Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Effects of vertical distribution of water vapor and temperature on total column water vapor retrieval error

Results are presented of a test of the physically based total column water vapor retrieval algorithm of Wentz (1992) for sensitivity to realistic vertical distributions of temperature and water vapor. The ECMWF monthly averaged temperature and humidity fields are used to simulate the spatial pattern of systematic retrieval error of total column water vapor due to this sensitivity. The estimated systematic error is within 0.1 g/sq cm over about 70 percent of the global ocean area; systematic errors greater than 0.3 g/sq cm are expected to exist only over a few well-defined regions, about 3 percent of the global oceans, assuming that the global mean value is unbiased.

Sun, Jielun↗

Calibration of TOPEX/POSEIDON at Platform Harvest

We present estimates for the mean bias of the TOPEX/POSEIDON NASA altimeter (ALT) and the Centre National d'Etudes Spatiales altimeter (SSALT) using in-situ data gathered at Platform Harvest during the first 36 cycles of the mission. Data for 21 overflights of the ALT and six overflights of the SSALT have been analyzed. The analysis includes an independent assessment of in-situ measurements of sea level, the radial component of the orbit, wet tropospheric path delay, and ionospheric path delay. (The sign convention used is such that, to correct the geophysical data record values for sea level, add the bias algebraically. Unless otherwise stated, the uncertainty in a given parameter is depicted by +/- sigma(sub x), where sigma(sub x) is the sample standard deviation of x about the mean.) Tide gauges at Harvest provide estimates of sea level with an uncertainty of +/- 1.5 cm. The uncertainty in the radial component of the orbit is estimated to be +/- 1.3 cm. In-situ measurements of tropopsheric path delay at Harvest compare to within +/- 1.3 cm of the TOPEX/POSEIDON microwave radiometer, and in-situ measurements of the ionospheric path delay compare to within -0.4 +/- 0.7 cm of the dual-frequency ALT and 1.1 +/- 0.6 cm of Doppler orbitography and radiopositioning integrated by satellite. We obtain mean bias estimates of -14.5 +/- 2.9 cm for the ALT and +0.9 +/- 3.1 cm for the SSALT (where the uncertainties are based on the standard deviation of the estimated mean (sigma(sub bar x/y), which is derived from sample statistics and estimates for errors that cannot be observed). These results are consistent with independent estimates for the relative bias between the two altimeters. A linear regression applied to the complete set of data shows that there is a discernable secular trend in the time series for the ALT bias estimates. A preliminary analysis of data obtained through cycle 48 suggests that the apparent secular drift may be the result of a poorly sampled annual signal.

Christensen, E. J.↗

Using Digital Image Correlation for Material Testing at Cryogenic Temperatures

Recent efforts were made to parametrize an aluminum alloy at cryogenic temperatures to calibrate finite element models simulating material deformation. Digital image correlation (DIC) was used to measure material properties using front/back strains of specimens during tensile tests. Data acquired from DIC was compared to physical extensometer measurements. Two camera pairs (front and back) were mounted via aluminum extrusion to the exterior of an environmental chamber of a hydraulic test stand. Images were taken through single-pane optical glass windows of the environment chamber. Positive pressure bags encased the cameras, attaching to the perimeter of the glass to keep out moisture and prevent windows from frosting. Figure 1 shows the environmental setup and the camera setup during cryogenic testing. Some of the challenges during testing at cryogenic temperatures include the gaseous flow of liquid nitrogen in the optical path of the mounted cameras, frost buildup on the windows as seen in Figure 1b, and frost on the test coupon. The temperature gradient present during the introduction of liquid nitrogen into the chamber can increase the projection error of images captured of the specimen. Figure 2 shows the estimated projection error from DIC as a function of temperature during the cool down process. This presentation addresses some of the concerns and observations when using DIC for testing at cryogenic temperatures using methods of isolated camera system and techniques for maintaining the glass panel clear from frost.

Joseph Cochran↗

Underlying Fundamentals of Kalman Filtering for River Network Modeling

The grand challenge of producing hydrometeorological estimates every time and everywhere has motivated the fusion of sparse observations with dense numerical models, with a particular interest on discharge in river modeling. Ensemble methods are largely preferred as they enable the estimation of error properties, but at the expense of computational load and generally with underestimations. These imperfect stochastic estimates motivate the use of correction methods, that is, error localization and inflation, although the physical justifications for their optimality are limited. The purpose of this study is to use one of the simplest forms of data assimilation when applied to river modeling and reveal the underlying mechanisms impacting its performance. Our framework based on assimilating daily averaged in situ discharge measurements to correct daily averaged runoff was tested over a 4-yr case study of two rivers in Texas. Results show that under optimal conditions of inflation and localization, discharge simulations are consistently improved such that the mean values of Nash–Sutcliffe efficiency are enhanced from211.32 to 0.55 at observed gauges and from212.24 to21.10 at validation gauges. Yet, parameters controlling the inflation and the localization have a large impact on the performance. Further investigations of these sensitivities showed that optimal inflation occurs when compensating exactly for discrepancies in the magnitude of errors while optimal localization matches the distance traveled during one assimilation window. These results may be applicable to more advanced data assimilation methods as well as for larger applications motivated by upcoming river-observing satellite missions, such as NASA’s Surface Water and Ocean Topography mission.

Streamflow↗

CATASTROPHIC PHOTO-z ERRORS AND THE DARK ENERGY PARAMETER ESTIMATES WITH COSMIC SHEAR

We study the impact of catastrophic errors occurring in the photometric redshifts of galaxies on cosmological parameter estimates with cosmic shear tomography. We consider a fiducial survey with nine-filter set and perform photo-z measurement simulations. It is found that a fraction of 1% galaxies at z{sub spec} {approx} 0.4 is misidentified to be at z{sub phot} {approx} 3.5. We then employ both {chi}{sup 2} fitting method and the extension of Fisher matrix formalism to evaluate the bias on the equation of state parameters of dark energy, w {sub 0} and w {sub a} , induced by those catastrophic outliers. By comparing the results from both methods, we verify that the estimation of w{sub 0} and w{sub a} from the fiducial five-bin tomographic analyses can be significantly biased. To minimize the impact of this bias, two strategies can be followed: (1) the cosmic shear analysis is restricted to 0.5 < z < 2.5, where catastrophic redshift errors are expected to be insignificant; (2) a spectroscopic survey is conducted for galaxies with 3 < z{sub phot} < 4. We find that the number of spectroscopic redshifts needed scales as N{sub spec} {proportional_to} f{sub cata} x A, where f{sub cata} = 1% is the fraction of catastrophic redshift errors (assuming a nine-filter photometric survey) and A is the survey area. For A = 1000deg{sup 2}, we find that N{sub spec} > 320 and 860, respectively, in order to reduce the joint bias in (w{sub 0}, w{sub a} ) to be smaller than 2{sigma} and 1{sigma}. This spectroscopic survey (option 2) will improve the figure of merit of option 1 by a factor x1.5 thus making such a survey strongly desirable.

79 ASTRONOMY AND ASTROPHYSICS↗

EFFECT OF DISCRETIZATION ERROR ON THE QUANTIFICATION OF MODEL UNCERTAINTY IN TWO-PHASE FLOW SIMULATIONS

Verification, validation and uncertainty quantification (VVUQ) have become a common practice in thermal-hydraulics analysis. In general, these activities deal with propagations of uncertainties in computer code simulations, e.g., through system analysis codes. However, most existing such activities in thermal-hydraulics analysis have been primarily focused on input and model uncertainties, while numerical errors were largely overlooked. Numerical errors can appear in many different forms, e.g., round-off error, statistical sampling error, and discretization error. In thermal-hydraulics analysis, especially two-phase flow simulations commonly encountered in reactor safety analysis, the lack of consideration of discretization error is mainly due to the difficulty in estimating them. Accurate estimations of discretization error require continuous mesh refinement and/or implementation of high-order numerical schemes in system analysis code, both of which are difficult to achieve in existing codes. In this work, we will build a computer code that incorporates both first-order and second-order numerical methods to solve the two-phase flow problems. The first-order method resembles the one used in many existing system analysis codes; and the second-order method works as the reference to estimate numerical errors. Numerical verification of spatial discretization schemes will be presented in the form of mesh convergence study. It will also be demonstrated via case studies that, in practical scenarios, discretization errors can be as large as, or even larger than, model uncertainties.

42 ENGINEERING↗

Single Event Test Methodologies and System Error Rate Analysis for Triple Modular Redundant Field Programmable Gate Arrays

We present a test methodology for estimating system error rates of Field Programmable Gate Arrays (FPGAs) mitigated with Triple Modular Redundancy (TMR). The test methodology is founded in a mathematical model, which is also presented. Accelerator data from 90 nm Xilins Military/Aerospace grade FPGA are shown to fit the model. Fault injection (FI) results are discussed and related to the test data. Design implementation and the corresponding impact of multiple bit upset (MBU) are also discussed.

error rate calculations↗

Bottomonium spectrum from lattice QCD with 2+1 flavors of domain wall fermions

Recently, realistic lattice QCD calculations with 2+1 flavors of domain wall fermions and the Iwasaki gauge action have been performed by the RBC and UKQCD Collaborations. Here, results for the bottomonium spectrum computed on their gauge configurations of size 24{sup 3}x64 with a lattice spacing of approximately 0.11 fm and four different values for the light quark mass are presented. Improved lattice nonrelativistic QCD is used to treat the b quarks inside the bottomonium. The results for the radial and orbital energy splittings are found to be in good agreement with experimental measurements, indicating that systematic errors are small. The calculation of the {upsilon}(2S)-{upsilon}(1S) energy splitting provides an independent determination of the lattice spacing. For the most physical ensemble it is found to be a{sup -1}=1.740(25)(19) GeV, where the first error is statistical/fitting and the second error is an estimate of the systematic errors due to the lattice nonrelativistic QCD action.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Procedure for Calculating the Vertical Space Height of the Sacrum When Determining Skeletal Height for Use in the Anatomical Method of Adult Stature Estimation

Abstract Estimating stature from skeletonized remains is one of the essential parameters in the development of a biological profile. A new procedure for determining skeletal height ( SKH ) incorporating the vertical space height ( VSH ) from the anterior margin of the sacral promontory to the superior margins of the acetabulae for use in the anatomical method of stature estimation is introduced. Regression equations for stature estimation were generated from measurements of 38 American males of European ancestry from the William M. Bass Donated Skeletal Collection. The modification to the procedure results in a SKH that is highly correlated with stature ( r = 0.925–0.948). Stature estimates have low standard errors of the estimate ranging from 21.79 to 25.95 mm, biases from to 0.50 to 0.94 mm, and accuracy rates from 17.71 mm to 19.45 mm. The procedure for determining the VSH , which replaces “S1 height” in traditional anatomical method models, is a key improvement to the method.

Hayashi, Atsuko↗

X-ray emission from the region of gamma 195+5

In the present study, the region of the gamma 195 + 5 was searched for X-ray emission to a level of approximately 10 to the minus eleventh erg/sq cm-sec. A source is detected whose position is in agreement with the position of the gamma-ray source. The area of the X-ray box is approximately five times smaller than the estimated gamma-ray error region; it will guide further observations at X-ray and other wavelengths. The probability that the source is located by chance within the gamma-ray error region is estimated at 9%. The X-ray spectrum appears to be too steep to extrapolate simply toward the 100 MeV point.

Lamb, R. C.↗

Statistical tests for closure of plate motion circuits

Two methods, one based on a chi-square test and the second on an F-ratio test, of testing for the plate motion circuit closures are described and evaluated. The chi-square test is used to evaluate goodness of fit, and it is assumed that the assigned errors are accurate estimates of the true errors in the data. The F-ratio test is used to compare variances of distributions, and it is assumed that the relative values of assigned error are accurate. The two methods are applied to the data of Minster and Jordan (1978) on the motion of the three plates that meet at the Galapagos Triple Junction, and the motion of the three plates that meet at the Indian Ocean Triple Junction. It is noted that the F-ratio plate circuit closure test is more useful than the chi-square test for identifying systematic misfits in data because the chi-square test overestimates the errors of plate motion data.

Gordon, Richard G.↗

Adaptive methods in computational fluid dynamics

A review is conducted of the basic components of adaptive methods applicable to very complex problems in fluid dynamics. Attention is given to ways of changing the structure of an approximation to reduce error, techniques for estimating the evolution of error in a CFD calculation, and the range of algorithms that are currently available for mesh-changing functions. Available numerical results which demonstrate the viability of these approaches are discussed.

Oden, J. T.↗

Nonlinear Observers for Gyro Calibration Coupled with a Nonlinear Control Algorithm

Nonlinear observers for gyro calibration are presented. The first observer estimates a constant gyro bias. The second observer estimates scale factor errors. The third observer estimates the gyro alignment for three orthogonal gyros. The observers are then combined. The convergence properties of all three observers, and the combined observers, are discussed. Additionally, all three observers are coupled with a nonlinear control algorithm. The stability of each of the resulting closed loop systems is analyzed. Simulated test results are presented for each system.

Thienel, Julie↗

Nonlinear Observers for Gyro Calibration

Nonlinear observers for gyro calibration are presented. The first observer estimates a constant gyro bias. The second observer estimates scale factor errors. The third observer estimates the gyro alignment for three orthogonal gyros. The convergence properties of all three observers are discussed. Additionally, all three observers are coupled with a nonlinear control algorithm. The stability of each of the resulting closed loop systems is analyzed. Simulated test results are presented for each system.

Thienel, Julie↗

Is There A Relationship Between Cornered-Hat Methods and A Residual Approach to Estimate System Uncertainty?

Recently a relationship has been established between a now traditional residual diagnostic used to estimate observation, background and analysis error covariances of interest to data assimilation and the three-cornered hat (3CH) method. An existing extension of the traditional residual diagnostic uses residuals from a fixed lag-1 Kalman smoother to retrieve system (model) error covariance. It is thus natural to ask if an additional relationship can be established between this extended residual method and some form of cornered--hat method. The answer might seem straightforward. Unlike in the standard residual estimation case, attempting to estimate model error amounts to estimating the statistics of a residual quantity itself. As shown in this presentation, in such cases the 3CH method becomes trivial: the sought out uncertainty can be derived directly from the covariance of the residual quantity at hand. In the particular case of estimating model error, one of the corners would have to be composed of vectors providing estimates of model error; these are not typically available in practice. Therefore, at first glance the present work finds no relationship between the lag-1 smoother residual diagnostic for system error estimation and cornered--hat methods. However, the work suggests that a two-tiered 3CH might be all that is necessary for system uncertainty to be obtained with 3CH.

Ricardo Todling↗

Towards a more realistic representation of NASA CERES-derived surface radiative fluxes during polar night: a comparison with the MOSAiC field campaign

The Arctic is one of the most sensitive regions of Earth to climate change, and yet remains one of the more difficult regions to both observe and simulate. The high latitude of the Arctic gives it some unusual features compared with much of Earth, such as large and variable sea ice cover, extensive mixed phase cloud cover, and the polar day/night cycle. These features significantly influence the radiative environment of the Arctic as well as the ability to observe it. The remoteness of the Arctic from most of civilization makes large volumes of in situ observations difficult to collect, and so satellite observations are a critical tool for observing the region, such as those from Clouds and the Earth’s Radiant Energy System (CERES). But validating the satellite radiative flux estimates is difficult because of the lack of in situ measurements. A useful remedy is utilizing measurements from field campaigns, such as the year-long Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition during 2019-2020. The extensive high-quality surface radiative flux and meteorological measurements collected from MOSAiC provide a useful check on flux retrievals from CERES instruments. Previous work compared MOSAiC and CERES surface radiative fluxes during the 2020 melt season (April-September). Errors in CERES fluxes were related to errors in estimated atmospheric optical depth and surface albedo. We conduct a similar assessment of CERES surface flux retrievals using MOSAiC data, but for the months of October through March instead. As this time period is mostly during polar night and twilight, the focus of the study is on longwave surface fluxes. To better understand the reasons for errors in CERES fluxes, we use the large set of meteorological measurements also collected by MOSAiC, including surface temperature, thermodynamic vertical profiles, surface turbulent fluxes, and cloud properties. For example, one notable possible source of error in the CERES estimate of surface downwelling longwave flux is the estimate of cloud base height when compared with MOSAiC W-band radar measurements – an overestimate of cloud base height yields an underestimate of the downwelling flux on the order of tens of W m2.

J. Brant Dodson↗

Analysis of the inter-species power balance in JET plasmas

Most auxiliary heating methods provide heating to more than one particle species (electrons, ions, impurities) in a fusion plasma. This can lead to substantial temperature differences between species, depending on conditions such as heating power to the different species and collisionality, with temperature differences between species limited by inter-species thermal equipartition and transport. The analysis of the steady-state electron-ion and impurity-ion power balances presented in this paper are used for consistency-checking experimental ion and electron temperature measurements and for inferring the main ion temperature from measured impurity temperatures. As ion temperature measurements by charge exchange spectroscopy (CXS) based on impurity ions have become more difficult and time-consuming since the installation of the ITER-like wall (ILW) with Be and W PFC's, knowing the maximum sustainable temperature difference between ions and electrons, |T i -T e | allows rejecting erroneous measurements. It also obviates the need for an ion temperature measurement, if an electron temperature measurement is available and |T i - T e | cannot be larger than the combined errors of the underlying measurements. A power balance analysis is also required for estimating the errors of the ion and electron heat fluxes prior to any species-resolved transport analysis. The ion-impurity temperature differences are usually found to be small due to strong thermal equipartition between ion species. However, they can approach 10% in JET-ILW low density, high power discharges, such the ones under development for a future JET deuterium–tritium campaign (Joffrin et al 2019 Nucl. Fusion). This has a generally small, but not always negligible effect on the calculation of fusion reaction rates, which depend on main ion temperatures. An important outcome of this analysis is that temperature differences between impurity species are always much smaller than between the impurities and hydrogenic species and can usually be neglected. The article presents two methods for calculating the impurity-to-main ion temperature ratio. Finally, this analysis leads to a method for the reconstruction ion temperature profiles from ion temperature data available at only one or a small number of spatial locations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗