Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Theoretical position-velocity diagrams of flux, electron density, and electron temperature in Herbig-Haro objects

Many features of Herbig-Haro objects can be reproduced using a kinematical bow shock model. We use the model to generate position-velocity (PV) diagrams of flux in H-alpha (O I) lambda lambda 6300+63, (S II) lambda lambda 6716+31, (O III) lambda lambda 4959+5007, and (C I) lambda lambda 9823+50, line ratios of (O I)/H-alpha, (O I)/(S II), (S II)/H-alpha, H-alpha(S II), and (O III)/H-alpha, electron density N(sub e), and electron temperature T(sub e). We show how position-velocity diagrams of N(sub e) and flux vary with shock velocity. By matching the diagrams from single lines, the line ratios, and N(sub e) with observations, we determined a narrow range of shock parameters for HH 1F, 2(A' + H), and 43 (B + C). We model the N(sub e) features of HH 2(A' + H) as a superposition of two bowshocks. We also show that the effects of slight misalignments of the two diagrams to be divided can produce artifacts in the line ratios and N(sub e) which obliterate the physical features. We show that N(sub e) in HH 1 can only be explained using the kinematical model by taking these misalignments into account.

Indebetouw, Remy↗

Electronic-To-Optical-To-Electronic Packet-Data Conversion

Space-time multiplexer (STM) cell-based communication system designed to take advantage of both high throughput attainable in optical transmission links and flexibility and functionality of electronic processing, storage, and switching. Long packets segmented and transmitted optically by wavelength-division multiplexing. Performs optoelectronic and protocol conversion between electronic "store-and-forward" protocols and optical "hot-potato" protocols.

Monacos, Steve↗

X-Ray Microanalysis and Electron Energy Loss Spectrometry in the Analytical Electron Microscope: Review and Future Directions

This paper reviews and discusses future directions in analytical electron microscopy for microchemical analysis using X-ray and Electron Energy Loss Spectroscopy (EELS). The technique of X-ray microanalysis, using the ratio method and k(sub AB) factors, is outlined. The X-ray absorption correction is the major barrier to the objective of obtaining I% accuracy and precision in analysis. Spatial resolution and Minimum Detectability Limits (MDL) are considered with present limitations of spatial resolution in the 2 to 3 microns range and of MDL in the 0.1 to 0.2 wt. % range when a Field Emission Gun (FEG) system is used. Future directions of X-ray analysis include improvement in X-ray spatial resolution to the I to 2 microns range and MDL as low as 0.01 wt. %. With these improvements the detection of single atoms in the analysis volume will be possible. Other future improvements include the use of clean room techniques for thin specimen preparation, quantification available at the I% accuracy and precision level with light element analysis quantification available at better than the 10% accuracy and precision level, the incorporation of a compact wavelength dispersive spectrometer to improve X-ray spectral resolution, light element analysis and MDL, and instrument improvements including source stability, on-line probe current measurements, stage stability, and computerized stage control. The paper reviews the EELS technique, recognizing that it has been slow to develop and still remains firmly in research laboratories rather than in applications laboratories. Consideration of microanalysis with core-loss edges is given along with a discussion of the limitations such as specimen thickness. Spatial resolution and MDL are considered, recognizing that single atom detection is already possible. Plasmon loss analysis is discussed as well as fine structure analysis. New techniques for energy-loss imaging are also summarized. Future directions in the EELS technique will be the development of new spectrometers and improvements in thin specimen preparation. The microanalysis technique needs to be simplified and software developed so that the EELS technique approaches the relative simplicity of the X-ray technique. Finally, one can expect major improvements in EELS imaging as data storage and processing improvements occur.

Goldstein, J. I.↗

Imaging Electron Spectrometer (IES) Electron Preprocessor (EPP) Design

The Aerospace Corporation developed the Electron PreProcessor (EPP) to support the Imaging Electron Spectrometer (IES) that is part of the RAPID experiment on the ESA/NASA CLUSTER mission. The purpose of the EPP is to collect raw data from the IES and perform processing and data compression on it before transferring it to the RAPID microprocessor system for formatting and transmission to the CLUSTER satellite data system. The report provides a short history of the RAPID and CLUSTER programs and describes the EPP design. Four EPP units were fabricated, tested, and delivered for the original CLUSTER program. These were destroyed during a launch failure. Four more EPP units were delivered for the CLUSTER II program. These were successfully launched and are operating nominally on orbit.

Fennell, J. F.↗

Nano-Electronics and Bio-Electronics

Viewgraph presentation on Nano-Electronics and Bio-Electronics is discussed. Topics discussed include: NASA Ames nanotechnology program, Potential Carbon Nanotube (CNT) application, CNT synthesis,Computational Nanotechnology, and protein nanotubes.

Srivastava, Deepak↗

Electron-He(+) P-wave Elastic Scattering and Photoabsorption in Two-electron Systems

In a previous paper [Bhatia, Phys. Rev. A 69,032714 (2004)], electron-hydrogen P-wave scattering phase shifts were calculated using the optical potential approach based on the Feshbach projection operator formalism. This method is now extended to the singlet and triplet electron-He(+) P-wave scattering in the elastic region. Phase shifts are calculated using Hylleraas-type correlation functions with up to 220 terms. Results are rigorous lower bounds to the exact phase shifts and they are compared to phase shifts obtained from the method of polarized orbitals and close-coupling calculations. The continuum functions calculated here are used to calculate photoabsorption cross sections. Photoionization cross sections of He and photodetachment cross sections of H(-) are calculated in the elastic region, i.e. leaving He(+) and H in their respective ground states, and compared with previous calculations. Radiative attachment rates are also calculated.

Bhatia, A. K.↗

Total Electron Scattering and Electronic State Excitations Cross Sections for O_2, CO, and CH_4

Available electron collision cross section data concerning total and elastic scattering, vibrationalexcitation, and ionization for O_2, CO, and CH_4 have been critically reviewed, and a set of crosssections for modeling of planetary atmospheric behavior is recommended. Utilizing theserecommended cross sections, we derived total electronic state excitation cross sections and upperlimits for dissociation cross sections, which in the case of CH_4 should very closely equal the actualdissociation cross section.

Kanik, I.↗

D-Wave Electron-H, -He+, and -Li2+ Elastic Scattering and Photoabsorption in P States of Two-Electron Systems

In previous papers [A. K. Bhatia, Phys. Rev. A 85, 052708 (2012); 86, 032709 (2012); 87, 042705 (2013)] electron-H, -He+, and -Li2+ P-wave scattering phase shifts were calculated using the variational polarized orbital theory. This method is now extended to the singlet and triplet D-wave scattering in the elastic region. The long-range correlations are included in the Schrodinger equation by using the method of polarized orbitals variationally. Phase shifts are compared to those obtained by other methods. The present calculation provides results which are rigorous lower bonds to the exact phase shifts. Using the presently calculated D-wave and previously calculated S-wave continuum functions, photoionization of singlet and triplet P states of He and Li+ are also calculated, along with the radiative recombination rate coefficients at various electron temperatures.

D-wave↗

Hall2De Simulations with a First-Principles Electron Transport Model Based on the Electron Cyclotron Drift Instability

Several years of work have combined plasma measurements in a laboratory Hall thruster and r-z numerical simulations with Hall2De to isolate the spatial variation of the anomalous collision frequency needed in Ohm’s law to produce the observed thruster behavior. This numerical solution is used here to test the validity of a first-principles model of the anomalous transport in these devices before such model is implemented self-consistently in r-z fluid codes like Hall2De. The first-principles model employs quasi-linear theory and is based on the hypothesis that the Electron Cyclotron Drift Instability (ECDI) excites ion acoustic turbulence that, in turn, enhances the effective collision frequency in these devices. We find that a model of the ECDI that assumes Maxwellian velocity distributions for electrons and singly-charged, main-beam, cold ions (Ti=0.07 eV) is insufficient to explain the expected variation of the anomalous collision frequency both in the interior and exterior of the acceleration channel. When warm ions (~0.5-3 eV) are accounted for, the ECDI model in the channel interior appears more promising but fails by orders of magnitude in the near plume region due to the much higher Landau damping of the ion acoustic waves there. This implies that either (a) some process allows the ECDI instability to remain uninhibited by classical Landau damping or, (b) that a different instability (or instabilities) altogether, also insusceptible to Landau damping, is/are active in this region. A previous hypothesis, that convection of wave energy generated by the ECDI in the channel plays a significant role in the near plume, is not supported by the results of the simulations.

Mikellides, Ioannis G.↗

A First-Principles Model Based on Saturation of the Electron Cyclotron Drift Instability for Electron Transport in Hydrodynamics Simulations of Hall Thruster Plasmas

We present a computational model based on the hypothesis that the higher-than-expected electron mobility across magnetic field lines observed in Hall thrusters is due to the growth and eventual saturation of the electron cyclotron drift instability. The key improvement of this model with respect to previous work is that it decouples the saturation of the instability from the correlation that exists between mobility and magnitude of the wave perturbations in linear theory, thereby enabling first-principles simulations. The model has been incorporated in the 2-D (r-z) multi-fluids code Hall2De and simulations of the H6 thruster at 300 V, 20 A are numerically stable and achieve a steady-state solution at a computational cost that is not significantly higher than previous Hall2De simulations. The computed location of the acceleration region is found to be within 10% of the length of the acceleration channel compared to that inferred by experiments. The simulations also capture well the plasma gradients along the channel centerline of this thruster. To further establish the validity of this model, we plan to conduct simulations of other thrusters and/or operating conditions.

Lopez Ortega, Alejandro↗

Electron gun for a multiple beam klystron with magnetic compression of the electron beams

A multi-beam electron gun provides a plurality N of cathode assemblies comprising a cathode, anode, and focus electrode, each cathode assembly having a local cathode axis and also a central cathode point defined by the intersection of the local cathode axis with the emitting surface of the cathode. Each cathode is arranged with its central point positioned in a plane orthogonal to a device central axis, with each cathode central point an equal distance from the device axis and with an included angle of 360/N between each cathode central point. The local axis of each cathode has a cathode divergence angle with respect to the central axis which is set such that the diverging magnetic field from a solenoidal coil is less than 5 degrees with respect to the projection of the local cathode axis onto a cathode reference plane formed by the device axis and the central cathode point, and the local axis of each cathode is also set such that the angle formed between the cathode reference plane and the local cathode axis results in minimum spiraling in the path of the electron beams in a homogenous magnetic field region of the solenoidal field generator.

47 OTHER INSTRUMENTATION↗

Cooled electronic system with liquid-cooled cold plate and thermal spreader coupled to electronic component

Apparatus and method are provided for facilitating cooling of an electronic component. The apparatus includes a liquid-cooled cold plate and a thermal spreader associated with the cold plate. The cold plate includes multiple coolant-carrying channel sections extending within the cold plate, and a thermal conduction surface with a larger surface area than a surface area of the component to be cooled. The thermal spreader includes one or more heat pipes including multiple heat pipe sections. One or more heat pipe sections are partially aligned to a first region of the cold plate, that is, where aligned to the surface to be cooled, and partially aligned to a second region of the cold plate, which is outside the first region. The one or more heat pipes facilitate distribution of heat from the electronic component to coolant-carrying channel sections of the cold plate located in the second region of the cold plate.

36 MATERIALS SCIENCE↗

Cooled electronic system with liquid-cooled cold plate and thermal spreader coupled to electronic component

Apparatus and method are provided for facilitating cooling of an electronic component. The apparatus includes a liquid-cooled cold plate and a thermal spreader associated with the cold plate. The cold plate includes multiple coolant-carrying channel sections extending within the cold plate, and a thermal conduction surface with a larger surface area than a surface area of the component to be cooled. The thermal spreader includes one or more heat pipes including multiple heat pipe sections. One or more heat pipe sections are partially aligned to a first region of the cold plate, that is, where aligned to the surface to be cooled, and partially aligned to a second region of the cold plate, which is outside the first region. The one or more heat pipes facilitate distribution of heat from the electronic component to coolant-carrying channel sections of the cold plate located in the second region of the cold plate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooled electronic system with liquid-cooled cold plate and thermal spreader coupled to electronic component

Apparatus and method are provided for facilitating cooling of an electronic component. The apparatus includes a liquid-cooled cold plate and a thermal spreader associated with the cold plate. The cold plate includes multiple coolant-carrying channel sections extending within the cold plate, and a thermal conduction surface with a larger surface area than a surface area of the component to be cooled. The thermal spreader includes one or more heat pipes including multiple heat pipe sections. One or more heat pipe sections are partially aligned to a first region of the cold plate, that is, where aligned to the surface to be cooled, and partially aligned to a second region of the cold plate, which is outside the first region. The one or more heat pipes facilitate distribution of heat from the electronic component to coolant-carrying channel sections of the cold plate located in the second region of the cold plate.

Chainer, Timothy J.↗

Enhanced neutron detector and electron amplifier structure and a method of fabricating the enhanced neutron detector and electron amplifier structure

An enhanced electron amplifier structure includes a substrate configured to amplify a signal of an incident particle by causing a cascade of secondary electron emissions and an enhancement layer configured to increase a sensitivity of the substrate to the incident particle. The enhancement layer is provided on an upper surface of the substrate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-Shot Diagnostics of Microbunched Electrons in Laser-Driven Plasma Accelerators and Free-Electron Lasers

In general, the inherent statistical variances in the laser-driven plasma accelerators (LPAs) and self-amplified spontaneous emission (SASE) free electron lasers (FELs) motivate the use of single-shot diagnostics. In addition, the microbunching phenomenon in each is also variable, so coherent optical transition radiation (COTR) techniques also warrant single-shot evaluations. In both cases, the enhancements of the signals enable optical beam splitters to be used to direct light to the different measuring devices for electron beam size, divergence, spectral content, and/or bunch length as appropriate. COTR Interferometry (COTRI) modelling results for the pre-buncher case at 266 nm and for the LPA case at 633 nm are presented. In addition, examples of few-micron beam size and sub-mrad beam divergence measurements from a single shot of an LPA are reported.

43 PARTICLE ACCELERATORS↗

Flexible and stretchable electronic systems for epidermal electronics

Provided herein are skin-mounted biomedical devices and methods of making and using biomedical devices for sensing and actuation applications. For example, flexible and/or stretchable biomedical devices are provided, including electronic devices useful for establishing conformal contact with the skin of a subject. Devices disclosed herein can comprise a plurality of sensing and/or actuating devices provided as part of a skin-mounted flexible or stretchable electronic circuit.

36 MATERIALS SCIENCE↗

Enhanced electron amplifier structure and method of fabricating the enhanced electron amplifier structure

An enhanced electron amplifier structure includes a microporous substrate having a front surface and a rear surface, the microporous substrate including at least one channel extending substantially through the substrate between the front surface and the rear surface, an ion diffusion layer formed on a surface of the channel, the ion diffusion layer comprising a metal oxide, a resistive coating layer formed on the first ion diffusion layer, an emissive coating layer formed on the resistive coating layer, and an optional ion feedback layer formed on the front surface of the structure. The emissive coating produces a secondary electron emission responsive to an interaction with a particle received by the channel. The ion diffusion layer, the resistive coating layer, the emissive coating layer, and the ion feedback layer are independently deposited via chemical vapor deposition or atomic layer deposition.

Mane, Anil U.↗