Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Chemosaturation Percutaneous Hepatic Perfusion (CS-PHP) with Melphalan: Evaluation of 2D-Perfusion Angiography (2D-PA) for Leakage Detection of the Venous Double-Balloon Catheter

Purpose: To evaluate the feasibility of 2D-perfusion angiography (2D-PA) for detecting leakage of the double-balloon catheter used for chemosaturation percutaneous hepatic perfusion (CS-PHP). Materials and Methods: Overall, 112 CS-PHP (09/2015-09/2018) in 52 patients were retrospectively screened for leakage alongside the double-balloon catheter on standard venograms. Finally, 18 procedures with visually detected leakage were included. Fifteen consecutive procedures without leakage served as control. To evaluate 2D-PA for leakage detection, the acquired digital subtraction venograms were post-processed. For each balloon, two different target ROIs were evaluated to assess a possible impact of localization and shape of the ROIs. Time to peak (TTP), peak density (PD), area under the curve (AUC), and ratios of target ROI/reference ROIs (PD{sub tROI}/PD{sub REF}; AUC{sub tROI}/AUC{sub REF}; and TTP{sub tROI}/TTP{sub REF}) were calculated. Results: Leakages were located as follows: 15/18 cranial and 3/18 caudal. At the cranial balloon both ROIs showed a significant decrease in PD{sub tROI}/PD{sub REF} and AUC{sub tROI}/AUC{sub REF} (ROI1: p < 0.0001; p < 0.0001; ROI2: p < 0.0001; p < 0.0001) and a significant increase in TTP{sub tROI}/TTP{sub REF} (ROI1: p = 0.0009; ROI2: p = 0.0003) after double-balloon correction. Following balloon adjustment, the 2D-PA ratios (PD and AUC) of the tested ROIs differed significantly (p < 0.05). The inter-individual comparison of the 2D-PA parameters of the group with leakage before balloon correction and the non-leakage group showed significantly different 2D-PA values for the cranial balloon in both ROIs (p < 0.05). No significant differences were found for the caudal balloon. Conclusion: 2D-PA provides a feasible tool for detecting leakages alongside the cranial portion of the double-balloon catheter used in CS-PHP. The shape and position of the ROIs used to assess perfusion and flow have an impact on the measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid systematic assessment of the detection and attribution of regional anthropogenic climate change

Despite being a well-established research field, the detection and attribution of observed climate change to anthropogenic forcing is not yet provided as a climate service. One reason for this is the lack of a methodology for performing tailored detection and attribution assessments on a rapid time scale. Here we develop such an approach, based on the translation of quantitative analysis into the “confidence” language employed in recent Assessment Reports of the Intergovernmental Panel on Climate Change. While its systematic nature necessarily ignores some nuances examined in detailed expert assessments, the approach nevertheless goes beyond most detection and attribution studies in considering contributors to building confidence such as errors in observational data products arising from sparse monitoring networks. When compared against recent expert assessments, the results of this approach closely match those of the existing assessments. Where there are small discrepancies, these variously reflect ambiguities in the details of what is being assessed, reveal nuances or limitations of the expert assessments, or indicate limitations of the accuracy of the sort of systematic approach employed here. Deployment of the method on 116 regional assessments of recent temperature and precipitation changes indicates that existing rules of thumb concerning the detectability of climate change ignore the full range of sources of uncertainty, most particularly the importance of adequate observational monitoring.

54 ENVIRONMENTAL SCIENCES↗

Transversely Excited Atmospheric CO{sub 2} Laser-Induced Plasma Spectroscopy for the Detection of Heavy Metals in Soil

A rapid detection of heavy metals in soil was presented by the metal-assisted gas plasma method using specific characteristics of a pulsed, transversely excited atmospheric (TEA) CO{sub 2} laser. The soil particles were placed in a hole made of acrylic plate. The sample was covered by a to prevent the soil particles from being blown off. The mesh also functioned to initiate a luminous plasma. When a TEA CO{sub 2} laser (1500 mJ, 200 ns) was focused on the soil sample, passing through the metal mesh, some of the laser energy was used to generate the gas plasma on the mesh surface, and the remaining laser energy was employed to ablate the soil particles. The fine, ablated soil particles moved into the gas plasma region to be dissociated and excited. Using this technique, analysis can be made with reduced sample pretreatment, and therefore a rapid analysis can be performed efficiently. The results proved that the signal to noise ratio (S/N) of the emission spectral lines is much better for the case of the present method (mesh method) compared to the case of standard laser-induced breakdown spectroscopy using the pellet method. Rapid detection of heavy metal elements in soil has been successfully carried out. The detection limits of Cu and Hg in soil were estimated to be 3 and 10 mg/kg, respectively. The present method has good potential for rapid and sensitive detection of heavy metals in soil samples.

54 ENVIRONMENTAL SCIENCES↗

Rapid Detection of Tetrodotoxin Using Surface-Enhanced Raman Spectroscopy and Fe{sub 3}O{sub 4}/SiO{sub 2}/Au Gold/Magnetic Nanoparticles

Fe{sub 3}O{sub 4} nanoparticles were first modified with tetraethoxylsilane to form Fe{sub 3}O{sub 4}/SiO{sub 2} nanoparticles, followed by the addition of 3-aminopropyltriethoxysilane and 3-thiolpropyltriethoxysilane to introduce –NH{sub 2} and –SH groups to the surface of Fe{sub 3}O{sub 4}/SiO{sub 2} nanoparticles. Gold nanoparticles were further assembled on the surface of Fe{sub 3}O{sub 4}/SiO{sub 2} via the electrostatic adsorption of –NH{sub 2} and the Au–S bond to produce stable core–shell Fe{sub 3}O{sub 4}/SiO{sub 2}/Au gold/magnetic nanoparticles. These Fe{sub 3}O{sub 4}/SiO{sub 2}/Au gold/magnetic nanoparticles were characterized by a variety of techniques such as transmission electron microscopy (TEM) and energy dispersive X-ray spectroscopy (EDX), and afterwards conjugated with tetrodotoxin antibodies (Ab) and used as a Raman active substrate (Fe{sub 3}O{sub 4}/SiO{sub 2}/Au–Ab) with Rhodamine B (RhB)-labeled tetrodotoxin antibody as a Raman reporter (Ab–RhB). Upon mixing these reagents with tetrodotoxin (TTX), a sandwich complex [Fe{sub 3}O{sub 4}/SiO{sub 2}/Au–Ab···TTX···Ab–RhB] was generated due to the specific antibody–antigen interactions. The immunocomplex was subsequently separated by an externally applied magnetic source and concentrated into a pellet point, where the laser interrogation of the pellet produced a strong signal characteristic of RhB. The logarithmic intensity of the signal was found to be proportional to the concentration of TTX with a limit of detection of 0.01 μg/mL and a detection linearity range of ~ 0.01–0.5 μg/mL. The established method eliminates the complicated procedures of traditional centrifuging, column separation, and incubation and achieves a rapid detection of tetrodotoxin with improved detection sensitivity.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

All-aerosol-jet-printed highly sensitive and selective polyaniline-based ammonia sensors: a route toward low-cost, low-power gas detection

In this work, we report the design and scalable fabrication of a low-cost and low-power polyaniline-based (PANI) ammonia (NH3) gas sensor on polyimide (PI) substrates using additive manufacturing techniques. The silver interdigitated electrode (IDE) arrays and conducting polymer films are printed onto PI using a direct-write technology of aerosol-jet printing. Morphological characteristics are examined by scanning electron microscopy and energy-dispersive X-ray analysis which reveal homogeneously printed PANI film on the IDE platform. The gas sensing performance is evaluated in the analytical early leak detection range of 5–1000 ppm NH3 in air as a function of both thermal (23 °C, 50 °C, 80 °C) and relative humidity (RH = 0%, 30%, 50%) exposures. The sensor exhibits sensitivity down to 5 ppm NH3 with a sub-ppm detection limit and good repeatability. We observe rapid NH3 detection at 0% RH with very extended times for equilibration and recovery. However, at both 30 and 50% RH, the room temperature response and recovery times are reduced to only about 1 min and 5 min, respectively. Experiments also reveal good sensitivity toward the analyte even at higher operating temperatures. Present results merit the practical application of aerosol-jet-printed, low-power sensors for industrial applications where low-level hazardous gas detection is essential.

36 MATERIALS SCIENCE↗

Exploring the Potential of Residual Impurities in Germanium Detectors for MeV-Scale Dark Matter Detection

Abstract The direct detection of MeV-scale dark matter (DM) particles hinges on achieving an exceptionally low-energy detection threshold. Germanium (Ge) detectors, meticulously tailored with precise impurity compositions, hold the potential to enhance sensitivity to energy levels below the sub-electronvolt (sub-eV) range. This study explores the behavior of residual impurities inherent to Ge detectors at helium temperatures, unveiling a captivating freeze-out phenomenon leading to the formation of excited localized states known as dipole states. Using compelling evidence from relative capacitance measurements obtained from two detectors, we elucidate the transition of impurity atoms from free charge states to these dipole states as the temperature drops from 11 to 6.5 K. Our investigation comprehensively covers the intricate formation of these dipole states in bothn-type andp-type impurities. Furthermore, we shed light on the electric field generated by these dipole states, revealing their ability to trap charges and facilitate the creation of cluster dipole states. Confirming findings from previous measurements, we establish that these excited dipole states exhibit a binding energy of less than 10 meV, offering an exceptionally low detection threshold for MeV-scale DM. Building upon this concept, we propose the development of a 1-kg Ge detector with internal charge amplification—an innovative approach poised to surpass electrical noise and enable the detection of MeV-scale DM with unprecedented sensitivity.

Physics↗

Determining HPGe Total Detection Efficiency Using γ–γ Coincidence

Abstract Both the peak and total detection efficiencies are generally needed in order to calculate sample activity from a gamma spectroscopic measurement, except in the case of isotope specific calibration. This is particularly true when the sample is in close proximity to the detector and corrections for cascade summing effects are required to avoid significant inaccuracy in the result. These corrections use the total detection efficiency to correct for summing-in and summing-out events, and the extent of the correction depends on both the geometry and the gamma cascade for the isotope in question. Experimentally determining the total efficiency is a labor intensive endeavor requiring multiple measurements with a set of single-gamma-emitting standards. Modeling the total efficiency vs. energy may be less time consuming, but is also likely to produce less confidence in the final result. Pacific Northwest National Laboratory's Radiation Detection and Nuclear Sciences group has constructed a low background 14-crystal HPGe array for sample measurement; in all measurements, samples will be in close proximity to the germanium crystals. This close geometry and the sheer number efficiency calibrations required for the system have led us to investigate methods to simplify the efficiency calibration procedure. One method we are developing uses the Y-Y coincidence plane to isolate Compton scattering event populations, allowing experimental determination of total detection efficiency values from the measurement of a single mixed isotope standard. A description of the analysis and experimental results of this method are presented.

low background HPGe High Purity Germanium detector↗

Cantilever Functionalization Using Peroxidase Extract of Low Cost for Glyphosate Detection

A cantilever nanobiosensor functionalized with vegetable source of peroxidase was developed as an innovative way for glyphosate herbicide detection over a wide concentration range (0.01 to 10 mg L{sup −1}) using atomic force microscopy (AFM) technique. The extract obtained from zucchini (Cucurbita pepo source of peroxidase), with high enzymatic activity and stability has been used as bio-recognition element to develop a nanobiosensor. The polarization-modulated reflection absorption infrared spectroscopy (PM-RAIRS) demonstrated the deposition of enzyme on cantilever surface using self-assembled monolayers (SAM) by the presence of the amide I and II bands. The detection mechanism of glyphosate was based on the changes in surface tension caused by the analyte adsorption, resulting in a conformational change in the enzyme structure. In this way, the results of nanobiosensor demonstrate the potential of the sensing device for detecting glyphosate with a detection limit of 0.028 mg L{sup −1}.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Detection of Ketones by a Novel Technology: Dipolar Proton Transfer Reaction Mass Spectrometry (DP-PTR-MS)

Proton transfer reaction mass spectrometry (PTR-MS) has played an important role in the field of real-time monitoring of trace volatile organic compounds (VOCs) due to its advantages such as low limit of detection (LOD) and fast time response. Recently, a new technology of proton extraction reaction mass spectrometry (PER-MS) with negative ions OH{sup –} as the reagent ions has also been presented, which can be applied to the detection of VOCs and even inorganic compounds. In this work, we combined the functions of PTR-MS and PER-MS in one instrument, thereby developing a novel technology called dipolar proton transfer reaction mass spectrometry (DP-PTR-MS). The selection of PTR-MS mode and PER-MS mode was achieved in DP-PTR-MS using only water vapor in the ion source and switching the polarity. In this experiment, ketones (denoted by M) were selected as analytes. The ketone (molecular weight denoted by m) was ionized as protonated ketone [M + H]{sup +} [mass-to-charge ratio (m/z) m + 1] in PTR-MS mode and deprotonated ketone [M – H]{sup –} (m/z m – 1) in PER-MS mode. By comparing the m/z value of the product ions in the two modes, the molecular weight of the ketone can be positively identified as m. Results showed that whether it is a single ketone sample or a mixed sample of eight kinds of ketones, the molecular weights can be detected with DP-PTR-MS. The newly developed DP-PTR-MS not only maintains the original advantages of PTR-MS and PER-MS in sensitive and rapid detection of ketones, but also can estimate molecular weight of ketones. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gold Nanoparticles (AuNPs) as Reactive Matrix for Detection of Trace Levels of HCN in Air by Laser Desorption/Ionization Mass Spectrometry (LDI-MS)

Under direct laser desorption/ionization mass spectrometric conditions, the irradiation of target spots made of gold nanoparticle residues generates a series of peaks at m/z 197, 394, 591… representing Au{sub n}{sup −} ions (n = 1–3). In contrast, spectra recorded from gold nanoparticles directly mixed with an alkali cyanide exhibited an additional peak at m/z 249, indicating an abundant generation of gaseous [Au(CN){sub 2}]{sup −} ions upon irradiation. The relative intensity of the m/z 249 peak surged when the amount of cyanide in the mixture was increased. Most remarkably, a peak at m/z 249 was observed even from neat AuNPs upon irradiation, if a nearby spot, which was not irradiated, happened to bear a cyanide sample. We postulated that traces of HCN emanating from the headspace of aqueous cyanide solution during the sample-plate preparation is sufficient to convert gold to AuCN, which is subsequently detected as [Au(CN){sub 2}]{sup −}. Further experiments demonstrated that the relative intensity of the m/z 249 peak diminishes exponentially as the AuNP spot becomes more distant from the putative HCN source. Eventually, the method was developed as an efficient procedure to detect HCN or alkali cyanides. Using KCN, the detection limits were determined to be below 10 pg of CN{sup −} per spot. The method also demonstrated that, upon crushing, the seeds or roots of certain fruits and vegetables such as apple, peach, radish, and cassava, but not carrot, release HCN in amounts detectable by this method. .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

On-Chip Spyhole Nanoelectrospray Ionization Mass Spectrometry for Sensitive Biomarker Detection in Small Volumes

A polyimide microfluidic chip with a microhole emitter (Ø 10–12 μm) created on top of a microchannel by scanning laser ablation has been designed for nanoelectrospray ionization (spyhole-nanoESI) to couple microfluidics with mass spectrometry. The spyhole-nanoESI showed higher sensitivity compared to standard ESI and microESI from the end of the microchannel. The limits of detection (LOD) for peptide with the spyhole-nanoESI MS reached 50 pM, which was 600 times lower than that with standard ESI. The present microchip emitter allows the analysis of small volumes of samples. As an example, a small cell lung cancer biomarker, neuron-specific enolase (NSE), was detected by monitoring the transition of its unique peptide with the spyhole-nanoESI MS/MS. NSE at 0.2 nM could be well identified with a signal to noise ratio (S/N) of 50, and thereby its LOD was estimated to be 12 pM. The potential application of the spyhole-nanoESI MS/MS in cancer diagnosis was further demonstrated with the successful detection of 2 nM NSE from 1 μL of human serum. Before the detection, the serum sample spiked with NSE was first depleted with immune spin column, then desalted by centrifugal filter device, and finally digested by trypsin, without any other complicated preparation steps. The concentration matched the real condition of clinical samples. In addition, the microchips can be disposable to avoid any cross contamination. The present technique provides a highly efficient way to couple microfluidics with MS, which brings additional values to various microfluidics and MS-based analysis. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimized Electrostatic Linear Ion Trap for Charge Detection Mass Spectrometry

In charge detection mass spectrometry (CDMS), ions are passed through a detection tube and the m/z ratio and charge are determined for each ion. The uncertainty in the charge and m/z determinations can be dramatically reduced by embedding the detection tube in an electrostatic linear ion trap (ELIT) so that ions oscillate back and forth through the detection tube. The resulting time domain signal can be analyzed by fast Fourier transforms (FFTs). The ion’s m/z is proportional to the square of the oscillation frequency, and its charge is derived from the FFT magnitude. The ion oscillation frequency is dependent on the physical dimensions of the trap as well as the ion energy. A new ELIT has been designed for CDMS using the central particle method. In the new design, the kinetic energy dependence of the ion oscillation frequency is reduced by an order of magnitude. An order of magnitude reduction in energy dependence should have led to an order of magnitude reduction in the uncertainty of the m/z determination. In practice, a factor of four improvements was achieved. This discrepancy is probably mainly due to the trajectory dependence of the ion oscillation frequency. The new ELIT design uses a duty cycle of 50%. We show that a 50% duty cycle produces the lowest uncertainty in the charge determination. This is due to the absence of even-numbered harmonics in the FFT, which in turn leads to an increase in the magnitude of the peak at the fundamental frequency. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of Neutral CO Lost During Ionic Dissociation Using Atmospheric Pressure Thermal Dissociation Mass Spectrometry (APTD-MS)

Elucidation of ion dissociation patterns is particularly important to structural analysis by mass spectrometry (MS). However, typically, only the charged fragments from an ion dissociation event are detected in tandem MS experiments; neutrals are not identified. In recent years, we have developed an atmospheric pressure thermal dissociation (APTD) technique that can be applied to dissociate ions at atmosphere pressure and thus provide one way to characterize neutral fragments. In this paper, we focus on the detection of neutral CO resulting from amino acid and peptide ion dissociation. In the first set of experiments, several protonated amino acids (e.g., + 1 ion of phenylalanine) were found to undergo loss of a neutral (s) of total mass 46 Da, a process leading to iminium ion formation. We successfully detected the neutral species CO by using a CO sensor, UV-Vis and MS analysis following selective CO trapping with a rhodium complex. The capture of CO from dissociation of protonated amino acids supports the assignment of the loss of 46 Da to neutral losses of CO and H{sub 2}O, rather than loss of formaldehyde or dihydroxycarbene, other possible fragmentation pathways that have been subject of debate for a long time. In a second experiment, we used the APTD method in combination with the CO detection technique, to demonstrate the formation of CO in the conversion of b ions to a ions during peptide ion dissociations. These results showed the potential of APTD in the elucidation of ion dissociation mechanisms, using simple home-built apparatus. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Simultaneous Detection and Removal of Formaldehyde at Room Temperature: Janus Au@ZnO@ZIF-8 Nanoparticles

The detection and removal of volatile organic compounds (VOCs) are of great importance to reduce the risk of indoor air quality concerns. Our study reports the rational synthesis of a dual-functional Janus nanostructure and its feasibility for simultaneous detection and removal of VOCs. The Janus nanostructure was synthesized via an anisotropic growth method, composed of plasmonic nanoparticles, semiconductors, and metal organic frameworks (e.g., Au@ZnO@ZIF-8). It exhibits excellent selective detection to formaldehyde (HCHO, as a representative VOC) at room temperature over a wide range of concentrations (from0.25 to 100 ppm), even in the presence of water and toluene molecules as interferences. Additionally, HCHOwas also found to be partially oxidized into non-toxic formic acid simultaneously with detection. The mechanism underlying this technology was unraveled by both experimental measurements and theoretical calculations: ZnO maintains the conductivity, while ZIF-8 improves the selective gas adsorption; the plasmonic effect of Au nanorods enhances the visible-light-driven photocatalysis of ZnO at room temperature.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Single-atom materials boosting wearable orthogonal uric acid detection

Abstract Uric acid (UA) is a vital biomarker for the diagnosis and management of various health conditions, including cardiovascular diseases, gout, kidney disorders, metabolic syndrome, and wound healing. Despite significant advances in wearable sensor technology, challenges persist in developing wearable sensors that are capable of maintaining high sensitivity, selectivity, and stability. In this study, we present an epidermal sensing platform enhanced with single-atom materials (SAMs) designed for flexible and orthogonal electrochemical detection of UA. We designed and synthesized an SAM with Fe-N 5 active sites to boost the electrochemical sensing signals, integrating it with laser-engraved graphene (LEG) to fabricate a wearable SAM-based UA patch sensor. This design provides superior UA detection performance compared to sensors based on conventional nanomaterials. In addition, we enhanced the detection accuracy and range by using an orthogonal approach that combines direct oxidation through differential pulse voltammetry (DPV) along with parallel biocatalytic amperometric detection. The resulting SAM-based UA orthogonal sensor patch demonstrated exceptional performance in wearable applications through tests measuring sweat UA levels in subjects before and after consuming a purine-rich diet. Graphical Abstract

Ding, Shichao↗

Automated detection of part quality during two-photon lithography via deep learning

Two-photon lithography (TPL) is an additive manufacturing technique for fabricating three-dimensional objects with nanoscale features. A main challenge of TPL is the routine and labor-intensive task of finding suitable light dosage parameters, i.e. writing speed and laser intensity that induce photo-polymerization within a wide variety of candidate photo-curing polymers. Another challenge is the monitoring required during fabrication. In this work, we apply machine learning (ML) models to accelerate the process of identifying optimal light dosage parameters and automate the detection of part quality. We curate TPL videos of different parts fabricated under a range of light dosage parameters using different resins and train spatial-temporal ML models on this data. Our results show that ML models can detect TPL part quality with a 95.1% accuracy in milliseconds. We also evaluate classification failures and identify two operating modes: parameter optimization and part quality detection. Last but not least, we publicly release this labelled dataset so that it may serve as a useful benchmark to the community. Our approach to process optimization and part quality detection addresses important aspects of TPL industrialization, is applicable beyond TPL and should benefit other additive manufacturing techniques with similar barriers to operating at industrial scale.

36 MATERIALS SCIENCE↗

Effects of digital fringe projection operational parameters on detecting powder bed defects in additive manufacturing

Additive manufacturing is a technology transforming traditional production timelines. Specifically, metal additive manufacturing (MAM) has been increasingly adopted by a variety of industries, not only to prototype, but also to fulfill full production scale applications with much lower lead times. Like any maturing manufacturing technology, developments in verifying and validating processes are necessary to support continuous growth. Due to the complex nature of MAM, part quality and repeatability remain integral challenges that inhibit further adoption of MAM for critical component production. In this study, we present data taken from a developing in-process monitoring system designed to measure and detect powder bed defects (PBDs) in powder bed fusion MAM systems using surface height maps created with structured light illumination. We showcase the feasibility of the monitoring technique for in-process implementation by detecting streak PBDs with varying severities (height, width) created in a lab environment. We present results of powder bed measurements for varying experimental parameters of the structured light system such as illumination angle, illumination pattern, and number of illuminations. We also present an expression used to determine experimental height noise based on input parameters for PBD detection based on the instrument transfer function of the structured light monitoring system for arbitrary pixel intensity noise contributions. In conclusion, with the results of PBD detection across multiple experimental measurement parameters, we provide a best practices approach to in-process implementation of the monitoring system in powder bed fusion manufacturing.

36 MATERIALS SCIENCE↗

Gear-box fault detection using time-frequency based methods

Gear-box fault monitoring and detection is important for optimization of power generation and availability of wind turbines. The current industrial approach is to use condition monitoring systems, which runs in parallel with the wind turbine control system, using expensive additional sensors. An alternative would be to use the existing measurements which are normally available for the wind turbine control system. The usage of these sensors instead would cut down the cost of the wind turbine by not using additional sensors. One of these available measurements is the generator speed, in which changes in the gear-box resonance frequency can be detected. Two different time-frequency based approaches are presented in this paper. One is a filter based approach and the other is based on a Karhunen-Loeve basis. Both of them detects the gear-box fault with an acceptable detection delay.

Odgaard, Peter Fogh↗