Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reserve”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Valuation of Distributed Wind Turbines Providing Multiple Market Services

The role of wind turbines has traditionally been limited to providing energy capacity to the grid, but the availability of smart inverters and recent regulatory changes provide the technical and policy capability for wind turbines to also provide ancillary services. However, in contrast to the technical and policy aspects, the valuation of distributed wind turbines providing such services has not been thoroughly studied. This paper presents an optimal market-participation method for distributed wind turbines and valuates different strategies in California Independent System Operator’s balancing area. The services include energy capacity, regulation up and down, and reserves. An optimization problem is formulated to determine optimal power output for each service and demonstrated using historical data for one complete year. The revenues from multiple services are quantified, and a sensitivity analysis is performed to relate market prices with revenues. It is found that the optimal strategy generates 6% more revenue compared to the revenue from participating in the energy market only. Also, the reduced energy prices in future scenarios increase the relative importance of market participation in ancillary services.

Bhatti, Bilal Ahmad↗

Sizing Considerations for EV Dynamic Wireless Charging Systems with Integrated Energy Storage

Roadways with dynamic wireless charging systems (DWCS) enable charge-sustaining in-motion EV charging, which can reduce charging idle time while increasing range capabilities. Spatially distributed transmitter coils are controlled in response to traffic load that varies significantly minute to minute with high power levels, very short charging time, and low system utilization like wind turbine power. Traffic load estimation and localized analysis may guide effective sizing and topology adoption for feasible and scalable DWCS deployment. DWCS traffic load approximation is reviewed with measured Automated Traffic Recorder (ATR) data and statistical distributions being used to create a synthetic load analyzed using proposed metrics quantifying system utilization over time. Lumped coil section segmentation is compared between second-based distance and spatial density analysis methods, offering 17-27% greater system utilization. A peak load shifting method is proposed for traffic redirection across two tracks with optional BESS integration increasing system utilization by 50-60% depending on time-based and power reserve-based sizing and control.

Lewis, Donovin D.↗

An Uncertainty Management Framework for Integrated Gas-Electric Energy Systems

In many parts of the world, electric power systems have seen a significant shift toward generation from renewable energy and natural gas. Because of their ability to flexibly adjust power generation in real time, gas-fired power plants are frequently seen as the perfect partner for variable renewable generation. However, this reliance on gas generation increases interdependence and propagates uncertainty between power grids and gas pipelines and brings coordination and uncertainty management challenges. To address these issues, we propose an uncertainty management framework for uncertain, but bounded gas consumption by gas-fired power plants. The admissible ranges are computed based on a joint optimization problem for the combined gas and electricity networks, which involves chance-constrained scheduling for the electric grid and a novel robust optimization formulation for the natural-gas network. This formulation ensures feasibility of the integrated system with a high probability, while providing a tractable numerical formulation. A key advance with respect to existing methods is that our method is based on a physically accurate, validated model for transient gas pipeline flows. Our case study benchmarks our proposed formulation against methods that ignore how reserve activation impacts the fuel use of gas power plants and only consider predetermined gas consumption. Here, the results demonstrate the importance of considering uncertainty to avoid operating constraint violations and curtailment of gas to the generators.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MWm-array sensors for in situ monitoring of high-temperature components in power plants

Utilization of America's substantial coal reserves for energy production has become a national priority. Advanced coal-fired power plants offer an environmentally friendly means to achieve that goal. These power plants, such as ultrasupercritical power plants, will provide high thermal efficiency along with greatly reduced emissions of CO and other pollutants. Life cycle costs for the advanced coal-fired plants can be reduced by enhanced observability in support of condition-based maintenance. The enhanced observability can be achieved by using networks of condition-monitoring sensors that would provide component-level material condition information and through-wall temperature monitoring. This would reduce uncertainties in knowledge of material condition, at the level of individual components, and improve capability to predict remaining life of critical components. One approach being developed under the U.S. Department of Energy Small Business Innovation Research Program is to develop and implement high-temperature versions of the meandering winding magnetometer (HT-MWM) for temperatures up to 1000{sup o}C. These patented sensors, coupled with multivariate inverse methods, would provide superior performance for in situ material condition monitoring (material degradation, flaw detection, stress relaxation, and/or creep monitoring) and through-wall temperature measurement. Networks of HT-MWMs will generate material condition information to be used by adaptive life-management algorithms for remaining life prediction and decision support.

20 FOSSIL-FUELED POWER PLANTS↗

The COVID-19 High-Performance Computing Consortium

In March of 2020, recognizing the potential of High Performance Computing (HPC) to accelerate understanding and the pace of scientific discovery in the fight to stop COVID-19, the HPC community assembled the largest collection of worldwide HPC resources to enable COVID-19 researchers worldwide to advance their critical efforts. Amazingly, the COVID-19 HPC Consortium was formed within one week through the joint effort of the Office of Science and Technology Policy (OSTP), the U.S. Department of Energy (DOE), the National Science Foundation (NSF), and IBM to create a unique public–private partnership between government, industry, and academic leaders. This article is the Consortium's story–how the Consortium was created, its founding members, what it provides, how it works, and its accomplishments. We will reflect on the lessons learned from the creation and operation of the Consortium and describe how the features of the Consortium could be sustained as a National Strategic Computing Reserve to ensure the nation is prepared for future crises.

97 MATHEMATICS AND COMPUTING↗

Building Energy Systems as Behind-the-Meter Resources for Grid Services: Intelligent load control and transactive control and coordination

To mitigate the impacts of climate change, significant reductions in emissions from all sectors of the economy are needed. The electricity generation sector has embarked on an ambitious plan to include renewable generation as part of its decarbonization efforts, and many cities and states are mandating all-electric buildings. While renewable resources will reduce emissions, they are not dispatchable, they vary temporally, and their generation is uncertain. Under these conditions, traditional approaches to managing grid reliability, where supply follows demand, will not be efficient and may not be cost-effective. Further, there is a more efficient alternative for balancing the supply–demand imbalance and for absorbing variability and uncertainty of renewable energy using distributed energy resources (DERs) as opposed to reserve generation. Because buildings consume more than 75% of total U.S. annual electricity consumption, behind-the-meter (BTM) DERs have a load flexibility of 77 GW of power and 90 GWh of virtual energy storage capacity nationwide (Kalsi, 2017). Therefore, some portion of the supply–demand imbalance can be met by these DERs at a lower cost compared to business-as-usual solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchical Control of Grid-Connected Hydrogen Electrolyzer Providing Grid Services

This paper presents the operational modes and control architecture of the grid-connected hydrogen electrolyzer systems for the provision of frequency and voltage supports. The analysis is focused on the primary and secondary loops in the hierarchical control scheme. At the power converter inner control loop, the voltage- and current-control modes are analyzed. At the primary level, the droop and opposite droop control strategies to provide voltage and frequency support are described. Coordination between primary control and secondary, tertiary reserves is briefly discussed. The case studies and real-time hardware-in-the-loop simulation results are provided using Typhoon HIL to back the theoretical investigation.

ancillary services↗

GPU Direct I/O with HDF5

Exascale HPC systems are being designed with accelerators, such as GPUs, to accelerate parts of applications. In machine learning workloads as well as large-scale simulations that use GPUs as accelerators, the CPU (or host) memory is currently used as a buffer for data transfers between GPU (or device) memory and the file system. If the CPU does not need to operate on the data, then this is sub-optimal because it wastes host memory by reserving space for duplicated data. Furthermore, this “bounce buffer” approach wastes CPU cycles spent on transferring data. A new technique, NVIDIA GPUDirect Storage (GDS), can eliminate the need to use the host memory as a bounce buffer. Thereby, it becomes possible to transfer data directly between the device memory and the file system. This direct data path shortens latency by omitting the extra copy and enables higher-bandwidth. To take full advantage of GDS in existing applications, it is necessary to provide support with existing I/O libraries, such as HDF5 and MPI-IO, which are heavily used in applications. In this paper, we describe our effort of integrating GDS with HDF5, the top I/O library at NERSC and at DOE leadership computing facilities. We design and implement this integration using a HDF5 Virtual File Driver (VFD). The GDS VFD provides a file system abstraction to the application that allows HDF5 applications to perform I/O without the need to move data between CPUs and GPUs explicitly. We compare performance of the HDF5 GDS VFD with explicit data movement approaches and demonstrate superior performance with the GDS method.

Ravi, J↗

Recommended Practices for Wind Integration Studies

Many wind integration studies have been performed in recent years, with evolving methodologies. Since power systems and data availability vary significantly, the results and methodologies used in these studies have varied accordingly. This paper presents the main findings from the IEA WIND Recommended Practices for Wind Integration studies. An overview of a complete wind integration study is presented as a flow chart. The main simulation steps are presented with recommendations on methodologies: an increase in reserve requirements, estimating impacts on other generation and balancing, capacity value of wind power and transmission expansion due to wind power. The study set-up and the main assumptions are outlined, as they can have a critical impact on the results. The recommendations are applicable for other variable renewable sources, including photovoltaics.

load flow↗

Coordinated Integration of Renewable Generation and Small Modular Reactors in Puerto Rico – an Initial Study

With a growing interest and awareness to support clean and sustainable sources of energy, several countries have ambitious plans to significantly increase the penetration of renewable energy in the grid. However, the sources of renewable energy, such as solar and wind, are highly intermittent and therefore can pose additional challenges to maintain reliable system operations; one such challenge being flexibility requirement. This paper addresses the concerns of increasing flexibility needs with high renewable penetration, and also study the coordinated integration of nuclear small modular reactor and inverter-based renewable generation sources in a system to achieve high levels of carbon-free and sustainable energy. In this paper, balancing reserve and short-term flexibility requirements were considered for the analysis purpose. Also, methodology was developed to calculate metrics for calculating short-term flexibility requirements in the time-scale of hours. Small modular reactors are considered as potential sources of generation flexibility to complement renewables.

Agrawal, Urmila↗

A Novel Secondary Frequency Regulation with Optimal Priority Selection of AGC Contributions

Automatic generation control (AGC) is used to maintain acceptable frequencies during operation owing to fluctuations in load and variable resources. In conventional industry applications, the AGC signal is allocated to each generator according to the predispatched frequency regulation capacity or the order of economic efficiency. However, with the increasing integration of inverter-based resources (IBRs), the retirement of conventional synchronous generators (SGs) has posed new challenges to frequency control schemes because fewer of them are optional for AGC regulation. In this paper, we propose a novel model predictive control (MPC)-based frequency regulation model to reduce control cost and ensure stability, by considering different critical dynamic factors when optimally selecting the AGC units. The proposed control model – developed in a general form – comprehensively embeds characteristics such as generator ramping rates, reserve capacity, and operation cost. The model predictive control–based two-timescale AGC scheme enhances the capability of immunizing the power disturbance from types of resources by coordinating the control signals between faster IBRs and slower SGs. The case study’s proposed model is verified to be effective in synergistically enforcing different dynamic properties of AGC units into the frequency regulation scheme.

Jiang, Sufan [The University of North Carolina at ↗

Experiences Integrating Transmission and Distribution Simulations for DERs with the Integrated Grid Modeling System (IGMS)

This paper discusses the development of, approaches for, experiences with, and some results from a large-scale, high-performance-computer-based (HPC-based) co-simulation of electric power transmission and distribution systems using the Integrated Grid Modeling System (IGMS). IGMS was developed at the National Renewable Energy Laboratory (NREL) as a novel Independent System Operator (ISO)-to-appliance scale electric power system modeling platform that combines off-the-shelf tools to simultaneously model 100s to 1000s of distribution systems in co-simulation with detailed ISO markets, transmission power flows, and AGC-level reserve deployment. Lessons learned from the co-simulation architecture development are shared, along with a case study that explores the reactive power impacts of PV inverter voltage support on the bulk power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV Inverter Fault Response Including Momentary Cessation, Frequency-Watt, and Virtual Inertia

This paper presents two photovoltaic (PV) inverter control methods and an analysis of the two under a significant three-phase transmission line fault contingencies in the Hawaiian island of Oahu power system. Simulations are presented for the two control methods on the island power system with a high penetration of PV generation, approximately 40% of the total. The two control methods discussed are similar: one is a proportional frequency-watt controller, and the second is a proportional-derivative controller, a frequency-watt controller with virtual inertia. Both methods can be beneficial for fast frequency support. The inverter model also emulates inverter fault response including 'momentary cessation' and recovery during low voltage events. The study presented in this paper utilizes a validated power system model of the Hawaiian island of Oahu, modified to include PV resources with the two custom developed control models. Dynamic simulations with PSS/E are presented during a significant transmission line three-phase fault contingency. Simulations are presented with and without PV reserve margin. In addition, a parameter sensitivity analysis is presented for the control methods. Results indicate both methods can significantly improve system response during fault events. Findings indicate that transmission faults can produce severe frequency events, and that fast recovery from momentary cessation is crucial to mitigate severity.

14 SOLAR ENERGY↗

Advances and applications in low-power phased array X-band weather radars

Low-cost, low-power X-band phased array radar (LPAR) is an enabling technology for future deployment of distributed short-range radar networks. Such networks offer the potential for superior and lower altitude surveillance of atmospheric and airborne events compared with today's larger, long range national radar networks. Two dimensionally steered (phase-phase steering, without motors or other moving parts) phased array radars are complex systems comprising multiple subsystems including several thousand transmit/receive (T/R) channels, beam steering computers, thermal management. Owing to this complexity and the associated cost, phased array technology has not historically been used in weather and air traffic control radars. Competition for the frequency spectrum traditionally reserved for long-range radars is motivating the search for new approaches to national air surveillance; this has motivated R&D investment in two-dimensional X-band LPAR over the past decade, to the point where prototype systems are now emerging in several application settings including, for the first time, the university research setting. Two-dimensional high-speed (inertia-less) beam steering combined with dual polarization, programmable/adaptive waveforms, and the ability to combine multiple radars into networks is leading to new atmospheric science research opportunities related to hazardous storm forecasting and response, understanding cloud physics, water resource management, monitoring the movement and dispersal of hazardous plumes, and other areas.

54 ENVIRONMENTAL SCIENCES↗

Optimal Load-Side Control for Frequency Regulation in Smart Grids

Frequency control rebalances supply and demand while maintaining the network state within operational margins. It is implemented using fast ramping reserves that are expensive and wasteful, and which are expected to become increasingly necessary with the current acceleration of renewable penetration. The most promising solution to this problem is the use of demand response, i.e., load participation in frequency control. Yet it is still unclear how to efficiently integrate load participation without introducing instabilities and violating operational constraints. In this paper, we present a comprehensive load-side frequency control mechanism that can maintain the grid within operational constraints. In particular, our controllers can rebalance supply and demand after disturbances, restore the frequency to its nominal value, and preserve interarea power flows. Furthermore, our controllers are distributed (unlike the currently implemented frequency control), can allocate load updates optimally, and can maintain line flows within thermal limits. We prove that such a distributed load-side control is globally asymptotically stable and robust to unknown load parameters. We illustrate its effectiveness through simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Open-Source Tool for Automated Power Grid Stress Level Prediction at Balancing Authorities

The behavior of modern power systems becomes more stochastic and dynamic, due to the increased penetration of variable generation, demand response, new power market structure, extreme weather conditions, contingencies, and unexpected events. It is critically important to predict potential system operational issues so that grid planners and operators can take preventive actions to mitigate the impact, e.g., lack of operational reserves. In this paper, an innovative software tool is presented to assist power grid operators in a balancing authority (BA) to predict the grid stress level over the next operating day. It periodically collects necessary information from public domain such as weather forecasts, electricity demand, and automatically estimates the stress levels on a daily basis. Advanced Neural Network and regression tree algorithms are developed as the prediction engines to achieve this goal. The tool has been tested on a few key balancing authorities that successfully predicates the growing system peak load and increased stress levels under extreme heat waves in the United States of America.

Berscheid, Alan P.↗

Flexibility Options: A Proposed Product for Managing Imbalance Risk

The presence of variable renewable energy resources with uncertain outputs in day-ahead electricity markets results in additional balancing needs in real-time. Addressing those needs cost-effectively and reliably within a competitive market with unbundled products is challenging as both the demand for and the availability of flexibility depends on day-ahead energy schedules. Existing approaches for reserve procurement usually rely either on oversimplified demand curves that do not consider how system conditions that particular day affect the value of flexibility, or on bilateral trading of hedging instruments that are not co-optimized with day-ahead schedules. This article proposes a new product, ‘Flexibility Options', to address these two limitations. The demand for this product is endogenously determined in the day-ahead market and it is met cost-effectively by considering real-time supply curves for product providers, which are co-optimized with the energy supply. As we illustrate with numerical examples and mathematical analysis, the product addresses the hedging needs of participants with imbalances cost-effectively, provides a less intermittent revenue stream for participants with flexible outputs, promotes value-driven pricing of flexibility, and ensures that the system operator is revenue-neutral. This article provides a comprehensive design that can be further tested and applied in large-scale systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Transient Stability Analysis for Offshore Wind Power Plant Integration Planning Studies - Part I: Short Term Faults

Power system planning is the process of forecasting load demand and ensuring sufficient generation and reserve capacities over some planning horizon. This process includes investigation of steady-state and dynamic operation of power system of interest. This paper addresses the transient stability (also known as large-signal stability) analysis of power systems for offshore wind power plant integration planning studies. In particular, this study develops a comprehensive practical methodology to assess transient stability of power systems, including rotor angle stability, voltage stability and frequency response for all fault types for large scale power systems. This methodology considers variability of the offshore wind power plants as well as the type of any faulted components present and is applicable to the study of both short term and long term faults, though only short term faults are considered here (long term faults are treated sequentially in a companion paper). Furthermore, this paper considers the integration of offshore wind power plants into existing power systems and demonstrates the utility of this methodology through the examination of the specific case of integrating 1,000MW of offshore wind power into the FirstEnergy/PJM service territory using a realistic model of 63k-bus test system that represents the U.S. Eastern Interconnection.

17 WIND ENERGY↗