Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optimal accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Collimator design for a dedicated molecular breast imaging-guided biopsy system: Proof-of-concept

Purpose: Molecular breast imaging (MBI) is a dedicated nuclear medicine breast imaging modality that employs dual-head cadmium zinc telluride (CZT) gamma cameras to functionally detect breast cancer. MBI has been shown to detect breast cancers otherwise occult on mammography and ultrasound. Currently, a MBI-guided biopsy system does not exist to biopsy such lesions. Our objective was to consider the utility of a novel conical slant-hole (CSH) collimator for rapid (<1 min) and accurate monitoring of lesion position to serve as part of a MBI-guided biopsy system. Methods: An initial CSH collimator design was derived from the dimensions of a parallel-hole collimator optimized for MBI performed with dual-head CZT gamma cameras. The parameters of the CSH collimator included the collimator height, cone slant angle, thickness of septa and cones of the collimator, and the annular areas exposed at the base of the cones. These parameters were varied within the geometric constraints of the MBI system to create several potential CSH collimator designs. The CSH collimator designs were evaluated using Monte Carlo simulations. The model included a breast compressed to a thickness of 6 cm with a 1-cm diameter lesion located 3 cm from the collimator face. The number of particles simulated was chosen to represent the count density of a low-dose, screening MBI study acquired with the parallel-hole collimator for 10 min after a {approx}150 MBq (4 mCi) injection of Tc-99m sestamibi. The same number of particles was used for the CSH collimator simulations. In the resulting simulated images, the count sensitivity, spatial resolution, and accuracy of the lesion depth determined from the lesion profile width were evaluated. Results: The CSH collimator design with default parameters derived from the optimal parallel-hole collimator provided 1-min images with error in the lesion depth estimation of 1.1 {+-} 0.7 mm and over 21 times the lesion count sensitivity relative to 1-min images acquired with the current parallel-hole collimator. Sensitivity was increased via more vertical cone slant angles, larger annular areas, thinner cone walls, shorter cone heights, and thinner radiating septa. Full width at half maximum trended in the opposite direction as sensitivity for all parameters. There was less error in the depth estimates for less vertical slant angles, smaller annular areas, thinner cone walls, cone heights near 1 cm, and generally thinner radiating septa. Conclusions: A Monte Carlo model was used to demonstrate the feasibility of a CSH collimator design for rapid biopsy application in molecular breast imaging. Specifically, lesion depth of a 1-cm diameter lesion positioned in the center of a typical breast can be estimated with error of less than 2 mm using circumferential count profiles of images acquired in 1 min.

60 APPLIED LIFE SCIENCES↗

Validation of Non-Invasive Waste Assay System (Gamma Box Counter) Performance at AECL Whiteshell Laboratories - 13136

Low-level radioactive waste (LLW) in solid form, resulting from decommissioning and operations activities at AECL's Whiteshell Laboratories (WL), is packaged in B-25 and B-1000 standard waste containers and characterized before it is shipped to an on-site interim storage facility, pending AECL decisions on long term management of its LLW. Assay of the waste packages before shipment contributes to an inventory of the interim storage facility and provides data to support acceptance at a future repository. A key characterization step is a gamma spectrometric measurement carried out under standard conditions using an automated, multi-detector Waste Assay System (WAS), purchased from Antech Corporation. A combination of ORTEC gamma acquisition software and custom software is used in this system to incorporate multiple measurements from two collimated high-resolution detectors. The software corrects the intensities of the gamma spectral lines for geometry and attenuation, and generates a table of calculated activities or limits of detection for a user-defined list of radioisotopes that may potentially be present. Validation of WAS performance was a prerequisite to routine operation. Documentation of the validation process provides assurance of the quality of the results produced, which may be needed one or two decades after they were generated. Aspects of the validation included setting up a quality control routine, measurements of standard point sources in reproducible positions, study of the gamma background, optimization of user-selectable software parameters, investigation of the effect of non-uniform distribution of materials and radionuclides, and comparison of results with measurements made using other gamma detector systems designed to assay bulk materials. The following key components of the validation process have been established. A daily quality control routine has been instituted, to verify stability of the gamma detector operation and the background levels. A test box containing plywood (specific gravity 0.5) with holes for reproducible positioning of known point sources has been constructed and used in several configurations. Gamma spectra have been processed multiple times with user-adjustable parameters set to a variety of values to gain agreement on the most appropriate settings. A similar optimization process was followed with the custom software provided by the instrument manufacturer to reach agreement on the most stable settings for reliable results. Measurements made with the Canberra In-Situ Object Counting System (ISOCS) instrument were compared with the WAS results as part of an estimate of instrument precision and accuracy. The validation report will conclude with recommendations for the configuration, appropriate use and limitations of the Waste Assay System. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nonlinear gyrokinetic predictions of SPARC burning plasma profiles enabled by surrogate modeling

Multi-channel, nonlinear predictions of core temperature and density profiles are performed for the SPARC tokamak accounting for both kinetic neoclassical and fully nonlinear gyro-kinetic turbulent fluxes. A series of flux-tube, nonlinear, electromagnetic simulations using the CGYRO code with six gyrokinetic species are coupled to a nonlinear optimizer using Gaussian process regression techniques. The simultaneous evolution of energy sources, including alpha heat, radiation, and energy exchange, coupled with these high fidelity models and techniques, leads to a converged solution in electron temperature, ion temperature and electron density channels with a minimal number of expensive gyrokinetic simulations without compromising accuracy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-453: Image-Guided Patient-Specific Quality Assurance for Multi-Target Single Isocenter Intracranial VMAT Radiosurgery

Purpose: To demonstrate a patient specific, image-guided quality assurance method that tests both dosimetric and geometric accuracy for single-isocenter multiple-target VMAT radiosurgery (SIMT-VMAT-SRS) Method: We used a new film type, EBT-XD (optimal range 0.4–40Gy), and an in-house PMMA phantom having a coronal plane for film and a 0.125 cm3 ionization chamber (IC). The phantom contained fiducial features for kV image guided setup and for accurate film marking. Five patient plans with multiple targets sizes ranging from 3 to 21mm in diameter and prescribed doses from 14 to 18 Gy were selected. Two verification plans were generated for each case with the film plane passing through the center of the largest and smallest targets. For the four largest targets we obtained an IC measurement. For each case, a calibration film was irradiated using a custom designed step pattern. The films were scanned using a flatbed color scanner and converted to dose using the calibration film and the three channel calibration method. Image registration was performed between film and treatment planning system calculations to evaluate the geometric accuracy. Results: The mean registration vector had an average magnitude of 0.47 mm (range from 0.13mm to 0.64 mm). For the four largest targets, the mean ratio of the IC and film measurement to expected dose was 0.990 (range 0.968 to 1.009) and 1.032 (1.021 to 1.046), respectively. The fraction of pixels having gamma index < 1 for criteria of 3%/3mm, 3%/2mm, 3%/1mm was 98.8%, 97.5% and 87.2% before geometric registration and 99.1%, 98.3% and 94.8% after registration. Conclusion: We have demonstrated an image-guided QA method can assess both geometric and dosimetric accuracy. The phantom was positioned with sub-millimeter accuracy. Absolute film dosimetry using EBT-XD film was sufficiently accurate for assessment of dose to multi-targets too small for IC measurement in SRS VMAT plans.

60 APPLIED LIFE SCIENCES↗

Comparing Numerical Models of the TALOS Wave Energy Converter

In this study, we present the development of a numerical model of the TALOS Wave Energy Converter (WEC) in WEC-Sim and compare it with existing numerical in-house models from Lancaster and results from DNV's Sesam code. The objective of this work is to validate the performance of the TALOS WEC using WEC-Sim and compare the results with those obtained from other numerical models. The TALOS WEC is a promising technology for the generation of clean, renewable energy from ocean waves. The development of a reliable numerical model for the TALOS WEC is crucial for its design and optimization. To achieve this, we have implemented the TALOS WEC in WEC-Sim and compared the results to in-house models from Lancaster and to results from DNV's Sesam code. Our results show good agreement with the results from Lancaster and DNV, demonstrating the accuracy and reliability of the numerical model developed in WEC-Sim. This work advances the field of wave energy conversion by providing a verified numerical model of the TALOS WEC, which can be used for further optimization and design studies.

CFD↗

Real-time tumor tracking: Automatic compensation of target motion using the Siemens 160 MLC

Purpose: Advanced high quality radiation therapy techniques such as IMRT require an accurate delivery of precisely modulated radiation fields to the target volume. Interfractional and intrafractional motion of the patient's anatomy, however, may considerably deteriorate the accuracy of the delivered dose to the planned dose distributions. In order to compensate for these potential errors, a dynamic real-time capable MLC control system was designed. Methods: The newly developed adaptive MLC control system contains specialized algorithms which are capable of continuous optimization and correction of the aperture of the MLC according to the motion of the target volume during the dose delivery. The algorithms calculate the new leaf positions based on target information provided online to the system. The algorithms were implemented in a dynamic target tracking control system designed for a Siemens 160 MLC. To assess the quality of the new target tracking system in terms of dosimetric accuracy, experiments with various types of motion patterns using different phantom setups were performed. The phantoms were equipped with radiochromic films placed between solid water slabs. Dosimetric results of exemplary deliveries to moving targets with and without dynamic MLC tracking applied were compared in terms of the gamma criterion to the reference dose delivered to a static phantom. Results: Our measurements indicated that dose errors for clinically relevant two-dimensional target motion can be compensated by the new control system during the dose delivery of open fields. For a clinical IMRT dose distribution, the gamma success rate was increased from 19% to 77% using the new tracking system. Similar improvements were achieved for the delivery of a complete IMRT treatment fraction to a moving lung phantom. However, dosimetric accuracy was limited by the system's latency of 400 ms and the finite leaf width of 5 mm in the isocenter plane. Conclusions: Different experimental setups representing different target tracking scenarios proved that the tracking concept, the new algorithms and the dynamic control system make it possible to effectively compensate for dose errors due to target motion in real-time. These early results indicate that the method is suited to increasing the accuracy and the quality of the treatment delivery for the irradiation of moving tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of a Multiphase Adjoint Capability in OpenFOAM

Thermal hydraulic predictions of flow regimes within nuclear reactor cores require significant computational resources and accuracy to ensure that the core design does not violate the thermal limits of materials. Multiphase computational fluid dynamics (CFD) has become a valuable computational capability for predicting flow characteristics as they relate to applications such as nuclear reactor safety and mixing phenomena around spacer grids within fuel assemblies. Multiphase CFD requires closure relationships for both the effects of turbulence as well as the transfer of mass, momentum, and energy between phases. Understanding the sensitivity of the parameters used in closure relationships is important for improving accuracy, but performing rigorous sensitivity analysis is computationally expensive. Adjoint mathematics have been utilized for reactor physics and fluid dynamics applications with respect to verification, sensitivity analysis, adaptive mesh refinement, and optimization. The usage of adjoint methods to predict the sensitivities of a variety of closure relationship parameters within a given problem has been shown to return sensitivity responses with significantly fewer computations than normal 'large-scale' methods. As the complexity of multiphase CFD methods increases, the demand for accurate verification tools and improvements in computational efficiency also increases, making the development of adjoint capabilities an attractive option. Closure relationships that describe interphase momentum physics in multiphase CFD modelling rely heavily on prescribed constants determined from experimental data. Due to the computational efficiency of an adjoint approach, the time to derive these closure relationships could be dramatically reduced, and data assimilation techniques could be used to return probability density functions of closure models derived using experimental data. This work develops a multiphase adjoint capability for the Eulerian-Eulerian two field, two phase equations. Specifically, the adjoint capability has been developed for the sub-cooled nucleate boiling solver boilEulerFoam developed by Dr. Nam Dinh of NC State University within the open-source CFD library OpenFOAM.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Accelerating Simulation for High-Fidelity PV Inverter System Reliability Assessment with High-Performance Computing

The overall cost of photovoltaic (PV) systems has shown a downward trend during the last decade; however, PV inverter failures account for the highest cost of operation and maintenance. To address this, reliability tools with powerful computation and better accuracy are required for the lifetime prediction and degradation evaluation of PV inverters. This paper proposes an event-driven parallel computing-based simulator. The proposed simulator applies high-performance computing techniques and other accessory optimization techniques-including cluster merging, adaptive model updates, and steady-state identification-to make reliability assessments for PV inverters under given input mission profiles and operating conditions with high efficiency and high fidelity. The main idea of the simulator and its workflow are introduced. Then, a demo PV inverter system simulator is implemented, and the speedup of the total simulations of the switching model reaches 123.03 times.

high-performance computing↗

High-Accuracy Tidal Flat Digital Elevation Model Construction Using TanDEM-X Science Phase Data

This study explored the feasibility of using TanDEM-X (TDX) interferometric observations of tidal flats for digital elevation model (DEM) construction. Our goal was to generate high-precision DEMs in tidal flat areas, because accurate intertidal zone data are essential for monitoring coastal environment sand erosion processes. To monitor dynamic coastal changes caused by waves, currents, and tides, very accurate DEMs with high spatial resolution are required. The bi- and monostatic modes of the TDX interferometer employed during the TDX science phase provided a great opportunity for highly accurate intertidal DEM construction using radar interferometry with no time lag (bistatic mode) or an approximately 10-s temporal baseline (monostatic mode) between the master and slave synthetic aperture radar image acquisitions. In this study, DEM construction in tidal flat areas was first optimized based on the TDX system parameters used in various TDX modes. We successfully generated intertidal zone DEMs with 57-m spatial resolutions and interferometric height accuracies better than 0.15 m for three representative tidal flats on the west coast of the Korean Peninsula. Finally, we validated these TDX DEMs against real-time kinematic-GPS measurements acquired in two tidal flat areas; the correlation coefficient was 0.97 with a root mean square error of 0.20 m.

Lee, Seung-Kuk↗

Efficient Implementation of an Optimal Interpolator for Large Spatial Data Sets

Interpolating scattered data points is a problem of wide ranging interest. A number of approaches for interpolation have been proposed both from theoretical domains such as computational geometry and in applications' fields such as geostatistics. Our motivation arises from geological and mining applications. In many instances data can be costly to compute and are available only at nonuniformly scattered positions. Because of the high cost of collecting measurements, high accuracy is required in the interpolants. One of the most popular interpolation methods in this field is called ordinary kriging. It is popular because it is a best linear unbiased estimator. The price for its statistical optimality is that the estimator is computationally very expensive. This is because the value of each interpolant is given by the solution of a large dense linear system. In practice, kriging problems have been solved approximately by restricting the domain to a small local neighborhood of points that lie near the query point. Determining the proper size for this neighborhood is a solved by ad hoc methods, and it has been shown that this approach leads to undesirable discontinuities in the interpolant. Recently a more principled approach to approximating kriging has been proposed based on a technique called covariance tapering. This process achieves its efficiency by replacing the large dense kriging system with a much sparser linear system. This technique has been applied to a restriction of our problem, called simple kriging, which is not unbiased for general data sets. In this paper we generalize these results by showing how to apply covariance tapering to the more general problem of ordinary kriging. Through experimentation we demonstrate the space and time efficiency and accuracy of approximating ordinary kriging through the use of covariance tapering combined with iterative methods for solving large sparse systems. We demonstrate our approach on large data sizes arising both from synthetic sources and from real applications.

Memarsadeghi, Nargess↗

Aerodynamic Shape Optimization Benchmarks with Error Control and Automatic Parameterization

Results are presented for four optimization benchmark problems posed by the AIAA Aerodynamic Design Optimization Discussion Group. The benchmarks are intended to exercise optimization frameworks on representative airfoil and wing design problems. All problems involve drag minimization subject to geometric and aerodynamic constraints. Our design approach involves two forms of adaptation. First, the shape parameterization is gradually and automatically enriched from an initially coarse search space. Second, adjoint solutions are used to drive adaptive mesh refinement to control discretization error. The error threshold is tailored so that the nest meshes, with the greatest accuracy, are used only when nearing the optimum. On the inviscid airfoil design problem, while reducing the drag by a factor of 10, we show how the combination of progressive parameterization and tiered discretization error control can dramatically accelerate the optimization. On the viscous airfoil design problem, we use inviscid analysis-driven optimization to reduce the total drag by a factor of two. Next, we improve the span efficiency factor of a wing by performing twist optimization. Finally, we optimize the Common Research Model wing, managing to hold drag roughly fixed, while targeting an initially-violated pitching moment constraint. Our approach aims to introduce greater complexity and accuracy only when necessary to improve the design, and also support a greater degree of automation.

Anderson, George R.↗

Precision Magnet Measurements for X-Band Accelerator Quadrupole Triplets

An X-band test station is being developed at LLNL to investigate accelerator optimization for future upgrades to mono-energetic gamma-ray (MEGa-Ray) technology at LLNL. Beamline magnets will include an emittance compensation solenoid, windowpane steering dipoles, and quadrupole magnets. Demanding tolerances have been placed on the alignment of these magnets, which directly affects the electron bunch beam quality. A magnet mapping system has been established at LLNL in order to ensure the delivered magnets match their field specification, and the mountings are aligned and capable of reaching the specified alignment tolerances. The magnet measurement system will be described which uses a 3-axis Lakeshore gauss probe mounted on a 3-axis translation stage. Alignment accuracy and precision will be discussed, as well as centering measurements and analysis. The dependence on data analysis over direct multi-pole measurement allows a significant improvement in useful alignment information. Detailed analysis of measurements on the beamline quadrupoles will be discussed, including multi-pole content both from alignment of the magnets, and the intrinsic level of multi-pole magnetic field.

42 ENGINEERING↗

Sampling Size Optimization for Bioburden Density Estimation in Planetary Protection

Planetary protection (PP) is a discipline that focuses on minimizing the biological contamination of spacecraft to ensure compliance with international policy. Precise estimation of bioburden - the total number of microbes in or on spacecraft hardware – and the bioburden density are of utmost importance for PP. Such estimation is the way concordance with requirements is demonstrated, and it is critical for quantifying the potential risk of inadvertently contaminating other planetary bodies. Although a suite of molecular techniques have been used to thoroughly characterize and profile the microbiome of various cleanroom environments and spacecraft, the gold standard remains the physical enumeration of microbes via culturing of samples directly taken from spacecraft and associated surfaces. However, due to technical, budgetary, and programmatic constraints, only a manageable portion (around 10%) of the entire spacecraft surface is directly sampled with cotton swabs or wipes. To generate the bioburden current best estimate (CBE) for components not directly verifiable, the accepted approach is to apply a NASA-defined bioburden estimate based on the components’ manufacturing or assembly environment. This approach utilizes a prespecified bioburden density estimation that applies a maximum value across the total surface area of the specified component. For hardware components that underwent similar assembly processes, an implied bioburden is adopted for all components, based on a direct verification of a representative component within the same lot. Once all components have a CBE, the bioburden estimates are generated. In previous publication [ 1], we have shown that statistical risks quantifying the accuracy of the estimates for sampled, prespecified, and implied components can be derived and ranked. For mean squared error (MSE) function, the risks are available analytically and hence a cost function can be obtained to optimize the risks with respect to the sampling area and sampling cost. Since the sampling area and sampling cost are two complimentary variables, their sum will have a well-defined minimum. This paper presents the multivariate optimization of the integrated risk of an empirical Bayes estimator to determine the optimal sampling schedule for a given number of components. It is assumed that given a number of components, N, the bioburden density for each component can either be sampled, implied, or prespecified. The multivariate optimization searches through different options to sample, imply or prespecify the bioburden density for a component, and account for the component’s surface area and cost of sampling. The idea of the optimization is based on the observation that the statistical risk of using an estimator is a monotonically decreasing function of the sampled area. The larger the sampled area, the lower the risk of using the estimator as the estimator becomes more and more accurate as the sampling area increases. On the other hand, the cost of sampling is monotonically increasing as the sampled surface grows. This makes the risk and total cost of sampling complimentary variables which can be counterbalanced to achieve an optimal overall value with respect to the sampled surface. In this paper, the integrated risk has been used to quantify the accuracy of the estimator. This risk has been selected because it depends on neither the true value of the parameter nor on the collected data. The cost of each sample was also available to obtain the total cost of sampling of N components. The paper will present the results based on computer-simulated data as well as the data collected during the InSight mission. The computer-simulated data have N components with randomly generated total areas and each component assigned to one of the three categories according to the method of estimating of bioburden density: sampled, implied, or prespecified. The cost of sampling is also available. The cost of sampling is estimated based on a cost model provided by the planetary protection group at JPL. For this paper, the overall cost was assumed to be a linear function of exposure. The optimization process finds the allocation of the components to the three categories that minimizes the tradeoff between integrated risk and total cost. For the InSight data, a set of components is selected representing all three categories, and optimization is performed to determine if the performed allocation was optimal or if a better allocation could have been obtained. To the best of our knowledge, this work is the first attempt not only perform an accurate estimation of bioburden density but also do it in an optimal way.

97 - MATHEMATICS AND COMPUTING↗

Note: Optical and electronic design of an amplitude-modulated continuous-wave laser scanner for high-accuracy distance measurement

To utilize a time-of-flight-based laser scanner as a distance measurement sensor, the measurable distance and accuracy are the most important performance parameters to consider. For these purposes, the optical system and electronic signal processing of the laser scanner should be optimally designed in order to reduce a distance error caused by the optical crosstalk and wide dynamic range input. Optical system design for removing optical crosstalk problem is proposed in this work. Intensity control is also considered to solve the problem of a phase-shift variation in the signal processing circuit caused by object reflectivity. The experimental results for optical system and signal processing design are performed using 3D measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resilience Evaluation and Enhancement for Island City Integrated Energy Systems

Extreme natural hazards, such as hurricanes or earthquakes, have a high probability of threatening energy supply security and causing high-order contingencies to island city-integrated energy systems (IC-IESs). To better evaluate and enhance resilience, a novel approach is proposed in this work for IC-IESs. The resilience of an IC-IES is analyzed from both the system level and the component level. At the system level, the impacts of extreme natural disasters are quantified. At the component level, the importance of individual components is analyzed through pre-failure and post-failure indices. The pre-failure index identifies the system’s weak links before an energy interruption, and the post-failure index determines the optimal repair strategy to restore the service. The proposed indices are solved by the impact increment method (IIM), which significantly improves computational efficiency without much affecting result accuracy. Numerical simulation studies are conducted on the modified Barry Island IES and IES E123-G48-H32 test systems. Furthermore, the results validate the effectiveness of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Integrated Framework for Memory-Centric Analysis: From Trace Collection to Co-Design

The memory wall phenomenon—where advances in processor performance significantly outpace those in memory subsystems—poses a fundamental challenge for contemporary computing systems. In memory-bound applications, memory subsystem behavior dominates performance, yet existing analysis approaches present significant limitations: detailed microarchitectural simulators require days to weeks to simulate modest workloads; hardware performance counters provide only aggregate statistics that obscure temporal and spatial access patterns; and scaled simulation approaches face challenges in capturing certain behaviors that emerge at larger scales. These limitations reflect a processor-centric design philosophy increasingly misaligned with memory-bound workloads where detailed understanding of memory access patterns, cache hierarchy interactions, and contention is critical for effective optimization. This paper presents an integrated framework for memory-centric analysis that enables effective hardware-software co-design. We describe practical trace collection techniques, including hardware-assisted processor tracing with minimal overhead and portable software-based instrumentation with statistical sampling. We present multi-perspective analysis methods that examine memory behavior from temporal, sequential, spatial, and relational viewpoints, revealing distinct optimization opportunities invisible in aggregate metrics. We detail an architectural modeling framework that uses sampled traces with temporal interpolation and confidence-based filtering to evaluate cache and memory configurations. Evaluation on representative benchmarks demonstrates that this framework achieves practical accuracy (L2 cache errors of 2.64\%, confidence-filtered L3 errors of 9.92\%, bandwidth errors of 7.33\%) while providing substantial speedup (26.8×) over cycle-accurate simulation, enabling rapid design space exploration. We demonstrate how this integrated framework enables systematic identification of both hardware optimizations (memory controller tuning, bank partitioning, NUMA configuration) and software optimizations (data layout restructuring, prefetching strategies, memory-aware scheduling). Through this comprehensive treatment of the memory-centric analysis pipeline—from trace collection through architectural modeling to co-design application—we provide researchers and practitioners with practical techniques for addressing memory bottlenecks in contemporary computing systems.

Gajaria, Dhruv Mayur↗

SU-E-T-793: Validation of COMPASS 3D Dosimetry as Pre Treatment Verification with Commercial TPS Algorithms

Purpose: The purpose of this study was to validate the advent of COMPASS 3D dosimetry as a routine pre treatment verification tool with commercially available CMS Monaco and Oncentra Masterplan planning system. Methods: Twenty esophagus patients were selected for this study. All these patients underwent radical VMAT treatment in Elekta Linac and plans were generated in Monaco v5.0 with MonteCarlo(MC) dose calculation algorithm. COMPASS 3D dosimetry comprises an advanced dose calculation algorithm of collapsed cone convolution(CCC). To validate CCC algorithm in COMPASS, The DICOM RT Plans generated using Monaco MC algorithm were transferred to Oncentra Masterplan v4.3 TPS. Only final dose calculations were performed using CCC algorithm with out optimization in Masterplan planning system. It is proven that MC algorithm is an accurate algorithm and obvious that there will be a difference with MC and CCC algorithms. Hence CCC in COMPASS should be validated with other commercially available CCC algorithm. To use the CCC as pretreatment verification tool with reference to MC generated treatment plans, CCC in OMP and CCC in COMPASS were validated using dose volume based indices such as D98, D95 for target volumes and OAR doses. Results: The point doses for open beams were observed <1% with reference to Monaco MC algorithms. Comparisons of CCC(OMP) Vs CCC(COMPASS) showed a mean difference of 1.82%±1.12SD and 1.65%±0.67SD for D98 and D95 respectively for Target coverage. Maximum point dose of −2.15%±0.60SD difference was observed in target volume. The mean lung dose of −2.68%±1.67SD was noticed between OMP and COMPASS. The maximum point doses for spinal cord were −1.82%±0.287SD. Conclusion: In this study, the accuracy of CCC algorithm in COMPASS 3D dosimetry was validated by compared with CCC algorithm in OMP TPS. Dose calculation in COMPASS is feasible within < 2% in comparison with commercially available TPS algorithms.

60 APPLIED LIFE SCIENCES↗

Ingrained: An Automated Framework for Fusing Atomic-Scale Image Simulations into Experiments

To fully leverage the power of image simulation to corroborate and explain patterns and structures in atomic resolution microscopy, an initial correspondence between the simulation and experimental image must be established at the outset of further high accuracy simulations or calculations. Furthermore, if simulation is to be used in context of highly automated processes or high-throughput optimization, the process of finding this correspondence itself must be automated. In this work, "ingrained," an open-source automation framework which solves for this correspondence and fuses atomic resolution image simulations into the experimental images to which they correspond, is introduced. Here, the overall "ingrained" workflow, focusing on its application to interface structure approximations, and the development of an experimentally rationalized forward model for scanning tunneling microscopy simulation are described.

36 MATERIALS SCIENCE↗