Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loading models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Design Load Basis Guidance for Distributed Wind Turbines

Aeroelastic modeling (AM) is the primary methodology for structural and performance assessment of any wind turbine. Nonetheless, the use of AM in the distributed wind (DW) industry sector is limited due to several challenges (Damiani, Davis, & Summerville, 2022). One of these challenges lies in the perceived complexity of generating a proper set of numerical simulations to extract and process the key outputs for component design and verification, and, ultimately, achieve certification. This makes it difficult to reliably predict the structural and performance response of small wind turbines. From the investigation carried out in (Damiani & Davis, 2022), it is apparent that many stakeholders in this sector believe that a comprehensive guide for developing a design load basis (DLB) for distributed wind turbines (DWTs) is necessary.

17 WIND ENERGY↗

Uncertainty propagation through an aeroelastic wind turbine model using polynomial surrogates

Polynomial surrogates are used to characterize the energy production and lifetime equivalent fatigue loads for different components of the DTU 10 MW reference wind turbine under realistic atmospheric conditions. The variability caused by different turbulent inflow fields are captured by creating independent surrogates for the mean and standard deviation of each output with respect to the inflow realizations. A global sensitivity analysis shows that the turbulent inflow realization has a bigger impact on the total distribution of equivalent fatigue loads than the shear coefficient or yaw miss-alignment. The methodology presented extends the deterministic power and thrust coefficient curves to uncertainty models and adds new variables like damage equivalent fatigue loads in different components of the turbine. These surrogate models can then be implemented inside other work-flows such as: estimation of the uncertainty in annual energy production due to wind resource variability and/or robust wind power plant layout optimization. It can be concluded that it is possible to capture the global behavior of a modern wind turbine and its uncertainty under realistic inflow conditions using polynomial response surfaces. In conclusion, the surrogates are a way to obtain power and load estimation under site specific characteristics without sharing the proprietary aeroelastic design.

17 WIND ENERGY↗

A directional microcrack damage theory for brittle solids based on continuous hyperplasticity

We present a novel microcrack-damage theory for brittle solids under compression. Instead of using internal variables like zeroth, second or fourth rank damage tensors, the state of material damage is represented by an internal function that encapsulates the information of direction, density and size of microcracks. Just like other internal variables, the evolution of this state function must obey the second law of thermodynamics for arbitrary loading paths. This is done by casting the model in the framework of continuous hyperplasticity and enforcing a non-negative dissipation rate functional. The proposed framework offers predictions on the continuous evolution of microcrack density and the induced material anisotropy along with the macroscopic stress-strain curves. The use of continuous damage function grants the model significantly enhanced resolution in characterizing the direction-dependent response of cracked solids compared to classical models that are based on damage tensors. Two scenarios are considered in developing the theory, one assumes frictionless cracks and the other incorporates friction between crack surfaces. The results highlight that inelasticity, pressure dependence, and loading-unloading hysteresis exhibited by brittle solids are natural consequences of frictional microcracks. The proposed theory offers a generic and versatile framework to upscale micromechanical processes operating at individual crack scale to explain the macroscopic behavior of cracked solids.

Materials Science↗

A dual-phase microstructural approach to damage and fracture of Ti 3 SiC 2 /SiC joints

We investigate the microcracking mechanisms responsible for Ti 3 SiC 2 /SiC joint damage observed at the macroscopic scale after neutron irradiation experiments in detail. A dual-phase microstructural approach to damage and fracture of Ti 3 SiC 2 /SiC joints is developed that uses a finely discretized two-phase domain based on a digital image of an actual microstructure involving embedded Ti 3 SiC 2 and SiC phases. The behaviors of SiC and Ti 3 SiC 2 in the domain are described by the continuum damage mechanics (CDM) model reported in Nguyen et al., J. Nucl. Mater., 2017, 495:504–515. This CDM model describes microcracking damage in brittle ceramics caused by thermomechanical loading and irradiation-induced swelling. The dual-phase microstructural model is applied to predict the microcracking mechanisms occurring in a typical Ti 3 SiC 2 /SiC joint subjected to heating to 800 °C followed by irradiation-induced swelling at this temperature and cooling to room temperature after the applied swelling has reached the maximum swelling levels observed in the experiments for SiC and Ti 3 SiC 2 . The model predicts minor damage of the joint after heating but significant microcracking in the SiC phase and along the boundaries between SiC and Ti 3 SiC 2 as well as along the bonding joint during irradiation-induced swelling and cooling to room temperature. Our predictions qualitatively agree with the limited experimental observations of joint damage at this irradiation temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Indirect Tool Condition Monitoring Using Ensemble Machine Learning Techniques

Abstract Tool condition monitoring (TCM) has become a research area of interest due to its potential to significantly reduce manufacturing costs while increasing process visibility and efficiency. Machine learning (ML) is one analysis technique which has demonstrated advantages for TCM applications. However, the commonly studied individual ML models lack generalizability to new machining and environmental conditions, as well as robustness to the unbalanced datasets which are common in TCM. Ensemble ML models have demonstrated superior performance in other fields, but have only begun to be evaluated for TCM. As a result, it is not well understood how their TCM performance compares to that of individual models, or how homogeneous and heterogeneous ensemble models’ performances compare to one another. To fill in these research gaps, milling experiments were conducted using various cutting conditions, and the model groups were compared across several performance metrics. Statistical t-tests were also used to evaluate the significance of model performance differences. Through the analysis of four individual ML models and five ensemble models, all based on the processes’ sound, spindle power, and axial load signals, it was found that on average, the ensemble models performed better than the individual models, and that the homogeneous ensembles outperformed the heterogeneous ensembles.

Engineering↗

A novel large-scale EV charging scheduling algorithm considering V2G and reactive power management based on ADMM

Electric vehicle aggregators (EVAs) that utilize vehicle-to-grid (V2G) technologies can function as both controllable loads and virtual power plants, providing key energy management services to the distribution system operator (DSO). EVAs can also balance the grid’s reactive power as a virtual static VAR compensator (SVC) and provide voltage stability by utilizing advanced electric vehicle (EV) chargers that are capable of four-quadrant operations to provide reactive power management. Finally, managed charging can benefit EVAs themselves by minimizing power factor penalties in their electricity bills. In this paper, we propose a novel EV charging scheduling algorithm based on a hierarchical distributed optimization framework that minimizes peak load and provides reactive power compensation for the DSO by collaboration with EVAs that manage both the active and the reactive charging and discharging power of participating EVs. Utilizing the alternative direction method of multipliers (ADMM), the proposed distributed optimization approach scales well with increased EV charging infrastructure by balancing active and reactive power while decreasing computational burden. In our proposed hierarchical approach, each EVA schedules the active and reactive EV charging and discharging power for 1) reactive power compensation in order to minimize power factor penalty and electricity cost accrued by the EVA, 2) satisfaction of each EV’s energy demand at minimal charging cost, and 3) peak shaving and load management for the DSO. When compared with an uncoordinated charging model, the efficacy of this proposed model is successfully demonstrated through a 300% decreased peak EV load for the DSO, 28% lower electricity costs for EV users, and 98.55% smaller power factor penalty, along with 17.58% lower overall electricity costs, for EVAs. The performance of our approach is validated in a case study with 50 EVs at multiple EVAs in an IEEE 13-bus test case and compared the results with uncoordinated EV charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Convex Relaxation of OPF in Multiphase Radial Networks with Wye and Delta Connections

This panel presentation focuses on multiphase radial distribution networks with wye and delta connections, and proposes a semidefinite relaxation of the AC optimal power flow (OPF) problem. Two multiphase power flow models are developed to facilitate the integration of delta-connected loads or generation resources in the OPF problem. The first model is referred to as the extended branch flow model (EBFM). The second model leverages a linear relationship between phase-to-ground power injections and delta connections that holds under a balanced voltage approximation (BVA). Based on these models, pertinent OPF problems are formulated and relaxed to semidefinite programs (SDPs). Numerical studies on IEEE test feeders show that the proposed SDP relaxations can be solved efficiently by a generic optimization solver. Numerical evidence also indicates that solving the resultant SDP under BVA is faster than under EBFM. Moreover, both SDP solutions are numerically exact with respect to voltages and branch flows. It is further shown that the SDP solution under BVA has a small optimality gap, and the BVA model is accurate in the sense that it reproduces actual system voltages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

GLIMPSE of Future Power Grid Models

Power grid is one of the critical national infrastructures with social, economics, and national security impacts. Particularly, power distribution systems represent part of the infrastructure between power distribution substations and customers such as residential, commercial, and industrial. To address various grid modernization challenges, state-of-the-art algorithms and methodologies have been developed to deploy, operate, and expand a secure and resilient power grid. At the same time, there is a need to develop capabilities to assist power grid stakeholders to quickly get insight into the design and structure of the grid. Data visualization is a key approach to comprehend and understand complex systems such as the power grid. We present GLIMPSE Grid Layout Interface for Model Preview and System Exploration), a graph-based semantic-aware application to visualize and update distribution power grid models. The GLIMPSE can be used with standard IEEE models to search and highlight power grid objects such as generators, loads, overhead lines, etc. Additionally, it supports updating attributes and model export to integrate with GridLAB-D simulations.

Cybersecurity, power grid, visualization↗

Value of storage with increased renewable penetration.

The problem statement for this project is: (1) Renewable energy portfolio standards - (a) high penetration of intermittent and variable renewable generation on the grid, (b) utilities constrained by NERC Control Performance Standards, (c) requires additional resources to match generation with load; and (2) mitigation of impacts with energy storage - at what level of renewable penetration does energy storage become an attractive value proposition. Use a simplified, yet robust dispatch model that: (a) incorporates New Mexico Balance Area load and wind generation data, (b) distributes the load among a suite of generators, (c) quantifies increased generation costs with increased penetration of intermittent and variable renewable generation - fuel, startup, shut down, ramping, standby, etc., (d) tracks and quantifies NERC pentalties and violations, and (e) quantifies storage costs. Dispatch model has been constructed and it: (a) accurately distributes a load among a suite of generators, (b) quantifies duty cycle metrics for each of the generators - cumulative energy production, ramping and non ramping duration, spinning reserves, number of start-ups, and shut down durations, etc., (c) quantifies energy exchanges - cumulative exchanges, duration, and number of exchanges, (d) tracks ACE violations.

25 ENERGY STORAGE↗

Assessment of Wind Parameter Sensitivity on Ultimate and Fatigue Wind Turbine Loads: Preprint

Wind turbines are designed using a set of simulations to ascertain the structural loads that the turbine could encounter. While mean hub-height wind speed is considered to vary, other wind parameters such as turbulence spectra, sheer, veer, spatial coherence, and component correlation are fixed or conditional values that, in reality, could have different characteristics at different sites and have a significant effect on the resulting loads. This paper therefore seeks to assess the sensitivity of different wind parameters on the resulting ultimate and fatigue loads on the turbine during normal operational conditions. Eighteen different wind parameters are screened using an Elementary Effects approach with radial points. As expected, the results show a high sensitivity of the loads to the turbulence standard deviation in the primary wind direction, but the sensitivity to wind shear is often much greater. To a lesser extent, other wind parameters that drive loads include the coherence in the primary wind direction and veer.

17 WIND ENERGY↗

Uncertainty Assessment of CFD Investigation of the Nonlinear Difference-Frequency Wave Loads on a Semisubmersible FOWT Platform

Current mid-fidelity modeling approaches for floating offshore wind turbines (FOWTs) have been found to underpredict the nonlinear, low-frequency wave excitation and the response of semisubmersible FOWTs. To examine the cause of this underprediction, the OC6 project is using computational fluid dynamics (CFD) tools to investigate the wave loads on the OC5-DeepCwind semisubmersible, with a focus on the nonlinear difference-frequency excitation. This paper focuses on assessing the uncertainty of the CFD predictions from simulations of the semisubmersible in a fixed condition under bichromatic wave loading and on establishing confidence in the results for use in improving mid-fidelity models. The uncertainty for the nonlinear wave excitation is found to be acceptable but larger than that for the wave-frequency excitation, with the spatial discretization error being the dominant contributor. Further, unwanted free waves at the difference frequency have been identified in the CFD solution. A wave-splitting and wave load-correction procedure are presented to remove the contamination from the free waves in the results. A preliminary comparison to second-order potential-flow theory shows that the CFD model predicted significantly higher difference-frequency wave excitations, especially in surge, suggesting that the CFD results can be used to better calibrate the mid-fidelity tools.

17 WIND ENERGY↗

Sierra/solid mechanics 4.22 user's guide.

Sierra/SolidMechanics (Sierra/SM) is a Lagrangian, three-dimensional code for the analysis of solids and structures. It provides capabilities for explicit dynamic and implicit quasistatic and dynamic analyses. The explicit dynamics capabilities allow for the efficient and robust solution of models subjected to large, suddenly applied loads. For implicit problems, Sierra/SM uses a multi-level iterative solver, which enables it to effectively solve problems with large deformations, nonlinear material behavior, and contact. Sierra/SM has a versatile library of continuum and structural elements, and an extensive library of material models. The code is written for parallel computing environments, and it allows for scalable solutions of very large problems for both implicit and explicit analyses. It is built on the SIERRA Framework, which allows for coupling with other SIERRA mechanics codes. This document describes the functionality and input structure for Sierra/SM.

99 GENERAL AND MISCELLANEOUS↗

Fluid temperature predictions of geothermal borefields using load estimations via state observers

Fluid temperature predictions of geothermal borefields usually involves temporal superposition of its characteristic g-function, using load aggregation schemes to reduce computational times. Assuming that the ground has linear properties, it can be modeled as a linear state space system where the states are the aggregated loads. However, the application and accuracy of these models is compromised when the borefield is already operating and its load history is not registered or there are gaps in the data. This paper assesses the performance of state observers to estimate the borefield load history and obtain accurate fluid predictions. Results show that both Time-Varying Kalman Filter (TVKF) and Moving Horizon Estimator (MHE) provide predictions with average and maximum errors below 0.1 $^\circ C$ and 1 $^\circ C$ respectively. MHE outperforms TVKF in terms of n-step ahead output predictions and load history profile at the expenses of about 5 times more computational time.

Figueroa, Iago C.↗

Improved Wind Turbine Drivetrain Reliability using a Combined Experimental, Computational, and Analytical Approach (Presentation)

Nontorque loads induced by the wind turbine rotor overhang weight and aerodynamic forces can greatly affect drivetrain loads and responses. If not addressed properly, these loads can result in a decrease in gearbox component life. This work uses analytical modeling, computational modeling, and experimental data to evaluate a unique drivetrain design that minimize the effects of nontorque loads on gearbox reliability: the Pure Torque drivetrain developed by Alstom. The drivetrain has a hub-support configuration that transmits nontorque loads directly into the tower rather than through the gearbox as in other design approaches. An analytical model of Alstom's Pure Torque drivetrain provides insight into the relationships among turbine component weights, aerodynamic forces, and the resulting drivetrain loads. Main shaft bending loads are orders of magnitude lower than the rated torque and are hardly affected by wind speed and turbine operations.

17 WIND ENERGY↗

Stochastic Continuous-time Flexibility Scheduling and Pricing in Wholesale Electricity Markets

Large-scale integration of intermittent renewable energy sources (RES) is calling for additional flexibility resources as well as more advanced modeling and optimization techniques to account for the increasing uncertainty and variability in power systems operation. As the RES integration gains momentum, the magnitude and frequency of their variations increase, which may trigger ramping scarcity events in real-time power systems operation. This necessitates revisiting the present definition of power systems flexibility and reserve services to reflect their robustness and adequacy towards sub-interval variations of the load and RES, as well as adjusting the operation models to accommodate the new reserve services. This project took a fundamental approach and aimed at developing continuous-time scheduling and pricing model that accurately models the continuous-time variations of load and RES and efficiently deploys the ramping capability of flexible resources to compensate the sources of variability and uncertainty in the market. In this regard, this project pursued the following goals: Developing stochastic multi-fidelity continuous-time optimization models for scheduling of energy storage (ES) systems and flexible loads in wholesale energy markets; Developing the theory and practices of continuous-time locational marginal pricing for valuating energy storage systems and flexible loads in wholesale energy markets; Developing function space solution approach to convert the proposed stochastic multi-fidelity continuous-time optimization models into tractable mixed-integer linear optimization models; and Defining flexibility reserve as a new type of reserve in markets that would enable ultimate participation of energy storage devices in provision of services to compensate the variability and uncertainty of RES in electricity markets. This project successfully completed all five major tasks defined in the SOPO, and produced 8 high-impact journal papers, 6 conference papers, 3 published U.S. patents, and one web-based software for continuous-time operation optimization of power systems. The application of the proposed flexibility reserve and the stochastic multi-fidelity continuous-time operation scheduling models would modify the forward commitment and schedule of generating units, ES devices and flexible loads, and would line up the resources in such a way that the composition of available resources is better prepared to respond to the sub-hourly variations of the load and renewable resources in real-time operation. Therefore, this project paves the way to sustainable, reliable, and economic integration of renewable energy resources in power system, supporting the progress towards reaching the national targets on energy independence. Even if the proposed models offers a radically different point of view as compared to existing models, it does not alter fundamentally the architecture of power systems operations, nor the complexity of the scheduling problem, so the integration of this project in power systems is extremely practical.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power control system modification and simulation of CPR1000 - 181

Due to development of electric power system, the proportion of nuclear power and its needs for load follow operation have become large. Then there would be higher requirements to the power control ability of the nuclear power system. The axial power distribution may change a lot in the operation process and be affected by many factors. In particular, as the power change is performed within a load follow maneuver, several modifications occur in the core from a neutronic view point: the fuel and moderator temperature change, the xenon concentration and distribution are modified, the power distribution skewed axially, etc. These changes need to be adequately counterbalanced to keep both the core critical and the power distribution acceptable. The traditional approach in pressurized water reactors (PWRs) is compensating for the reactivity change due to the power variation by adjusting the soluble boron concentration and moving a limited number of control banks. However, dilution/boronation strategy becomes expensive for short time changes and leads to large volume of liquid effluent, so it is eager about a capability to perform load follow operation without changing soluble boron concentration. CPR1000, one of the main reactor types in China national development, is taken an example in this paper. It adopts a control method called Mode G, using G banks, N banks, R bank and soluble boron to perform the load follow control. According to the analysis of the physics and thermal principle, a two-node dynamic function model was built, putting the coupling coefficient and mutual influence into consideration. By the calculation of these transient parameter values which are acquired by the steady-state calculation of single channel, the core system model of CPR1000 is established. In order to carry out the load follow operation without the boron adjustment, named as BTP mode, the control banks were regrouped to control the average temperature by M banks and axial offset by AO bank. After that, the average temperature control system (M banks control system) and the axial offset control system (AO bank control system) are built. When the optimal control system is connected to the core model simulation platform, the BTP mode load follow operation of the modified CPR1000 is simulated in the end of the paper. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Implementation of Substructure Flexibility and Member-Level Load Capabilities for Floating Offshore Wind Turbines in OpenFAST

OpenFAST is an open-source, physics-based engineering tool applicable to the load analysis of land-based and offshore wind turbines, including floating offshore wind turbines. The substructure for a floating wind turbine has historically been modeled in OpenFAST as a rigid body with hydrodynamic loads lumped at a point, which enabled the tool to predict the global response of the floating substructure but not the structural loads within its individual members. This limitation is an impediment to designing floating substructures - especially newer designs that are more streamlined, flexible, and cost-effective. This paper presents the development of new functionality in OpenFAST to model floating substructure flexibility and member-level loads, as well as the concepts and mathematical background needed to understand and apply it correctly.

17 WIND ENERGY↗

Control Oriented Model of Cabin-HVAC System in a Long-Haul Trucks for Energy Management Applications

Super Truck II is a 48V mild hybrid class 8 truck with an all auxiliary loads powered purely by the battery pack. Electric Heating Ventilation and Air Conditioning (HVAC) load is the most prominent battery load during the hotel period, when the truck driver is resting inside the sleeper. For the PACCAR Super Truck II (ST-II) project a 48 V battery system provides the required power during the hotel period. A cabin-HVAC model estimates the electric load on the 48V battery system, allowing the control system to implement an efficient energy management strategy that avoids engine idling during the hotel period. The thermal model accounts for the sun load due to the time of day and the geographic location of the truck during the hotel period. The cabin-HVAC model has two parts. First, a grey box model with two heat exchangers (Condenser and Evaporator) working in unison with refrigerant mass flow rate as an input and HVAC load as an output. Second, a two-node cabin model formulated to estimate the cabin temperature as a function of the Global Horizontal Irradiance (GHI), HVAC load and ambient temperature. The models are calibrated using experimental cabin-HVAC system data as for long-haul class 8 truck (e.g. ST-II). Here, the model simulations show that the overall Root Mean Square Error (RMSE) value of 0.4°C between the experimental and simulated cabin temperature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗