Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Roadmap for the exposé of radiation flows (Xflows) experiment on $\mathrm{NIF}$

Here, the goal of the Xflows experimental campaign is to study the radiation flow on the National Ignition Facility (NIF) reproducing the sensitivity of the temperature (±8 eV, ±23 μm) and density (±11 mg/cc) measurements of the COAX platform. This new platform will enable future astrophysical experiments involving supernova shock breakout, such as Radishock on OMEGA-60, and stochastic media (such as XFOL on OMEGA). Greater energy and larger physical scale on NIF will enable a greater travel distance of radiation flow, higher density, and more manufacturable foams and enable exploration of a greater range of radiation behavior than achievable in the prior OMEGA experiments. This publication will describe the baseline configuration for the Xflows experimental campaign and the roadmap to achieve its primary objectives.

47 OTHER INSTRUMENTATION↗

Comparison of Single-Event Transients in an Epitaxial Silicon Diode Resulting from Heavy Ion-, Focused X-Ray-, and Pulsed Laser-Induced Charge Generation

Heavy ion, focused x-ray, and pulsed laser single event transient experiments are performed on a silicon epitaxial diode. Collected charge, transient rise times, and transient fall times are calculated and compared between the different sources. It is observed that these transient shape characteristics depend on the source (ion, x-ray, or laser), even when similar amounts of charge are generated. Finally, the observed differences are examined and explained in terms of basic charge collection mechanisms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Water window imaging x ray microscope

A high resolution x ray microscope for imaging microscopic structures within biological specimens has an optical system including a highly polished primary and secondary mirror coated with identical multilayer coatings, the mirrors acting at normal incidence. The coatings have a high reflectivity in the narrow wave bandpass between 23.3 and 43.7 angstroms and have low reflectivity outside of this range. The primary mirror has a spherical concave surface and the secondary mirror has a spherical convex surface. The radii of the mirrors are concentric about a common center of curvature on the optical axis of the microscope extending from the object focal plane to the image focal plane. The primary mirror has an annular configuration with a central aperture and the secondary mirror is positioned between the primary mirror and the center of curvature for reflecting radiation through the aperture to a detector. An x ray filter is mounted at the stage end of the microscope, and film sensitive to x rays in the desired band width is mounted in a camera at the image plane of the optical system. The microscope is mounted within a vacuum chamber for minimizing the absorption of x rays in air from a source through the microscope.

Hoover, Richard B.↗

Focal plane transport assembly controls for the High Energy Astronomy Observatory X-ray telescope

The High Energy Astronomy Observatory - Mission B (HEAO-B) is a satellite observatory for the purpose of performing a detailed X-ray survey of the celestial sphere. Measurements will be made of stellar radiation in the range of 0.2 to 20 keV. The central part of the Observatory is an X-ray telescope, into the focus of which a variety of imaging instruments and spectrographs may be introduced. The telescope has a resolution of about 1 arc second, so that the instruments must be placed with extreme precision. This is obtained by a mechanical system of toggles and stops and a motor drive system controlled by a position sensing potentiometer with a resolution of about 1.5 degrees

Carpenter, C.↗

X-ray emission from chemically peculiar stars

We have searched the Roentgen Satellite (ROSAT) All-Sky Survey (RASS) database at the positions of about 100 magnetic Bp-Ap stars of the helium-strong, helium-weak, silicon, and strontium-chromium subclasses. We detect X-ray sources at the positions of 10 of these stars; in four cases the X-ray emission presumably arises from an early-type companion with a radiatively driven wind, while we believe that the magnetic chemically peculiar (CP) star is the most likely X-ray source (as opposed to a binary companion) in at least three and at most five of the six remaining cases. The helium-strong stars have X-ray emission levels that are characteristic of the luminous OB stars with massive winds (log L(sub x)/L(sub bol) is about -7), whereas the He-weak and Si stars (which generally show no evidence for significant mass loss) have log L(sub x)/L(sub bol) values that can reach as high as about -6. In contrast, we find no convincing evidence that the cooler SrCrEu-type CP stars are intrinsic X-ray sources. We discuss the X-ray and radio emission properties of our sample of CP stars, and argue that both types of emission may be magnetospheric in origin; however, there is clearly not a simple one-to-one correspondence between them, since many of the magnetic stars that are detected radio sources were not detected as X-ray sources in the present survey.

Drake, S. A.↗

Investigating SLIM Disk Solutions FOR HLX-1 IN ESO 243-49

The hyperluminous X-ray source HLX-1 in the galaxy ESO 243-49, currently the best intermediate-mass blackhole (BH) candidate, displays spectral transitions similar to those observed in Galactic BH binaries, but with aluminosity 100-1000 times higher. We investigated the X-ray properties of this unique source by fitting multiepochdata collected by Swift, XMM-Newton, and Chandra with a disk model computing spectra for a wide rangeof sub- and super-Eddington accretion rates assuming a non-spinning BH and a face-on disk (i=0 deg.). Under theseassumptions we find that the BH in HLX-1 is in the intermediate-mass range (approximately 2 x 10(exp 4) solar mass) and the accretionflow is in the sub-Eddington regime. The disk radiation efficiency is eta = 0.11 plus or minus 0.03. We also show that the source does follow the LX is proportional to T(exp 4) relation for our mass estimate. At the outburst peaks, the source radiates near the Eddington limit. The accretion rate then stays constant around 4 x 10(exp 4) solar mass yr (sup -1) for several days and then decreases exponentially. Such plateaus in the accretion rate could be evidence that enhanced mass-transfer rateis the driving outburst mechanism in HLX-1. We also report on the new outburst observed in 2011 August by theSwift X-Ray Telescope. The time of this new outburst further strengthens the approximately 1 year recurrence timescale.

solutions↗

Radiation Exposure of Selected Composites and Thin Films

The effect of electron radiation on selected candidate composite materials was investigated. Radiation damage mechanisms were identified and the coefficient of thermal expansion were measured for each type composite material. It was concluded that the threshold for major physical and mechanical property changes in the polysulfone films and in the polysulfone and epoxy composites is in excess of 1 x 10 to the 9th power rads of electrons. Based upon these data, the 5208 and 934 epoxies and the P1700 polysulfone composites would be acceptable for 5 to 10 year geosynchronous Earth environment missions receiving 1 x 10 to the 9th power rads of electron radiation.

Wayne S Slemp↗

Constrained non-negative matrix factorization enabling real-time insights of in situ and high-throughput experiments

Non-negative matrix factorization (NMF) is an appealing class of methods for performing unsupervised learning on streaming spectral data, particularly in time-sensitive applications such as in situ characterization of materials. These methods seek to decompose a dataset into a small number of components and weights that can compactly represent the underlying signal while effectively reconstructing the observations with minimal error. However, canonical NMF methods have no underlying requirement that the reconstruction uses components or weights that are representative of the true physical processes. In this work, we demonstrate how constraining a subset of the NMF weights or components as rigid priors, provided as known or assumed values, can provide significant improvement in revealing true underlying phenomena. We present a PyTorch-based method for efficiently applying constrained NMF and demonstrate its application to several synthetic examples. Our implementation allows an expert researcher-in-the-loop to provide and dynamically adjust the constraints during a live experiment involving streaming spectral data. Such interactive priors allow researchers to specify known or identified independent components, as well as functional expectations about the mixing or transitions between the components. We further demonstrate the application of this method to measured synchrotron x-ray total scattering data from in situ beamline experiments. In such a context, constrained NMF can result in a more interpretive and scientifically relevant decomposition than canonical NMF or other decomposition techniques. As a result, the details of the method are provided, along with general guidance for employing constrained NMF in the extraction of critical information and insights during time-sensitive experimental applications.

36 MATERIALS SCIENCE↗

Remote sensing estimates of cirrus particle size for tropical and midlatitude cirrus: Hexagonal crystals and ice spheres

A large discrepancy exists in current estimates of a mean cirrus particle size appropriate for calculations of the effects of these ice clouds on solar and thermal infrared radiative fluxes. For spheres with large size parameter (x = (2 pi r / lambda) is greater than 30, where r is particle radius), and moderate absorption (n(sup i) x less than 1, where n(sup i) is imaginary index of refraction for ice), the optimal effective particle radius is given by: r(sub e) = integral of r(exp 3)n(r)dr / integral of r(exp 2)n(r)dr. For the remote sensing of cirrus particle size at wavelengths of 0.83, 1.65, and 2.21 mu m, a 50 mu m ice sphere would have a size parameter of about 200, and values of n(sup i) x of 0, 0.045, and 0.06, satisfying the above conditions. However, while r(sub e) is a well-defined parameter for spheres, this cross-section area-weighted particle radius can only be extended to non-spherical particles by defining some equivalent sphere, typically an equivalent volume or equivalent cross-section area sphere. Using equivalent volume spheres, values of r(sub e) obtained over Lake Michigan on October 28, 1986, during FIRE phase I varied from 200 mu m (King Air 2D Imaging probes) to 60 mu m (Landsat reflectances at 0.83, 1.65, and 2.2 mu m), to 25 mu m (HIS spectrometer thermal emission between 8 and 12 mu m). Three major uncertainties were identified in this comparison: small ice particles missed by the 2D-C aircraft probes, uncertain ice refractive index, and uncertainties in the single scatter albedos and scattering phase functions used in the radiative calculations. Since the first FIRE cirrus results, advances have been made in all three areas. The present paper reports on improvements in the radiative modeling of ice particles at 0.83, 1.65, and 2.21 mu m wavelengths appropriate for comparisons to Landsat Thematic Mapper data. The paper also includes new results for Landsat observations of ice clouds in the eastern and western tropical Pacific.

Wielicki, Bruce A.↗

Expansion and Age of the X-Ray Synchrotron-Dominated Supernova Remnant G330.2+1.0

We report new Chandra observations of one of the few Galactic supernova remnants whose X-ray spectrum is dominated by nonthermal synchrotron radiation, G330.2+1.0. We find that between 2006 and 2017, some parts of the shell have expanded by about 1%, giving a free-expansion (undecelerated) age of about 1000 yr, and implying shock velocities there of 9000 km/s for a distance of 5 kpc. Somewhat slower expansion is seen elsewhere around the remnant periphery, in particular in compact knots. Because some deceleration must have taken place, we infer that G330.2+1.0 is less than about 1000 yr old. Thus, G330.2+1.0 is one of only four Galactic core-collapse remnants of the last millennium. The large size, low brightness, and young age require a very low ambient density, suggesting expansion in a stellar-wind bubble. We suggest that in the east, where some thermal emission is seen and expansion velocities are much slower, the shock has reached the edge of the cavity. The high shock velocities can easily accelerate relativistic electrons to X-ray-emitting energies. A few small regions show highly significant brightness changes by 10%–20%, both brightening and fading, a phenomenon previously observed in only two supernova remnants, indicating strong and/or turbulent magnetic fields.

Borkowski, Kazimierz J.↗

X-ray emission from white dwarfs.

It is suggested that both the 250-eV background radiation and the recently observed variations in the optical emission from certain white dwarfs may be due to thermal bremsstrahlung from hot coronae surrounding such stars. The X-ray flux from the variable white dwarfs is predicted and in the most favorable case, R548, is sufficiently large to allow an observational test of the model. The possibility that the variations observed in strong X-ray sources are due to pulsations in the coronae surrounding degenerate stars, rather than in stars themselves, is also discussed. For the white dwarfs, both pulsation and rotation of the central star are found to be adequate sources of coronal energy, with pulsation being subject to relatively easy observational test. The energy requirements for the strong X-ray sources are briefly discussed.

Strittmatter, P. A.↗

Source size of x rays from self-modulated laser wakefield accelerators

A comparative study of x-ray sources generated with different mechanisms from self-modulated laser wakefield acceleration (SM-LWFA) electrons was performed to compare the source size or spatial resolution for use in high energy density science applications. We examine the source size of betatron, inverse Compton scattering, and bremsstrahlung radiation with a Fresnel diffraction based formalism and a modified x-ray ray tracing model. We observe the dependence of source size on the radiation generation process, laser parameters, and compare to what is possible in other regimes of LWFA, as well as current methods. This information is significant as we begin to explore the use of light sources driven by SM-LWFA for use as a diagnostic at large-scale laser facilities where blowout regime LWFA is not possible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Induction of micronuclei in human fibroblasts across the Bragg curve of energetic heavy ions

The space environment consists of a varying field of radiation particles including high energy ions, with spacecraft shielding material providing the major protection to astronauts from harmful exposure. Unlike low-L or X-rays, the presence of shielding does not always reduce the radiation risks for energetic charged particle exposure. Although the dose delivered by the charged particle increases sharply as the particle approaches the Bragg peak, the Bragg curve does not necessarily represent the biological damage along the particle traversal. The "biological Bragg curve" is dependent on the energy and the type of the primary particle, and may vary for different biological endpoints. To investigate "biological Bragg curves", we analyzed micronuclei (MN) induction along the particle traversal of Si and Fe ions at incident energies of 300 MeV/nucleon and 1 GeV/nucleon. A quantitative biological response curve did not reveal an increased yield of MN at the location of the Bragg peak. However, the ratio of mono-to bi-nucleated cells, which indicates inhibition in cell progression, increased at the Bragg peak location. These results confirm the hypothesis that "over kill" at the Bragg peak will affect the outcome of other biological endpoints.

Hada, Megumi↗

Evidence that the X-Ray Plasma in Microflares is in a Sequence of Subresolution Magnetic Tubes

We analyze the cooling of the X-ray emitting thermal plasma in microflares observed in active regions by the Yohkoh Soft X-ray Telescope. A typical microflare appears to be a transient brightening of an entire small magnetic loop, often having a diameter near the limit of resolution (approximately 2 x 10(exp 8) cm) (Shimizu 1995, PASJ, 47, 251). The X-ray plasma in the loop cools by emission of XUV radiation and by heat conduction to the cooler plasma at the feet of the loop. The cooling rate is determined by the plasma temperature and density and the loop length. The plasma density is determined from the observed X-ray brightness of the loop in combination with the temperature, the loop diameter, and the filling factor. The filling factor is the volume fraction of the loop occupied by the subset of magnetic tubes that is filled by the X-ray plasma and that contains practically all of the X-ray plasma present in the microflare loop. Taking typical values from the hundreds of microflares measured by Shimizu (1995) (X-ray brightness through the thin aluminum filter approximately 4 x 10(exp 3) DN/s/pixel, lifetime approximately 5 min, temperature approximately 6 x 10(exp 6) K, loop length approximately 10(exp 9) cm, loop diameter approximately 3 x 10(exp 8) cm), we find that for filling factors greater than approximately 1% (1) the cooling time is much shorter than the duration of the microflare, and (2) conductive cooling strongly dominates over radiative cooling. Because the cooling time is so short and because the conductive heat flux goes mainly into increasing the plasma density via chromospheric evaporation, we are compelled to conclude that (1) heating to X-ray temperatures continues through nearly the entire life of a microflare, (2) the heating keeps changing to different field lines, so that any one magnetic tube in the sequence of heated tubes emits X-rays only briefly in the life of the microflare, and (3) at any instant during the microflare the tubes filled with X-ray plasma occupy only a small fraction (less than approximately 10%) of the microflare loop. Hence, we expect that coronal X-ray images with spatial resolution 2-3 times better than from Yohkoh will show plenty of rapidly changing filamentary substructure in microflares.

Moore, Ronald L.↗

North Slope of Alaska XSAPR b1 Data Processing Report: May 2025-April 2026

The U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) User Facility operates an X-band Scanning ARM Precipitation Radar (XSAPR) at the North Slope of Alaska (NSA) atmospheric observatory in Utqiaġvik. This radar provides year-round dual-polarization measurements of snow and ice in an arctic environment. Over the past few years, there has been greater focus on the NSA XSAPR, and recent efforts by ARM staff have resulted in quality-controlled, b-level data (Rocque et al. 2026b). This report outlines the processing of the second set of b-level data released for this radar from May 2025 through April 2026 following similar methods from Rocque et al. (2026b).

54 ENVIRONMENTAL SCIENCES↗

Radiation-Induced Solid-State Transformations of Uranyl Peroxides

Single-crystal X-ray diffraction studies of pristine and γ-irradiated Ca 2 [UO 2 (O 2 ) 3 ]·9H 2 O reveal site-specific atomic-scale changes during the solid-state progression from a crystalline to X-ray amorphous state with increasing dose. Following γ-irradiation to 1, 1.5, and 2 MGy, the peroxide group not bonded to Ca 2+ is progressively replaced by two hydroxyl groups separated by 2.7 Å (with minor changes in the unit cell), whereas the peroxide groups bonded to Ca 2+ cations are largely unaffected by irradiation prior to amorphization, which occurs by a dose of 3 MGy. The conversion of peroxide to hydroxyl occurs through interaction of neighboring lattice H 2 O molecules and ionization of the peroxide O–O bond, which produces two hydroxyls, and allows isolation of the important monomer building block, UO 2 (O 2 ) 2 (OH) 2 4– , that is ubiquitous in uranyl capsule polyoxometalates. Steric crowding in the equatorial plane of the uranyl ion develops and promotes transformation to an amorphous phase. In contrast, γ-irradiation of solid Li 4 [(UO 2 )(O 2 ) 3 ]·10H 2 O results in a solid-state transformation to a well-crystallized peroxide-free uranyl oxyhydrate containing sheets of equatorial edge and vertex-sharing uranyl pentagonal bipyramids with likely Li and H 2 O in interlayer positions. The irradiation products of these two uranyl triperoxide monomers are compared via X-ray diffraction (single-crystal and powder) and Raman spectroscopy, with a focus on the influence of the Li + and Ca 2+ countercations. Highly hydratable and mobile Li+ yields to uranyl hydrolysis reactions, while Ca 2+ provides lattice rigidity, allowing observation of the first steps of radiation-promoted transformation of uranyl triperoxide.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The X-ray superbubble in Cygnus

It is shown that Cyg X-6 and Cyg X-7 are part of a large X-ray ring, 13 degrees in diameter. At a distance of 2 kpc, this X-ray source lies behind the Great Rift of Cygnus, and as such has radiation from its central region absorbed. The diameter of the emitting region is 450 pc. The X-ray source is associated with a ring of elongated H-alpha filaments which enclose the Cygnus X radio source. At the center of this region lies the highly luminous Cygnus OB2 association.

Cash, W.↗

A perspective on the device physics of lead halide perovskite semiconducting detector for gamma and x-ray sensing

Metal-halide perovskites are emerging materials for radiation sensing featuring high absorption cross section, high charge mobility, and long carrier lifetime enabling superior detection efficiencies even at room temperature. Perovskite detector technologies are more complex involving different detecting modes and device architectures. Here, to elucidate the working principles, we provide a Perspective on the device structures and the operational principles of halide perovskite direct conversion detectors for radiation sensing. We will first discuss different detection modes and introduce the commonly used device architectures and their working principles. Based on our work and pioneer developments in the field, we will next compare the performances of the reported detectors. Additionally, we will summarize the single crystal detectors and polycrystalline thin film devices and discuss their advantages and disadvantages for different applications. Finally, we provide a future Perspective on the critical problems that must be addressed to commercialize this technology.

77 NANOSCIENCE AND NANOTECHNOLOGY↗