) couples with the second coil, but also the surrounding liquid metal. The EM coupling with the surrounding liquid metal reduces the EM coupling with the second coil, producing an inverse-linear relationship between liquid metal level and secondary coil voltage. This has all been demonstrated at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at ANL. The most current iteration of the MILS system is the MILS-MK-II. This sensor system has been commissioned in a non-sodium test stand where calibrations were performed using a sodium analog. The calibrations proved to be highly linear and repeatable. The MILS-MK-II has been installed in the METL expansion tank where high temperature sodium tests have been performed. The MILS-MK-II has been calibrated against a known standard at temperature of 300°C, and the calibrations have proved to be highly linear and repeatable. The calibrated MILS-MK-II has been in operation in the METL facility for several thousands of hours at temperatures around 300°C. The experimental data has been used to develop and validate electromagnetic finite element models in COMSOL Multiphysics, and now these models can be used to advance the development of the sensor system. Next steps will include temperature compensation to allow for operation at various temperatures. Additionally, efforts to incorporate a self-calibration methodology are underway.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetostrictive materials for enhanced sensors and electronic components

Magnetostriction is a property of magnetic materials that causes them to change their shape or dimensions proportional to their magnetization. Low-cost, mechanically robust magnetostrictive sensors would be valuable for a wide range of applications across the DOE and national security mission space, such as monitoring the internal conditions of pipelines, rapidly detecting high-impedance faults in power lines (e.g. trees touching power lines), or enhancing implantable systems for the human body. Dilute doping (<1 at.%) of rare earth elements (REE) has been shown to amplify the magnetostriction. Furthermore, alloy processing by rapid cooling from high temperature tends to result in texturing and therefore greater magnetostriction values, which bodes well for developing advanced manufacturing approaches significantly less expensive than single crystal growth. The goal of this effort was to develop robust, low-cost magnetostrictive materials compatible with advanced manufacturing techniques to exploit the rapid cooling of these approaches while retaining the ability to produce fully dense structures. To be useful as a sensor or actuator the coercivity of the material needs to be minimized so that there is minimal magnetic hysteresis. Employing a small scale laser powder bed fusion (L-PBF) system, specimens of Fe-Ga-Ce were built from alloy powder which had a magnetostriction of 289 ppm along the build direction and 197 ppm perpendicular to the build direction. These values are not far from the 310-350 ppm observed in single crystals of Fe-Ga. The results of the series of samples run suggest this is a very promising route for REE doping to higher levels, especially if the powders can be produced using far from equilibrium approaches such as ultrasonic atomization. The promising results from applying additive manufacturing techniques to these materials, particularly the inexpensive Fe-Al system, has potential for inexpensive high-performing magnetostrictive parts producible at large scales for low-cost sensors.

36 MATERIALS SCIENCE↗

Development of CMOS Sensors for HEP with a US-based foundry

We will present a program to establish the first development and manufacturing of HEP-specific sensors monolithically integrated into a standard CMOS process using a US-based foundry. In collaboration with several US universities the project aims to develop Monolithic Active Pixel Sensors (MAPS) designs implemented in the 90 nm technology node, including simple test structures and multi-pixel arrays, and monolithic CMOS sensors with readout integrated circuits, perform detailed characterization of the detector prototypes and quantify their performance for HEP applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine Learning Enabled Sensor Fusion for In-Situ Defect Detection in Laser Powder Bed Fusion

Laser Powder Bed Fusion (L-PBF) Additive Manufacturing (AM) is among the metal 3D printing technologies most broadly adopted by the manufacturing industry. The current industry qualification paradigm for critical-application L-PBF parts relies heavily on expensive non-destructive inspection techniques such as X-Ray Computed Tomography (XCT), which significantly limits the use-cases of L-PBF. In situ monitoring of the process promises a less expensive alternative to ex situ testing, but existing sensor technologies and data analysis techniques struggle to detect sub-surface flaws (e.g., porosity and cracking) on production-scale L-PBF printers. RTX Technologies Research Center (RTRC) has licensed ORNL’s Peregrine software package – a printer- and camera-agnostic data analytics tool designed specifically for detecting process anomalies using in situ data collected during powder bed printing. The goal of this project was to feed temporally rich, multi-modal sensor data, including visible light, integrated near infrared (NIR), and spatially mapped co-axial melt pool thermal emission data into Peregrine to enable detection of subsurface flaws. XCT data was used as ground truth training data to allow Peregrine’s deep learning algorithms to recognize anomalies in these complex data streams in both test artifacts and industrially relevant geometries. Completion of this program has seen the successful implementation of multi-modal, multi-layer sensor data footprints for training of machine learning models in Peregrine. Flaws detected in XCT data have been successfully detected directly from this in situ data footprint, and initial analyses of the in situ probability-of-detection has been conducted, showing performance levels commensurate with traditional non-destructive evaluation (NDE) methods. The in situ monitoring methodology was then applied to an industrially relevant component that was using post-build NDE, highlighting the utility of the proposed method for hard-to-inspect AM components. As a direct result of this program, two journal manuscripts [1], [2] have been published in Additive Manufacturing, with additional manuscripts planned following program completion.

36 MATERIALS SCIENCE↗

Test Beam Results of Planar Pixel Sensor for the CMS Phase 2 Inner Tracker Upgrade

Results of the test beam measurements that characterise the performance of CMS Readout Chip (CROC) sensors to be used in the High Luminosity era of the Large Hadron Collider (HL-LHC) are presented. The HL-LHC peak instantaneous luminosity of $7.5 \times 10^{34} \ \text{cm}^{-2} s^{-1}$ corresponds to an average of around 200 inelastic proton-proton collisions per beam-crossing every 25 ns. In order to efficiently reconstruct and track particles in this extreme and challenging conditions, the present CMS tracking detector will be completely replaced. The new tracking detector consists of an Inner Tracker closest to the beamline and an Outer Tracker surrounding it. These are populated with modules that comprise of readout chips and silicon sensors. The test beam measurements of these modules are vital to understand the performance of the related technologies. Using a primary 120 GeV proton beam from the Main Injector at Fermilab, data was collected at the Fermilab Test Beam Facility (FTBF) using the silicon tracker telescope that provides a precision position measurement of the track impact point with less than 5 $\mu$m uncertainty. The proton beam was incident on a 1x2 planar CROC module developed by Hamamatsu. The sensor has 100x25 $\mu m^2$ standard pixels and also a smaller number of 225x25 $\mu m^2$ longer pixels at the boundary between the two ROCs. We present characterization of these modules that includes pixel efficiency, resolution, cluster size and charge distributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pragmatic Uncertainty Quantification and Propagation in Inverse Estimation of Structural Dynamics Parameters given Material Property Uncertainties and Limited Sensor Data

In this report we demonstrate some relatively simple and inexpensive methods to effectively account for various sources of epistemic lack-of-knowledge type uncertainty in inverse problems. The demonstration problem involves inverse estimation of six parameters of a bolted joint that attaches a kettlebell shaped object to a thick plate. The parameters are efficiently inverted in a modal-based model calibration using gradient-based optimization. Two material properties of the kettlebell are treated as uncertain to within given epistemic uncertainty bounds. We apply and test interval and sparse-sample probabilistic approaches to account for uncertainty in the estimated parameters (and various scalar functionals of the parameters as generic quantities of interest, QOIs) due to uncertainties in the material properties. We also investigate the error effects of limited numbers of vibration sensors (accelerometers) on the kettlebell and plate, and therefore abbreviated excitation/response information in the parameter inversions. We propose and demonstrate a Leave-K-Sensors-Out “cross-prediction” UQ approach to estimate related uncertainties on the parameters and QOI functionals. We indicate how uncertainties from material properties and limited sensors are treated in a combined manner. The economical combined UQ approach involves just three to five samples (i.e. three to five inverse simulations), with no added complication or error/uncertainty from use of surrogate models for affordability. Finally, we describe a related economical UQ approach for handling potential parameter solution non-uniqueness and numerical optimization related precision uncertainties in the estimated parameter values. Indicated further research is identified.

36 MATERIALS SCIENCE↗

Final Report on Characterization of Irradiated Sensors and Coupling Adhesive Bonds

This report summarizes characterization via scanning/transmission electron microscopy of the microstructures of the unirradiated and irradiated piezoelectric ultrasonic sensor/aluminum substrate assemblies using four commercially available inorganic coupling adhesives to bond two types of piezoelectric crystals to the substrates. The sample assemblies were irradiated in the PULSTAR reactor at NC State University and ultrasonic data was collected in-situ. ORNL LAMDA Laboratory capabilities were utilized to perform pre- and post-irradiation examination of the sensor assemblies. This document summarizes the PIE performed at the ORNL LAMDA laboratory. The results of the PIE described in this report are consistent with the ultrasonic data collected during irradiation – in particular, high temperature epoxy adhesive seemed to provide the best coupling as compared to the refractory ceramic adhesives. It was determined that the quality of the sensor-adhesive-substrates governed the ultrasonic performance of the sensors. It was also apparent that irradiation did not significantly affect bond quality, which is also supported by the ultrasonic data collected during irradiation. A more comprehensive DOE NSUF Final Report including details of materials selection, sample fabrication, initial ultrasonic testing, irradiation and in-situ ultrasonic testing, positron annihilation lifetime spectroscopy and doppler broadening spectroscopy performed at EPRI and NC State University will be published at the conclusion of the project.

36 MATERIALS SCIENCE↗

Distributed Temperature Profiles of Silicon Carbide Catalyst Bed in a Microwave Reactor using Fiber-optic Sensor

Microwave heating is of great interest for reducing greenhouse gas emissions of catalytic chemical conversion processes because it can heat up the reactants rapidly and efficiently and accelerate reaction rates. In microwave-assisted catalytic thermochemical conversion processes, accurate internal temperature measurement would help facilitate effective process control. Metallic thermocouples interfere and spark in the microwave heating environment, so they are not an option. Infrared pyrometers typically provide a single temperature value by averaging over a finite surface area of the catalyst bed. In this work, we use fiber-optic sensors passing through the catalyst bed to provide more accurate temperatures along the height of the catalyst bed. The fiber optic sensors are immune to the electromagnetic microwave radiation and provide temperature profiles along their length. Here, custom fiber-optic sensors were coupled to the optical distributed temperature sensing devices to measure the temperature profiles along the height of the catalyst bed at high temperatures with ~1 mm spatial resolution. The sensing devices use optical frequency domain reflectometry (OFDR) technique for distributed temperature measurement. This work shows the temperature profiles along the height of the silicon carbide powder catalyst bed in the variable and fixed frequency microwave reactors.

Thapa, Juddha↗

Flow Sensor Test Article (F-STAr) - Water Testing and Commissioning Report for FY2024

Argonne National Laboratory’s Mechanism Engineering Test Loop (METL) facility is developing new experimental testing capabilities with the Flow Sensor Test Article (F-STAr). F-STAr’s mission is to provide high flowrate, sodium submersible testing capabilities to support the development of sodium cooled nuclear fission reactors. Figure 1 shows a model of F-STAr (left) and a photo of the partially assembled test article (right) with several of the main components labeled. The system currently includes a large pump with desired flowrates of up to 100 GPM; an immersion heater with a maximum power of 5 kW; an immersion cooler with an estimated maximum cooling power of 2 kW; and an experimental test section to support sub-test articles. Initially, F-STAr will be setup for testing flow sensors, specifically Eddy Current Flow Sensors (ECFS). However, the system can be reconfigured to support a wide range of testing needs. For example, F-STAr could be setup to complete testing of hydraulic components, heat exchangers, hydrodynamic bearings, seals, and more. This report will provide an update on the development of F-STAr with a focus on the water testing and commissioning activities during Fiscal Year 2024 (FY24). First, the report will focus on describing the pump development. Specifically, updates will be provided on troubleshooting the pump’s excessive vibrational issues. In addition to updates on the pump, pressure-flowrate performance testing in water will be described. Furthermore, updates will be provided on a pump shaft bushing development as well as rigging procedures. Future work and paths forward for F-STAr will be described. Finally, a short summary on the ECFS development will be described at the end of the report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Zero-Power Wireless Infrared Digitizing Sensors for Large Scale Energy-Smart Farm

This project, funded by ARPA-E and led by Northeastern University, developed zeropower infrared digitizing sensors to optimize irrigation and enhance crop yields. Traditional water stress detection methods are costly and require frequent maintenance, limiting their effectiveness. Our research identified shortwave infrared (SWIR) transmittance as the most reliable indicator of plant water stress and developed plasmonically enhanced micromechanical photoswitches (PMPs) that operate with minimal power. The sensors offer low-cost, large-scale deployment, auto-calibration across different crops, and a 10-year battery life, significantly reducing maintenance costs. The system achieved 4x greater accuracy than conventional soil moisture sensors while ensuring economic feasibility. By enabling precision irrigation, this technology conserves water, enhances crop productivity, and lowers operational costs, making it a scalable solution for sustainable agriculture and global food security.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗