Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Efficiency and Demand Flexibility in Large Office Buildings: The Potential for Cost Savings and CO 2 Reductions from Lighting and Cooling Measures

This report presents the estimated impact of lighting and cooling efficiency and demand flexibility measures in large office buildings in each state in the contiguous United States. It provides modeled results for three different metrics: bill savings, regional grid operational costs savings, and carbon dioxide (CO 2 ) emissions reductions. Lighting efficiency and demand flexibility are estimated to reduce load by up to 80 MWh/yr in a single large office building. These load reductions result in customer bill savings of up to $8,800/yr per building, with the highest savings in southern and midwestern states. Grid operating cost savings are estimated at up to $3,240/yr/building, with greatest benefit in southern and northeastern states. CO 2 emissions reduction potential is highest in the Dakotas, Nebraska, across the Midwest, in West Virginia, and in Mississippi (<48,200 kg/yr/building). Comparatively, cooling measures are found to have less load reduction potential (<28.5 MWh/yr/building), with the greatest potential in southern states including Texas, which ranks top of the list across several of the metrics studied. In numerous states, shifting cooling load to off-peak hours is found to increase costs and CO 2 emissions because precooling results in increased load during high-cost or high-CO 2 emissions periods. In general, focusing on cooling efficiency and load shedding has the potential for more savings. In all cases, the specific rate structure is a significant determinant in actual bill savings, which are up to $4,000/yr/building. To realize the full potential for bill savings through an energy measure, building operators must identify how the measure will change the building load pattern and the interaction of this load change with the applicable rate tariff. To realize CO 2 emissions reductions, industry and state coordination is needed to verify which fuel source is on the margin and then to create incentives for end users to reduce load during high-CO 2 emissions hours. Regular updates to data sets and analyses are critical. Regulators and policymakers are well positioned to facilitate the necessary coordination between the electric industry and building energy managers to develop appropriate price signals and incentives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pressure Spike in The LBNF Absorber Core s Gun Drilled Cooling Channel from an Accident Beam Pulse

he LBNF absorber consists of thirteen 6061-T6 aluminum core blocks. The core blocks are water cooled with de-ionized (DI) water which becomes radioactive during beam operations. The cooling water flows through gun-drilled channels in the core blocks. The cooling water is supplied by the LBNF absorber radioactive water (RAW) cooling system which is designed as per ASME B31.3 normal fluid service. An uninhibited beam accident pulse striking the water channels was identified as a credible accident scenario. In this study, it is assumed that the beam pulse hits the absorber directly without interacting with any of the other upstream beamline components. The beam parameters used for the LBNF beam are 120 GeV, 2.4 MW with a 1.2 s cycle time. The accident pulse lasts for 10 µs. The maximum energy is deposited in the 3rd aluminum core block. For the sake of simplicity, it is assumed that the accident pulse strikes the 1 in. ID water channel directly. The analysis here simulates the pressure rise in the water during and after the beam pulse and its effects on the aluminum piping components that deliver water to the core blocks. The weld strengths as determined by the Load and Resistance Factor Design (LRDF) and the Allowable Strength Design (ASD) are compared to the forces generated in the weld owing to the pressure spike. A transient structural analysis was used to determine the equivalent membrane, peak, and bending stresses and they were compared to allowable limits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New Advances in Optical Stochastic Cooling

Recently, Optical Stochastic Cooling (OSC) became the first demonstrated method for ultra-high-bandwidth stochastic cooling. The initial experiments at Fermilab’s IOTA ring explored the essential physics of the method and demonstrated cooling, heating and manipulation of beams and single particles. Having been validated in practice, with continued development, OSC carries the potential for dramatic advances in the state-of-the-art performance and flexibility for beam cooling and control. The ongoing program at Fermilab is now focused on the development of an OSC system that includes high-gain optical amplification, which promises a two-order-of-magnitude increase in the strength of the OSC force. In this talk, we briefly review the results of the initial experimental campaign, describe the status of the conceptual and hardware designs for the amplified OSC system, report initial experimental results of our high-gain amplifier development, and explore near-term operational plans and use cases.

43 PARTICLE ACCELERATORS↗

U-gas +Cool GTL™ - A New Integrated Process for Direct Biomass Conversion to Liquid Fuels

The U-Gas gasification technology, marketed by Sungas, is a proven fluid bed gasification technology for biomass conversion. U-Gas has been tested on a wide variety of biomass feeds including wood and waste streams. The U-Gas Technology has successfully converted wood for more than 20 years in a gasification plant in Skive Denmark at the 150t/d size. GTI has also recently developed the Cool GTL process for converting biogas to high quality gasoline, jet, and diesel fuels. The technoeconomics and LCA for the combination of the two technologies results an integrated optimized process, which will be discussed. The Cool GTL process is still in development and the development should be complete by 2023. Cool GTL converts high CO2 content feeds to synthesis gas with a 2-2.4/1 H2/CO ratio suitable for fuels synthesis. The process is based on a novel, highly stabile CO2/steam reforming catalyst. The 2.0-2.4/1 H2/CO synthesis gas ratio is always achieved, independently of feed CO2 content, by adjusting the amount of water added according to the amount of CO2 in the feed. The reformer catalyst has been tested for 500 hours and shows no measurable deactivation. The product from the reformer then goes directly to a low temperature slurry bed Fischer Tropsch reactor with an integrated finishing hydroisomerization reactor which makes hydrocarbon liquids from the synthesis gas. With this configuration no wax is produced. The technoeconomics and carbon intensity for the integration of UGas and the Cool GTL processes will be compared to other biomass conversion approaches. The use of electrolysis to boost H2 in the feed and increase liquid production will also be analyzed as a potential process improvement with sensitivities to the cost of electricity and the use of renewable electricity.

09 BIOMASS FUELS↗

The Optical Stochastic Cooling Program at Fermilab

Recently, Optical Stochastic Cooling (OSC) became the first demonstrated method for ultra-high-bandwidth stochastic cooling. The initial experiments at Fermilab’s IOTA ring explored the essential physics of the method and demonstrated cooling, heating and manipulation of beams and single particles. Having been validated in practice, with continued development, OSC carries the potential for dramatic advances in the state-of-the-art performance and flexibility for beam cooling and control. The ongoing program at Fermilab is now focused on the development of an OSC system that includes high-gain optical amplification, which promises a two-order-of-magnitude increase in the strength of the OSC force. Here we review the progress and plans for the amplified OSC program. This includes detailed lattice designs and tracking simulations for the various experimental configurations, designs and status for the various hardware systems, and near-term operational plans and use cases.

Jarvis, J. [Fermilab]↗

Perspective of a Dual Energy Electron Storage Ring Cooler for a Hadron Beam Cooling

A dual energy electron storage ring cooler was proposed and explored to maintain a good hadron beam quality against intra-beam scattering and all heating sources in a collider. The unique configuration of this concept is that electron beam in the low energy section extracts heat away from the hadron beam through Coulomb interaction while electron beam in the high energy section releases heat through its intrinsic synchrotron radiation damping. The early design employs a magnetized electron beam for achieving a high cooling efficiency. Recently, a non-magnetized cooling electron beam was explored in this dual energy cooler. It could meet the same cooling requirements while lowering the risks. This paper presents study results on design and optimization of a dual energy storage ring cooler and describes the trade-offs between using magnetized and non-magnetized cooling for this approach.

Lin, Fanglei↗

Steady-State Microbunching using Optical Stochastic Cooling

Optical Stochastic Cooling (OSC) is a state-of-the-art beam cooling technology first demonstrated in 2021 at the IOTA storage ring at Fermilab's FAST facility. A second phase of the research program is planned to run in 2026 and will incorporate an optical amplifier to enable significantly increased cooling rates and greater operational flexibility. In addition to beam cooling, an OSC system can be configured to enable advanced control over the phase space of the beam. An example operational mode could enable crystallization, where the particles in a bunch are locked into a self-reinforcing, regular microstructure at the OSC fundamental wavelength; we refer to this as Optical Stochastic Crystallization (OSX). OSX represents a new path toward Steady-State Microbunching (SSMB), which may enable light sources combining the high brightness of a free-electron laser with the high repetition rate of a storage ring. Such a source has applications from the terahertz to the extreme ultraviolet (EUV), including high-power EUV generation for semiconductor lithography. This contribution will discuss the integration of OSX development as part of the OSC program at IOTA. The design of an accelerator lattice to enable the mechanism and associated high fidelity simulations demonstrating the beam dynamics will be shown, and a path to realizing an experimental demonstration will be discussed.

Wallbank, Michael James [Fermilab]↗

Dual Purpose – Heating & Cooling – Thermal Battery for Flexible and Energy-Efficient Heat Pump Systems

The integration of heat pumps with thermal energy storage (HP-TES) systems is gaining attention as a viable solution for managing peak building demand driven by immense cooling and heating loads. With growing reliance on renewable energy sources, thermal energy storage offers an excellent opportunity to mitigate mismatches in thermal load between energy supply and demand. The use of phase-change material (PCM) TES is especially promising, as PCMs offer significant latent energy storage capacity with smaller temperature glides in smaller volumes compared to other TES technologies. However, challenges arise because current HP-TES architectures can load-shift only cooling or heating, not both, requiring two systems and thus doubling cost, weight, and footprint. Furthermore, current research efforts lack specific tools and techniques to advance integrated systems from concept design to end-user application, focusing on only discharge performance. To address these challenges, this research proposes a dual-mode (heating and cooling) integrated HP-TES system that uses room-temperature PCM-TES as a high-temperature heat source in heating mode and a low-temperature heat sink in cooling mode, thereby reducing temperature lifts and compressor power. Design criteria for PCM-TES heat exchangers were developed, balancing thermal-hydraulic performance with practical constraints such as available building space and weight requirements along with PCM selection considerations such as shipping conditions, moisture exposure, and number of available cycles. A detailed transient model for HP-TES systems was developed to enable rapid annual performance assessments in any US climate zone.

42 ENGINEERING↗

Optimizations of a Rectilinear Cooling Channel for a Future Muon Collider

Muon colliders require significant beam cooling to achieve the luminosity needed for high-energy physics experiments. Ionization cooling has emerged as a promising solution. This study optimizes a rectilinear muon cooling channel using a multi-objective optimization framework that integrates beam dynamics simulations. We present novel optimizations of final 6D emittance versus total system length as well as those confirming the theoretical trade-offs between transverse and longitudinal emittance. Our results optimizing all stages of the system simultaneously surpass performance benchmarks reported in the literature, demonstrating possible ways to improve the efficiency of such a cooling system.

Zhang, Aubrey [U. Chicago (main)]↗

Optimizations of a Rectilinear Cooling Channel for a Future Muon Collider

Muon colliders require significant beam cooling to achieve the luminosity needed for high-energy physics experiments. Ionization cooling has emerged as a promising solution. This study optimizes a rectilinear muon cooling channel using a multi-objective optimization framework that integrates beam dynamics simulations. We present novel optimizations of final 6D emittance versus total system length as well as those confirming the theoretical trade-offs between transverse and longitudinal emittance. Our results optimizing all stages of the system simultaneously surpass performance benchmarks reported in the literature, demonstrating possible ways to improve the efficiency of such a cooling system.

Zhang, Aubrey [U. Chicago (main)]↗

Mechanics and Cooling of the CMS Phase-II Tracker Barrel

The CMS upgrade for the High-Luminosity LHC (HL-LHC) era will allow for an incredibly high rate of data collection, to be used in the next generation of precision measurements and searches for beyond the standard model physics. A key element of this upgrade is the full replacement of the silicon strip tracker to enable level-1 triggering on track level primitives, produced by pixel-strip (PS) and strip-strip (2S) modules, tiled together to form the new detector. Mechanically supporting and cooling these modules is not trivial, as material budget in the tracker volume is highly constrained, and as the modules accrue radiation damage they risk becoming entirely non-functional if the silicon sensors are not sufficiently cooled. To address this, each region of the tracker has a bespoke solution for housing and cooling their modules, mostly depending on carbon-fiber and carbon-foam structures, with dual phase CO2 cooling. For the most central part of the tracker, the Flat Barrel with PS modules (Flat TBPS) covers the pseudorapidity range out to $|\eta|=0.4$, and the mechanical structures are manufactured, assembled, and tested entirely by Fermilab and UC Davis. This presentation will describe the intense design and testing requirements for these components, and how they will ensure strong performance of the tracker through the HL-LHC era.

Cosby, Christopher [Fermilab]↗

Quantitative Analysis of the Principal-Agent Problem in Commercial Buildings in the U.S.: Focus on Central Space Heating and Cooling

We investigate the existence of the principal-agent (PA) problem in non-government, non-mall commercial buildings in the U.S. in 2003. The analysis concentrates on space heating and cooling energy consumed by centrally installed equipment in order to verify whether a market failure caused by the PA problem might have prevented the installation of energy-efficient devices in non-owner-occupied buildings (efficiency problem) and/or the efficient operation of space-conditioning equipment in these buildings (usage problem). Commercial Buildings Energy Consumption Survey (CBECS) 2003 data for single-owner, single-tenant and multi-tenant occupied buildings were used for conducting this evaluation. These are the building subsets with the appropriate conditions for assessing both the efficiency and the usage problems. Together, these three building types represent 51.9percent of the total floor space of all buildings with space heating and 59.4percent of the total end-use energy consumption of such buildings; similarly, for space cooling, they represent 52.7percent of floor space and 51.6percent of energy consumption. Our statistical analysis shows that there is a usage PA problem. In space heating it applies only to buildings with a small floor area (<_50,000 sq. ft.). We estimate that in 2003 it accounts for additional site energy consumption of 12.3 (+ 10.5 ) TBtu (primary energy consumption of 14.6 [+- 12.4] TBtu), corresponding to 24.0percent (+- 20.5percent) of space heating and 10.2percent (+- 8.7percent) of total site energy consumed in those buildings. In space cooling, however, the analysis shows that the PA market failure affects the complete set of studied buildings. We estimate that it accounts for a higher site energy consumption of 8.3 (+-4.0) TBtu (primary energy consumption of 25.5 [+- 12.2]TBtu), which corresponds to 26.5percent (+- 12.7percent) of space cooling and 2.7percent (+- 1.3percent) of total site energy consumed in those buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A fundamentally new approach to air-cooled heat exchangers.

We describe breakthrough results obtained in a feasibility study of a fundamentally new architecture for air-cooled heat exchangers. A longstanding but largely unrealized opportunity in energy efficiency concerns the performance of air-cooled heat exchangers used in air conditioners, heat pumps, and refrigeration equipment. In the case of residential air conditioners, for example, the typical performance of the air cooled heat exchangers used for condensers and evaporators is at best marginal from the standpoint the of achieving maximum the possible coefficient of performance (COP). If by some means it were possible to reduce the thermal resistance of these heat exchangers to a negligible level, a typical energy savings of order 30% could be immediately realized. It has long been known that a several-fold increase in heat exchanger size, in conjunction with the use of much higher volumetric flow rates, provides a straight-forward path to this goal but is not practical from the standpoint of real world applications. The tension in the market place between the need for energy efficiency and logistical considerations such as equipment size, cost and operating noise has resulted in a compromise that is far from ideal. This is the reason that a typical residential air conditioner exhibits significant sensitivity to reductions in fan speed and/or fouling of the heat exchanger surface. The prevailing wisdom is that little can be done to improve this situation; the 'fan-plus-finned-heat-sink' heat exchanger architecture used throughout the energy sector represents an extremely mature technology for which there is little opportunity for further optimization. But the fact remains that conventional fan-plus-finned-heat-sink technology simply doesn't work that well. Their primary physical limitation to performance (i.e. low thermal resistance) is the boundary layer of motionless air that adheres to and envelops all surfaces of the heat exchanger. Within this boundary layer region, diffusive transport is the dominant mechanism for heat transfer. The resulting thermal bottleneck largely determines the thermal resistance of the heat exchanger. No one has yet devised a practical solution to the boundary layer problem. Another longstanding problem is inevitable fouling of the heat exchanger surface over time by particulate matter and other airborne contaminants. This problem is especially important in residential air conditioner systems where often little or no preventative maintenance is practiced. The heat sink fouling problem also remains unsolved. The third major problem (alluded to earlier) concerns inadequate airflow to heat exchanger resulting from restrictions on fan noise. The air-cooled heat exchanger described here solves all of the above three problems simultaneously. The 'Air Bearing Heat Exchanger' provides a several-fold reduction in boundary layer thickness, intrinsic immunity to heat sink fouling, and drastic reductions in noise. It is also very practical from the standpoint of cost, complexity, ruggedness, etc. Successful development of this technology is also expected to have far reaching impact in the IT sector from the standpointpoint of solving the 'Thermal Brick Wall' problem (which currently limits CPU clocks speeds to {approx}3 GHz), and increasing concern about the the electrical power consumption of our nation's information technology infrastructure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical Investigation of Wall-Cooling Effect on Aero-Optical Distortions for Hypersonic Boundary Layer

Compressible wall-modeled large-eddy simulations of Mach 8 turbulent boundary-layer flows over a flat plate were carried out for the conditions of the hypersonic wind tunnel at Sandia National Laboratories. The simulations provide new insight into the effect of wall cooling on the aero-optical path distortions for hypersonic turbulent boundary-layer flows. Four different wall-to-recovery temperature ratios, 0.3, 0.48, 0.71, and 0.89, are considered. Despite the much lower grid resolution, the mean velocity, temperature, and resolved Reynolds stress profiles from the simulation for a temperature ratio of 0.48 are in good agreement with those from a reference direct numerical simulation. The normalized root-mean-square optical path difference obtained from the present simulations is compared with that from reference direct numerical simulations, Sandia experiments, as well as predictions obtained with a semi-analytical model by Notre Dame University. Here the present analysis focuses on the effect of wall cooling on the wall-normal density correlations, on key underlying assumptions of the aforementioned model such as the strong Reynolds analogy, and on the elevation angle effect on the optical path difference. Wall cooling is found to increase the velocity fluctuations and decrease the density fluctuations, resulting in an overall reduction of the normalized optical path distortion. Compared to the simulations, the basic strong Reynolds analogy overpredicts the temperature fluctuations for cooled walls. Also different from the strong Reynolds analogy, the velocity and temperature fluctuations are not perfectly anticorrelated. Finally, as the wall temperature is raised, the density correlation length, away from the wall but inside the boundary layer, increases significantly for beam paths tilted in the downstream direction.

42 ENGINEERING↗

On the minimum number of radiation field parameters to specify gas cooling and heating functions

Fast and accurate approximations of gas cooling and heating functions are needed for hydrodynamic galaxy simulations. We use machine learning to analyze atomic gas cooling and heating functions in the presence of a generalized incident local radiation field computed by Cloudy. We characterize the radiation field through binned radiation field intensities instead of the photoionization rates used in our previous work. We find a set of 6 energy bins whose intensities exhibit relatively low correlation. We use these bins as features to train machine learning models to predict Cloudy cooling and heating functions at fixed metallicity. We compare the relative SHapley Additive exPlanation (SHAP) value importance of the features. From the SHAP analysis, we identify a feature subset of 3 energy bins (0.5-1, 1-4, and 13-16Ry) with the largest importance and train additional models on this subset. We compare the mean squared errors and distribution of errors on both the entire training data table and a randomly selected 20% test set withheld from model training. The machine learning models trained with 3 and 6 bins, as well as 3 and 4 photoionization rates, have comparable accuracy everywhere, with errors ≳10 times smaller than for the interpolation table of Gnedin and Hollon (2012). We conclude that 3 energy bins (or 3 analogous photoionization rates: molecular hydrogen photodissociation, neutral hydrogen HI, and fully ionized carbon CVI) are sufficient to characterize the dependence of the gas cooling and heating functions on our assumed incident radiation field model.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of Cooling Rate on Nano-Eutectic Formation in Laser Surface Remelted and Rare Earth Modified Hypereutectic Al-20Si Alloys

Laser Surface Remelting (LSR) was applied to arc-melted Al-20Si-0.2Sr, Al-20Si-0.2Ce, and Al-20Si hypereutectic alloys to refine microstructures. Experiments revealed that microstructures in the melt pool varied from fully eutectic to a mixture of Al dendrites and inter-dendritic eutectic. We calculated cooling rates using the Eagar-Tsai model and correlated cooling rates with characteristic microstructures, revealing that a cooling rate on the order of 104 K/s could lead to maximized fully eutectic microstructure morphology. Due to rapid solidification, the Si composition in the LSR eutectic was measured at 18.2 wt.%, higher than the equilibrium eutectic composition of 12.6 wt.%Si. Compared to Al-20Si, Ce addition had no significant effect on the volume fraction of the fully eutectic structure but refined Si fibers to approximately 30 nm in diameter. Sr addition did not further refine the diameter of eutectic Si fibers compared to Al-20Si but increased the volume fraction of the fully eutectic microstructure morphology. The refinement ratio (φ) of the Si fiber diameter from the bottom of the melt pool to the surface for the three alloys was similar, at around 28%. The established correlation between the cooling rate and the size and morphology of the microstructure within the melt pool will enable tailoring of the microstructure in laser-processed as well as deposited alloys for high strength and plasticity.

36 MATERIALS SCIENCE↗

Urca cooling pairs in the neutron star ocean and their effect on superbursts

An accretion outburst onto a neutron star deposits hydrogen-rich and/or helium-rich material into the neutron star’s envelope. Thermonuclear burning of accreted material robustly produces Urca pairs—pairs of nuclei that undergo cycles of e{sup −}-capture and β{sup −}-decay. The strong T {sup 5} dependence of the Urca cooling neutrino luminosity means that Urca pairs in the neutron star interior potentially remove heat from accretion-driven nuclear reactions. In this study, we identify Urca pairs in the neutron star’s ocean—a plasma of ions and electrons overlaying the neutron star crust—and demonstrate that Urca cooling occurs at all depths in the ocean. We find that Urca pairs in the ocean and crust lower the ocean’s steady-state temperature during an accretion outburst and that unstable carbon ignition, which is thought to trigger superbursts, occurs deeper than it would otherwise. Cooling superburst light curves, however, are only marginally impacted by cooling from Urca pairs because the superburst peak radiative luminosity L{sub peak} is always much greater than the Urca pair neutrino luminosity L{sub ν} in the hot post-superburst ocean.

79 ASTRONOMY AND ASTROPHYSICS↗

Embedded Spiral Patterns in the Cool Core of the Massive Cluster of Galaxies Abell 1835

We present the properties of an intracluster medium (ICM) in the cool core of the massive cluster of galaxies, Abell 1835, obtained with the data from the Chandra X-ray Observatory. We find distinctive spiral patterns with a radius of 70 kpc (or 18″) as a whole in the residual image of the X-ray surface brightness after the two-dimensional ellipse model of surface brightness is subtracted. The size is smaller by a factor of 2–4 than that of other clusters that are known to have a similar pattern. The spiral patterns consist of two arms. One of them appears as positive, and the other appears as negative excesses in the residual image. Their X-ray spectra show that the ICM temperatures in the positive- and negative-excess regions are 5.09{sub −0.13}{sup +0.12} keV and 6.52{sub −0.15}{sup +0.18} keV, respectively. In contrast, no significant difference is found in the abundance or pressure, the latter of which suggests that the ICM in the two regions of the spiral patterns is near or is in pressure equilibrium. The spatially resolved X-ray spectroscopy of the central region (r<40{sup ′′}), divided into 92 sub-regions indicates that Abell 1835 is a typical cool core cluster. We also find that the spiral patterns extend from the cool core out to the hotter surrounding ICM. The residual image reveals some lumpy substructures in the cool core. The line of sight component of the disturbance velocity that is responsible for the substructures is estimated to be lower than 600 km s{sup −1}. Abell 1835 may now be experiencing an off-axis minor merger.

79 ASTRONOMY AND ASTROPHYSICS↗