At least 1,621 records · Page 90

Nanocluster production for solar cell applications

This research focuses on the fabrication and characterization of silver (Ag) and silicon (Si) nanoclusters that might be used for solar cell applications. Silver and silicon nanoclusters have been synthesized by means of dc magnetron sputtering and inert gas condensation inside an ultra-high vacuum compatible system. We have found that nanocluster size distributions can be tuned by various source parameters, such as the sputtering discharge power, flow rate of argon inert gas, and aggregation length. Quadrupole mass filter and transmission electron microscopy were used to evaluate the size distribution of Ag and Si nanoclusters. Ag nanoclusters with average size in the range of 3.6–8.3 nm were synthesized (herein size refers to the nanocluster diameter), whereas Si nanoclusters' average size was controlled to range between 2.9 and 7.4 nm by controlling the source parameters. This work illustrates the ability of controlling the Si and Ag nanoclusters' sizes by proper optimization of the operation conditions. By controlling nanoclusters' sizes, one can alter their surface properties to suit the need to enhance solar cell efficiency. Herein, Ag nanoclusters were deposited on commercial polycrystalline solar cells. Short circuit current (I{sub SC}), open circuit voltage (V{sub OC}), fill factor, and efficiency (η) were obtained under light source with an intensity of 30 mW/cm{sup 2}. A 22.7% enhancement in solar cell efficiency could be measured after deposition of Ag nanoclusters, which demonstrates that Ag nanoclusters generated in this work are useful to enhance solar cell efficiency.

36 MATERIALS SCIENCE↗

OPTIMIZATION OF A SOLAR SIMULATOR FOR PLANETARY-PHOTOCHEMICAL STUDIES

Low-temperature microwave-powered plasma based on hydrogen and hydrogen with noble gas mixtures are widely used as a continuous vacuum ultraviolet (VUV) source in laboratory experiments carried out to mimic the photochemistry in astrophysical environments. In this work, we present a study dedicated to optimizing such sources in terms of mono-chromaticity at Lyα (H(Lyα) line at 121.6 nm ∼ 10.2 eV) and high spectral irradiance. We report the influence on the emission spectrum of a wide range of experimental conditions including gas composition (pure H{sub 2}, pure He, and H{sub 2}/He mixture), gas pressure, flow rates, and microwave power. The absolute spectral irradiance delivered by this VUV light source has been measured. With a microwave input power of 100 W, the best conditions for producing a quasi-monochromatic source are a 1% H{sub 2}/He gas mixture at a total pressure of 5 mbar and a flow rate of 2 sccm. By changing the microwave input power from 30 to 120 W, H(Lyα) increases by more than one order of magnitude. A comparison between the current measurements and the solar VUV spectral irradiance is reported over 115–170 nm.

79 ASTRONOMY AND ASTROPHYSICS↗

Tunable random fiber laser

An optical fiber is treated as a natural one-dimensional random system where lasing is possible due to a combination of Rayleigh scattering by refractive index inhomogeneities and distributed amplification through the Raman effect. We present such a random fiber laser that is tunable over a broad wavelength range with uniquely flat output power and high efficiency, which outperforms traditional lasers of the same category. Outstanding characteristics defined by deep underlying physics and the simplicity of the scheme make the demonstrated laser a very attractive light source both for fundamental science and practical applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Benchmarking EUV mask inspection beyond 0.25 NA

The SEMATECH Berkeley Actinic Inspection Tool (AIT) is an EUV-wavelength mask inspection microscope designed for direct aerial image measurements, and pre-commercial EUV mask research. Operating on a synchrotron bending magnet beamline, the AIT uses an off-axis Fresnel zoneplate lens to project a high-magnification EUV image directly onto a CCD camera. We present the results of recent system upgrades that have improved the imaging resolution, illumination uniformity, and partial coherence. Benchmarking tests show image contrast above 75% for 100-nm mask features, and significant improvements and across the full range of measured sizes. The zoneplate lens has been replaced by an array of user-selectable zoneplates with higher magnification and NA values up to 0.0875, emulating the spatial resolution of a 0.35-NA 4 x EUV stepper. Illumination uniformity is above 90% for mask areas 2-{micro}m-wide and smaller. An angle-scanning mirror reduces the high coherence of the synchrotron beamline light source giving measured {sigma} values of approximately 0.125 at 0.0875 NA.

36 MATERIALS SCIENCE↗

Minimum emittance in electron storage rings with uniform or nonuniform dipoles.

A simple treatment of minimum emittance theory in storage rings is presented, favoring vector and matrix forms for a more concise picture. Both conventional uniform dipoles and nonuniform dipoles with bending radius variation are treated. Simple formulas are given for computing the minimum emittance, optimal lattice parameters, as well as effects of nonoptimal parameters. For nonuniform dipoles, analytical results are obtained for a three-piece sandwich dipole model. Minimization of the effective emittance for light sources is given in detail. Usefulness of gradient and/or nonuniform dipoles for reducing the effective emittance is addressed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis on Achieving a Minimum Bunch Length in LCLS Bunch Compressor One

An ultra-short bunch is required by different applications in many aspects. In this paper, the condition to achieve a minimum bunch length at the Linac Coherent Light Source (LCLS) [1] bunch compressor one (BC1) is analyzed analytically and evaluated by simulation. The space charge, wake field and coherent synchrotron radiation (CSR) effects are not discussed here.

43 PARTICLE ACCELERATORS↗

How Protein-Making Machine Bends Without Breaking

Scientists from several institutions including the U.S. Department of Energy's Lawrence Berkeley National Laboratory. They derived atomic-scale resolution structures of the cell's protein-making machine, the ribosome, at key stages of its job.The ability to bend but not break comes from this hinge within transfer RNA, which allows it to bend as much as 70 degrees when it passes through the ribosome during protein synthesis. The structures, developed primarily at Berkeley Lab's Advanced Light Source, reveal that the ribosome's ability to rotate an incredible amount without falling apart is due to the never-before-seen springiness of molecular widgets that hold it together.

59 BASIC BIOLOGICAL SCIENCES↗

High-Fidelity RF Gun Simulations with the Parallel 3D Finite Element Particle-In-Cell Code Pic3P

SLAC's Advanced Computations Department (ACD) has developed the first parallel Finite Element 3D Particle-In-Cell (PIC) code, Pic3P, for simulations of RF guns and other space-charge dominated beam-cavity interactions. Pic3P solves the complete set of Maxwell-Lorentz equations and thus includes space charge, retardation and wakefield effects from first principles. Pic3P uses higher-order Finite Elementmethods on unstructured conformal meshes. A novel scheme for causal adaptive refinement and dynamic load balancing enable unprecedented simulation accuracy, aiding the design and operation of the next generation of accelerator facilities. Application to the Linac Coherent Light Source (LCLS) RF gun is presented.

43 PARTICLE ACCELERATORS↗

Deep UV light generation by a fiber/bulk hybrid amplifier at 199 nm

A high-pulse-repetition-frequency (PRF) pulsed light source in the deep ultraviolet region has been realized by a multiple wavelength conversion technique using a hybrid fiber/bulk amplifier system. Output of 199 nm with a power of 50 mW was achieved at 2.4 MHz PRF. The 1 {mu}m amplifier consisted of a Yb-doped fiber amplifier and a Nd-doped YVO4 amplifier. A 1.5 {mu}m fiber master-oscillator power amplifier was employed as the other fundamental source. The amplifiers exhibited good amplification properties in pulse energy, polarization extinction ratio, and spectrum for nonlinear wavelength conversion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron beam-based sources of ultrashort x-ray pulses.

A review of various methods for generation of ultrashort x-ray pulses using relativistic electron beam from conventional accelerators is presented. Both spontaneous and coherent emission of electrons is considered. The importance of the time-resolved studies of matter at picosecond (ps), femtosecond (fs), and atttosecond (as) time scales using x-rays has been widely recognized including by award of a Nobel Prize in 1999 [Zewa]. Extensive reviews of scientific drivers can be found in [BES1, BES2, BES3, Lawr, Whit]. Several laser-based techniques have been used to generate ultrashort x-ray pulses including laser-driven plasmas [Murn, Alte, Risc, Rose, Zamp], high-order harmonic generation [Schn, Rund, Wang, Arpi], and laser-driven anode sources [Ande]. In addition, ultrafast streak-camera detectors have been applied at synchrotron sources to achieve temporal resolution on the picosecond time scale [Wulf, Lind1]. In this paper, we focus on a different group of techniques that are based on the use of the relativistic electron beam produced in conventional accelerators. In the first part we review several techniques that utilize spontaneous emission of electrons and show how solitary sub-ps x-ray pulses can be obtained at existing storage ring based synchrotron light sources and linacs. In the second part we consider coherent emission of electrons in the free-electron lasers (FELs) and review several techniques for a generation of solitary sub-fs x-ray pulses. Remarkably, the x-ray pulses that can be obtained with the FELs are not only significantly shorter than the ones considered in Part 1, but also carry more photons per pulse by many orders of magnitude.

43 PARTICLE ACCELERATORS↗

Refractive Optics for Hard X-ray Transmission Microscopy

For hard x-ray transmission microscopy at photon energies higher than 15 keV we design refractive condenser and imaging elements to be used with synchrotron light sources as well as with x-ray tube sources. The condenser lenses are optimized for low x-ray attenuation--resulting in apertures greater than 1 mm--and homogeneous intensity distribution on the detector plane, whereas the imaging enables high-resolution (<100 nm) full-field imaging. To obtain high image quality at reasonable exposure times, custom-tailored matched pairs of condenser and imaging lenses are being developed. The imaging lenses (compound refractive lenses, CRLs) are made of SU-8 negative resist by deep x-ray lithography. SU-8 shows high radiation stability. The fabrication technique enables high-quality lens structures regarding surface roughness and arrangement precision with arbitrary 2D geometry. To provide point foci, crossed pairs of lenses are used. Condenser lenses have been made utilizing deep x-ray lithographic patterning of thick SU-8 layers, too, whereas in this case, the aperture is limited due to process restrictions. Thus, in terms of large apertures, condenser lenses made of structured and rolled polyimide film are more attractive. Both condenser types, x-ray mosaic lenses and rolled x-ray prism lenses (RXPLs), are considered to be implemented into a microscope setup. The x-ray optical elements mentioned above are characterized with synchrotron radiation and x-ray laboratory sources, respectively.

07 ISOTOPE AND RADIATION SOURCES↗

Photoconductive detectors with fast temporal response for laser produced plasma experiments

Processes during laser plasma experiments typically have time scales that are less than 100 ps. The measurement of these processes requires x-ray detectors with fast temporal resolution. We have measured the temporal responses and linearity of several different x-ray sensitive photoconductive detectors (PCDs). The active elements of the detectors investigated include both diamond (natural and synthetic) and GaAs crystals. The typical time responses of the GaAs PCDs are approximately 60 ps, respectively. Some characterizations using x-ray radiation from a synchrotron radiation source are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards a Counting Point Detector for Nanosecond Coherent X-ray Science

We present the technical realization of a high-speed hard X-ray single-photon counting-detection scheme based on a commercial avalanche silicon photodiode and high-speed oscilloscope. The development is motivated by the need to perform pulse-resolved photon-correlation and pump-probe studies at synchrotron sources with densely packed pulse patterns that result in high repetition rate pulses on the order of hundreds of MHz. Commissioning experiments are performed at the 1C PAL-KRISS beamline at PLS-II of South Korea operating at a burst mode maximum repetition rate of 500 MHz. In such a high count-rate measurement, detector dead-time can lead to a distortion of counting statistics. We are able to model the counting behavior of our detector under these conditions with a detector dead-time comparable to time between X-ray pulses, implying that nanosecond X-ray photon correlation spectroscopy should be possible at diffraction-limited light sources.

36 MATERIALS SCIENCE↗

Enhanced photon-generated carrier extraction from Si nanostructure under additional infrared light irradiation

Recombination and trapping effect in quantum dots are large barriers to efficient photon-generated carrier extraction. In this paper, Infrared (IR)-assisted carrier extraction in a Si/SiO{sub 2} multiple quantum well is demonstrated. Operated at reverse bias, enhanced photoresponse from 300 to 700 nm is observed. External quantum efficiency nearly 200% is obtained when both visible light and IR are added. The enhancement is attributed to potential modulation by photo-illumination. A theoretical model including three processes is presented to explain this conclusion. The secondary light source IR could excite trapped carriers from the defects at the Si/SiO{sub 2} interface, improving extraction efficiency.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Room-temperature mid-infrared “M”-type GaAsSb/InGaAs quantum well lasers on InP substrate

We have demonstrated experimentally the InP-based “M”-type GaAsSb/InGaAs quantum-well (QW) laser lasing at 2.41 μm at room temperature by optical pumping. The threshold power density per QW and extracted internal loss were about 234 W/cm{sup 2} and 20.5 cm{sup −1}, respectively. The temperature-dependent photoluminescence (PL) and lasing spectra revealed interesting characteristics for this type of lasers. Two distinct regions in the temperature dependent threshold behavior were observed and the transition temperature was found to coincide with the cross over point of the PL and lasing emission peaks. The current-voltage characteristic of “M”-type QW laser was superior to the inverse “W”-type one due to its thinner barrier for holes. Further improvement of the “M”-type QW structure could lead to a cost-effective mid-infrared light source.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Physical nature and timing variations of the eclipsing system V407 Pegasi

New multiband CCD photometry is presented for V407 Peg; the R {sub C} light curves are the first ever compiled. Our light curves, displaying a flat bottom at secondary minimum and an O'Connell effect, were simultaneously analyzed with the radial velocity (RV) curves given by Rucinski et al. The light changes of the system are best modeled using both a hot spot on the secondary star and a third light. The model also represents historical light curves. All available minimum epochs, including our six timing measurements, have been examined and they indicate that the eclipse timing variation is mainly caused by light asymmetries due to the spot activity detected in the light-curve synthesis. The hot spot may be produced as a result of the impact of the gas stream from the primary star. Our light and velocity solutions indicate that V407 Peg is a totally eclipsing A-type overcontact binary with values of q = 0.251, i = 87.°6, ΔT = 496 K, f = 61%, and l {sub 3} = 11∼16%. Individual masses and radii of both components are determined to be M {sub 1} = 1.72 M {sub ☉}, M {sub 2} = 0.43 M {sub ☉}, R {sub 1} = 2.15 R {sub ☉}, and R {sub 2} = 1.21 R {sub ☉}. These results are very different from previous ones, which is probably caused by the light curves with distorted and inclined eclipses used in those other analyses. The fact that there are no objects optically related to the system and that the seasonal RVs show a large discrepancy in systemic velocity indicates that the third light source most likely arises from a tertiary component orbiting the eclipsing pair.

79 ASTRONOMY AND ASTROPHYSICS↗

Retraction

IN OUR 2006 REPORT, DESORPTION OF H FROM SI(111) BY RESONANT EXCITATION OF THE Si-H vibrational stretch mode (1), we reported resonant photodesorption of hydrogen from a Si(111) surface using tunable infrared radiation that corresponded to the Si-H vibrational stretch mode. Our recent attempts to reproduce these experiments have been unsuccessful, and the free electron laser facility at Vanderbilt, a unique light source for this experiment, has shut down, prohibiting further research. Because our conclusions are now in question, we retract the Report.

08 HYDROGEN↗

Programmable Spectral Source and Design Tool for 3D Imaging Using Complementary Bandpass Filters

An endoscopic illumination system for illuminating a subject for stereoscopic image capture, includes a light source which outputs light; a first complementary multiband bandpass filter (CMBF) and a second CMBF, the first and second CMBFs being situated in first and second light paths, respectively, where the first CMBF and the second CMBF filter the light incident thereupon to output filtered light; and a camera which captures video images of the subject and generates corresponding video information, the camera receiving light reflected from the subject and passing through a pupil CMBF pair and a detection lens. The pupil CMBF includes a first pupil CMBF and a second pupil CMBF, the first pupil CMBF being identical to the first CMBF and the second pupil CMBF being identical to the second CMBF, and the detection lens includes one unpartitioned section that covers both the first pupil CMBF and the second pupil CMBF.