Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “home performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

A Scalable HPC Insider Threat Monitoring System

Cyber Equations, Inc. is reporting on the results of its DOE SBIR Phase I project for the development of a Scalable HPC Insider Threat Monitoring System. This final report to the Department of Energy for Task DE-FOA-0001618 covers the period from 02/21/2017 to 02/20/2018 and summarizes the larger research accomplishments, which can be divided in theoretical and laboratory experiments. One of the many challenges for the U.S. Department of Energy (DOE) is the support of the high-performance computing (HPC) centers while providing quality information services, strategic vision, leadership, technical expertise, and capabilities necessary to enable the DOE to deliver effective, efficient, economical, and secure HPC services. In order to realize a secure DOE laboratory enterprise, DOE facilities operations must counter a wide range of cyber insider threats, from unsophisticated adversaries up to advanced, nation state sponsored actors. The DOE laboratories also presents an enormous insider attack surface of an ever-growing number of computers, networks, and devices all running a myriad of software. In addition, the DOE laboratories are connected to a variety of external organizations which multiplies the possibility of insider threat. During this SBIR project Cyber Equations developed a strategic combination of supervised and unsupervised machine learning techniques to control scale and classify whether entities, such as hosts, actors, or documents, are showing suspicious insider behavior. We conducted experiments using real cyber data to show that changes in observable behavior (e.g., changes in outbound traffic patterns) are indicative of attacks executing (e.g., insiders exfiltrating data, bots calling home, or an attack spreading). The features and methods we use, have been used in the anomaly detection research and development community for a significant amount of time and robust implementations are openly available. K-Means clustering, Decision Trees, and Support Vector Machine based classifiers are readily available through the R language and open source H20 machine learning framework. The Cyber Equations approach is novel in its use of these classifiers combined with Hadoop based parallel processing technology. The five stages of processing used by CyberInsider improve scalability and reduce the high number of false positives normally associated with network anomaly detection. In summary, the Cyber Equations has successfully accomplished all of its Phase I tasks and demonstrated the feasibility of the Insider Threat Monitoring System.

97 MATHEMATICS AND COMPUTING↗

FEANICS: A Multi-User Facility For Conducting Solid Fuel Combustion Experiments On ISS

The Destiny Module on the International Space Station (ISS) will soon be home for the Fluids and Combustion Facility's (FCF) Combustion Integrated Rack (CIR), which is being developed at the NASA Glenn Research Center in Cleveland, Ohio. The CIR will be the platform for future microgravity combustion experiments. A multi-user mini-facility called FEANICS (Flow Enclosure Accommodating Novel Investigations in Combustion of Solids) will also be built at NASA Glenn. This mini-facility will be the primary means for conducting solid fuel combustion experiments in the CIR on ISS. The main focus of many of these solid combustion experiments will be to conduct basic and applied scientific investigations in fire-safety to support NASA's Bioastronautics Initiative. The FEANICS project team will work in conjunction with the CIR project team to develop upgradeable and reusable hardware to meet the science requirements of current and future investigators. Currently, there are six experiments that are candidates to use the FEANICS mini-facility. This paper will describe the capabilities of this mini-facility and the type of solid combustion testing and diagnostics that can be performed.

Frate, David T.↗

Physics-informed hybrid modeling methodology for building infiltration

Infiltration is responsible for one-third to one-half of the space conditioning load of a typical residential home, but the modeling of infiltration for building energy modeling is either represented by over-simplified equations or dependent on over-generalized rules of thumb. Here, this paper develops a physics-informed data-driven methodology for modeling infiltration using building-specific empirical measurements. The developed hybrid methodology combines machine-learning categorization and grey-box sub-modeling to improve the accuracy and generalization of commonly used grey-box infiltration models. The developed methodology excels at predicting infiltration by improving the ability to predict infiltration under unseen environmental conditions using machine learning algorithms with physical significance. In a case study conducted using the iUnit, a modular studio apartment experimental test facility located at the National Renewable Energy Laboratory, we use empirical airtightness measurements to fit an infiltration model using the developed methodology. We find that the developed methodology can improve the overall model accuracy by 43% and improve extrapolation by 38%, compared with the model based on the common grey-box infiltration equation. We also notice that the selected features can improve the performance of a pure machine-learning model, indicating that our methodology identifies the features with the most physical significance to infiltration modeling.

97 MATHEMATICS AND COMPUTING↗

Compressor Selection and Equipment Sizing for Cold Climate Heat Pumps

In order to limit heating capacity degradation at -25 C (-13 F) ambient to 25%, compared to the nominal rating point capacity at 8.3 C (47 F), an extensive array of design and sizing options were investigated, based on fundamental equipment system modeling and building energy simulation. Sixteen equipment design options were evaluated in one commercial building and one residential building, respectively in seven cities. The energy simulation results were compared to three baseline cases: 100% electric resistance heating, a 9.6 HSPF single-speed heat pump unit, and 90% AFUE gas heating system. The general recommendation is that variable-speed compressors and tandem compressors, sized such that their rated heating capacity at a low speed matching the building design cooling load, are able to achieve the capacity goal at low ambient temperatures by over-speeding, for example, a home with a 3.0 ton design cooling load, a tandem heat pump could meet this cooling load running a single compressor, while running both compressors to meet heating load at low ambient temperatures in a cold climate. Energy savings and electric resistance heat reductions vary with building types, energy codes and climate zones. Oversizing a heat pump can result in larger energy saving in a less energy efficient building and colder regions due to reducing electric resistance heating. However, in a more energy-efficient building or for buildings in warmer climates, one has to consider balance between reduction of resistance heat and addition of cyclic loss.

Building Energy Simulation↗

Home charging for all: Techno-economic and life cycle assessment of multi-unit dwelling electric vehicle charging hubs

Ubiquitous electric vehicle adoption can drastically reduce greenhouse gas emissions (GHG) but will require equitable home charging infrastructure for all residences. Unlike single-family homes, Multi-Unit Dwellings (MUD) currently lack market share and access to nearby charging infrastructure partly due to expensive capital costs for reluctant residential property-owners. Further, this work evaluates the levelized cost of charging (LCOC) for Battery Electric Vehicles (BEVs) at MUD community charging hubs through a techno-economic analysis (TEA) that leverages real-world charging data and costs. Three different MUD charging types are investigated for a baseline and optimistic case: 1.9-kW Level 1 (L1), 6.6-kW Level 2 (L2), and 50-kW Direct Current Fast Charging (DCFC) stations under three different ownership models: resident, utility, and private company. Results demonstrate L1 and L2 chargers to be less expensive than the gasoline equivalent across the United States. Further, utility and private company ownership models, which avoid initial costs for residential property owners, result in a large LCOC premium for L1 and moderate LCOC premium for L2 relative to the resident ownership model. In contrast, DCFC is shown to be expensive for baseline scenarios but economical for optimistic scenarios especially under private company ownership. This work also performs a cradle to grave (C2G) life cycle assessment (LCA) of an average passenger BEV and gasoline conventional vehicle (CV) using yearly (grid mix & vehicle parameters), hourly (grid mix), and state-level (grid mix) resolution. Results show BEVs to have lower GHG emissions (-86% to-10%) than gasoline CVs in the contiguous U.S. Next, the system boundary of the TEA is extended to the total cost of ownership (TCO) of BEVs. The TCO is then coupled with the C2G GHG emissions to calculate the cost of GHG emissions reduction. Ultimately, the cost of GHG emissions reduction from MUD BEVs relative to gasoline CVs is shown to be negative for every scenario except baseline DCFC, meaning MUD BEV charging infrastructure can be a cost-effective endeavor to reduce GHG emissions.

33 ADVANCED PROPULSION SYSTEMS↗

Detailed Evaluation of Electric Demand Load Shifting Potential of Heat Pump Water Heaters

Future utilities will emphasize home appliances to reduce greenhouse gas emissions while providing electric load shifting and demand profile management. Heat pump water heaters (HPWH) have demonstrated the ability to cut water heating energy by more than 65% compared with conventional electric resistance waters (ERWH). Laboratory research was conducted on the load shifting potential of grid-connected heat pump water heaters (HPWH), compared to ERWHs. Testing applied different CTA-2045 command designs. Highly-controlled laboratory experiments were conducted on one ERWH and four HPWHs, including a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load up above the tank setpoint. The prototype unit with the B-protocol increased tank temperature by 15oF (8.3C) under the advanced load up providing an increase of 1.8 kWh of storage for a 50-gallon (189 liter) tank. The prototype includes a built-in mixing valve to meet anti-scalding codes. With the load-shaping ability of CTA-2045-B, utilities might be able to store excess renewable energy in connected tanks when renewable wind and solar resource production is high. Tests were performed under baseline conditions (no load shift) and under several load-shifting schemes, including load up and advanced load up, ahead of shed commands. Grid-connected HPWHs reduced peak demand by as much as 0.5 kW, depending on tank volume, time of day, control scheme, and draw profile.

heat pump water heater, Demand flexibility, load s↗

Finding ways to reduce nuclear waste: searching for the unknown one step at a time

In my home country, Venezuela, research has been stagnant. Due to the political turmoil and the crisis, many educated people have left the country in search for a better life. This has caused a deficit in any technological and scientific advances, making Venezuela one of the first South American countries to have its rate of publications decline by 29% in 2013. Currently, Venezuela lacks the infrastructure and the means to keep up with the research progress as compared to other countries in South America, such as Brazil. Since coming to the United States (US), and currently working for a national laboratory, the active research environment endorses a wide range of careers and engineering programs that allow researchers to thrive at any given field. Researchers have access to funds and tools to succeed in developing materials for the future. There are 17 national laboratories in the US, and all of these have a different research focus/objective. As examples, Los Alamos National Laboratory and Sandia National Laboratory focus is on national homeland security, weapon science, radiation effects, among others. Argonne National Laboratory focuses on nuclear energy, energy storage, high performance computing, etc. At Idaho National Laboratory (INL) the research focuses on innovating nuclear energy and clean energy resources, critical infrastructure materials, along with fuel cycle solutions to manage, dispose and find ways to recycle current and future radiological waste. Compared to other national laboratories, INL focuses slightly more on applied processes and how nuclear energy can be innovated to next reactor design and technologies. The research being conducted at INL made me apply for a Seaborg distinguished postdoctoral position. For the position itself, the researcher must submit a proposal related to actinide chemistry on a research field area. In this position, 50% of my time will be focused on my own proposal. The proposal that I am working on is focused on the innovation of nuclear energy and fuel cycle recycling, which is why I was mainly interested on working at this national laboratory. To give a bit more context of what my proposal is about, a little bit of background is necessary: After the nuclear fuel (UO2) is used in a reactor, the fuel matrix is then characterized by various fission products (FP). Among these FP (including rare earth elements, alkali/alkaline earths, and actinides), many can potentially be recovered through nuclear reprocessing technologies. In pyroprocessing, the used nuclear fuel undergoes electrochemical dissolution into a molten chloride salt mixture in an electrorefiner. Initially, uranium is reduced onto an inert cathode by applied potentials. However, numerous remaining FPs accumulate in the melt and pose challenges for recovery by an inert electrode, particularly the rare earth elements (e.g., Nd, Gd, Pr, Sm) due to their multivalent oxidation states and tendencies toward side reactions, leading to their dissolution in the electrolyte. These recovery challenges result in inefficiencies and necessitate the continual discarding of the molten chloride salt, thereby generating additional waste. Furthermore, the presence of rare earth elements and other fission products in the molten salt electrolyte alters its physical and chemical properties, affecting both uranium recovery efficiency and the longevity of the molten chloride salt. To improve the recovery efficiency of the FP, specifically rare earth elements, I am investigating the fundamental interactions between rare earth elements in the molten chloride salt and their metallic form. The kinetic pathways and the chemical reactions of these elements will give insights on how the recovery efficiency can be improved. The interactions and speciation of these elements are being studied by spectro-electrochemistry at high temperature environments in quartz and other ceramic materials (e.g., alumina crucibles). Some of the challenges I am facing specifically relates the reactivity of some of these elements with different glass and crucible materials. Although my research focuses on fundamental science, it will benefit the applied process by generating new scientific knowledge and closing the gap for an efficient recycling of the waste: one step at a time.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Multi-Center Controlled Study of the Acute and Chronic Effects of Cooling Therapy for MS

To determine the acute and chronic effects of cooling therapy on patients with MS using objective functional performance measures and self-assessed measures of fatigue. Cooling demyelinated nerves can reduce conduction block, potentially improving symptoms of MS. Significant acute and chronic effects of cooling have not been demonstrated in a multi-center, controlled, blinded study using objective measures of neurologic function. Patients (N=84) with definite MS, mild to moderate disability (EDSS less than 6.0), and self-reported heat sensitivity were enrolled at 5 study sites. Acute effects of cooling were assessed by randomly assigning subjects to high-dose or low-dose cooling for one hour using an active cooling vest and cap (Life Enhancement Technologies, Santa Clara, CA). Settings were individualized to maintain the cooling garments at 55 F for the high-dose treatment and 70 F for the low-dose treatment. Both patients and examining investigators were blinded to treatment assignments. The MSFC and visual acuity/contrast sensitivity were assessed before and 30 minutes after treatment. The following week, subjects had an identical visit with the alternate cooling treatment. Chronic effects of cooling were assessed by randomly assigning the same subjects to unblinded daily home cooling or observation for 4 weeks. All subjects completed the Rochester Fatigue Diary (RFD) twice weekly and subjective measures of strength, cognition, and energy level daily. At the end of the period, subjects completed the Modified Fatigue Impact Scale (MFIS) and underwent another high-dose cooling session with assessment of the MSFC and vision. After a one-week washout period, subjects crossed over to the alternate 4-week treatment. Oral temperatures were reduced with both acute treatments (0.8 +/- .06 F, high and 0.5 +/- .06 F, low). While mean MSFC did not change significantly during individual cooling sessions, post hoc analysis pooling the 3 high-dose cooling sessions revealed an improvement in MSFC scores (acute phase 0.064 +/- 0.020, p = 0.0013; chronic phase 0.044 +/- 0.021, p = 0.0368) from before to after cooling. The change in MSFC scores during the acute cooling sessions was not related to the extent of change in oral temperatures. Both the RFD score and the MFIS indicate a significantly lower fatigue level during the cooling month compared to observation (RFD, 2.53 +/- 0.83,p = 0.0033; MFIS 7.63 +/- 1.56, p = 0.0001).

Luna, Bernadette↗

Sea Level Rise Impacts on Wastewater Treatment Systems Along the U.S. Coasts

As sea levels rise, coastal communities will experience more frequent and persistent nuisance flooding, and some low-lying areas may be permanently inundated. Critical components of lifeline infrastructure networks in these areas are also at risk of flooding, which could cause significant service disruptions that extend beyond the flooded zone. Thus, identifying critical infrastructure components that are exposed to sea level rise is an important first step in developing targeted investment in protective actions and enhancing the overall resilience of coastal communities. Wastewater treatment plants are typically located at low elevations near the coastline to minimize the cost of collecting consumed water and discharging treated effluent, which makes them particularly susceptible to coastal flooding. For this analysis, we used geographic information systems to assess the exposure of wastewater infrastructure to various sea level rise projections at the national level. We then estimated the number of people who would lose wastewater services, which could be more than five times as high as previous predictions of the number of people at risk of direct flooding due to sea level rise. We also performed a regional comparison of wastewater exposure to marine and groundwater flooding in the San Francisco Bay Area. Overall, this analysis highlights the widespread exposure of wastewater infrastructure in the United States and demonstrates that local disruptions to infrastructure networks may have far-ranging impacts on areas that do not experience direct flooding.Plain Language Summary Wastewater treatment plants are susceptible to flooding resulting from sea level rise. Previous estimates of wastewater exposure have only considered the impacts of marine flooding at the local or regional scale. In this analysis, we quantify the exposure to marine flooding across the coastal United States and then consider the relative impacts of marine and groundwater flooding at the regional scale in the San Francisco Bay Area. We also estimate the number of people who may lose access to wastewater services if no actions are taken to prevent flooding at wastewater treatment plants. We find that the number of people impacted by sea level rise due to loss of wastewater services could be five times as high as previous predictions of the number of people who experience direct flooding of their homes or property. We also find that groundwater flooding poses a significant threat to wastewater plants in the San Francisco Bay region.

54 ENVIRONMENTAL SCIENCES↗

Sleep during layovers of different lengths after long-haul flying across multiple time zones in different geographic directions

Introduction: Long-haul pilots experience high levels of fatigue and circadian disruption due to long work hours and trans-meridian travel. The aim of this study was to characterize sleep timing and duration during layovers of different lengths after crossing multiple time zones. Methods: All pilots flying long-haul operations from a single airline were eligible to participate. While following their normal work schedule within airline operations, pilots collected data for ~2 weeks including at least two long-haul rotations, with rest days and layovers. Participants wore an Actiwach (Phillips Respironics) throughout the entire study period and completed a sleep diary (at bedtime and upon waking up). Based on the data, we categorized layovers as follows: layover type 1: 34 h after crossing five time zones in westward direction; layover type 2: of 34 h, no time zone change; layover type 3: 55 h after crossing six time zones in eastward direction. Each flight left the home base at the same time of day (23:00) and the flight duration was between 10.5 and 12 hrs. We calculated descriptive statistics for each category. Results. Forty-four long-haul pilots participated in the study (5 female; mean age 44.25 ± 10.06 yrs; mean flight hours 9834.3 ± 5334.1 hrs). We found that for layover type 1, the mean sleep duration (h) per 24 h was 6.90 (±1.04), mean sleep efficiency (%) was 81.08 (±10.89) and mean Wake After Sleep Onset (WASO, min) was 33.23 (±20.42); for layover type 2, the mean sleep duration (h) per 24 h was 6.91 (±1.06), mean sleep efficiency (%) was 81.71 (±6.80), and mean WASO (min) was 30.10 (±11.00); for layover type 3, the mean sleep duration (h) was 7.07 (±1.32), mean sleep efficiency (%) was 83.93 (±6.04), and mean WAS (min) was 36.94 (±17.95). Conclusion: Our preliminary analyses showed that sleep duration and sleep efficiency were similar for the layovers of same length regardless time zone change. Additional analyses will be conducted to investigate sleep on additional layovers of different lengths and the effects of sleep obtained during layover on the performance and alertness on the return flights.

long-haul↗

An application of the theory of planned behaviour to study the influencing factors of participation in source separation of food waste

Highlights: ► Theory of planned behaviour (TPB) has been conducted to identify the influencing factors for participation in source separation of food waste using self administered questionnaires. ► The findings suggested several implications for the development and implementation of waste separation at home programme. ► The analysis indicates that the attitude towards waste separation is determined as the main predictors where this in turn could be a significant predictor of the repondent’s actual food waste separation behaviour. ► To date, none of similar have been reported elsewhere and this finding will be beneficial to local Authorities as indicator in designing campaigns to promote the use of waste separation programmes to reinforce the positive attitudes. - Abstract: Tremendous increases in biodegradable (food waste) generation significantly impact the local authorities, who are responsible to manage, treat and dispose of this waste. The process of separation of food waste at its generation source is identified as effective means in reducing the amount food waste sent to landfill and can be reused as feedstock to downstream treatment processes namely composting or anaerobic digestion. However, these efforts will only succeed with positive attitudes and highly participations rate by the public towards the scheme. Thus, the social survey (using questionnaires) to analyse public’s view and influencing factors towards participation in source separation of food waste in households based on the theory of planned behaviour technique (TPB) was performed in June and July 2011 among selected staff in Universiti Putra Malaysia, Serdang, Selangor. The survey demonstrates that the public has positive intention in participating provided the opportunities, facilities and knowledge on waste separation at source are adequately prepared by the respective local authorities. Furthermore, good moral values and situational factors such as storage convenience and collection times are also encouraged public’s involvement and consequently, the participations rate. The findings from this study may provide useful indicator to the waste management authorities in Malaysia in identifying mechanisms for future development and implementation of food waste source separation activities in household programmes and communication campaign which advocate the use of these programmes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Short-Term Monitoring Results for Advanced New Construction Test House—Roseville, California

A builder (K. Hovnanian® Homes®), design consultant, and trades collaborated to identify a systems integrated measures package for a 2,253-ft 2 slab-on-grade ranch house to achieve a modeled energy savings of 60% with respect to the Building America House Simulation Protocols, while minimizing construction costs and without requiring changes to the drawing that would impact local code or zoning approval. The key building improvements were applying R-10 insulation to the slab edge, increasing exterior wall cavity insulation from R-13 to R-15, and increasing attic insulation from R-30 to R-38. Also, the air handling unit was relocated from the attic to conditioned space, and ductwork was relocated along the attic floor with an insulated bulkhead built above it. Short-term testing results showed that duct air leakage was low due to short duct runs and the placement of ductwork in conditioned space. However, during commissioning, the lack of access for servicing the ductwork and dampers in the bulkhead area prevented retroactive balancing of individual branches, resulting in significant differences between specified and measured airflow values for some duct runs. Thermal imaging results performed on the house when operating in both heating and cooling modes validated historic stratification issues of ceiling supply registers with high supply air temperatures. Long-term monitoring results will be detailed in a future report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resource Assessment for Distributed Wind Energy: An Evaluation of Best-Practice Methods in the Continental US

Current wind resources within the United States (US) indicate a potential to profitably install nearly 1,400 gigawatts of distributed wind (DW) capacity. This amount is equivalent to over half of the United States’ current energy demand from electricity, making it enough to power millions of homes and businesses and replace countless fossil fuel-based generating plants. Despite the potential growth of DW in the US, deployments are presently hindered by a lack of confidence in resource estimation methods. One potential challenge is that smaller-scale turbines, with hub heights of 40 meters or less, are disproportionately impacted by obstacles such as buildings and vegetation. These obstacles may produce complex wake effects, best modeled with high-fidelity complex fluid dynamics (CFD) models that are too computationally expensive to use for routine siting and resource assessment. Thus, installers today make use of heuristics and simple equations to approximate the impact of obstacles while also leveraging long-term resource data from commercial or publicly available atmospheric models. This study evaluates these historical and commonly used methods alongside new lower-order obstacle models produced from CFD simulations and measurement-based bias correction. The preliminary results from this study show the importance of taking care in the choice and application of mesoscale atmospheric models and the significant value of bias correction using measurements from nearby meteorological towers. Detailed obstacle modeling provides only modest additional gains in performance and, in some cases, can add error, especially at sites where turbines have already been located to avoid obvious impact from upwind obstacles. These findings reinforce the importance of collecting in situ measurements and suggest that obstacle models may be better applied in practice to automated or computer-aided siting, rather than in economic wind resource assessments.

17 WIND ENERGY↗

Evaluation of clip localization for different kilovoltage imaging modalities as applied to partial breast irradiation setup

Surgical clip localization and image quality were evaluated for different types of kilovoltage cone beam imaging modalities as applied to partial breast irradiation (PBI) setup. These modalities included (i) clinically available radiographs and cone beam CT (CB-CT) and (ii) various alternative modalities based on partial/sparse/truncated CB-CT. An anthropomorphic torso-breast phantom with surgical clips was used for the imaging studies. The torso phantom had artificial lungs, and the attached breast phantom was a mammographic phantom with realistic shape and tissue inhomogeneities. Three types of clips of variable size were used in two orthogonal orientations to assess their in-/cross-plane characteristics for image-guided setup of the torso-breast phantom in supine position. All studies were performed with the Varian on-board imaging (OBI, Varian) system. CT reconstructions were calculated with the standard Feldkamp-Davis-Kress algorithm. First, the radiographs were studied for a wide range of viewing angles to characterize image quality for various types of body anatomy in the foreground/background of the clips. Next, image reconstruction quality was evaluated for partial/sparse/truncated CB-CT. Since these modalities led to reconstructions with strong artifacts due to insufficient input data, a knowledge-based CT reconstruction method was also tested. In this method, the input data to the reconstruction algorithm were modified by combining complementary data sets selected from the treatment and reference projections. Different partial/sparse/truncated CB-CT scan types were studied depending on the total arc angle, angular increment between the consequent views (CT projections), orientation of the arc center with respect to the imaged breast and chest wall, and imaging field size. The central angles of the viewing arcs were either tangential or orthogonal to the chest wall. Several offset positions of the phantom with respect to the reference position were studied. The acquired and reconstructed image data sets were analyzed using home-built software focusing on the ability to localize clips in 3D. Streaking and leakage reconstruction artifacts and spatial distortions of breast surface were analyzed as well. Advantages and disadvantages of each kilovoltage CB imaging modality as applied to partial breast setup evaluation based on clips are presented. Because clips were found to be difficult to recognize in radiographs, 3D reconstructions were preferred. Even though it was possible to localize clips with about {+-}1 mm accuracy based on reconstructions for short arcs of 40 deg. and incremental angle up to about 5 deg., identification of clips in such reconstructions is difficult. Reconstructions obtained for arcs of as low as 80 deg. and incremental angle of as high as 3 deg. were suggested for easier clip identification. For more severely undersampled data, iterative CB-CT reconstruction is recommended to decrease the artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Influence of Self-Reported Distractions on the Psychomotor Vigilance Task (PVT) in Laboratory and Field Environments

Introduction: The Psychomotor Vigilance Task (PVT) is a measure of vigilant attention that is commonly used in laboratory environments to assess the neurobehavioral impact of sleep loss and circadian misalignment. The PVT has been increasing in popularity for use in field environments; however, the potential for distraction is higher in the field compared to the lab. It is unclear how distractions experienced by individuals taking the PVT in the real world may influence reaction time metrics. We investigated the influence of self-reported distraction on PVT outcomes across laboratory and field environments. Methods: We examined PVT data from five studies including short (n=36 participants, 3799 PVTs) and long-haul (n=75 participants, 3283 PVTs) airline personnel, control center personnel (n=5 participants, 96 PVTs), and healthy individuals who participated in a study involving at-home and laboratory assessments (n=12 participants, 486 and 310 PVTs). Individuals in all of the studies were asked to complete the five-minute NASA PVT at least three times daily. Participants were asked to indicate the number of distractions they experienced immediately after each PVT. Mean PVT reaction time (RT) and number of distractions were computed for each study and overall. Results: Participants reported more distractions in field environments compared to the lab (short-haul=1.29 +/- 1.48, long-haul=0.66 +/- 1.07, control-center=1.20 +/- 1.37, at-home=0.86 +/- 1.36, laboratory=0.46 +/- 1.07) Across all studies, we found that PVT RT slowed as self-reported distractions increased (all studies combined: 0 distractions=PVT RT 274.4ms; 1=284.6ms; 2=302.9ms; 3=321.2ms; >4=409.3ms). These findings were similar for healthy participants completing PVTs at home (0 distractions=287.1ms; 1=309.9ms; 2=328.3ms; 3=369.8ms; >4=385.1ms) but were less consistent during in-lab assessments (0 distractions=278.7ms; 1=316.2ms; 2=396.2ms; 3=370.4ms; >4=354.4ms). These findings were similar for other PVT outcomes. Conclusion: Participants reported more distractions in field environments compared to the laboratory. Our findings suggest that the number of distractions that individuals report experiencing while taking a PVT increases the reaction time registered by the device. Researchers should collect information about distractions during the PVT and should be aware that distractions may influence the recorded PVT reaction time.

behavior↗

The Mercury Laser System-A scaleable average-power laser for fusion and beyond

Nestled in a valley between the whitecaps of the Pacific and the snowcapped crests of the Sierra Nevada, Lawrence Livermore National Laboratory (LLNL) is home to the nearly complete National Ignition Facility (NIF). The purpose of NIF is to create a miniature star-on demand. An enormous amount of laser light energy (1.8 MJ in a pulse that is 20 ns in duration) will be focused into a small gold cylinder approximately the size of a pencil eraser. Centered in the gold cylinder (or hohlraum) will be a nearly perfect sphere filled with a complex mixture of hydrogen gas isotopes that is similar to the atmosphere of our Sun. During experiments, the laser light will hit the inside of the gold cylinder, heating the metal until it emits X-rays (similar to how your electric stove coil emits visible red light when heated). The X-rays will be used to compress the hydrogen-like gas with such pressure that the gas atoms will combine or 'fuse' together, producing the next heavier element (helium) and releasing energy in the form of energetic particles. 2010 will mark the first credible attempt at this world-changing event: the achievement of fusion energy 'break-even' on Earth using NIF, the world's largest laser! NIF is anticipated to eventually perform this immense technological accomplishment once per week, with the capability of firing up to six shots per day - eliminating the need for continued underground testing of our nation's nuclear stockpile, in addition to opening up new realms of science. But what about the day after NIF achieves ignition? Although NIF will achieve fusion energy break-even and gain, the facility is not designed to harness the enormous potential of fusion for energy generation. A fusion power plant, as opposed to a world-class engineering research facility, would require that the laser deliver drive pulses nearly 100,000 times more frequently - a rate closer to 10 shots per second as opposed to several shots per day.

42 ENGINEERING↗

A Cooperative Multi-Agent Deep Reinforcement Learning Framework for Real-Time Residential Load Scheduling

Internet-of-Things (IoT) enabled monitoring and control capabilities are enabling increasing numbers of household users with controllable loads to actively participate in smart grid energy management. Realizing an efficient real-time energy management system that takes advantage of these developments requires novel techniques for managing the increased complexity of the control action space in resolving multiple challenges such as the uncertainty in energy prices and renewable energy output along with the need to satisy physical grid constraints such as transformer capacity. Addressing these challenges, we develop a multi-household energy management framework for residential units connected to the same transformer and containing DERs such as PV, ESS and controllable loads. The goal of our framework is to schedule controllable household appliances and ESS such that the cost of procuring electricity from the utility over a horizon is minimized while physical grid constraints are satisfied at each scheduling step. Traditional energy management frameworks either perform global optimization to satisfy grid constraints but suffer from high computational complexity (for example Integer Program, Mixed Integer Programming frameworks and centralized reinforcement learning) or perform decentralized real-time energy management without satisfying global grid constraints (for example multi-agent reinforcement learning with no cooperation). In contrast, we propose a cooperative multiagent reinforcement learning (MARL) framework that i) operates in real-time, and ii) performs explicit collaboration to satisfy global grid constraints. The novelty in our framework is two fold. Firstly, our framework trains multiple independent learners (IL) for each household in parallel using historical data and performs real-time inferencing of control actions using the most recent system state. Secondly, our framework contains a low complexity knapsack based cooperation agent which combines the outputs of ILs to minimize cost while satisfying grid constraints. Simulation results show that our cooperative MARL approach achieves significant cost improvement over centralized reinforcement learning and day-ahead planning baselines. Moreover, our approach strictly satisfies physical constraints with no apriori knowledge of system dynamics while the baseline approaches have occasional violations. We also measure the training and inference time by ranging the number of households from 1 to 25. Results show that our cooperative MARL approach scales best among various approaches.

14 SOLAR ENERGY↗

The Walls Come Tumbling Down: Decontamination and Demolition of 29 Manhattan Project and Cold War-Era Buildings and Structures at Los Alamos National Laboratory-12301

When the nation's top scientists and military leaders converged on Los Alamos, New Mexico in the 1943, to work on the Manhattan Project, the facilities they used to conduct their top-secret work were quickly constructed and located in the middle of what eventually became the Los Alamos town site. After one of these early facilities caught on fire, it seemed wise to build labs and production facilities farther away from the homes of the town's residents. They chose to build facilities on what was then known as Delta Prime (DP) Mesa and called it Technical Area 21, or TA-21. With wartime urgency, a number of buildings were built at TA-21, some in as little as a few months. Before long, DP Mesa was populated with several nondescript metal and cinder-block buildings, including what became, immediately following the war, the world's first plutonium production facility. TA-21 also housed labs that used hazardous chemicals and analyzed americium, tritium and plutonium. TA-21 was a bustling center of research and production for the next several decades. Additional buildings were built there in the 1960's, but by the 1990's many of them had reached the end of their service lives. Labs and offices were moved to newer, more modern buildings. When Los Alamos National Laboratory received $212 million in funding from the American Recovery and Reinvestment Act in July 2009 for environmental cleanup projects, about $73 million of the funds were earmarked to decontaminate and demolish 21 of the old buildings at TA-21. Although some D and D of TA-21 buildings was performed in the 1990's, many of the facilities at DP Site remained relatively untouched for nearly three decades following their final operational use. In 2006, there were over three dozen buildings or structures on the mesa to be removed so that soil cleanup could be completed (and the land made available for transfer and reuse). The total footprint of buildings across the mesa was approximately 18,580 m{sup 2} (200,000 ft{sup 2}). The initially approved baseline for the ARRA D and D Project was to remove 22 buildings and structures that included approximately 14,680 m{sup 2} (158,000 ft{sup 2}) of footprint. By employing efficiencies during subcontracting, demolition, and waste segregation, the savings allowed an additional 1,580 m{sup 2} (17,000 ft{sup 2}) of footprint to be removed using ARRA funds. Additionally, the lessons learned from this experience were used to apply NNSA funding to the removal of six additional non-contaminated buildings and structures. In the end, 29 buildings and structures, including stacks, cooling towers and tanks, were removed from the mesa. The entire DP East area was cleared of buildings and sub-grade structures and the soils cleaned to residential standards. The total footprint reduction at TA-21 as a result of this effort was in excess of 17,650 m{sup 2} (190,000 ft{sup 2}). The use of a Laboratory self-performance team to start demolition of non-contaminated structures resulted in steady work performance early in the project while subcontracts were being put in place to perform more complicated abatement and contaminated demolition activities. Most importantly, there were no serious worker injuries and the minor injuries recorded were those common to construction type activities. Extensive monitoring along the site boundary demonstrated that no hazardous chemicals or radioactive contamination were released and radiological dose to the public was negligible. The ARRA demolition activities were completed six months in advance of the deadline for employing ARRA funds. Additionally, over 17,585 m{sup 3} (23,000 yds{sup 3}) of building demolition debris was safely removed from DP Mesa. All of the major buildings have been removed, unencumbered access to the SWMUs that are required to be cleaned up by the Consent Order with the state of New Mexico, has been achieved, and a significant portion of the mesa has been prepared to support a process that will eventually transfer this land from federal government control for further use. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗