Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Robust methods for automatic image-to-world registration in cone-beam CT interventional guidance

Purpose: Real-time surgical navigation relies on accurate image-to-world registration to align the coordinate systems of the image and patient. Conventional manual registration can present a workflow bottleneck and is prone to manual error and intraoperator variability. This work reports alternative means of automatic image-to-world registration, each method involving an automatic registration marker (ARM) used in conjunction with C-arm cone-beam CT (CBCT). The first involves a Known-Model registration method in which the ARM is a predefined tool, and the second is a Free-Form method in which the ARM is freely configurable. Methods: Studies were performed using a prototype C-arm for CBCT and a surgical tracking system. A simple ARM was designed with markers comprising a tungsten sphere within infrared reflectors to permit detection of markers in both x-ray projections and by an infrared tracker. The Known-Model method exercised a predefined specification of the ARM in combination with 3D-2D registration to estimate the transformation that yields the optimal match between forward projection of the ARM and the measured projection images. The Free-Form method localizes markers individually in projection data by a robust Hough transform approach extended from previous work, backprojected to 3D image coordinates based on C-arm geometric calibration. Image-domain point sets were transformed to world coordinates by rigid-body point-based registration. The robustness and registration accuracy of each method was tested in comparison to manual registration across a range of body sites (head, thorax, and abdomen) of interest in CBCT-guided surgery, including cases with interventional tools in the radiographic scene. Results: The automatic methods exhibited similar target registration error (TRE) and were comparable or superior to manual registration for placement of the ARM within {approx}200 mm of C-arm isocenter. Marker localization in projection data was robust across all anatomical sites, including challenging scenarios involving the presence of interventional tools. The reprojection error of marker localization was independent of the distance of the ARM from isocenter, and the overall TRE was dominated by the configuration of individual fiducials and distance from the target as predicted by theory. The median TRE increased with greater ARM-to-isocenter distance (e.g., for the Free-Form method, TRE increasing from 0.78 mm to 2.04 mm at distances of {approx}75 mm and 370 mm, respectively). The median TRE within {approx}200 mm distance was consistently lower than that of the manual method (TRE = 0.82 mm). Registration performance was independent of anatomical site (head, thorax, and abdomen). The Free-Form method demonstrated a statistically significant improvement (p= 0.0044) in reproducibility compared to manual registration (0.22 mm versus 0.30 mm, respectively). Conclusions: Automatic image-to-world registration methods demonstrate the potential for improved accuracy, reproducibility, and workflow in CBCT-guided procedures. A Free-Form method was shown to exhibit robustness against anatomical site, with comparable or improved TRE compared to manual registration. It was also comparable or superior in performance to a Known-Model method in which the ARM configuration is specified as a predefined tool, thereby allowing configuration of fiducials on the fly or attachment to the patient.

60 APPLIED LIFE SCIENCES↗

Electronic structure and morphology of epitaxial Bi{sub 2}Te{sub 2}Se topological insulator films

Epitaxial films of the ternary topological insulator Bi{sub 2}Te{sub 2}Se were grown on Si(111) substrates and investigated for their surface electronic properties and morphology. We employ a Se-capping procedure allowing for the preparation of clean films in the surface-analysis experimental setups. Using angle-resolved photoelectron spectroscopy, we determine the dispersion of the topological surface state. With time after surface preparation, the spectroscopic features in the surface electronic structure exhibit significant temperature-dependent shifts to higher binding energies. Scanning tunneling microscopy images show terraces with typical step edge separations of 50 nm–150 nm. X-ray photoelectron spectroscopy indicates an increased Se concentration at the surface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accelerated nanoscale magnetic resonance imaging through phase multiplexing

We report a method for accelerated nanoscale nuclear magnetic resonance imaging by detecting several signals in parallel. Our technique relies on phase multiplexing, where the signals from different nuclear spin ensembles are encoded in the phase of an ultrasensitive magnetic detector. We demonstrate this technique by simultaneously acquiring statistically polarized spin signals from two different nuclear species ({sup 1}H, {sup 19}F) and from up to six spatial locations in a nanowire test sample using a magnetic resonance force microscope. We obtain one-dimensional imaging resolution better than 5 nm, and subnanometer positional accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An algorithm to unveil the inner structure of objects concealed by beam divergence in radiographic image acquisition systems

Two main parameters rule the performance of an Image Acquisition System, namely, spatial resolution and contrast. For radiographic systems using cone beam arrangements, the farther the source, the better the resolution, but the contrast would diminish due to the lower statistics. A closer source would yield a higher contrast but it would no longer reproduce the attenuation map of the object, as the incoming beam flux would be reduced by unequal large divergences and attenuation factors. This work proposes a procedure to correct these effects when the object is comprised of a hull - or encased in it - possessing a shape capable to be described in analytical geometry terms. Such a description allows the construction of a matrix containing the attenuation factors undergone by the beam from the source until its final destination at each coordinate on the 2D detector. Each matrix element incorporates the attenuation suffered by the beam after its travel through the hull wall, as well as its reduction due to the square of distance to the source and the angle it hits the detector surface. When the pixel intensities of the original image are corrected by these factors, the image contrast, reduced by the overall attenuation in the exposure phase, are recovered, allowing one to see details otherwise concealed due to the low contrast. In order to verify the soundness of this approach, synthetic images of objects of different shapes, such as plates and tubes, incorporating defects and statistical fluctuation, have been generated, recorded for further comparison and afterwards processed to improve their contrast. The developed algorithm which, generates processes and plots the images has been written in Fortran 90 language. As the resulting final images exhibit the expected improvements, it therefore seemed worthwhile to carry out further tests with actual experimental radiographies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-T-463: Light-Field Based Dynalog Verification

Purpose: To independently verify leaf positions in so-called dynalog files for a Varian iX linac with a Millennium 120 MLC. This verification provides a measure of confidence that the files can be used directly as part of a more extensive intensity modulated radiation therapy / volumetric modulated arc therapy QA program. Methods: Initial testing used white paper placed at the collimator plane and a standard hand-held digital camera to image the light and shadow of a static MLC field through the paper. Known markings on the paper allow for image calibration. Noise reduction was attempted with removal of ‘inherent noise’ from an open-field light image through the paper, but the method was found to be inconsequential. This is likely because the environment could not be controlled to the precision required for the sort of reproducible characterization of the quantum noise needed in order to meaningfully characterize and account for it. A multi-scale iterative edge detection algorithm was used for localizing the leaf ends. These were compared with the planned locations from the treatment console. Results: With a very basic setup, the image of the central bank A leaves 15–45, which are arguably the most important for beam modulation, differed from the planned location by [0.38±0.28] mm. Similarly, for bank B leaves 15–45 had a difference of [0.42±0.28] mm Conclusion: It should be possible to determine leaf position accurately with not much more than a modern hand-held camera and some software. This means we can have a periodic and independent verification of the dynalog file information. This is indicated by the precision already achieved using a basic setup and analysis methodology. Currently, work is being done to reduce imaging and setup errors, which will bring the leaf position error down further, and allow meaningful analysis over the full range of leaves.

60 APPLIED LIFE SCIENCES↗

Kinetic energy dependence of carrier diffusion in a GaAs epilayer studied by wavelength selective PL imaging

Photoluminescence (PL) imaging has been shown to be an efficient technique for investigating carrier diffusion in semiconductors. In the past, the measurement was typically carried out by measuring at one wavelength (e.g., at the band gap) or simply the whole emission band. At room temperature in a semiconductor like GaAs, the band-to-band PL emission may occur in a spectral range over 200 meV, vastly exceeding the average thermal energy of about 26 meV. To investigate the potential dependence of the carrier diffusion on the carrier kinetic energy, we performed wavelength selective PL imaging on a GaAs double hetero-structure in a spectral range from about 70 meV above to 50 meV below the bandgap, extracting the carrier diffusion lengths at different PL wavelengths by fitting the imaging data to a theoretical model. The results clearly show that the locally generated carriers of different kinetic energies mostly diffuse together, maintaining the same thermal distribution throughout the diffusion process. Potential effects related to carrier density, self-absorption, lateral wave-guiding, and local heating are also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of pumping level on the uniformity of the power and spectrum distributions over the emitting aperture of cw laser diode bars

Thermal parameters of cw laser diode bars (LDBs) have been studied experimentally and using 3D simulation in order to identify factors limiting their output power and operational life. Using a thermal camera, we have obtained thermal field images of 47-cluster LDBs with an aperture fill factor of 50 %, packaged in a heat spreader of the C – S mount type. Distributions of the output power and emission spectrum of the emitting clusters have been measured by a probing method. The simulation results and experimental data have been analysed, compared and discussed. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Submicron Spatial Modulation of an Interatomic Interaction in a Bose-Einstein Condensate

We demonstrate submicron spatial control of interatomic interactions in a Bose-Einstein condensate of ytterbium (Yb). A pulsed optical standing wave, tuned near an optical Feshbach resonance, varies the s-wave scattering length continuously across the standing wave pattern. The modulated mean-field energy with a spatial period every 278 nm is monitored by a diffraction pattern in a time-of-flight image. We observe a wide scattering length control of up to 250 nm. The demonstrated spatial modulation of the scattering length proves that high resolution control of atomic interactions is possible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Semiconductor quantum dots: Technological progress and future challenges

In quantum-confined semiconductor nanostructures, electrons exhibit distinctive behavior compared with that in bulk solids. This enables the design of materials with tunable chemical, physical, electrical, and optical properties. Zero-dimensional semiconductor quantum dots (QDs) offer strong light absorption and bright narrowband emission across the visible and infrared wavelengths and have been engineered to exhibit optical gain and lasing. These properties are of interest for imaging, solar energy harvesting, displays, and communications. Here, we offer an overview of advances in the synthesis and understanding of QD nanomaterials, with a focus on colloidal QDs, and discuss their prospects in technologies such as displays and lighting, lasers, sensing, electronics, solar energy conversion, photocatalysis, and quantum information.

García de Arquer, F. Pelayo↗

VERTICAL RELAXATION OF A MOONLET PROPELLER IN SATURN'S A RING

Two images, taken by the Cassini spacecraft near Saturn's equinox in 2009 August, show the Earhart propeller casting a 350 km long shadow, offering the opportunity to watch how the ring height, excited by the propeller moonlet, relaxes to an equilibrium state. From the shape of the shadow cast and a model of the azimuthal propeller height relaxation, we determine the exponential cooling constant of this process to be {lambda} = 0.07 {+-} 0.02 km{sup -1}, and thereby determine the collision frequency of the ring particles in the vertically excited region of the propeller to be {omega}{sub c}/{Omega} = 0.9 {+-} 0.2.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An algorithm for efficient metal artifact reductions in permanent seed implants

Purpose: In permanent seed implants, 60 to more than 100 small metal capsules are inserted in the prostate, creating artifacts in x-ray computed tomography (CT) imaging. The goal of this work is to develop an automatic method for metal artifact reduction (MAR) from small objects such as brachytherapy seeds for clinical applications. Methods: The approach for MAR is based on the interpolation of missing projections by directly using raw helical CT data (sinogram). First, an initial image is reconstructed from the raw CT data. Then, the metal objects segmented from the reconstructed image are reprojected back into the sinogram space to produce a metal-only sinogram. The Steger method is used to determine precisely the position and edges of the seed traces in the raw CT data. By combining the use of Steger detection and reprojections, the missing projections are detected and replaced by interpolation of non-missing neighboring projections. Results: In both phantom experiments and patient studies, the missing projections have been detected successfully and the artifacts caused by metallic objects have been substantially reduced. The performance of the algorithm has been quantified by comparing the uniformity between the uncorrected and the corrected phantom images. The results of the artifact reduction algorithm are indistinguishable from the true background value. Conclusions: An efficient algorithm for MAR in seed brachytherapy was developed. The test results obtained using raw helical CT data for both phantom and clinical cases have demonstrated that the proposed MAR method is capable of accurately detecting and correcting artifacts caused by a large number of very small metal objects (seeds) in sinogram space. This should enable a more accurate use of advanced brachytherapy dose calculations, such as Monte Carlo simulations.

60 APPLIED LIFE SCIENCES↗

Development of scanning electron and x-ray microscope

We have developed a new type of microscope possessing a unique feature of observing both scanning electron and X-ray images under one unit. Unlike former X-ray microscopes using SEM [1, 2], this scanning electron and X-ray (SELX) microscope has a sample in vacuum, thus it enables one to observe a surface structure of a sample by SEM mode, to search the region of interest, and to observe an X-ray image which transmits the region. For the X-ray observation, we have been focusing on the soft X-ray region from 280 eV to 3 keV to observe some bio samples and soft materials. The resolutions of SEM and X-ray modes are 50 nm and 100 nm, respectively, at the electron energy of 7 keV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-resolved photoelectron imaging using a femtosecond UV laser and a VUV free-electron laser

A time-resolved photoelectron imaging using a femtosecond ultraviolet (UV) laser and a vacuum UV free-electron laser is presented. Ultrafast internal conversion and intersystem crossing in pyrazine in a supersonic molecular beam were clearly observed in the time profiles of photoioinzation intensity and time-dependent photoelectron images.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear negative refraction by difference frequency generation

Negative refraction has attracted much interest for its promising capability in imaging applications. Such an effect can be implemented by negative index meta-materials, however, which are usually accompanied by high loss and demanding fabrication processes. Recently, alternative nonlinear approaches like phase conjugation and four wave mixing have shown advantages of low-loss and easy-to-implement, but associated problems like narrow accepting angles can still halt their practical applications. Here, we demonstrate theoretically and experimentally a scheme to realize negative refraction by nonlinear difference frequency generation with wide tunability, where a thin Beta barium borate slice serves as a negative refraction layer bending the input signal beam to the idler beam at a negative angle. Furthermore, we realize optical focusing effect using such nonlinear negative refraction, which may enable many potential applications in imaging science.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Poisson equation for weak gravitational lensing

Using the Newman and Penrose [E. T. Newman and R. Penrose, J. Math. Phys. (N.Y.) 3, 566 (1962).] spin-coefficient formalism, we examine the full Bianchi identities of general relativity in the context of gravitational lensing, where the matter and space-time curvature are projected into a lens plane perpendicular to the line of sight. From one component of the Bianchi identity, we provide a rigorous, new derivation of a Poisson equation for the projected matter density where the source term involves second derivatives of the observed weak gravitational lensing shear. We also show that the other components of the Bianchi identity reveal no new results. Numerical integration of the Poisson equation in test cases shows an accurate mass map can be constructed from the combination of a ground-based, wide-field image and a Hubble Space Telescope image of the same system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Autonomous Sub-Pixel Satellite Track Endpoint Determination for Space Based Images

An algorithm for determining satellite track endpoints with sub-pixel resolution in spaced-based images is presented. The algorithm allows for significant curvature in the imaged track due to rotation of the spacecraft capturing the image. The motivation behind the subpixel endpoint determination is first presented, followed by a description of the methodology used. Results from running the algorithm on real ground-based and simulated spaced-based images are shown to highlight its effectiveness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparing implementations of penalized weighted least-squares sinogram restoration

Purpose: A CT scanner measures the energy that is deposited in each channel of a detector array by x rays that have been partially absorbed on their way through the object. The measurement process is complex and quantitative measurements are always and inevitably associated with errors, so CT data must be preprocessed prior to reconstruction. In recent years, the authors have formulated CT sinogram preprocessing as a statistical restoration problem in which the goal is to obtain the best estimate of the line integrals needed for reconstruction from the set of noisy, degraded measurements. The authors have explored both penalized Poisson likelihood (PL) and penalized weighted least-squares (PWLS) objective functions. At low doses, the authors found that the PL approach outperforms PWLS in terms of resolution-noise tradeoffs, but at standard doses they perform similarly. The PWLS objective function, being quadratic, is more amenable to computational acceleration than the PL objective. In this work, the authors develop and compare two different methods for implementing PWLS sinogram restoration with the hope of improving computational performance relative to PL in the standard-dose regime. Sinogram restoration is still significant in the standard-dose regime since it can still outperform standard approaches and it allows for correction of effects that are not usually modeled in standard CT preprocessing. Methods: The authors have explored and compared two implementation strategies for PWLS sinogram restoration: (1) A direct matrix-inversion strategy based on the closed-form solution to the PWLS optimization problem and (2) an iterative approach based on the conjugate-gradient algorithm. Obtaining optimal performance from each strategy required modifying the naive off-the-shelf implementations of the algorithms to exploit the particular symmetry and sparseness of the sinogram-restoration problem. For the closed-form approach, the authors subdivided the large matrix inversion into smaller coupled problems and exploited sparseness to minimize matrix operations. For the conjugate-gradient approach, the authors exploited sparseness and preconditioned the problem to speed up convergence. Results: All methods produced qualitatively and quantitatively similar images as measured by resolution-variance tradeoffs and difference images. Despite the acceleration strategies, the direct matrix-inversion approach was found to be uncompetitive with iterative approaches, with a computational burden higher by an order of magnitude or more. The iterative conjugate-gradient approach, however, does appear promising, with computation times half that of the authors' previous penalized-likelihood implementation. Conclusions: Iterative conjugate-gradient based PWLS sinogram restoration with careful matrix optimizations has computational advantages over direct matrix PWLS inversion and over penalized-likelihood sinogram restoration and can be considered a good alternative in standard-dose regimes.

60 APPLIED LIFE SCIENCES↗

Correlating exciton localization with compositional fluctuations in InGaN/GaN quantum wells grown on GaN planar surfaces and facets of GaN triangular prisms

We have used spatially and temporally resolved cathodoluminescence (CL) to study the carrier recombination dynamics of InGaN quantum wells (QWs) grown on (0001)-oriented planar GaN and (1101)-oriented facets of GaN triangular prisms prepared by lateral epitaxial overgrowth in a metal-organic chemical vapor deposition system. The effects of In migration during growth on the resulting QW thickness and composition were examined. We employed a variable temperature time-resolved CL imaging approach that enables a spatial correlation between regions of enhanced exciton localization, luminescence efficiency, and radiative lifetime with the aim of distinguishing between excitons localized in In-rich quantum dots and those in the surrounding Ga-rich QW regions.

36 MATERIALS SCIENCE↗