Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diameter distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

X-ray radiography of cavitation in a beryllium alloy nozzle

In this study, making quantitative measurements of the vapor distribution in a cavitating nozzle is difficult, owing to the strong scattering of visible light at gas–liquid boundaries and wall boundaries, and the small lengths and time scales involved. The transparent models required for optical experiments are also limited in terms of maximum pressure and operating life. Over the past few years, x-ray radiography experiments at Argonne’s Advanced Photon Source have demonstrated the ability to perform quantitative measurements of the line of sight projected vapor fraction in submerged, cavitating plastic nozzles. In this paper, we present the results of new radiography experiments performed on a submerged beryllium nozzle which is 520 μm in diameter, with a length/diameter ratio of 6. Beryllium is a light, hard metal that is very transparent to x-rays due to its low atomic number. We present quantitative measurements of cavitation vapor distribution conducted over a range of non-dimensional cavitation and Reynolds numbers, up to values typical of gasoline and diesel fuel injectors. A novel aspect of this work is the ability to quantitatively measure the area contraction along the nozzle with high spatial resolution. Analysis of the vapor distribution, area contraction and discharge coefficients are made between the beryllium nozzle and plastic nozzles of the same nominal geometry. When gas is dissolved in the fuel, the vapor distribution can be quite different from that found in plastic nozzles of the same dimensions, although the discharge coefficients are unaffected. In the beryllium nozzle, there were substantially fewer machining defects to act as nucleation sites for the precipitation of bubbles from dissolved gases in the fuel, and as such the effect on the vapor distribution was greatly reduced.

36 MATERIALS SCIENCE↗

The absolute magnitude distribution of Kuiper Belt objects

Here we measure the absolute magnitude distributions (H-distribution) of the dynamically excited and quiescent (hot and cold) Kuiper Belt objects (KBOs), and test if they share the same H-distribution as the Jupiter Trojans. From a compilation of all useable ecliptic surveys, we find that the KBO H-distributions are well described by broken power laws. The cold population has a bright-end slope, α{sub 1}=1.5{sub −0.2}{sup +0.4}, and break magnitude, H{sub B}=6.9{sub −0.2}{sup +0.1} (r'-band). The hot population has a shallower bright-end slope of, α{sub 1}=0.87{sub −0.2}{sup +0.07}, and break magnitude H{sub B}=7.7{sub −0.5}{sup +1.0}. Both populations share similar faint-end slopes of α{sub 2} ∼ 0.2. We estimate the masses of the hot and cold populations are ∼0.01 and ∼3 × 10{sup –4} M {sub ⊕}. The broken power-law fit to the Trojan H-distribution has α{sub 1} = 1.0 ± 0.2, α{sub 2} = 0.36 ± 0.01, and H {sub B} = 8.3. The Kolmogorov-Smirnov test reveals that the probability that the Trojans and cold KBOs share the same parent H-distribution is less than 1 in 1000. When the bimodal albedo distribution of the hot objects is accounted for, there is no evidence that the H-distributions of the Trojans and hot KBOs differ. Our findings are in agreement with the predictions of the Nice model in terms of both mass and H-distribution of the hot and Trojan populations. Wide-field survey data suggest that the brightest few hot objects, with H{sub r{sup ′}}≲3, do not fall on the steep power-law slope of fainter hot objects. Under the standard hierarchical model of planetesimal formation, it is difficult to account for the similar break diameters of the hot and cold populations given the low mass of the cold belt.

79 ASTRONOMY AND ASTROPHYSICS↗

Parametric analysis of hollow conductor parallel and coaxial transmission lines for high frequency space power distribution

A parametric analysis was performed of transmission cables for transmitting electrical power at high voltage (up to 1000 V) and high frequency (10 to 30 kHz) for high power (100 kW or more) space missions. Large diameter (5 to 30 mm) hollow conductors were considered in closely spaced coaxial configurations and in parallel lines. Formulas were derived to calculate inductance and resistance for these conductors. Curves of cable conductance, mass, inductance, capacitance, resistance, power loss, and temperature were plotted for various conductor diameters, conductor thickness, and alternating current frequencies. An example 5 mm diameter coaxial cable with 0.5 mm conductor thickness was calculated to transmit 100 kW at 1000 Vac, 50 m with a power loss of 1900 W, an inductance of 1.45 micron and a capacitance of 0.07 micron-F. The computer programs written for this analysis are listed in the appendix.

Jeffries, K. S.↗

The size distribution of the earth-approaching asteroids

The discovery circumstances of the first asteroids ever observed outside the earth's atmosphere but within the neighborhood of the earth-moon system are described. Four natural objects with diameters in the range 5-50 m were detected during a search for earth-approaching asteroids conducted each month at the 0.91-m Spacewatch Telescope at Kitt Peak. An additional 19 earth approachers with sizes in the range 50 m to 5 km were discovered. These obervations determine the cumulative flux of asteroids near earth as a function of absolute magnitude. For asteroids larger than about 100 m, a power-law dependence with exponent of about 0.9 is observed, consistent with their evolution from the main-belt population. At about 10 m, the flux is more than two orders of magnitude greater than this power-law extrapolation.

Rabinowitz, D. L.↗

SU-F-T-184: 3D Range-Modulator for Scanned Particle Therapy: Development, Monte Carlo Simulations and Measurements

Purpose: Active raster scanning in particle therapy results in highly conformal dose distributions. Treatment time, however, is relatively high due to the large number of different iso-energy layers used. By using only one energy and the so called 3D range-modulator irradiation times of a few seconds only can be achieved, thus making delivery of homogeneous dose to moving targets (e.g. lung cancer) more reliable. Methods: A 3D range-modulator consisting of many pins with base area of 2.25 mm2 and different lengths was developed and manufactured with rapid prototyping technique. The form of the 3D range-modulator was optimised for a spherical target volume with 5 cm diameter placed at 25 cm in a water phantom. Monte Carlo simulations using the FLUKA package were carried out to evaluate the modulating effect of the 3D range-modulator and simulate the resulting dose distribution. The fine and complicated contour form of the 3D range-modulator was taken into account by a specially programmed user routine. Additionally FLUKA was extended with the capability of intensity modulated scanning. To verify the simulation results dose measurements were carried out at the Heidelberg Ion Therapy Center (HIT) with a 400.41 MeV 12C beam. Results: The high resolution measurements show that the 3D range-modulator is capable of producing homogeneous 3D conformal dose distributions, simultaneously reducing significantly irradiation time. Measured dose is in very good agreement with the previously conducted FLUKA simulations, where slight differences were traced back to minor manufacturing deviations from the perfect optimised form. Conclusion: Combined with the advantages of very short treatment time the 3D range-modulator could be an alternative to treat small to medium sized tumours (e.g. lung metastasis) with the same conformity as full raster-scanning treatment. Further simulations and measurements of more complex cases will be conducted to investigate the full potential of the 3D range-modulator.

60 APPLIED LIFE SCIENCES↗

Size-segregated emissions and metal content of vehicle-emitted particles as a function of mileage: Implications to population exposure

The study aims at investigating the characteristics (size distribution, active surface and metal content) of particles emitted by cars as a function of mileage using a novel methodology for characterizing particulate emissions captured by Exhaust Gas Suspension (EGS). EGS was obtained by passing the exhaust gases through a container of deionized water. EGS analysis was performed using laser granulometry, electron scanning microscopy, and high resolution mass spectrometry. Implications of the differences in key features of the emitted particles on population exposure were investigated using numerical simulation for estimating size-segregated PM deposition across human respiratory tract (HRT). It was found that vehicle mileage, age and the respective emissions class have almost no effect on the size distribution of the exhaust gas particulate released into the environment; about half of the examined vehicles with low mileage were found to release particles of aerodynamic diameter above 10 μm. The exhaust gas particulate detected in the EGS of all cars can be classified into three major size classes: (1) 0.1–5 µm – soot and ash particles, metals (Au, Pt, Pd, Ir); (2) 10–30 µm – metal (Cr, Fe, Cu, Zr, Ni) and ash particles; (3) 400–1,000 µm – metal (Fe, Cr, Pb) and ash particles. Newer vehicles with low mileage are substantial sources of soot and metal particles with median diameter of 200 nm with a higher surface area (up to 89,871.16 cm{sup 2}/cm{sup 3}). These tend to deposit in the lower part of the human respiratory tract. - Highlights: • Car mileage has virtually no effect on the size of the solid particles released. • Newer diesel vehicles emit particles of lower aerodynamic diameter. • Particle active surface emitted by newer vehicles is on average 3 times higher. • Real-life emissions were translated into actual internal PM exposure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microstructural characterization of SiO2/Ni nanocomposites electrodeposited from a sulphate bath modified by PEI

Highlights: • SiO{sub 2}/Ni + PEI nanocomposites are deposited from the sulphate bath containing PEI. • PEI allows incorporation of higher SiO{sub 2} vol% in SiO{sub 2}/Ni + PEI nanocomposites. • PEI in the form of a thin layer surrounds spherical Ni nanograins and SiO{sub 2} clusters. • PEI action ensures high hardness, tribological properties and corrosion resistance. - Abstract: SiO{sub 2}/Ni nanocomposite coatings containing well-dispersed SiO{sub 2} nanoparticles were electrodeposited from a sulphate bath with and without the addition of polyethylenimine (PEI) as a cationic surfactant. The surface morphology and microstructure in the cross-sections of the deposited nanocomposites were examined by scanning electron microscopy. More detailed microstructure characterization was performed using transmission, scanning-transmission and high resolution transmission electron microscopy. It was determined that the addition of 0.05 g/L and 0.1 g/L of PEI allows the incorporation of SiO{sub 2} nanoparticles in the nickel matrix to be increased in comparison with the nanocomposite deposited without a surfactant. Based on high spatial resolution microanalysis, performed using high count rate energy dispersive spectroscopy of characteristic X-rays in the scanning-transmission mode, the distribution of SiO{sub 2} nanoparticles in the nanocomposite was visualized on elemental maps. Image analysis of the electron microscopy images enabled the mean equivalent circle diameters of grains in the nickel matrix to be determined, together with the volume fraction of SiO{sub 2} nanoparticles in the nanocomposites. The volume fraction of SiO{sub 2} clusters in the SiO{sub 2}/Ni + PEI nanocomposites with the addition of 0.05 g/L and 0.1 g/L of PEI is equal to 18.4% and 13.3%, respectively. Furthermore, the PEI addition allows the nickel grain size in the matrix to be reduced. The combination of different imaging techniques confirmed that PEI is not only present as a surfactant in the electrolytic bath, but also incorporates into the microstructure of the nanocomposite. Nanocomposites electrodeposited in the presence of 0.05 g/L of PEI exhibit higher hardness, good tribological properties and improved corrosion resistance. Although increasing the PEI concentration in the bath up to 0.1 g/L strongly promotes grain size reduction and increase of the SiO{sub 2} volume fraction, it also causes an increase in the PEI fraction embedded in the microstructure, which results in deterioration of the properties of the SiO{sub 2}/Ni + PEI nanocomposites.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Absorption Correction for Reliable Pair Distribution Functions from Low Energy X-ray Sources

This paper explores the development and testing of a simple absorption correction model for processing powder X-ray diffraction data from Debye−Scherrer geometry laboratory X-ray experiments. This may be used as a preprocessing step before using PDFGETX3 to obtain reliable pair distribution functions (PDFs). Various experimental and theoretical methods for estimating μR were explored, and the most appropriate μR values for correction were identified for different capillary diameters and X-ray beam sizes. We identify operational ranges of μR where a reasonable signal-to-noise ratio is possible after correction. A user-friendly software package, DIFFPY.LABPDFPROC, is presented that can help estimate μR and perform absorption corrections with a rapid calculation for efficient processing.

Absorption↗

A simple hard x-ray ''nanoslit'' for measuring wavefront intensity

A new method is proposed for nanoscale hard x-ray measurements. This method uses a reflection on a heavy-metal wire that functions as a single slit with a nanoscale aperture for a parallel x-ray beam. This ''nanoslit'' can be used to perform high-spatial-resolution measurements of the intensity distribution of a wavefront that diverges from an aperture. In experiments, Fresnel fringes generated by a rectangular aperture were measured using a 300-{mu}m-diameter platinum wire as the nanoslit. In these experiments, the finest fringes with a period of 26 nm could be successfully resolved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanocluster production for solar cell applications

This research focuses on the fabrication and characterization of silver (Ag) and silicon (Si) nanoclusters that might be used for solar cell applications. Silver and silicon nanoclusters have been synthesized by means of dc magnetron sputtering and inert gas condensation inside an ultra-high vacuum compatible system. We have found that nanocluster size distributions can be tuned by various source parameters, such as the sputtering discharge power, flow rate of argon inert gas, and aggregation length. Quadrupole mass filter and transmission electron microscopy were used to evaluate the size distribution of Ag and Si nanoclusters. Ag nanoclusters with average size in the range of 3.6–8.3 nm were synthesized (herein size refers to the nanocluster diameter), whereas Si nanoclusters' average size was controlled to range between 2.9 and 7.4 nm by controlling the source parameters. This work illustrates the ability of controlling the Si and Ag nanoclusters' sizes by proper optimization of the operation conditions. By controlling nanoclusters' sizes, one can alter their surface properties to suit the need to enhance solar cell efficiency. Herein, Ag nanoclusters were deposited on commercial polycrystalline solar cells. Short circuit current (I{sub SC}), open circuit voltage (V{sub OC}), fill factor, and efficiency (η) were obtained under light source with an intensity of 30 mW/cm{sup 2}. A 22.7% enhancement in solar cell efficiency could be measured after deposition of Ag nanoclusters, which demonstrates that Ag nanoclusters generated in this work are useful to enhance solar cell efficiency.

36 MATERIALS SCIENCE↗

Ultrashort XUV pulse absorption spectroscopy of partially oxidized cobalt nanoparticles

High-order harmonic generation (HHG) based transient extreme ultraviolet (XUV) absorption spectroscopy is an emerging technique to trace photoinduced charge carrier dynamics in condensed phase materials with femtosecond and even attosecond temporal resolution and elemental specificity. However, its application to nanoparticulate samples that are relevant, for example, for novel photocatalytic light harvesting concepts, has been limited. This is in part due to the challenge to produce residual-free samples on ultrathin, XUV-transparent substrates as well as a widespread understanding that sparsely distributed nanoparticles do not provide sufficient contrast for XUV absorption measurements. Here, we present static XUV absorption spectra of partially oxidized Co nanowire-structures with diameters of approximately 4.5 nm and lengths between 10 and 40 nm, recorded with an ultrashort pulse HHG light source. Nanoparticles are synthesized by the agglomeration of Co atoms inside superfluid helium droplets, followed by surface deposition and oxidation in ambient air. The method is uniquely suited for residual-free synthesis of transition metal nanowires and their deposition on ultrathin substrates. Analysis by high-resolution transmission electron microscopy reveals the formation of CoO nanowires with regions of unoxidized Co in their interior. The nanoparticle samples are investigated in an HHG-driven ultrafast XUV absorption setup. Despite the low surface coverage of only 23%, the recorded spectrum exhibits a distinct absorption feature at the Co M 2,3 (2p) edge near 60 eV with a peak height of about 40 mOD. Finally, the results support the feasibility of table-top ultrafast transient XUV absorption studies of photoinduced dynamics in transition metal oxide nanoparticles with sub-monolayer surface coverage.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effect of Approach Speed and Electrode Geometry on Electrostatic Discharges Off Floating Dielectrics

With the damaging effects of electrostatic discharges (ESDs), it is important to study them within various parameter regimes relevant to real-world scenarios. One such scenario studied here is a floating dielectric with no nearby ground plane with a grounded object approaching at a high rate of speed. One may encounter this scenario when moving objects by hand. Discharge current and radiated fields are captured for discharges drawn from polytetrafluoroethylene (PTFE) and poly methyl methacrylate (PMMA) with approach speeds ranging from 20 to 100 mm/s. Previous studies have shown that at lower speeds in metal-to-metal or metal-to-ground backed dielectric geometries, the peak current and discharge distance decrease with increasing speed. However, in the speed range studied here, an increase in distance and current are observed for increasing speed. Namely, the highest speeds coincide with the highest peak currents and discharge distances of approximately 800 mA and up to 24 mm. Further, with no grounded backing, as opposed to setups in other ESD studies, the electric field between the dielectric and an approaching electrode has a more uniform distribution with highest fields at the electrode, which is elucidated to be the driving factor in the differences revealed in this study. Two spheres of differing diameters and a conical electrode are used to draw discharges off the dielectric surfaces. Captured radiated fields via B-dot sensor, plasma imagery via intesified charge-coupled device (ICCD), and mapping of surface potential reveal that a majority of the energy lost during a discharge goes to gas losses and radiated fields.

36 MATERIALS SCIENCE↗

Scaling of EPR spectral-spatial images with size of sample: Images of a sample greater than 5 cm in linear dimension

The authors have obtained spectral-spatial EPR images of a phantom significantly larger than those previously obtained. Images of a homogeneous phantom 4.2 cm in diameter and 6.5 cm in length with B{sub 1} equivalent to that used for smaller samples give a similar linewidth resolution both with linewidth population distributions of width 0.1 {mu}T. Spatial resolution appeared to have modest degradation. Images of the large homogeneous phantom provide maps of the magnetic field of a partially shimmed magnet.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Arctic shrub root traits, northern Alaska, summer 2017 (Version 2.0)

This data package contains root trait data collected from 170 plots of rapidly expanding shrub genera (Alnus, Betula, and Salix) and a widespread sedge (Eriophorum vaginatum) along a latitudinal and temperature gradient in northern Alaska. The trait data were collected in July 2017 and include root architecture (root diameter and branching patterns), mycorrhizal colonization (%), nitrogen concentration (%), delta 15N (per mil), and vertical root biomass. These raw data support a submitted manuscript that examines the distribution and interspecific variations of absorptive root traits of shrubs and graminoids across the graminoid-dominated nutrient-poor arctic tundra and reveals how deciduous shrub expansion affects plant nutrient acquisition strategies in tundra ecosystems. Data are presented by site (n=5) and patch (shrub or sedge plot) in separate csv files. The location data are provided in the “plot coordinates” file; all other files contain the data in the file title. Detailed methods are in Chen et al. (2020).2023/07/20 Update: The latest version of this dataset publication is version 2.0. The latest version of the data package was updated to include the alder nodule biomass dataset (alder nodule biomass.csv) and associated metadata (metadata_alder nodule biomass.csv). The name of the previous metadata file was updated (metadata_ root traits and biomass.csv ) to distinguish it from the new metadata file.

54 ENVIRONMENTAL SCIENCES↗

Scanning Mobility Particle Sizer (SMPS)-Aerodynamic Particle Sizer (APS) Merged Size Distribution (mergedsmpsaps) Value-Added Product Report

Aerosol particles influence the Earth’s radiation balance directly by absorbing and scattering light and indirectly by influencing cloud formation, properties, and lifetimes. Measurements of aerosol particle optical properties, mass loading, size distributions, microphysical properties, cloud formation properties, and chemical composition are important for understanding the aerosol life cycle and for validating earth system models that predict these quantities. The Atmospheric Radiation Measurement (ARM) user facility’s Aerosol Observing System (AOS) is a highly instrumented platform designed to house instruments that measure many of these aerosol properties in situ. Currently, ARM operates at least four different instruments that measure a portion of the ambient aerosol size distribution. Most users are interested in the entire size distribution or a portion of the size distribution that extends across the measurement range of multiple instruments. However, merging these distributions is not trivial as the instruments employ different measurement principals and, in most cases, report data as a function of different representations of the aerosol diameter.

54 ENVIRONMENTAL SCIENCES↗

Instrumentation for the Investigation of Pitch Bearing Design and Reliability

Recently, there has been an increasing level of industry interest in pitch system and pitch bearing reliability. Pitch bearings are used in wind turbines to connect the blade root to the hub. Some populations of pitch bearings have demonstrated a 12% failure rate in 20 years. As rotor diameters continue to increase for tall land-based and offshore wind turbines, pitch bearings are becoming even larger in diameter, which can make them vulnerable to deflections and consequent stress concentrations. There is an increased need to more accurately study pitch bearing deformations, misalignment, load distributions, and contact stresses. A significant body of work has investigated fatigue lives and wear characteristics of pitch bearings on ground-based test rigs. NREL has also recently begun a research program related to pitch bearing reliability, recognizing its growing importance for wind turbines. The purpose of this paper is to describe a set of instrumentation that was recently installed on a 1.5 MW wind turbine at the NREL Flatirons Campus and provide an example data set. To the authors' knowledge, this will be the first publicly available pitch bearing data collection campaign on an operational wind turbine.

17 WIND ENERGY↗

Airborne far-infrared observations of the galactic center region

Maps of a region 10 arcmin in diameter around the galactic center made simultaneously in three wavelength bands at 30, 50, and 100 microns with about 1 arcmin resolution are presented, and the distribution of far-IR luminosity and color temperature across this region is derived. The position of highest far-IR surface brightness coincides with the peak of the late-type stellar distribution and with the H II region Sgr A West. The high spatial and temperature resolution of the data is used to identify features of the far-IR maps with known sources of near-IR, radio continuum, and molecular emission. The emission mechanism and energy sources for the far-IR radiation are analyzed qualitatively, and it is concluded that all of the observed far-IR radiation from the galactic-center region can be attributed to thermal emission from dust heated both by the late-type stars and by the ultraviolet sources which ionize the H II regions. A self-consistent model for the far-IR emission from the galactic-center region is presented. It is found that the visual extinction across the central 10 pc of the Galaxy is only about 3 mag and that the dust density is fairly uniform in this region. An upper limit of 10 million suns is set on the luminosity of any still unidentified source of 0.1- to 1-micron radiation at the galactic center.

Gatley, I.↗

Asymmetry of a circular jet observed in near and far fields

Turbulence intensity measurements were made in three different-size jets at various Mach numbers and the aerodynamic jet axis, defined as the locus of points in the flow at which the turbulence intensity is minimum, was determined. The deviations from the geometrical jet axis were on the order of 2-4% of the nozzle diameter, and the pure jet axis had the form of a helical wave. A similar asymmetry in the radiated noise was also noted. The measured circumferential distribution of rms fluctuating velocity signals confirmed the asymmetry of even a circular jet.

Yamamoto, K.↗