Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power optimizer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Multi-Stage Modeling With Recourse Decisions for Solving Stochastic Complementarity Problems With an Application in Energy

This paper presents a multi-stage model with recourse decisions for solving complementarity problems in a competitive electricity market under uncertainty, while also considering renewable energy technologies and battery storage utilization. The model is based on a Nash-Cournot formulation of imperfect competition among power producers. We analyze the value of variable renewable energy (VRE) and battery storage under different uncertainties, such as demand level and VRE availability. To illustrate the proposed model, we apply it to three- bus five-player model and analyze different cases varying costs, including a user-optimal perspective (with market power) and a system-optimal perspective (with central planning). We also consider the potential for congestion in the system by restricting the transmission capacity between a single interface that connects two buses. Our findings show that increasing the battery storage capacity results in a decrease in the need for perfect information about future uncertainties. Additionally, as the model allows for more uncertainty, it becomes more apparent that the stochastic mixed complementarity problem (MCP) has an advantage over a deterministic equivalent. We propose the use of the Value of the Stochastic Equilibrium Solution (VSES) as a quality metric to compare the stochastic MCP with its deterministic equivalent. Overall, expanding battery storage capacity can lower the maximum, mean, and variance values of delivered prices, but there are diminishing returns to this approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Simple Crunching of the AGS "bare" machine ORM Data - February 2007 - to extract some aspects of AGS Transverse Coupling at Injection and Extraction

The objective of this note is to (once again) explore the AGS “ORM” (orbit response matrix) data taken (by Operations) early during the 2007 run with an AGS bare machine and gold beam. Indeed the present motivation is to extract as much information about the AGS inherent transverse coupling as possible - from general arguments and the copious ORM data. And taking this one step further, (though not accomplished yet) the goal really should be to tell the model how to describe this coupling. “Bare” as used here means the AGS with no quadrupole, sextupole or octupole magnets powered. Only the main (combined-function) magnet string and dipole bumps necessary to optimize beam survival are powered. “ORM data” means the systematic recording of the equilibrium orbit beam position monitor response to powering individual dipole corrector magnets. The “matrix” results from looking at the effect of each of the (12 superperiods X 4 dipoles per superperiod) “kicks” on each of the (12 X 6) pick up electrodes (pues) in each transverse plane. So then we have two (48X72) matrices of numbers from the ORM data. (Though “pue” usually refers to the hardware in the vacuum chamber and “bpm” to the beam position monitoring system, the two labels will be used casually here.) The exercise is carried out at two magnet rigidities, injection (AGS field ~434 Gauss) and extraction to RHIC (~9730 Gauss), - a ratio of rigidities of about 22.4. Since we stick with a bare machine, we are also stuck with the bare tunes which means the tunes are rather close together and near 8.75. (Injection : (h,v) ~ (8.73, 8.76).

43 PARTICLE ACCELERATORS↗

Computational fluid dynamics modeling of two-phase flow in a BWR fuel assembly. Final CRADA Report.

A direct numerical simulation capability for two-phase flows with heat transfer in complex geometries can considerably reduce the hardware development cycle, facilitate the optimization and reduce the costs of testing of various industrial facilities, such as nuclear power plants, steam generators, steam condensers, liquid cooling systems, heat exchangers, distillers, and boilers. Specifically, the phenomena occurring in a two-phase coolant flow in a BWR (Boiling Water Reactor) fuel assembly include coolant phase changes and multiple flow regimes which directly influence the coolant interaction with fuel assembly and, ultimately, the reactor performance. Traditionally, the best analysis tools for this purpose of two-phase flow phenomena inside the BWR fuel assembly have been the sub-channel codes. However, the resolution of these codes is too coarse for analyzing the detailed intra-assembly flow patterns, such as flow around a spacer element. Advanced CFD (Computational Fluid Dynamics) codes provide a potential for detailed 3D simulations of coolant flow inside a fuel assembly, including flow around a spacer element using more fundamental physical models of flow regimes and phase interactions than sub-channel codes. Such models can extend the code applicability to a wider range of situations, which is highly important for increasing the efficiency and to prevent accidents.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A simple crunching of the AGS 'bare' machine ORM data - February 2007 - to extract some aspects of AGS transverse coupling at injection and extraction

The objective of this note is to (once again) explore the AGS 'ORM' (orbit response matrix) data taken (by Operations) early during the 2007 run with an AGS bare machine and gold beam. Indeed the present motivation is to extract as much information about the AGS inherent transverse coupling as possible - from general arguments and the copious ORM data. And taking this one step further, (though not accomplished yet) the goal really should be to tell the model how to describe this coupling. 'Bare' as used here means the AGS with no quadrupole, sextupole or octupole magnets powered. Only the main (combined-function) magnet string and dipole bumps necessary to optimize beam survival are powered. 'ORM data' means the systematic recording of the equilibrium orbit beam position monitor response to powering individual dipole corrector magnets. The 'matrix' results from looking at the effect of each of the (12 superperiods X 4 dipoles per superperiod) 'kicks' on each of the (12 X 6) pick up electrodes (pues) in each transverse plane. So then we have two (48 X 72) matrices of numbers from the ORM data. (Though 'pue' usually refers to the hardware in the vacuum chamber and 'bpm' to the beam position monitoring system, the two labels will be used casually here.) The exercise is carried out at two magnet rigidities, injection (AGS field {approx}434 Gauss) and extraction to RHIC ({approx}9730 Gauss), - a ratio of rigidities of about 22.4. Since we stick with a bare machine, we are also stuck with the bare tunes which means the tunes are rather close together and near 8.75. Injection: (h,v) {approx} (8.73, 8.76).

43 PARTICLE ACCELERATORS↗

Automated Power-Distribution System

Autonomous power-distribution system includes power-control equipment and automation equipment. System automatically schedules connection of power to loads and reconfigures itself when it detects fault. Potential terrestrial applications include optimization of consumption of power in homes, power supplies for autonomous land vehicles and vessels, and power supplies for automated industrial processes.

Ashworth, Barry↗

Cloud-based control for power distribution system

Unique systems, methods, techniques and apparatuses for cloud-based control for power distribution systems are disclosed. One exemplary embodiment is a system comprising a microprocessor-based power management system in operative communication with a plurality of buildings located remotely from the power management system and a plurality of communication interface devices provided at corresponding ones of the plurality of buildings. The power management system is structured to perform a plurality of building unit-specific optimizations, evaluate a net power demand on the electrical power grid, reduce the net power demand on the electrical power grid while minimizing disruption to the resident-defined preference parameters, and transmit to each of the plurality of interface devices the one or more additional control commands corresponding to the specific building at which each interface device is provided.

Feng, Xiaoming↗

Small high cooling power space cooler

The small High Efficiency pulse tube Cooler (HEC) cooler, that has been produced and flown on a number of space infrared instruments, was originally designed to provide cooling of 10 W @ 95 K. It achieved its goal with >50% margin when limited by the 180 W output ac power of its flight electronics. It has also been produced in 2 stage configurations, typically for simultaneously cooling of focal planes to temperatures as low as 35 K and optics at higher temperatures. The need for even higher cooling power in such a low mass cryocooler is motivated by the advent of large focal plane arrays. With the current availability at NGAS of much larger power cryocooler flight electronics, reliable long term operation in space with much larger cooling powers is now possible with the flight proven 4 kg HEC mechanical cooler. Even though the single stage cooler design can be re-qualified for those larger input powers without design change, we redesigned both the linear and coaxial version passive pulse tube cold heads to re-optimize them for high power cooling at temperatures above 130 K while rejecting heat to 300 K. Small changes to the regenerator packing, the re-optimization of the tuned inertance and no change to the compressor resulted in the increased performance at 150 K. The cooler operating at 290 W input power achieves 35 W@ 150 K corresponding to a specific cooling power at 150 K of 8.25 W/W and a very high specific power of 72.5 W/Kg. At these powers the cooler still maintains large stroke, thermal and current margins. In this paper we will present the measured data and the changes to this flight proven cooler that were made to achieve this increased performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation and Demonstration of Control System Functional Capabilities within the IES Plug-and-Play Simulation Environment

The concept of an integrated energy system (IES) is meant to combine different energy technologies in synergistic ways to achieve a more secure and economical energy supply. The RAVEN-based HYBRID framework is used to find the optimal installed capacity and the optimal economical dispatch of each component of the IES. The new RAVEN plugin for grid and capacity optimization (HERON) only addresses the limits that affect the production variables and the corresponding rates of variation (explicit constraints). However, other variables are subject to constraints, and the associated limits should be accounted for (implicit constraints). In particular, for the power dispatch problem, the optimization algorithm takes into account the limits on the electrical power output and the corresponding hourly power variations but does not consider other constraints on process variables whose response affects the service life of the IES. This report describes a scheme that allows accounting for implicit constraints without increasing the size of the optimization problem. To obtain a more accurate approximation of the nonlinear dynamic behavior, a parametric version of the dynamic mode decomposition with control (DMDc) algorithm was developed to derive the state-space representation matrices of the IES components at different scheduling parameter. Thanks to this approach, a more accurate approximation of the system response can be obtained, the limits imposed by thermal mechanical implicit constraints can be translated into power dispatch limits, and the feedbacks to HERON power dispatcher can be provided. To assess the developed methodology, a power dispatching test case composed of three power generating and storage units (Balance of Plant, Secondary Energy Source, Thermal Energy Storage) was developed. The power output of each one of the three units was optimized to meet the imposed time-dependent load demand trajectory and to maximize the IES profitability by meeting both the explicit and implicit constraints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydrodynamic Optimization Method and Design Code for Stall-Regulated Hydrokinetic Turbine Rotors

This report describes the adaptation of a wind turbine performance code for use in the development of a general use design code and optimization method for stall-regulated horizontal-axis hydrokinetic turbine rotors. This rotor optimization code couples a modern genetic algorithm and blade-element momentum performance code in a user-friendly graphical user interface (GUI) that allows for rapid and intuitive design of optimal stall-regulated rotors. This optimization method calculates the optimal chord, twist, and hydrofoil distributions which maximize the hydrodynamic efficiency and ensure that the rotor produces an ideal power curve and avoids cavitation. Optimizing a rotor for maximum efficiency does not necessarily create a turbine with the lowest cost of energy, but maximizing the efficiency is an excellent criterion to use as a first pass in the design process. To test the capabilities of this optimization method, two conceptual rotors were designed which successfully met the design objectives.

17 WIND ENERGY↗

Fourier Analysis and Loss Modeling for Inductive Wireless Electric Vehicle Charging with Reduced Stray Field

With the growth of electric vehicle (EV) popularity, different charging options to increase user convenience and reduce charging times are being considered and researched. Among these, inductive wireless power transfer (WPT) systems for EVs are being designed to meet specifications such as stray field, power level, efficiency, misalignment tolerance, and ground clearance, which are all heavily influenced by the coil geometry. The proposed Fourier Analysis Method (FAM) is an analytical method to directly design coil geometries to meet stray field and power level requirements through an optimization of Fourier basis function coefficients. The outputs of the optimization are complex, planar coil geometries that meet the power level and stray field constraints with minimized loss factors. Contours of these potentials determine the coil conductor paths and loss models predict the system efficiency and performance over misalignment. The Fourier representation of the geometry is used to conveniently calculate the coupling over misalignment, external proximity effect loss, and ferrite loss. A 6.6 kW prototype WPT system with low stray field and high efficiency is built from the optimization results to validate the models and showcase the usefulness of the FAM design approach.

33 ADVANCED PROPULSION SYSTEMS↗

Optimization of Component Sizing for a Fuel Cell-Powered Truck to Minimize Ownership Cost

In this study, we consider fuel cell-powered electric trucks (FCETs) as an alternative to conventional medium- and heavy-duty vehicles. FCETs use a battery combined with onboard hydrogen storage for energy storage. The additional battery provides regenerative braking and better fuel economy, but it will also increase the initial cost of the vehicle. Heavier reliance on stored hydrogen might be cheaper initially, but operational costs will be higher because hydrogen is more expensive than electricity. Achieving the right tradeoff between these power and energy choices is necessary to reduce the ownership cost of the vehicle. This paper develops an optimum component sizing algorithm for FCETs. The truck vehicle model was developed in Autonomie, a platform for modelling vehicle energy consumption and performance. The algorithm optimizes component sizes to minimize overall ownership cost, while ensuring that the FCET matches or exceeds the performance and cargo capacity of a conventional vehicle. Class 4 delivery truck and class 8 linehaul trucks are shown as examples. We estimate the ownership cost for various hydrogen costs, powertrain components, ownership periods, and annual vehicle miles travelled.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimal Sizing of Resilience Solutions for the U.S. Army Reserve

Power or water outages in buildings threaten the ability of the military to support surrounding communities during natural disasters. Outages can last for days, weeks or months. Typical solutions include very expensive batteries and onsite generation that are sized based on historical power needs. The U.S. Army Reserve (USAR) has teamed up with the Pacific Northwest National Laboratory (PNNL) to develop a simulation framework that optimizes future power needs to reduce the cost of resilience solutions. The approach starts with the building. Power needs during an emergency event are simulated at the building end-use level, then loads are reduced through the selection of life cycle cost-effective building-level technology improvements. These new optimized loads are then fed into a microgrid sizing tool that dynamically constructs many different combinations of solar photovoltaic, battery storage, and generator resources to meet the load for hundreds of statistically generated outage scenarios. Six site assessments completed by USAR and PNNL in 2019 have resulted in a 1-14% reduction in overall investment when optimizing the buildings first before determining the generation requirements. This approach helps the Army secure critical missions and provide a 14 day-minimum supply of necessary energy and water in the most efficient manner.

buidlings, efficiency, resilience, FEDS, MCOR↗

The Atacama Cosmology Telescope: The Polarization-Sensitive ACTPol Instrument

The Atacama Cosmology Telescope (ACT) makes high angular resolution measurements of anisotropies in the Cosmic Microwave Background (CMB) at millimeter wavelengths. We describe ACTPol, an upgraded receiver for ACT, which uses feedhorn-coupled, polarization-sensitive detector arrays, a 3° field of view, 100 mK cryogenics with continuous cooling, and meta material antireflection coatings. ACTPol comprises three arrays with separate cryogenic optics: two arrays at a central frequency of 148 GHz and one array operating simultaneously at both 97 GHz and 148 GHz. The combined instrument sensitivity, angular resolution, and sky coverage are optimized for measuring angular power spectra, clusters via the thermal Sunyaev–Zel'dovich (SZ) and kinetic SZ signals, and CMB lensing due to large-scale structure. The receiver was commissioned with its first 148 GHz array in 2013, observed with both 148 GHz arrays in 2014, and has recently completed its first full season of operations with the full suite of three arrays. This paper provides an overview of the design and initial performance of the receiver and related systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Core loading pattern optimization of thorium fueled heavy water breeder reactor using genetic algorithm

In this work genetic algorithm was proposed to solve fuel loading pattern optimization problem in thorium fueled heavy water reactor. The objective function of optimization was to maximize the conversion ratio and minimize power peaking factor. Those objectives were simultaneously optimized using non-dominated Pareto-based population ranking optimal method. Members of non-dominated population were assigned selection probabilities based on their rankings in a manner similar to Baker's single criterion ranking selection procedure. A selected non-dominated member was bred through simple mutation or one-point crossover process to produce a new member. The genetic algorithm program was developed in FORTRAN 90 while neutronic calculation and analysis was done by COREBN code, a module of core burn-up calculation for SRAC. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimizing the physical design and layout of a resilient wind, solar, and storage hybrid power plant

We report as wind and solar technologies improve and their costs decrease, the share of power produced by these sources will increase. As the market penetration increases, these power sources will need to provide grid services, such as dispatchability, in addition to providing energy. One way to reduce variability, provide higher quality power to the grid, and address local grid stability issues is through colocating wind and solar power plants. In addition to operating reliably during normal operating conditions, in scenarios with high penetrations of renewable generation, it is important that these hybrid plants can withstand production disruptions and continue to supply power despite prolonged resource reduction, extreme weather events, or other disruptions. In this paper, we present a methodology to optimize a wind-solar-battery hybrid power plant down to the component level that is resilient against production disruptions and that can continually produce some minimum required power. We introduce the models and assumptions we used to simulate a hybrid power plant as well as the design variable parameterization and specific methods we used to optimize the plant. We demonstrate the performance of our method by comparing a plant optimized for different objectives, generation outage durations, minimum power requirements, and power purchase agreements. Although the plant design is sensitive to model parameters and various other assumptions, our results demonstrate some of the optimal designs that occur in different scenarios and what one should expect when designing a hybrid wind-solar-storage power plant.

14 SOLAR ENERGY↗

HIRS-AMTS satellite sounding system test - Theoretical and empirical vertical resolving power

The present investigation is concerned with the vertical resolving power of satellite-borne temperature sounding instruments. Information is presented on the capabilities of the High Resolution Infrared Radiation Sounder (HIRS) and a proposed sounding instrument called the Advanced Moisture and Temperature Sounder (AMTS). Two quite different methods for assessing the vertical resolving power of satellite sounders are discussed. The first is the theoretical method of Conrath (1972) which was patterned after the work of Backus and Gilbert (1968) The Backus-Gilbert-Conrath (BGC) approach includes a formalism for deriving a retrieval algorithm for optimizing the vertical resolving power. However, a retrieval algorithm constructed in the BGC optimal fashion is not necessarily optimal as far as actual temperature retrievals are concerned. Thus, an independent criterion for vertical resolving power is discussed. The criterion is based on actual retrievals of signal structure in the temperature field.

Thompson, O. E.↗

Enhanced power factor and high-pressure effects in (Bi,Sb){sub 2}(Te,Se){sub 3} thermoelectrics

We investigated the effects of applied high pressure on thermoelectric, electric, structural, and optical properties of single-crystalline thermoelectrics, Bi{sub 2}Te{sub 3}, Bi{sub x}Sb{sub 2−x}Te{sub 3} (x = 0.4, 0.5, 0.6), and Bi{sub 2}Te{sub 2.73}Se{sub 0.27} with the high thermoelectric performance. We established that moderate pressure of about 2–4 GPa can greatly enhance the thermoelectric power factor of all of them. X-ray diffraction and Raman studies on Bi{sub 2}Te{sub 3} and Bi{sub 0.5}Sb{sub 1.5}Te{sub 3} found anomalies at similar pressures, indicating a link between crystal structure deformation and physical properties. We speculate about possible mechanisms of the power factor enhancement and suppose that pressure/stress tuning can be an effective tool for the optimization of the thermoelectric performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗