Prototype ultrasonic instrument for quantitative testing

A prototype ultrasonic instrument has been designed and developed for quantitative testing. The complete delivered instrument consists of a pulser/receiver which plugs into a standard oscilloscope, an rf power amplifier, a standard decade oscillator, and a set of broadband transducers for typical use at 1, 2, 5 and 10 MHz. The system provides for its own calibration, and on the oscilloscope, presents a quantitative (digital) indication of time base and sensitivity scale factors and some measurement data.

Lynnworth, L. C.↗

Performance comparison of three normal-shock position sensors for mixed-compression inlets

The performance of three types of normal shock position sensors for supersonic inlets is described. All three sensors determined the shock position from the presence of the large pressure gradient at the normal shock location. The logic means for the three sensors were: (1) electronic, using pressure transducers, (2) fluidic, and (3) direct-coupled pressure switches. The sensors were evaluated in a two-dimensional, Mach 2.7, supersonic inlet having 30-percent internal supersonic area contraction. Both dynamic (from 1 to 80 Hz) and static tests were conducted.

Dustin, M. O.↗

Active transmission isolation/rotor loads measurement system

Modifications were incorporated into a helicopter active transmission isolation system to provide the capability of utilizing the system as a rotor force measuring device. These included; (1) isolator redesign to improve operation and minimize friction, (2) installation of pressure transducers in each isolator, and (3) load cells in series with each torque restraint link. Full scale vibration tests performed during this study on a CH-53A helicopter airframe verified that these modifications do not degrade the systems wide band isolation characteristics. Bench tests performed on each isolator unit indicated that steady and transient loads can be measured to within 1 percent of applied load. Individual isolator vibratory load measurement accuracy was determined to be 4 percent. Load measurement accuracy was found to be independent of variations in all basic isolator operating characteristics. Full scale system load calibration tests on the CH-53A airframe established the feasibility of simultaneously providing wide band vibration isolation and accurate measurement of rotor loads. Principal rotor loads (lift, propulsive force, and torque) were measured to within 2 percent of applied load.

Kenigsberg, I. J.↗

Apparatus for recovering matter adhered to a host surface

The development of an apparatus for removing and recovering matter adhered to a host surface is described. The device consists of a pickup head with an ultrasonic transducer adapted to deliver ultrasonic pressure waves against the material. The ultrasonic waves agitate the material and cause its separation from the surface. A vacuum system recovers the material and delivers it to suitable storage containers.

Paik, W. W.↗

Indirect Blood Pressure Measuring Device

Design and performance of a blood pressure recording device for pediatric use are reported. A strain gage transducer with a copper-beryllium strip as force sensing element is used to monitor skin movements and to convert them into electrical signals proportional to those displacements. Experimental tests with this device in recording of force developed above the left femoral artery of a dog accurately produced a blood pressure curve.

Hum, L.↗

Noncontacting devices to indicate deflection and vibration of turbopump internal rotating parts

The research is reported which was conducted to develop devices for measuring vibrations and deflections of parts, such as impellers, shafts, turbine wheels, and inducers in operating turbopumps. Three devices were developed to the breadboard stage: ultrasonic Doppler transducer, flash X-rays, and light-pipe reflectance. It was found that the X-ray technique is applicable to the shaft assembly and the turbine seal of the J-2 pump, and the light-pipe-reflectance device appears to be ideal for cryogenic pump sections.

Hamilton, D. B.↗

A potential means of using acoustic emission for crack detection under cyclic-load conditions

A preliminary investigation was conducted to assess the feasibility of monitoring acoustic emission signals from fatigue cracks during cyclic bend tests. Plate specimens of 6A1-4V titanium, 2219-T87 aluminum, and 18-Ni maraging steel were tested with and without crack starter notches. It was found that significant acoustic emission signals could be detected in the frequency range from 100 kHz to 400 kHz. Cracks emanating from starter notches were monitored by the ultrasonic pulse-echo technique and periodically measured by micro-optical examination. Methods used to reduce the effects of extraneous noises (i.e., machine noises, fretting) are described. A frequency spectrum analyzer was used to characterize the emissions and to evaluate methods used to acquire the signals (i.e., transducer location, bandwidth selection). The investigation indicated that it was possible to extract meaningful acoustic emission signals in a cyclic bend machine environment.

Vary, A.↗

Long life assurance study for manned spacecraft long life hardware. Volume 3: Long life assurance studies of components

The guidelines for selecting hardware to be used in manned spacecraft to obtain a five year operational lifetime without maintenance were developed. An analysis was conducted on the design, application, failure mechanisms, manufacturing processes and controls, screen and burn-in techniques, and quality control of hardware items. The equipment considered for evaluation include: (1) electric motors and bearings; (2) accelerometers; (3) gyroscopes and bearings; (4) compressors and pumps, (5) magnetic tape recorders; (6) plumbing components and tubing; (7) check valves; (8) pressure regulators and solenoid valves; (9) thermal control valves; (10) pressure vessels and positive expulsion devices; (11) nickel cadmium batteries; and (12) transducers.

Source record↗

Parametric performance characteristics and treatment of temperature coefficients of silicon solar cells for space application

The electrical performance characteristics of 2 and 10 ohms-cm N/P-type silicon solar cells were measured at simulated solar intensities of 5, 50, 100, 140, 250, 400, 550, 700, and 850 mW/sq cm. At each intensity, the temperature was varied in increments of 20 deg between extremes of +160 and -160 C. Short-circuit current, open-circuit voltage, and maximum power are presented in graphical format. Also described are three methods for predicting solar cell electrical performance as a function of temperature and intensity. Two of the methods are suitable for use at extreme temperature-intensity conditions. These methods were used sucessfully to predict the performance of the transducer on board the Mariner Mars 1971 spacecraft.

Patterson, R. E.↗

The restoration of obliterated stamped serial numbers by ultrasonically induced cavitation in water

Seventeen out of 21 obliterated stamped serial numbers on test specimens of copper, brass, steel, and aluminum were successfully restored. Cavitation induced in water by a piezoelectric transducer was the mechanism used. Primarily, smeared metal was removed from the number grooves by the force of the cavitation, however, numbers were also restored at depths at or below the level of the stamped grooves. The feasibility of this technique as a low cost tool for crime laboratories has been clearly demonstrated. The technique is applicable to a variety of materials, and no previous surface or chemical treatments are necessary.

Young, S. G.↗

The design and development of an automatic control system for the in-duct cancellation of spinning modes of sound

The reduction is discussed of the discrete tones generated by jet engines which is essential for jet aircraft to meet present and proposed noise standards. The discrete tones generated by the blades and vanes propagate in the inlet and exhaust duct in the form of spiraling acoustic waves, or spinning modes. The reduction of these spinning modes by the cancellation effect of the combination of two acoustic fields was investigated. The spinning mode synthesizer provided the means for effective study of this noise reduction scheme. Two sets of electrical-acoustical transducers located in an equally-spaced circular array simultaneously generate a specified spinning mode and the cancelling mode. Analysis of the wave equation for the synthesizer established the optimum cancelling array acoustic parameters for maximum sound pressure level reduction. The parameter dependence of the frequency ranges of propagation of single, specified circumferential modes generated by a single array, and of effective cancellation of the modes generated by two arrays, was determined. Substantial sound pressure level reduction was obtained for modes within these limits.

Harrington, W. W.↗

Biaxial stress relaxation in glassy polymers - Polymethylmethacrylate.

Biaxial stress relaxation studies were performed on glassy polymethylmethacrylate in combined torsion-tension strain fields using a specially designed apparatus with exceptionally high stiffness and low cross talk between the torsional and tensile load measuring transducers. It was found that at low strain levels uniaxial tension relaxation is slower than pure torsion relaxation; tensile-component relaxation rates are unaffected by the level of torsional strain; torsional-component relaxation rates decrease as tensile strain is increased; uniaxial tension relaxation rates approach the pure torsion rates at higher strains (about 2%). A phenomenological treatment is presented which shows that relaxation rates can be coupled to the strain fields in which they are observed and yet be consistent with the concepts of linear viscoelasticity and the Boltzmann superposition integral.

Sternstein, S. S.↗

A multichannel electromagnetic flowmeter telemetry system.

An eight-channel biomedical telemetry system provides four channels of blood flow measurements in addition to blood-pressure and EKG data. Emphasis is placed on the amplifiers and signal conditioning circuitry required for interfacing of the electromagnetic flow transducers with the transmission and modulation subsystems. The large number of data channels permits measurement of flow distribution as well as total cardiac output. The batteries and electronics for four channels (blood flow) weigh about 500 g and have a volume of 250 cu cm.

Fryer, T. B.↗

An implantable blood pressure and flow transmitter.

A miniature totally implantable FM/FM telemetry system has been developed to simultaneously measure blood pressure and blood flow, thus providing an appreciation of the hemodynamics of the circulation to the entire body or to a particular organ. Developed for work with animal subjects, the telemetry system's transmission time is controlled by an RF signal that permits an operating life of several months. Pressure is detected by a miniature intravascular transducer and flow is detected by an extravascular interferometric ultrasonic technique. Both pressure and flow are calibrated prior to implanting. The pressure calibration can be checked after the implanting by cannulation; flow calibration can be verified only at the end of the experiment by determining the voltage output from the implanted sensing system as a function of several measured flow rates. The utility of this device has been established by its use in investigating canine renal circulation during exercise, emotional encounters, administration of drugs, and application of accelerative forces.

Rader, R. D.↗

Design and construction of a reverberation chamber for high-intensity acoustic testing.

A high-intensity acoustic test facility was constructed at the Jet Propulsion Laboratory (JPL) to support the Mariner Mars 1971 project. For ease of construction, the reverberation chamber itself is rectangular, which resulted in very little sacrifice in acoustic performance. Levels as high as 156 dB can be achieved with the chamber empty and test levels of 150 dB have been used with a Mariner Mars spacecraft model (full size) in the chamber. Levels as high as this must be generated using electropneumatic transducers, which modulate gaseous nitrogen to this facility.

Slusser, R. A.↗

Compliance measurements.

The uses of compliance measurements in linear fracture mechanics are discussed as a technique for determining the crack-extension force vs load, specimen dimensions, and elastic constants. Some practical examples of application are given, including specimen and transducer descriptions, experimental procedure, instrumentation, calculations, measurement precautions, friction effects, and data reduction. The limitations and advantages of compliance measurements are discussed. It is pointed out that good results can be obtained by the compliance method when its measurement precision is not lower than that required for Young's modulus.

Bubsey, R. T.↗

DONAR - A computer processing system to extend ultrasonic pulse-echo testing.

A dedicated general purpose digital computer has been built on the principle of a sampled-data system to run an ultrasonic subsystem under programmed control. A most significant application is the ability to extract a signal from an interfering background. As illustrated in the paper, a 1 mm diameter transducer was used to measure the diameter of a 2.5 mm OD plastics tube with 0.4 mm wall thickness. Echoes from all four surfaces were displayed and the measurements indicated an uncertainty of less than 0.1 mm.

Lees, S.↗

Time variation in the reaction-zone structure of two-phase spray detonations.

A detailed theoretical analysis of the time-varying detonation structure in a monodisperse spray is presented. The theory identifies experimentally observed reaction-zone overpressures as deriving from blast waves formed therein by the explosive ignition of the spray droplets, and follows in time the motion, change in strength, and interactions of these blast waves with one another, and with the leading shock. The results are compared with experimental data by modeling the motion of a finite-size circular pressure transducer through the theoretical data field in an x-t space.