Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Surface applicator calibration and commissioning of an electronic brachytherapy system for nonmelanoma skin cancer treatment

Purpose: The Xoft Axxent x-ray source has been used for treating nonmelanoma skin cancer since the surface applicators became clinically available in 2009. The authors report comprehensive calibration procedures for the electronic brachytherapy (eBx) system with the surface applicators. Methods: The Xoft miniature tube (model S700) generates 50 kVp low-energy x rays. The new surface applicators are available in four sizes of 10, 20, 35, and 50 mm in diameter. The authors' tests include measurements of dose rate, air-gap factor, output stability, depth dose verification, beam flatness and symmetry, and treatment planning with patient specific cutout factors. The TG-61 in-air method was used as a guideline for acquiring nominal dose-rate output at the skin surface. A soft x-ray parallel-plate chamber (PTW T34013) and electrometer was used for the output commissioning. GafChromic EBT films were used for testing the properties of the treatment fields with the skin applicators. Solid water slabs were used to verify the depth dose and cutout factors. Patients with basal cell or squamous cell carcinoma were treated with eBx using a calibrated Xoft system with the low-energy x-ray source and the skin applicators. Results: The average nominal dose-rate output at the skin surface for the 35 mm applicator is 1.35 Gy/min with {+-}5% variation for 16 sources. The dose-rate output and stability (within {+-}5% variation) were also measured for the remaining three applicators. For the same source, the output variation is within 2%. The effective source-surface distance was calculated based on the air-gap measurements for four applicator sizes. The field flatness and symmetry are well within 5%. Percentage depth dose in water was provided by factory measurements and can be verified using solid water slabs. Treatment duration was calculated based on the nominal dose rate, the prescription fraction size, the depth dose percentage, and the cutout factor. The output factor needs to be measured for each case with varying shapes of cutouts. Conclusions: Together with TG-61, the authors' methodology provides comprehensive calibration procedures for medical physicists for using the Xoft eBx system and skin applicators for nonmelanoma skin cancer treatments.

60 APPLIED LIFE SCIENCES↗

Dose Escalation for Locally Advanced Lung Cancer Using Adaptive Radiation Therapy With Simultaneous Integrated Volume-Adapted Boost

Purpose: To test the feasibility of a planned phase 1 study of image-guided adaptive radiation therapy in locally advanced lung cancer. Methods and Materials: Weekly 4-dimensional fan beam computed tomographs (4D FBCT) of 10 lung cancer patients undergoing concurrent chemoradiation therapy were used to simulate adaptive radiation therapy: After an initial intensity modulated radiation therapy plan (0-30 Gy/2 Gy), adaptive replanning was performed on week 2 (30-50 Gy/2 Gy) and week 4 scans (50-66 Gy/2 Gy) to adjust for volume and shape changes of primary tumors and lymph nodes. Week 2 and 4 clinical target volumes (CTV) were deformably warped from the initial planning scan to adjust for anatomical changes. On the week 4 scan, a simultaneous integrated volume-adapted boost was created to the shrunken primary tumor with dose increases in 5 0.4-Gy steps from 66 Gy to 82 Gy in 2 scenarios: plan A, lung isotoxicity; plan B, normal tissue tolerance. Cumulative dose was assessed by deformably mapping and accumulating biologically equivalent dose normalized to 2 Gy-fractions (EQD2). Results: The 82-Gy level was achieved in 1 in 10 patients in scenario A, resulting in a 13.4-Gy EQD2 increase and a 22.1% increase in tumor control probability (TCP) compared to the 66-Gy plan. In scenario B, 2 patients reached the 82-Gy level with a 13.9 Gy EQD2 and 23.4% TCP increase. Conclusions: The tested image-guided adaptive radiation therapy strategy enabled relevant increases in EQD2 and TCP. Normal tissue was often dose limiting, indicating a need to modify the present study design before clinical implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of the Effect of Air Pollution Controls on Trends in Shortwave Radiation over the United States from 1995 through 2010 from Multiple Observation Networks

Long term datasets of total (all-sky) and clear-sky downwelling shortwave (SW) radiation, cloud cover fraction (cloudiness) and aerosol optical depth (AOD) are analyzed together with aerosol concentration from several networks (e.g. SURFRAD, CASTNET, IMPROVE and ARM) in the United States (US). Seven states with varying climatology are selected to better understand the effect of aerosols and clouds on SW radiation. This analysis aims to test the hypothesis that the reductions in anthropogenic aerosol burden resulting from substantial reductions in emissions of sulfur dioxide and nitrogen oxides over the past 15 years across the US has caused an increase in surface SW radiation. We show that the total and clear-sky downwelling SW radiation from seven sites have increasing trends except Penn State which shows no tendency in clear-sky SW radiation. After investigating several confounding factors, the causes can be due to the geography of the site, aerosol distribution, heavy air traffic and increasing cloudiness. Moreover, we assess the relationship between total column AOD with surface aerosol concentration to test our hypothesis. In our findings, the trends of clear-sky SW radiation, AOD, and aerosol concentration from the sites in eastern US agree well with our hypothesis. However, the sites in western US demonstrate increasing AOD associated with mostly increasing trends in surface aerosol concentration. At these sites, the changes in aerosol burden and/or direct aerosol effects alone cannot explain the observed changes in SW radiation, but other factors need to be considered such as cloudiness, aerosol vertical profiles and elevated plumes.

1995-2010↗

NASA/GSFC reliability evaluation of high temperature fiber optic cables

A high temperature (200 C rating) fiber-optic cable of fluorocarbon, silica-based glass, and polyimide coating, 100-micron core was evaluated for Goddard Space Flight Center applications. Testing was performed to evaluate attenuation characteristics of the cables during environmental stresses and exposure to Co-60 gamma radiation. The cables passed environmental tests, but after irradiation failed the established delta limit of 3 dB at 10 krads for a wavelength of 850 nm and 100 krads for a wavelength of 1300 nm.

Sharma, A. K.↗

Dual wavelength laser damage testing for high energy lasers.

As high energy laser systems evolve towards higher energies, fundamental material properties such as the laser-induced damage threshold (LIDT) of the optics limit the overall system performance. The Z-Backlighter Laser Facility at Sandia National Laboratories uses a pair of such kiljoule-class Nd:Phosphate Glass lasers for x-ray radiography of high energy density physics events on the Z-Accelerator. These two systems, the Z-Beamlet system operating at 527nm/ 1ns and the Z-Petawatt system operating at 1054nm/ 0.5ps, can be combined for some experimental applications. In these scenarios, dichroic beam combining optics and subsequent dual wavelength high reflectors will see a high fluence from combined simultaneous laser exposure and may even see lingering effects when used for pump-probe configurations. Only recently have researchers begun to explore such concerns, looking at individual and simultaneous exposures of optics to 1064 and third harmonic 355nm light from Nd:YAG [1]. However, to our knowledge, measurements of simultaneous and delayed dual wavelength damage thresholds on such optics have not been performed for exposure to 1054nm and its second harmonic light, especially when the pulses are of disparate pulse duration. The Z-Backlighter Facility has an instrumented damage tester setup to examine the issues of laser-induced damage thresholds in a variety of such situations [2] . Using this damage tester, we have measured the LIDT of dual wavelength high reflectors at 1054nm/0.5ps and 532nm/7ns, separately and spatially combined, both co-temporal and delayed, with single and multiple exposures. We found that the LIDT of the sample at 1054nm/0.5ps can be significantly lowered, from 1.32J/cm{sup 2} damage fluence with 1054/0.5ps only to 1.05 J/cm{sup 2} with the simultaneous presence of 532nm/7ns laser light at a fluence of 8.1 J/cm{sup 2}. This reduction of LIDT of the sample at 1054nm/0.5ps continues as the fluence of 532nm/7ns laser light simultaneously present increases. The reduction of LIDT does not occur when the 2 pulses are temporally separated. This paper will also present dual wavelength LIDT results of commercial dichroic beam-combining optics simultaneously exposed with laser light at 1054nm/2.5ns and 532nm/7ns.

43 PARTICLE ACCELERATORS↗

Characterization of the Pulsed Radiation Environment in FREC-II at the ACRR

Ongoing tests at the Annular Core Research Reactor (ACRR) at Sandia National Laboratories aim to measure temperature and strain in materials exposed to a transient neutron-photon environment. Radiation transport and finite element analysis codes are used to predict the thermal-structural response of test articles exposed in the reactor. Strain and temperature sensors fielded on test articles provide validation data for finite element models, while active and passive radiation dosimetry provides data for MCNP models. The ACRR is able to provide pulse energies of 40 - 300 MJ per pulse with pulse times of 7 - 100 milliseconds. The pulse power is higher than many of the other research reactors due to its unique high heat capacity UO{sub 2}-BeO fuel in the central reactor. Additionally, the Fuel Ringed External Cavity (FREC-II) contains U-ZrH fuel. Future tests at the ACRR plan to field test assemblies in the Fuel Ringed External Cavity (FREC-II) and expose the test articles to the transient anisotropic radiation field experienced in the cavity. The FREC-II is coupled with the ACRR core and is used to test larger specimens, and the radiation environment can be shaped/modified to the needs of the experiment. The FREC-II was designed to provide an irradiation cavity with a strong flux gradient favoring the central cavity side. Neutron fluence also varies by height in the cavity, with a peak level slightly below the fuel rod vertical centerline. Tests were conducted in 2014 to measure the thermal-structural response of test articles exposed in the central cavity. Those tests in the central cavity fielded Nickel activation foils to record the neutron fluence at various locations around the test assembly. Foil data was later used to highlight uncertainties between thermo-structural response models and the measured temperature and strain. Studies performed in 2015 exposed large arrays of activation foils and thermo-luminescent dosimeters (TLD) in the FREC-II cavity in order to map out the neutron and photon spectrum at many locations. This type of passive measurement was shown to be too simple for performing thermo-structural simulations of a test article in response to multiple pulsed-reactor exposures. The Depleted Uranium Strain and Temperature - Enhanced Response (DUSTER-II) experiments will expose test assemblies to reactor pulses in the FREC-II cavity. To prepare for these experiments, the MCNP model will be compared with June 2016 experimental results from the pulses with the FREC-II coupled with the ACRR. These comparisons will provide an accurate model to be implemented in further studies. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Advanced Thermal Radiator for Global Lunar Heat Rejection

An advanced thermal radiator innovation to provide global heat rejection for Lunar exploration is described in this paper. Infrared background radiation from Lunar terrain can seriously compromise the performance of conventional thermal radiators, especially at lower latitudes. The Apollo missions boiled consumable H2O for heat rejection which would be unsustainable for long duration Lunar exploration where temperatures may exceed 250°F at the equator. The proposed innovation would provide indefinite, sustainable heat rejection for orbiting assets, rovers, landers and habitats over the entire surface of the Moon. The advanced radiator concept introduces a semi-transparent cover-glass to transmit and reflect both incident infrared radiation and solar irradiation to facilitate improved heat rejection. With sponsorship from MSFC Center Innovation Funding (CIF), two advanced radiator concepts were fabricated and evaluated inside the High Intensity Solar Environment Test (HISET) facility thermal vacuum chamber at MSFC. Using custom designed and fabricated test stands in the HISET chamber, the tests simulated both the Lunar terrestrial (inside a crater under full sun) and orbital thermal environments. A conventional radiator was also fabricated and tested under identical conditions for comparison. Test results indicate improved radiator performance (relative to conventional) in the Lunar orbital environment but the advanced radiators did not perform as well as expected in the surface environment. Correlation to thermal math models is presented and future research may consider alternate materials or designs to improve the terrestrial performance.

Thermal Control System↗

Gravitational-radiation losses from the pulsar-white-dwarf binary PSR J1141-6545

Pulsars in close binary systems with white dwarfs or other neutron stars make ideal laboratories for testing the predictions of gravitational radiation and self-gravitational effects. We report new timing measurements of the pulsar-white-dwarf binary PSR J1141-6545. The orbit is found to be decaying at a rate of 1.04{+-}0.06 times the general relativistic prediction and the Shapiro delay is consistent with the orbital inclination angle derived from scintillation measurements. The system provides a unique testbed for tensor-scalar theories of gravity. Our measurements place stringent constraints in the theory space, with a limit of {alpha}{sub 0}{sup 2}<2.1x10{sup -5} for weakly nonlinear coupling and an asymptotic limit of {alpha}{sub 0}{sup 2}<3.4x10{sup -6} for strongly nonlinear coupling (where {alpha}{sub 0} is the linear coupling strength of matter to an underlying scalar field), which is nearly 3 times smaller than the Cassini bound ({alpha}{sub 0}{sup 2}{approx_equal}10{sup -5})

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Studies of the acoustic transmission characteristics of coaxial nozzles with inverted velocity profiles, volume 1

The efficiency of internal noise radiation through coannular exhaust nozzle with an inverted velocity profile was studied. A preliminary investigation was first undertaken to: (1) define the test parameters which influence the internal noise radiation; (2) develop a test methodology which could realistically be used to examine the effects of the test parameters; (3) and to validate this methodology. The result was the choice of an acoustic impulse as the internal noise source in the in the jet nozzles. Noise transmission characteristics of a nozzle system were then investigated. In particular, the effects of fan nozzle convergence angle, core extention length to annulus height ratio, and flow Mach number and temperatures were studied. The results are presented as normalized directivity plots.

Dean, P. D.↗

An infrared heterodyne radiometer for high-resolution measurements of solar radiation and atmospheric transmission

A tunable, Dicke-switched, infrared heterodyne radiometer (IHR) has been designed, fabricated, tested, and used to observe solar radiation and determine the atmospheric transmissivity in the 9-11-micron spectral band. The IHR provides a spectral resolution of 0.0067 reciprocal cm, a minimum detectable power level of 2.9 times ten to the minus twenty-third power W/Hz, and a temperature resolution of less than 1 K for a source temperature of 1000 K, an IF predetection bandwidth of 100 MHz, and an integration time of 30 s. Detailed design equations and measured IHR performance are presented. The IHR was used to make solar and atmospheric transmission measurements, and a vertical-path atmospheric attenuation of 2.3 dB has been established under favorable weather conditions. The attenuation of solar radiation due to cloud cover and haze has also been investigated.

Peyton, B. J.↗

Tritium transfer in pigs - A model test

In the frame of IAEA EMRAS (Environmental Modelling for Radiation Safety) programme, there was developed a scenario for models ' testing starting with unpublished data for a sow fed with OBT for 84 days. The scenario includes model predictions for the dynamics of tritium in urine and faeces and HTO and OBT in organs at sacrifice. There have been done two inter-comparison exercises and most of the models succeeded to give predictions better than a factor 3 to 5, excepting faeces. There has been done an analysis of models' structure, performance and limits in order to be able to build a model of moderate complexity with a reliable predictive power, able to be applied for human dosimetry, also, when OBT data are missing. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

A Study on the Use of XCT and FEA to Predict the Elastic Behavior of Additively Manufactured Parts of Cylindrical Geometry

Defining general criteria for the acceptability of defects within industrial components is often complicated, since the specific load conditions and the criticality of the given application should be considered individually. In order to minimize the risk of failure, high safety factors are commonly adopted during quality control. However this practice is likely to cause the rejection of components whose defects would be instead acceptable if a more sound knowledge of the component behaviour were achieved. Parts produced by additive manufacturing (AM) may suffer from various defects, including micro- or macro-holes, delamination and microstructural discontinuities. Such processes, which are specially suitable for one-off components, require robust and reliable inspection before a part is accepted or rejected, since the refusal of even a single part at the end of the production process represents a significant loss. For this reason, it would be very useful to simulate in a reliable way whether a certain defect is truly detrimental to the proper working of the part during operation or whether the component can still be used, despite the presence of a defect. To this purpose, the paper highlights the benefits of a synergistic interaction between Industrial X-ray computed tomography (XCT) and finite element analysis (FEA). Internal defects of additively manufactured parts can be identified in a non-destructive way by means of XCT. Then FEA can be performed on the XCT-based virtual model of the real component, rather than on the ideal CAD geometry. A proof of concept of this approach is proposed here for a reference construct produced in an Aluminium alloy by AM. Numerical results of the proposed combined XCT–FEA procedure are contrasted with experimental data from tensile tests. The findings sustain the reliability of the method and allow to assess its full provisional accuracy for parts of cylindrical geometry designed to operate in the elastic field. The paper moves a step beyond the present application limits of tomography as it is currently employed for AM parts and it evidences instead the possibility of extending the usage of tomography to acceptance testing and prediction of operative behaviour.

42 ENGINEERING↗

Effect of Heat Treatment on Microstructure and Mechanical Properties of Laser Additively Manufactured AISI H13 Tool Steel

The effect of heat treatment on microstructure and mechanical properties (microhardness, wear resistance and impact toughness) of laser additively manufactured AISI H13 tool steel was systemically investigated. To understand the variation of microstructure and mechanical properties under different heat treatments, the as-deposited samples were treated at 350, 450, 550, 600 and 650 °C/2 h, respectively. Microstructure and phase transformation were investigated through optical microscopy, scanning electron microscope and transmission electron microscope. The mechanical properties were characterized by nanoindentation tests, Charpy tests and high-temperature wear tests. The microstructure of as-deposited samples consisted of martensite, ultrafine carbides and retained austenite. After the tempering treatment, the martensite was converted into tempered martensite and some fine alloy carbides which precipitated in the matrix. When treated at 550 °C, the greatest hardness and nanohardness were 600 HV{sub 0.3} and 6119.4 MPa due to many needle-like carbides precipitation. The value of hardness increased firstly and then decreased when increasing the temperature. When tempered temperatures exceeded 550 °C, the carbides became coarse, and martensitic matrix recrystallized at the temperature of 650 °C. The least impact energy was 6.0 J at a temperature of 550 °C. Samples tempered at 550 °C had larger wear volume loss than that of others. Wear resistances of all samples under atmospheric condition at 400 °C showed an oxidation mechanism.

36 MATERIALS SCIENCE↗

Diagnosing delayed ettringite formation in concrete structures

There has been a number of cases involving deteriorated concrete structures in North America where there has been considerable controversy surrounding the respective contributions of alkali-silica reaction (ASR) and delayed ettringite formation (DEF) to the observed damage. The problem arises because the macroscopic symptoms of distress are not unequivocal and microscopical examinations of field samples often reveal evidence of both processes making it difficult to separate the individual contributions. This paper presents the results of an investigation of a number of concrete columns carrying a raised expressway in North America; prior studies had implicated both DEF and ASR as possible causes of deterioration. Although the columns were not deliberately heat-cured, it is estimated that the peak internal temperature would have exceeded 70 deg. C and perhaps even 80 deg. C, in some cases. The forensic investigation included scanning electron microscopy with energy-dispersive X-ray analysis and expansion testing of cores extracted from the structure. Small-diameter cores stored in limewater expanded significantly (0.3 to 1.3%) and on the basis of supplementary tests on laboratory-produced concrete specimens it was concluded that expansion under such conditions is caused by DEF as the conditions of the test will not sustain ASR. In at least one column, DEF was diagnosed as the sole contributory cause of damage with no evidence of any contribution from ASR or any other deterioration process. In other cases, both ASR and DEF were observed to have contributed to the apparent damage. Of the columns examined, only concrete containing fly ash appeared to be undamaged. The results of this study confirm that, under certain conditions, the process of DEF (acting in isolation of other processes) can result in significant deterioration of cast-in-place reinforced concrete structures.

36 MATERIALS SCIENCE↗

Distant Metastases in Head-and-Neck Squamous Cell Carcinoma Treated With Intensity-Modulated Radiotherapy

Purpose: To determine the pattern and risk factors for distant metastases in head-and-neck squamous cell carcinoma (HNSCC) after curative treatment with intensity-modulated radiotherapy (IMRT). Methods and Materials: This was a retrospective study of 284 HNSCC patients treated in a single institution with IMRT. Sites included were oropharynx (125), oral cavity (70), larynx (55), hypopharynx (17), and unknown primary (17). American Joint Committee on Cancer stage distribution includes I (3), II (19), III (42), and IV (203). There were 224 males and 60 females with a median age of 57. One hundred eighty-six patients were treated with definitive IMRT and 98 postoperative IMRT. One hundred forty-nine patients also received concurrent cisplatin-based chemotherapy. Results: The median follow-up for all patients was 22.8 months (range, 0.07-77.3 months) and 29.5 months (4.23-77.3 months) for living patients. The 3-year local recurrence-free survival, regional recurrence-free survival, locoregional recurrence-free survival, distant metastasis-free survival, and overall survival were 94.6%, 96.4%, 92.5%, 84.1%, and 68.95%, respectively. There were 45 patients with distant metastasis. In multivariate analysis, distant metastasis was strongly associated with N stage (p = 0.046), T stage (p < 0.0001), and pretreatment maximum standardized uptake value of the lymph node (p = 0.006), but not associated with age, gender, disease sites, pretreatment standardized uptake value of the primary tumor, or locoregional control. The freedom from distant metastasis at 3 years was 98.1% for no factors, 88.6% for one factor, 68.3% for two factors, and 41.7% for three factors (p < 0.0001 by log-rank test). Conclusion: With advanced radiation techniques and concurrent chemotherapy, the failure pattern has changed with more patients failing distantly. The majority of patients with distant metastases had no local or regional failures, indicating that these patients might have microscopic distant disease before treatment. The clinical factors identified here should be incorporated in future clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Second-order accurate interface- and discontinuity-aware diffusion solvers in two and three dimensions

A numerical scheme is developed for two- and three-dimensional time-dependent diffusion equations in numerical simulations involving mixed cells. The focus of the development is on the formulations for both transient and steady states, the property for large time steps, second-order accuracy in both space and time, the correct treatment of the discontinuity in material properties, and the handling of mixed cells. For a mixed cell, interfaces between materials are reconstructed within the cell so that each of resulting sub-cells contains only one material and the material properties of each sub-cell are known. Diffusion equations are solved on the resulting polyhedral mesh even if the original mesh is structured. The discontinuity of material properties between different materials is correctly treated based on governing physics principles. The treatment is exact for arbitrarily strong discontinuity. The formulae for effective diffusion coefficients across interfaces between materials are derived for general polyhedral meshes. The scheme is general in two and three dimensions. Since the scheme to be developed in this paper is intended for multi-physics code with adaptive mesh refinement (AMR), we present the scheme on mesh generated from AMR. The correctness and features of the scheme are demonstrated for transient problems and steady states in one-, two-, and three-dimensional simulations for heat conduction and radiation heat transfer. The test problems involve dramatically different materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of radiation damage and precipitate distribution on micro-pillar compression testing of irradiated CuCrZr

The results of small-scale mechanical tests are convoluted by the so-called size effect, whereby materials appear stronger when the scale of the test is reduced to the order of microns or less. The dimensional range over which this occurs has been shown to be linked to a change in sample microstructure, such as the addition of defects induced by irradiation. To investigate this response, a CuCrZr alloy was subjected to proton irradiation and mechanically tested using micro compression of pillars with a range in size. It was found that irradiation defects dominate over the extrinsic size effect and the sensitivity to differences in precipitate microstructure was also somewhat reduced, suggesting that size-independent results could be obtained from much smaller test volumes in irradiated material compared to their non-irradiated counterparts. Lastly, comparison was made between the increase in yield strength predicted by models and the experimentally measured values to establish the key parameters driving the strengthening behaviour.

36 MATERIALS SCIENCE↗