Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Atomic Molybdenum for Synthesis of Ammonia with 50% Faradic Efficiency

The electrochemical dinitrogen (N 2 ) reduction reaction (NRR) under ambient conditions has gained significant interest as an environmentally friendly alternative to the traditional Haber–Bosch process for the synthesis of ammonia (NH 3 ). However, up to now, most of the reported NRR electrocatalysts with satisfactory catalytic activities have been hindered by the large overpotential in N 2 activation. The preparation of highly efficient Mo-based NRR electrocatalyst in acidic electrolytes under ambient conditions is demonstrated here, consisting of stabilized single Mo atoms anchored on holey nitrogen-doped graphene synthesized through a convenient potassium-salt-assisted activation method. At -0.05 V versus a reversible hydrogen electrode (RHE), an electrode consisting of the resultant electrocatalyst immobilized on carbon fiber paper can attain an exceptional Faradaic efficiency of 50.2% and a NH3 yield rate of 3.6 µg h -1 mg cat -1 with low overpotentials. Density functional theory calculations further unveil that compared to the original graphene without holes, the edge coordinated Mo atoms and the existence of vacancies on holey graphene lower the overpotential of N 2 reduction, thereby promoting the NRR catalytic activity. Finally, this work could provide new guidelines for future designs in single-atom catalysis that would be beneficial to ambient N 2 fixation, and replacement of classical synthesis processes that are very energy-intensive.

36 MATERIALS SCIENCE↗

Fundamental Understanding of “Fresh” Lithium Nucleation and Growth in Sulfide-Based Anode-Free Solid-State Batteries: Effects of Substrate, Current Density, and Li + Supply

Understanding the electrochemical extraction and deposition of lithium (Li) from cathode is crucial for advancing anode-free solid-state batteries (AFSSBs). Herein, cryo-transmission electron microscopy (cryo-TEM) and electrochemical studies are employed to investigate how current collector surface properties, current densities, and cathode loadings influence the morphology of fresh electrochemically deposited Li and the electrochemical performance in sulfide-based AFSSBs. Cryo-TEM reveals that Cu current collectors induce irregular, dendritic Li deposits due to their lithiophobic nature and reactivity with Li 5.4 PS 4.4 Cl 1.6 (LPSC), while Ni and Au facilitate more uniform, planar-like Li growth. The morphology of the deposited Li also depends on current density: higher rates produce smaller, porous particles versus larger, denser deposits at lower rates. Importantly, for the first time, we discovered that low cathode loadings lead to poor cycling stability due to insufficient Li + supply for complete anode coverage, contrary to conventional solid-state batteries with preloaded Li metal anodes. This finding establishes a design principle where adequate cathode Li + reservoirs are essential for anode interface stability in AFSSBs. Overall, this work elucidates the interplayed effect of current collectors, current densities, and cathode loadings on Li morphology and cycle stability, offering fundamental insights into cathode-derived Li behavior and practical guidelines for optimizing AFSSBs performance through nucleation control and interface engineering.

25 ENERGY STORAGE↗

Strain Field Around Individual Dislocations Controls Failure

Understanding material failure on a fundamental level is a key aspect in the design of robust structural materials, especially for metals and alloys capable to undergo plastic deformation. In the last decade, significant progress is made in quantifying the stresses associated with failure in both experiments and simulations. Nonetheless, the processes occurring on the most essential level of individual dislocations that govern semi-brittle and ductile fracture are still experimentally not accessible, limiting the failure prediction capabilities. Therefore, in the present work, a one-of-a-kind nanoscale fracture experiment is conducted on a single crystalline Cr bending beam in situ in the transmission electron microscope and for the first time quantify the transient strains around individual dislocations, as well as of the whole dislocation network during crack opening. The results reveal the importance of both pre-existing and newly emitted dislocations for crack-tip shielding via their intrinsic strain field and provide guidelines to design more damage tolerant materials.

36 MATERIALS SCIENCE↗

In Situ Structure Characterization in Slot-Die-Printed All-Polymer Solar Cells with Efficiency Over 9%

Herein, high-performance printed all-polymer solar cells (all-PSCs) based on a bulk-heterojunction (BHJ) blend film are demonstrated using PTzBI as the donor and N2200 as the acceptor. A slot-die process is used to prepare the BHJ blend, which is a cost-effective, high-throughput approach to achieve large-area photovoltaic devices. The real-time crystallization of polymers in the film drying process is investigated by in situ grazing incidence wide-angle X-ray scattering characterization. Printing is found to significantly improve the crystallinity of the polymer blend in comparison with spin coating. Moreover, printing with 1,8-diiodooctane as the solvent additive enhances the polymer aggregation and crystallization during solvent evaporation, eventually leading to multi-length-scale phase separation, with PTzBI-rich domains in-between the N2200 crystalline fibers. This unique morphology achieved by printing fabrication results in an impressively high power conversion efficiency of 9.10%, which is the highest efficiency reported for printed all-PSCs. Finally, these findings provide important guidelines for controlling film drying dynamics for processing all-PSCs.

14 SOLAR ENERGY↗

Morphology and Dynamics of Bottlebrush Polymers

This thesis makes significant advances to the understanding of bottlebrush polymers. While bottlebrushes have received much attention due to the recent discovery of their unprecedented properties, including supersoftness, ultra-low viscosity, and hyperelasticity, this thesis is the first fundamental investigation at the molecular level that comprises structure and dynamics. Neutron scattering experiments, detailed within, reveal spherical or cylindrical shapes, instead of a random coil conformation. Another highlight is the analysis of the fast dynamics at the sub nm-length scale. The combination of three neutron spectrometers and the development of a new analysis technique enabled the calculation of the mean-square displacement over seven orders of magnitude in time scale. This unprecedented result can be applied to a broad class of samples, including polymers and other materials. The thesis is accessible to scientists from other fields, provides the reader with easily understandable guidelines for applying this analysis to other materials, and has the potential to make a significant impact on the analysis of neutron scattering data.

36 MATERIALS SCIENCE↗

A Survey on Sustainable Software Ecosystems to Support Experimental and Observational Science at Oak Ridge National Laboratory

In the search for a sustainable approach for software ecosystems that supports experimental and observational science (EOS) across Oak Ridge National Laboratory (ORNL), we conducted a survey to understand the current and future landscape of EOS software and data. This paper describes the survey design we used to identify significant areas of interest, gaps, and potential opportunities, followed by a discussion on the obtained responses. The survey formulates questions about project demographics, technical approach, and skills required for the present and the next five years. The study was conducted among 38 ORNL participants between June and July of 2021 and followed the required guidelines for human subjects training. We plan to use the collected information to help guide a vision for sustainable, community-based, and reusable scientific software ecosystems that need to adapt effectively to: i) the evolving landscape of heterogeneous hardware in the next generation of instruments and computing (e.g. edge, distributed, accelerators), and ii) data management requirements for data-driven science using artificial intelligence.

Bernholdt, David↗

Challenges for monitoring and data analytics in a leadership public data repository

The availability and disposition of data has assumed increasing importance in large-scale computational science. Data repositories are evolving to meet new classes of requirements: compliance with government access guidelines, support for reproducibility of experimental results, and long-term availability of data products. The Constellation public data repository at the Oak Ridge Leadership Computing Facility faces these issues while being situated in one of the most productive data centers in the world. While monitoring and operational data analysis are ingrained in the operation of the OLCF’s large-scale high performance computing platforms, data repositories do not have this history of support. Problems faced by Constellation range from data size (over 7 petabytes in current holdings) to analytic complexity (detailed curation is both absolutely necessary for many data sets and absolutely impossible for humans to accomplish in any practical manner) to deployment environment (OLCF storage resources are oriented toward the needs of the compute platforms). In this paper we describe some of the challenges for collecting monitoring and analytic data from a leadership public data repository. We also discuss various strategies we are pursuing in order to address these challenges, from manual data collection to plans for introducing machine learning-based curatorial techniques.

Widener, Patrick [ORNL] (ORCID:0000000258820816)↗

Frequency Domain Reflectometry Modeling and Measurement for Nondestructive Evaluation of Nuclear Power Plant Cables

Cable insulation polymers are among the more susceptible materials to age-related degradation within a nuclear power plant. This is recognized by both regulators and utilities, so all plants have developed cable aging management programs to detect damage before critical component failure in compliance with regulatory guidelines. Although a wide range of tools are available to evaluate cables and cable systems, cable aging management programs vary in how condition monitoring and NDE is conducted as utilities search for the most reliable and cost-effective ways to assess cable system condition. Frequency domain reflectometry (FDR) is emerging as one valuable tool to locate and assess damaged portions of a cable system with minimal cost and only requires access in most cases to one of the cable terminal ends. This work examines a physics-based model of a cable system and relates it to FDR measurements for a better understanding of specific damage influences on defect detectability.

cable↗

Applications of KPFM-Based Approaches for Surface Potential and Electrochemical Measurements in Liquid

Kelvin probe force microscopy (KPFM) has been widely used to map nanoscale surface potentials of materials in ambient and ultra-high vacuum environments. However, to study and ultimately understand charge-related processes, e.g., in biological systems or to further improve energy storage devices such as electrochemical batteries, nanoscale surface potential measurements in liquid environments are required. Here, we describe the various implementations of KPFM-based approaches for measuring surface potentials in liquid environments. We provide practical guidelines for surface potential measurements and describe what other information can be obtained. Finally, we discuss potential applications and limitations of existing approaches and present possible solutions for the successful implementation of liquid KPFM.

Collins, Liam F.↗

Manufacturing and stiffness constraints for topology optimized periodic structures

Topology optimization (TO) is commonly applied to design the unit cells of periodic structures. For example, metamaterials, lattice structures, phononic crystals (PhC), and photonic crystals (PC) have all been previously designed via TO. Unfortunately, the optimal structures for certain design objectives, e.g., bandgaps, are often impossible to manufacture as they have disconnected regions or “islands” of solid material (ISM) that are not self-supporting. Additionally, designs with enclosed void space (EVS) are problematic for additive manufacturing (AM) since support material or pre-sintered powder cannot be removed after manufacturing. We present a series of constraints that may be incorporated into any TO framework to ensure structures are self-supporting without enclosed voids. Additionally, we employ homogenization-based constraints that allow the designer to tune the elastic stiffness and isotropy of the optimized design. The proposed constraints are evaluated on example microstructures and utilized in a simple optimization test problem to highlight their abilities and limitations so that guidelines for appropriate combinations of constraints may be proposed. Effective constraint combinations are demonstrated on the design of 3D photonic crystals for maximum bandgap subject to manufacturing and stiffness constraints.

42 ENGINEERING↗

Mass Spectrometry Imaging of Biological Tissue: An Approach for Multicenter Studies

Mass spectrometry imaging has become a popular tool for probing the chemical complexity of biological surfaces. This led to the development of a wide range of instrumentation and preparation protocols. It is thus desirable to evaluate and compare the data output from different methodologies and mass spectrometers. Here, we present an approach for the comparison of mass spectrometry imaging data from different laboratories (often referred to as multicenter studies). This is exemplified by the analysis of mouse brain sections in five laboratories in Europe and the USA. The instrumentation includes matrix-assisted laser desorption/ionization (MALDI)-time-of-flight (TOF), MALDI-QTOF, MALDIFourier transform ion cyclotron resonance (FTICR), atmospheric-pressure (AP)-MALDI-Orbitrap, and cluster TOF-secondary ion mass spectrometry (SIMS). Experimental parameters such as measurement speed, imaging bin width, and mass spectrometric parameters are discussed. All datasets were converted to the standard data format imzML and displayed in a common open-source software with identical parameters for visualization, which facilitates direct comparison of MS images. The imzML conversion also allowed exchange of fully functional MS imaging datasets between the different laboratories. The experiments ranged from overview measurements of the full mouse brain to detailed analysis of smaller features (depending on spatial resolution settings), but common histological features such as the corpus callosum were visible in all measurements. High spatial resolution measurements of AP-MALDI-Orbitrap and TOF-SIMS showed comparable structures in the low-micrometer range. We discuss general considerations for planning and performing multicenter studies in mass spectrometry imaging. This includes details on the selection, distribution, and preparation of tissue samples as well as on data handling. Such multicenter studies in combination with ongoing activities for reporting guidelines, a common data format (imzML) and a public data repository can contribute to more reliability and transparency of MS imaging studies.

Environmental Molecular Sciences Laboratory↗

Impact of femoral neck and lumbar spine BMD discordances on FRAX probabilities in women: A meta-analysis of international cohorts

There are occasional marked discordances in BMD T-scores at the lumbar spine (LS) and femoral neck (FN). We investigated whether such discordances could contribute independently to fracture prediction using FRAX. In this paper, we studied 21,158 women, average age 63 years, from 10 prospective cohorts with baseline FRAX variables as well as FN and LS BMD. Incident fractures were collected by self-report and/or radiographic reports. Extended Poisson regression examined the relationship between differences in LS and FN T-scores (ΔLS–FN) and fracture risk, adjusted for age, time since baseline and other factors including FRAX 10-year probability for major osteoporotic fracture calculated using FN BMD. To examine the effect of an adjustment for ΔLS–FN on reclassification, women were separated into risk categories by their FRAX major fracture probability. High risk was classified using two approaches: being above the National Osteoporosis Guideline Group intervention threshold or, separately, being in the highest third of each cohort. The absolute ΔLS–FN was greater than 2 SD for 2.5 % of women and between 1 and 2 SD for 21 %. ΔLS–FN was associated with a significant risk of fracture adjusted for baseline FRAX (HR per SD change = 1.09; 95 % CI = 1.04–1.15). In reclassification analyses, only 2.3–3.2 % of the women moved to a higher or lower risk category when using FRAX with ΔLS–FN compared with FN-derived FRAX alone. Adjustment of estimated fracture risk for a large LS/FN discrepancy (>2SD) impacts to a large extent on only a relatively small number of individuals. More moderate (1–2SD) discordances in FN and LS T-scores have a small impact on FRAX probabilities. Finally, this might still improve clinical decision-making, particularly in women with probabilities close to an intervention threshold.

60 APPLIED LIFE SCIENCES↗

Computed tomographic perfusion with 160-mm coverage: comparative analysis of hepatocellular carcinoma treated by two transarterial chemoembolization courses relative to magnetic resonance imaging findings

Purpose: The aim of this study was to assess hepatocellular carcinoma (HCC) response with CT perfusion parameters before and after two transarterial chemo embolization (TACE) courses compared with MRI, and to search for predictive factors of response. Methods: 37 lesions (19 patients) were included between October 2015 and September 2017, based on the Barcelona Clinic Liver Cancer guidelines. CT perfusion with 160-mm coverage and MRI were performed before and after the first TACE course, and after the second TACE course. Quantitative perfusion parameters were compared to the response assessed with MRI using mRECIST criteria, defining response groups: complete response (CR), partial response (PR), no response (NR), response (including CR and PR), no complete response (NCR, including PR and NR). Results: Pre-TACE blood flow (BF) and hepatic arterial blood flow (HABF) were significantly higher in lesions with post-TACE 1 CR than in those with NCR (BF: 118.8 vs. 76.3 mL/100 g/min, p = 0.0231; HABF: 76 vs. 44.2 mL/100 g/min, p = 0.0112). Pre-TACE time to peak (TTP) and mean transit time (MTT) were significantly lower in lesions with post-TACE 2 response than in those with NR (TTP: 31.5 vs. 46.1 s, p = 0.0313; MTT: 15.8 vs. 22.8 s, p = 0.0204). Post-TACE 1 and post-TACE 2 perfusion parameters did not exhibit any statistically significant differences relative to MRI response. Conclusion: Our study did not find, after a first TACE course, perfusion parameters associated with a response to a second TACE course. However, baseline perfusion parameters analysis could lead to better therapeutic management of HCC by targeting lesions likely to respond well to TACE courses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pearls and pitfalls of response evaluation criteria in solid tumors (RECIST) v1.1 non-target lesion assessment

Oncologic imaging is an important facet of abdominal imaging that radiologists encounter nearly every day. Many oncology clinical trials utilize response evaluation criteria in solid tumors (RECIST) version 1.1 which divides tumor sites into target and non-target lesions. Although RECIST v1.1 provides clear instructions regarding the use of imaging in clinical trials, errors in response assessment still occur using these criteria. This is especially true of response assessment with regards to non-target lesions which involve rules which are less well-defined and somewhat subjective. This pictorial essay will review RECIST v1.1 guidelines and common non-target lesion errors which can occur at baseline and follow-up response assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rectal cancer MR staging: pearls and pitfalls at baseline examination

In recent years, rectal MRI has become a central diagnostic tool in rectal cancer staging. Indeed, rectal MR has the ability to accurately evaluate a number of important findings that may impact patient management, including distance of the tumor to the mesorectal fascia, presence of extramural vascular invasion (EMVI), presence of lymph nodes, and involvement of the peritoneum/anterior peritoneal reflection. Many of these findings are difficult to assess in nonexpert hands. In this review, we present a practical approach for radiologists to provide high-quality interpretations at initial baseline exams, based on recent guidelines from the Society of Abdominal Radiology, Rectal and Anal Cancer Disease Focused Panel. Practical pearls and pitfalls are discussed, focusing on optimization of technique including, patient preparation and protocol recommendations, interpretation, and essentials of reporting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of a machine learning-based decision model to help clinicians decide the extent of lymphadenectomy (D1 vs. D2) in gastric cancer before surgical resection

Background: Controversy still exists on the optimal surgical resection for potentially curable gastric cancer (GC). Use of radiologic evaluation and machine learning algorithms might predict extent of lymphadenectomy to limit unnecessary surgical treatment. We purposed to design a machine learning-based clinical decision-support model for predicting extent of lymphadenectomy (D1 vs. D2) in local advanced GC. Methods: Clinicoradiologic features available from routine clinical assignments in 557 patients with GCs were retrospectively interpreted by an expert panel blinded to all histopathologic information. All patients underwent surgery using standard D2 resection. Decision models were developed with a logistic regression (LR), support vector machine (SVM) and auto-encoder (AE) algorithm in 371 training and tested in 186 test data, respectively. The primary end point was to measure diagnostic performance of decision model and a Japanese gastric cancer treatment guideline version 4th (JPN 4th) criteria for discriminate D1 (pT1 + pN0) versus D2 (≥ pT1 + ≥ pN1) lymphadenectomy. Results: The decision model with AE analysis produced highest area under ROC curve (train: 0.965, 95% confidence interval (CI) 0.948–0.978; test: 0.946, 95% CI 0.925–0.978), followed by SVM (train: 0.925, 95% CI 0.902–0.944; test: 0.942, 95% CI 0.922–0.973) and LR (train: 0.886, 95% CI 0.858–0.910; test: 0.891, 95% CI 0.891–0.952). By this improvement, overtreatment was reduced from 21.7% (121/557) by treat-all pattern, to 15.1% (84/557) by JPN 4th criteria, and to 0.7–0.9% (4–5/557) by the new approach. Conclusions: The decision model with machine learning analysis demonstrates high accuracy for identifying patients who are candidates for D1 versus D2 resection. Its approximate 14–20% improvements in overtreatment compared to treat-all pattern and JPN 4th criteria potentially increase the number of patients with local advanced GCs who can safely avoid unnecessary lymphadenectomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗