Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging and visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Real-time atomic-resolution imaging of crystal growth process in water by phase modulation atomic force microscopy at one frame per second

Recent advancement in dynamic-mode atomic force microscopy (AFM) has enabled its operation in liquid with atomic-scale resolution. However, its imaging speed has often been too slow to visualize atomic-scale dynamic processes. Here, we propose a method for making a significant improvement in the operation speed of dynamic-mode AFM. In this method, we use a wideband and low-latency phase detector with an improved algorithm for the signal complexification. We demonstrate atomic-scale imaging of a calcite crystal growth process in water at one frame per second. The significant improvement in the imaging speed should enable various studies on unexplored atomic-scale interfacial processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stimulus-response incompatibility activates cortex proximate to three eye fields

We used functional magnetic resonance imaging (fMRI) to investigate cortical activation during the performance of three oculomotor tasks that impose increasing levels of cognitive demand. (1) In a visually guided saccade (VGS) task, subjects made saccades to flashed targets. (2) In a compatible task, subjects made leftward and rightward saccades in response to foveal presentation of the uppercase words "LEFT" or "RIGHT." (3) In a mixed task, subjects made rightward saccades in response to the lowercase word "left" and leftward saccades in response to the lowercase word "right" on incompatible trials (60%). The remaining 40% of trials required compatible responses to uppercase words. The VGS and compatible tasks, when compared to fixation, activated the three cortical eye fields: the supplementary eye field (SEF), the frontal eye field (FEF), and the parietal eye field (PEF). The mixed task, when compared to the compatible task, activated three additional cortical regions proximate to the three eye fields: (1) rostral to the SEF in medial frontal cortex; (2) rostral to the FEF in dorsolateral prefrontal cortex (DLPFC); (3) rostral and lateral to the PEF in posterior parietal cortex. These areas may contribute to the suppression of prepotent responses and in holding novel visuomotor associations in working memory. Copyright 2001 Academic Press.

NASA Discipline Neuroscience↗

Trial of a proposed protocol for constancy control of digital mammography systems

Purpose: Evaluate the utility of tests in a proposed protocol for constancy control of digital mammography systems. Methods: The protocol contained tests for image acquisition, mechanical function and safety, monitors and printers, and viewing conditions. Nine sites with digital systems from four equipment manufacturers were recruited. Dedicated PMMA test objects and Excel spreadsheets were developed. Quantitative measurements were done on processed images for systems where these images were the ones most readily available. For daily assessment of the automatic exposure control system, a homogeneous PMMA phantom was exposed under clinical conditions. The mAs and signal to noise ratio (SNR) were recorded, the deviation from a target value calculated, and the resulting image inspected for artifacts. For thickness tracking, the signal difference to noise ratio obtained for three thicknesses was calculated. Detector uniformity was assessed through comparison of SNR values for regions of interest in the center and corners of an image of a homogeneous test object. Mechanical function and safety control included a compression test, a checklist for mechanical aspects, and control of field alignment. Monitor performance was evaluated by visual inspection of the AAPM TG 18 QC test image [E. Samei et al., ''Assessment of display performance for medical imaging systems,'' Task Group 18 (Madison, WI, April 2005)]. Results: For quantitative parameters, target values and tolerance limits were established. Test results exceeding the limits were registered. Most systems exhibited stable mAs values, indicating that the tolerance limit of {+-}10% was readily achievable. The SNR also showed little variation, indicating that the tolerance limit of {+-}20% was too wide. At one site, a defective grid caused artifacts that were visible in the test images. The monitor controls proved more difficult to implement due to both difficulties importing and displaying the test image, and the radiographic technologists not getting necessary access to the reading stations. Conclusions: The proposed tests could easily be performed by trained radiographic technologists and within a time frame comparable to similar programs for analog systems. Tests with quantitative measures were more readily performed than procedures that required a subjective evaluation. Several of the proposed tests revealed equipment performance that required intervention, and which would otherwise have gone unnoticed. They therefore defend a place in a vendor-independent constancy control protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative comparison of noise texture across CT scanners from different manufacturers

Purpose: To quantitatively compare noise texture across computed tomography (CT) scanners from different manufacturers using the noise power spectrum (NPS). Methods: The American College of Radiology CT accreditation phantom (Gammex 464, Gammex, Inc., Middleton, WI) was imaged on two scanners: Discovery CT 750HD (GE Healthcare, Waukesha, WI), and SOMATOM Definition Flash (Siemens Healthcare, Germany), using a consistent acquisition protocol (120 kVp, 0.625/0.6 mm slice thickness, 250 mAs, and 22 cm field of view). Images were reconstructed using filtered backprojection and a wide selection of reconstruction kernels. For each image set, the 2D NPS were estimated from the uniform section of the phantom. The 2D spectra were normalized by their integral value, radially averaged, and filtered by the human visual response function. A systematic kernel-by-kernel comparison across manufacturers was performed by computing the root mean square difference (RMSD) and the peak frequency difference (PFD) between the NPS from different kernels. GE and Siemens kernels were compared and kernel pairs that minimized the RMSD and |PFD| were identified. Results: The RMSD (|PFD|) values between the NPS of GE and Siemens kernels varied from 0.01 mm{sup 2} (0.002 mm{sup -1}) to 0.29 mm{sup 2} (0.74 mm{sup -1}). The GE kernels 'Soft,''Standard,''Chest,' and 'Lung' closely matched the Siemens kernels 'B35f,''B43f,''B41f,' and 'B80f' (RMSD < 0.05 mm{sup 2}, |PFD| < 0.02 mm{sup -1}, respectively). The GE 'Bone,''Bone+,' and 'Edge' kernels all matched most closely with Siemens 'B75f' kernel but with sizeable RMSD and |PFD| values up to 0.18 mm{sup 2} and 0.41 mm{sup -1}, respectively. These sizeable RMSD and |PFD| values corresponded to visually perceivable differences in the noise texture of the images. Conclusions: It is possible to use the NPS to quantitatively compare noise texture across CT systems. The degree to which similar texture across scanners could be achieved varies and is limited by the kernels available on each scanner.

60 APPLIED LIFE SCIENCES↗

A Public-Private-Academic Partnership to Advance Solar Power Forecasting

Executive Summary NOAA is making major contributions to the solar forecasting project in three areas. First, it is improving its forecasts of solar irradiance, clouds, and aerosols in its numerical weather prediction models. Second, it is providing advanced satellite products for DOE's FOA awardees to use in their forecast systems. Third, it is using high-quality ground-based measurements from SURFRAD and ISIS stations to verify and validate forecast model output. This reports covers results from all three areas for the period May 1, 2014 - April 30, 2015. Modeling In its modeling effort, NOAA continues work to improve the skill of solar forecasts from the Earth System Research Lab (ESRL) research versions of the 13-km Rapid Refresh (RAP) and the 3-km High-Resolution Rapid Refresh (HRRR) models, which are in turn transitioned into operations at the National Centers for Environmental Prediction (NCEP). A major milestone was achieved in September 2014 with the initial operational implementation of the HRRR at NCEP. In the ESRL research versions of the models, testing and development, in both real-time runs and retrospective experiments, is guided by an extensive in-house verification system. Early in the SFIP project, we developed the capability to verify our model forecasts against the high-quality surface radiation measurements from the SURFRAD and ISIS networks. This highlighted some shortcomings with the RAP and HRRR forecasts of incoming shortwave radiation. Most of our effort during Phase 1 of SFIP was focused on addressing these problems with a variety of model system improvements. The RAP and HRRR models during the warm season of 2014 had a noticeable warm and dry bias in near-surface conditions over most of the central and eastern United States, and our new SURFRAD/ISIS verification revealed that there was also a large excess of incoming global horizontal irradiance in the models. We hypothesized that a lack of cloud cover (particularly low-level cloud cover) in the models was resulting in too much heating of the land surface. This, in turn, caused unrealistically strong surface heat fluxes and turbulent mixing in the planetary boundary layer (PBL), which further reduced the already deficient cloud cover. We addressed these issues with a combination of data assimilation system modifications and model physics improvements. Many of our data assimilation changes were made with a view towards improving the near-term representation of clouds and precipitation. One of these changes involved better accounting for regions of weak reflectivity in the RAP cloud / hydrometeor assimilation system, in order to improve the representation of light precipitation in the RAP initial conditions and provide more realistic initial cloud cover. Additional modifications more accurately accounted for radar beam blockage and data gaps (particularly in the western United States), which improves shorter lead times forecasts of clouds and precipitation. We have also tested the assimilation of new data sources within the RAP and the HRRR, including radar radial velocity data and surface mesonet observations. Within the HRRR, we have tested the cycling of the 3-km land surface fields to allow a higher-resolution treatment of land surface processes. In terms of model physics development for SFIP, we have implemented a shallow cumulus scheme within the RAP, and have made numerous improvements to the Mellor-Yamada-Nakanishi-Niino (MYNN) PBL scheme to address insufficient low-level cloud cover in the models. We have conducted tests incorporating the radiation effects of (parameterized) boundary-layer clouds within the modified MYNN PBL scheme (independent of the convective schemes). The Grell-Freitas-Olson shallow cumulus scheme has also been tested within the 3-km HRRR. Finally, we have also modified the RUC land surface model (LSM) treatment of the vegetation wilting point, reducing it to increase evapotranspiration and increase cloud cover in the boundary layer. All of these changes work in tandem to significantly improve the model forecasts of cloud cover, incoming shortwave radiation, and near-surface temperature and moisture. Satellite The role of NOAA/NESDIS in the Solar Forecasting Improvement Project is to provide Advanced Satellite Products (ASPs) for the two forecasting teams at NCAR and IBM. The ASPs are cloud, surface, and atmosphere products derived from geostationary satellite imagery at the highest possible spatial and temporal resolution - such quantities as cloud mask, cloud probability, cloud transmission, cloud top height, cloud top temperature, cloud effective particle size, etc. Ancillary data, such as elevation and numerical weather prediction fields are provided in the files at the same resolution as well. There are at this time 147 different variables in the ASP output, including quality flags and processing information. The main goals for Year 1 of the project were to implement an Advanced Satellite Products system for the use of the IBM and NCAR teams, begin validation, and make any needed changes based on feedback from the teams. ASP files are being produced every GOES Imager acquisition, which occur on a 15-30 minute schedule. Processing is done on a dedicated computer, with a turn-around time of 8-21 minutes from image acquisition to results available on ftp. Several helpful visualizations of the data are also created for users on web pages. Users have been provided with a document titled "User's Guide for 1km Cloud Products Derived from GOES Imager Data using CLAVR-x", which discusses the basics of the source imagery, the process by which it is turned into Advanced Satellite Products, and considerations users should make when using the data. Validation of selected variables from the older 4km version of the products was also included. Future work will concentrate on validation of the 1km products and improving the turn-around time, product variety, and product quality as needed. Ground Observations In the ground-based measurement effort, NOAA's main objectives are to provide high quality radiation products for validation and verification of short-term to day-ahead solar forecasts. More specifically for the three year project, our goals include (1) Maintaining and providing data from our 7 SURFRAD and 7 ISIS; (2) Update ISIS radiation measurements from 3 min to 1 min data: (3) Purchase and install new pyrheliometers for direct solar irradiance measurements at the 7 SURFRAD sites; (4) Building, testing, and deploying two mobile SURFRAD stations at two utility plants in collaboration with DOE sponsored partners, and includes ongoing maintenance and processing of the data at the mobile sites; (5) Upgrading the data acquisition and communications at 7 SURFRAD sites and 7 ISIS sites; (6) Providing radiation data at the 7 SURFRAD sites in near real-time; (7) Develop and provide aerosol optical depth and cloud images and cloud fraction at our two mobile sites; (8) Provide data recovery rates each year; (9) Provide temporally and spatially averaged radiation products for comparison to HRRR and RAP solar forecasts and advanced satellite products; (10) Provide a data-set for analysis of conversion of direct and diffuse to sloped surfaces; (11) and as time permits develop and provide spectral solar irradiance, cloud optical depth and spectral albedo from the mobile sites. Milestones this year include working with the DOE sponsored teams to find locations to deploy two mobile SURFRAD stations. One existing unit was deployed at a 30MW PV facility in the San Luis Valley in collaboration with Xcel and the NCAR team in August, 2014. The second unit was built and tested at our facilities in Boulder, CO and deployed near Green Mountain Power's Education Center in Rutland, VT in collaboration with Green Mountain Power and the IBM Team in October, 2014. Data processing was implemented and the radiation data from these two mobile sites have been made available on our ftp server in near real-time. We also are providing images and cloud fraction from the TSI cameras for these two mobile sites on our ftp site. Another milestone was upgrading our data acquisition and communication systems at 7 SURFRAD and 7 ISIS sites. We accelerated our schedule for these upgrades to provide timely radiation products. These upgrades allow more reliable and near-real time radiation data delivery to the DOE sponsored teams to meet their goals. Lastly, we changed the data rate at the ISIS sites from 3 min to 1 min.

14 SOLAR ENERGY↗

TU-CD-207-08: Intrinsic Image Quality Comparison of Synthesized 2-D and FFDM Images

Purpose: With the combined interest of managing patient dose, maintaining or improving image quality, and maintaining or improving the diagnostic utility of mammographic data, this study aims to compare the intrinsic image quality of Hologic’s synthesized 2-D (C-View) and 2-D FFDM images in terms of resolution, contrast, and noise. Methods: This study utilized a novel 3-D printed anthropomorphic breast phantom in addition to the American College of Radiology (ACR) mammography accreditation phantom. Analysis of the 3-D anthropomorphic phantom included visual assessment of resolution and analysis of the normalized noise power spectrum. Analysis of the ACR phantom included both visual inspection and objective automated analysis using in-house software. The software incorporates image- and object-specific CNR visibility thresholds which account for image characteristics such as noise texture which affect object visualization. T- test statistical analysis was also performed on ACR phantom scores. Results: The spatial resolution of C-View images is markedly lower (at least 50% worse) than that of FFDM. And while this is generally associated with the benefit of reduced relative noise magnitude, the noise in C-View images tends to have a more mottled (predominantly low-frequency) texture. In general, for high contrast objects, C-View provides superior visualization over FFDM; however this benefit diminishes for low contrast objects and is applicable only to objects that are sufficiently larger than the spatial resolution threshold. Based on both observer and automated ACR phantom analysis, between 50–70% of C-View images failed to meet ACR minimum accreditation requirements – primarily due to insufficient (unbroken) fiber visibility. Conclusion: Compared to FFDM, C-View offers better depiction of objects of certain size and contrast, but provides poorer overall resolution and noise properties. Based on these findings, the utilization of C-View images in the clinical setting requires careful consideration, especially if considering the discontinuation of FFDM imaging.

60 APPLIED LIFE SCIENCES↗

Gaze as a biometric

Two people may analyze a visual scene in two completely different ways. Our study sought to determine whether human gaze may be used to establish the identity of an individual. To accomplish this objective we investigated the gaze pattern of twelve individuals viewing different still images with different spatial relationships. Specifically, we created 5 visual dot-pattern tests to be shown on a standard computer monitor. These tests challenged the viewer s capacity to distinguish proximity, alignment, and perceptual organization. Each test included 50 images of varying difficulty (total of 250 images). Eye-tracking data were collected from each individual while taking the tests. The eye-tracking data were converted into gaze velocities and analyzed with Hidden Markov Models to develop personalized gaze profiles. Using leave-one-out cross-validation, we observed that these personalized profiles could differentiate among the 12 users with classification accuracy ranging between 53% and 76%, depending on the test. This was statistically significantly better than random guessing (i.e., 8.3% or 1 out of 12). Classification accuracy was higher for the tests where the users average gaze velocity per case was lower. The study findings support the feasibility of using gaze as a biometric or personalized biomarker. These findings could have implications in Radiology training and the development of personalized e-learning environments.

eye tracking↗

Evaluation of camera-based freehand SPECT in preoperative sentinel lymph node mapping for melanoma patients

Assessment of lymphatic status via sentinel lymph node (SLN) biopsy is an integral and crucial part of melanoma surgical oncology. The most common technique for sentinel node mapping is preoperative planar scintigraphy of an injected gamma-emitting lymphatic tracer followed by intraoperative node localization using a non-imaging gamma probe with auditory feedback. In recent years, intraoperative visualization of SLNs in 3D has become possible by coupling the probe to an external system capable of tracking its location and orientation as it is read out, thereby enabling computation of the 3D distribution of the tracer (freehand SPECT). In this project, the non-imaging probe of the fhSPECT system was replaced by a unique handheld gamma camera containing an array of sodium iodide crystals optically coupled to an array of silicon photomultipliers (SiPMs). A feasibility study was performed in which preoperative SLN mapping was performed using camera fhSPECT and the number of detected nodes was compared to that visualized by lymphoscintigraphy, probe fhSPECT, and to the number ultimately excised under non-imaging probe guidance. Among five subjects, SLNs were detected in nine lymphatic basins, with one to five SLNs detected per basin. A basin-by-basin comparison showed that the number of SLNs detected using camera fhSPECT exceeded that using lymphoscintigraphy and probe fhSPECT in seven of nine basins and five of five basins, respectively. (Probe fhSPECT scans were not performed for four basins.) It exceeded the number excised under non-imaging probe guidance for seven of nine basins and equaled the number excised for the other two basins. Freehand SPECT using a prototype SiPM-based gamma camera demonstrates high sensitivity for detection of SLNs in a preoperative setting. Camera fhSPECT is a potential means for efficiently obtaining real-time 3D activity distribution maps in applications such as image-guided percutaneous biopsy, and surgical SLN biopsy or radioguided tumor excision.

60 APPLIED LIFE SCIENCES↗

Intensity dependent spread theory

The Intensity Dependent Spread (IDS) procedure is an image-processing technique based on a model of the processing which occurs in the human visual system. IDS processing is relevant to many aspects of machine vision and image processing. For quantum limited images, it produces an ideal trade-off between spatial resolution and noise averaging, performs edge enhancement thus requiring only mean-crossing detection for the subsequent extraction of scene edges, and yields edge responses whose amplitudes are independent of scene illumination, depending only upon the ratio of the reflectance on the two sides of the edge. These properties suggest that the IDS process may provide significant bandwidth reduction while losing only minimal scene information when used as a preprocessor at or near the image plane.

Holben, Richard↗

High spatial resolution brain functional MRI using submillimeter balanced steady-state free precession acquisition

Purpose: One of the technical advantages of functional magnetic resonance imaging (fMRI) is its precise localization of changes from neuronal activities. While current practice of fMRI acquisition at voxel size around 3 × 3 × 3 mm{sup 3} achieves satisfactory results in studies of basic brain functions, higher spatial resolution is required in order to resolve finer cortical structures. This study investigated spatial resolution effects on brain fMRI experiments using balanced steady-state free precession (bSSFP) imaging with 0.37 mm{sup 3} voxel volume at 3.0 T. Methods: In fMRI experiments, full and unilateral visual field 5 Hz flashing checkerboard stimulations were given to healthy subjects. The bSSFP imaging experiments were performed at three different frequency offsets to widen the coverage, with functional activations in the primary visual cortex analyzed using the general linear model. Variations of the spatial resolution were achieved by removing outerk-space data components. Results: Results show that a reduction in voxel volume from 3.44 × 3.44 × 2 mm{sup 3} to 0.43 × 0.43 × 2 mm{sup 3} has resulted in an increase of the functional activation signals from (7.7 ± 1.7)% to (20.9 ± 2.0)% at 3.0 T, despite of the threefold SNR decreases in the original images, leading to nearly invariant functional contrast-to-noise ratios (fCNR) even at high spatial resolution. Activation signals aligning nicely with gray matter sulci at high spatial resolution would, on the other hand, have possibly been mistaken as noise at low spatial resolution. Conclusions: It is concluded that the bSSFP sequence is a plausible technique for fMRI investigations at submillimeter voxel widths without compromising fCNR. The reduction of partial volume averaging with nonactivated brain tissues to retain fCNR is uniquely suitable for high spatial resolution applications such as the resolving of columnar organization in the brain.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging beyond the surface region: Probing hidden materials via atomic force microscopy

Probing material properties at surfaces down to the single-particle scale of atoms and molecules has been achieved, but high-resolution subsurface imaging remains a nanometrology challenge due to electromagnetic and acoustic dispersion and diffraction. The atomically sharp probe used in scanning probe microscopy (SPM) has broken these limits at surfaces. Subsurface imaging is possible under certain physical, chemical, electrical, and thermal gradients present in the material. Of all the SPM techniques, atomic force microscopy has entertained unique opportunities for nondestructive and label-free measurements. Here, we explore the physics of the subsurface imaging problem and the emerging solutions that offer exceptional potential for visualization. We discuss materials science, electronics, biology, polymer and composite sciences, and emerging quantum sensing and quantum bio-imaging applications. The perspectives and prospects of subsurface techniques are presented to stimulate further work toward enabling noninvasive high spatial and spectral resolution investigation of materials including meta- and quantum materials.

74 ATOMIC AND MOLECULAR PHYSICS↗

MO-DE-207A-05: Dictionary Learning Based Reconstruction with Low-Rank Constraint for Low-Dose Spectral CT

Purpose: Spectral CT enabled by an energy-resolved photon-counting detector outperforms conventional CT in terms of material discrimination, contrast resolution, etc. One reconstruction method for spectral CT is to generate a color image from a reconstructed component in each energy channel. However, given the radiation dose, the number of photons in each channel is limited, which will result in strong noise in each channel and affect the final color reconstruction. Here we propose a novel dictionary learning method for spectral CT that combines dictionary-based sparse representation method and the patch based low-rank constraint to simultaneously improve the reconstruction in each channel and to address the inter-channel correlations to further improve the reconstruction. Methods: The proposed method has two important features: (1) guarantee of the patch based sparsity in each energy channel, which is the result of the dictionary based sparse representation constraint; (2) the explicit consideration of the correlations among different energy channels, which is realized by patch-by-patch nuclear norm-based low-rank constraint. For each channel, the dictionary consists of two sub-dictionaries. One is learned from the average of the images in all energy channels, and the other is learned from the average of the images in all energy channels except the current channel. With average operation to reduce noise, these two dictionaries can effectively preserve the structural details and get rid of artifacts caused by noise. Combining them together can express all structural information in current channel. Results: Dictionary learning based methods can obtain better results than FBP and the TV-based method. With low-rank constraint, the image quality can be further improved in the channel with more noise. The final color result by the proposed method has the best visual quality. Conclusion: The proposed method can effectively improve the image quality of low-dose spectral CT. This work is partially supported by the National Natural Science Foundation of China (No. 61302136), and the Natural Science Basic Research Plan in Shaanxi Province of China (No. 2014JQ8317).

60 APPLIED LIFE SCIENCES↗

SPECT/CT imaging of HER2 expression in colon cancer-bearing nude mice using 125I-Herceptin

Highlights: • {sup 125}I-Herceptin has a high affinity for HER2 in MC38 colon cancer cells. • SPECT imaging of HER2 in colon cancer using {sup 125}I-Herceptin is feasibility. • An effective, non-invasive and less costly in vivo detection method of HER2. An accurate assessment of HER2 status in patients with colorectal cancer is very important, because only the patients overexpressing HER2 can benefit most from the anti-HER2 targeted therapy. In this study, we investigated the feasibility of detecting HER2 expression in colon cancer by SPECT imaging using {sup 125}I-Herceptin, which showed high labeling rate, good in vitro stability and high binding specificity for HER2. HER2-positive mouse colon adenocarcinoma cell line (MC 38) was chosen as the colon caner cell model, and used for the establishment of colon cancer-bearing nude mice model. SPECT/CT imaging suggested that the tumors can be visualized at 12 h after the injection of {sup 125}I-Herceptin, and the uptake of tracer in tumors reached the peak at 24 h after injection, and can be attenuated significantly by pretreatment with an excess of nonlabeled Herceptin. These results indicates that {sup 125}I-Herceptin can be considered as an effective SPECT probe for the non-invasive detection of HER2 expression in colon cancer.

60 APPLIED LIFE SCIENCES↗

Electron microscopy analyses and electrical properties of the layered Bi{sub 2}WO{sub 6} phase

The bismuth tungstate Bi{sub 2}WO{sub 6} was synthesized using a classical coprecipitation method followed by a calcination process at different temperatures. The samples were characterized by X-ray diffraction, simultaneous thermogravimetry and differential thermal analysis (TGA/DTA), scanning and transmission electron microscopy (SEM, TEM) analyses. The Rietveld analysis and electron diffraction clearly confirmed the Pca2{sub 1} non centrosymmetric space group previously proposed for this phase. The layers Bi{sub 2}O{sub 2}{sup 2+} and WO{sub 4}{sup 2−} have been directly evidenced from the HRTEM images. The electrical properties of Bi{sub 2}WO{sub 6} compacted pellets systems were determined from electrical impedance spectrometry (EIS) and direct current (DC) analyses, under air and argon, between 350 and 700 °C. The direct current analyses showed that the conduction observed from EIS analyses was mainly ionic in this temperature range, with a small electronic contribution. Electrical change above the transition temperature of 660 °C is observed under air and argon atmospheres. The strong conductivity increase observed under argon is interpreted in terms of formation of additional oxygen vacancies coupled with electron conduction. - Graphical abstract: High resolution transmission electron microscopy: inverse fast Fourier transform giving the layered structure of the Bi{sub 2}WO{sub 6} phase, with a representation of the cell dimensions (b and c vectors). The Bi{sub 2}O{sub 2}{sup 2+} and WO{sub 4}{sup 2−} sandwiches are visible in the IFFT image. - Highlights: • Using transmission electron microscopy, we visualize the layered structure of Bi{sub 2}WO{sub 6}. • Electrical analyses under argon gas show some increase in conductivity. • The phase transition at 660 °C is evidenced from electrical modification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Segmentation precision of abdominal anatomy for MRI-based radiotherapy

The limited soft tissue visualization provided by computed tomography, the standard imaging modality for radiotherapy treatment planning and daily localization, has motivated studies on the use of magnetic resonance imaging (MRI) for better characterization of treatment sites, such as the prostate and head and neck. However, no studies have been conducted on MRI-based segmentation for the abdomen, a site that could greatly benefit from enhanced soft tissue targeting. We investigated the interobserver and intraobserver precision in segmentation of abdominal organs on MR images for treatment planning and localization. Manual segmentation of 8 abdominal organs was performed by 3 independent observers on MR images acquired from 14 healthy subjects. Observers repeated segmentation 4 separate times for each image set. Interobserver and intraobserver contouring precision was assessed by computing 3-dimensional overlap (Dice coefficient [DC]) and distance to agreement (Hausdorff distance [HD]) of segmented organs. The mean and standard deviation of intraobserver and interobserver DC and HD values were DC{sub intraobserver} = 0.89 ± 0.12, HD{sub intraobserver} = 3.6 mm ± 1.5, DC{sub interobserver} = 0.89 ± 0.15, and HD{sub interobserver} = 3.2 mm ± 1.4. Overall, metrics indicated good interobserver/intraobserver precision (mean DC > 0.7, mean HD < 4 mm). Results suggest that MRI offers good segmentation precision for abdominal sites. These findings support the utility of MRI for abdominal planning and localization, as emerging MRI technologies, techniques, and onboard imaging devices are beginning to enable MRI-based radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dynamics of unstably stratified free shear flows: an experimental investigation of coupled Kelvin–Helmholtz and Rayleigh–Taylor instability

The dynamics of the coupled Kelvin–Helmholtz (KH) and Rayleigh–Taylor (RT) instability (referred to as KHRT instability or KHRTI) is studied using statistically steady experiments performed in a multi-layer gas tunnel. Experiments are performed at four density ratios ranging in Atwood number $A_{t}$ from 0.035 to 0.159, with varying amounts of shear and $\unicode[STIX]{x0394}U/U$ ranging from 0 to 0.48, where $\unicode[STIX]{x0394}U$ is the speed difference between the two flow streams being investigated and $U$ is the mean velocity of these two streams. Three types of diagnostics – back-lit visualization, hot-wire anemometry and particle image velocimetry (PIV) – are employed to obtain the mixing widths, velocity field and density field. The flow is found to be governed by KH dynamics at early times and RT dynamics at late times. This transition from KH-instability-like to RT-instability-like behaviour is quantified using the Richardson number. Transitional Richardson number magnitudes obtained for the present KHRT flows are found to be in the range 0.17–0.56 similar to the critical Richardson numbers for stably stratified free shear flows. Comparing the evolution of density and velocity mixing widths, the density mixing layer is found to be approximately two times as thick as the velocity mixing layer. Scaling of velocity fluctuations is attempted using combinations of KH and RT scales. It is found that the proposed KHRT velocity scale, obtained using the combined mixing-layer growth equation, is appropriate for intermediate stages of the flow when both KH and RT dynamics are comparable. Probability density functions (p.d.f.s) for different fluctuating quantities are presented. Multiple peaks in p.d.f.s are qualitatively explained from the development of coherent KH roll-ups and their subsequent transition into turbulent pockets. The evolution of energy spectra indicates that density fluctuations start to show an inertial subrange from earlier times compared to velocity fluctuations. The spectra exhibit a slightly steeper slope than the Kolmogorov–Obukhov five-thirds law.

Mechanics↗

In situ nanoscale imaging of moiré superlattices in twisted van der Waals heterostructures

Abstract Direct visualization of nanometer-scale properties of moiré superlattices in van der Waals heterostructure devices is a critically needed diagnostic tool for study of the electronic and optical phenomena induced by the periodic variation of atomic structure in these complex systems. Conventional imaging methods are destructive and insensitive to the buried device geometries, preventing practical inspection. Here we report a versatile scanning probe microscopy employing infrared light for imaging moiré superlattices of twisted bilayers graphene encapsulated by hexagonal boron nitride. We map the pattern using the scattering dynamics of phonon polaritons launched in hexagonal boron nitride capping layers via its interaction with the buried moiré superlattices. We explore the origin of the double-line features imaged and show the mechanism of the underlying effective phase change of the phonon polariton reflectance at domain walls. The nano-imaging tool developed provides a non-destructive analytical approach to elucidate the complex physics of moiré engineered heterostructures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗