Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Semi-Dynamic Leach Testing of Densified Silicon-based Iodine Waste Forms

Iodine waste forms (IWF) require a conceptual corrosion release model (CCRM) to provide iodine (I) release rates for performance modeling nuclear waste disposal repositories. To develop a CCRM, an understanding of the corrosion mechanisms of the IWF are required along with data from consistent test methods to parameterize the model. The present study has advanced both areas by providing and assessing the corrosion resistance of IWF types based on their processing history in minor variations of semi-dynamic leach tests. The test included a series of semi-dynamic leach tests using monolithic IWFs in deionized water (leachant). Several experiments were conducted under alternate test conditions with changes to temperature, leachant replacement, leachant pH, leachant volume, masking, and surface finish to elucidate if varying these conditions impacted IWF corrosion behavior. Tests were conducted on two classes of IWFs: (1) I-bearing silver-mordenite (AgZ) materials processed by hot isostatic pressing (HIP) at different temperatures, pressures, sizes, and times; and (2) I-bearing silver-functionalized silica aerogels (SFA) processed by either HIP or spark plasma sintering (SPS). The corrosion susceptibility of AgZ samples was influenced by HIP temperature and pressure. The SPS SFAs retained I far better than HIP SFAs. Additional findings in this study include: (1) The iodine dissolution rate decreased with decreasing temperature, (2) a common ion effect may occur and slow dissolution of the host phase if the leachant is not regularly replaced, (3) pH controls the dissolution rate, and (4) the iodine dissolution rate slows with extended test time (up to 224 days). Based on this work, these parameters should thus be represented when developing a CCRM.

corrosion↗

New Tank Mapping Method Improves Waste Removal Process

Savannah River Mission Completion is the Liquid Waste (LW) contractor at the Savannah River Site (SRS). The LW mission is tasked with treating and disposing of legacy nuclear waste. There are multiple facilities involved in this work, including the Concentration, Storage, and Transfer Facilities (CSTF), the Defense Waste Processing Facility (DWPF), the Salt Waste Processing Facility (SWPF), and the Saltstone Production Facility (SPF). The CSTF includes 43 underground waste tanks used to store and support processing of radioactive liquid waste. Waste removal activities, such as salt dissolution campaigns and sludge agitation, are conducted within the CSTF waste tanks to convert the waste into a form that allows for downstream processing at other LW facilities. While performing these waste removal campaigns, camera inspections are performed to assess the quantity and distribution of the remaining waste within the waste tank (i.e. saltcake or sludge). Understanding the quantity and distribution of the salt/sludge within the waste tanks allows for improved waste removal strategies (e.g. mixing pump operation) and refined safety controls. Typically, several camera inspections are performed during a waste removal transfer to verify the elevation of the visible salt/sludge mounds against the known elevation of the liquid surface. The camera inspection footage must then be interpreted by a trained engineer who will develop a 2-D map that depicts the waste distribution at various elevations within the waste tank. This tank mapping is then used in conjunction with conservative assumptions to evaluate the volume of saltcake or sludge that is present within the waste tank.

Mini, Melany↗

Proton Therapy for Reirradiation of Progressive or Recurrent Chordoma

Purpose: To report the results in patients reirradiated with proton therapy for recurrent or progressive chordoma, with or without salvage surgery. Methods and Materials: A retrospective review of 16 consecutive patients treated from 2005 to 2012 was performed. All patients had received at least 1 prior course of radiation therapy to the same area, and all but 1 patient had at least 1 surgical resection for disease before receiving reirradiation. At the time of recurrence or progression, half of the patients underwent additional salvage surgery before receiving reirradiation. The median prior dose of radiation was 75.2 Gy (range, 40-79.2 Gy). Six patients had received prior proton therapy, and the remainder had received photon radiation. The median gross tumor volume at the time of reirradiation was 71 cm{sup 3} (range, 0-701 cm{sup 3}). Reirradiation occurred at a median interval of 37 months after prior radiation (range, 12-129 months), and the median dose of reirradiation was 75.6 Gy (relative biological effectiveness [RBE]) (range. 71.2-79.2 Gy [RBE]), given in standard daily fractionation (n=14) or hyperfractionation (n=2). Results: The median follow-up time was 23 months (range, 6-63 months); it was 26 months in patients alive at the last follow-up visit (range, 12-63 months). The 2-year estimate for local control was 85%, overall survival 80%, chordoma-specific survival 88%, and development of distant metastases 20%. Four patients have had local progression: 3 in-field and 1 marginal. Late toxicity included grade 3 bitemporal lobe radionecrosis in 1 patient that improved with hyperbaric oxygen, a grade 4 cerebrospinal fluid leak with meningitis in 1 patient, and a grade 4 ischemic brainstem stroke (out of radiation field) in 1 patient, with subsequent neurologic recovery. Conclusions: Full-dose proton reirradiation provided encouraging initial disease control and overall survival for patients with recurrent or progressive chordoma, although additional toxicities may develop with longer follow-up times.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Prospective Quasi-Randomized Comparison of Intraoperatively Built Custom-Linked Seeds Versus Loose Seeds for Prostate Brachytherapy

Purpose: To compare dosimetric parameters, seed migration rates, operation times, and acute toxicities of intraoperatively built custom-linked (IBCL) seeds with those of loose seeds for prostate brachytherapy. Methods and Materials: Participants were 140 patients with low or intermediate prostate cancer prospectively allocated to an IBCL seed group (n=74) or a loose seed group (n=66), using quasirandomization (allocated by week of the month). All patients underwent prostate brachytherapy using an interactive plan technique. Computed tomography and plain radiography were performed the next day and 1 month after brachytherapy. The primary endpoint was detection of a 5% difference in dose to 90% of prostate volume on postimplant computed tomography 1 month after treatment. Seed migration was defined as a seed position >1 cm from the cluster of other seeds on radiography. A seed dropped into the seminal vesicle was also defined as a migrated seed. Results: Dosimetric parameters including the primary endpoint did not differ significantly between groups, but seed migration rate was significantly lower in the IBCL seed group (0%) than in the loose seed group (55%; P<.001). Mean operation time was slightly but significantly longer in the IBCL seed group (57 min) than in the loose seed group (50 min; P<.001). No significant differences in acute toxicities were seen between groups (median follow-up, 9 months). Conclusions: This prospective quasirandomized control trial showed no dosimetric differences between IBCL seed and loose seed groups. However, a strong trend toward decreased postimplant seed migration was shown in the IBCL seed group.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Regional Lymph Node Uptake of [{sup 18}F]Fluorodeoxyglucose After Definitive Chemoradiation Therapy Predicts Local-Regional Failure of Locally Advanced Non-Small Cell Lung Cancer: Results of ACRIN 6668/RTOG 0235

Purpose: The American College of Radiology Imaging Network (ACRIN) 6668/Radiation Therapy Oncology Group (RTOG) 0235 study demonstrated that standardized uptake values (SUV) on post-treatment [{sup 18}F]fluorodeoxyglucose-positron emission tomography (FDG-PET) correlated with survival in locally advanced non-small cell lung cancer (NSCLC). This secondary analysis determined whether SUV of regional lymph nodes (RLNs) on post-treatment FDG-PET correlated with patient outcomes. Methods and Materials: Included for analysis were patients treated with concurrent chemoradiation therapy, using radiation doses ≥60 Gy, with identifiable FDG-avid RLNs (distinct from primary tumor) on pretreatment FDG-PET, and post-treatment FDG-PET data. ACRIN core laboratory SUV measurements were used. Event time was calculated from the date of post-treatment FDG-PET. Local-regional failure was defined as failure within the treated RT volume and reported by the treating institution. Statistical analyses included Wilcoxon signed rank test, Kaplan-Meier curves (log rank test), and Cox proportional hazards regression modeling. Results: Of 234 trial-eligible patients, 139 (59%) had uptake in both primary tumor and RLNs on pretreatment FDG-PET and had SUV data from post-treatment FDG-PET. Maximum SUV was greater for primary tumor than for RLNs before treatment (P<.001) but not different post-treatment (P=.320). Post-treatment SUV of RLNs was not associated with overall survival. However, elevated post-treatment SUV of RLNs, both the absolute value and the percentage of residual activity compared to the pretreatment SUV were associated with inferior local-regional control (P<.001). Conclusions: High residual metabolic activity in RLNs on post-treatment FDG-PET is associated with worse local-regional control. Based on these data, future trials evaluating a radiation therapy boost should consider inclusion of both primary tumor and FDG-avid RLNs in the boost volume to maximize local-regional control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Overview of the Long-Term Stewardship of the Remediated Uranium Mining and Milling Sites in Europe - 20079

Uranium mining in Europe began in the ' 40's for civil and military applications. The great majority of the uranium mines have now been closed and are going through the stages of decommissioning and/or rehabilitation. Today, the main uranium producers are outside the EU; only a few mines are still in operation inside the EU. In 2006, the situation of the uranium mines and mill tailings in Europe, identifying the tailings liabilities, their status, the plans for these sites and any associated hazards, was reported to the EC. The legacy of uranium mines and mill tailing disposals in the EU are located mainly in 12 Member States where, in total, 87 tailing objects were identified at 63 sites. The volume of each one of these tailings disposal varies from a few thousand to several tens of million m{sup 3}. The majority of these sites are no longer in operation. More than 40 tailing embankments have already been completely remediated. Approximately 20 are currently being remediated while for the remaining objects, remediation has yet to start. After ten years, and for a few cases where the respective projects have not yet been completed, it seems that most of Europe's uranium mines and milling legacies were remediated according to acceptable environmental standards. Nevertheless, Europe is about to face a new challenge that comes from the concluded remediation projects for which an effective set of measures for coordinated institutional control, known as 'long-term stewardship', is needed including, in most cases, continuous and active maintenance. Moreover, the uncertainty of what will happen to these sites if institutional control fails at some point in time is a major concern. This work presents a summary of the situation and current issues of the uranium mine and mill tailings in Europe and their remediation status. It addresses not only the management of existing uranium mine and mill legacies but also the methods and strategies that have been used to prevent the creation of new future legacy sites from uranium mines still in operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Molecular beam epitaxial growth of metamorphic AlInSb/GaInSb high-electron-mobility-transistor structures on GaAs substrates for low power and high frequency applications

We report on molecular beam epitaxial growth of AlInSb/GaInSb metamorphic high-electron-mobility-transistor structures for low power, high frequency applications on 4 in. GaAs substrates. The structures consist of a Ga{sub 0.4}In{sub 0.6}Sb channel embedded in Al{sub 0.4}In{sub 0.6}Sb barrier layers which are grown on top of an insulating metamorphic buffer, which is based on the linear exchange of Ga versus In and a subsequent exchange of As versus Sb. Precise control of group V fluxes and substrate temperature in the Al{sub 0.4}In{sub 0.6}As{sub 1-x}Sb{sub x} buffer is essential to achieve high quality device structures. Good morphological properties were achieved demonstrated by the appearance of crosshatching and root mean square roughness values of 2.0 nm. Buffer isolation is found to be >100 k{Omega}/{open_square} for optimized growth conditions. Hall measurements at room temperature reveal electron densities of 2.8x10{sup 12} cm{sup -2} in the channel at mobility values of 21.000 cm{sup 2}/V s for single-sided Te volume doping and 5.4x10{sup 12} cm{sup -2} and 17.000 cm{sup 2}/V s for double-sided Te {delta}-doping, respectively.

36 MATERIALS SCIENCE↗

Investigation of realistic PET simulations incorporating tumor patient's specificity using anthropomorphic models: Creation of an oncology database

Purpose: The GATE Monte Carlo simulation toolkit is used for the implementation of realistic PET simulations incorporating tumor heterogeneous activity distributions. The reconstructed patient images include noise from the acquisition process, imaging system's performance restrictions and have limited spatial resolution. For those reasons, the measured intensity cannot be simply introduced in GATE simulations, to reproduce clinical data. Investigation of the heterogeneity distribution within tumors applying partial volume correction (PVC) algorithms was assessed. The purpose of the present study was to create a simulated oncology database based on clinical data with realistic intratumor uptake heterogeneity properties.Methods: PET/CT data of seven oncology patients were used in order to create a realistic tumor database investigating the heterogeneity activity distribution of the simulated tumors. The anthropomorphic models (NURBS based cardiac torso and Zubal phantoms) were adapted to the CT data of each patient, and the activity distribution was extracted from the respective PET data. The patient-specific models were simulated with the Monte Carlo Geant4 application for tomography emission (GATE) in three different levels for each case: (a) using homogeneous activity within the tumor, (b) using heterogeneous activity distribution in every voxel within the tumor as it was extracted from the PET image, and (c) using heterogeneous activity distribution corresponding to the clinical image following PVC. The three different types of simulated data in each case were reconstructed with two iterations and filtered with a 3D Gaussian postfilter, in order to simulate the intratumor heterogeneous uptake. Heterogeneity in all generated images was quantified using textural feature derived parameters in 3D according to the ground truth of the simulation, and compared to clinical measurements. Finally, profiles were plotted in central slices of the tumors, across lines with heterogeneous activity distribution for visual assessment.Results: The accuracy of the simulated database was assessed against the original clinical images. The PVC simulated images matched the clinical ones best. Local, regional, and global features extracted from the PVC simulated images were closest to the clinical measurements, with the exception of the size zone variability and the mean intensity values, where heterogeneous tumors showed better reproducibility. The profiles on PVC simulated tumors after postfiltering seemed to represent the more realistic heterogeneous regions with respect to the clinical reference.Conclusions: In this study, the authors investigated the input activity map heterogeneity in the GATE simulations of tumors with heterogeneous activity distribution. The most realistic heterogeneous tumors were obtained by inserting PVC activity distributions from the clinical image into the activity map of the simulation. Partial volume effect (PVE) can play a crucial role in the quantification of heterogeneity within tumors and have an important impact on applications such as patient follow-up during treatment and assessment of tumor response to therapy. The development of such a database incorporating patient anatomical and functional variability can be used to evaluate new image processing or analysis algorithms, while providing control of the ground truth, which is not available when dealing with clinical datasets. The database includes all images used and generated in this study, as well as the sinograms and the attenuation phantoms for further investigation. It is freely available to the interested reader of the journal at http://www.med.upatras.gr/oncobase/.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Radiotherapy in the Treatment of Oropharyngeal Cancer: An Update of the Memorial Sloan-Kettering Cancer Center Experience

Purpose: To update the Memorial Sloan-Kettering Cancer Center's experience with intensity-modulated radiotherapy (IMRT) in the treatment of oropharyngeal cancer (OPC). Methods and Materials: Between September 1998 and April 2009, 442 patients with histologically confirmed OPC underwent IMRT at our center. There were 379 men and 63 women with a median age of 57 years (range, 27-91). The disease was Stage I in 2%, Stage II in 4%, Stage III in 21%, and Stage IV in 73% of patients. The primary tumor subsite was tonsil in 50%, base of tongue in 46%, pharyngeal wall in 3%, and soft palate in 2%. The median prescription dose to the planning target volume of the gross tumor was 70 Gy for definitive (n = 412) cases and 66 Gy for postoperative cases (n = 30). A total 404 patients (91%) received chemotherapy, including 389 (88%) who received concurrent chemotherapy, the majority of which was platinum-based. Results: Median follow-up among surviving patients was 36.8 months (range, 3-135). The 3-year cumulative incidence of local failure, regional failure, and distant metastasis was 5.4%, 5.6%, and 12.5%, respectively. The 3-year OS rate was 84.9%. The incidence of late dysphagia and late xerostomia {>=}Grade 2 was 11% and 29%, respectively. Conclusions: Our results confirm the feasibility of IMRT in achieving excellent locoregional control and low rates of xerostomia. According to our knowledge, this study is the largest report of patients treated with IMRT for OPC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-D-9A-02: Automated Landmark-Guided CT to Cone-Beam CT Deformable Image Registration

Purpose: The anatomical changes that occur between the simulation CT and daily cone-beam CT (CBCT) are investigated using an automated landmark-guided deformable image registration (LDIR) algorithm with simultaneous intensity correction. LDIR was designed to be accurate in the presence of tissue intensity mismatch and heavy noise contamination. Method: An auto-landmark generation algorithm was used in conjunction with a local small volume (LSV) gradient matching search engine to map corresponding landmarks between the CBCT and planning CT. The LSVs offsets were used to perform an initial deformation, generate landmarks, and correct local intensity mismatch. The landmarks act as stabilizing controlpoints in the Demons objective function. The accuracy of the LDIR algorithm was evaluated on one synthetic case with ground truth and data of ten head and neck cancer patients. The deformation vector field (DVF) accuracy was accessed using a synthetic case. The Root mean square error of the 3D canny edge (RMSECE), mutual information (MI), and feature similarity index metric (FSIM) were used to access the accuracy of LDIR on the patient data. The quality of the corresponding deformed contours was verified by an attending physician. Results: The resulting 90 percentile DVF error for the synthetic case was within 5.63mm for the original demons algorithm, 2.84mm for intensity correction alone, 2.45mm using controlpoints without intensity correction, and 1.48 mm for the LDIR algorithm. For the five patients the mean RMSECE of the original CT, Demons deformed CT, intensity corrected Demons CT, control-point stabilized deformed CT, and LDIR CT was 0.24, 0.26, 0.20, 0.20, and 0.16 respectively. Conclusion: LDIR is accurate in the presence of multimodal intensity mismatch and CBCT noise contamination. Since LDIR is GPU based it can be implemented with minimal additional strain on clinical resources. This project has been supported by a CPRIT individual investigator award RP11032.

60 APPLIED LIFE SCIENCES↗

Theory and Modeling of Petawatt Laser Pulse Propagation in Low Density Plasmas

Report describing accomplishments in all-optical control of self-injection in laser-plasma accelerators and in developing advanced numerical models of laser-plasma interactions. All-optical approaches to controlling electron self-injection and beam formation in laser-plasma accelerators (LPAs) were explored. It was demonstrated that control over the laser pulse evolution is the key ingredient in the generation of low-background, low-phase-space-volume electron beams. To this end, preserving a smooth laser pulse envelope throughout the acceleration process can be achieved through tuning the phase and amplitude of the incident pulse. A negative frequency chirp compensates the frequency red-shift accumulated due to wake excitation, preventing evolution of the pulse into a relativistic optical shock. This reduces the ponderomotive force exerted on quiescent plasma electrons, suppressing expansion of the bubble and continuous injection of background electrons, thereby reducing the charge in the low-energy tail by an order of magnitude. Slowly raising the density in the pulse propagation direction locks electrons in the accelerating phase, boosting their energy, keeping continuous injection at a low level, tripling the brightness of the quasi-monoenergetic component. Additionally, propagating the negatively chirped pulse in a plasma channel suppresses diffraction of the pulse leading edge, further reducing continuous injection. As a side effect, oscillations of the pulse tail may be enhanced, leading to production of low-background, polychromatic electron beams. Such beams, consisting of quasi-monoenergetic components with controllable energy and energy separation, may be useful as drivers of polychromatic x-rays based on Thomson backscattering. These all-optical methods of electron beam quality control are critically important for the development of future compact, high-repetition-rate, GeV-scale LPA using 10 TW-class, ultra-high bandwidth pulses and mm-scale, dense plasmas. These results emphasize that investment into new pulse amplification techniques allowing for ultrahigh frequency bandwidth is as important for the design of future LPA as are the current efforts directed to increasing the pulse energy.

43 PARTICLE ACCELERATORS↗

Microgreens Food Safety Evaluation

Microgreens have been recently identified as a new type of pick and eat salad crop that can be utilized in space crop production systems. The majority of traditionally grown leafy green crops can be grown as microgreens, in addition to crops such as legumes (e.g. pea shoots), sunflower, buckwheat, most herbs, and corn, presenting hundreds of microgreen crop options. With a wide variety of flavors, exceptional nutritional density, short growth cycles (7-14 days), and unmatched volume optimization potential, microgreens present as an interesting option for sustainable production of nutritious and flavorful crops in space. The food safety aspects of microgreens have been investigated by USDA in recent years, however, an assessment for crew consumption purposes has not yet been conducted to capture the variety of microgreen cultivar types grown in spaceflight relevant environmental conditions and hardware that could be a part of the astronaut diet. Seed sanitation methods will be developed for each microgreen cultivar to sanitize the seed coat and ensure viable germination and plant growth. Food safety analysis will be performed on 24 different fast-growing cultivars of microgreens by performing aerobic plate counts (APC), fungal counts, and select pathogen screening of edible plant tissue before and after treatment with ProSan sanitizing produce wash. Additional avenues of investigation into microgreens food safety will be undertaken to understand impacts of plant height at time of harvest (able to be manipulated by light spectrum), seed density at time of planting, and role of blue light in food safety metrics of microgreens (n=6-12 microgreen cultivars tested, depending on variable). These findings will be included in the Space Crop Production Hazard Analysis Critical Control Point (HACCP) plan. This new work is currently postponed due to Covid-19.

M E Hummerick↗

SeaWiFS technical report series. Volume 15: The simulated SesWiFS data set, version 2

This document describes the second version of the simulated SeaWiFS data set. A realistic simulated data set is essential for mission readiness preparations and can potentially assist in all phases of ground support for a future mission. The second version improves on the first version primarily through additional realism and complexity. This version incorporates a representation of virtually every aspect of the flight mission. Thus, it provides a high-fidelity data set for testing several aspects of the ground system, including data acquisition, data processing, data transfers, calibration and validation, quality control, and mission operations. The data set is constructed for a seven-day period, 25-31 March 1994. Specific features of the data set include Global Area coverage (GAC), recorded Local Area Coverage (LAC), and realtime High Resolution Picture Transmission (HRPT) data for the seven-day period. A realistic orbit, which is propagated using a Brouwer-Lyddane model with drag, is used to simulate orbit positions. The simulated data corresponds to the command schedule based on the orbit for this seven-day period. It includes total (at-satellite) radiances not only for ocean, but for land, clouds, and ice. The simulation also utilizes a high-resolution land-sea mask. It includes the April 1993 SeaWiFS spectral responses and sensor saturation responses. The simulation is formatted according to July 1993 onboard data structures, which include corresponding telemetry (instrument and spacecraft) data. The methods are described and some examples of the output are given. The instrument response functions made available in April 1993 have been used to produce the Version 2 simulated data. These response functions will change as part of the sensor improvements initiated in July-August 1993.

Hooker, Stanford B.↗

Dose-shaping using targeted sparse optimization

Purpose: Dose volume histograms (DVHs) are common tools in radiation therapy treatment planning to characterize plan quality. As statistical metrics, DVHs provide a compact summary of the underlying plan at the cost of losing spatial information: the same or similar dose-volume histograms can arise from substantially different spatial dose maps. This is exactly the reason why physicians and physicists scrutinize dose maps even after they satisfy all DVH endpoints numerically. However, up to this point, little has been done to control spatial phenomena, such as the spatial distribution of hot spots, which has significant clinical implications. To this end, the authors propose a novel objective function that enables a more direct tradeoff between target coverage, organ-sparing, and planning target volume (PTV) homogeneity, and presents our findings from four prostate cases, a pancreas case, and a head-and-neck case to illustrate the advantages and general applicability of our method.Methods: In designing the energy minimization objective (E{sub tot}{sup sparse}), the authors utilized the following robust cost functions: (1) an asymmetric linear well function to allow differential penalties for underdose, relaxation of prescription dose, and overdose in the PTV; (2) a two-piece linear function to heavily penalize high dose and mildly penalize low and intermediate dose in organs-at risk (OARs); and (3) a total variation energy, i.e., the L{sub 1} norm applied to the first-order approximation of the dose gradient in the PTV. By minimizing a weighted sum of these robust costs, general conformity to dose prescription and dose-gradient prescription is achieved while encouraging prescription violations to follow a Laplace distribution. In contrast, conventional quadratic objectives are associated with a Gaussian distribution of violations, which is less forgiving to large violations of prescription than the Laplace distribution. As a result, the proposed objective E{sub tot}{sup sparse} improves tradeoff between planning goals by 'sacrificing' voxels that have already been violated to improve PTV coverage, PTV homogeneity, and/or OAR-sparing. In doing so, overall plan quality is increased since these large violations only arise if a net reduction in E{sub tot}{sup sparse} occurs as a result. For example, large violations to dose prescription in the PTV in E{sub tot}{sup sparse}-optimized plans will naturally localize to voxels in and around PTV-OAR overlaps where OAR-sparing may be increased without compromising target coverage. The authors compared the results of our method and the corresponding clinical plans using analyses of DVH plots, dose maps, and two quantitative metrics that quantify PTV homogeneity and overdose. These metrics do not penalize underdose since E{sub tot}{sup sparse}-optimized plans were planned such that their target coverage was similar or better than that of the clinical plans. Finally, plan deliverability was assessed with the 2D modulation index.Results: The proposed method was implemented using IBM's CPLEX optimization package (ILOG CPLEX, Sunnyvale, CA) and required 1-4 min to solve with a 12-core Intel i7 processor. In the testing procedure, the authors optimized for several points on the Pareto surface of four 7-field 6MV prostate cases that were optimized for different levels of PTV homogeneity and OAR-sparing. The generated results were compared against each other and the clinical plan by analyzing their DVH plots and dose maps. After developing intuition by planning the four prostate cases, which had relatively few tradeoffs, the authors applied our method to a 7-field 6 MV pancreas case and a 9-field 6MV head-and-neck case to test the potential impact of our method on more challenging cases. The authors found that our formulation: (1) provided excellent flexibility for balancing OAR-sparing with PTV homogeneity; and (2) permitted the dose planner more control over the evolution of the PTV's spatial dose distribution than conventional objective functions. In particular, E{sub tot}{sup sparse}-optimized plans for the pancreas case and head-and-neck case exhibited substantially improved sparing of the spinal cord and parotid glands, respectively, while maintaining or improving sparing for other OARs and markedly improving PTV homogeneity. Plan deliverability for E{sub tot}{sup sparse}-optimized plans was shown to be better than their associated clinical plans, according to the two-dimensional modulation index.Conclusions: These results suggest that our formulation may be used to improve dose-shaping and OAR-sparing for complicated disease sites, such as the pancreas or head and neck. Furthermore, our objective function and constraints are linear and constitute a linear program, which converges to the global minimum quickly, and can be easily implemented in treatment planning software. Thus, the authors expect fast translation of our method to the clinic where it may have a positive impact on plan quality for challenging disease sites.

61 RADIATION PROTECTION AND DOSIMETRY↗

FEM modeling of plastic flow and strain-induced phase transformation in BN under high pressure and large shear in a rotational diamond anvil cell

In this study, combined three-dimensional plastic flow and strain-induced phase transformation (PT) in boron nitride (BN) under high pressure and large shear in a rotational diamond anvil cell (rotational DAC or RDAC) are investigated. Geometrically nonlinear frameworks including finite elastic, transformational, and plastic deformations and finite element method (FEM) are utilized. Quantitative information is obtained on the evolutions of the stress tensor, plastic strain, volume fraction of phases in the entire sample, and slip-cohesion transitions, all during torsion under a fixed compressive load in RDAC. The effects of the applied compressive stress and the sample radius on PT and plastic flow are discussed. In comparison with DAC, the same amount of the high-pressure phase can be obtained at a much lower pressure in RDAC, which reduces the required force and the risk of diamond fracture. Also, RDAC has a potential to complete PT during torsion under pressure close to the minimum possible. A quasi-homogeneous pressure can be obtained in a transforming sample in RDAC under a proper choice of properties and parameters of a gasket. A number of experimental phenomena, including the pressure self-multiplication and quasi-homogeneous pressures in DAC and RDAC, are reproduced and interpreted. Finally, the simulation results provide a significant insight into coupled PTs and plastic flow in material in RDAC, and are important for the optimum design of experiments and the extraction of material parameters for PT, as well as for the optimization and control of PTs by the variation of various parameters.

36 MATERIALS SCIENCE↗

Accelerated Partial Breast Irradiation Is Safe and Effective Using Intensity-Modulated Radiation Therapy in Selected Early-Stage Breast Cancer

Purpose: To report the feasibility, toxicity, cosmesis, and efficacy of using intensity-modulated radiation therapy (IMRT) with respiratory gating to deliver accelerated partial breast irradiation (APBI) in selected Stage I/II breast cancer after breast-conserving surgery. Methods and Materials: Eligible patients with node-negative Stage I/II breast cancer were prospectively enrolled in an institutional review board approved protocol to receive APBI using IMRT after breast-conserving surgery. The target volume was treated at 3.8 Gy/fraction twice daily for 5 days, to a total dose of 38 Gy. Results: Thirty-six patients were enrolled for a median follow-up time of 44.8 months. The median tumor size was 0.98 cm (range, 0.08-3 cm). The median clinical target volume (CTV) treated was 71.4 cc (range, 19-231 cc), with the mean dose to the CTV being 38.96 Gy. Acute toxicities included Grade 1 erythema in 44% of patients and Grade 2 in 6%, Grade 1 hyperpigmentation in 31% of patients and Grade 2 in 3%, and Grade 1 breast/chest wall tenderness in 14% of patients. No Grade 3/4 acute toxicities were observed. Grade 1 and 2 late toxicities as edema, fibrosis, and residual hyperpigmentation occurred in 14% and 11% of patients, respectively; Grade 3 telangiectasis was observed in 3% of patients. The overall cosmetic outcome was considered 'excellent' or 'good' by 94% of patients and 97% when rated by the physician, respectively. The local control rate was 97%; 1 patient died of a non-cancer-related cause. Conclusions: APBI can be safely and effectively administered using IMRT. In retrospective analysis, IMRT enabled the achievement of normal tissue dose constraints as outlined by Radiation Therapy Oncology Group 04-13/NSABP B-13 while providing excellent conformality for the CTV. Local control and cosmesis have remained excellent at current follow-up, with acceptable rates of acute/late toxicities. Our data suggest that cosmesis is dependent on target volume size. Further prospective multi-institutional trials should be performed to evaluate IMRT to deliver APBI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-BRD-11: A Virtual Simulator Designed for Collision Prevention in Proton Therapy

Purpose: In proton therapy, collisions between patient and nozzle potentially occur in attaining minimal air gap due to the large nozzle structure. Thus, we developed software predicting the collisions of the nozzle and patient by simulating treatments. Methods: 3D modeling of a gantry inner-floor, nozzle and robotic-couch was done by using the SolidWorks based on the manufacturer’s machine data. To obtain patient body information, a 3D-scanner was utilized to scan a patient right before CT scanning. From the acquired images, a 3D-image of the patient’s body contour was reconstructed. The accuracy of the image was confirmed against the CT image for a humanoid phantom. The machine components and the virtual patient were combined on the treatment-room coordinate system, resulting in a virtual simulator. The simulator simulated the motion of its components such as rotation and translation of gantry, nozzle and couch, in real scale. Collision, if any, was examined both in static mode and dynamic mode. The static mode checks only at fixed positions of the machine’s components while dynamic mode examines while one component is in motion. Collision was notified if any voxel of two components, for example a nozzle and a patient or couch, overlapped when calculating volume locations. The event and collision point are visualized and colliding volumes are reported. Results: All components were successfully assembled and the motions could be accurately controlled. The 3D-shape of a phantom agreed with CT images within a deviation of 2 mm. Collision situations can be simulated within minutes and the results are displayed and reported. Conclusion: The developed software will be useful in improving patient safety and clinical efficiency for proton therapy. This work was supported by the National Research Foundation of Korea funded by Ministry of Science, ICT & Future Planning (2012M3A9B6055201, 2013M2A2A7043507), and Samsung Medical Center grant (GFO1130081)

60 APPLIED LIFE SCIENCES↗