Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Window”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Near-infrared spectroscopy for burning plasma diagnostic applications

Ultraviolet and visible (UV-VIS, 200-750 nm) atomic spectroscopy of neutral and ionized fuel species (H, D, T, and Li) and impurities (e.g., He, Be, C, and W) is a key element of plasma control and diagnosis on International Thermonuclear Experimental Reactor and future magnetically confined burning plasma experiments (BPXs). Spectroscopic diagnostic implementation and performance issues that arise in the BPX harsh nuclear environment in the UV-VIS range, e.g., degradation of first mirror reflectivity under charge-exchange atom bombardment (erosion) and impurity deposition, permanent and dynamic loss of window, and optical fiber transmission under intense neutron and {gamma}-ray fluxes, are either absent or not as severe in the near-infrared (NIR, 750-2000 nm) range. An initial survey of NIR diagnostic applications has been undertaken on the National Spherical Torus Experiment. It is demonstrated that NIR spectroscopy can be used for machine protection and plasma control applications, as well as contribute to plasma performance evaluation and physics studies. Emission intensity estimates demonstrate that NIR measurements are possible in the BPX plasma operating parameter range. Complications in the NIR range due to the parasitic background emissions are expected to occur at very high plasma densities, low impurity densities, and at high plasma-facing component temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pilot Quality Control Program for Audit RT External Beams at Mexican Hospitals

A pilot quality control program for audit 18 radiotherapy RT external beams at 13 Mexican hospitals is described--for eleven {sup 60}Co beams and seven photon beams of 6, 10 and 15 MV from accelerators. This program contains five parts: a) Preparation of the TLD-100 powder: washing, drying and annealing (one hour 400 deg. C plus 24 hrs 80 deg. C). b) Sending two IAEA type capsules to the hospitals for irradiation at the hospital to a nominal D{sub W} = 2 Gy{center_dot}c) Preparation at the SSDL of ten calibration curves CC in the range of 0.5 Gy to 6 Gy in terms of absorbed dose to water D{sub W} for {sup 60}Co with traceability to primary laboratory NRC (Canada), according to a window irradiation: 26/10/2007-7/12/2007. d) Reading all capsules that match their hospital time irradiation and the SSDL window irradiation. f) Evaluation of the Dw imparted by the hospitals.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonlinear behavior in the time domain in argon atmospheric dielectric-barrier discharges

A vast majority of nonlinear behavior in atmospheric pressure discharges has so far been studied in the space domain, and their time-domain characters are often believed to exact the periodicity of the externally applied voltage. In this paper, based on one-dimensional fluid mode, we study complex nonlinear behavior in the time domain in argon atmospheric dielectric-barrier discharges at very broad frequency range from kilohertz to megahertz. Under certain conditions, the discharge not only can be driven to chaos from time-periodic state through period-doubling bifurcation, but also can return stable periodic motion from chaotic state through an inverse period-doubling bifurcation sequence. Upon changing the parameter the discharge undergoes alternatively chaotic and periodic behavior. Some periodic windows embedded in chaos, as well as the secondary bifurcation occurring in the periodic windows can also be observed. The corresponding discharge characteristics are investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of intense coherent synchrotron radiation at frequencies around 0.1 THz using the compact S-band linac

We measured intense radiation from an electron bunch in a millimeter wave region using the compact S-band linac. The dependence of the radiation on the electron-bunch charge was measured with an rf detector system at frequencies around 0.1 THz and was confirmed to be a coherent synchrotron radiation (CSR). The total power of the horizontally and vertically polarized CSRs, which were extracted through the Z-cut quartz window within 1 ns, was calculated to be about 88 and 30 nJ/pulse, excluding the absorption by the window. The two-dimensional distribution of the vertically polarized CSR was measured at a distance of about 0.7 m from the radiation point. The CSR distribution was comparatively uniform in the horizontal plane. Intense CSR, which was reflected in the vacuum chamber, was extracted with a delay of about 6 ns. This suggests that measurement of temporal structure is needed for CSR applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Demonstration of the shock-timing technique for ignition targets on the National Ignition Facility

A high-performance inertial confinement fusion capsule is compressed by multiple shock waves before it implodes. To minimize the entropy acquired by the fuel, the strength and timing of those shock waves must be accurately controlled. Ignition experiments at the National Ignition Facility (NIF) will employ surrogate targets designed to mimic ignition targets while making it possible to measure the shock velocities inside the capsule. A series of experiments on the OMEGA laser facility [Boehly et al., Opt. Commun. 133, 495 (1997)] validated those targets and the diagnostic techniques proposed. Quartz was selected for the diagnostic window and shock-velocity measurements were demonstrated in Hohlraum targets heated to 180 eV. Cryogenic experiments using targets filled with liquid deuterium further demonstrated the entire timing technique in a Hohlraum environment. Direct-drive cryogenic targets with multiple spherical shocks were used to further validate this technique, including convergence effects at relevant pressures (velocities) and sizes. These results provide confidence that shock velocity and timing can be measured in NIF ignition targets, allowing these critical parameters to be optimized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved reliability of Mo nanocrystal memory with ammonia plasma treatment

We investigated ammonia plasma treatment influence on the nonvolatile memory characteristics of the charge storage layer composed of Mo nanocrystals embedded in nonstoichiometry oxide (SiO{sub x}). X-ray photoelectron spectra analyses revealed that nitrogen was incorporated into the charge storage layer. Electric analyses indicated that the memory window was reduced and the retention and the endurance improved after the treatment. The reduction in the memory window and the improvement in retention were interpreted in terms of the nitrogen passivation of traps in the oxide around Mo nanocrystals. The robust endurance characteristic was attributed the improvement of the quality of the surrounding oxide by nitrogen passivation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of photodisintegration reactions for the p-process reaction network

In the last years, a large number of photoneutron reactions in the astrophysically relevant energy window just above the neutron emission threshold has been studied in photoactivation experiments at the superconducting Darmstadt electron linear accelerator S-DALINAC. The experimental results are discussed with regard to their astrophysical implications and compared with two statistical model calculations.Complementary experiments on (p,{gamma}) and ({alpha},{gamma}) reactions of astrophysical interest for the p process are planned for the next years at the Cologne TANDEM ion accelerator. We report on a first test experiment studying the proton capture reaction {sup 74}Ge(p,{gamma}){sup 75}As at energies within the astrophysically relevant Gamow window.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for Very Short Bursts with the AGILE Mini-Calorimeter

In this paper the results of the first months of burst search on very short time scales with the Mini-Calorimeter (MCAL) on-board the AGILE mission are presented. MCAL is equipped with a flexible on-board trigger logic for autonomous GRB detection. In addition to standard trigger time windows, MCAL has been equipped with trigger capabilities on 16 ms, 1 ms and sub-millisecond time windows. Since June 2008 burst search on these short time scales has been enabled, resulting in an average rate of 4 triggers/orbit, compliant with telemetry budget. An on-ground rejection strategy is applied, allowing more sophisticated selection criteria than those allowed by the on-board trigger logic. Triggers due to instrumental effects or geophysical phenomena can be spotted due to their photon-by-photon pattern; what remains after this cleaning is an almost unexplored territory and could shed light on the origin of very short bursts. The trigger criteria, as well as the on-ground rejection strategy and the properties of the selected events will be described and discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Tuning of electrical charging effects for ferromagnetic Mn-doped ZnO nanocrystals embedded into a SiO{sub 2} layer fabricated by KrF excimer laser irradiation

The ZnMnO nanocrystals were formed by the laser irradiation of the sputter-deposited ZnMnO ultrathin layer using a 248 nm KrF excimer laser, and the size and density of the nanocrystals were observed to be controllable by modulations of either the energy density or the frequency of the irradiated pulsed-laser beam. Metal-oxide-semiconductor capacitors fabricated using ZnMnO nanocrystals clearly showed the electrical charging effect, and it was observed that the memory window depends on the size and density of nanocrystals. For measurements of the spontaneous magnetization, ZnMnO nanocrystals showed to have room-temperature ferromagnetism with M{sub r} of approx1.5 emu/cm{sup 3} and H{sub c} 167 Oe. By using ferromagnetism in ZnMnO nanocrystals, tuning of the memory window was demonstrated. Namely, it was clearly observed that the flat-band voltage shift of approx1.25 V can be modulated to be approx0.8 V by applying the magnetic field. This is attributed to the modulation of probabilities for tunneling events due to the increased magnetoelectrical repulsion between spin-polarized carriers in ZnMnO dilute magnetic semiconductor nanocrystals and unpolarized carriers in p-Si under the magnetic field. These results suggest that ZnMnO nanocrystals can be used for spin-functional memory devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Radio frequency-driven proton source with a back-streaming electron dump

This article describes an rf ion source with a back-streaming electron dump. A quartz tube, brazed to a metal plug at one end, is fused in the center of a flat quartz plate. rf power (at 13.6 MHz) is coupled to generate hydrogen plasma using a planar external antenna bonded to the window. Bonding the water-cooled rf antenna to the quartz window significantly lowers its temperature. The water-cooled metal plug serves as the back-streaming electron dump. At 1800 W, the current density of extracted hydrogen ions reaches approximately 125 mA/cm{sup 2}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Formation and conversion of defect centers in low water peak single mode optical fiber induced by gamma rays irradiation

The formation and conversion processes of defect centers in low water peak single mode optical (LWPSM) fiber irradiated with gamma rays were investigated at room temperature using electron spin resonance. Germanium electron center (GEC) and self-trapped hole center (STH) occur when the fibers are irradiated with 1 and 5 kGy cumulative doses, respectively. With the increase in irradiation doses, the GEC defect centers disappear, and new defect centers such as E{sup '} centers (Si and Ge) and nonbridge oxygen hole centers (NBOHCs) generate. The generation of GEC and STH is attributed to the electron transfer, which is completely balanced. This is the main reason that radiation-induced attenuation (RIA) of the LWPSM fiber is only 10 dB/km at communication window. The new defect centers come from the conversion of GEC and STH to E{sup '} centers and NBOHC, and the conversion processes cause bond cleavage, which is the root cause that the RIA of the LWPSM fiber significantly increases up to 180 dB/km at working window. Furthermore, the concentration of new defect centers is saturated easily even by increasing cumulative doses.

36 MATERIALS SCIENCE↗

INDEX OF REFRACTION OF SHOCK LOADED SODA-LIME GLASS

Soda-lime glass (SLG) is a potential low-cost VISAR window for use at moderate shock pressures (up to 2430 GPa) where the material remains transparent. In order for SLG to be practical as a VISAR window, the correction factor, which describes the frequency correction related to the strain dependence of the refractive index, and hence the index of refraction itself, must be characterized as a function of pressure. Characterization data are reported in this paper and compared to previous results. The present data show good agreement with those of Dandekar [J. Appl. Phys. 84, 6614 (1998)] and separate study results by Gibbons and Ahrens [J. Geophys. Res. 76, 5489 (1971)] up to 7 GPa. However, at stresses over 7 GPa, marked discrepancies are evident between the present data and that of Gibbons and Ahrens. Differences in test methods may explain these discrepancies.

36 MATERIALS SCIENCE↗

Numerical simulations of high power microwave dielectric interface breakdown involving outgassing

With the development of high power microwave (HPM) technology, the power and pulse duration of the HPM source increase substantially, the breakdown of the dielectric window of the HPM source feed has been becoming the major factor of limiting the transmission and radiation of HPM. This paper presents an electrostatic particle-in-cell and Monte Carlo collisions method for simulating the breakdown on HPM dielectric surface and establishes a physical model of HPM dielectric surface breakdown involving outgassing. The breakdown process including the main physical mechanisms, such as the field emission, multipactor, outgassing, and collision of gas ionization, is simulated. The influence of outgassing on the dielectric window breakdown is studied by simulating the breakdown with different outgassing speeds. The similarity between the dc and HPM dielectric surface breakdown is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Dose That Works: Low Level Laser Treatment of Tendinopathy

Background: Low Level Laser Therapy (LLLT) is used in the treatment of tendon injuries. However, the clinical effectiveness of this modality remains controversial with limited agreement on the most efficacious dosage and parameter choices. Purpose: To assess the clinical effectiveness of LLLT in the treatment of tendinopathy and the validity of current dosage recommendations for treatment. Method: Medical databases were searched from inception to 1st August 2008. Controlled clinical trials evaluating LLLT as a primary intervention for any tendinopathy were included in the review. Methodological quality was classified using the PEDro scale. Appropriateness of treatment parameters were assessed using established guidelines. Results: Twenty five trials met the inclusion criteria. There was conflicting findings from multiple trials: 12 showed positive effects and 13 were inconclusive or showed no effect. Dosages used in the 12 positive studies support the existence of an effective dosage window that closely resembled current guidelines. Where pooling of data was possible, LLLT showed a positive effect size; in high quality studies of lateral epicondylitis, participants' grip strength was 9.59 Kg higher than the control group; for participants with Achilles tendinopathy, the effect was 13.6 mm less pain on a 100 mm visual analogue scale. Conclusion: This study found conflicting evidence as to the effectiveness of LLLT in the treatment of tendinopathy. However, an effective dosage window emerged showing benefit in the treatment of tendinopathy. Strong evidence exists from the 12 positive studies that positive outcomes are associated with the use of current dosage recommendations for the treatment of tendinopathy.

60 APPLIED LIFE SCIENCES↗

Improved time-frequency analysis of ASDEX Upgrade reflectometry data using the reassigned spectrogram technique

The spectrogram is one of the best-known time-frequency distributions suitable to analyze signals whose energy varies both in time and frequency. In reflectometry, it has been used to obtain the frequency content of FM-CW signals for density profile inversion and also to study plasma density fluctuations from swept and fixed frequency data. Being implemented via the short-time Fourier transform, the spectrogram is limited in resolution, and for that reason several methods have been developed to overcome this problem. Among those, we focus on the reassigned spectrogram technique that is both easily automated and computationally efficient requiring only the calculation of two additional spectrograms. In each time-frequency window, the technique reallocates the spectrogram coordinates to the region that most contributes to the signal energy. The application to ASDEX Upgrade reflectometry data results in better energy concentration and improved localization of the spectral content of the reflected signals. When combined with the automatic (data driven) window length spectrogram, this technique provides improved profile accuracy, in particular, in regions where frequency content varies most rapidly such as the edge pedestal shoulder.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Colliding Laser Pulses for Laser-Plasma Accelerator Injection Control

Decoupling injection from acceleration is a key challenge to achieve compact, reliable, tunable laser-plasma accelerators (LPA). In colliding pulse injection the beat between multiple laser pulses can be used to control energy, energy spread, and emittance of the electron beam by injecting electrons in momentum and phase into the accelerating phase of the wake trailing the driver laser pulse. At LBNL, using automated control of spatiotemporal overlap of laser pulses, two-pulse experiments showed stable operation and reproducibility over hours of operation. Arrival time of the colliding beam was scanned, and the measured timing window and density of optimal operation agree with simulations. The accelerator length was mapped by scanning the collision point.

43 PARTICLE ACCELERATORS↗

Investigation of the delay time distribution of high power microwave surface flashover

Characterizing and modeling the statistics associated with the initiation of gas breakdown has proven to be difficult due to a variety of rather unexplored phenomena involved. Experimental conditions for high power microwave window breakdown for pressures on the order of 100 to several 100 torr are complex: there are little to no naturally occurring free electrons in the breakdown region. The initial electron generation rate, from an external source, for example, is time dependent and so is the charge carrier amplification in the increasing radio frequency (RF) field amplitude with a rise time of 50 ns, which can be on the same order as the breakdown delay time. The probability of reaching a critical electron density within a given time period is composed of the statistical waiting time for the appearance of initiating electrons in the high-field region and the build-up of an avalanche with an inherent statistical distribution of the electron number. High power microwave breakdown and its delay time is of critical importance, since it limits the transmission through necessary windows, especially for high power, high altitude, low pressure applications. The delay time distribution of pulsed high power microwave surface flashover has been examined for nitrogen and argon as test gases for pressures ranging from 60 to 400 torr, with and without external UV illumination. A model has been developed for predicting the discharge delay time for these conditions. The results provide indications that field induced electron generation, other than standard field emission, plays a dominant role, which might be valid for other gas discharge types as well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High external quantum efficiency and fill-factor InGaN/GaN heterojunction solar cells grown by NH 3 -based molecular beam epitaxy

High external quantum efficiency (EQE) p-i-n heterojunction solar cellsgrown by NH 3 -based molecular beam epitaxy are presented. EQE values including optical losses are greater than 50% with fill-factors over 72% when illuminated with a 1 sun AM0 spectrum. Optical absorptionmeasurements in conjunction with EQE measurements indicate an internal quantum efficiency greater than 90% for the InGaN absorbing layer. By adjusting the thickness of the top p-type GaN window contact layer, it is shown that the short-wavelength (<365 nm) quantum efficiency is limited by the minority carrier diffusion length in highly Mg-doped p-GaN.

14 SOLAR ENERGY↗