Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Multi-Analytical Investigation of Arsenical Transfer and Remediation on Nineteenth-Century Green Books

Books containing heavy metals, specifically nineteenth-century green arsenical books, have been identified at Northwestern University Libraries, raising health and safety concerns related to handling. Copper acetoarsenite pigments, such as emerald green, were detected on book covers, decorative page edges, labels, and other components using noninvasive analytical techniques including X-ray fluorescence (XRF), Raman spectroscopy, and Fourier-transform infrared (FTIR) spectroscopy. Further examination of selected volumes using synchrotron radiation (SR) techniques revealed pigment migration, degradation, and arsenic transfer to adjacent books. This paper expands on initial findings through two related experiments. The first explored the transfer of arsenic using mechanical friction; Staedtler Mars® white vinyl erasers rubbed on arsenical books generated crumbs which were analyzed via scanning electron microscopy–energy-dispersive X-ray spectroscopy (SEM-EDX). Results confirmed the transfer of arsenic, copper, and lead, with decorative page edges being particularly prone to shedding arsenic onto other materials. The second experiment tested remediation methods on a book contaminated by prolonged exposure to an arsenical neighbor. Surface cleaning using erasers and a vacuum removed flecks of pigment but did not eliminate non-chromophoric arsenic as confirmed by SR analyses, which highlights its presence either as a degradation product embedded within the paper or present in the paper as part of its production process. Findings demonstrate the acute toxicity risk posed by arsenical books and support the need for safe handling protocols. However, materials with only trace levels of arsenic embedded during production may pose a lower risk of transfer. Cross contamination beyond prolonged direct contact appears limited. These results highlight critical considerations for library preservation practices and future research on arsenic in historical materials.

arsenic↗

Automated remote sensing tools to counter illicit maritime activity: vessel detection, bathymetry and topography from WorldView imagery

Illicit maritime activity, such as piracy and smuggling, is a global issue that often occurs in areas where interdiction authorities are sparse, ground-based monitoring technologies like radar lack range and coverage, and dark vessels abound. Our objective was to assess vessel congregation patterns, identify likely beaching areas based on terrain maps, and use them to narrow the search for potential smuggling transfer and overland routes in a specific region along the Puntland coast of Somalia. To accomplish this goal, we developed automated protocols applied to WorldView satellite imagery for (1) vessel detection and size classification, (2) shallow-water bathymetric characterization, and (3) coastal topography mapping. Utilizing a single sensor for vessel detection and topographic and bathymetric extraction at high spatial resolution and at a high re-visit rate provides a simplification to near-shore characterization for monitoring purposes. The extracted topography and bathymetry are then presented as a single, comprehensive perspective of a coastal region. The vessel-detection algorithm identified all vessels larger than approximately 15 metres in length (35 of 35), but misidentified six artefacts (i.e. false positives), resulting in an overall accuracy of 85%. The combined vessel and terrain maps facilitated the identification of a potential beaching and overland transportation route location.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Ceci N’est Pas Une Bombe: Lessons from a Field Experiment Using Neutron and Gamma Measurements to Confirm the Absence of Nuclear Weapons

In March 2023, the UN Institute for Disarmament Research held a verification experiment that included a mockup onsite inspection at a former military facility in the municipality of Menzingen, Switzerland. The experiment included a visit to the site by an inspection team, accompanied by the host team. Among other activities, radiation measurements were used to confirm the non-nuclear nature of selected items stored onsite. In this paper, we discuss the neutron and gamma measurement systems used during the experiment and the inspection protocols followed to confirm the absence of nuclear weapons. Furthermore, results from the experiment and a laboratory reproduction are presented, before concluding with lessons learned for how absence-confirmation measurements can help support verification of future arms control agreements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 1: Particulate and gaseous emissions

This study investigated how heat demand and fuel loading affect the emissions from outdoor wood-fired hydronic heaters by testing two such appliances using an integrated-duty cycle test method. This test included transient operating conditions, such as cold and hot-starts and modulation between 15 and 100% of maximum rated output. Emission values indicate transient operating conditions produce higher emissions than steady state operation. Cold starts resulted in elevated particulate matter emission factors for both appliances; in one case the particulate matter emission factor for this period was >3500 mg/MJ, which represented emissions 20 times the average value. Additionally, when heat demand was cycled—elevated CO emission factors were measured, with values >5000 mg/MJ for both appliances and more than 3 times the appliance averages, respectively. It follows that the appliance average particulate matter emission factors and CO emission factors were not representative of the actual EF values during these transient periods. In contrast, methane emission factors were relatively stable throughout all tested combustion conditions; however, they were much higher than oil-fired appliances are therefore should not be ignored. These findings demonstrate that wood-fired hydronic heater emissions during transient operating conditions can be significantly greater than emissions during steady-state test conditions, such as those used in typical certification tests. Consequently, certification test values for particulate matter and CO emission factors may significantly underestimate the actual emissions of these appliances when operated in a home. Use of integrated duty-cycle test protocols that capture cold-starts and reloading are better for representing in-use operations of wood-fired hydronic heaters and provide more realistic emissions and delivered efficiency measurements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LAMP Diagnostics at the Point-of-Care: Emerging Trends and Perspectives for the Developer Community

Over the past decade, loop-mediated isothermal amplification (LAMP) technology has played an important role in molecular diagnostics. Amongst numerous nucleic acid amplification assays, LAMP stands out in terms of sample-to-answer time, sensitivity, specificity, cost, robustness, and accessibility, making it ideal for field-deployable diagnostics in resource-limited regions. In this review, we outline the front-end LAMP design practices for point-of-care (POC) applications, including sample handling and various signal readout methodologies. Next, we explore existing LAMP technologies that have been validated with clinical samples in the field. We summarize recent work that utilizes reverse transcription (RT) LAMP to rapidly detect SARS-CoV-2 as an alternative to standard PCR protocols. Finally, we describe challenges in translating LAMP from the benchtop to the field and opportunities for future LAMP assay development and performance reporting. Despite the popularity of LAMP in the academic research community and a recent surge in interest in LAMP due to the COVID-19 pandemic, there are numerous areas for improvement in the fundamental understanding of LAMP, which are needed to elevate the field of LAMP assay development and characterization.

60 APPLIED LIFE SCIENCES↗

Modification of Wool Fibers via Base/Cationic Detergent Pretreatment and Transglutaminase-mediated Reaction of Keratin

The surface modification of wool fibers is an important part of the textile industry to add functionality and stability to wool products. In this study, we developed a process utilizing a base/cationic surfactant solution pretreatment followed by an enzyme-mediated keratin crosslinking reaction to modify the wool fibers. Changes in water contact angle demonstrated the successful transformation of the hydrophobic wool surface to a more hydrophilic one after soaking in sodium carbonate solution containing hexadecyltrimethylammonium bromide (CTAB). The treated fabrics were further characterized by colorimetry and fluorescent spectrometry. Results showed that the pretreatment increased the yellowness of fabrics and caused some structural changes among certain amino acids, such as tryptophan and cystine. Keratin extracted from coarse wool fibers was further applied on pretreated fabrics through a microbial transglutaminase (mTGase) mediated reaction under mild conditions. Morphological characterization via SEM demonstrated the effective coverage of keratin on the scales of wool. The current method may provide an alternative processing protocol to modify wool fibers and improve the quality and performance of wool products.

36 MATERIALS SCIENCE↗

Determination of fundamental mechanical properties of biomass using the cubical triaxial tester to model biomass flow

The flowability of biomass is an indicator of how amenable biomass is to handling. The flowability measurements are often determined with empirical or tertiary experiments. This status quo impedes employing engineering principles to advance the design and operation of biomass handling systems. It is imperative to establish an experimental protocol minimizing empirical aspects of flowability characterization to account for the variability of biomass. This study demonstrates the operational principles of the large chamber cubical triaxial tester and the procedure of triaxial tests to quantify bulk flow behaviors of two milled biomass feedstocks, namely corn stover 2 mm (CS) and Douglas fir 1 mm (DF). The Mohr-Coulomb (MC), Drucker-Prager (DP) and modified Cam Clay (mCC) models are calibrated for both biomasses. Analysis indicates that CS will exhibit a cohesive flow with a larger cohesion coefficient of MC (3.8 ± 3.5 kPa) than DF (0.42 ± 0.9 kPa) and a larger d value of DP (6.9 kPa) than DF (0.0 kPa), respectively. CS exhibits a higher spring-back index of mCC (0.39 ± 0.05) than DF (0.27 ± 0.05) also suggesting handling issues, which agrees with the experiences in the industry. This study demonstrates the capability of a CTT in a quantitative investigation of biomass handling characteristics.

09 BIOMASS FUELS↗

High-throughput small-angle X-ray scattering reveals effective structure factor transitions linked to high-concentration antibody viscosity

High-concentration monoclonal antibody (mAb) formulations are often constrained by elevated viscosity, largely driven by protein–protein interactions, which complicates manufacturing and limits subcutaneous delivery. Early viscosity risk assessment is essential during discovery, yet traditional measurements require large sample volumes, and lack high-throughput capability. Here, we develop a high-throughput small-angle X-ray scattering (SAXS) protocol to detect mAb self-association at dilute concentrations, enabling early predictive insights into high-concentration viscosity. Synchrotron SAXS measurements were conducted for 21 mAbs formulated in a histidine buffer at pH 6.0. An initial subset of 10 mAbs analyzed across 1–150 mg/mL revealed that effective structure factor transitions in the low-q region, indicative of interparticle interactions, consistently emerged below 25 mg/mL. Subsequently, 11 additional mAbs were analyzed at 1–25 mg/mL using automated liquid handling and flow cells to enable high-throughput screening. High-viscosity mAbs exhibited detectable low-q upturns at concentrations ≤10 mg/mL, whereas low-viscosity mAbs showed downturns. A classification criterion based on effective structure factor transitions accurately classified all high- and low-viscosity mAbs at 150 mg/mL, offering a scalable, sample-efficient alternative to conventional methods. These results extend recent findings on the concentration-dependent sensitivity of SAXS to short-range attractions, demonstrating that they can emerge at lower concentrations than previously reported. This study presents the most comprehensive and diverse SAXS dataset for mAbs reported to date within a single formulation, providing a valuable resource for developing and validating coarse-grained models that can more accurately capture intermolecular interactions governing high-concentration solution behavior, thereby enabling rational antibody engineering and improved developability.

36 MATERIALS SCIENCE↗

Calcium has a direct effect on thick filament activation in porcine myocardium

Sarcomere activation in striated muscle requires both thin filament–based and thick filament–based activation mechanisms. Recent studies have shown that myosin heads on the thick filaments undergo OFF to ON structural transitions in response to calcium (Ca2+) in permeabilized porcine myocardium in the presence of a small molecule inhibitor that eliminated active force. The changes in X-ray diffraction signatures of OFF to ON transitions were interpreted as Ca2+ acting to activate the thick filaments. Alternatively, Ca2+ binding to troponin could initiate a Ca2+-dependent crosstalk from the thin filament to the thick filament via interfilament connections such as the myosin binding protein-C. Here, we exchanged native troponin in permeabilized porcine myocardium for troponin containing the cTnC D65A mutation, which disallows the activation of troponin through Ca2+ binding to determine if Ca2+-dependent thick filament activation persists in the absence of thin filament activation. After the exchange protocol, over 95% of the Ca2+-activated force was eliminated. Equatorial intensity ratio increased significantly in both WT and D65A exchanged myocardium with increasing Ca2+ concentration. The degree of helical ordering of the myosin heads decreased by the same amount in WT and D65A myocardium when Ca2+ concentration increased. These results are consistent with a direct effect of Ca2+ in activating the thick filament rather than an indirect effect due to Ca2+-mediated crosstalk between the thick and thin filaments.

Physiology↗

Glass/glass photovoltaic module reliability and degradation: a review

Glass/glass (G/G) photovoltaic (PV) module construction is quickly rising in popularity due to increased demand for bifacial PV modules, with additional applications for thin-film and building-integrated PV technologies. G/G modules are expected to withstand harsh environmental conditions and extend the installed module lifespan to greater than 30 years compared to conventional glass/backsheet (G/B) modules. With the rapid growth of G/G deployment, understanding the outdoor performance, degradation, and reliability of this PV module construction becomes highly valuable. In this review, we present the history of G/G modules that have existed in the field for the past 20 years, their subsequent reliability issues under different climates, and methods for accelerated testing and characterization of both cells and packaging materials. We highlight some general trends of G/G modules, such as greater degradation when using poly(ethylene-co-vinyl acetate) (EVA) encapsulants, causing the industry to move toward polyolefin-based encapsulants. Transparent backsheets have also been introduced as an alternative to the rear glass for decreasing the module weight and aiding the effusion of trapped gaseous degradation products in the laminate. New amendments to IEC 61215 standard protocols for G/G bifacial modules have also been proposed so that the rear side power generation and UV exposure will be standardized. We further summarize a suite of destructive and non-destructive characterization techniques, such as current-voltage scans, module electro-optical imaging, adhesion tests, nanoscale structural/chemical investigation, and forensic analysis, to provide deeper insights into the fundamental properties of the module materials degradation and how it can be monitored in the G/G construction. This will set the groundwork for future research and product development.

14 SOLAR ENERGY↗

Influence of electrical field on the susceptibility of gallium nitride transistors to proton irradiation

Radiation susceptibility of electronic devices is commonly studied as a function of radiation energetics and device physics. Often overlooked is the presence or magnitude of the electrical field, which we hypothesize to play an influential role in low energy radiation. Accordingly, we present a comprehensive study of low-energy proton irradiation on gallium nitride high electron mobility transistors (HEMTs), turning the transistor ON or OFF during irradiation. Commercially available GaN HEMTs were exposed to 300 keV proton irradiation at fluences varying from 3.76 × 10 12 to 3.76 × 10 14 cm 2 , and the electrical performance was evaluated in terms of forward saturation current, transconductance, and threshold voltage. The results demonstrate that the presence of an electrical field makes it more susceptible to proton irradiation. The decrease of 12.4% in forward saturation and 19% in transconductance at the lowest fluence in ON mode suggests that both carrier density and mobility are reduced after irradiation. Additionally, a positive shift in threshold voltage (0.32 V and 0.09 V in ON and OFF mode, respectively) indicates the generation of acceptor-like traps due to proton bombardment. high-resolution transmission electron microscopy and energy dispersive x-ray spectroscopy analysis reveal significant defects introduction and atom intermixing near AlGaN/GaN interfaces and within the GaN layer after the highest irradiation dose employed in this study. According to in-situ Raman spectroscopy, defects caused by irradiation can lead to a rise in self-heating and a considerable increase in (∼750 times) thermoelastic stress in the GaN layer during device operation. The findings indicate device engineering or electrical biasing protocol must be employed to compensate for radiation-induced defects formed during proton irradiation to improve device durability and reliability.

gallium nitride↗

Automated characterization of spatial and dynamical heterogeneity in supercooled liquids via implementation of machine learning

Abstract A computational approach by an implementation of the principle component analysis (PCA) with K -means and Gaussian mixture (GM) clustering methods from machine learning algorithms to identify structural and dynamical heterogeneities of supercooled liquids is developed. In this method, a collection of the average weighted coordination numbers ( W C N s ‾ ) of particles calculated from particles’ positions are used as an order parameter to build a low-dimensional representation of feature (structural) space for K -means clustering to sort the particles in the system into few meso-states using PCA. Nano-domains or aggregated clusters are also formed in configurational (real) space from a direct mapping using associated meso-states’ particle identities with some misclassified interfacial particles. These classification uncertainties can be improved by a co-learning strategy which utilizes the probabilistic GM clustering and the information transfer between the structural space and configurational space iteratively until convergence. A final classification of meso-states in structural space and domains in configurational space are stable over long times and measured to have dynamical heterogeneities. Armed with such a classification protocol, various studies over the thermodynamic and dynamical properties of these domains indicate that the observed heterogeneity is the result of liquid–liquid phase separation after quenching to a supercooled state.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Non-equilibrium dynamics in geometrically frustrated spin glass Bi 2 Fe 3 GaO 9 with a Cairo lattice

We have explored the magnetic relaxation of the spin glass phase in Bi 2 Fe 3 GaO 9 , a geometrically frustrated magnet with a unique Cairo lattice made of pentagonal building blocks. Using dc magnetization measurements, we find the relaxation behavior in single crystals follows the Arrhenius law as a function of temperature but remains relatively constant under different magnetic fields. Through a carefully designed protocol, we observe significant rejuvenation and memory effects, reminiscent of classical dilute spin glasses rather than spin jamming systems. Our finding suggests that Bi 2 Fe 3 GaO 9 is probably located in the crossover between conventional spin glass and perfect spin jam and thus provides an excellent platform for investigating the evolution of underlying magnetic structure, paving the way for further neutron scattering research.

aging↗

Fabrication of field-effect transistors with transfer-free nanostructured carbon as semiconducting channel material

Carbon nanostructures as active channel material in field effect transistors (FETs) are appealing in microelectronics for their improved performance such as high speed and low energy dissipation. However, these devices require the incorporation of nanostructure transfer steps in the fabrication process flow, which makes difficult its application in large scale integration circuits. Here we present a novel method for the fabrication of FETs with nanostructured carbon in the channel with p-type semiconducting properties and intermediate drain-source current (IDS) on/off ratio. The method is based on the use of Ni nanoparticles in the source-drain gap region as seed material for the formation of carbon nanostructures in the FET channel. FETs without Ni nanoparticles in the channel showed no modulation of IDS as a function of gate voltage. The device fabrication process does not require any carbon nanostructure transfer steps since it directly forms carbon nanostructures electrically connected to the device's source and drain electrodes via electron-beam evaporation of carbon and conventional lithographic processes. Since all device fabrication steps are compatible with Si technology processes, they are capable of being further optimized following process development protocols practiced by the semiconductor industry.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Mechanical studies of the solid electrolyte interphase on anodes in lithium and lithium ion batteries

A stable solid electrolyte interphase (SEI) layer is key to high performing lithium ion batteries for metrics such as calendar and cycle life. The SEI must be mechanically robust to withstand large volumetric changes in anode materials such as lithium and silicon, so understanding the mechanical properties and behavior of the SEI is essential for the rational design of artificial SEI and anode form factors. The mechanical properties and mechanical failure of the SEI are challenging to study, because the SEI is thin at only ~ 10 – 200 nm thick and is air sensitive. Furthermore, the SEI changes as a function of electrode material, electrolyte and additives, temperature, potential, and formation protocols. A variety of in situ and ex situ techniques have been used to study the mechanics of the SEI on a variety of lithium ion battery anode candidates; however, there hasn't been a succinct review of the findings thus far. Because of the difficultly of isolating the true SEI and its mechanical properties, there have been a limited number of studies that can fully de-convolute the SEI from the anode it forms on. A review of past research will be helpful for culminating current knowledge and helping to inspire new innovations to better quantify and understand the mechanical behavior of the SEI. This review will summarize the different experimental and theoretical techniques used to study the mechanics of SEI on common lithium ion battery anodes and their strengths and weaknesses.

25 ENERGY STORAGE↗

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN↗

Trapped flux in pure and Mn-substituted CaKFe 4 As 4 and MgB 2 superconducting single crystals

Abstract Measurements of temperature dependent magnetization associated with trapped magnetic flux in single crystals of CaKFe 4 As 4 , CaK(Fe 0.983 Mn 0.017 ) 4 As 4 and MgB 2 using zero-field-cooled and field-cooled protocols are presented. The results allow for the determination of the values of superconducting transition temperature, lower critical field and self-field critical current density. These are compared with the literature data. Possible experimental concerns are briefly outlined. Our results, on these known superconductors at ambient pressure, are qualitatively similar to those recently measured on superhydrides at megabar pressures (Minkov et al 2023 Nat. Phys. https://doi.org/10.1038/s41567-023-02089-1 ) and, as such, hopefully serve as a baseline for the interpretation of high pressure, trapped flux measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Trapped flux in a small crystal of CaKFe 4 As 4 at ambient pressure and in a diamond anvil pressure cell

In an extension of our previous work, the measurements of temperature dependent magnetization associated with trapped magnetic flux in a small single crystal of CaKFe 4 As 4 , using zero - field - cooled and field - cooled protocols were performed, on the same crystal, at ambient pressure without a pressure cell and at 2.2 GPa in a commercial diamond anvil cell (DAC), showing comparable results. The data show that with a proper care and understanding, trapped flux measurements in superconductors indeed can be performed on samples in DACs under pressure, as was done on superhydrides.

36 MATERIALS SCIENCE↗