Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “charged”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Estimate of Lorentz force effects on charged particles

Thermonuclear (TN) fusion reaction between deutrons are D + D → T + P D + D → 3 He + n where P is the proton, D is the deuteron, T is the triton, n is the neutron, and 3 He is the helion. They are born with high energies (0.82 MeV for 3 He, 1.01 MeV for T, 3.02 MeV for P, and 2.45 MeV for n). The charged particles slow down due to the drag force (stopping power). While slowing down, the charged particles deposit their energy, which may affect the TN burn characteristics. When magnetic field is present, the velocity of the charged particle would be affected due to the Lorentz force, which can affect the stopping of the charged particle. As a consequence, TN burn characteristics may change, Our purpose is to asses the importance of the Lorentz force in stopping of the charged particle, based on a simple comparison between the Lorentz force and stopping power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of an Extreme Fast Charging Battery

The objective of the project is to research, develop, design, fabricate, and demonstrate extreme fast charging (XFC) Li-ion cells capable of a 10 min charge to deliver 180Wh/kg at the beginning of life (BoL) and sustain >500 XFC cycles with less than 20% capacity loss. The PI developed an asymmetric temperature modulation (ATM) charging strategy that charges a Li-ion cell at an elevated temperature of ~60oC and discharges at the ambient temperature. The elevated charging temperature eliminates Li plating, while the limited exposure time to 60oC effectively controls materials degradation, thereby enabling XFC with remarkable battery life. We developed and demonstrated 209 and 271 Wh/kg cells, both of which exceed the afore-mentioned target of delivering 180Wh/kg at BoL and sustaining 500+ XFC cycles with less than 20% loss.

25 ENERGY STORAGE↗

Impacts of Increasing Electrification on State Fleet Operations and Charging Demand

State fleets represent an enticing opportunity to explore the near-term feasibility of fleet electrification. In many instances, state fleet operations encompass a wide geographic area with fleet locations for many vehicles. Serving these wide areas will require a significant amount of energy and, in the case of electric vehicles (EVs), a significant level of charging power. The peak demand as a result of this charging demand is of interest for fleets, with impacts on both utility bills and installation costs ranking among some of the greatest concerns. The combination of a wide operational area and multiple fleet locations positions state fleets as ideal candidates to understand the impacts of vehicle charging on fleet operations. As the availability of electric drivetrains expands beyond light-duty sedans, fleets need to understand when it will be appropriate operationally and financially to start adding electric drivetrains to their fleets. Throughout this process, it will also be important to understand the charging implications of fleet electrification and the resulting impacts to facility electrical systems. To better understand these considerations, NREL contracted Sawatch Labs to analyze the role that increasing state fleet electrification may have on the charging demand at fleet parking facilities.

33 ADVANCED PROPULSION SYSTEMS↗

Spacecraft surface charging as a function of material properties

Spacecraft material behavior plays a very important role in space missions. Spacecraft immersed in plasma get charged by absorbing plasma particles and by emitting electrons from spacecraft surfaces via photoelectron and secondary electron emission. Spacecraft charging depends heavily on material properties such as work function, secondary electron yield, dielectric constant, and electric conductivity among other. Material properties are typically assumed to be static in charging models. However, it is well known that this is not the case in space. This makes spacecraft charging predictions very challenging. Material properties are well characterized before the spacecraft is put in orbit through characterization in the lab under clean conditions. However, once in space, material properties change due to the harsh and very dynamic space environment. We present a new capability to predict material behavior in space from first-principles modeling. The ongoing effort seeks to couple material models, density functional theory (DFT) and molecular dynamic (MD) codes, with environment models, plasma kinetic codes. This preliminary study will show results of surface charging as a function of material work function, dielectric constant, and conductivity.

36 MATERIALS SCIENCE↗

Solar Power + Electric Vehicle Charging: Capturing Synergies in Minnesota

Despite the state policy support, significant market barriers to decarbonization of transportation remain. Analysis conducted by the National Renewable Energy Laboratory (NREL) and others confirm that without routine access to charging infrastructure, both at home and in non-residential locations, bullish market forecasts are unlikely to materialize. Similarly, the expansion of EV charging and variable renewable energy deployment each have potentially disruptive and costly effects on the distribution grid. Finally, electrification of passenger vehicles is not enough to decarbonize transportation without pathways to carbon-free electrification, linking EV charging and clean energy generation. This document examines the opportunity to jointly deploy solar energy and EV charging infrastructure to capture synergistic value, mitigate for risks associated with integrating and scaling both solar and EV charging, and accelerate their mutual deployment.

14 SOLAR ENERGY↗

The Evolving Role of Demand Charges in Retail Electricity Rates

Retail electricity demand charges refer to a type of retail rate that is based on a metric of kilowatt (kW) demand rather than kilowatt-hour (kWh) energy usage. Demand charges are widely used in the commercial and industrial (C&I) electricity sectors to recover significant portions of utility revenue and are also used in residential rates in a modest but growing number of locations. This paper explores the historical context of and motivations for demand charges, describes their implementation and impacts in today's context, and uses a variety of opinions collected from relevant parties through semi-structured interviews to inform how demand charges align with four widely accepted rate design principles. This project is funded by the Department of Energy's Office of Electricity, which is interested in conducting research to understand the current state of affairs related to demand charges and how the future U.S. electricity grid will help to define retail rates.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Effect of Si Content on Extreme Fast Charging Behavior in Silicon–Graphite Composite Anodes

Commercial Li-ion batteries typically incorporate a small amount of high-capacity silicon (Si)-based materials in the composite graphite-based anode to increase the energy density of the battery. However, very little is known about the effects of Si on the fast-charging behavior of composite anodes. Herein, we examine the effects of the Si/graphite ratio in the composite anode on the fast-charging behavior of full cells. We show that addition of Si increases the rate capability from 1C to 8C and improves the capacity retention in early cycles at 6C due to reduced overpotential in constant current charging cycles. The impacts of Si content on fast-charging aging were identified by Post-Test characterization. Despite realizing benefits of available capacity and reduced Li plating at 6C, silicon–electrolyte interactions lead the time-dependent cell performance to fade quickly in the long term. The Post-Test analysis also revealed the thickening of the electrode and nonuniform distribution of electrolyte decomposition products on the Si-containing anodes, as well as the organic-rich solid electrolyte interphase (SEI), which are the factors behind cell degradation. Our study sheds insight on the advantages and disadvantages of Si/graphite composite anodes when they are used in fast-charging applications and guides further research in the area by designing an optimized composition of Si incorporated in a mature graphite matrix.

25 ENERGY STORAGE↗

Charged Grains and Kelvin–Helmholtz Instability in Molecular Clouds

The presence of dust grains profoundly affects the diffusion of the magnetic field in molecular clouds. When the electrons and ions are well coupled to the magnetic field and charged grains are only indirectly coupled, emergent Hall diffusion may dominate over all the other non-ideal magnetohydrodynamic (MHD) effects in a partially ionized dusty cloud. The low-frequency, long (∼0.01–1 pc) wavelength dispersive MHD waves will propagate in such a medium with the polarization of the waves determined by the dust charge density or the dust size distribution. In the presence of shear flows, these waves may become Kelvin–Helmholtz unstable with the dust charge density or the grain size distribution operating as a switch to the instability. When Hall diffusion time is long (compared to the time over which waves are sheared), the growth rate of the instability in the presence of sub-Alfvénic flow increases with the charge number |Z| on the grain, while it is quenched in the presence of Alfvénic or super-Alfvénic flows. However, when Hall diffusion is fast, the growth rate of the instability depends on the dust charge only indirectly.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of Initial Velocity on One-Dimensional, Ambipolar, Space-Charge Currents

Oppositely directed flows of positive and negative charges constitute an ambipolar current. A general case is analyzed in which the charges traverse the evacuated space between plane-parallel boundaries and all particles of a given charge species are monoenergetic. It is assumed that the charges may possess non-vanishing initial kinetic energy. This represents an extension of analyses by Langmuir and Muller-Lubeck for vanishing initial kinetic energy. Sample calculations of dimensionless current densities, electric and potential fields, and charge-density distributions are exhibited for cases where the electric field is assumed to vanish at one boundary but the species initial velocities may not. It is shown that resulting ion currents may be several times the Child's law limit if initial kinetic energies are of the order of the potential energy.

SPACE CHARGE↗

Impact of Charge Methodology upon the Performance of Lithium Ion Cells

This viewgraph gives an overview on the impact of charge methodology upon the performance of lithium ion cells. Charge characteristics are given on the following: (1) lithium ion prototype cells, including charge rate characteristics at different temperatures, the effect of charge methodology upon cycle life performance, the effect of charge voltage upon cell performance; (2) three-electrode cells; and (3) lithium-ion eight-cell batteries.

lithium ion cells↗

Solar Absorptivity Degradation of Spacecraft Materials Due to UV and Charged Particles in the Gateway Environment

The Gateway Passive Thermal Control System (PTCS) Group has identified charged particle and UV degradation of Gateway materials as a knowledge gap for the Near Rectilinear Halo Orbit (NRHO) and transit environment. Candidate materials and coatings were subjected to expected mission UV and charged particle environments at NASA Goddard Space Flight Center (GSFC). In situ change in reflectivity was observed at specified intervals during testing such that change in solar absorptivity could be plotted as a function of time of solar exposure. Gateway will be an outpost in cislunar space designed to survive a 15-year mission to support human moon landings and future deep space exploration. The Gateway Passive Thermal Control System (PTCS) Group has identified charged particle and UV degradation of potential Gateway materials as a knowledge gap for the Near Rectilinear Halo Orbit (NRHO) and transit environment, especially the slow spiral transit planned for the first two modules. Solar absorptivity degradation is important to quantify because the end-of-life absorptivity impacts thermal performance of the system. To address this, ground testing is being completed at NASA Goddard Space Flight Center in which potential Gateway materials, including radiators, multi-layer insulation (MLI), and structural materials are subjected to the expected transit plus 15-year on-orbit charged particle fluence (9.86x1015 protons/cm2 at 2.5 keV and 3.1x1016 electrons/cm2 at 10 keV) and up to 5000 Equivalent Solar Hours (ESH). Reflectivity of a single sample of each material was measured in atmosphere and in vacuum inside the chamber after exposure to incremental levels of ESH and charged particle fluence. Increase in absorptivity of most samples were seen throughout the test including large differences in absorptivity of materials of the same category. Future testing will validate these results and include additional materials of interest.

materials in the space environment↗

U.S. Department of Energy's EV Everywhere Workplace Charging Challenge, Mid-Program Review: Employees Plug In

This Program Review takes an unprecedented look at the state of workplace charging in the United States -- a report made possible by U.S. Department of Energy leadership and valuable support from our partners as they share their progress in developing robust workplace charging programs. Through the Workplace Charging Challenge, more than 250 participants are accelerating the development the nation's worksite PEV charging infrastructure and are supporting cleaner, more convenient transportation options within their communities. Challenge partners are currently providing access to PEV charging stations at more than 440 worksites across the country and are influencing countless other organizations to do the same.

33 ADVANCED PROPULSION SYSTEMS↗

Effects of Electric Vehicle Fast Charging on Battery Life and Vehicle Performance

As part of the U.S. Department of Energy’s Advanced Vehicle Testing Activity, four new 2012 Nissan Leaf battery electric vehicles were instrumented with data loggers and operated over a fixed on-road test cycle. Each vehicle was operated over the test route, and charged twice daily. Two vehicles were charged exclusively by AC level 2 EVSE, while two were exclusively DC fast charged with a 50 kW charger. The vehicles were performance tested on a closed test track when new, and after accumulation of 50,000 miles. The traction battery packs were removed and laboratory tested when the vehicles were new, and at 10,000-mile intervals. Battery tests include constant-current discharge capacity, electric vehicle pulse power characterization test, and low peak power tests. The on-road testing was carried out through 70,000 miles, at which point the final battery tests were performed. The data collected over 70,000 miles of driving, charging, and rest are analyzed, including the resulting thermal conditions and power and cycle demands placed upon the battery. Battery performance metrics including capacity, internal resistance, and power capability obtained from laboratory testing throughout the test program are analyzed. Results are compared within and between the two groups of vehicles. Specifically, the impacts on battery performance, as measured by laboratory testing, are explored as they relate to battery usage and variations in conditions encountered, with a primary focus on effects due to the differences between AC level 2 and DC fast charging. The contrast between battery performance degradation and the effect on vehicle performance is also explored.

Electric Vehicle↗

Charge Management Optimization for Future TOU Rates: Preprint

The effectiveness of future time of use (TOU) rates to enable managed charging for providing demand response depends on the vehicle's flexibility and the benefits to owners. This paper adopts opportunity, delayed, and smart charging methods to quantify these impacts, flexibilities, and benefits. Simulation results show that delayed and smart charging methods can shift most charging events to lower TOU rate periods without compromising the charged energy and individual driver mobility needs.

25 ENERGY STORAGE↗

Charge Management Optimization for Future TOU Rates

The effectiveness of future time of use (TOU) rates to enable managed charging for providing demand response depends on the vehicle's flexibility and the benefits to owners. This paper adopts opportunity, delayed, and smart charging methods to quantify these impacts, flexibilities, and benefits. Simulation results show that delayed and smart charging methods can shift most charging events to lower TOU rate periods without compromising the charged energy and individual driver mobility needs.

25 ENERGY STORAGE↗

Battery Extreme Fast Charge: A Thermal Prospective

Battery extreme fast charging (XFC) has been identified as a necessity to further drive the market penetration of electric vehicles. Today's thermal management systems are unable to keep up with the added thermal load under extreme fast charge. Along with an upgrade in the thermal management system, the full battery pack will need to be designed to enable fast charging. This ranges from material level cell design to pack interconnect design to advanced thermal management systems. While thermal management is not a limiting condition to extreme fast charge, it will need to be considered to drive towards the fast charge cost and volume goals.

25 ENERGY STORAGE↗

Grid Voltage Control Analysis for Heavy-Duty Electric Vehicle Charging Stations: Preprint

This paper presents an analysis of voltage control strategies for heavy duty electric vehicle (EV) charging stations. The performance of three voltage control approaches including power factor control, preset volt-var curve control, and customized volt-var curve control, have been investigated and evaluated for three different sizes of charging stations, including single-port small charging station, three-port middle size charging station, and 6-port travel center. The charging stations have been placed on various locations of four different types of distribution systems, to obtain a comprehensive performance analysis of the three voltage control approaches under different scenarios. To quantitively compare the performance of the three voltage control approaches, a series of metrics have been designed to quantify the performance and contribute to the comprehensive analysis summary.

47 OTHER INSTRUMENTATION↗

Disrupting EV Charging Sessions and Gaining Remote Code Execution with DoS, MITM, and Code Injection Exploits using OCPP 1.6

Open Charge Point Protocol (OCPP) 1.6 is widely used in the electric vehicle (EV) charging industry to communicate between Charging System Management Services (CSMSs) and Electric Vehicle Supply Equipment (EVSE). Unlike OCPP 2.0.1, OCPP 1.6 uses unencrypted websocket communications to exchange information between EVSE devices and an onpremise or cloud-based CSMS. In this work, we demonstrate two machine-in-the-middle (MITM) attacks on OCPP sessions to terminate charging sessions and gain root access to the EVSE equipment via remote code execution (RCE). Second, we demonstrate a malicious firmware update with a code injection payload to compromise an EVSE. Lastly, we demonstrate two methods to prevent availability of the EVSE or CSMS. One of these, originally reported by SaiFlow, prevents traffic to legitimate EVSE equipment using a DoS-like attack on CSMSs by repeatedly connecting and authenticating several CPs with the same identities as the legitimate CP. These vulnerabilities were demonstrated with proof-of-concept exploits in a virtualized Cyber Range at Wright State University and/or with a 350 kW Direct Current Fast Charger (DCFC) at Idaho National Laboratory. The team found that OCPP 1.6 could be protected from these attacks by adding secure shell (SSH) tunnels to the protocol, if upgrading to OCPP 2.0.1 was not an option. Index Terms—Electric vehicle charging, cybersecurity, OCPP, cyberattack, cyber-resilience. INSPEC Accession Number: 23981565

99 GENERAL AND MISCELLANEOUS↗