Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “intermittency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

System and Component Development of Particle-Based Pumped Thermal Energy Storage

Reliable power supply from variable renewable resources requires energy storage at various scales to overcome resource intermittency. Long-duration energy storage (LDES, 10-100 hours) can improve dispatchability and grid reliability with increasing levels of renewable power supply. Thermal energy storage (TES) has siting flexibility and the ability to store a large capacity of energy, and thus has the potential to meet the LDES need and provide charging and discharging durations beyond the economic capacity of conventional batteries. TES technology has evolved from concentrating solar thermal power (CSP) generation and is recognized as an economic large-scale energy storage method. A standalone electric-thermal energy storage system supporting renewable integration of wind and solar power without CSP solar field can firm renewable generation and boost overall grid resilience and security.

concentrating solar thermal power↗

Evaluating Transfer and Pumping of Slurries from Pulsed Jet Mixed Vessels

Due to gravity, solids in slurries will settle if density differences between the solids and liquid are positive (i.e., particle has a negative buoyant force) unless rheological properties and flow conditions are adequate to overcome the gravitational effects. The rate of settling depends on the force balance of the particle, which includes the surface forces associated with fluid rheology. Given the same fluid and solid properties, particles that are larger and denser tend to settle faster. When pumping slurry into a vessel at concentrations precluding hindered settling with insufficient mixing, particle and density distributions can result in preferential settling, creating stratification in the solids concentration within the vessel. For vessels with transfer line inlets located in the lower portion of the tank, the stratified solids concentration may be detrimental to the transfer system performance. Elevated concentrations of solids in the slurry entrained at the inlet to the transfer line can result in the effective viscosity or slurry bulk density exceeding the design limits of the pump. These conditions could result in plugging of the transfer line or onset of cavitation of the pumps because of excessive pressure drop. These conditions can be exacerbated with periodic inlet conditions existing at the transfer line inlet. Periodic conditions can result when vessel mixing is intermittent such as with pulsed jet mixers (PJM). The transfer line inlet conditions are impacted by the periodic nature of the PJM operations with respect to suspension of solids and their transport to the inlet of the transfer line. A scaling approach is presented, and corresponding test requirements are developed for assessing the prevention of plugging the pipeline. Line plugging mechanisms are addressed that do not include plugging due to steady-state high-density slurry entering the transfer line and reducing the net positive suction head available (NPSHA) at the pump inlet to below that required for pump operation. Items considered include the transition to reduced relative flow velocities, such that the critical pipe velocity for solids deposition, Ucd, is not maintained, and segregation of heavy solids during the transport. The recommended requirements to prevent plugging include: • Limits for viscosity and density for entrained slurry to prevent the pressure drop in the pipeline from exceeding pump capacity. • Limits for viscosity and density for entrained slurry to prevent the net positive suction head available (NPSHA) from falling below the net positive suction head required (NPSHR) for operating the pump. • Transfer line velocity and flow rate requirements to maintain solids in suspension, while avoiding line plugging that results from deposition of solids within the transfer line. This paper describes the development of the scaling and testing requirements to verify that proposed approaches for transfer and pump out are appropriately developed

periodic flow, mixing, pipeline plugging, scaling,↗

High-Fidelity Simulations of a Linear HPT Vane Cascade Subject to Varying Inlet Turbulence

The effect of inflow turbulence intensity and turbulence length scales have been studied for a linear high-pressure turbine vane cascade at Reis = 590,000 and Mis = 0.93, using highly resolved compressible large-eddy simulations employing the WALE turbulence model. The turbulence intensity was varied between 6% and 20% while values of the turbulence length scales were prescribed between 5% and 20% of axial chord. The analysis focused on characterizing the inlet turbulence and quantifying the effect of the inlet turbulence variations on the vane boundary layers, in particular on the heat flux to the blade. The transition location on the suction side of the vane was found to be highly sensitive to both turbulence intensity and length scale, with the case with turbulence intensity 20% and 20% length scale showing by far the earliest onset of transition and much higher levels of heat flux over the entire vane. It was also found that the transition process was highly intermittent and local, with spanwise parts of the suction side surface of the vane remaining laminar all the way to the trailing edge even for high turbulence intensity cases.

Pichler, Richard↗

Experimental Investigation of Fuel Staging Effect on Modal Dynamics of Thermoacoustic Azimuthal Instabilities in a Multi-Nozzle Can Combustor

Abstract This paper analyzes the dynamics of unstable azimuthal thermoacoustic modes in a lean premixed combustor. Azimuthal modes can be decomposed into two counter rotating waves where they can either compete and potentially suppress one of them (spinning) or coexist (standing), depending on the operating conditions. This paper describes experimental results of the dynamical behaviors of these two waves. The experimental data were taken at different mass flow rates as well as different azimuthal fuel staging in a multi-nozzle can combustor. It is shown that at a low flow rate with uniform fuel distribution, the two waves have similar amplitudes, giving rise to a standing wave. However, the two amplitudes are slowly oscillating out of phase to each other, and the phase difference between the two waves also shows oscillatory behavior. For an intermediate flow rate, the dynamics show intermittency between standing and spinning waves, indicating that the system is bistable. In addition, the phase difference dramatically shifts when the mode switches between standing and spinning waves. For a high flow rate, the system stabilizes at a spinning wave most of the time. These experimental observations demonstrate that not only the amplitudes of two waves but also the phase difference plays an important role in the dynamics of azimuthal mode. For non-uniform azimuthal fuel staging, the modal dynamics exhibit only an oscillatory standing wave behavior regardless of the mass flow rate. Compared to the uniform fuel staging, however, the pressure magnitude is considerably reduced, which provides a potential strategy to mitigate and/or suppress the instabilities.

Kim, J.↗

Data Driven Approach to Analyzing The Impact of Power Plant Cycling on Air Preheater Degradation and Remaining Useful Life

Due to the increased penetration of renewable energy generation sources, and fluctuations of the oil and gas prices, modern coal burning power plants deal with increased variability in the demand for power generation. These varying demands result in their intermittent under-capacity operation (cycling). Periodical ramping down and back up to follow the daily power demands causes damages to the plant components reducing its operational life. In this paper we analyze the impact of cycling on a rotary Ljungstrom air preheater (APH) unit installed at a coal fire power plant in the US. An inefficient air preheater can significantly impact boiler performance. Due to the repeated boiler’s hot-cold start, the APH experiences fluctuating operating conditions that result in accelerated degradation mechanisms, such as dew-point corrosion, fouling/deposition plugging, and air heater leakage. The analysis in this paper utilizes field data related to APH basket replacement, and the number of cycles experienced by the boiler to model the life expectancy of the baskets. The data-driven model enables preventive maintenance strategies for the APH by predicting how long the APH baskets will last in a probabilistic sense. Furthermore, the analysis showed that an increase in cycling for a fixed operation time can reduce the APH basket remaining useful life by about 30%.

20 FOSSIL-FUELED POWER PLANTS↗

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics↗

X-ray wavefront sensor development at the Advanced Light Source

At Lawrence Berkeley National Laboratory's Advanced Light Source, we are developing x-ray wavefront sensors to support the creation and operation of beamlines with diffraction-limited quality. Our new approach to rapid, intermittent wavefront sensing operates in reflection at glancing incidence angles and is compatible with the high-power densities of modern beamlines. For soft x-ray applications especially, the wavefront sensor can operate upstream of the exit slit in a vertically dispersed beam. This single-shot technique supports lateral shearing interferometry and Hartmann wavefront sensing; it can be adapted to speckle-based techniques as well. The reflected beam is directed to an off-axis YAG crystal that produces scintillated visible light. A small mirror reflects the light to a microscope and camera, and the measured wavefront shape information can be used as feedback to adaptive x-ray mirror elements. A compact array of gratings enables measurement across a broad range of photon energies or wavefront curvatures. We describe recent demonstrations at soft x-ray and hard x-ray wavelengths measuring an adaptive x-ray mirror, and a toroidal focusing mirror.

Goldberg, Kenneth A↗

Large-area low-temperature ultrananocrystaline diamond (UNCD) films and integration with CMOS devices for monolithically integrated diamond MEMD/NEMS-CMOS systems.

Because of exceptional mechanical, chemical, and tribological properties, diamond has a great potential to be used as a material for the development of high-performance MEMS and NEMS such as resonators and switches compatible with harsh environments, which involve mechanical motion and intermittent contact. Integration of such MEMS/NEMS devices with complementary metal oxide semiconductor (CMOS) microelectronics will provide a unique platform for CMOS-driven commercial MEMS/NEMS. The main hurdle to achieve diamond-CMOS integration is the relatively high substrate temperatures (600-800 C) required for depositing conventional diamond thin films, which are well above the CMOS operating thermal budget (400 C). Additionally, a materials integration strategy has to be developed to enable diamond-CMOS integration. Ultrananocrystalline diamond (UNCD), a novel material developed in thin film form at Argonne, is currently the only microwave plasma chemical vapor deposition (MPCVD) grown diamond film that can be grown at 400 C, and still retain exceptional mechanical, chemical, and tribological properties comparable to that of single crystal diamond. We have developed a process based on MPCVD to synthesize UNCD films on up to 200 mm in diameter CMOS wafers, which will open new avenues for the fabrication of monolithically integrated CMOS-driven MEMS/NEMS based on UNCD. UNCD films were grown successfully on individual Si-based CMOS chips and on 200 mm CMOS wafers at 400 C in a MPCVD system, using Ar-rich/CH4 gas mixture. The CMOS devices on the wafers were characterized before and after UNCD deposition. All devices were performing to specifications with very small degradation after UNCD deposition and processing. A threshold voltage degradation in the range of 0.08-0.44V and transconductance degradation in the range of 1.5-9% were observed.

36 MATERIALS SCIENCE↗

SU-E-J-223: A BOLD Contrast Imaging Sequence to Evaluate Oxygenation Changes Due to Breath Holding for Breast Radiotherapy: A Pilot Study

Purpose: To develop a robust MRI sequence to measure BOLD breath hold induced contrast in context of breast radiotherapy. Methods: Two sequences were selected from prior studies as candidates to measure BOLD contrast attributable to breath holding within the breast: (1) T2* based Gradient Echo EPI (TR/TE = 500/41ms, flip angle = 60°), and (2) T2 based Single Shot Fast Spin Echo (SSFSE) (TR/TE = 3000/60ms). We enrolled ten women post-lumpectomy for breast cancer who were undergoing treatment planning for whole breast radiotherapy. Each session utilized a 1.5T GE MRI and 4 channel breast coil with the subject immobilized prone on a custom board. For each sequence, 1–3 planes of the lumpectomy breast were imaged continuously during a background measurement (1min) and intermittent breath holds (20–40s per breath hold, 3–5 holds per sequence). BOLD contrast was quantified as correlation of changes in per-pixel intensity with the breath hold schedule convolved with a hemodynamic response function. Subtle motion was corrected using a deformable registration algorithm. Correlation with breath-holding was considered significant if p<0.001. Results: The percentage of the breast ROI with positive BOLD contrast measured by the two sequences were in agreement with a correlation coefficient of R=0.72 (p=0.02). While both sequences demonstrated areas with strong BOLD response, the response was more systematic throughout the breast for the SSFSE (T2) sequence (% breast with response in the same direction: 51.2%±0.7% for T2* vs. 68.1%±16% for T2). In addition, the T2 sequence was less prone to magnetic susceptibility artifacts, especially in presence of seroma, and provided a more robust image with little distortion or artifacts. Conclusion: A T2 SSFSE sequence shows promise for measuring BOLD contrast in the context of breast radiotherapy utilizing a breath hold technique. Further study in a larger patient cohort is warranted to better refine this novel technique.

60 APPLIED LIFE SCIENCES↗

SU-E-T-133: Assessing IMRT Treatment Delivery Accuracy and Consistency On a Varian TrueBeam Using the SunNuclear PerFraction EPID Dosimetry Software

Purpose: To assess if the TrueBeam HD120 collimator is delivering small IMRT fields accurately and consistently throughout the course of treatment using the SunNuclear PerFraction software. Methods: 7-field IMRT plans for 8 canine patients who passed IMRT QA using SunNuclear Mapcheck DQA were selected for this study. The animals were setup using CBCT image guidance. The EPID fluence maps were captured for each treatment field and each treatment fraction, with the first fraction EPID data serving as the baseline for comparison. The Sun Nuclear PerFraction Software was used to compare the EPID data for subsequent fractions using a Gamma (3%/3mm) pass rate of 90%. To simulate requirements for SRS, the data was reanalyzed using a Gamma (3%/1mm) pass rate of 90%. Low-dose, low- and high gradient thresholds were used to focus the analysis on clinically relevant parts of the dose distribution. Results: Not all fractions could be analyzed, because during some of the treatment courses the DICOM tags in the EPID images intermittently change from CU to US (unspecified), which would indicate a temporary loss of EPID calibration. This technical issue is still being investigated. For the remaining fractions, the vast majority (7/8 of patients, 95% of fractions, and 96.6% of fields) are passing the less stringent Gamma criteria. The more stringent Gamma criteria caused a drop in pass rate (90 % of fractions, 84% of fields). For the patient with the lowest pass rate, wet towel bolus was used. Another patient with low pass rates experienced masseter muscle wasting. Conclusion: EPID dosimetry using the PerFraction software demonstrated that the majority of fields passed a Gamma (3%/3mm) for IMRT treatments delivered with a TrueBeam HD120 MLC. Pass rates dropped for a DTA of 1mm to model SRS tolerances. PerFraction pass rates can flag missing bolus or internal shields. Sanjeev Saini is an employee of Sun Nuclear Corporation. For this study, a pre-release version of PerFRACTION 1.1 software from Sun Nuclear Corporation was used.

60 APPLIED LIFE SCIENCES↗

TU-G-BRA-07: Characterization of Tumor Proliferation During Successive Cycles of Anti-Angiogenic Therapy Using [F-18]FLT PET/CT

Purpose: Studies have shown cessation of anti-angiogenic treatment during the first cycle of therapy resulted in rebound of tumor proliferation (flare). This study characterized proliferation dynamics during the first and third cycle of anti-angiogenic treatment using [F-18]FLT PET. Methods: Thirteen patients with various solid cancers were treated with Axitinib (Pfizer, Inc) at a dose of 5mg orally, twice daily, on contiguous three-week cycles with intermittent dosing (two-weeks-on/one-week-off). All patients received three FLT PET/CT scans during cycle 1 (C1): at baseline (C1D0), peak Axitinib concentration (C1D14), and the end of washout (C1D21). Ten patients received up to an additional three scans at corresponding time points during cycle 3 (C3). Lesions were identified by a nuclear medicine physician and manually contoured. Tumor burden was quantified using standard SUV metrics. Correlations between imaging metrics across C1 and C3 were calculated using the Spearman correlation. Results: At C1 peak drug concentration 11/13 patients had decreases in SUVtotal, with median decrease of 50% (change from C1D0 to C1D14). At C3 peak drug concentration 7/7 patients had decreases in SUVtotal, with median decrease of 20% (C3D0 to C3D14). Proliferative flare during C1 washout (>20% increase from C1D14 to C1D21) occurred in 9/13 patients, with median SUVtotal increase of 190%. Flare was also seen in C3 for 5/5 patients, with median SUVtotal increase of 70% (change from C3D14 to C3D21). Correlations were found between changes in imaging metrics across C1 and C3, notably the change in SUVtotal from C1D0 to C1D21 and the change in SUVtotal from C1D0 to C3D0 (ρ = 0.80). Conclusion: Measurements of SUVtotal showed that both patient response to treatment and flare were evident in both cycles of treatment. Correlation between changes in SUVtotal across C1 and C3 suggest early time points could be used to characterize patient response in later cycles. Research funded in part by Pfizer.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-06: Correlation of Lung Tumor Motion with Tumor Location Using Electromagnetic Tracking

Purpose: It is well known that lung tumors move with respiration. However, most measurements of lung tumor motion have studied long treatment times with intermittent imaging; those populations may not necessarily represent conventional LINAC patients. We summarized the correlation between tumor motion and location in a multi-institutional trial with electromagnetic tracking, and identified the patient cohort that would most benefit from respiratory gating. Methods: Continuous electromagnetic transponder data (Varian Medical, Seattle, WA) of lung tumor motion was collected from 14 patients (214 total fractions) across 3 institutions during external beam radiation therapy in a prospective clinical trial (NCT01396551). External intervention from the clinician, such as couch shifts, instructed breath-holds, and acquisition pauses, were manually removed from the 10 Hz tracking data according to recorded notes. The average three-dimensional displacement from the breathing cycle’s end-expiratory to end-inhalation phases (peak-to-peak distance) of the transponders’ isocenter was calculated for each patient’s treatment. A weighted average of each isocenter was used to assess the effects of location on motion. A total of 14 patients were included in this analysis, grouped by their transponders’ location in the lung: upper, medial, and lower. Results: 8 patients had transponders in the upper lung, and 3 patients each in the medial lobe and lower lung. The weighted average ± standard deviation of all peak-to-peak distances for each group was: 1.04 ± 0.39 cm in the lower lung, 0.56 ± 0.14 cm in the medial lung, and 0.30 ± 0.06 cm in the upper lung. Conclusion: Tumors in the lower lung are most susceptible to excessive motion and daily variation, and would benefit most from continuous motion tracking and gating. Those in the medial lobe might be at moderate risk. The upper lobes have limited motion. These results can guide different motion management strategies between lung tumor locations. This is part of an NIH-funded prospective clinical trial (NCT01396551), using an electromagnetic transponder tracking system and additional funding from Varian Medical (Seattle, WA).

60 APPLIED LIFE SCIENCES↗

MO-AB-BRA-06: Dynamic FLT PET for Investigating Potential Synergistic Therapeutic Targets During Anti-Angiogenic Treatment

Purpose: Novel treatment strategies for metastatic cancer patients involve synergistically combining treatments with the hope of improving outcomes. This study investigated changes in tumor proliferative and vascular characteristics derived from dynamic [F-18]FLT PET during antiangiogenic treatment with the goal of identifying synergistic treatment opportunities. Methods: Patients with various solid cancers underwent continuous three-week cycles of anti-angiogenic treatment with intermittent dosing (two-weeks-on/one-week-off). Patients received up to six dynamic FLT PET/CT scans (days 0, 14, and 21 of cycle 1 (C1) and cycle 3 (C3)). Tumor proliferative (Kflt, net uptake rate) and vascular parameters (K1 blood-to-tissue transfer; Vb, vascular fraction) were calculated using a two-tissue compartment four-rate parameter kinetic model. Relative changes in these parameters, from day 0 to 14 (TxResp) and day 14 to 21 (offTxResp), were calculated. Significant differences were tested using Wilcoxon signed-rank test and significant correlations were tested using Spearman correlation. Results: Thirty patients were evaluable for C1 offTxResp with median values for Kflt, K1, and Vb of +30%, +35% and +30%, respectively. The fractions of patients with positive C1 offTxResp were: 21/30 for Ki, 24/30 for K1, 21/30 for Vb, and 12/30 had positive offTxResp for all three kinetic parameters. The offTxResp in C3 was not significantly different from C1 for any of the kinetic parameters. Significant correlations were found between TxResp and offTxResp in C1 for Kflt (ρ=-0.52, p=0.014), K1 (ρ=−0.61, p=0.003) and Vb (ρ=−0.80, p<0.001). Similar correlations were found for Kflt (ρ=-1, p=0.017) and K1 (ρ=−1, p=0.017) for the five patients evaluable in C3. Conclusion: Dynamic FLT PET showed evidence of distinct vascular and proliferative increases during off treatment weeks that could potentially be targeted with synergistic therapy. Early changes in kinetic parameters were correlated with later changes suggesting potential for early prediction of vascular and proliferative changes during off treatment weeks.

60 APPLIED LIFE SCIENCES↗

WE-FG-BRA-08: Potential Role of the Glycolytic Oscillator in Acute Hypoxia in Tumors

Purpose: Oscillatory dynamics in acute hypoxia have been observed, but poorly understood. They have mostly been attributed to vascular perturbations, but no link has yet been made to metabolic causes. We set out to determine the fundamental frequencies and test for coherence in tumor oxygen dynamics and spatial properties. Methods: Severe combined immunodeficient (SCID) mice were inoculated onto bilateral flanks with human derived head and neck carcinoma (UW-SCC22) cell line xenografts. Oxygen dynamics were monitored in the tumor every minute for an hour using three modalities: blood oxygen level dependent - magnetic resonance imaging (BOLD-MRI), hemoglobin oxygen saturation photoacoustic, and locally manufactured optical probes for spectral fitting. A statistical test was used to separate fluctuating from non-fluctuating voxels and pixels in BOLD-MRI and photoacoustic data respectively. The power spectrum density (PSD) and the autocorrelation functions were calculated for the time series of each voxel, pixel and region, of the BOLD-MRI, photoacoustic or fiber optic data respectively. Results: Using all three techniques, intermittent oxygen dynamics with both coherent and incoherent signatures was observed in the tumors. Upon averaging the PSDs of fluctuating voxels and pixels, it was found that these oscillations occurred with periods of minutes to tens of minutes from all three approaches. Observations from the BOLD-MRI and photoacoustic data showed that clusters of voxels oscillated in a synchronized manner. Conclusion: We were able to use three different modalities to show that fluctuation in tumor oxygen is both coherent and incoherent, with periods of minutes to tens of minutes. These periods are very similar to those from the well-established metabolic, non-linear biomechanical phenomenon called the glycolytic oscillator. This may provide an additional explanation to the cause of cyclic hypoxia. Such dynamics could have profound implications in hypofractionated radiotherapy regiments and could help guide treatment and make it more patient specific. The authors would like to thank the University of Wisconsin Carbone Cancer Center (UWCCC) for the funds to complete this project. This work is also supported in part by NIH/NCI P30 CA014520- UW Comprehensive Cancer Center Support”.

60 APPLIED LIFE SCIENCES↗

Swirls and scoops: Ice base melt revealed by multibeam imagery of an Antarctic ice shelf

Knowledge gaps about how the ocean melts Antarctica’s ice shelves, borne from a lack of observations, lead to large uncertainties in sea level predictions. Using high-resolution maps of the underside of Dotson Ice Shelf, West Antarctica, we reveal the imprint that ice shelf basal melting leaves on the ice. Convection and intermittent warm water intrusions form widespread terraced features through slow melting in quiescent areas, while shear-driven turbulence rapidly melts smooth, eroded topographies in outflow areas, as well as enigmatic teardrop-shaped indentations that result from boundary-layer flow rotation. Full-thickness ice fractures, with bases modified by basal melting and convective processes, are observed throughout the area. This new wealth of processes, all active under a single ice shelf, must be considered to accurately predict future Antarctic ice shelf melt.

54 ENVIRONMENTAL SCIENCES↗

A Synthetic Nickel Electrocatalyst With a Turnover Frequency Above 100,000 s-1 for H2 Production

Increased worldwide energy demand will require greater use of carbon-neutral sustainable energy sources. The intermittent nature of solar and wind power requires storage of energy, so electrocatalysts that convert electrical energy to chemical bonds in fuels are needed. Platinum is an excellent catalyst, but it is of low abundance and high cost. Hydrogenase enzymes in Nature catalyze the evolution of H2 and use earth-abundant metals such as nickel and iron. We report that a synthetic nickel catalyst, [Ni(7PPh2NPh)2](BF4)2, (7PPh2NPh = 1,3,6-triphenyl-1-aza-3,6-diphosphacycloheptane) catalyzes the production of H2 using [(DMF)H]+OTf as the proton source, with turnover frequencies of 31,000 s-1 in dry acetonitrile and 108,000 s-1 in the presence of H2O (1.2 M), at a potential of -1.13 V (vs. the ferrocenium/ferrocene couple). These turnover frequencies exceed those reported for the [FeFe] hydrogenase enzyme by more than an order of magnitude, and are the fastest reported for any molecular catalyst for H2 production. This material is based upon work supported as part of the Center for Molecular Electrocatalysis, an Energy Frontier Research Center funded by the US Department of Energy, Office of Science, Office of Basic Energy Sciences.

17 WIND ENERGY↗

Cracking the failure of lithium batteries

Lithium batteries that use a solid electrolyte have the potential to improve safety and increase the amount of stored energy . This makes solid-state electrochemical cells a promising option for electric vehicles and wearable devices. However, nonuniform plating or stripping of lithium at the interface between an anode (negative electrode) and the electrolyte during charging and discharging leads to growth of detrimental lithium filaments (dendrites) that short-circuit the battery cell. This problem even occurs when the battery operates at small currents. The underlying mechanism of this failure is not well understood. On page 311 of this issue, Wang et al. (1) report that structural defects accumulate in the lithium metal anode under repeated charging and discharging at a small current. This is similar to mechanical fatigue that is observed over longer periods of intermittent straining of a material. Here, the observation could guide the design of lithium batteries with increased life span.

25 ENERGY STORAGE↗

Dynamics of Microbial Community Composition and Function during In Situ Bioremediation of a Uranium-Contaminated Aquifer

A pilot-scale system was established to examine the feasibility of in situ U(VI) immobilization at a highly contaminated aquifer (U.S. DOE Integrated Field Research Challenge site, Oak Ridge, TN). Ethanol was injected intermittently as an electron donor to stimulate microbial U(VI) reduction, and U(VI) concentrations fell to below the Environmental Protection Agency drinking water standard (0.03 mg liter 1). Microbial communities from three monitoring wells were examined during active U(VI) reduction and maintenance phases with GeoChip, a high-density, comprehensive functional gene array. The overall microbial community structure exhibited a considerable shift over the remediation phases examined. GeoChip-based analysis revealed that Fe(III)-reducing bacterial (FeRB), nitrate-reducing bacterial (NRB), and sulfate-reducing bacterial (SRB) functional populations reached their highest levels during the active U(VI) reduction phase (days 137 to 370), in which denitrification and Fe(III) and sulfate reduction occurred sequentially. A gradual decrease in these functional populations occurred when reduction reactions stabilized, suggesting that these functional populations could play an important role in both active U(VI) reduction and maintenance of the stability of reduced U(IV). These results suggest that addition of electron donors stimulated the microbial community to create biogeochemical conditions favorable to U(VI) reduction and prevent the reduced U(IV) from reoxidation and that functional FeRB, SRB, and NRB populations within this system played key roles in this process.

54 ENVIRONMENTAL SCIENCES↗