Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Oregon Offshore Wind Site Feasibility and Cost Study

The work performed in this Oregon study assessed the present and future costs of floating offshore wind technology deployment in the state of Oregon at commercial scale. It is widely recognized that floating offshore wind energy technology will be needed if significant offshore wind deployment in the Pacific region is to occur. The study was performed by the National Renewable Energy Laboratory (NREL) and its subcontractors and funded by the Bureau of Ocean Energy Management (BOEM). It was based, in part, on assumptions and analysis from an NREL report titled 'A Spatial-Economic Cost-Reduction Pathway Analysis for U.S. Offshore Wind Energy Development from 2015-2030' (Beiter et al. 2016), which supported the 'National Offshore Wind Strategy' (Gilman et al. 2016). The strategy builds on the previous DOE Wind Vision Study Scenario of 86 gigawatts (GW) of offshore wind deployed by 2050 in the United States. Under the Wind Vision scenario, 20% (17.2 GW installed capacity) of the nation's total offshore wind in 2050 comes from the Pacific coastal states (DOE 2015), which will require the development of floating wind technologies. Although most offshore development to date has been in depths of 50 meters (m) or less, 97% of Oregon's offshore wind resource is in water depths greater than 60 m, where floating wind is assumed to be needed. Floating offshore wind technology is still in its nascent stage of development but is advancing toward commercialization in both Europe and Asia. In this report, we use available floating prototype costs, pilot-scale costs, and commercial-scale costs from fixed-bottom offshore wind projects to model and analyze the cost of floating wind for five hypothetical wind sites in Oregon using specific geographical and utility grid information.

17 WIND ENERGY↗

Supersonic civil airplane study and design: Performance and sonic boom

Since aircraft configuration plays an important role in aerodynamic performance and sonic boom shape, the configuration of the next generation supersonic civil transport has to be tailored to meet high aerodynamic performance and low sonic boom requirements. Computational fluid dynamics (CFD) can be used to design airplanes to meet these dual objectives. The work and results in this report are used to support NASA's High Speed Research Program (HSRP). CFD tools and techniques have been developed for general usages of sonic boom propagation study and aerodynamic design. Parallel to the research effort on sonic boom extrapolation, CFD flow solvers have been coupled with a numeric optimization tool to form a design package for aircraft configuration. This CFD optimization package has been applied to configuration design on a low-boom concept and an oblique all-wing concept. A nonlinear unconstrained optimizer for Parallel Virtual Machine has been developed for aerodynamic design and study.

Cheung, Samson↗

FCC feasibility studies: Impact of tracker- and calorimeter-detector performance on jet flavor identification and Higgs physics analyses

The ambitious physics program planned for the Future Circular Collider electron-positron phase imposes stringent constraints on detector performance. This study systematically investigates how different detector configurations impact jet flavor identification and their effects on high-profile physics analyses. Using Higgs boson coupling measurements and searches for invisible Higgs decays as benchmarks, we evaluate the sensitivity of these analyses to variations in tracker and calorimeter detector properties. We examine modifications to single-point resolution, material budget, silicon layer placement, and particle identification capabilities, quantifying their effects on flavor-tagging performance. Additionally, we present the first comprehensive study of Higgs-to-invisible decay detection using full detector simulation, providing insights for optimizing detector designs at lepton colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Urban microclimate and its impact on building performance: A case study of San Francisco

Urban microclimate exerts an increasing influence on urban buildings, energy, and sustainability. This study uses 10-year measured hourly weather data at 27 sites in San Francisco, California, to (1) analyze and visualize the urban microclimate patterns and urban heat island effect; (2) simulate annual energy use and peak electricity demand of typical large office buildings and large hotels to investigate the influence of urban microclimate on building performance; (3) simulate indoor air temperature of a single-family house without air-conditioning during the record three-day heatwave of 2017, to quantify the divergence of climate resilience due to urban microclimate effect. Results show significant microclimate effects in San Francisco with up to 11 °C outdoor air temperature difference between the coastal and downtown areas on September 1, 2017, during the record three-day heatwave. The simulated energy results of the prototype large office and large hotel buildings using the 2017 weather data show over 100% difference in annual heating energy use and 65% difference in annual cooling energy use across different stations; as well as up to 30% difference in peak cooling electricity demand. The impacts on annual site or source energy use are minimal (less than 5%) as cooling and heating in a mild climate are a relatively small portion of overall building energy use in San Francisco. Results also show the microclimate effects influence indoor air temperature of unconditioned homes by up to 5 °C. Newer buildings and homes are much less affected by microclimate effects due to more stringent performance requirements of the building envelope and energy systems. Furthermore, these findings inform that San Francisco microclimate variations should be considered in urban energy planning, building energy codes and standards, as well as heat resilience policymaking.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Performance Computing Productivity Study - Evaluation of Parallel Tools Platform (PTP) Eclipse Plug-In

This report is a DARPA funded Work For Others (WFO) evaluation of the Parallel Tools Platform (PTP) version 5.0.3 (Released October 18, 2011). PTP is currently being developed and supported as an open source product managed by Project Lead Greg Watson and team at IBM plus several other contributors. The tool has been in development since 2005 with a goal of providing an infrastructure for the integration of high performance computing tools. Basic functionality such as source code editing, compiling, launching, and debugging, plus more advanced features including performance monitoring and deployment have been bundled into an Eclipse Integrated Development Environment (IDE) plug-in to give parallel application programmers the features and improved productivity gained from using a common, well established development platform. The evaluation encompasses the basic aspects of using PTP, beginning with the installation and configuration of the plug-in, followed by code development and debugging. Each aspect is evaluated based on the expectations of my experience as an Eclipse user and is presented in the following format: • Feature description • User Experience • Evaluation The feature description is based on the provided documentation for PTP and the ‘generic’ expectations of what the feature should provide. The user experience reveals the actual use and exercise of the feature – specifically in the context and perspective of the evaluation platform provided by Lawrence Livermore National Laboratory. The evaluation of each feature includes the overall outcome of the user experience, along with the expectations that were not met, met, or exceeded along with any issues that were encountered.

97 MATHEMATICS AND COMPUTING↗

Uranium Ion Exchange Resin Performance - A Case Study at 200 West Pump and Treat - 18103

The 200 West Pump and Treat Facility (200W P and T), located on the U.S. Department of Energy's Hanford site, is a 2,500 gallon per minute (GPM) plant designed to capture and treat an eight square kilometer groundwater plume. The groundwater contamination is largely a result of process liquids disposed from operations involving the separation of nuclear materials and storage of spent nuclear fuel. This document will report on the performance of a full scale uranium ion exchange system used to treat contaminated groundwater and other waste streams. The uranium ion exchange system at 200W P and T was designed as a three vessel operation with a lead, lag and polish vessel, which contain 300 cubic feet of resin in each vessel. The ion exchange system treats a portion of the total plant flow with a maximum capacity of 400 GPM. Prior to start-up, one key issue was the potential to treat feed streams with a wide range of uranium concentrations (22 to 150,000 microgram per liter [μg/L]). The resin change-out frequency was a primary concern. A literature review was performed, resulting in resin capacity and change out frequency that varied by two orders of magnitude (1.2 milligram per gram [mg/g] to 104 mg/g capacity). Since startup in September 2015, the ion exchange system has experienced a dynamic feed stream as wells were brought online, which changed the contaminant concentrations. The plant also treats leachate liquid waste from on-site low-level waste site, known as the Environmental Restoration Disposal Facility (ERDF), which contains uranium as well as other competing anions, such as sulfate. The uranium breakthrough is closely monitored throughout the resin beds with weekly sampling events at the influent, effluent, and intermediate ports in the first vessel. In the influent to the ion exchange system, the uranium concentration fluctuated from 24 μg/L up to 910 μg/L. The information on influent and effluent was used to determine the change out frequency and the capacity of the resin for uranium under these operating conditions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On-line maintenance methodology development and its applications

With the increasing economic pressures being faced and the potential for shortening outage times under the conditions of deregulated electricity markets in the world, licensees are motivated to get an increasing amount of the on-line maintenance (OLM). The benefits of the OLM includes increased system and plant reliability, reduction of plant equipment and system material condition deficiencies that could adversely impact operations, and reduction of work scope during plant refueling outages. In Korea, allowance guidelines of risk assessment is specified in the safety regulation guidelines 16.7 and 16.8 of the Korea Inst. of Nuclear Safety (KINS), which is 'General guidelines of Risk-informed application for requesting permission of changes' and 'Requesting permission of changes of Risk-informed application for Technical Specification'. We select the emergency diesel generator (EDG) of the Ulchin unit 3 and 4 for risk assessment analysis by applying configuration changes. The EDG which has plant safety level IE belongs to on-site standby power (A, B train EDG) in electric distribution system. The EDG is important component because it should maintain standby status during plant is operating, therefore we select the EDG for target component of risk assessment analysis. The risk assessment is limited to CDF. The risk assessment is performed by using AIMS-PSA Release2. We evaluate CDF by applying the configuration changes with some assumptions. Evaluation of the full power operation and Low power/Shut down operation was performed. This study has been performed for introducing a methodology and performing risk assessment. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Supersonic fan engines for military aircraft

Engine performance and mission studies were performed for turbofan engines with supersonic through-flow fans. A Mach 2.4 CTOL aircraft was used in the study. Two missions were considered: a long range penetrator mission and a long range intercept mission. The supersonic fan engine is compared with an augmented mixed flow turbofan in terms of mission radius for a fixed takeoff gross weight of 75,000 lbm. The mission radius of aircraft powered by supersonic fan engines could be 15 percent longer than aircraft powered with conventional turbofan engines at moderate thrust to gross weight ratios. The climb and acceleration performance of the supersonic fan engines is better than that of the conventional turbofan engines.

Franciscus, L. C.↗

Supersonic fan engines for military aircraft

Engine performance and mission studies were performed for turbofan engines with supersonic through-flow fans. A Mach 2.4 CTOL aircraft was used in the study. Two missions were considered: a long range penetrator mission and a long range intercept mission. The supersonic fan engine is compared with an augmented mixed flow turbofan in terms of mission radius for a fixed takeoff gross weight of 75,000 lbm. The mission radius of aircraft powered by supersonic fan engines could be 15 percent longer than aircraft powered with conventional turbofan engines at moderate thrust to gross weight ratios. The climb and acceleration performance of the supersonic fan engines is better than that of the conventional turbofan engines. Previously announced in STAR as N83-34947

Franciscus, L. C.↗

A study of hypersonic swept shock wave/turbulent boundary layer interactions using a conical Navier-Stokes code

A computational study has been performed of sharp fin-induced swept shock wave/turbulent boundary layer interactions at low hypersonic Mach numbers. The objective was to determine if results obtained using a conical Navier-Stokes code, particularly the peak heating and pressure, are adequate for engineering predictions. The advantage of the conical approach is that the problem becomes two-dimensional and requires much less computational effort than a fully three-dimensional calculation. In this code, the standard Baldwin-Lomax model is used for turbulent closure and its performance is studied in some detail. To assess the approach interactive flowfields generated by unswept sharp fins at two angles of attack at each of three hyprsonic freestream Mach numbers (5, 6, 11) have been calculated and the results compared with experimental wall pressure and heat transfer data. Although the conical Navier-Stokes/Baldwin-Lomax approach is reasonably successful at Mach numbers up to 5, the performance deteriorates as the Mach number is increased. Nevertheless, the approach could be a valuable tool in preliminary parametric design studies.

Rodi, Patrick E.↗

Performance and control study of a low-pressure-ratio turbojet engine for a drone aircraft

The results of analog and digital computer studies of a low-pressure-ratio turbojet engine system for use in a drone vehicle are presented. The turbojet engine consists of a four-stage axial compressor, single-stage turbine, and a fixed area exhaust nozzle. Three simplified fuel schedules and a generalized parameter fuel control for the engine system are presented and evaluated. The evaluation is based on the performance of each schedule or control during engine acceleration from a windmill start at Mach 0.8 and 6100 meters to 100 percent corrected speed. It was found that, because of the higher acceleration margin permitted by the control, the generalized parameter control exhibited the best dynamic performance.

Seldner, K.↗

IMPACT OF AIR LEAKAGE THROUGH RECESS LIGHTING FIXTURES ON THE ENERGY PERFORMANCE OF RESIDENTIAL BUILDINGS–A CASE STUDY

The actual energy performance of buildings depends on not only the design criteria but also on the construction quality of buildings. Many design assumptions can be invalidated by unexpected construction quality issues, and lead to large variations between the designed performance and the constructed performance. Though important, very limited research, especially quantitative study, is found on evaluating the impact of construction quality issues on building energy performance. In this paper the construction quality issues of residential buildings in the United States is discussed, along with reviews of building envelope related research. A case study on residential attic construction is presented to illustrate how construction quality affects the energy performance of attics. The case study utilized 3D computational fluid dynamics to simulate air leakage issues in recessed lighting using different boundary conditions. The results of the case study suggest that some seemingly insignificant construction quality issue can cause significant increase in energy consumption of residential buildings. The paper provides scientific evidence to help residential construction industry to improve the construction quality of residential buildings in the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of Z{sub 1/2}, EH{sub 5}, and Ci1 deep defects on the performance of n-type 4H-SiC epitaxial layers Schottky detectors: Alpha spectroscopy and deep level transient spectroscopy studies

Spectroscopic performance of Schottky barrier alpha particle detectors fabricated on 50 μm thick n-type 4H-SiC epitaxial layers containing Z{sub 1/2}, EH{sub 5}, and Ci1 deep levels were investigated. The device performance was evaluated on the basis of junction current/capacitance characterization and alpha pulse-height spectroscopy. Capacitance mode deep level transient spectroscopy revealed the presence of the above-mentioned deep levels along with two shallow level defects related to titanium impurities (Ti(h) and Ti(c)) and an unidentified deep electron trap located at 2.4 eV below the conduction band minimum, which is being reported for the first time. The concentration of the lifetime killer Z{sub 1/2} defects was found to be 1.7 × 10{sup 13} cm{sup −3}. The charge transport and collection efficiency results obtained from the alpha particle pulse-height spectroscopy were interpreted using a drift-diffusion charge transport model. Based on these investigations, the physics behind the correlation of the detector properties viz., energy resolution and charge collection efficiency, the junction properties like uniformity in barrier-height, leakage current, and effective doping concentration, and the presence of defects has been discussed in details. The studies also revealed that the dominating contribution to the charge collection efficiency was due to the diffusion of charge carriers generated in the neutral region of the detector. The 10 mm{sup 2} large area detectors demonstrated an impressive energy resolution of 1.8% for 5486 keV alpha particles at an optimized operating reverse bias of 130 V.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Summary of Geometric Parameters and Their Effects on Performance of U-10Mo Fuel Plates

A monolithic plate-type fuel system has been under development to convert high-performance test reactors from highly enriched uranium to low-enrichment uranium fuels and is now moving into the qualification phase, a predecessor to the timely conversion of the target reactors. To qualify this fuel system, the plates must meet safety standards and perform well in a reactor. The plates must maintain mechanical integrity, exhibit geometric stability, and have stable and predictable in-reactor behavior. The requirement to maintain mechanical integrity under normal operating conditions is primarily demonstrated by successful testing. However, each high-performance reactor employs a distinct design, resulting in distinct plate geometries, with unique features, attributes, irregularities, and tolerances. Due to the abundance of such distinct geometric varieties, a single “generic” plate geometry capturing all extremes is not achievable. It is also impractical to test each of these proposed designs in a reactor. This limitation necessitates cautious evaluations since the thermomechanical response of a plate with a certain geometry may not be representative for a plate with a significantly different geometry. To address concerns related to in-reactor plate performance, large set of sensitivity studies were performed. These parametric studies aimed to better understand irradiation performance, while evaluating the sensitivity of results to various modeling inputs, including geometric, operational, and material parameters. This work studied selected geometric parameters based on provided fuel specifications and performed a series of parametric simulations. The resulting temperature, displacement, and stress strains were comparatively evaluated to determine the effects of various geometric parameters. This draft provides a “high-level summary” of our parametric sensitivity studies and summarizes the key findings.

42 ENGINEERING↗

A critical examination of expansion tunnel performance

An experimental study of the performance of the expansion tunnel for various test gases and range of quiescent acceleration section and nozzle pressure, nozzle geometric area ratio, and nozzle axial station has been performed. Flow diagnostics used to examine expansion tunnel flow characteristics were time histories and profiles of pitot pressure and axial component of flow velocity. The purpose of this study was to determine experimentally what limitations might restrict predicted operational flexibility and the advantages and disadvantages of this mode of operation as compared to the expansion tube. Results are presented which demonstrate the expansion tunnel offers several advantages over the expansion tube, but the severity of the disadvantages of the tunnel makes the expansion tube mode of operation the more desirable for performing hypersonic-hypervelocity aerothermodynamic studies of proposed entry configurations.

Miller, C. G.↗

Performance Evaluation of the NASA/KSC Transmission System

NASA-KSC currently uses three bridged 100-Mbps FDDI segments as its backbone for data traffic. The FDDI Transmission System (FTXS) connects the KSC industrial area, KSC launch complex 39 area, and the Cape Canaveral Air Force Station. The report presents a performance modeling study of the FTXS and the proposed ATM Transmission System (ATXS). The focus of the study is on performance of MPEG video transmission on these networks. Commercial modeling tools - the CACI Predictor and Comnet tools - were used. In addition, custom software tools were developed to characterize conversation pairs in Sniffer trace (capture) files to use as input to these tools. A baseline study of both non-launch and launch day data traffic on the FTXS is presented. MPEG-1 and MPEG-2 video traffic was characterized and the shaping of it evaluated. It is shown that the characteristics of a video stream has a direct effect on its performance in a network. It is also shown that shaping of video streams is necessary to prevent overflow losses and resulting poor video quality. The developed models can be used to predict when the existing FTXS will 'run out of room' and for optimizing the parameters of ATM links used for transmission of MPEG video. Future work with these models can provide useful input and validation to set-top box projects within the Advanced Networks Development group in NASA-KSC Development Engineering.

Christensen, Kenneth J.↗

On Characterization of Laminar to Turbulent Transitional Flow in the Truncated IHF Semi-Elliptical Nozzle

This paper reports computational analysis and experimental data to characterize the laminar to turbulent flow transition in a high-enthalpy panel test facility at NASA Ames Research Center. The recently developed facility configuration uses a truncated version of an existing semi-elliptical nozzle in the 60-MW Interaction Heating Facility, and it provides testing capability for panel test articles as large as 43.2 cm x 43.2 cm (17 in x 17 in). A water-cooled calibration plate, which is attached to the semi-elliptical nozzle bottom surface and instrumented with twenty Gardon-gage heat flux calorimeters and twelve pressure gages, is used to characterize the convective heating environment over the panel test articles. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, and the flowfields over panel test articles, and comparisons with the measured test data. Both laminar and turbulent simulations are performed. Constant current studies are performed: the measured data are grouped at the same arc current levels with varying mass flow rates, and they are compared with corresponding computations. For all currents studied, these studies indicate that the semi-elliptical nozzle flow is transitional at relatively higher mass flow rates within the facility operating envelope.

Arc-jets↗