Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error correction.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Thresholds of surface codes on the general lattice structures suffering biased error and loss

A family of surface codes with general lattice structures is proposed. We can control the error tolerances against bit and phase errors asymmetrically by changing the underlying lattice geometries. The surface codes on various lattices are found to be efficient in the sense that their threshold values universally approach the quantum Gilbert-Varshamov bound. We find that the error tolerance of the surface codes depends on the connectivity of the underlying lattices; the error chains on a lattice of lower connectivity are easier to correct. On the other hand, the loss tolerance of the surface codes exhibits an opposite behavior; the logical information on a lattice of higher connectivity has more robustness against qubit loss. As a result, we come upon a fundamental trade-off between error and loss tolerances in the family of surface codes with different lattice geometries.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accurate shear measurement with faint sources

For cosmic shear to become an accurate cosmological probe, systematic errors in the shear measurement method must be unambiguously identified and corrected for. Previous work of this series has demonstrated that cosmic shears can be measured accurately in Fourier space in the presence of background noise and finite pixel size, without assumptions on the morphologies of galaxy and PSF. The remaining major source of error is source Poisson noise, due to the finiteness of source photon number. This problem is particularly important for faint galaxies in space-based weak lensing measurements, and for ground-based images of short exposure times. In this work, we propose a simple and rigorous way of removing the shear bias from the source Poisson noise. Our noise treatment can be generalized for images made of multiple exposures through MultiDrizzle. This is demonstrated with the SDSS and COSMOS/ACS data. With a large ensemble of mock galaxy images of unrestricted morphologies, we show that our shear measurement method can achieve sub-percent level accuracy even for images of signal-to-noise ratio less than 5 in general, making it the most promising technique for cosmic shear measurement in the ongoing and upcoming large scale galaxy surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved diffusion coefficients generated from Monte Carlo codes

Monte Carlo codes are becoming more widely used for reactor analysis. Some of these applications involve the generation of diffusion theory parameters including macroscopic cross sections and diffusion coefficients. Two approximations used to generate diffusion coefficients are assessed using the Monte Carlo code MC21. The first is the method of homogenization; whether to weight either fine-group transport cross sections or fine-group diffusion coefficients when collapsing to few-group diffusion coefficients. The second is a fundamental approximation made to the energy-dependent P1 equations to derive the energy-dependent diffusion equations. Standard Monte Carlo codes usually generate a flux-weighted transport cross section with no correction to the diffusion approximation. Results indicate that this causes noticeable tilting in reconstructed pin powers in simple test lattices with L2 norm error of 3.6%. This error is reduced significantly to 0.27% when weighting fine-group diffusion coefficients by the flux and applying a correction to the diffusion approximation. Noticeable tilting in reconstructed fluxes and pin powers was reduced when applying these corrections. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TH-A-BRF-01: A Probabilistic Bayesian Approach to Derive Electron Density From MRI for Radiation Therapy Treatment Planning

Purpose: MRI significantly improves the accuracy and reliability of target delineation for patient simulation and treatment planning in radiation therapy, due to its superior soft tissue contrast as compared to CT. An MRI based simulation will reduce cost and simplify clinical workflow with zero ionizing radiation. However, MRI lacks the key electron density information. The purpose of this work is to develop a reliable method to derive electron density from MRI. Methods: We adopt a probabilistic Bayesian approach for electron density mapping based on T1-weighted head MRI. For each voxel, we compute conditional probability of electron densities given its: (1) T1 intensity and (2) geometry in a reference anatomy, obtained by deformable image registration between the MRI of test patient and atlas. Intensity and geometry information are combined into a unifying posterior probability density function whose mean gives the electron density. Mean absolute HU error between the estimated and true CT, as well as ROC's for bone detection (HU>200) were calculated for 8 patients. The performance was compared with a global intensity approach based on T1 and no density correction (set whole head to water). Results: The proposed technique significantly reduced the errors in electron density estimation, with a mean absolute HU error of 132, compared with 139 for deformable registration (p=10{sup −3}), 371 for the intensity approach (p=10{sup −5}) and 282 without density correction (p=2×10{sup −4}). For 90% sensitivity in bone detection, the proposed method had a specificity of 85% and that for deformable registration, intensity and without density correction are 80%, 24% and 10% respectively. Conclusion: The proposed unifying method provides accurate electron density estimation and bone detection from MRI of the head with highly heterogeneous regions. This paves the way for accurate dose calculation and generating reference images for patient setup in MRI-based treatment planning.

60 APPLIED LIFE SCIENCES↗

Investigation of a Quantum Monte Carlo Protocol To Achieve High Accuracy and High-Throughput Materials Formation Energies

High-throughput calculations based on density functional theory (DFT) methods have been widely implemented in the scientific community. However, depending on both the properties of interest as well as particular chemical/structural phase space, accuracy even for correct trends remains a key challenge for DFT. In this work, we evaluate the use of quantum Monte Carlo (QMC) to calculate material formation energies in a high-throughput environment. We test the performance of automated QMC calculations on 21 compounds with high quality reference data from the Committee on Data for Science and Technology (CODATA) thermodynamic database. We compare our approach to different DFT methods as well as different pseudopotentials, showing that errors in QMC calculations can be progressively improved especially when correct pseudopotentials are used. We determine a set of accurate pseudopotentials in QMC via a systematic investigation of multiple available pseudopotential libraries. We show that using this simple automated recipe, QMC calculations can outperform DFT calculations over a wide set of materials. Out of 21 compounds tested, chemical accuracy has been obtained in formation energies of 11 structures using our QMC recipe, compared to none using DFT calculations.

Chemistry↗

On the significance of density-induced speed of sound variations on US-guided radiotherapy

Purpose: To show the effect of speed of sound (SOS) aberration on ultrasound guided radiotherapy (US-gRT) as a function of implemented workflow. US systems assume that SOS is constant in human soft tissues (at a value of 1540 m/s), while its actual nonuniform distribution produces small but systematic errors of up to a few millimeters in the positions of scanned structures. When a coregistered computerized tomography (CT) scan is available, the US image can be corrected for SOS aberration. Typically, image guided radiotherapy workflows implementing US systems only provide a CT scan at the simulation (SIM) stage. If changes occur in geometry or density distribution between SIM and treatment (TX) stage, SOS aberration can change accordingly, with a final impact on the measured position of structures which is dependent on the workflow adopted. Methods: Four basic scenarios were considered of possible changes between SIM and TX: (1) No changes, (2) only patient position changes (rigid rotation-translation), (3) only US transducer position changes (constrained on patient's surface), and (4) patient tissues thickness changes. Different SOS aberrations may arise from the different scenarios, according to the specific US-gRT workflow used: intermodality (INTER) where TX US scans are compared to SIM CT scans; intramodality (INTRA) where TX US scans are compared to SIM US scans; and INTERc and INTRAc where all US images are corrected for SOS aberration (using density information provided by SIM CT). For an experimental proof of principle, the effect of tissues thickness change was simulated in the different workflows: a dual layered phantom was filled with layers of sunflower oil (SOS 1478 m/s), water (SOS 1482 m/s), and 20% saline solution (SOS 1700 m/s). The phantom was US scanned, the layer thicknesses were increased and the US scans were repeated. The errors resulting from the different workflows were compared. Results: Theoretical considerations show that workflows implementing SOS correction based on SIM-CT scan (INTERc, INTRAc) give null errors in all scenarios except when tissues thickness changes, where an error proportional to the degree of change in SOS maps between SIM and TX ({Delta}SOS) occurs. An uncorrected workflow such as INTER produces in all scenarios a pure SOS error, while uncorrected INTRA produces a null error for rotation-translation of the patient, a {Delta}SOS error for changing tissues thickness and an error proportional to the degree of SOS distribution change along the different lines of view when shifting the transducer. The dual layered phantom demonstrated experimentally that the effect of SOS change between SIM and TX is clinically nonrelevant, being less than the intrinsic resolution of imaging systems, even when a substantial change in thicknesses is applied, provided that a SIM-CT-based SOS aberration correction is applied. Noncorrected workflows produce errors up to 4 mm for INTER and to 3 mm for INTRA in the phantom test. Conclusions: A SOS correction is advantageous for all US-gRT workflows and clinical cases, where the effect of SOS change can be considered a second order effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-G-BRA-05: Predicting Volume Change of the Tumor and Critical Structures Throughout Radiation Therapy by CT-CBCT Registration with Local Intensity Correction

Purpose: The purpose of this study is to develop an accurate and effective technique to predict and monitor volume changes of the tumor and organs at risk (OARs) from daily cone-beam CTs (CBCTs). Methods: While CBCT is typically used to minimize the patient setup error, its poor image quality impedes accurate monitoring of daily anatomical changes in radiotherapy. Reconstruction artifacts in CBCT often cause undesirable errors in registration-based contour propagation from the planning CT, a conventional way to estimate anatomical changes. To improve the registration and segmentation accuracy, we developed a new deformable image registration (DIR) that iteratively corrects CBCT intensities using slice-based histogram matching during the registration process. Three popular DIR algorithms (hierarchical B-spline, demons, optical flow) augmented by the intensity correction were implemented on a graphics processing unit for efficient computation, and their performances were evaluated on six head and neck (HN) cancer cases. Four trained scientists manually contoured nodal gross tumor volume (GTV) on the planning CT and every other fraction CBCTs for each case, to which the propagated GTV contours by DIR were compared. The performance was also compared with commercial software, VelocityAI (Varian Medical Systems Inc.). Results: Manual contouring showed significant variations, [-76, +141]% from the mean of all four sets of contours. The volume differences (mean±std in cc) between the average manual segmentation and four automatic segmentations are 3.70±2.30(B-spline), 1.25±1.78(demons), 0.93±1.14(optical flow), and 4.39±3.86 (VelocityAI). In comparison to the average volume of the manual segmentations, the proposed approach significantly reduced the estimation error by 9%(B-spline), 38%(demons), and 51%(optical flow) over the conventional mutual information based method (VelocityAI). Conclusion: The proposed CT-CBCT registration with local CBCT intensity correction can accurately predict the tumor volume change with reduced errors. Although demonstrated only on HN nodal GTVs, the results imply improved accuracy for other critical structures. This work was supported by NIH/NCI under grant R42CA137886.

60 APPLIED LIFE SCIENCES↗

Second derivatives for approximate spin projection methods

The use of broken-symmetry electronic structure methods is required in order to obtain correct behavior of electronically strained open-shell systems, such as transition states, biradicals, and transition metals. This approach often has issues with spin contamination, which can lead to significant errors in predicted energies, geometries, and properties. Approximate projection schemes are able to correct for spin contamination and can often yield improved results. To fully make use of these methods and to carry out exploration of the potential energy surface, it is desirable to develop an efficient second energy derivative theory. In this paper, we formulate the analytical second derivatives for the Yamaguchi approximate projection scheme, building on recent work that has yielded an efficient implementation of the analytical first derivatives.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calibration of low-temperature ac susceptometers with a copper cylinder standard

A high-quality low-temperature ac susceptometer is calibrated by comparing the measured ac susceptibility of a copper cylinder with its eddy-current ac susceptibility accurately calculated. Different from conventional calibration techniques that compare the measured results with the known property of a standard sample at certain fixed temperature T, field amplitude H{sub m}, and frequency f, to get a magnitude correction factor, here, the electromagnetic properties of the copper cylinder are unknown and are determined during the calibration of the ac susceptometer in the entire T, H{sub m}, and f range. It is shown that the maximum magnitude error and the maximum phase error of the susceptometer are less than 0.7% and 0.3 deg., respectively, in the region T=5-300 K and f=111-1111 Hz at H{sub m}=800 A/m, after a magnitude correction by a constant factor as done in a conventional calibration. However, the magnitude and phase errors can reach 2% and 4.3 deg. at 10 000 and 11 Hz, respectively. Since the errors are reproducible, a large portion of them may be further corrected after a calibration, the procedure for which is given. Conceptual discussions concerning the error sources, comparison with other calibration methods, and applications of ac susceptibility techniques are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Code Verification of Multiple Physics-Fidelity Models in Hypersonic Aerodynamics

Hypersonic aerodynamics models exist across a range of physics fidelities with associated computational expenses. These models may be run independently or in a multifidelity framework that leverages their complementary strengths of speed for lower-fidelity and accuracy for higher-fidelity models. This work presents applied code verification of two lower-fidelity models contained within the Sandia hypersonic aerodynamics code. Each model has a different form that requires individualized verification approaches, including comparison to analytical solutions as well as manufactured solutions with order-of-accuracy testing. In conclusion, results of this effort include the identification and resolution of code errors and shortcomings, as well as the demonstration of code correctness and consistency for both models.

Aerodynamics↗

Effect of Translational and Rotational Errors on Complex Dose Distributions With Off-Line and On-Line Position Verification

Purpose: To investigate the influence of translational and rotational errors on prostate intensity-modulated radiotherapy (IMRT) with an integrated boost to the tumor and to evaluate the effect of the use of an on-line correction protocol. Methods and Materials: For 19 patients, who had been treated with prostate IMRT and fiducial marker-based position verification, highly inhomogeneous IMRT plans, including an integrated tumor boost, were made using varying margins (2, 4, 6, and 8 mm). The measured translational and rotational errors were used to calculate the dose using two positioning strategies: an off-line and an on-line protocol to correct the translational shifts. The estimated dose to the targets and the organs at risk was compared with the intended dose. Results: Residual deviations after off-line correction led to statistically significant, but very small, reductions in dose coverage. Even when a 2-mm margin was used, the average reduction in dose to 99% of the volume was 1.4 {+-} 1.9 Gy for the tumor, 1.5 {+-} 1.5 Gy for the prostate without seminal vesicles (boost volume), and 4.3 {+-} 4.6 Gy, including the seminal vesicles (clinical target volume). Patients with large systematic rotational errors demonstrated a substantial decrease in dose, especially for the clinical target volume. If an on-line correction protocol was used, the average mean dose and dose to 99% of the volume of the targets improved. However, the extensive dose reduction for patients with large rotational errors barely recovered with on-line correction. Conclusion: For complex prostate IMRT with an integrated tumor boost, the use of an on-line correction protocol yields little improvement without the correction of rotational errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Frequency dispersion of the first hyperpolarizabilities of reference molecules for nonlinear optics

The frequency dispersion of the hyper-Rayleigh scattering first hyperpolarizabilities (β{sub HRS}) of five reference molecules for nonlinear optics, namely, carbon tetrachloride, chloroform, dichloromethane, acetonitrile, and trichloroacetonitrile, is described using the coupled-cluster singles and doubles quadratic response function (CCSD-QRF) as well as approximate schemes. Comparisons to approximate schemes in which the frequency dispersion is evaluated as either a multiplicative or an additive correction to the static hyperpolarizability yield the following observations: (i) errors of the order of 10% or less are usually encountered when using the multiplicative scheme for photon energies far from the lowest dipole-allowed excitation energies, (ii) spurious cases cannot be excluded as evidenced by carbon tetrachloride where the multiplicative scheme predicts a decrease of β{sub HRS} in contradiction to the increase obtained using the CCSD-QRF method, and (iii) the additive scheme is at best as reliable as the multiplicative approximation. The two-state approximation presents the advantage of correcting the wrong behavior of the additive and multiplicative schemes for carbon tetrachloride, but it is not an improved solution for the other compounds, while the question of selecting the appropriate dominant excited state remains unanswered. Finally, a new β{sub xyz} value of 18.9 a.u. is proposed for carbon tetrachloride in gas phase at λ = 1064 nm, to be compared with the measured 16.9 ± 1.4 a.u. value due to Shelton.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pinning Susceptibility: The Effect of Dilute, Quenched Disorder on Jamming

Here, we study the effect of dilute pinning on the jamming transition. Pinning reduces the average contact number needed to jam unpinned particles and shifts the jamming threshold to lower densities, leading to a pinning susceptibility, χ p . Our main results are that this susceptibility obeys scaling form and diverges in the thermodynamic limit as χ p ∝ | φ - φ c ∞ | - γ p where φ c ∞ is the jamming threshold in the absence of pins. Finite-size scaling arguments yield these values with associated statistical (systematic) errors γ p = 1.018 ± 0.026 ( 0.291 ) in d = 2 and γ p = 1.534 ± 0.120 ( 0.822 ) in d = 3 . Logarithmic corrections raise the exponent in d = 2 to close to the d = 3 value, while the systematic errors are very large.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Environmental influences on autocollimator-based angle and form metrology

Deflectometric profilometers are indispensable tools for the precision form measurement of beam-shaping optics of synchrotrons and x-ray free electron lasers. They are used in metrology labs for x-ray optics worldwide and are crucial for providing measurement accuracy dictated by the form tolerances for modern state-of-the-art x-ray optics. Deflectometric profilometers use surface slope (angle) to assess form, and they utilize commercial autocollimators for the contactless slope measurement. In this contribution, we discuss the influences of environmental parameters, such as temperature and air pressure, including their gradients, on high-accuracy metrology with autocollimators in profilometers. They can cause substantial systematic errors in form measurement, especially in the case of large and strongly curved optical surfaces of high dynamic range. Relative angle and form measuring errors of the order of 10 -4 are to be expected. We characterize environmental influences by extended theoretical and experimental investigations and derive strategies for correcting them. Additionally, we report on the possibility to minimize the contributions of some errors by the application of sophisticated experimental arrangements and methods. We aim at approaching fundamental limits in autocollimator-based slope and form metrology.

47 OTHER INSTRUMENTATION↗

Sensitivity of Cloud-Radiative Effects to Cloud Fraction Parametrizations in Tropical, Mid-Latitude and Arctic Kilometre-Scale Simulations

The Regional Atmosphere (RA) configuration of the Met Office Unified Model currently requires different cloud fraction parametrizations (CFP) for tropical and midlatitude simulations. To explore the scope for unification of these two RA configurations, this paper presents a detailed evaluation of simulations over tropical, midlatitude and arctic domains, with two different diagnostic CFPs, a prognostic CFP, and no CFP at all. Furthermore, a novel, hybrid approach was used that treats liquid cloud diagnostically and ice cloud prognostically. Using observations from three U.S. Department of Energy Atmospheric Radiation Measurement supersites, it is shown that none of these CFPs stands out as superior over all domains. Over the frequently overcast Arctic, the all-or-nothing approach best captures the cloud radiative properties. Conversely, CFPs are of benefit in regions with frequent partial cloudiness, such as the midlatitudes and the tropics. However, their improved cloud radiative properties often hide an error compensation. All models underestimate overcast, low-base cloud with small water paths in convective environments. In addition, mid-latitude overcast, low-base, optically thick clouds in the morning, possibly associated with overnight convection, are frequently too broken. Diagnostic schemes compensate for these errors by producing spurious, scattered afternoon cloud, which could be due to a correct cloud response to too eager convective initiation. Winter clouds over the midlatitudes are improved when liquid cloud is represented diagnostically with a bimodal saturation-departure PDF, without error compensation. While it is difficult to unify the RA across the globe around a single CFP scheme, the newly proposed Hybrid scheme performs reasonably well for cloud cover across all regions. It also exhibits SW biases that are smaller than most other configurations and is less affected by excessive liquid water paths and compensating errors than fully diagnostic schemes. Surface precipitation is fairly insensitive to the CFP in the simulations shown here.

54 ENVIRONMENTAL SCIENCES↗

Surface mass balance contributions to acceleration of Antarctic ice mass loss during 2003-2013: ANTARCTIC ICE MASS LOSS ACCELERATION

Recent observations from satellite gravimetry (the Gravity Recovery and Climate Experiment (GRACE) mission) suggest an acceleration of ice mass loss from the Antarctic Ice Sheet (AIS). The contribution of surface mass balance changes (due to variable precipitation) is compared with GRACE-derived mass loss acceleration by assessing the estimated contribution of snow mass from meteorological reanalysis data. We find that over much of the continent, the acceleration can be explained by precipitation anomalies. However, on the Antarctic Peninsula and other parts of West Antarctica, mass changes are not explained by precipitation and are likely associated with ice discharge rate increases. The total apparent GRACE acceleration over all of the AIS between 2003 and 2013 is -13.6 ± 7.2 Gt/yr2 . Of this total, we find that the surface mass balance component is -8.2 ± 2.0 Gt/yr2 . However, the GRACE estimate appears to contain errors arising from the atmospheric pressure fields used to remove air mass effects. The estimated acceleration error from this effect is about 9.8 ± 5.8 Gt/yr2 . Correcting for this yields an ice discharge acceleration of -15.1 ± 6.5 Gt/yr2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗