100 TeV pp collisions, SM type, JETPHOX generator: tev100pp_gamma_pt1tev_jetphox
Inclusive gamma at NLO QCD for pT(gamma) above 1 TeV. CT10 NLO +52 PDF errors
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Inclusive gamma at NLO QCD for pT(gamma) above 1 TeV. CT10 NLO +52 PDF errors
A 50 Mbps direct detection optical communication system for use in an intersatellite link was constructed with an AlGaAs laser diode transmitter and a silicon avalanche photodiode photodetector. The system used a Q = 4 PPM format. The receiver consisted of a maximum likelihood PPM detector and a timing recovery subsystem. The PPM slot clock was recovered at the receiver by using a transition detector followed by a PLL. The PPM word clock was recovered by using a second PLL whose input was derived from the presence of back-to-back PPM pulses contained in the received random PPM pulse sequences. The system achieved a bit error rate of 0.000001 at less than 50 detected signal photons/information bit. The receiver was capable of acquiring and maintaining slot and word synchronization for received signal levels greater than 20 photons/information bit, at which the receiver bit error rate was about 0.01.
In this work, we test the efficacy of excited state mean field theory and its excited-state-specific perturbation theory on the prediction of K-edge positions and x-ray peak separations. We find that the mean field theory is surprisingly accurate, even though it contains no accounting of differential electron correlation effects. In the perturbation theory, we test multiple core-valence separation schemes and find that, with the mean field theory already so accurate, electron-counting biases in one popular separation scheme become a dominant error when predicting K-edges. Happily, these appear to be relatively easy to correct for, leading to a perturbation theory for K-edge positions that is lower scaling and more accurate than coupled cluster theory and competitive in accuracy with recent high-accuracy results from restricted open-shell Kohn-Sham theory. For peak separations, our preliminary data show excited state mean field theory to be exceptionally accurate, but more extensive testing will be needed to see how it and its perturbation theory compare to coupled cluster peak separations more broadly.
In this article, proton radiography is a central diagnostic technique for measuring electromagnetic (EM) fields in high-energy-density, laser-produced plasmas. In this technique, protons traverse the plasma where they accumulate small EM deflections which lead to variations in the proton fluence pattern on a detector. Path-integrated EM fields can then be extracted from the fluence image through an inversion process. In this work, experiments of laser-driven foils were conducted on the OMEGA laser and magnetic field reconstructions were performed using both “fluence-based” techniques and high-fidelity “mesh-based” methods. We implement nonzero boundary conditions into the inversion and show their importance by comparing against mesh measurements. Good agreement between the methods is found only when nonzero boundary conditions are used. We also introduce an approach to determine the unperturbed proton source profile, which is a required input in fluence reconstruction algorithms. In this approach, a fluence inversion is embedded inside of a mesh region, which provides overconstrained magnetic boundary conditions. A source profile is then iteratively optimized to satisfy the boundary information. This method substantially enhances the accuracy in recovering EM fields. Lastly, we propose a scheme to quantify uncertainty in the final inversion that is introduced through errors in the source retrieval.
Analyses of atmospheric heat and moisture budgets serve as an effective tool to study convective characteristics over a region and to provide large-scale forcing fields for various modeling applications. This paper examines two popular methods for computing large-scale atmospheric budgets: the conventional budget method (CBM) using objectively gridded analyses based primarily on radiosonde data and the constrained variational analysis (CVA) approach which supplements vertical profiles of atmospheric fields with measurements at the top of the atmosphere and at the surface to conserve mass, water, energy, and momentum. Successful budget computations are dependent on accurate sampling and analyses of the thermodynamic state of the atmosphere and the divergence field associated with convection and the large-scale circulation that influences it. Utilizing analyses generated from data taken during Dynamics of the Madden-Julian Oscillation (DYNAMO) field campaign conducted over the central Indian Ocean from October to December 2011, we evaluate the merits of these budget approaches and examine their limitations. While many of the shortcomings of the CBM, in particular effects of sampling errors in sounding data, are effectively minimized with CVA, accurate large-scale diagnostics in CVA are dependent on reliable background fields and rainfall constraints. Finally, for the DYNAMO analyses examined, the operational model fields used as the CVA background state provided wind fields that accurately resolved the vertical structure of convection in the vicinity of Gan Island. However, biases in the model thermodynamic fields were somewhat amplified in CVA resulting in a convective environment much weaker than observed.
The upper-air sounding network for DYNAMO (Dynamics of the Madden-Julian Oscillation or MJO) has provided an unprecedented set of observations for studying the MJO over the Indian Ocean (IO) where coupling of this oscillation with deep convection first occurs. With 72 sounding sites and dropsonde data from 13 aircraft mission, the sonde network covers the tropics from Eastern African to the West Pacific. In total nearly 26,000 sondes were collected from this network during the experiment’s 6-month extended observing period (from October 2011 to March 2012). Slightly more than half of the sondes, collected from 33 sites, are at high vertical resolution. Rigorous post-field phase processing of the sonde data included several levels of quality checks and a variety of corrections which address a number of issues (e.g., daytime dry bias, baseline surface data errors, ship deck-heating effects, artificial dry spikes in slow ascent sondes). Because of the importance of an accurate description of the moisture field in meeting the scientific goals of the experiments, particular attention is given to humidity correction and its validation. The humidity corrections, though small relative to some previous field campaigns, produced high fidelity moisture analyses in which sonde precipitable water compared well with independent estimates. An assessment of model operational analyses moisture using corrected sonde data shows an overall good agreement with the exception at upper-levels where model moisture and clouds are more abundant than the sounding data would indicate.
Several enhancements were recently made to the Haleakala polarimeter. Linear array detectors provide simultaneous resolution over a 3-A wavelength range, with spectral resolution of 40 mA. Optical fibers are now used to carry the intensity-modulated light from the rotating quarter-wave plate polarimeter to the echelle spectrometer, permitting its removal from the spar to a more stable environment. These changes, together with improved quarter-wave plates, reduced systematic errors to a few parts in 10,000 for routine observations. Examples of Stokes profiles and derived magnetic field maps are presented.
Here, we assess the error in three treatments of a critical electron beam diagnostic for laser-plasma acceleration (LPA) experiments: a permanent magnet electron spectrometer. Since LPA electron spectrometers are often difficult to calibrate due to the scarcity of well-characterized, tunable electron beam sources in the appropriate energy range and the mechanical complexity of electron spectrometers, the standard of calibration is Hall probe measurements. We first compare the electron spectrometer performance between SIMION calculations and the Hall probe measurements. We find up to a 60% (<8%) error in determining the absolute energy for electrons below (above) 80 MeV when using the SIMION-modeled magnetic field vs the measured magnetic field due to SIMION overpredicting fringe field strength. The difference in spectrometer energy resolution is within ∼10% between the modeled and measured fields. We then assess a simple block model, which is commonly used. We find that the simple block model presented here sufficiently captures the predicted as-built spectrometer performance for any application provided that the user can tolerate uncertainties on absolute energy determination up to 5% and errors on energy resolution up to 1%.
Quantum many-body systems involving bosonic modes or gauge fields have infinite-dimensional local Hilbert spaces which must be truncated to perform simulations of real-time dynamics on classical or quantum computers. To analyze the truncation error, we develop methods for bounding the rate of growth of local quantum numbers such as the occupation number of a mode at a lattice site, or the electric field at a lattice link. Our approach applies to various models of bosons interacting with spins or fermions, and also to both abelian and non-abelian gauge theories. We show that if states in these models are truncated by imposing an upper limit Λ on each local quantum number, and if the initial state has low local quantum numbers, then an error at most ϵ can be achieved by choosing Λ to scale polylogarithmically with ϵ − 1 , an exponential improvement over previous bounds based on energy conservation. For the Hubbard-Holstein model, we numerically compute a bound on Λ that achieves accuracy ϵ , obtaining significantly improved estimates in various parameter regimes. We also establish a criterion for truncating the Hamiltonian with a provable guarantee on the accuracy of time evolution. Building on that result, we formulate quantum algorithms for dynamical simulation of lattice gauge theories and of models with bosonic modes; the gate complexity depends almost linearly on spacetime volume in the former case, and almost quadratically on time in the latter case. We establish a lower bound showing that there are systems involving bosons for which this quadratic scaling with time cannot be improved. By applying our result on the truncation error in time evolution, we also prove that spectrally isolated energy eigenstates can be approximated with accuracy ϵ by truncating local quantum numbers at Λ = polylog ( ϵ − 1 ) .
Purpose: The goal of this study is to quantify the interfraction reproducibility of patient-specific motion models derived from 4DCBCT acquired on the day of treatment of lung cancer stereotactic body radiotherapy (SBRT) patients. Methods: Motion models are derived from patient 4DCBCT images acquired daily over 3–5 fractions of treatment by 1) applying deformable image registration between each 4DCBCT image and a reference phase from that day, resulting in a set of displacement vector fields (DVFs), and 2) performing principal component analysis (PCA) on the DVFs to derive a motion model. The motion model from the first day of treatment is compared to motion models from each successive day of treatment to quantify variability in motion models generated from different days. Four SBRT patient datasets have been acquired thus far in this IRB approved study. Results: Fraction-specific motion models for each fraction and patient were derived and PCA eigenvectors and their associated eigenvalues are compared for each fraction. For the first patient dataset, the average root mean square error between the first two eigenvectors associated with the highest two eigenvalues, in four fractions was 0.1, while it was 0.25 between the last three PCA eigenvectors associated with the lowest three eigenvalues. It was found that the eigenvectors and eigenvalues of PCA motion models for each treatment fraction have variations and the first few eigenvectors are shown to be more stable across treatment fractions than others. Conclusion: Analysis of this dataset showed that the first two eigenvectors of the PCA patient-specific motion models derived from 4DCBCT were stable over the course of several treatment fractions. The third, fourth, and fifth eigenvectors had larger variations.
Radio observations at 610 MHz and optical plates were obtained for five fields centered on the unidentified X-ray sources 3U0042 + 32, 3U0917 + 63, 3U1443 + 43, 3U1555 + 27, and 3U1809 + 50. For the first three fields, several radio sources are found which are associated with stellar objects within or near the X-ray error boxes. A 'tailed' radio galaxy has been found in Abell 2142, and this cluster is suggested as the identification for 3U1555 + 27. Although there are no radio sources greater than 0.1 flux unit within the X-ray error boxes associated with 3U1809 + 50, a Zwicky cluster surrounding the 3U position contains two radio galaxies: one with an inverted spectrum and another with a wide-angle tail. A table of positions, intensities, and suggested optical identifications is given for the 249 radio sources detected in the five fields.
Global food production in the developing world occurs within sub-hectare fields that are difficult to identify with moderate resolution satellite imagery. Knowledge about the distribution of these fields is critical in food security programs. We developed a semi-automated image segmentation approach using wall-to-wall sub-meter imagery with high-performance computing to map crop area (CA) throughout Tigray, Ethiopia that encompasses over 41,000 km (exp 2). Multiple processing streams were tested to minimize mapping error while applying five unique smoothing kernels to capture differences in land surface texture associated to CA. Typically, very-small fields (mean < 2 ha) have a smooth image roughness compared to natural scrub/shrub woody vegetation at the ~1m scale and these features can be segmented in panchromatic imagery with multi-level histogram thresholding. Multi-temporal very-high resolution (VHR) panchromatic imagery with multi-spectral VHR are sufficient in extracting critical CA information needed in food security programs. A 2011 to 2015 CA map was produced, using over 3000 WorldView-1 panchromatic images wall-to-wall in 1/2 deg mosaics for Tigray, Ethiopia. CA was evaluated with nearly 3000 WorldView-2 2m multispectral 250 X 250 m image subsets by seven expert interpretations, and with in-situ global positioning system photography. CA estimates ranged from 32 to 41% in sub regions of Tigray with median maximum per bin commission and omission errors of 11% and 1% respectively, with most of the error occurring in bins <15%. This empirical, simple, and low direct cost approach via U.S. government license agreement to access commercial VHR data, could be a viable big-data high-performance computing methodology to extract wall-to-wall CA for other regions of the world that have very-small agriculture fields with similar image texture."
A field test of the Descent Advisor (DA) automation tool was conducted at the Denver Air Route Traffic Control Center in September 1994. DA is being developed to assist Center controllers in the efficient management and control of arrival traffic. DA generates advisories, based on trajectory predictions, to achieve accurate meter-fix arrival times in a fuel efficient manner while assisting the controller with the prediction and resolution of potential conflicts. The test objectives were to evaluate the accuracy of DA trajectory predictions for conventional- and flight-management-system-equipped jet transports, to identify significant sources of trajectory prediction error, and to investigate procedural and training issues (both air and ground) associated with DA operations. Various commercial aircraft (97 flights total) and a Boeing 737-100 research aircraft participated in the test. Preliminary results from the primary test set of 24 commercial flights indicate a mean DA arrival time prediction error of 2.4 sec late with a standard deviation of 13.1 sec. This paper describes the field test and presents preliminary results for the commercial flights.
We present the combination of optical data from the Science Verification phase of the Dark Energy Survey (DES) with near-infrared (NIR) data from the European Southern Observatory VISTA Hemisphere Survey (VHS). The deep optical detections from DES are used to extract fluxes and associated errors from the shallower VHS data. Joint seven-band ( grizYJK ) photometric catalogues are produced in a single 3 sq-deg dedicated camera field centred at 02h26m-04d36m where the availability of ancillary multiwavelength photometry and spectroscopy allows us to test the data quality. Dual photometry increases the number of DES galaxies with measured VHS fluxes by a factor of ~4.5 relative to a simple catalogue level matching and results in a ~1.5 mag increase in the 80 per cent completeness limit of the NIR data. Almost 70 per cent of DES sources have useful NIR flux measurements in this initial catalogue. Photometric redshifts are estimated for a subset of galaxies with spectroscopic redshifts and initial results, although currently limited by small number statistics, indicate that the VHS data can help reduce the photometric redshift scatter at both z < 0.5 and z > 1. We present example DES+VHS colour selection criteria for high-redshift luminous red galaxies (LRGs) at z ~ 0.7 as well as luminous quasars. Using spectroscopic observations in this field we show that the additional VHS fluxes enable a cleaner selection of both populations with <10 per cent contamination from galactic stars in the case of spectroscopically confirmed quasars and <0.5 per cent contamination from galactic stars in the case of spectroscopically confirmed LRGs. The combined DES+VHS data set, which will eventually cover almost 5000 sq-deg, will therefore enable a range of new science and be ideally suited for target selection for future wide-field spectroscopic surveys.
A field test of the Descent Advisor (DA) automation tool was conducted at the Denver Air Route Traffic Control Center in September 1994. DA is being developed to assist Center controllers in the efficient management and control of arrival traffic. DA generates advisories, based on trajectory predictions, to achieve accurate meter-fix arrival times in a fuel efficient manner while assisting the controller with the prediction and resolution of potential conflicts. The test objectives were: (1) to evaluate the accuracy of DA trajectory predictions for conventional and flight-management system equipped jet transports, (2) to identify significant sources of trajectory prediction error, and (3) to investigate procedural and training issues (both air and ground) associated with DA operations. Various commercial aircraft (97 flights total) and a Boeing 737-100 research aircraft participated in the test. Preliminary results from the primary test set of 24 commercial flights indicate a mean DA arrival time prediction error of 2.4 seconds late with a standard deviation of 13.1 seconds. This paper describes the field test and presents preliminary results for the commercial flights.
Purpose: Several shortcomings of the current implementation of the analytic anisotropic algorithm (AAA) may lead to dose calculation errors in highly modulated treatments delivered to highly heterogeneous geometries. Here we introduce a set of dosimetric error predictors that can be applied to a clinical treatment plan and patient geometry in order to identify high risk plans. Once a problematic plan is identified, the treatment can be recalculated with more accurate algorithm in order to better assess its viability. Methods: Here we focus on three distinct sources dosimetric error in the AAA algorithm. First, due to a combination of discrepancies in smallfield beam modeling as well as volume averaging effects, dose calculated through small MLC apertures can be underestimated, while that behind small MLC blocks can overestimated. Second, due the rectilinear scaling of the Monte Carlo generated pencil beam kernel, energy is not properly transported through heterogeneities near, but not impeding, the central axis of the beamlet. And third, AAA overestimates dose in regions very low density (< 0.2 g/cm{sup 3}). We have developed an algorithm to detect the location and magnitude of each scenario within the patient geometry, namely the field-size index (FSI), the heterogeneous scatter index (HSI), and the lowdensity index (LDI) respectively. Results: Error indices successfully identify deviations between AAA and Monte Carlo dose distributions in simple phantom geometries. Algorithms are currently implemented in the MATLAB computing environment and are able to run on a typical RapidArc head and neck geometry in less than an hour. Conclusion: Because these error indices successfully identify each type of error in contrived cases, with sufficient benchmarking, this method can be developed into a clinical tool that may be able to help estimate AAA dose calculation errors and when it might be advisable to use Monte Carlo calculations.
Purpose: The measurement based on Shack-Hartmann wave-front sensor(WFS), obtaining both the high and low order wave-front aberrations simultaneously and accurately, has been applied in the detection of human eyes aberration in recent years. However, Its application is limited by the small field of view (FOV), slight eye movement leads the optical bacon image exceeds the lenslet array which result in uncertain detection error. To overcome difficulties of precise eye location, the capacity of detecting eye wave-front aberration over FOV much larger than simply a single conjugate Hartmann WFS accurately and simultaneously is demanded. Methods: Plenoptic camera’s lenslet array subdivides the aperture light-field in spatial frequency domain, capture the 4-D light-field information. Data recorded by plenoptic cameras can be used to extract the wave-front phases associated to the eyes aberration. The corresponding theoretical model and simulation system is built up in this article to discuss wave-front measurement performance when utilizing plenoptic camera as wave-front sensor. Results: The simulation results indicate that the plenoptic wave-front method can obtain both the high and low order eyes wave-front aberration with the same accuracy as conventional system in single visual angle detectionand over FOV much larger than simply a single conjugate Hartmann systems. Meanwhile, simulation results show that detection of eye aberrations wave-front in different visual angle can be achieved effectively and simultaneously by plenoptic method, by both point and extended optical beacon from the eye. Conclusion: Plenoptic wave-front method possesses the feasibility in eye aberrations wave-front detection. With larger FOV, the method can effectively reduce the detection error brought by imprecise eye location and simplify the eye aberrations wave-front detection system comparing with which based on Shack-Hartmann WFS. Unique advantage of the plenoptic method lies in obtaining wave-front in different visual angle simultaneously, which provides an approach in building up 3-D model of eye refractor tomographically. Funded by the key Laboratory of High Power Laser and Physics, CAS Research Project of National University of Defense Technology No. JC13-07-01; National Natural Science Foundation of China No. 61205144.
The presentation will cover a variety of mitigation strategies that were developed for critical applications. An emphasis is placed on strengths and weaknesses per mitigation technique as it pertains to different FPGA device types.