Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ULTRASOUND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Linear Array Ultrasonic Test Results from Alkali-Silica Reaction (ASR) Specimens

The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the various nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations.This report presents results of the ultrasound evaluation of four concrete slabs with varying levels of ASR damage present. This included an investigation of the experimental results, as well as a supplemental simulation considering the effect of ASR damage by elasto-dynamic wave propagation using a finite integration technique method. It was found that the Hilbert Transform Indicator (HTI), developed for quantification of freeze/thaw damage in concrete structures, could also be successfully utilized for quantification of ASR damage. internal microstructure flaws, and reinforcement locations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Light Water Reactor Sustainability Program: Evaluation of Localized Cable Test Methods for Nuclear Power Plant Cable Aging Management Programs

This Pacific Northwest National Laboratory (PNNL) milestone report describes progress to date on the investigation of nondestructive test (NDE) methods focusing particularly on local measurements that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As NPPs consider applying for second, or subsequent, license renewal (SLR) to extend their operating period from 60 years to 80 years, it important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs (AMPs) to assure continued safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program is directed toward the more demanding challenge of assuring the cable function under accident or DBE. Most utilities already have a program associated with their first life extension from 40 to 60 years. Regrettably, there is neither a clear guideline nor a single NDE that can assure cable function and integrity for all cables. Thankfully, however, practical implementation of a broad range of tests allows utilities to develop a practical program that assures cable function to a high degree. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB is a destructive test so the test programs must apply an array of other NDE tests to assure or infer the overall set of cable’s system integrity. These cable NDE programs vary in rigor and methodology. As the industry gains experience with the efficacy of these programs, it is expected that implementation practice will converge to a more common approach. This report addresses the range of local NDE cable tests that are or could be practically implemented in a field test situation. These tests include: visual, infrared thermography, interdigital capacitance, indenter, relaxation time indenter, dynamic mechanical analyzer, infrared/near-infrared spectrometry, ultrasound, and distributed fiber optic temperature measurement.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Technique development for modulus, microcracking, hermeticity, and coating evaluation capability characterization of SiC/SiC tubes

Driven by the need to enlarge the safety margins of nuclear fission reactors in accident scenarios, research and development of accident-tolerant fuel has become an important topic in the nuclear engineering and materials community. A continuous-fiber SiC/SiC composite is under consideration as a replacement for traditional zirconium alloy cladding owing to its high-temperature stability, chemical inertness, and exceptional irradiation resistance. An important task is the development of characterization techniques for SiC/SiC cladding, since traditional work using rectangular bars or disks cannot directly provide useful information on the properties of SiC/SiC composite tubes for fuel cladding applications. At Oak Ridge National Laboratory, experimental capabilities are under development to characterize the modulus, microcracking, and hermeticity of as-fabricated, as-irradiated SiC/SiC composite tubes. Resonant ultrasound spectroscopy has been validated as a promising technique to evaluate the elastic properties of SiC/SiC composite tubes and microcracking within the material. A similar technique, impulse excitation, is efficient in determining the basic mechanical properties of SiC bars prepared by chemical vapor deposition; it also has potential for application in studying the mechanical properties of SiC/SiC composite tubes. Complete evaluation of the quality of the developed coatings, a major mitigation strategy against gas permeation and hydrothermal corrosion, requires the deployment of various experimental techniques, such as scratch indentation, tensile pulling-off tests, and scanning electron microscopy. In addition, a comprehensive permeation test station is being established to assess the hermeticity of SiC/SiC composite tubes and to determine the H/D/He permeability of SiC/SiC composites. This report summarizes the current status of the development of these experimental capabilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Determination of He and D permeability of neutron-irradiated SiC tubes to examine the potential for release due to micro-cracking

Driven by the need to enlarge the safety margins of light water reactors in both design-basis and beyond-design-basis accident scenarios, the research and development of accident-tolerant fuel (ATF) has become an importance topic in the nuclear engineering and materials community. Continuous SiC fiber-reinforced SiC matrix ceramic composites are under consideration as a replacement for traditional zirconium alloy cladding owing to their high-temperature stability, chemical inertness, and exceptional irradiation resistance. Among the key technical feasibility issues, potential failure of the fission product containment due to probabilistic penetrating cracking has been identified as one of the two most critical feasibility issues, together with the radiolysisassisted hydrothermal corrosion of SiC. The experimental capability to evaluate the hermeticity of SiC-based claddings is an urgent need. In this report, we present the development of a comprehensive permeation testing station established in the Low Activation Materials Development and Analysis laboratory at Oak Ridge National Laboratory. Preliminary results for the hermeticity evaluation of un-irradiated monolithic SiC tubes, uncoated and coated SiC/SiC composite tubes, and neutron-irradiated monolithic SiC tubes at room temperature are exhibited. The results indicate that this new permeation testing station is capable of evaluating the hermeticity of SiC-based tubes by determining the helium and deuterium permeation flux as a function of gas pressure at a high resolution of 8.07 x 10 -12 atm-cc/s for helium and 2.83 x 10 -12 atm-cc/s for deuterium, respectively. The detection limit of this system is sufficient to evaluate the maximum allowable helium leakage rate of lab-scale tubular samples, which is linearly extrapolated from the evaluation standard used for a commercial as-manufactured light water reactor fuel rod at room temperature. The un-irradiated monolithic SiC tube is hermetic, as is manifested by the un-detectable deuterium permeation flux at various feeding gas pressures. A large helium leakage rate was detected for the uncoated SiC/SiC composite tube exposed to atmosphere, indicating it is inherently not hermetic. The hermeticity of coated SiC/SiC composite tubes is strongly dependent on the coating materials and the preparation of the substrate SiC/SiC composite samples. To simulate the practical application environment, monolithic CVD SiC tubes were exposed to neutron irradiation at the High Flux Isotope Reactor under high heat flux from the internal surface to the external surface. Although finite element analysis and resonant ultrasound spectroscopy measurement indicated that the combined neutron irradiation and high heat flux gave rise to a high probability of cracking within the sample, the hermeticity evaluation of the tested sample still exhibited gas tightness, emphasizing that SiC cracking is inherently a statistical phenomenon. The developed permeation testing station is capable of measuring the gas permeation flux in the range of interest with full confidence based on the presented results. It is considered a critical pre- /post-irradiation examination technique to characterize SiC-based cladding materials in asreceived and irradiated states to aid the research and development of ATF.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ACCObeam: Acoustic Collimated Ultrasonic Beam

A passive, linear arrangement of a sonic crystal-based apparatus and method including a 1D sonic crystal, a nonlinear medium, and an acoustic low-pass filter, for permitting unidirectional broadband ultrasound propagation as a collimated beam for underwater, air or other fluid communication are described. The signal to be transmitted is first used to modulate a high-frequency ultrasonic carrier wave which is directed into the sonic crystal side of the apparatus.

36 MATERIALS SCIENCE↗

Commercial Opportunity Cancer Imaging Ultrasonics-based methods for cancer imaging & diagnostics

Breast cancer is the most frequently diagnosed cancer in U.S. women and prostate cancer is the second leading cause of cancer death in American men. X-ray mammography is the principal breastcancer screening tool available, but its false positive rate is more than 80%. Prostate-specific antigen (PSA) screening, which measures the level of PSA in a man’s blood, is no longer recommended by the U.S. task force for prostate-cancer screening. Los Alamos National Security (LANS) has developed novel imaging technologies for early-stage cancer detection based on advanced ultrasonic analyses. In particular, Los Alamos has developed ultrasoundwaveform tomography and related super-resolution ultrasound- imaging technologies that can provide significantly improved image resolution and characterization of early-stage cancers and thus potentially save lives.

60 APPLIED LIFE SCIENCES↗

Long Baseline Neutrino Experiment (LBNE) Target Material Radiation Damage from Energetic Protons of the Brookhaven Linear Isotope Production (BLIP) Facility

In search of a low-Z pion production target for the Long Baseline Neutrino Facility (LBNF) of the Deep Underground Neutrino Experiment (DUNE) various grades of graphite were irradiated with 140-180 MeV protons to fluence up to ~6 10 20 cm -2 and irradiation temperatures in the range of 100-200oC. The objective of the irradiation experiment was to assess the radiation induced changes in the graphite onset by its interaction with energetic protons and deduce some measure of performance and survivability under the design conditions of LBNF. A multi-faceted post-irradiation evaluation was conducted to both qualify and quantify the induced material property changes. These studies included dimensional stability and thermal expansion, damage annealing via thermal cycling, high temperature post-irradiation annealing to mimic irradiation at elevated temperatures, stress-strain behavior, oxidation contribution to the postirradiation analysis, potential influence of the argon atmosphere under which irradiation took place, and lattice evolution. Dilatometry-based techniques were coupled with ultrasound-based annealing methodologies as well as DSC and TGA analyses. X-ray diffraction experiments assessed the lattice parameter changes and SEM analyses were used to study the different graphite grade structures. The multi-faceted post-irradiation evaluation, in conjunction with off-beam analyses, revealed some important facts regarding the choice of a graphite grade. Specifically, it was observed that the microstructure of a grade plays an important role in its dimensional stability. X-ray diffraction data indicated variability in basal plane spacing prior to irradiation with POCO d 002 =3.3833 Å, IG-430 d 002 =3.36814 Å and R7650 d 002 =3.37944 Å. Isotropic graphite grades such as POCO and IG-430 are confirmed to undergo microstructural shrinking under irradiation. All four irradiated graphite grades experience irradiation-induced creep leading to increased Young’s modulus with changes as high as 50% that varies with microstructure. X-ray diffraction on irradiated graphite confirmed previously made observations where under both energetic protons as well as fast neutrons of fluence > 5 10 20 cm -2 and at temperatures around 200°C acceleration of the effects on both the micro-and macrostructure is observed. Amongst the irradiated grades POCO graphite showed tendency to increase crystallinity order but also shows turbostratic state resulting from the interaction of its lattice with protons. This report presents and discusses the details of the irradiation experiment and the results of the postirradiation evaluation with main objective the assessment of the applicability and survivability of the selected four graphite grades as high-power accelerators pion production targets where the structural integrity, density reduction, dimensional and physical property stability are of paramount importance.

43 PARTICLE ACCELERATORS↗

Magnetostrictive Cold Spray Sensor Feasibility Assessment

Ultrasound sensors and inspection systems are frequently used to generate acoustic waves in metal structures capable of detecting and characterizing cracks, pits, erosion, inclusions, weld anomalies, and other material and structural features. One significant problem with piezoelectric transducers is the difficulty to achieve good coupling between the transducer and the surface being examined. This is particularly true in harsh conditions with high temperatures, cyclical hot and cold temperatures, highly radioactive fields found near nuclear reactors or spent nuclear fuel, caustic or corrosive fluids, and other extreme environmental conditions, as well as in long-term monitoring applications where repair or replacement of the sensor is difficult or expensive. Typically, coupling between the surface and the transducer is achieved with water, gel, grease, viscous shear coupling material, or pressure, which might not be possible or appropriate for long-term applications in which the impedance -matching materials wear away, evaporate, or simply stop functioning due to changes in surface conditions. Fluid couplings can evaporate or drain away from the transducer-substrate interface; glue- based couplings may foul or fail and are notoriously unreliable at high temperatures and in radioactive environments. This work explores the behavior of a magnetostrictive cold-spray patch that is metallurgically bonded to a stainless steel inspection target surface, and compares it to the performance of a standard adhesively-bonded ferrous-cobalt magnetostrictive strip solution. Cold-spray is a coating process where 10 –100 micron diameter powdered metal is accelerated to Mach 2 to Mach 3 (2–3 × speed of sound) and impacted on the surface to be coated. Each powder particle forms a kinetic bond with the substrate or other coating particles to produce a metallurgically bonded layer. If the powder is nickel or cobalt with high magnetostrictive coefficients, this surface can serve as the base of a magnetostrictive sensor suitable for crack or pitting-damage inspection and monitoring that is not subject to temporal or environmental degradation.

47 OTHER INSTRUMENTATION↗

Development of a Generalized Residual Stress Inversion Technique

Residual stress is a common result of manufacturing processes, but it is one that is often overlooked in design and qualification activities. There are many reasons for this oversight, such as lack of observable indicators and difficulty in measurement. Traditional relaxation-based measurement methods use some type of material removal to cause surface displacements, which can then be used to solve for the residual stresses relieved by the removal. While widely used, these methods may offer only individual stress components or may be limited by part or cut geometry requirements. Diffraction-based methods, such as X-ray or neutron, offer non-destructive results but require access to a radiation source. With the goal of producing a more flexible solution, this LDRD developed a generalized residual stress inversion technique that can recover residual stresses released by all traction components on a cut surface, with much greater freedom in part geometry and cut location. The developed method has been successfully demonstrated on both synthetic and experimental data. The project also investigated dislocation density quantification using nonlinear ultrasound, residual stress measurement using Electronic Speckle Pattern Interferometry Hole Drilling, and validation of residual stress predictions in Additive Manufacturing process models.

42 ENGINEERING↗

EFRC Materials Science of Actinides (Final Report)

The Energy Frontier Research Center Materials Science of Actinides (MSA) conducted basic research from 2009-2019. The scientific personnel and participating institutes changed several times during the evolution of the Center, and in total included 24 senior investigators, four national laboratories, and ten universities. Workforce development was a motivating goal of the university-led Center, which included many undergraduate, graduate, and post-doctoral researchers. The center focused on the actinide elements, which arise from the sequential filling of the 5f electron orbitals. Although the specific themes evolved during the Center’s history, the final research themes were: (1) Nanoscale Cage Clusters, (2) Complex Ceramic and Metallic Materials, and (3) Materials Under Extreme Environments. To date, the Center has produced 254 peer-reviewed journal publications and book chapters that acknowledged only the EFRC funding, and an additional 161 journal publications and book chapters that acknowledged funding from the EFRC and additional sources (a few manuscripts are still in preparation). Broad highlights include: (1) Development of an extensive family of actinide nanomaterials that self-assemble in aqueous solution, an understanding of their formation mechanisms and stabilities, and possible uses in nuclear fuel cycles; (2) Establishment of facilities and methodologies to conduct high-temperature calorimetry on transuranium materials, and extensive thermodynamic-based studies of uranium and thorium compounds important to the nuclear fuel cycle; (3) A vastly improved understanding of the behavior of actinide materials in extreme conditions, including high radiation fields, temperatures, and pressures, as well coupled effects of two or more of these; (4) Development of resonance ultrasound spectroscopy and direct measurement of aging of plutonium alloys.

36 MATERIALS SCIENCE↗

Real-Time Acoustic Analysis of Batteries

The project explored development and commercialization of an acoustical approach to battery diagnostics. The technology has significant potential impacts for battery manufacturing and quality assurance, battery management during operation, and could be an enabler for the second-life battery market. Research was focused on inspecting and analyzing the physical condition of batteries using ultrasound. This consisted of designing and building hardware for gathering high-quality acoustic data, as well as using battery charge-discharge cyclers and temperature chambers to operate and age the batteries. Over the course of the 2-year program, we were able to build our first prototypes that are robust enough to be used by industry partners to evaluate our technology. Using the same prototypes, we also showed preliminary evidence that our acoustic inspection method may have distinct advantages over standard electrical methods in terms of detecting differences in the physical quality of battery cells. The project also expanded the participant’s core capabilities beyond time-of-flight acoustic measurements.

25 ENERGY STORAGE↗

SFAI and Related Technologies

Researchers at Los Alamos have developed Swept-Frequency Acoustic Interferometry (SFAI) a technology that enables businesses to have greater control over their industrial processes, allowing for significantly improved efficiency by giving operators vital composition and flow rate information in real-time. This technology fills the information gap by providing this data non-invasively and at a fraction of the cost of traditional composition meters. SFAI uses engineered ultrasound and advanced signal processing to characterize multiphase flow (e.g., liquids, gasses, multi-phase mixtures) and other flows inside sealed containers and flow pipes. By being both low-cost and non-invasive, this technology is set to disrupt the current oil field monitoring state-of-the-art by providing individual well-level composition data, compared to the multi-well macroscopic information that is currently available. We are seeking a commercialization partner to license the technology or fund us through a Cooperative Research and Development Agreement (CRADA) to a further develop a usable product for commercial purposes.

03 NATURAL GAS↗

Application of electron beam technology to decompose persistent emerging drinking water contaminants: poly- and perfluoroalkyl substances (PFAS) and 1,4-Dioxane

Poly- and perfluoroalkyl substances (PFAS) and 1,4-dioxane are persistent emerging contaminants that are currently under consideration for federal and state-specific regulations in drinking water. Both PFAS and 1,4-dioxane are highly resistant to degradation and are not effectively removed by conventional drinking water treatment systems. Results from the Unregulated Contaminant Monitoring Rule 3 survey showed that >540 sites across the nation are contaminated with both PFAS and 1,4-dioxane. Hence, there is a need to identify technologies that can effectively remove both these contaminants. Water treatment via electron beam (e-beam) has been proven effective at treating a wide range of contaminants, including perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), polychlorinated biphenyls, and trichloroethylene. While the e-beam process is often considered similar to advanced oxidation processes (AOPs), e-beam technology is unique in that it produces both highly oxidizing and reducing species at the same time. The specific objectives of this study were to: (i) determine the effectiveness of 9 MeV electrons provided by the Fermilab’s Accelerator Application Development and Demonstration (A2D2) tool to decompose PFAS and 1,4-dioxane; (ii) assess the formation of byproducts during water treatment; (iii) apply the optimized treatment to field groundwater samples contaminated with PFAS and 1,4-dioxane, and (iv) assess the energy demands for the treatment of these contaminants using e-beam. Results from this study showed that e-beam is effective in treating both 1,4-dioxane and PFAS. Complete degradation of 1,4-dioxane was observed at a dose of 5 kGy for an initial concentration of up to 1 ppm without the need for any sample modification. The electrical energy per order (EEo) for treatment of 1,4-dioxane ranged from 0.46 to 0.72 kWh/m 3 /order and was comparable and even lower, in some cases, than other AOP technologies. Alkaline conditions (pH 13) and low dissolved oxygen concentration (2 mg/L) highly favored the treatment of PFAS by e-beam. Greater than 90% removal of PFOA and PFOS from an initial concentration of 100 to 500 ppb was achieved at a dose of 250 kGy and 500 kGy, respectively, under optimized conditions. The degradation efficiency was not significantly changed when treating other PFAS of fluorinated carbon chain length of 5 to 7 individually at 250 kGy with a removal ranging from 85¬–99% for different compounds. Short chain PFAS (perfluorobutanoate: PFBA and perfluorobutane sulfonate: PFBS) did not degrade under the same conditions at 250 kGy, but 70 to 99% degradation was observed at a higher dose of 1000 kGy. Short chain PFAS (perfluorohexanoate: PFHxA (C5) and perfluoroheptanoate: PFHpA (C6)) were detected after treatment of PFOA, but not after PFOS treatment. Inability to close the mass balance through targeted analysis suggests the presence of other intermediates not detectable by available analytical methods. When treating PFAS mixture containing ten compounds at equimolar concentration of 0.05 µM each, preferential degradation of polyfluorinated compound (6:2 fluorotelomer sulfonate or 6:2 FTS) followed by C8 and C7 compounds was observed as a function of increasing e-beam dose. About 30% degradation of ΣPFAS was observed at 250 kGy and no further removal was observed up to a dose of 1000 kGy. C4 to C6 PFASs showed no degradation, while C3 PFAS (PFBS) showed an increase in concentration by 34% at 1000 kGy due to formation from the breakdown of other long chain PFAS. These results suggested that (a) the reaction kinetics is likely different for different PFAS based on chain length, functional group, and the degree of fluorination of the carbon chain, and (b) there may be intermediates generated from the degradation of 6:2 FTS and C7/C8 compounds that can potentially scavenge hydrated electrons needed for reaction with the untreated PFAS molecules. Treatment of three PFAS-contaminated groundwater samples from two US states showed similar trends as observed in the treatment of equimolar PFAS mixtures. Up to 71% removal of ΣPFAS was achieved in real groundwater samples at 750 kGy and data trend suggested that higher degradation is feasible if higher doses (>1MGy) are applied to treat field samples to overcome matrix effects and competing species. Calculated EEo for PFAS ranged from as low as ~48 to 1081 kWh/m 3 /order depending on the type of PFAS treated. These values are comparable and even lower, in some cases, than other destructive technologies employed for PFAS treatment such as ultrasound, plasma, and photochemical treatment. The results from this study indicate e-beam is a promising approach under favorable conditions and should be explored further as an end-of-train treatment option for PFAS destruction.

1,4-Dioxane↗

Ultrasonic Characterization of Ethylene Vinyl Acetate (EVA) Crosslinking for Quality Assurance and Lamination Process Control (US-Xlink)

Module makers strive to cut lamination processing times to enhance production throughput and reduce costs. If overdone, this might lead to poor EVA quality due to incomplete EVA crosslinking and a large concentration of potentially harmful reactants. Those deficiencies are frequently missed during production quality testing as initially their impact on power output is small. Additionally, the crosslinking agent is frequently inhomogeneously dispersed across the EVA foils such that local destructive characterization procedures such as differential scanning calorimetry (DSC), Soxhlet extraction, swelling methods, or mechanical tests provide only a limited amount of information. However, these defects and inhomogeneities can become considerably more important during field operation, dramatically reducing long-term power yield, and increasing LCOE. Examples of typical long-term module degradation modes relating to poor lamination process conditions include cell breakage, corrosion of the metallization, delamination, and local quality deficiencies. To provide reliable material characterization in a manufacturing setting, we devised a non-destructive technology that uses ultrasound to evaluate the quality of interface adhesion and the degree of crosslinking. As a calibration reference, DSC measurements were employed. Although the potential of ultrasonic approaches for this purpose has already been noted, those previous methods were generally limited to local qualitative measurements. Furthermore, variations in EVA thickness and temperature had a substantial impact on them. The solution we propose solves these limitations by employing ultrasonic absorption rather than relying solely on sound velocity data.

14 SOLAR ENERGY↗

Passive Ultrasonic Deterrents to Reduce Bat Mortality in Wind Farms (Final Report)

The overall objective of this project was to develop active and passive ultrasonic deterrent concepts to mitigate bat mortality at wind turbines. The research was supported by the US Department of Energy under the contract DE-EE0008731. Novel ultrasonic bat deterrents are investigated in this study. The deterrents are based on the idea of aerodynamic whistles wherein flow-acoustic resonance is used to produce high-amplitude tonal sound at desired ultrasonic frequencies. The deterrents can be grouped into active and passive. The active deterrents/whistles are driven by pressurized air supplied by an external source (e.g., an air compressor). The passive deterrents/whistles are designed to be mounted on wind turbine blades and are “powered” by the energy in the air moving past the rotor blades. Multiple active and passive deterrent ideas are proposed and investigated numerically and experimentally. The computational analysis involves solving the compressible unsteady Reynolds-averaged Navier-Stokes (URANS) equations and coupling the near-field aerodynamic solution with an integral method based on the Ffowcs Williams-Hawkings acoustic analogy to predict ultrasound in the farfield. Experiments are performed in the anechoic chamber at ISU (for the active whistles) and in the Stability wind tunnel at Virginia Tech (for the passive whistles).

17 WIND ENERGY↗

Ultrasonic waveguide reflectometry for quench detection (CRADA Final Report)

Early detection of thermal runaway (quench) is critical for safely operating high-temperature superconductor (HTS) magnets. Voltage-based techniques provide late detection of quenching in HTS, which can lead to magnet burnout and system damage. Various non-voltage quench-detection approaches are therefore investigated nowadays that are based on magnetic, acoustic, and optical sensing. LBNL has been actively developing the quench detection principle based on diffuse ultrasonic wave propagation since 2017 and has demonstrated the approach's viability with several peer-reviewed publications and a patent application. Over the last decade, Etegent, LBNL partner for this proposal and effort, has been developing a sensing technology that utilizes the propagation of stress waves through the solid metallic and nonmetallic waveguides (WG). The method is based on the dependence of materials' elastic properties and the speed of sound on temperature. Compared with optical analog, acoustic WG operates at much lower frequencies, eliminating the need for expensive, complex, highly sensitive receivers and data processing. Etegent proved this technology in many harsh environments, mainly concentrated high-temperature measurements. The initial contact between LBNL and Etegent started in 2020, aiming at combining our knowledge and effort toward developing a viable ultrasound-based quench detection technique for use with HTS magnets. A preliminary study conducted jointly in 2022 found no principle restrictions for expanding the WG technology toward cryogenic temperature operation. The present CRADA work aimed at designing, building, and testing ultrasonic waveguide temperature sensors at relevant cryogenic conditions, and demonstrating this technology's applicability to detecting heating and quenching in High Temperature Superconductor (HTS)-based cables and magnets. The technical objectives of the project included: (1) Design and fabricate ultrasonic WG sensors suitable for cryogenic operation, (2) Test ultrasonic WGs under cryogenic conditions, (3) Determining a suitable way of insulating WGs to prevent ultrasonic leakage while maintaining good thermal contact with the surrounding medium, (4) WG integration and cryogenic test with HTS conductors and HTS magnets, and (5) Design and basic prototyping of a standalone WG-based quench detection system. This project adds value to the present LBNL magnet diagnostics portfolio and enables a breakthrough in addressing the HTS magnet quench detection challenge.

47 OTHER INSTRUMENTATION↗

Indications of flat bands driving the δ to α volume collapse of plutonium

On cooling from the melt, plutonium (Pu) undergoes a series of structural transformations accompanied by a ≈ 28% reduction in volume from its δ phase to its α phase at low temperatures. While Pu’s partially filled 5f -electron shells are known to be involved, their precise role in the transformations has remained unclear. By using calorimetry measurements on α-Pu and gallium-stabilized δ-Pu combined with resonant ultrasound and X-ray scattering data to account for the anomalously large softening of the lattice with temperature, we show here that the difference in electronic entropy between the α and δ phases dominates over the difference in phonon entropy. Rather than finding an electronic specific heat characteristic of broad $f$-electron bands in α-Pu, as might be expected to occur within a Kondo collapsed phase in analogy with cerium, we find it to be indicative of flatter subbands. An important role played by Pu’s 5$f$ electrons in the formation of its larger unit cell α phase comprising inequivalent lattice sites and varying bond lengths is therefore suggested.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In-Process Monitoring and Structural Health Monitoring of Large-Scale Additive Manufacturing Using Acoustic Emission Technique

ORNL collaborated with MISTRAS Group, Inc. to investigate acoustic emission (AE) as a structural health monitoring (SHM) method for large-scale additive manufacturing (AM). Large-scale AM is being adapted as method of producing large structures in a short lead time and cost-effective way. With the growing advancement in AM techniques and application, machine monitoring and part qualification is highly needed. There has been leading research focused on the manufacturing, feedstock material but minimum research on the SHM, defect detection, and nondestructive evaluation (NDE) for AM. Scanning large structure using conventional nondestructive testing (NDT) techniques, such as ultrasound or X-ray, and searching for potential defects can be very time consuming, challenging and cost prohibitive. AE is a passive technique that can be used to monitor and locate defect progression in large structure by distributing group of sensors around the part. This project utilized AE technique and system manufactured/designed by MISTRAS Group to monitor large-scale AM equipment (i.e. Big Area Additive Manufacturing (BAAM) system located at the Oak Ridge National Laboratory – Manufacturing Demonstration Facility (ORNL-MDF) and the printed parts it produces. The AE system provided valuable insight on defect development/progression during and post-printing process.

36 MATERIALS SCIENCE↗